Combustible Gas Leak Detector The D540 utilizes a solid state heated sensor designed for high sensitivity to all combustible gases including Methane (Natural Gas), Propane, Butane, Ethane (R170), Acetylene, Methanol, Acetone and Gasoline. MSHA Certified as Intrinsically Safe. Inspect furnaces, gas appliances and gas lines fast and safely. Also use to find leaks in fuel and exhaust systems plus verify integrity of fuel storage containers. The unique digital display allows for quick, precise pinpointing of the leak source and also determines the size of the leak. Housed in rugged high impact ABS plastic.
Part # 53-D-540Description Leak Detector; Combustible GasSensitivity <10 ppm (methane) Sensor Life >300 hoursResponse Time InstantaneousPower Supply 4 AA Alkaline batteries (included)Battery Life 20 hours continuousWarm Up Time <10 secondsProbe Length 43cm (17”)Numerical Display 1 to 9Weight 0.58kg (1.5lbs)Warranty 2 years (includes sensor)
SPECIFICATIONS
FEATURES • Long life, stable sensor• Unique numeric leak size
indicator & alarm• Automatic calibration and reset
to ambient levels• 3 adjustable sensitivity levels• Low battery indicator• Audio mute function• Comfortable sanoprene grip• MSHA Intrinsic Safety Certified• CE Certified• Made in USA• 2 Year Warranty (includes sensor)
Detectable Gases (Partial List)Methane, Propane, Ethane,Butane, Hydrogen, Ethylene, ISO-Butane, NOL, Gasoline,Acetylene, Ammonia, H. Sulfide,Industrial Solvents, Alcohol,Acetane, Foluene, Xylene.
53-D-540
Storage case included
RED HOTPRICING!
ORDER NOW!
alltemp heating special 08/092
2008/09 Heating Specialwww.alltemp.ca
Heat SequencersFeatures
• Solid State PTC Heaters• Quick-Connect Terminals• Shock & Vibration Resistant• Mounts in any position• Contact Ratings - to 25 Amps at 120 or 240 Volts, and 12.5A at 480 Volts• Full-Load Rated Auxilliary Contacts• Standard Operating Ambience Between -50°F (-45.5°C) and 165°F (73.8°C)
Notes• M1-M2 and M3-M4 are always the first switches to turn on and the last to turn off. All other switches are random on and random off.• ON TIME - Elapsed time to make contacts after heater is energized• OFF TIME - Elapsed time to make contacts after heater is de-energized• OFF timings determined after PTC heater has been electrified for a total of 5 minutes• Standard Timings determined at 25°C. Timings at temperatures above or below 25° will vary
Combined Load Ratings (all models): 30A @ 240 VAC - Total: 23 A non-inductive + 7 FLA/42 LRA Inductive Life at rated current: 100,000 cycles
Heater Pole24 Vac 0.18A (anticipator)0.75A Max Inrush0.16 to 0.20 amps Steady StateAmbient Rating: - 50° to 160°F
Applications• Electric Furnaces• Baseboard Heaters• Duct Heaters• Suspension Heaters• Recreational vehicle blower and element control• Heat pump blower and heating element control• Motor speed switching in air conditioning ( high speed ) / heating systems (low speed) where a single set of contacts handle combination motor and heater element loading in the heater function• Control circuts requiring definate sequence on both start up and shut downStandard Timings
Electrical Ratings
Part # Timings Switches Timings (seconds) - On Timings (seconds) - Off
M1- M2
M3- M4
M5- M6
M7- M8
M9- M10
M1- M2
M3-M4
M5-M6
M7-M8
M9-M10
HS-24A34-21 1 1 1-20 1-60
HS-24A34-22 1 1 15-45 1-30
HS-24A34-23 1 1 25-60 15-45
HS-24A34-24 1 1 30-90 1-40
HS-24A34-25 1 1 30-90 1-30
HS-24A34-26 2 2 1-20 30-90 40-90 1-30
HS-24A34-27 3 1 1-160 1-160
HS-24A34-29 1 1 15-35 25-55
HS-24A34-36 2 2 1-20 30-90 45-110 1-30
HS-24A34-37 3 1 1-110 1-110
VACResistive (non-inductive) Motor ratings (inductive) Pilot
DutyWatts Amps Full Load Locked Rotor
120 3000 25.0 10.0A 60.0A 125VA
240 6000 25.0 5.0A 30.0A 125VA
480 6000 12.5 3.0A 18.0A 480VA
NEW!
HS-24A34-21, 22, 23, 24, 25 HS-24A34-29 HS-24A34-26, 27, 36 HS-24A34-37
alltemp heating special 08/09 3
2008/09 Heating Specialwww.alltemp.ca
One Pole Contactors• One pole contactor with shunt • UL, CSA, CE Approved• 4 - 1/4" Brass Spade Terminals Per Power Connection• #10-32 Combination Screw Terminals• 50/ 60 Hz
Part #Full Load
Amps.Coil Voltage
50/60Resistive
Amps.Locked Rotor Amps.@240V
Height Width Depth
HC-13024 30 24 40 150 2.39" 2.00" 3.29"HC-130120 30 120 40 150 2.39" 2.00" 3.29"HC-130240 30 208/240 40 150 2.39" 2.00" 3.29"
Two Pole Contactors• UL, CSA, CE Approved• 30 Amp.= 4 - 1/4" Brass Spade Terminals Per Power Connection• 40 Amp.= 4 - 1/4" Copper Spade Terminals Per Power Connection• 50/ 60 Hz• Contact Cover Over Contacts (40 Amp Models & Up)
Part #Full Load
Amps.Coil Voltage
50/60Resistive
Amps.Locked Rotor Amps.@240V
Height Width Depth
HC-23024 30 24 40 150 2.45" 2.00" 3.29"HC-230120 30 120 40 150 2.45" 2.00" 3.29"HC-230240 30 208/240 40 150 2.45" 2.00" 3.29"
HC-24024 40 24 50 200 2.63" 2.00" 3.29"HC-240120 40 120 50 200 2.63" 2.00" 3.29"HC-240240 40 208/240 50 200 2.63" 2.00" 3.29"
HC-130241 Pole Contactor With Shunt Illustrated
HC-230242 Pole Contactor Illustrated
Definite Purpose Magnetic Contactors
Contactor Terminal Types• 30 Amp. = #10-32 Combination Screw
Terminals.• 40 Amp. = # 14-4 Aluminum Compression Lug
Terminals With 1/4"-20 Screws.• 50 - 60 Amp. = # 14-2 Aluminum Compression
Lug Terminals With 1/4"-20 Screws.• 75 - 90 Amp. = # 14-1 Aluminum Compression
Lug Terminals With 1/4"-20 Screws.Custom Terminal Type Models Available
Upon Request!
