climate data records from operational microwave …• 183.31 +/- 1.00 ghz (channel 18) • uth:...
TRANSCRIPT
![Page 1: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/1.jpg)
© Crown copyright Met Office
Climate data records from operational microwave humidity soundersViju O. John
Thanks to R. P. Allan, S. A. Buehler, M. Milz, B. J. Soden
![Page 2: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/2.jpg)
© Crown copyright Met Office
Outline
This presentation covers the following topics:
• Motivation
• Operational humidity sounders
• Upper tropospheric Humidity
• Initial steps of homogenization
• Evaluation of radiosonde data
![Page 3: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/3.jpg)
© Crown copyright Met Office
Motivation• Water vapour in the upper troposphere (UT) is
an important climate variable (Held and Soden, 2000, Bates and Jackson, 2001)
• Good quality measurements are lacking (Foster and Collins, 2004)
- radiosonde data quality are not good in UT (lots, 19xx - 200x)
• IR (HIRS) measurements of UT water vapour available, but there is clear-sky bias in the data set (Lanzante and Gahrs, 2000)
• Microwave data (SSM/T2, AMSU-B, MHS) can be used except in the presence of precipitating clouds (Greenwald and Christopher, 2002)
μμ
![Page 4: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/4.jpg)
© Crown copyright Met Office
Channel characteristics
5 channel radiometers
AMSU-B and MHS - starting from 1999
SSM-T/2 from 1994
![Page 5: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/5.jpg)
© Crown copyright Met Office
• 183.31 +/- 1.00 GHz (Channel 18)
• UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa)
• A simple relation between radiance (brightness temperature) and UTH exists for IR 6.7µ TB (Soden and Bretherton, 1993, 96) and AMSU TB
18 (Buehler and John, 2005)
UTH Channel
![Page 6: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/6.jpg)
© Crown copyright Met Office
UTH from TB18
• ln(UTH) = a + b TB18
• Similar coefficients from independent data sets
• Retrieval precision is 2 %RH for low humidity and 7 %RH for high humidity
• Coefficients are calculated for all viewing angles
A similar relation is possible for MTH and TB19
![Page 7: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/7.jpg)
© Crown copyright Met Office
UTH is limb corrected
Regression coefficients are calculated for each viewing angle
Limb correction of radiances not needed
![Page 8: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/8.jpg)
© Crown copyright Met Office
UTH Spatial Distribution
![Page 9: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/9.jpg)
© Crown copyright Met Office
Cloud Filter
• Clear sky: TB20 > TB
18
• Cloudy: TB18 > TB
20
• TB18 > Threshold
![Page 10: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/10.jpg)
© Crown copyright Met Office
Cloud Filter
![Page 11: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/11.jpg)
© Crown copyright Met Office
% cloud contamination in IR and MW data
IR
Microwave
Cloudiness is correlated with RH
![Page 12: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/12.jpg)
© Crown copyright Met Office
Clear-sky sampling issues• Lanzante and Gahrs (2000) used radiosonde UTH data to
estimate the impact
• They found 5-10% dry bias in IR data set
• Due to poor data quality in the UT and insufficient spatial coverage radiosondes may not be the best data to use for this
• HIRS and AMSU-B/MHS are flying on same satellites with similar viewing geometries - this gives a unique opportunity to estimate the clear-sky sampling bias
• 2008 data from MHS and HIRS on MetOp are used; MHS pixels are mapped to HIRS grid and then sub-sampled for clear HIRS pixels
![Page 13: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/13.jpg)
© Crown copyright Met Office
MW and IR sampling - Daily mean
Grid resolution = 1 x 1 degree
![Page 14: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/14.jpg)
© Crown copyright Met Office
Daily mean time series
Area weighted tropical average time series
![Page 15: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/15.jpg)
© Crown copyright Met Office
MW and IR sampling - # of pixels
Monthly, 1 x 1 degree grids
![Page 16: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/16.jpg)
© Crown copyright Met Office
MW and IR sampling – monthly mean
![Page 17: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/17.jpg)
© Crown copyright Met Office
MW and IR sampling – clear-sky bias
There are larger values - up to -35 %
![Page 18: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/18.jpg)
© Crown copyright Met Office
MW and IR sampling - variability
![Page 19: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/19.jpg)
© Crown copyright Met Office
MW and IR sampling - Trend?
ERA-Interim 500 hPa RH and cloud cover
Clear = cloud cover < 30%
![Page 20: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/20.jpg)
© Crown copyright Met Office
Diurnal Cycle
Chung et al., 2007
N15
N16
AD
A
D
Land Ocean
![Page 21: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/21.jpg)
© Crown copyright Met Office
Diurnal Cycle
Difference between ascending and descending passes
Strongly associated with convection
![Page 22: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/22.jpg)
© Crown copyright Met Office
Orbital drift?
Drift in NOAA-15 may be due to orbital drift.
![Page 23: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/23.jpg)
© Crown copyright Met Office
SNO Example
![Page 24: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/24.jpg)
© Crown copyright Met Office
Drift in brightness temperature
![Page 25: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/25.jpg)
© Crown copyright Met Office
Inter Satellite Differences
Using simultaneous nadir overpasses
Large inter-satellite biases
Bias is not constant over time
![Page 26: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/26.jpg)
© Crown copyright Met Office
![Page 27: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/27.jpg)
© Crown copyright Met Office
Radiosonde quality issuesVaisalaLindenberg, Germany
Goldbeater’s skin Kem, Russia
Slight dry bias Large wet bias
Slight dry biasLarge radiation dry bias
Results using ARMData (TWP-C1)
Moradi et al., 2010Submitted to JGR
![Page 28: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/28.jpg)
© Crown copyright Met Office
Day/night biases
European stations; data from 2001 to 2003
![Page 29: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/29.jpg)
© Crown copyright Met Office
Summary and future plans
• Gridded daily and monthly UTH data set available from operational microwave sounders
• As cloud impact is insignificant, MW UTH data can be used to estimate CSB in IR UTH
• Significant diurnal cycle in UTH
• Working on inter-satellite calibration, orbital drift correction, MTH retrieval, SSM-T/2, ...
![Page 30: Climate data records from operational microwave …• 183.31 +/- 1.00 GHz (Channel 18) • UTH: Jacobian weighted relative humidity in the “upper troposphere” (500-200 hPa) •](https://reader033.vdocument.in/reader033/viewer/2022060408/5f0fee777e708231d4469a08/html5/thumbnails/30.jpg)
© Crown copyright Met Office
Questions??