click logo to begin. powered-air purifying respirator (papr) refresher training

22
Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Upload: brady-winkles

Post on 01-Apr-2015

227 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Click logo to begin.

POWERED-AIR PURIFYING RESPIRATOR

(PAPR)Refresher Training

Page 2: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Learning Objectives next

previous

Slide 2 of 22

At the end of the

training, you will be

able to:

Page 3: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

What is a PAPR?next

previous

Slide 3 of 22

A Powered-Air Purifying Respirator (PAPR) is a high efficiency powered air blower/filtration unit that consists of motor-driven fan and battery pack.

The fan draws contaminated air through the high efficiency filter before it enters the breathing tube in the rear of the headgear.

Page 4: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Capabilities of a PAPRnext

previous

Slide 4 of 22

Inertial Impaction - particles having too much inertia due to size or mass cannot follow the airstream as it is diverted around a filter fiber. This mechanism is responsible for collecting larger particles.

Interception - As particles pass close to a filter fiber, they may be intercepted by the fiber. Again, this mechanism is responsible for collecting larger particles.

Diffusion - Small particles are constantly bombarded by air molecules, which causes them to deviate from the airstream and come into contact with a filter fiber. This mechanism is responsible for collecting smaller particles.

Electrostatic Attraction - Oppositely charged particles are attracted to a charged fiber. This collection mechanism does not favor a certain particle size.

from NIOSH - Guidance for Protecting Building Environments from Airborne Chemical, Biological, or Radiological Attacks

Page 5: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Capabilities of a PAPRnext

previous

Slide 5 of 22from NIOSH - Guidance for Protecting Building Environments from Airborne

Chemical, Biological, or Radiological Attacks

Respiratory Protection against certain airborne particulate contaminants, including dusts, fumes, mists, and radionuclides.

Impaction and interception are the dominant collection mechanisms for particles greater than 0.2 µm, and diffusion is dominant for particles less than 0.2 µm.

Page 6: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Capabilities of a PAPRnext

previous

Slide 6 of 22

from OSHA – Assigned Protection Factors for the Revised Respiratory Protection Standard

The assigned protection factors (APF) for a loose-fitting face piece and a hood is 25. This means that the respirator offers protection against the contaminate at 25 times its Permissible Exposure Limit (PEL). The hooded PAPR can have an APF of 1000 if the respirator manufacturer can provide evidence that testing of the PAPR with the hood demonstrates performance at a level of protection of 1,000 or greater.

Page 7: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Limitations of a PAPRnext

previous

Slide 7 of 22

Do NOT use if:

– Atmospheres contain less than 19.5% oxygen

– Atmospheres presents an immediate dangerous to life or health condition

– Airflow of PAPR is less than 6 cfm

– Concentration of contaminants are unknown

– Toxic gases or vapors are present

– Any parts of PAPR are damaged

Page 8: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Why do you need a PAPR? next

previous

Slide 8 of 22

To Protect Yourself from Potential Exposure to Respiratory Pathogens and Particulates

• Tuberculosis (TB)• Select Agents

Avian Influenza Francisella tularensis Yersinia Pestis

• Aerosolization of Pathogens Flow Cytometry Sonication

• Animal Dander/Shedding

Picture from Belgian Biosafety Server

Pipetting generates aerosols.

Page 9: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

When do you need a PAPR?next

previous

Slide 9 of 22

• Entering any BSL3 or ABSL3 facilities

• Entering ABSL2 facilities if a N95 respirator is not sufficient

• Working in the Cell Sorting Facility with live BSL2 agents upon Biosafety Officer’s requirements

• Any tuberculosis research that involves or has the potential for aerosol formation

• Any task utilizing select agents

Page 10: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Who says you need a PAPR?next

previous

Slide 10 of 22

• The use of feasible engineering controls is the primary means to control air contaminants.

• Respirators are required when “effective engineering controls are not feasible, or while they are being instituted.”

• In some cases, where the hazard cannot be completely eliminated, and thus requires the use of a respirator.

Occupational Safety & Health Administration (OSHA) says…

Page 11: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

OSHA Respiratory Protection Standardnext

previous

Slide 11 of 22

29 CFR 1920.134

Requires:• Written Program and SOPs

– Describes procedures for routine use– Describes procedures for emergency situations

• Medical Evaluation• Annual Training• Annual Fit Testing

– Not required for PAPR Use

Page 12: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

How do you use a PAPR?next

previous

Slide 12 of 22

PAPR must always be inspected prior to donning and entering contaminated area.

Check hood for tears, rips, blistering, and discoloration of the material. For loose-fitting face pieces also check elasticity around the edges.

Check for creases and cracks in the face shield.