Rotom Definite Purpose Magnetic ContactorsContactors are designed to establish or interrupt a power circuit. Definite purpose contactors unlike general purpose contactors are non-rebuildable electronic controls designed for specific application with clearly defined operating condi-tions.
Auxiliary Switch.HC-600
Auxiliary Switch.HC-250 (One Switch)
HC-500 (Two Switches)
Auxiliary Contact Switches• Clips Directly Onto Either End Of Any Rotom Contactor• 1/4" Quick Connect Terminals• Snap Fast Action Switch• UL & CSA Approved When Used With UL & CSA Approved Rotom Contactors
Part #Contactor
FLAContinuous
Amps.Voltage Rating
Description Height Width Depth
HC-250 30 & 40 10 300 1 × SPDT, N.O. & N.C. 2.81" 2.61" 0.67"HC-500 30 & 40 10 300 2 × SPDT, N.O. & N.C. 2.81" 2.61" 0.67"
HC-600* 30 & 40 10 6002 Contacts × 1 Pole, N.O
(make) or N.C. (break)2.77" 3.13" 0.70"
HC-300 50 & 60 10 300 1 × SPDT, N.O. & N.C. 2.00" 1.34" 0.79"* 6-32 Screw Terminal Model Available - Order Part # HC-600S
Auxiliary Switch.HC-300
FEATURES:• Compact size.• Quieter than traditional designs.• Far more efficient operation.• Universal electrical connections.• Quick connect terminals.• Universal galvanized mounting plates.• Protective contact cover.
• Snap on auxiliary contacts.• Individually labelled & packaged.• Easy to understand part numbers.• Complete cross reference.• cURus, UL, CSA & CE approved.• Price competitive.
alltemp heating special 08/094
2008/09 Heating Specialwww.alltemp.ca
Three Pole Contactors• UL, CSA, (CE 30 - 60 Amp)• 30 Amp.= 2 - 1/4" Brass Spade Terminals Per Power Connection• 40 Amp.= 2 - 1/4" Copper Spade Terminals Per Power Connection• 50 - 90 Amp.= 2 - 1/4" Copper Spade Terminals & Aluminum Lug Per Power
Connection• 50/ 60 Hz• Contact Cover Over Contacts (30 - 40 Amp Feature Built-In Test Button)
Part #Full Load
Amps.Coil Voltage
50/60Resistive
Amps.Locked Rotor Amps.@240V
Height Width Depth
HC-33024 30 24 40 180 2.99" 2.37" 3.75"HC-330120 30 120 40 180 2.99" 2.37" 3.75"HC-330240 30 208/240 40 180 2.99" 2.37" 3.75"
HC-34024 40 24 50 240 2.99" 2.37" 3.75"HC-340120 40 120 50 240 2.99" 2.37" 3.75"HC-340240 40 208/240 50 240 2.99" 2.37" 3.75"
HC-35024 50 24 65 300 3.62" 2.75" 4.00"HC-350120 50 120 65 300 3.62" 2.75" 4.00"HC-350240 50 208/240 65 300 3.62" 2.75" 4.00"
HC-36024 60 24 75 360 3.62" 2.75" 4.00"HC-360120 60 120 75 360 3.62" 2.75" 4.00"
HC-360240 60 208/240 75 360 3.62" 2.75" 4.00"
HC-37524 75 24 90 450 4.05" 3.75" 5.18"
HC-375120 75 120 90 450 4.05" 3.75" 5.18"
HC-375240 75 208/240 90 450 4.05" 3.75" 5.18"
HC-39024 90 24 120 540 4.05" 3.75" 5.18"
HC-390120 90 120 120 540 4.05" 3.75" 5.18"
HC-390240 90 208/240 120 540 4.05" 3.75" 5.18"
Four Pole Contactors• UL, CSA, CE Approved• 30 Amp.= 2 - 1/4" Brass Spade Terminals Per Power Connection• 40 Amp.= 2 - 1/4" Copper Spade Terminals Per Power Connection• 50/ 60 Hz• Contact Cover Over Contacts With Built-In Test Button
Part #Full Load
Amps.Coil Voltage
50/60Resistive
Amps.Locked Rotor Amps.@240V
Height Width Depth
HC-43024 30 24 40 180 2.99" 2.75" 3.75"
HC-430120 30 120 40 180 2.99" 2.75" 3.75"
HC-430240 30 208/240 40 180 2.99" 2.75" 3.75"
HC-44024 40 24 50 240 2.99" 2.75" 3.75"
HC-440120 40 120 50 240 2.99" 2.75" 3.75"
HC-440240 40 208/240 50 240 2.99" 2.75" 3.75"
Contactor NomenclatureHC - 1 30 24
HC = Product Code1 = Poles (1, 2, 3 or 4)30 = Full Load Amps. (30A, 40A...)24 = Coil Voltage (24, 120 or 240)
Typical Applications• Heating• Ventilation• Air Conditioning• Refrigeration
- Compressors- Motors
• Agriculture • Pool & Spa Controls• Food Service Equipment• Welding Equipment• Business Machines
HC-330243 Pole, 30-40 Amp
Illustrated
HC-440244 Pole Contactor Illustrated
Definite Purpose Magnetic Contactors
HC-3601203 Pole, 50-90 Amp
Illustrated
alltemp heating special 08/09 5
2008/09 Heating Specialwww.alltemp.ca
Totally Enclosed Fan Relays - Heavy Duty
General Purpose Fan Relays - Standard DutyFeatures Designed for switching single or two speed fan motor, relays,
solenoids, resistive loads in cooling, heating or general pur-pose switching applications.
• Replace WR/ Essex/ RBM & Mars type 84 models• Totally enclosed compact design.• Quiet & reliable operations.• UL & cUR (file E44211)• Universal mounting bracket.
