class ii modular vault system (6) sided used ......class ii - 60 minute total vault panel weight per...
TRANSCRIPT
![Page 1: CLASS II MODULAR VAULT SYSTEM (6) SIDED USED ......CLASS II - 60 MINUTE TOTAL VAULT PANEL WEIGHT PER SQUARE FOOT: SECTION / ELEVATION "A" 1 1 2 4 ") 4 1 (3 '-8 WIDTH X DEPTH WALL WITH](https://reader035.vdocument.in/reader035/viewer/2022071412/61083216b204d138e4784591/html5/thumbnails/1.jpg)
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 1 O
F 4
L1352
CALL 1-800-999-3600
FREE SPAN VAULT SIZES ( INSIDE DIMENSIONS )
WA
LL O
PE
NIN
GC W
ALL O
PE
NIN
GL
VAULT PLAN
A
WA
LL O
PE
NIN
G
SPECIFICATIONS:PANEL CONSTRUCTION:
PANEL CONNECTIONS:
PANEL THICKNESS:
COMPRESSIVE STRENGTH:10,000 PSI
UL LISTINGS:CLASS II - 60 MINUTE
TOTAL VAULT PANEL WEIGHT PER SQUARE FOOT:
SECTION / ELEVATION "A"
1124
")4
1(3'-8
WIDTH X DEPTH WALL WITH VAULT DOOR OPENING.
PERPENDICULAR ) TO THE VAULT
FLOOR PANELS RUN ( PARALLEL OR
SPECIFY DIRECTION CEILING AND
PERPENDICULAR
PARALLEL
CENTERLINE
SPECIFY
INSIDE WIDTH
SPECIFY
INSIDE DEPTH
SPECIFY
DEPTH
OUTSIDE
WIDTH
OUTSIDE
INSIDE HEIGHT
SPECIFY
0 0
0
0
OUTLINE OF FLOOR RECESS ( BY OWNER'S G.C.)
OU
TLIN
E O
F F
LO
OR R
EC
ES
S ( B
Y O
WN
ER'S G.C.)
2111
")8
1(6'-11
(11")
280
(4'-5")
1347
(4")
102
(4")
102
(4")
102
(4")
102
2261mm (7'-5")
MINIMUM HEIGHT WITH DOOR
2591mm (8'-6") STANDARD HEIGHT
VAULT DOOR SILL PANEL
IN CEILING PANEL
CONDUITS
(6) 25mm (1")
178mm (7")
ALL FOUR SIDES (TYPICAL FOR ANY SIZE VAULT)
ALLOW A MIN. OF 102mm (4") CLEARANCE ON
(BY THE OWNER'S G.C.) FOR INSTALLATION.
") DEEP FLOOR RECESS43OUTLINE OF 197mm (7
INSIDE DEPTH + 355mm (1'-2")
INSIDE WIDTH + 355mm (1'-2")
MINIMUM DISTANCE 914mm (3'-0")
CENTERLINE FROM LEFT INSIDE WALL.
LOCATION OF VAULT DOOR OPENING
ON PAGE 2 OF 4
SEE DETAIL "B"
ENCLOSED WITHIN AN ELECTROSTATIC COATED METAL FRAME.
COMBINATION OF CONCRETE PRODUCTS AND SECURITY FIBERS
LAP JOINT AND WELDED
AND VAULT DOOR LOCATION.
BASED ON THE MODULAR VAULT WIDTH, DEPTH
THE ACTUAL PANEL SIZES WILL BE DETERMINED
PANEL SIZES SHOWN FOR ILLUSTRATION ONLY.
UP TO 4268mm (14'-0") X VARIABLE DEPTH
VARIABLE WIDTH X UP TO 4268mm (14'-0")
SPECIAL CEILING SUPPORT IS REQUIRED.
THAT REQUIRES SPAN OVER 4268mm (14'-0")
FOR VAULTS WITH WIDTH OR DEPTH DIMENSION
FLOOR AND CEILING ARE INSTALLED.
