co reducing cooler2012).pdfrkf provide superior performance more when the outside temperature is...

2
120005A Green Energy-saving Natural Evaporative Air Cooler 4-1 Yamana-cho,Fukuroi-shi,Shizuoka-ken 437-8601 Japan Phone : +81-538-23-3990 Fax : +81-538-23-3192 E-mail : [email protected] URL : http://www.shizuoka-seiki.co.jp/eg.html Specifications Model RKF505 RKF405 Caution After every operation, stop the cooler by Auto-stop operation in order to dry the cooling element. The drying operation lasts for about 20 - 40 minutes. Thereafter, operation stops automatically. Operating this cooler in closed area may result in the increase of humidity. This may then cause not only decreased cooling effect but rust with other equipments or materials. 1 The above specifications are derived when the temperature of air at inlet is 30(86F) and its relative humidity is 50%. ■Cool air distribution Difference of air temp. 2.5 5.9 6.1 6.7 8.3 10.1 14.1 15.7mph 1.1 12m 10m 7m 6m 5m 4m 3m 2m 1m 36ft 30ft 21ft 18ft 15ft 12ft 9ft 6ft 3ft 2.6 2.7 3.0 3.7 4.5 6.3 7m/s -6℃ -4℃ -3℃ -2℃ -1℃ -10.8F -7.2F -5.4F -3.6F -1.8F Wind speed Swing range 80° from right to left RKF 505 10.1mph 4.5m/s 5.9 8m 7m 6m 5m 4m 3m 2m 1m 24ft 21ft 18ft 15ft 12ft 9ft 6ft 3ft 2.5 2.7 3.4 4.5 5.6 1.1 1.2 1.5 2.0 2.5 -6℃ -10.8F -4℃ -7.2F -3℃ -5.4F -2℃ -3.6F -1℃ -1.8F ■Cool air distribution Difference of air temp. Wind speed Swing range 80° from right to left RKF 405 Power source Power consumption Cooling capacity*1 Air flow (MAX) Amt. of water evaporation*1 Tank capacity Cont. operating time*1 Safety devices Operation noise Dimensions (H×W×D) Dry weight 120V 60Hz 520W 8.5kW 150 m 3 /min 5,300 CFM 12.2 liters 3.2 gallons 230V 50Hz 360W 7.5kW 130 m 3 /min 4,600 CFM 10.2 liters 2.7 gallons 50 liters 13.2 gallons Fuse, Water shortage detection, Motor overheat protection 4.0 hours 4.8 hours 1,565×680×655 mm 61.6×26.8×25.8 inch 78 kg 172.0 lbs 1,368×562×563 mm 53.9×22.2×22.2 inch 47 kg 103.7 lbs 8.9 hours 10.0 hours 68 dB(A) 65 dB(A) 63 dB(A) 59 dB(A) 120V 60Hz 290W 4.4kW 115 m 3 /min 4,100 CFM 5.6 liters 1.5 gallons 230V 50Hz 230W 3.9kW 105 m 3 /min 3,700 CFM 5.0 liters 1.4 gallons An Earth Friendly Product CO2 Reducing Cooler

Upload: others

Post on 31-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CO Reducing Cooler2012).pdfRKF provide superior performance more when the outside temperature is high Drying mode for cooling element 22 /71.6F 30 /86F Humidity: 40% Humidity: 60%

120005A

Green Energy-saving Natural

Evaporative Air Cooler

4-1 Yamana-cho,Fukuroi-shi,Shizuoka-ken 437-8601 JapanPhone : +81-538-23-3990 Fax : +81-538-23-3192E-mail : [email protected] : http://www.shizuoka-seiki.co.jp/eg.html

Specifications

Model RKF505 RKF405

Caution・After every operation, stop the cooler by Auto-stop operation in order to dry the cooling element. The drying operation lasts for about 20 - 40 minutes. Thereafter, operation stops automatically. ・Operating this cooler in closed area may result in the increase of humidity. This may then cause not only decreased cooling effect but rust with other equipments or materials.

*1 The above specifications are derived when the temperature of air at inlet is 30℃(86F) and its relative humidity is 50%.

■Cool air distribution

Difference of air temp.

2.5 5.9 6.1 6.7 8.3 10.1 14.1 15.7mph1.1

12m 10m 7m 6m 5m 4m 3m 2m 1m36ft 30ft 21ft 18ft 15ft 12ft 9ft 6ft 3ft

2.6 2.7 3.0 3.7 4.5 6.3 7m/s-6℃-4℃-3℃-2℃-1℃-10.8F-7.2F-5.4F-3.6F-1.8F

Wind speed

Swing range 80°from right to left

RKF505

10.1mph4.5m/s

5.9

8m 7m 6m 5m 4m 3m 2m 1m24ft 21ft 18ft 15ft 12ft 9ft 6ft 3ft

2.5 2.7 3.4 4.5 5.61.1 1.2 1.5 2.0 2.5

-6℃-10.8F

-4℃-7.2F

-3℃-5.4F

-2℃-3.6F

-1℃-1.8F

■Cool air distribution

Difference of air temp.