Features Designed for cooling, heating or general purpose switching
equipment operating heavier loads.• Replace WR/ Essex/ RBM & Mars type 184 models• Totally enclosed compact design.• Quiet & reliable operations.• Universal mounting bracket• UL & cUR (file E44211)• SPST, SPDT & SPNO/SPNC models.
Specifications• Temperature Range: -20°C (-4°F) to 40°C (104°F).• Mechanical Life: 1,000,000 operations.• Electrical Life: 100,000 operations (@ 25amp 277VAC Res.)• Operate Time (typical): 25 ms at nominal coil voltage.• Release Time (typical): 25 ms at nominal coil voltage.• Dielectric Strength (at sea level for 1 min.):- 2500 Vrms coil to contact.- 1000 Vrms between open contacts.• Coil Frequency: 50/60 Hz.• Coil Insulation: Class A (105°C / 221°F).• Coil Duty Cycle: Continuous.• Terminals: ¼" quick-connects.• Contact Material: Silver cadmium oxide.• Enclosure: Phenolic.
Specifications• Temperature Range: -20°C (-4°F) to 40°C (104°F).• Mechanical Life: 1,000,000 operations.• Electrical Life: 100,000 operations (@ 16amp 240VAC Res.)• Operate Time (typical): 25 ms at nominal coil voltage.• Release Time (typical): 25 ms at nominal coil voltage.• Dielectric Strength (at sea level for 1 min.):- 2500 Vrms coil to contact.- 1000 Vrms between open contacts.• Coil Frequency: 50/60 Hz.• Coil Insulation: Class A (105°C / 221°F).• Coil Duty Cycle: Continuous.• Terminals: ¼" quick-connects.• Contact Material: Silver cerium• Enclosure: Phenolic.
Totally Enclosed Relay - 2 Pole HVAC Switching Relays
Heavy Duty Relays
Coil Voltage
DPDTPart #
Terminals 1,2,3.
Terminals 4,5,6.
Resistance DC OHMS
±10%
Nominal Current
MA
Nominal VA
Sealed Max.
Inrush VA
Max.
Cross Reference
WR/RBM
Honeywell Mars
24 25-90340Power Power
15 334
8 21.5
90-340 R4222B1082 90340
120 25-90341 400 66 90-341 R4222B1090 90341
240 25-90342 1415 38 90-342 R4222D1013 90342
Features Intended for many applications in air conditioning, refrigeration,
heating and general purpose switching.• Replaces Honeywell, White-Rodgers/RBM & Mars (cross refer-
ence in packaging)• Semi-enclosed compact design.• Quiet & reliable operations.• Universal mounting bracket• Molded terminal numbers and circuit diagram on top of relay.• UL & cUR (file E44211).• 2 Pole DT mode
Specifications• Temperature Range: -40°C (-40°F) to 54°C (130°F).• Mechanical Life: 750,000 operations.• Electrical Life: 100,000 operations.• Coil Frequency: 50/60 Hz.• Coil Insulation: Class B.• Coil Duty Cycle: Continuous.• Terminals: ¼" quick-connects.• Contact Material: Silver cadmium oxide.• Enclosure: Phenolic.• Dimensions 2.13" × 1.88" × 2.25".
25-90340Illustrated
25-90380Illustrated
25-90290Illustrated
Contact Rating- 125/250 VAC
FLA LRAInductive
AmpsResistive
Amps
8 188 Amp
Continuous16 Amp
Continuous
Heavy Duty Relays Coil
VoltageSPSTPart #
SPDTPart #
SPNO-SPNC*Part #
Coil Resistance DC OHMS
±10%
Nominal Current
MA
Nominal VA
Sealed
Inrush VA
24 25-90360 25-90370 25-90380 77 167
4 4120 25-90362 25-90372 25-90382 2,000 33
240 25-90364 25-90374 25-90384 7,200 17
*Isolated Contacts
Contact Rating
VAC Amps FLA LRAInductive
AmpsResistive
Amps
125VAC
25
14 84 14 Amp Continuous25 Amp
Continuous@ 277 VAC
250VAC 8 48 8 Amp Continuous
277VAC 7 42 7 Amp Continuous
Contact Rating
VACAmps
General Use
HP LRA FLA
125V
153/4
82.8 13.8208V 45.6 7.6250V 41.4 6.9277V - 36.0 6.0
Single Pole HVAC Standard Duty RelaysCoil
VoltagePart #SPST
Part #SPDT
Coil Resistance DC OHMS
±10%
NominalCurrent
MA
NominalVA
Sealed
Inrush VA
24 25-90290 25-90293 90 146
3.5 4120 25-90291 25-90294 2,000 29
240 25-90292 25-90295 7,200 15
alltemp heating special 08/096
2008/09 Heating Specialwww.alltemp.ca
SPECIALLY DESIGNED FOR LOW VOLTAGE CONTROL APPLICATIONS IN THE INDUSTRIAL HEATING & COOLING INDUSTRY!
Features• Compact superior design.• Individually boxed with instructions.• Includes necessary mounting hardware.• Complete cross-reference.
Control TransformersControl Transformers
Control transformers are designed for use in 2.5, 12 or 24 volt al-ternating current (AC) control systems, including air conditioning circuits, thermostats, gas valves, relays and or other applications that do not exceed the listed ratings. These transformers can be used to replace any transformers of the same primary voltage and equal or smaller VA ratings.
25-52C6Mounting Plate
& Hardware
Foot Mount
Part # VA Primary VoltageSecondary
Voltage Connections34-20241 20 120 24 Wire34-40244 40 120 24 Wire34-40245 40 120/ 208/ 240 24 Wire34-40240W 40 240 24 Wire34-50254 50 575 24 QC
Multi Mount (Foot, Plate, Conduit)• 34-52C6 mounting plate, (2) screws & (2) wire connec-
tors included.
