co «, SITE PLAN pEG pOl.10 czo C.) '7,5b ‹<- pEG pl_ACE.A) T TOTAL -8,#ffLTR 60 Designology 212 Amelia Lane, Newbury VICTORIA - AUSTRALIA DESIGN & BUILDING CONSULTANTS. MOBILE - 0416 056 651 EMAIL - kevingdesignology.com.au w - www.designology.com.au , •64.7 •64.71 ,91O (10 o /1/ tOk• /1/ Q / 0 57.4a- - - / 61. 57 80 / ,:"., , (5 ' / ,31.. , 0 , / , , / / , , / / , , 1 , , / , / , CFA FIRE FIGHTING / / / 10,000IUR WATER TANK! 0' / refer foiMS ( June202 i e, , Re7,3374,, , /// / / 1,1 / / / 4:7/ / / NTGACTOR SH L RIFY ALL LEVELS, D SIZES PRIOR TO I MENCEMENT OF AN DRAWINGS. ALL WORKS' ' 'RIED OUT ARE TO C CODE OF A RALIA, STANDARDS RELEVANT AUTHORITIES, R REQUIREMENTS AND BY-LA ENSIONS AND WORK OR SHOP PLY WITH THE BUILDING USTRALIA, LOCAL AND ALL ULATIONS, STATUTORY , WHICH HAVE JURISDICTION OVER THE BUILDING WORKS. tets .00 • NEW LEVEL o EXISTING GROUND LEVEL ISSUE REVISIONS EXISTING TREE REMOVED EXISTING TREE RETAINED DATE DRAWN sp DATE - REF FIRE FIGHTING NOTES Standard bushfire requirements to also be satisfied are as o 10,000Itr. above ground water tank conc. or metal - A minimum of 10,000 litres effective water supply for fire fighting purposes must be established and maintained on the site that is stored in an above ground water tank constructed of concrete or metal. All fixed above-ground water pipes and fittings required for fire fighting purposes must be made of corrosive resistant metal. o The water supply must meet the following requirements: - The outlet/s of the water tank must be within 4m of the accessway and be unobstructed. o Accessway needs 3.5m trafficable width + 0.5m each side for firefighter access. o The water supply system must be designed such that it will be hydraulically possible for a CFA appliance to draw water from the outlet, when taking into account site conditions. o Be readily identifiable from the building or appropriate identification signage to the satisfaction of CFA must be provided. o Include a riser up to the road level with a coupling (64mm CFA 3 thread per inch male fitting). o Incorporate a ball or gate valve (British Standard Pipe (BSP) 65mm) o All pipework and fittings must be a minimum of 65mm (excluding the CFA coupling). o If the elevation from the base of the water supply to the outlet point is greater than 6m a pump will need t o be installed at the supply to boost the water up to the outlet point. Installation would be to AS 2419.1 2005 - Fire Hydrant Installations standard e.g. use of 100 ml pipe etc. o If a pump is installed it is preferable that the pump is diesel operated. The pump should be installed in a ventilated non-combustible enclosure to protect it from radiant heat. Weatherproof signage indicating the placement of the pump and the pumps operating instructions shall be placed both at the pump and at the outlet point. CFA FIRE FIGHTING 10,000LTR WATER TANK refer to BMS ( june2021) Ref =3374/1 RAINWATER TANKS TOTAL = 8,000LTR MARCH 2021 CHECKED PROPOSED NEW DWELLING FOR AT EDWARD HUTCHINSON No.6. ILUKA AVE. WYE RIVER DRAWING SITE PLAN PDF FILE SAVE - 20 SEPT 2021 VER -2 SCALE 1 / 200 JOB No. SHEET 02 0F14 D21/199862

Upload: others

Post on 11-Jan-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

co «,

SITE PLAN

pEG pOl.10

czo

C.)

'7,5b

‹<-

pEG pl_ACE.A)

T TOTAL -8,#ffLTR

60

Designology 212 Amelia Lane, Newbury

VICTORIA - AUSTRALIA DESIGN & BUILDING CONSULTANTS.

MOBILE - 0416 056 651 EMAIL -

kevingdesignology.com.au

w - www.designology.com.au

, •64.7 •64.71

,91O (10

o /1/ tOk• /1/ Q / 0

57.4a- - -

/ 61.