Check the hose for tears, pinholes, and blistering of material.

Check the green LED light on the battery. If the light is on when the battery is not plugged into the respirator, the battery is receiving power from the outlet. If the light is on when the battery is plugged into the respirator, the respirator should be fully charged (6 cfm for 8 hours).

Check the belt for damage.

Use the airflow indicator to ensure ample air and charge. Should be above top line.

Check motor unit for cracks and damage.

Page 13: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Putting on a PAPRnext

previous

Slide 13 of 22

Click the picture above to view the video

Page 14: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Taking off your PAPRnext

previous

Slide 14 of 22

Click the picture above to view the video

Page 15: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

What if my PAPR stops working?next

previous

Slide 15 of 22

1. Close all cultures, and leave everything in the biological safety cabinet.

2. Exit the lab as usual.

3. Notify your supervisor, facility manager, or respirator coordinator.

4. Get new personal protective equipment and respirator.

Page 16: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

How do I maintain my PAPR?next

previous

Slide 16 of 22

• Decontaminate the PAPR with a non-alcoholic, non-abrasive cleaner.

• Inspect the hood, hose, and PAPR unit for any damage.

• Hoods and hoses must be replaced 6 months after their initial use.

• Batteries are replaced every two years. • Filters and gaskets must be replaced

annually.– They must be changed inside a certified

biosafety cabinet inside containment, and under the watch of the respirator coordinator, facility manager or Biosafety Officer.

gasket

PAPR Unit Interior

Page 17: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

How do I maintain my PAPR?next

previous

Slide 17 of 22

The PAPR or PAPR parts should be replaced if the following conditions are present:

– If required by infection control procedures.

– If required by research protocols and/or procedures.

– If there is noticeable damage to the respirator.

– If the filter media of the respirator becomes wet or moist.

– If the respirator has become contaminated with blood or body fluids, and cannot adequately be decontaminated.

Page 18: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

How do I dispose of old PAPR parts?next

previous

Slide 18 of 22

• All old, replaced, nonoperational, or damaged PAPRs or PAPR parts must be decontaminated prior to disposal. – All PAPR parts (i.e. hoods, hoses, and filters) must be autoclaved

prior to disposal. – After decontamination, items must be disposed of as medical waste.

Page 19: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

How do I store my PAPR?next

previous

Slide 19 of 22

• Return the PAPR to the charging station– Batteries can be left on trickle charge for 30 consecutive days.

Longer periods of time may cause batteries to lose their capacity to hold a charge.

• Complete the respirator log book– when changing the filters and gaskets. Respirator use must be

recorded on sign in logs for daily use

• Store the hood and hose in a clean, dry area away from heat and direct sunlight– Ensure hood and hose are completely dry before storage

Page 20: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

User Responsibilitiesnext

previous

Slide 20 of 22

• Respirator should be inspected before and after each use.

• Inform your facility manager of any defects or improper PAPR function.

• The headpiece of the PAPR should be replaced every 6 months or when the hood begins to breakdown, which ever comes first.

• The respirator HEPA filter and gasket must be replaced every 12 months.

• PAPR batteries must be recharged after each use.

• After every use of the PAPR, the user must clean off the hood, breathing tube, and battery pack with disinfectant.

• Depending on your facility’s Respiratory Protection Plan, the facility manager or each user is responsible for maintaining a record for each PAPR which lists and documents maintenance and use history.

Page 21: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

Respiratory Protection Coordinators next

previous

Slide 21 of 22

Medical Science Building (MSB) - A900

International Center for Public Health (ICPH) &Regional Bio-containment Laboratories (RBL)

Users who do not have a respirator coordinator are responsible for the maintenance of their own respirators.

CONTACT LOCATION

Marilyn Ekonomidis BSL3 Manager

CONTACT LOCATION

Steve Park (A)BSL3 Manager and RBL 2nd Floor BSL3 Supervisor

Juanita Vakerich ABSL3 Supervisor

Blas Perez-Peixoto ICPH 2nd Floor BSL3 Supervisor

Bill Honnen ICPH 3rd Floor BSL3 Supervisor

Page 22: Click logo to begin. POWERED-AIR PURIFYING RESPIRATOR (PAPR) Refresher Training

EOHSS Contacts

previous

Slide 22 of 22

If you have any questions or need assistance, please contact us.

Tamara McNair, Biosafety Officer [email protected] (973) 972 - 8419

Jessica McCormick, Sr. Biosafety Officer [email protected] (973) 972 - 8424

Marta Figueroa, Director [email protected] (973) 972 - 5901

EOHSS Main Office (973) 972 - 4812

Click here to advance to the quiz