Part # VA Primary VoltageSecondary
Voltage Connections34-40241 40 120 24 Screw34-40242 40 208/ 240 / 277 24 Screw34-40243 40 120/ 208/ 240 24 Screw34-48003 48 120/ 208/ 240 2.5 / 12 / 24 Wire34-50243 50 120/ 208/ 240 24 Wire
Foot MountHeavy Duty (c/w Circuit Breaker)
Part # VA Primary VoltageSecondary
Voltage Connections34-75241 75 120 24 Wire34-75244 75 120/ 208/ 240/ 480 24 Wire34-10244 96 120/ 240/ 277/ 480 24 Wire
34-20241
34-4024434-40245 Illustrated
25-7524125-75244 Illustrated25-10244
25-FA112Optional
Mounting Plate
34-40240W Illustrated
25-40241 Illustrated25-40242 (4-wire)25-40243 25-48003 Illustrated
25-50243
NEW!
alltemp heating special 08/09 7
2008/09 Heating Specialwww.alltemp.ca
Features• 30A and 50A switching capabilities• .250" quick connect termination• Safety timer• Approvals: UL, CSA, cUL pending• Single, wire-for-wire replacement for ALL standard potential relays; save thousands on inventory management costs while making sure you have the
right part on hand at all times! • Patented differential voltage sensing eliminates the
need to set dials or make other field adjustments; automatically senses correct voltage needed to ensure a precision start every time - regardless of motor wear! • Enhanced, patent-pending circuitry protects the
compressor by safely and intelligently discharging stray D.C. voltage from the start cap to prevent welding of contacts.
• Non-positional mounting configuration and universal mounting bracket simplify installation.
• American-made quality and reliability! • Ideal for A/C, commercial refrigeration, heat pump, or
any single-phase motor application up to 10HP.
Enhanced Series UMSRe
SpecificationsInput:• Voltage Rating: 110-270 VAC, Single Phase• Maximum Voltage Contact Rating: 502 VAC (absolute)• Motor Power Rating: Up to 10 HP• Operating Position: Non-positional• Safety Time Out: Approximately 1-second per microfarad• Consumption: 5VA max.• Insulation: Class B (130°C); Conforms to IEC 1000- standards (6kV impulse / 6kV contact)• Life Expectancy (minimum operations) Mechanical: 1 x 106
Electrical: 1 x 106 at 16A 400VAC• 5 x 105 at 35A 400VAC (break only)• 5 x 105 at 50A 400VAC (break only)Contacts:• Contact Rating: 30A (break only), 400 VAC cos Ø = 0.7 to 0.8 50A (break only), 400 VAC cos Ø = 0.7 to 0.8
ICM’s new Universal Motor Starting Relay incorporates patented differential voltage sensing and a non-positional mounting configuration to offer a single replacement for all standard potential relays. The UMSRe features advanced circuitry that intelligently discharges stray D.C. voltage from the starting capacitor to prevent contactor welding under extreme circumstances.
Standard Wiring Diagram
Alternative ReducedArcing Configuration
All Features and Specfications Subject to Change Without Notice
Wire-For-Wire Replacement For All Standard Potential Relays!Intelligent capacitor discharge circuitry provides anti-weld protection.
Part # Amps
24-UMSRE30 30
24-UMSRE50 50 NEW!
Dimension Diagrams
alltemp heating special 08/098
2008/09 Heating Specialwww.alltemp.ca
Relay/Transformer Fan Centre AssemblyFan centre controls provide convenient low voltage control of one and two speed fan motors and auxiliary circuits in heating, cooling or heating/cooling applications. Each fan centre control is a reliable, compact unit consisting of a 24 volt control trans-former and a plug-in switching relay mounted on a 4" square electrical junction box cover. All line voltage connections are made inside the box with colour coded pre-stripped leads. Low voltage connections are made at a convenient terminal board mounted to the transformer.
Fan Control CentreFeatures
• DPDT or SPDT relay.• 24V coil voltage, power and duty rated
contacts.• Colour coded pre-stripped leads.• Low voltage terminal board.• Input Voltage 120V or 208/240V, Output
Voltage - 24V, 40 VA.• Mounts directly to 4" electrical box.• UL/ CUR File E237660.
Fan Control CentreTransformer Relay Contact Ratings
Part #Primary Secondary Full
Relay
120 VAC (amps)
240 VAC (amps) Resistive Cross Reference
Voltage Connection Voltage Connection LRA FLA LRA FLA
25-90113 120Colour coded pre-stripped
leads.24 V
Terminal board with 5 screw
terminals.DPDT 13.8 82.8 6.9 39.6
15 Amps @ 277 VAC.
Honeywell: R8285 Series.Mars: 90113.White Rodgers: 8A05A-101.
25-90113Illustrated
Features• Controls oil burner, oil valve (if desired) and the ignition transformer
in response to a call for heat .• Solid state flame sensing circuit .• LED on terminal strip indicates system lockout.• Enclosed safety switch with external reset button.• Mounts on standard 4" x 4" junction box; select models may be
mounted directly on burner housing.• 69-45610 Cadmium Sulfide Flame Detector and 24 VAC thermostat
required.• Direct replacement for popular competitive models.
Oil Primary Control - Intermittent IgnitionPart # Safety Timing Replaces
24-ICM1501 15 Sec Honeywell: R8184G4066, R8184G1161, R8184G1294
24-ICM1502 30 Sec Honeywell: R8184G4074, R8184G1179, R8184G1302, R8184G4033
24-ICM1503 45 SecCarlin: 48245 - Tempstar/Heil: 1147017 - White Rodgers: 668-401Honeywell: R8184G4009, R8184G1138, R8184G1427, R8184G4025
Oil Primary Control - Interrupted IgnitionPart # Valve on Delay (Seconds) Burner Motor Off Delay (minutes) Alarm Contacts Replaces
24-ICM1511 Selectable 0 - 15 Selectable 0 or 2,4,6 Yes Honeywell:R7184U
24-ICM1512 15 0,2,4,6 or 0.5,2,4, or 8 Optional Honeywell:R7184P
24-ICM1513 15 None None Honeywell:R7184B
24-ICM1514 None None None Honeywell:R7184A
Oil Primary ControlSpecifications
Ignition Type: Intermittent Timing, Safety Switch: 15, 30 or 45 seconds Mounting Bracket: For mounting on a standard 4" × 4" junction box or direct mounting on burner housing.Electrical Rating; Contacts (full load):7.4 A @ 120 VAC; 3.7 A @ 240 VAC Electrical Rating; Contacts (locked rotor):44.4 A @ 120 VAC; 22.2 A @ 240 VAC Dimensions:• 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep • 111 mm high x 104 mm wide x 64 mm deep Temperature Range: -30°F to +130°F Approvals • Underwriters Laboratories Inc
Dimensions
4.08"3.38"
2.35"2.03"
3.38"
4.41"
ø .18"
Thermostats - Fixed Temperature
3 Wire Fixed ThermostatsSwitched fan, 3 modes: • Fan Only• Off• Heat or Cool
Part # Description78-SC060S 60°F w/ switch - fan/off/ heat.78-SC065S 65°F w/ switch - fan/off/ heat.78-SC070S 70°F w/ switch - fan/off/ heat.78-SC075S 75°F w/ switch - fan/off/ cool.