INSTALLED AFTER THE VAULT WALLS,
VAULT DOOR FRAME AND DOOR TO BE
(A+B+C) - (2479 LBS.) = TOTAL VAULT PANEL WEIGHT
" X 95 LBS. PER SQ. FOOT = 2479 LBS.21 3'-9" X 6'-11
SUBTRACT FOR WALL OPENING:
OUTSIDE WIDTH X OUTSIDE DEPTH X 2 X 95 LBS. PER SQ. FOOT= C
INSIDE HEIGHT X OUTSIDE WIDTH X 2 X 95 LBS. PER SQ. FOOT= B
INSIDE DEPTH X INSIDE HEIGHT X 2 X 95 LBS. PER SQ. FOOT = A
")4
3(7
197
(BY O
WN
ER'S G.C.)
FL
OO
R R
EC
ES
S
ON PAGE 2 OF 4
SEE DETAIL "A"
(7")
178
(7")
178
(7")
178
(7")
178
(7")
178
(7")
178
(7")
178
STANDARD CONDUIT DETAILIN LINE WITH VAULT DOOR CENTERLINE
(FREE SPAN VAULT SIZES)
(6) SIDED USED WITH CLASS II DN VAULT DOOR
CLASS II MODULAR VAULT SYSTEM
CLASS II DN VAULT DOOR WEIGHT: 1928 kg. (4250 LBS)
IN CEILING PANEL
CONDUITS
(6) 25mm (1")
MIN.
WALL PANEL
BY DIEBOLD NIXDORF INSTALLERS
SPACED EVERY 304mm (12") ON CENTER
VAULT WALL PANELS. 51mm (2") WELD
VAULT CEILING PANELS WELDED TO
MIN.
(1'-0")
305
CONDUITS
(6) 25mm (1")
FIL
E N
O. 186-2
47 R
EV. 0
(4")
102
(4")
102
(4")
102
(4")
102
(4")
102
(2")
51
(2")
51
(7")
178
(1'-0")
305
(7")
178
(7")
178
![Page 2: CLASS II MODULAR VAULT SYSTEM (6) SIDED USED ......CLASS II - 60 MINUTE TOTAL VAULT PANEL WEIGHT PER SQUARE FOOT: SECTION / ELEVATION "A" 1 1 2 4 ") 4 1 (3 '-8 WIDTH X DEPTH WALL WITH](https://reader035.vdocument.in/reader035/viewer/2022071412/61083216b204d138e4784591/html5/thumbnails/2.jpg)
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 2 O
F 4
MODULAR VAULT APPLICATIONSGENERAL SPECIFICATIONS:
WILL BE ACCEPTED IN VAULT SIZING.
VAULT SIZES MUST BE SHOWN IN EVEN INCHES. NO FRACTIONS OF INCHES
NO LIVE LOADS OF ANY KIND ARE PERMITTED ON ANY VAULT CEILING.
COVERED WITH AN APPLIED FINISHING MATERIAL BY PURCHASER.
EXTERIOR EXPOSED SURFACES BE CAULKED AS NECESSARY AND/OR BE
OR CEILING TILE BY PURCHASER. IT IS RECOMMENDED THAT THE
COVERED BY APPLICATION OF WALL COVERING, FLOOR COVERING,
THE INTERIOR SEAMS AND CONNECTING PLATES TO BE CAULKED AND
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
PAST THE SIDE WALL PANELS TO FORM THE OUTSIDE VAULT CORNERS.
PERPENDICULAR PANELS - VAULT FRONT AND REAR WALL PANELS EXTEND
REAR WALL PANELS TO FORM THE OUTSIDE VAULT CORNERS.
PARALLEL PANELS - SIDE WALL PANELS EXTEND PAST THE FRONT AND
OVER 5182mm (17'-0").
STRUCTURAL CALCULATIONS REQUIRED FOR INSIDE HEIGHT OF WALL PANELS
(SPECIFY SPECIAL CONDITIONS THAT MAY APPLY )
0
0
0
OTHER VAULT DOOR (SPECIFY DOOR INFORMATION).
MUST SPECIFY VAULT DOOR MODEL NUMBER.
0
SPRINKLER PENETRATIONS - SPECIFY LOCATION.
*
0
AT INTERVALS OF 2184mm (8'-0").
STRUCTURAL SUPPORT PROVIDED BY PURCHASER MUST BE LOCATED
THE FLOOR PANELS ARE DESIGNED TO CARRY A LIVE LOAD OF 500 LBS PSF.
TO PROVIDE AT LEAST 3,000 P.S.I. (EQUIVALENT TO 6 BAG MIX).
GROUT TO CONSIST OF CLEAN SAND AND CEMENT USING FORMULATION
AFTER VAULT DOOR IS INSTALLED BY DIEBOLD NIXDORF.