Wind speed

Swing range 80°from right to left

RKF405

Power source

Power consumption

Cooling capacity*1

Air flow (MAX)

Amt. of water evaporation*1

Tank capacity

Cont. operating time*1

Safety devices

Operation noise

Dimensions (H×W×D)

Dry weight

120V 60Hz

520W

8.5kW

150 m3/min 5,300 CFM

12.2 liters 3.2 gallons

230V 50Hz

360W

7.5kW

130 m3/min 4,600 CFM

10.2 liters 2.7 gallons

50 liters 13.2 gallons

Fuse, Water shortage detection, Motor overheat protection

4.0 hours 4.8 hours

1,565×680×655 mm 61.6×26.8×25.8 inch

78 kg 172.0 lbs

1,368×562×563 mm 53.9×22.2×22.2 inch

47 kg 103.7 lbs

8.9 hours 10.0 hours

68 dB(A) 65 dB(A) 63 dB(A) 59 dB(A)

120V 60Hz

290W

4.4kW

115 m3/min 4,100 CFM

5.6 liters 1.5 gallons

230V 50Hz

230W

3.9kW

105 m3/min 3,700 CFM

5.0 liters 1.4 gallons

An Earth Friendly Product

CO2 Reducing Cooler

Page 2: CO Reducing Cooler2012).pdfRKF provide superior performance more when the outside temperature is high Drying mode for cooling element 22 /71.6F 30 /86F Humidity: 40% Humidity: 60%

RKF Series has adopted the natural cooling phenomenon from a waterfall and applied it to its cooler which creates a comfortable working environment. Cooling air by vaporizing water, this vaporization cooling system emits no heat exhaust, is earth friendly and health-oriented.

Cool air by water evaporation

NEW

Supply cool air widely and farther away

Economic efficiency

Easy cleaning for water tankEasy transport

Adjustable speeds

Easy operation and maintenance

❶ Water in the tank is pumped up to water spray bar and then sprayed on cooling element.❷ Evaporation occurs in the cooling element which causes actual temperature of the air   to decrease.❸ Large fan distributes the cooled air farther away.

■ Mechanism

Mobile airconditioner

RKF405

RKF405 RKF505 Mobile air conditionersingle two three

3,000

2,000

1,000

2.2kW

89% saving0.245kW(60Hz)

■Comparison of power consumption

■Power consumption(W)

Water can easily be poured into the tank by a bucket.

New useful function for RKF505

Cool air can reach whole bodyby vertical auto-louver

Cool air can cover a wide rangeby horizontal auto-louver

This wire mesh prevents accidental insertion of fingers or objects.

Equipped with casters for easy moving

Water tank is easily taken out by releasing joint connectors. Water tank is easy to clean due to its large hole.

After every operation, cooling element is dried using the Auto-stop operation. This helps to keep the cooler clean

Easy touch button selector for high, medium or low air volumes

RKF503

5

4

3

2

1

0RKF505

wind speed3.1m/s

wind speed4.5m/s

Wind speed is 45% up at four meters (12 feet) ahead

Wind speed is 45% up at four meters (12 feet) ahead

Increased feeling of coolness byincreased wind speed

Horizontal and vertical auto-louvers Enhanced safety

Water tank is easily filled with water via a hose. Auto water supply can be chosen as well.

Easy water supply

Sensible body temperature is decreased by the increase in wind speed.

RKF never emits exhaust heat unlike an air conditioner because RKF is not equipped with a compressor.

Global greenhouse gas (GHG) emission per month

■ RKF505

■ RKF40549.2kg

24.1kg

………

………

RKF405Air conditioner

50

100

150

200

24.1kg

216.0kg

191.9kg191.9kg

Energy savingEnergy saving

Contributes to thereduction of CO2Contributes to thereduction of CO2

No heat fromexhaustNo heat fromexhaust

■ RKF505………

■ RKF405………

360W(230V, 50Hz)520W(120V, 60Hz)230W (230V, 50Hz)290W (120V, 60Hz)

Power consumption

■ Comparison of power  consumption between  RKF405 & typical air  conditioner

RKF405

720W

230W/290W

68% / 60% saving

Air conditioner

■ Comparison of GHG  emission per month between RKF405  and air conditioner

Evaporative Air Cooler

Coolair

RKF provide superior performance morewhen the outside temperature is high

Drying mode for coolingelement

22℃/71.6F 30℃/86FHumidity:40%

Humidity:60%

Waterflow

35℃/95F30℃/86F35℃/95F

26℃/78.8F25℃/77F29.5℃/85.1F

Cooling elementFanAir outlet

Reservoir tank

Filter

Pump

Water spray bar

Green Energy-saving Natural