2 Wire Fixed ThermostatsPart # Description
78-SC045 45°F cool.78-SC055 55°F cool.78-SC060 60°F heat.78-SC065 65°F heat.78-SC070 70°F heat.78-SC075 75°F cool.
Specifications Electrical Rating • 24 volt AC (18-30 VAC) • 2 amp maximum Temperature Control Ranges • Accuracy ±5°F 55°, 60°, 65°, 70°, 75°F
"Dry Out"
Thermostats
Fixed Temperature Thermostats• The 78-SC055 to 78-SC075S series of thermostats are low cost single set point
thermostats intended for temporary heating or cooling to allow drywall to dry during construction. Can also be used for low ambient cut-off switch.
• Rugged utility thermostat for temporary applications.• Ideal for new or ongoing construction areas.• Five fixed set point models to choose from (55°, 60°, 65°, 70°, 75°F).• Hardwired.
78-SC075 Illustrated 78-SC075S
Illustrated
Applications• Ideal for warehouses &
new home construction!
NEW!
alltemp heating special 08/09 9
2008/09 Heating Specialwww.alltemp.ca
Fan Blower Controls
Off Delay on BreakControls the circulating fan in heat pump, air conditioning and forced air systems. OFF delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby purging the ducts of residual air and increasing system efficiency.
Dual On/Off DelaysControls the circulating fan in heat pump, air conditioning and forced air systems. Delay on make lets air reach proper level prior to turning the fan on. OFF delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby purging the ducts of residual air and increasing system efficiency.
Part # Features and Applications Specifications Replaces
24-ICM253
· UL 873 recognition for compressor applications· Post-purge fan delay timer
· Interrogation delay eliminates nuisance trips due to thermostat bounce/tampering
· Voltage:18-30VAC· 1 Amp Max· 40 mA Min.· 10 Amp Inrush· Adjustable time delay 12-390 seconds· Dimensions: 2"×3"
· Field Controls: 46144700· Gemline: 1C216· Mars: 32393
Part # Features and Applications Specifications Replaces
24-ICM251· Drives fan directly
· High power, relay output· Dual function fan relay timer
· Voltage:18-30VAC· Output: N.O.: 20 Amps @ 240VAC N.C.:10 amps @ 240VAC· Time Delays Adjustable On - 1-180 seconds Off - 12-390 seconds· Dimensions: 2"×3"
· Mars: 32377, 32378, 32379
24-ICM254
· Dual function fan timer· Controls the circulating fan in heat pump, A/C and
forced air systems
· Voltage:18-30VAC· 1 Amp Max· 40 mA Min.· 10 Amp Inrush· Time Delays Adjustable On - 1-180 seconds Off - 12-390 seconds· Dimensions: 2"×3"
· Honeywell: S876A1016· Watsco: PSTD-00-005W, PSTD-00-060W
24-ICM255
· Low cost open board design· High power, relay output
· Dual function fan delay timer
· Voltage:18-30VAC N.O.: 20 Amps @ 240VAC N.C.:20 amps @ 240VAC· Time Delays Fixed On - 1 second Off - 60 seconds· Dimensions: 2.5"×2.5"
· A-1: 5893· Bard: 8201-056· Mars: 32393· Rheem: 42-22515-01, 02, 03· Snyder General/ICP: 1395336
24-ICM251 24-ICM254 24-ICM255
24-ICM253
alltemp heating special 08/0910
2008/09 Heating Specialwww.alltemp.ca
Fan Blower Controls
Part # Features and Applications Specifications Replaces
24-ICM270
· Dual function fan delay timer · Controls the circulating fan in a heat pump,
A/C and forced air systems · OFF delay purges ducts of residual air · ON delay allows air to reach the proper
comfort level prior to energizing the fan
Voltage: 18-30 VACFrequency: 50/60 HzHeat/Cool SpeedN.O.: 20 amps @ 240 VACN.C.: 10 amps @ 240 VACTime Delays Blower Off Time Adjustable90,120,150,180 seconds
· Evcon: 2702-300· Rheem: 47-22827-01, 81, 82, 47-22828-01, 02· Robertshaw: 695-003
24-ICM271
· Specifically designed to replace popular gas furnace centers
· Pin selectable blower delays · High power, relay output
· Dual function fan delay timer · Controls the circulating fan in heat pump, A/C
and forced air systems · OFF delay purges ducts for residual air · ON delay allows air to reach the proper
comfort level prior to energizing the fan
Voltage: 18-30 VACFrequency: 50/60 HzContact RatingsN.O.: 20 ampsN.C.: 10 ampsFixed Time DelaysON: 75 secondsOFF: 105 seconds
· Carrier: 302075-3, CES00110017/0018, HH84AA010/011/012 /013/020 P771-7002· Robertshaw: 695-100
24-ICM272
· Cooling control module with fan delay · Integral low voltage terminal board with field
thermostat wiring · Electronic air cleaner output
· High power, relay output · DC output for fan relays and 1st stage of
electric heater control · Interlock circuitry prevents 2nd and 3rd stage
electric heat energization without proper fan operation
Voltage: 18-30 VACFrequency: 50/60 HzContact RatingsN.O: 20 ampsN.C.: 10 ampsTime Delay Fixed60 seconds
· Carrier: HK61GA001/003· Texas Instruments: 2FD-1
24-ICM273
· Solid state output · Silent operation, \\\"no clicking\\\"
· Controls the circulating fan in heat pump A/C and forced air systems
· OFF delay purges ducts of residual air
Voltage: 18-30 VACFrequency: 50/60 HzOutput2 amps @ 240 VACTime Delay Fixes60 seconds
· EMI: 240000-969
24-ICM274
· Microprocessor-based fan blower control· Built in humidity relay
· Manually adjustable post-purge offdelay from 60-240 seconds
Voltage: 18-30 VAC - Y out: 1.5 amps - Fan: 2 amps - Electric heat relay: 30 amps @ 240 VAC - Blower off delay: 60 seconds
· EMI: 240-1764
24-ICM275
· Microprocessor-based fan blower control · Built in humidity relay
· Manually adjustable post-purge off delay from 60-240 seconds
· Electronic air cleaner output
Voltage: 18-30 VACFrequency: 50/60 HzContact Ratings:20 amps @ 240 VAC on high10 amps @ 240 VAC on lowTime DelaysON: 60 seconds fixedOFF: 60-240 seconds adjustable
· Carrier: CES0110019, HH84AA001/003/005/009/ 014/015/021· Robertshaw: 695-101
24-ICM276
· Microprocessor-based fan blower control· Inducer fan outputs
· Controls the circulating fan in gas/heat and A/C systems
· OFF delay purges ducts of residual air
Voltage: 18-30 VACOutput: - Fan:20 amps @240 VAC - Inducer fan: 2 ampsTime Delays (seconds) - Heat on delay: 60 - Heat off delay:120,150,180 - Cool off delay:60
· Carrier: HK51GA003· Rheem: 47-23619-02/03· Robertshaw: 457-23619-03 RS100-833-02
24-ICM277 · Microprocessor-based fan blower
· Controls the circulating fan in heat pump, A/C and forced air systems
Voltage: 18-30 VACContact RatingsN.O.: 20 ampsN.C.: 10 ampsTime DelaysON: 7 secondsOFF: 65 seconds
· Goodman: B13707355
Direct OEM Replacement Parts
NEW!
