coaxial cables

Upload: james-e-hutapea

Post on 31-Oct-2015

52 views

Category:

Documents


0 download

TRANSCRIPT

- Coaxial Cables

- Connectors RG-8, RG-6, RG-58, BNC - LSA, K-52, K-57 Block - DDF LSA Mount frame

- Antenna Mounting- 19" Rack- PCM Cables

- Grounding Cables- Grounding Bar

- Grounding Kits

- Cable Clamp 1/4", 7/8", 15/8"

- Cable Ties

- OthersKrone - 50 Pair Termination/Punch BlockCode:6652-1-880-10Price: $41.38Quantity in Basket:none

Krone - 25 Termination/Punch BlockCode:6639-1-003-01Price: $23.06Quantity in Basket:none

Krone - R89D Mounting BracketCode:6639-3-016-00Price: $2.50Quantity in Basket:none

Krone - 50 Pair Termination/Punch Block With Female RJ-21'sCode:6639-1-051-02-01Price: $111.75Quantity in Basket:none

Krone - 50 Pair Termination/Punch Block With RJ-45'sCode:6639-1-052-01Price: $187.50Quantity in Basket:none

Krone - 50 Pair Termination/Punch Block With RJ-48'sCode:6639-1-050-33Price: $171.00Quantity in Basket:none

Krone - LSA-PLUS Insertion/Punch ToolCode:6417-2-055-01Price: $82.75Quantity in Basket:none

Krone - Disposable Insertion/Punch ToolCode:6417-3-006-01Price: $2.95Quantity in Basket:none

Krone - Hinged Dust CoverCode:6639-2-004-00Price: $13.98Quantity in Basket:none

Krone - Center Labeling StripCode:6639-3-019-00Price: $7.43Quantity in Basket:none

Krone - Clear Dust CoverCode:6586-3-004-00Price: $10.95Quantity in Basket:none

Krone - Winged Test Adapter, Used for MonitoringCode:6646-2-928-00Price: $18.27Quantity in Basket:none

Krone - Rack Mount - 4 BlocksCode:6652-2-004-49Price: $78.75Quantity in Basket:none

Krone - 12 Port Mini Patch Panel - BlankCode:6653-2-705-12Price: $24.75Quantity in Basket:none

Krone - Single Pair Isolating Patch Cord, 4 ft.Code:6647-2-000-04Price: $22.65Quantity in Basket:none

Krone - Single Pair Isolating Patch Cord, 7 ft.Code:6647-2-000-07Price: $25.80Quantity in Basket:none

Krone - Single Pair Isolating Patch Cord, 10 ft.Code:6647-2-000-10Price: $28.13Quantity in Basket:none

Krone - Single Pair Isolating Patch Cord, 15 ft.Code:6647-2-000-15Price: $28.50Quantity in Basket:none

Krone - 2-Pair Isolating Patch Cord, 4 ft.Code:6647-2-753-04Price: $52.80Quantity in Basket:none

Krone - 2-Pair Isolating Patch Cord, 7 ft.Code:6647-2-753-07Price: $53.70Quantity in Basket:none

Krone - 2-Pair Isolating Patch Cord, 10 ft.Code:6647-2-753-10Price: $51.00Quantity in Basket:none

Krone - 2-Pair Isolating Patch Cord, 15 ft.Code:6647-2-753-15Price: $54.45Quantity in Basket:none

Krone - 1-Pair Bridging Patch Cord, 1 ft.Code:6646-2-900-01Price: $26.55Quantity in Basket:none

Krone - 1-Pair Bridging Patch Cord, 4 ft.Code:6646-2-900-04Price: $29.03Quantity in Basket:none

Krone - 1-Pair Bridging Patch Cord, 7 ft.Code:6646-2-900-07Price: $29.85Quantity in Basket:none

Krone - 1-Pair Bridging Patch Cord, 10 ft.Code:6646-2-900-10Price: $31.50Quantity in Basket:none

