Page 1: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

COLUMN CHROMATOGRAPHY(CC)

Page 2: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

TLC - Optimizing for column chromatography

Optimum: 0.2 < Rf < 0.5

Page 3: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

Column chromatography (CC) is an extremely valuable technique for purification of synthetic or natural products.

Compounds are separated by CC through the same mechanism as TLC;

through differential intermolecular forces between the components of the mixture with the mobile phase, and between the components with the stationary phase.

A variety of adsorbents can be used as the stationary phase;

silica gel (which is very polar) is most commonly used in organic chemistry.

COLUMN CHROMATOGRAPHY

Page 4: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

Polar components (b) adsorb more strongly to the polar silica and elute after the less polar components (a), which move more quickly with the non-polar (relative to silica) solvent.

COLUMN CHROMATOGRAPHY

Page 5: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

COLUMN CHROMATOGRAPHY

Skoog and Leary: Principals of Instrumental Analysis, 4 th ed. Suanders, 1992

Page 6: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

FLASH COLUMN CHROMATOGRAPHY

Page 7: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

FLASH COLUMN CHROMATOGRAPHY

• Build column• Apply sample• Elute • Collect Fractions• Analyze by TLC• Combine pure fractions

Page 8: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

FLASH COLUMN CHROMATOGRAPHY

Page 9: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

FCC - OPTIMIZATION

Measure of column efficiency

Page 10: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

FCC – Sample vs Column Size

Page 11: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

TLC vs High Performance Liquid Chromatography (HPLC)

Page 12: COLUMN CHROMATOGRAPHY (CC). TLC - Optimizing for column chromatography Optimum: 0.2 < R f < 0.5

http://www.labhut.com/education/flash/introduction07.php

TLC vs High Performance Liquid Chromatography (HPLC)