NEW!
alltemp heating special 08/09 11
2008/09 Heating Specialwww.alltemp.ca
Freeze Protection Modules
Furnace Controls
Applications The ICM308/309/310 are low cost, fixed, single setpoint temperature controls that provide freeze protection.
Part # Temperature Cut Out (OFF) Temperature Cut In (ON)
24-ICM308 43°F 45°F
24-ICM309 28°F 55°F
24-ICM310 44°F 48°F
Part # Features and Applications Specifications
24-ICM30824-ICM30924-ICM310
· Low cost, fixed, single setpoint temperature controls that provide freeze protection
· Small compact package· Epoxy encapsulated for moisture protection
· Temperature sensor included
Input: - Voltage: 18-30 VAC - Frequency: 50-60 HzOutput - Solid state (triac)1.5 amps @ 30VACDimensions: - 2"×2"×1¼"
NEW!
Furnace Control Modules
Part # Features and Applications Specifications Replaces
24-ICM280
Low cost, direct replacement board for Goodman, Janitrol, TI, White-Rodgers and UTEC
Microprocessor based design for precise timing Functions with all 24 VAC thermostats
For 80+ and 90+ applications UL recognized
Voltage Range: Line (98 to 132 VAC) @ 60HzCool Blower: 10A, 2 HP, 240 VACHeat: 5A, 240 VACInducer Motor: 4A, FLA-8.0 LRA @ 120 VACGas Valve: 1.5A @ 30 VACHeat Blower on Delay: 30 secondsHeat Blower Off Delays: 90, 120 and 150 secCool Blower on Delay: 5 secondsCool Blower Off Delay: 60 seconds
· Goodman: B1809906/08/10/ 13/13S· UTEC:1012-933D· Texas Instruments: 41F-5· White-Rodgers: 50T35-730/743
24-ICM281
Low cost, direct replacement board for Carrier CESO11005700/01/02
Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner
Microprocessor-based for precise timing Functions with all 24 VAC thermostats
Designed for 100% gas shutoff in case of ignition failure Twinning compatible with another ICM281 board
Voltage Range: Line (98 to 132 VAC) @ 60HzCool Blower: 10A, 2 HP, 240 VACHeat: 5A, 1/2 HP, 240 VACInducer Motor: 4A, FLA-8.0 LRA @ 120 VACGas Valve: 1.5A @ 30 VACHeat Blower on Delay: 40 secondsHeat Blower Off Delays: 90, 135, 180, and 225 secondsFan (Low) On/Off: 1-secondCool Blower on Delay: 5 secondsCool Blower Off Delay: 90 seconds
· Carrier: CESO110057-00/01/02
24-ICM282
Low cost, direct replacement for Carrier HK42FZ004/007/008/009/011/013/016
Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner
Microprocessor-based Designed for 100% gas shutoff in case of ignition failure
Twinning compatible with another ICM282 board Diagnostic fault codes (blinking LED) to aid in troubleshooting
Voltage Range: Line (98 to 132 VAC) @ 60HzCool Blower: 10A, 2 HP, 240 VACHeat: 5A, 1/2 HP, 240 VACInducer Motor: 4A, FLA-8.0 LRA @ 120 VACGas Valve: 1.5A @ 30 VACHeat Blower On: 60 secondsHeat Blower Off: 90, 120, 150, and 180 secFan (Heat) On/Off: 1-secondCool On: 2 secondsCool Off: 90 seconds with jumper JW2 uncut; 5 seconds with jumper JW2 cut
· Carrier: HK42FZ004/007/008/009/ 011/013/016
24-ICM280 24-ICM281 24-ICM282
alltemp heating special 08/0912
2008/09 Heating Specialwww.alltemp.ca
Drain Valve• Non-corrosive glass filled polymer const.• Unlike brass, will not deplete anode sys.
Part # Description39-DV7575 3/4" NPT × 3/4" NPT male .
Water Heater Valve
Forged Gas Ball Valves• Brass or plated outdoor.• Yellow lever handle.• 600 WOG full port.
Brass Indoor Plated Outdoor Description06-FGV38 06-FGV38P 3/8" FNPT × 3/8" FNPT06-FGV12 06-FGV12P 1/2" FNPT × 1/2" FNPT06-FGV34 06-FGV34P 3/4" FNPT × 3/4" FNPT06-FGV1 06-FGV1P 1" FNPT × 1" FNPT06-FGV114 06-FGV114P 1¼" FNPT × 1¼" FNPT06-FGV112 06-FGV112P 1½" FNPT × 1½" FNPT06-FGV2 06-FGV2P 2" FNPT × 2" FNPT
Appliance Forged Gas Ball Valves• Brass ball valves.• Red wing handle.• 600 WOG.
