cliq power supply integration. general view: -schroff rack 19’’ 25u (500mm x 600mm x 1120mm). -2...

11
CLIQ power supply Integration

Upload: allen-paul

Post on 23-Dec-2015

218 views

Category:

Documents


1 download

TRANSCRIPT

CLIQ power supply

Integration

General view:-Schroff rack 19’’ 25U (500mm x 600mm x 1120mm).-2 fixed wheels +2 castor wheels with brake 100mm.⦰

Capacitors bank: 2 Capacitors fixed on a aluminium plate

Rack 19’’fixed on a aluminium plate

L shape Aluminium profile to fix capacitors

Internal Discharge board:

Resistors bank 1.36KΩ 340W

2 “Discharge” relays

Bus bars tinned which put the capacitors in parallelOutput voltage connected to thyristors

Output voltage

Burndy female 7 polesConnected to the control crate

Rear panel:

Burndy 4 male connectorTigger input

Socapex female connector or terminals WeidmullerOutput voltage

Filter schaffner 6A

Mains circuit breaker

Thyristors assembly mounted on a fibber glass isolator

Burndy 7 poles male Mains input

PCB with pulse transformer

Crate control:

SDS Power supply withGreen led “End of charge”Red led “Ucap>40VdcLCD Current indicatorLCD Voltage indicatorSelector 0-500V

Push button Start charging

Emergency stop

Light Mains indicator

Burndy 7 poles female Power supply outputand discharge relays command

Burndy 7 poles maleMains input

Burndy 4 femaleOutput thyristor commandBurndy 4 male

Trigger input

Safety aspect:-The power supply is fully closed with special safety screws.-All panels are connected to the earth.-Stickers with warnings are placed on front and back.

-2 protection covers with HV warning stickers.