GROUT IN THE SPACE BETWEEN THE FLOOR SILL AND FLOOR RECESS
IT IS "MANDATORY" THAT THE OWNERS GENERAL CONTRACTOR
AND VAULT PANELS WHEN VAULT DOOR IS INSTALLED.
CREATE THE VAULT DOOR OPENING, WELDED TO THE VAULT DOOR
" x 12" STEEL PLATES RUNNING THE FULL HEIGHT AND HEADER 83
THE VAULT DOOR VESTIBULE PANELS ARE STANDARD WALL PANELS.
PANELS RUN.
DESIGN. SEAMS LINE UP ON FLOOR, SIDE WALLS AND CEILING IN DIRECTION
ALL CONNECTIONS ON ALL CLASSES OF VAULTS ARE WELDED LAP JOINT
") MAXIMUM DIAMETER PENETRATIONS 2138mm (1
LARGER THAN 4268mm (14'-0").
VAULTS WITH WIDTH AND DEPTH DIMENSIONS
SPECIAL CEILING SUPPORT IS REQUIRED FOR
THE MAKE-UP PIECE MAY NOT BE NARROWER THAN 305mm (1'-0").
WILL BE USED TO ACHIEVE VAULT SIZES NOT IN MULTIPLES OF 1219mm (4'-0").
UP WALLS, FLOOR AND CEILING. A MAKE-UP PANEL (ONE OR TWO PER SIDE )
ALL CLASS II (6) SIDED VAULTS UTILIZE 1219mm (4'-0") WIDE PANELS TO MAKE
NIXDORF CONTRACT. (6) 25mm (1") CONDUITS PROVIDED IN CEILING PANEL.
PULL ALL ALARM WIRES, TAG AND CONTINUITY TEST UNLESS PART OF DIEBOLD
MAKE ALL ELECTRICAL POWER CONNECTIONS. OWNERS E.C. TO PROVIDE AND
CONDUIT AND JUNCTION BOXES, PROVIDE AND PULL ALL POWER WIRES AND
THE OWNERS ELECTRICAL CONTRACTOR MUST FURNISH AND INSTALL ALL
SEE CUT SHEET FILE NUMBER 186-250
HVAC PORT- SPECIFY LOCATION.
MUST SPECIFY WALL OPENING SIZE.
OF VAULT DOOR OPENING.
SPECIFY LOCATION ON HINGE SIDE OR JAMB SIDE
DN VAULT DOOR IS STANDARD.
VAULT DOOR (STANDARD IN THE DN VAULT DOOR).
VAULT VENTILATOR IN PANEL MAY BE REQUIRED WITH OTHER
AS REQUIRED
AS REQUIRED
PLUS 203mm (8")
EXTERIOR VAULT DEPTH
PLUS 203mm (8")
EXTERIOR VAULT WIDTH
FLOOR RECESS
FLOOR RECESS
") DEEP 43197mm (7
DETAIL "B"
(SEE NOTE 10)
GROUT (BY OWNERS G.C.)
VAULT FLOOR PANEL
(BY O
WN
ER
S G.C.)
FL
OO
R FINIS
H
INSTALLERS
BY DIEBOLD NIXDORF
PANELS WELDED (7
")
178
197 ")4
3(7
RE
CE
SS
FL
OO
R
DETAIL "A"
(SEE NOTE 10)
GROUT (BY OWNERS G.C.)
NOTE:
197 ")4
3(7
SE
E N
OT
E
BY O
WN
ER
S G.C.
FL
OO
R FINIS
H
RE
CE
SS
FL
OO
R
(7")
178
")8
5 (
16
SIL
L P
LA
TE
VA
ULT D
OO
R
DO
OR S
HIM A
S R
EQ
UIR
ED
(1'-8")
508
VAULT DOOR SILL PLATE
DOOR SILL
VAULT PANEL
(11")
280
EXCEED TOP OF SILL PLATE
FEATHERED TO EDGE OF VAULT DOOR SILL HEIGHT, BUT DOES NOT
FLOOR AS REQUIRED SO FINISHED FLOOR HEIGHT MEETS OR IS
APPLIED INSIDE AND OUTSIDE VAULT. OWNER'S G.C. TO PREPARE
OWNER'S G.C. TO VERIFY FLOOR COVERING THICKNESS TO BE
SE
E N
OT
E
BY O
WN
ER
S G.C.