Krone - 4-Pair Isolating Patch Cord, 4 ft.Code:6647-2-752-04Price: $52.05Quantity in Basket:none

Krone - 4-Pair Isolating Patch Cord, 7 ft.Code:6647-2-752-07Price: $67.95Quantity in Basket:none

Krone - 4-Pair Isolating Patch Cord, 10 ft.Code:6647-2-752-10Price: $59.50Quantity in Basket:none

Krone - 4-Pair Isolating Patch Cord, 15 ft.Code:6647-2-752-15Price: $73.50Quantity in Basket:none

Krone - 1-Pair Look Both Ways Patch Cord, 1 ft.Code:6647-2-900-01Price: $48.15Quantity in Basket:none

Krone - 1-Pair Look Both Ways Patch Cord, 4 ft.Code:6647-2-900-04Price: $48.38Quantity in Basket:none

Krone - 1-Pair Look Both Ways Patch Cord, 7 ft.Code:6647-2-900-07Price: $50.03Quantity in Basket:none

Krone - 1-Pair Look Both Ways Patch Cord, 10 ft.Code:6647-2-900-10Price: $50.55Quantity in Basket:none

Krone - Single Pair Monitoring to RJ-45 Patch Cord, 7 ft.Code:6646-2-300-07Price: $19.13Quantity in Basket:none

Krone - Single Pair Monitoring to RJ-45 Patch Cord, 10 ft.Code:6646-2-300-10Price: $20.18Quantity in Basket:none

Krone - Single Pair Monitoring to RJ-45 Patch Cord, 15 ft.Code:6646-2-300-15Price: $18.50Quantity in Basket:none

Krone - 2-Pair to RJ-45 Isolating Patch Cord, 568A, 4 ft.Code:6647-2-762-04Price: $36.30Quantity in Basket:none

Krone - 2-Pair to RJ-45 Isolating Patch Cord, 568A, 7 ft.Code:6647-2-762-07Price: $37.80Quantity in Basket:none

Krone - 2-Pair to RJ-45 Isolating Patch Cord, 568A, 10 ft.Code:6647-2-762-10Price: $38.63Quantity in Basket:none

Krone - 2-Pair to RJ-45 Isolating Patch Cord, 568A, 15 ft.Code:6647-2-762-15Price: $41.33Quantity in Basket:none

Krone - 2-Pair to RJ-45 Isolating Patch Cord, 568B, 4 ft.Code:6647-2-782-04Price: $35.78Quantity in Basket:none

Krone - 2-Pair to RJ-45 Isolating Patch Cord, 568B, 7 ft.Code:6647-2-782-07Price: $37.20Quantity in Basket:none

Krone - 2-Pair to RJ-45 Isolating Patch Cord, 568B, 10 ft.Code:6647-2-782-10Price: $38.55Quantity in Basket:none

Krone - 2-Pair to RJ-45 Isolating Patch Cord, 568B, 15 ft.Code:6647-2-782-15Price: $40.77Quantity in Basket:none

Krone - 4-Pair to RJ-45 Isolating Patch Cord, 568B-L, 4 ft.Code:6647-2-751-04Price: $40.05Quantity in Basket:none

Krone - 4-Pair to RJ-45 Isolating Patch Cord, 568B-L, 7 ft.Code:6647-2-751-07Price: $41.63Quantity in Basket:none

Krone - 4-Pair to RJ-45 Isolating Patch Cord, 568B-L, 10 ft.Code:6647-2-751-10Price: $43.50Quantity in Basket:none

Krone - 4-Pair to RJ-45 Isolating Patch Cord, 568B-R, 4 ft.Code:6647-2-774-04Price: $43.95Quantity in Basket:none

Krone - 4-Pair to RJ-45 Isolating Patch Cord, 568B-R, 7 ft.Code:6647-2-774-07Price: $53.93Quantity in Basket:none

Krone - 4-Pair to RJ-45 Isolating Patch Cord, 568B-R, 10 ft.Code:6647-2-774-10Price: $55.80Quantity in Basket:none

