  • 8/6/2019 Clariion and Symmetrix ion

    1/3

    The AX series is considered the entry-level disk array.

    Currently two models AX4 and the AX150 are available. The AX150 supports up to 12 Serial

    ATA disks with either 250, 500 or 750 GB (1 GB = 109 B) at a throughput of 150 (250 GB

    disks) or 300 MB/s (500, 750 GB disks) and, optionally, NCQ. Supported RAID levels are RAID

    5 (with min. 3 disks) and RAID 1/0 (min. 4 disks). The Fibre Channel connection supports

    transfer speeds of up to 2 Gbit/s (with both AL and SW configurations),iSCSI is physically

    limited to max. 1 Gbit/s. The AX150 is available in four configurations which differ in

    connection and number of controllers.

    The AX4 is the successor of the AX150 and can support up to 60 Serial ATA or Serial Attached

    SCSI disks (with "Expansion Pack"). The base version has only place for 12 disks. Similar to the

    AX150 it is available in iSCSI or Fibre Channel configurations. Opposed to the AX150 the AX4

    supports Fibre Channel transfer speeds of up to 4 Gbit/s.

    Model Connection # of controllers speed # of supported disks

    AX150 FC 2 2 Gbit/s 12

    AX150SC FC 1 2 Gbit/s 12

    AX150i iSCSI 2 1 Gbit/s 12

    AX150iSC iSCSI 1 1 Gbit/s 12

    AX4-5F FC 1 or 2 4 Gbit/s12 (60 with

    "Expansion Pack")

    AX4-5I iSCSI 1 or 2 1 Gbit/s12 (60 with

    "Expansion Pack")

    CX series

    The CX series supports both SATA and Fibre Channel disks. Supported RAID levels are 1/0, 0,

    1, 3, 5, and 6; the disks can be configured into groups with different RAID levels.

    Models of the CX series come in two configurations: Fibre Channel (transfer speeds max. 2

    Gbit/s) and iSCSI (max. 1 Gbit/s). The exception is the CX700, which is FC only. The names of

    the iSCSI models end with an i, e.g.CX500i.

    Model Max. FC hosts Max. disk drives Initial capacityMax. capacity (1

    TB = 1012 B)

    CX300 64 60 365 GB 27 TBCX500 128 120 4 TB 59 TB

    CX700 256 240 4 TB(?) 119 TB

  • 8/6/2019 Clariion and Symmetrix ion

    2/3

    CX3 series

    The CX3 series originally consisted of CX3-20, CX3-40, and CX3-80 models. Later the series

    was refreshed to include the CX3-10 and the 'i' and 'f' identifiers.

    Model Max. FC hosts Max. disk drives Initial capacityMax. capacity (1

    TB = 1012 B)

    CX3-10 64 60 ??? GB 45 TB

    CX3-20 128 120 4 TB 83 TB

    CX3-40 128 240 4 TB(?) 173 TB

    CX3-80 256 480 4 TB(?) 353 TB

    CX4 UltraFlex series

    The CX4 UltraFlex series contains multiple models which differ in the maximum number of

    disks (SATA or Fibre Channel) and the number of iSCSI and FC connections. The PCI Express

    connection between the FC interface and the storage processor allows transfer speeds of up to 4

    Gbit/s, while iSCSI supports speeds of max. 1 Gbit/s. All current[when?] models support RAID 0,

    1, 1/0, 3, 5, and 6; as with the CX series, groups with differing RAID levels can be created.

    Each CX4 array consists of dual redundant hot-swappable components including storage

    processors, mirrored cache and battery backup, as well as redundant power supplies. The CX4

    series supports Fibre Chanel and iSCSI host connectivity.

    Major New Features in the CX4 UltraFlex Series include support for solid state flash drives, 64-

    bit FLARE Operating Environment and PCI-Express based SLIC I/O cards. The CX4-480 and

    CX-960 support fibrechanel solid state flash drives introduced by EMC for the SymmetrixDMX-4 in January 2008. Solid State Flash drives offer a significant performance advantage over

    mechanical drives and provide a new storage tier which EMC calls Tier-0. The new version of

    the FLARE operating environment that ships with the CX4 series includes support for the 64-bit

    Intel Xeon CPUs in the Storage Processors. The CX4 Series is also the first product to use the

    new PCI Express based SLIC I/O cards. The product-agnostic SLIC I/O cards provide more

    flexibility for future upgrades as new technologies become available, such as 8GBit Fibre Chanel

    and 10GBit Ethernet/iSCSI.

    Model Cache

    Front-

    end FCports

    Front-

    endiSCSI

    ports

    Back-

    endports

    Max.

    HAHosts

    Max.

    diskdrives

    Max.capacity

    FlashDrives

    CX4-120 6 GB 4 4 2 128 120 120 TB Yes

    CX4-240 8 GB 4 4 4 256 240 231 TB Yes

    CX4-480 16 GB 8 4 4 256 480 939 TB Yes

    CX4-960 32 GB 8 4 8 512 960 1899 TB Yes

  • 8/6/2019 Clariion and Symmetrix ion

    3/3

    SYMMETRIX

    Platform Comparisons

    Symmetrix

    VMAX

    Symmetrix

    VMAX SE

    Symmetrix

    DMX-4

    Symmetrix

    DMX-4 950

    Maximum

    Drives2400 360 2400 360

    ArchitectureVirtual Matrix

    Architecture

    Virtual Matrix

    Architecture

    Direct Matrix

    Architecture

    Direct Matrix

    Architecture

    Maximum

    Integrated

    Directors

    16 2 N/A N/A

    Connection

    Types

    FC, FICON,

    Gigabit Ethernet,

    iSCSI

    FC, FICON,

    Gigabit Ethernet,

    iSCSI

    FC, FICON,

    ESCON, Gigabit

    Ethernet, iSCSI

    FC, Gigabit

    Ethernet, iSCSI

    Maximum

    Connectivity

    Up to 128 ports

    depending on

    connection type

    Up to 16 ports

    depending on

    connection type

    Up to 64 ports

    depending on

    connection type

    Up to 16 ports

    depending on

    connection type

    Maximum

    SRDF Ports

    32 (FC or GbE

    SRDF ports)

    4 (FC or GbE

    SRDF ports)

    8 (GbE SRDF

    ports)

    8 (GbE SRDF