FL
OO
R FINIS
H
FL
OO
R P
AN
EL
MO
DU
LA
R V
AU
LT
(7")
178
VAULT FLOOR PANEL
(VAULT DOOR SILL)
BY OWNER'S G.C.FIL
E N
O. 186-2
47 R
EV. 0
1549
(5'-1")
229
(9")
(4")
102
![Page 3: CLASS II MODULAR VAULT SYSTEM (6) SIDED USED ......CLASS II - 60 MINUTE TOTAL VAULT PANEL WEIGHT PER SQUARE FOOT: SECTION / ELEVATION "A" 1 1 2 4 ") 4 1 (3 '-8 WIDTH X DEPTH WALL WITH](https://reader035.vdocument.in/reader035/viewer/2022071412/61083216b204d138e4784591/html5/thumbnails/3.jpg)
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 3 O
F 4
L1352
CALL 1-800-999-3600FIL
E N
O. 186-2
47 R
EV. 0
FREE SPAN VAULT SIZES ( INSIDE DIMENSIONS )
TOTAL VAULT PANEL WEIGHT PER SQUARE FOOT:
WIDTH X DEPTH WALL WITH VAULT DOOR OPENING.
PERPENDICULAR ) TO THE VAULT
FLOOR PANELS RUN ( PARALLEL OR
SPECIFY DIRECTION CEILING AND
PERPENDICULAR
PARALLEL
C W
ALL O
PE
NIN
GL
VAULT PLAN
A
CENTERLINE
SPECIFY
INSIDE WIDTH
SPECIFY
DEPTH
OUTSIDE
WIDTH
OUTSIDE
INSIDE DEPTH + 355mm (1'-2")
SECTION / ELEVATION "A"
INSIDE HEIGHT
SPECIFY
2112
")8
1(6'-11
1124
")4
1(3'-8
SPECIFICATIONS:PANEL CONSTRUCTION:
PANEL CONNECTIONS:
PANEL THICKNESS:
COMPRESSIVE STRENGTH:10,000 PSI
UL LISTINGS:CLASS II - 60 MINUTE
178mm (7")
ENCLOSED WITHIN AN ELECTROSTATIC COATED METAL FRAME.
COMBINATION OF CONCRETE PRODUCTS AND SECURITY FIBERS
LAP JOINT AND WELDED
MINIMUM DISTANCE 914mm (3'-0")
CENTERLINE FROM LEFT INSIDE WALL.
LOCATION OF VAULT DOOR OPENING
INSIDE WIDTH + 355mm (1'-2")W
ALL O
PE
NIN
G
INSIDE DEPTH
SPECIFY
0 0
WA
LL O
PE
NIN
G
2261mm (7'-5")
MINIMUM HEIGHT WITH DOOR
2591mm (8'-6") STANDARD HEIGHT
IN CEILING PANEL
CONDUITS
(6) 25mm (1")
AND VAULT DOOR LOCATION
BASED ON THE MODULAR VAULT WIDTH, DEPTH
THE ACTUAL PANEL SIZES WILL BE DETERMINED
PANEL SIZES SHOWN FOR ILLUSTRATION ONLY.
SEE DETAIL ON PAGE 4 OF 4
NIXDORF INSTALLERS
TO VAULT WALL PANEL. BY DIEBOLD
ATTACHED TO FLOOR AND WELDED
" ANGLE8351mm (2") X 51mm (2") X
CEILING PANELS.
ALL AROUND TO PLACE WALL AND
51mm (2") INSTALLATION CLEARANCE
AND CEILING ARE INSTALLED.
INSTALLED AFTER THE VAULT WALLS,
VAULT DOOR FRAME AND DOOR TO BE
(A+B+C) - (2479 LBS.) = TOTAL VAULT PANEL WEIGHT
" X 95 LBS. PER SQ. FOOT = 2479 LBS.21 3'-9" X 6'-11
SUBTRACT FOR WALL OPENING:
OUTSIDE WIDTH X OUTSIDE DEPTH X 95 LBS. PER SQ. FOOT= C
INSIDE HEIGHT X OUTSIDE WIDTH X 2 X 95 LBS. PER SQ. FOOT= B
INSIDE DEPTH X INSIDE HEIGHT X 2 X 95 LBS. PER SQ. FOOT = A
UP TO 4268mm (14'-0") X VARIABLE DEPTH
VARIABLE WIDTH X UP TO 4268mm (14'-0")
SPECIAL CEILING SUPPORT IS REQUIRED.