Part # Description06-GWH12 1/2" FNPT × 1/2" FNPT, 3/8" port.06-GWH34 3/4" FNPT × 1/2" FNPT, 1/2" port.
Gas Cock Valves
Brass Welded Ball Valves• Full Port.• Female sweat connection.• 600 WOG.• Green lever handle.
Part # Description06-SWV12 1/2" Sweat × 1/2" Sweat.06-SWV34 3/4" Sweat × 3/4" Sweat.
Water Valves
Forged Boiler Gate Valve• Brass drain valve. • Green handle.
Part # Description06-BGV12 1/2" MNPT × Hose.06-BGV34 3/4" MNPT × Hose.
Boiler Drain Valves
Brass (Indoor) or
Plated (Outdoor)
Applications Fireplace Forged Gas Ball Valves• Brass ball valves.• Red wing handle.• 600 WOG.
Part # Description06-FP1238 1/2" FNPT × 3/8" Male flare.06-FP1212 1/2" FNPT × 1/2" Male flare.06-FP3458 3/4" FNPT × 5/8" Male flare.
Appliance Forged Gas Ball Valves• Brass ball valves.• Yellow flat head.• 600 WOG.
Part # Description06-FHGV12 1/2" FNPT × 1/2" FNPT, 3/8" port.06-FHGV34 3/4" FNPT × 3/4" FNPT, 1/2" port.
alltemp heating special 08/09 13
2008/09 Heating Specialwww.alltemp.ca
Ball BearingsBearings complete with collar.
Part # Bore OD Replaces67-4336-1
3/4" 1 13/16"LRCR
67-4336-2 (2) Bearings & (2) Collars
67-4346-1 1" 2 ¼" RCR
Sleeve Bearing PaksKits include 2 bearings & 2 rubber sleeves.
Part # Bore OD Type Replaces67-4036-2 3/4" 1 25/32"
OilDelhi
67-4046-2 1" 2 ½" Delhi
67-4135-2 5/8" 1 7/8"
Sealed
Lau
67-4136-23/4"
1 13/16"Delhi
67-4137-2 Lau & Lennox
67-4138-2 1 7/8" Torin
67-4146-21" 2 ½"
Delhi
67-4147-2 Lau & Lennox
67-4148-2 Torin
Bearings
Bearings & SleevesPart # Bore Type
67-4136-R 3/4" Rubber sleeve67-4146-R 1" Rubber sleeve67-4136-B 3/4" Sealed bearing67-4146-B 1" Sealed bearing67-4036-B 3/4" Oil bearing67-4046-B 1" Oil bearing
Thrust Collar PaksPart # Description
67-2164 (2) 5/8" collars & washers.67-2165 (2) 3/4" collars & washers.67-2166 (2) 1" collars & washers.
67-2165Illustrated
67-4136-RIllustrated
67-4136-BIllustrated
67-4046-BIllustrated
67-4036-2Oil Type Illustrated
67-4136-2Sealed Type Illustrated
67-4336-1Illustrated
Aluminum Pulleys
Variable Speed PulleysPart # Bore Diameter
67-4325
1/2"
3 1/4"67-4350 3 1/2"67-4375 3 3/4"67-4400 4"67-5325
5/8"
3 1/4"67-5350 3 1/2"67-5375 3 3/4"67-5400 4"Cast aluminum pulley mfg'd to OEM specs
Blower Pulleys - Continued
Part # Bore Diameter67-860
1"
6"67-870 7"67-880 8"67-890 9"67-810 10"67-812 12"
67-4325Illustrated67-660
Illustrated
ShaftsPart # Diameter Length Reference
67-61100
3/4"
11" Lennox, 210015767-61110 11 5/8" Lennox67-61212 12 3/4" 8-5-495C, 210000267-61400 14" 8-5-245C, 210015967-61550 15 5/16" G9, G12-9, 210016067-61600 16" 8-6-23608, WW15X36, 2100162, 2100163, 210019867-61610 16 5/8" 8-5-240C, G10, G110, 2100011, 210016167-61800 18" 8-5-247C, 8-5-241C, 2100012
67-61920 19 1/8" G12, 2100168
67-62000 20" M90-256, RS62067-62200 22" 210001367-62400 24" 8-5-243C67-63600 36"67-82000
1"20" G15-72, 2100165, 2100078, 2100081, 2100076
67-82400 25" 8-5-252C & 255C, M90-257, G15, 2100037, 55, 56, 210016667-83600 36" P-S-209, M90-270, 2100168, 2100052, 210054
Shafts
Shafts• Sized to bearing manufacturers
specifications.• Slabbed on pulley end.• Rust protected.• Individually wrapped.• Protective end caps.• Part number and
size listed on every shaft.
67-61610Illustrated
Blower PulleysPart # Bore Diameter
67-650*
3/4"
5"67-660 6"67-670 7"67-680 8"67-690 9"67-610 10"67-612 12"
* 5" pulley is solid
alltemp heating special 08/0914
2008/09 Heating Specialwww.alltemp.ca
Combustion Chamber Liners
63-3WETPAKWet Pak Sheet
63-D11Illustrated
63-DP9, DP11, DP13 & DP15
Models
63-DP16 & DP20Models
63-10WETPAKPreshaped Wet Pak
Wet Paks• Seamless design complete with a bottom.• Pliable yet self supporting in a vertical position.
Pre Dried• Formed to a uniform thickness & density while maintaining a
hardness which has exceptional handling strength.• Easy to cut means more versatility in nozzle opening placement.
Features:• Fast easy installation - less than 30 min.• Low conductivity - high efficiency.• High sound absorption.• Lightweight: 5% of conventional firebrick.• High heat resistance (up to 2300°F).• Superior to steel brick or castable cham-
bers.• Individually sealed & packaged.• Comes with instructions.• Wall thickness 1/2" nominal.