57 80

/ ,:"., , (5' / ,31.. , 0 , /

, , „ / „ / , , / / , , 1 , , / , / , CFA FIRE FIGHTING / / / 10,000IUR WATER TANK! 0'

/ refer foiMS ( June202 i

„ e, , Re7,3374,, , „ „ ///

/ /

1,1 / /

/ 4:7/

/ /

NTGACTOR SH L RIFY ALL LEVELS, D SIZES PRIOR TO I MENCEMENT OF AN

DRAWINGS.

ALL WORKS' ' 'RIED OUT ARE TO C CODE OF A RALIA, STANDARDS

RELEVANT AUTHORITIES, R REQUIREMENTS AND BY-LA

ENSIONS AND WORK OR SHOP

PLY WITH THE BUILDING USTRALIA, LOCAL AND ALL

ULATIONS, STATUTORY

, WHICH HAVE JURISDICTION

OVER THE BUILDING WORKS.

tets .00

• NEW LEVEL

o EXISTING GROUND LEVEL

ISSUE REVISIONS

EXISTING TREE REMOVED

EXISTING TREE RETAINED

DATE DRAWN sp

DATE -

REF

F I R E F I G H T I N G NOTES

Standard bushfire requirements to also be satisfied are as

o 10,000Itr. above ground water tank conc. or metal - A minimum o f 10,000 litres effective water supply f o r fire fighting purposes must be established and maintained on the site that is stored in an above ground water tank constructed o f concrete or metal. All fixed above-ground water pipes and fittings required f o r fire fighting purposes must be made of corrosive resistant metal.

o The water supply must meet the following requirements:

- The outlet/s of the water tank must be within 4m of the accessway and be unobstructed.

o Accessway needs 3.5m trafficable width + 0.5m each side for firefighter access.

o The water supply system must be designed such that it will be hydraulically possible for a CFA appliance to draw water from the outlet, when taking into account site conditions.

o Be readily identifiable from the building or appropriate identification signage t o the satisfaction of CFA must be provided.

o Include a riser up to the road level with a coupling (64mm CFA 3 thread per inch male fitting).

o Incorporate a ball or gate valve (British Standard Pipe (BSP) 65mm)

o All pipework and fittings must be a minimum of 65mm (excluding the CFA coupling).

o If the elevation from the base of the water supply to the outlet point is greater than 6m a pump will need to be installed at the supply to boost the water up to the outlet point. Installation would be to AS 2419.1 2005 - Fire Hydrant Installations standard e.g. use of 100 ml pipe etc.

o If a pump is installed i t is preferable that the pump is diesel operated. The pump should be installed in a ventilated non-combustible enclosure to protect it from radiant heat. Weatherproof signage indicating the placement o f the pump and the pumps operating instructions shall be placed both at the pump and at the outlet point.

CFA FIRE FIGHTING 10,000LTR WATER TANK refer to BMS ( june2021) Ref =3374/1

RAINWATER TANKS TOTAL = 8,000LTR

MARCH 2021

CHECKED

PROPOSED NEW DWELLING

FOR

AT

EDWARD HUTCHINSON

No.6. ILUKA AVE. WYE RIVER

DRAWING SITE PLAN

PDF FILE SAVE - 20 SEPT 2021

VER -2

SCALE 1 / 200

JOB No.

SHEET 0 2 0F14

D21/199862

Des1gnology p/I 212 Amelia Lane, Newbury VICTORIA - AUSTRALIA

DESIGN & BUILDING CONSULTANTS.

MOBILE - 0416 056 651 EMAIL -

kevingdesignology.com.au

W - www.designology.com.au

CFA FIRE FIGHTING 10,000LTR WATER TA

S ( june2 4/1

0 EXISTING GROUND LEVEL

PDF FILE SAVE -20 SEPT 2021

CONTRACTOR SHALL VERIFY ALL LEVELS, DIMENSIONS AND SIZES PRIOR TO COMMENCEMENT OF ANY WORK OR SHOP

DRAWINGS.

ALL WORKS CARRIED OUT ARE TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, STANDARDS AUSTRALIA, LOCAL AND ALL

RELEVANT AUTHORITIES, REGULATIONS, STATUTORY REQUIREMENTS AND BY-LAWS, WHICH HAVE JURISDICTION

OVER THE BUILDING WORKS.

ISSUE REVISIONS DATE DRAWN VER -2 sp PROPOSED NEW DWELLING

DATE - APRIL 2021 FOR EDWARD HUTCHINSON

SCALE 1 /200

REF AT No.6. ILUKA AVE. WYE RIVER

JOB No.

CHECKED DRAWING SATELLITE VIEW - PLAN SHEET 0 3 OF 14