THAT REQUIRES SPAN OVER 4268mm (14'-0")
FOR VAULTS WITH WIDTH OR DEPTH DIMENSION
ON PAGE 4 OF 4
SEE DETAIL "C"
(7")
178
(7")
178
(7")
178
(7")
178
STANDARD CONDUIT DETAILIN LINE WITH VAULT DOOR CENTERLINE
(7")
178
(FREE SPAN VAULT SIZES)
(5) SIDED USED WITH CLASS II DN VAULT DOOR
CLASS II MODULAR VAULT SYSTEM
CLASS II DN VAULT DOOR WEIGHT: 1928kg (4250 LBS)
IN CEILING PANEL
CONDUITS
(6) 25mm (1")
MIN.
WALL PANEL
BY DIEBOLD NIXDORF INSTALLERS
SPACED EVERY 304mm (12") ON CENTER
VAULT WALL PANELS. 51mm (2") WELD
VAULT CEILING PANELS WELDED TO
MIN.
(1'-0")
305
CONDUITS
(6) 25mm (1")
(4")
102
(4")
102
(4")
102
(4")
102
(4")
102
(2")
51
(2")
51
(7")
178
(1'-0")
305
(7")
178
(7")
178
![Page 4: CLASS II MODULAR VAULT SYSTEM (6) SIDED USED ......CLASS II - 60 MINUTE TOTAL VAULT PANEL WEIGHT PER SQUARE FOOT: SECTION / ELEVATION "A" 1 1 2 4 ") 4 1 (3 '-8 WIDTH X DEPTH WALL WITH](https://reader035.vdocument.in/reader035/viewer/2022071412/61083216b204d138e4784591/html5/thumbnails/4.jpg)
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E"
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
PR
OJE
CTIO
N
THIR
D A
NG
LE
(DIM
EN
SIO
NS I
N I
NC
HE
S)
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
PA
GE 4 O
F 4
MODULAR VAULT APPLICATIONS
(SPECIFY SPECIAL CONDITIONS THAT MAY APPLY )
0
0
0
OTHER VAULT DOOR (SPECIFY DOOR INFORMATION).
MUST SPECIFY VAULT DOOR MODEL NUMBER.
0
SPRINKLER PENETRATIONS - SPECIFY LOCATION.
*
0
") MAXIMUM DIAMETER PENETRATIONS. 2138mm (1
LARGER THAN 4268mm (14'-0").
VAULTS WITH WIDTH AND DEPTH DIMENSIONS
SPECIAL CEILING SUPPORT IS REQUIRED FOR
GENERAL SPECIFICATIONS:
WILL BE ACCEPTED IN VAULT SIZING.
VAULT SIZES MUST BE SHOWN IN EVEN INCHES. NO FRACTIONS OF INCHES
1.
2.
3.
4.
5.
6.
7.
8.
PAST THE SIDE WALL PANELS TO FORM THE OUTSIDE VAULT CORNERS.
PERPENDICULAR PANELS - VAULT FRONT AND REAR WALL PANELS EXTEND
REAR WALL PANELS TO FORM THE OUTSIDE VAULT CORNERS.
PARALLEL PANELS - SIDE WALL PANELS EXTEND PAST THE FRONT AND
OVER 5182mm (17'-0").
STRUCTURAL CALCULATIONS REQUIRED FOR INSIDE HEIGHT OF WALL PANELS
NIXDORF CONTRACT. (6) 25mm (1") CONDUITS PROVIDED IN CEILING PANEL
PULL ALL ALARM WIRES, TAG AND CONTINUITY TEST UNLESS PART OF DIEBOLD
MAKE ALL ELECTRICAL POWER CONNECTIONS. OWNERS E.C. TO PROVIDE AND
CONDUIT AND JUNCTION BOXES, PROVIDE AND PULL ALL POWER WIRES AND
THE OWNERS ELECTRICAL CONTRACTOR MUST FURNISH AND INSTALL ALL
AND VAULT PANELS WHEN VAULT DOOR IS INSTALLED.