E1 atau sirkuit E-1 (Inggris: E-carrier) adalah nama format transmisi digital dengan 30 kanal suara digital berkecepatan 2,048 megabit per detik. E1 merupakan standar yang dipakai di Eropa dan Indonesia. Standar E1 ini ekivalen dengan standar T1 yang dipakai di Amerika, dengan perbedaan T1 menggunakan 24 kanal suara digital dengan kecepatan 1,554 megabit per detik.Saluran ini berbentuk saluran telepon khusus dan digunakan pada awalnya untuk sambungan trunk antar sentral telepon, namun sekarang mulai banyak disewakan oleh perusahaan telekomunikasi untuk jalur komunikasi data.Dibawah ini merupakan gambar kabel UTP E1 alias RJ48, dan sebagai pembandingnya saya sertakan kabel UTP RJ45 alias Fast Ethernet :Kiri RJ45 & Kanan E1RJ45 & E1

Dari gambar diatas dapat kita lihat perbedaannya yang sangat mencolok, yaitu dari sisi:1. Jumlah Kabel2. Warna KabelDisebelah kiri adalah kabel UTP RJ45 yang memiliki jumlah 8 kabel dan 2 tipe warna(belang & polos), sedangkan disebelah kanan adalah kabel E1 yang berjumlah 4 kabel dan dilapisi kertas alumunium yang kemudian baru dibungkus serat kawat tipis yang melingkari isi keseluruhan kabel.Sedangkan DDF adalah :DDF adalah perangkat distribusi, antara multiplekser digital dan perangkat tukar menukar yang digunakan antara multiplexersequipment digital atau peralatan non layanan suara, melaksanakan fungsi-fungsi seperti koneksi kabel, kabel patch dan uji loop yang mentransmisikan sinyal digital.DDF LSA+ K52DDF LSA+ K52

DDF berfungsi sebagai alat untuk me-loop kan koneksi antara TX dan RX dari kabel E1 dalam bertukar data. Dalam protokol persinyalan, akan ada TX (input) dan RX (output), kedua hal tersebut harus terhubung dalam 1 garis karena RX (output) dari provider akan menuju kepada TX (input) customer yang menggunakan fasilitas ini. Untuk meng-cross kan sinyal TX (input) dan RX (output), maka digunakanlah DDF.Mengapa DDF berikut saya berikan judul DDF LSA+ ?, karena memang jenis DDF ini adalah LSA+ seperti yang anda lihat gambar samar-samar disebelah sisi kanan. Sedangkan jenis DDF itu sendiri ada 2 yaitu :1. K522. K57Untuk yang jenis K52 sudah saya tampilkan seperti gambar diatas, sedangkan K57 saya tidak punya alatnya:DGambar dibawah ini adalah alat untuk meng-cross connect kabel E1 pada DDF.Krone K52DDF Krone

Mengapa saya membahas DDF dan E1 tersebut secara bersamaan?, jawabannya dapat anda lihat dibawah ini :

CrossconnectYa betul, kabel UTP E1/RJ48 digunakan sebagai jalur data, sedangkan DDF adalah alat untuk mempertemukan antara TX (input) dan RX (output) dengan cara mempertemukan sisi kabel E1 yang berbeda.Caranya adalah :Client MachineRouter

1.2.3.4.PutihCoklatHijauKuningHijauKuningPutihCoklat

* 1-4 : Nomor urutan kabel pada jack UTP.* Baik client maupun router, dapat menggunakan warna milik lawan asal tetap seperti diatas.Warna yang ada pada kabel UTP E1 alias RJ48, dikoneksikan seperti tabel diatas agar dapat terhubung dengan baik.

Tipe Cross

Pada tipe ini ujung kabel yang satu menggunakan urutan standart EIA/TIA 568A dan ujung yang satu nya lagi menggunakan urutan kabel TIS/EIA 568B dan digunkan untuk menghubungkan PC ke PC, Switch/Hub ke Switch/Hub, dan PC ke Router.