CREATE THE VAULT DOOR OPENING, WELDED TO THE VAULT DOOR
" x 12" STEEL PLATES RUNNING THE FULL HEIGHT AND HEADER 83
THE VAULT DOOR VESTIBULE PANELS ARE STANDARD WALL PANELS.
NO LIVE LOADS OF ANY KIND ARE PERMITTED ON ANY VAULT CEILING.
COVERED WITH AN APPLIED FINISHING MATERIAL BY PURCHASER.
EXTERIOR EXPOSED SURFACES BE CAULKED AS NECESSARY AND/OR BE
OR CEILING TILE BY PURCHASER. IT IS RECOMMENDED THAT THE
COVERED BY APPLICATION OF WALL COVERING, FLOOR COVERING,
THE INTERIOR SEAMS AND CONNECTING PLATES TO BE CAULKED AND
8.
9.
10.
PANELS RUN.
DESIGN. SEAMS LINE UP ON SIDE WALLS AND CEILING IN DIRECTION
ALL CONNECTIONS ON ALL CLASSES OF VAULTS ARE WELDED LAP JOINT
SEE CUT SHEET FILE NUMBER 186-250.
HVAC PORT- SPECIFY LOCATION.
THE MAKE-UP PIECE MAY NOT BE NARROWER THAN 304mm (1'-0").
WILL BE USED TO ACHIEVE VAULT SIZES NOT IN MULTIPLES OF 1219mm (4'-0").
MAKE UP WALLS AND CEILING. A MAKE-UP PANEL (ONE OR TWO PER SIDE )
ALL CLASS II (5) SIDED VAULTS UTILIZE 1219mm (4'-0") WIDE PANELS TO
AND THE PANELS WELDED TO THE STEEL FLOOR. SEE DETAIL BELOW.
AS AN OPTION, THE VAULT WALL PANELS CAN BE INSTALLED ON STEEL FLOOR,
TO THE VAULT PANELS. SEE DETAIL BELOW.
TO THE FLOOR ALONG THE ENTIRE INSIDE PERIMETER OF VAULT, AND WELDED
" ANGLE IS ATTACHED 163FOR VAULTS WITHOUT FLOOR PANELS, A 2" X 2" X
MUST SPECIFY WALL OPENING SIZE.
OF VAULT DOOR OPENING.
SPECIFY LOCATION ON HINGE SIDE OR JAMB SIDE
DN VAULT DOOR IS STANDARD.
VAULT DOOR (STANDARD IN DN VAULT DOOR).
VAULT VENTILATOR IN PANEL MAY BE REQUIRED WITH OTHER
DETAIL "C"
EXCEED TOP OF SILL PLATE
FEATHERED TO EDGE OF VAULT DOOR SILL HEIGHT, BUT DOES NOT
FLOOR AS REQUIRED SO FINISHED FLOOR HEIGHT MEETS OR IS
APPLIED INSIDE AND OUTSIDE VAULT. OWNER'S G.C. TO PREPARE
OWNER'S G.C. TO VERIFY FLOOR COVERING THICKNESS TO BE
SE
E N
OT
E
BY O
WN
ER
S G.C.
FL
OO
R FINIS
H
SE
E N
OT
E
OW
NE
RS G.C.
FL
OO
R FINIS
H B
Y
VAULT DOOR SILL PLATE
(1'-8")
508
NOTE:
FIL
E N
O. 186-2
47 R
EV. 0
VAULTINSIDE
PANEL
VAULT WALL
VAULTOUTSIDE
VAULTOUTSIDE
VAULTINSIDE
INSTALLERS
ANCHOR BY DIEBOLD NIXDORF
") X 76mm (3") SLEEVE 2113mm (
BY DIEBOLD NIXDORF INSTALLERS
" ANGLE 8351mm (2") X 51mm (2") X
BY DIEBOLD NIXDORF INSTALLERS
305mm (12") ON CENTER
) WELD EVERY 32325mm (1") X 3mm (
VAULT PANEL WELDED TO ANGLE
BY DIEBOLD NIXDORF INSTALLERS
305mm (12") ON CENTER
) WELD EVERY 32325mm (1") X 3mm (
VAULT PANEL WELDED TO STEEL FLOOR
(7")
178
(7")
178
PANEL
VAULT WALL
STEEL FLOOR
25mm (1")
ANGLE IRON INSTALLATION
STANDARD VAULT WALL PANEL
STEEL PLATE FLOOR MOUNTING
VAULT WALL PANEL