Preshaped Wet Paks
Part # G.P.HInside
DiameterOutside Diameter
Height Weight
63-09WETPAK 0.50 to 0.75 8" 9" 15.5" 4.0 lbs.63-10WETPAK 0.75 to 1.00 9" 10" 15.5" 5.0 lbs.63-11WETPAK 1.00 to 1.25 10" 11" 15.5" 6.0 lbs.63-12WETPAK 1.25 to 1.50 11" 12" 15.5" 6.5 lbs.63-13WETPAK 1.50 to 2.00 12" 13" 15.5" 7.0 lbs.63-14WETPAK 2.00 to 2.50 13" 14" 15.5" 7.5 lbs.63-16WETPAK 2.50 to 2.75 15" 16" 15.5" 8.5 lbs.
Pre Dried
Part # G.P.H.Inside Diam-
eterOutside Diameter
Height Weight
63-D09 0.50 to 0.75 8" 8" 12.25" 2.25 lbs.63-D10 0.75 to 1.00 9" 10" 12" 3.0 lbs.63-DP09 0.65 to 0.85 9" 10.5" 15" 5.0 lbs.63-D11 1.00 to 1.25 10" 11" 12" 3.5 lbs.63-DP11 1.00 to 1.25 11" 12.5" 15" 6.5 lbs.63-D12 1.25 to 1.50 11" 12" 14" 4.0 lbs.63-D13 1.50 to 2.00 12" 13" 14" 4.25 lbs.63-D14 2.00 to 2.50 13" 14" 16" 5.0 lbs.63-DP13 1.35 to 1.75 13" 14.5" 15" 8.25 lbs.63-DP15 1.75 to 2.00 15" 16.5" 15" 9.5 lbs.63-DP16 1.75 to 2.25 10.5" × 15" 13" × 17.5" 15" 16 lbs.63-DP20 2.25 to 3.00 12" × 19.5" 14.5" × 22" 16" 17 lbs.
OEM Replacements63-D20 Grimsby 97 - 77 10.5" × 10.5" 11.5" × 11.5" 12" 3 lbs.63-D21 Grimsby 117 - 77 10.5" × 10.5" 11.5" × 11.5" 12" 3 lbs.63-D22 Grimsby 140 - 79 12" × 12.25" 13" × 13.5" 13" 4.5 lbs.63-D23 Grimsby 158 - 79 11.75" × 11.88" 13" × 13.88" 12" 4.5 lbs.63-D24 Grimsby W - 196 9.125" × 9" 10.125" × 10" 10.25" 3 lbs.63-D30 Esso #110 5 Component Set 12 lbs.63-D31 Esso #150 5 Component Set 15 lbs.
Wet Pak Sheets
Part # G.P.HInside
DiameterDimensions Weight
63-1WETPAK 1.25
Flat Sheet Sizes
14" x 48" × 0.5" 9.0 lbs.
63-2WETPAK 2.501pc. 14" x 48"× 0.5" &1pc. 16" x 16"× 0.5"
10.0 lbs.
63-3WETPAK 2.651pc.16" x 48"× 0.5" &1pc. 16" × 16"× 0.5"
10.25 lbs.
alltemp heating special 08/09 15
2008/09 Heating Specialwww.alltemp.ca
Alltemp Humidifier Pads• Available for furnace or portable type.• Keep environment fresh and clean!• Increase efficiency and life of humidifier!
Furnace Type HumidifierPart # Make Model
70-3802-1• Carrier• Lau• Texaco
- LB18- VA2
70-3815-2S • Homart-Sears - 15
70-3817-2S • Lau - L17
70-3824-ISNC• Acquaduct• Essomatic• Metro-Vision
- 100555- 105- 240
70-3831-IS • Homart-Sears - 931
70-3840-ISN • Walton - WL-140
70-3841-ISN • Esso - Ultramatic 1624
70-3845-ISN• Montgomery-Ward• Wait-Skuttle
- 12- 45, 45S
70-3850-1 • Electrohome - FH450G
70-3867-ISN • General - 67
70-3897-ISN• Autoflo• Lennox
- 97- WD2-20Portable Type Humidifier
Part # Make Model70-3902-S • Electrohome - YH7S-301
70-3903-S • Wait-Skuttle - 1725-11
70-3906 • Air King - 64-07901-001
Humidifier Pads
70-3890-ISNIllustrated
70-3902-SIllustrated
Furnace Type Humidifier Pads
Portable Type Humidi-fier Pads
"OPAQUE"Hard Shell
Humidifier Tubing (Polyethylene)Part # OD. ID Length Working PSI
08-PT4X2X100
1/4"1/8"
100'
40008-PT4X2X1000 1000'08-PT4X.1701C
1/6"100'
08-PT4X.1702M 2000'08-PT5X3X100 5/16" 3/16" 100' 60008-PT6X4X100 3/8" 1/4" 100' 40008-PT8X6X100 1/2" 3/8" 100' 30008-PT10X8X100 5/8" 1/2" 100' 240
Larger rolls available.
Humidifier Tubing
Features• Hard shell.• Colour - opaque.
"CLEAR"Soft Shell
08-2501-100Illustrated
Drain Tubing (Poly-Vinyl)Part # ID OD Wall Length Max. PSI*
08-2506-100 3/16" 5/16" 1/16"
100'
5508-2500-100 1/4" 3/8" 1/16" 5508-2501-100 3/8" 1/2" 1/16" 4508-2515-100 3/8" 5/8" 1/8" 5508-2502-100 1/2" 5/8" 1/16" 3008-2503-100 5/8" 3/4" 1/16" 3008-2527-100 5/8" 7/8" 1/8" 4008-2505-SPEC 7/8" 1 1/8" 1/8" 3008-2503-SPEC 5/8" 13/16" 3/32" 3508-2508-SPEC 1" 1 1/4" 1/8" 2508-2504-50 3/4" 29/32" 5/64"
50'20
08-2505-50 7/8" 1 1/16" 3/32" 20* Max PSI @ 70°F / Operating Temperatures 70°F (Ideal) to 150°F (Max)
Drain Tubing
Alltemp Drain
Tubing
Will Not Kink!!!Features
• Soft shell.• Does not kink!• Colour - clear.• Individually boxed(c/w knock-out hole).
NOTE:Larger rolls or other
wall thicknesses avail-able upon request.
08-PT4X2X100 Illustrated
alltemp heating special 08/0916
2008/09 Heating Specialwww.alltemp.ca
Silicone
General Purpose Sealant / AdhesivesContractor grade sealants and adhesives are formulated for professional contrac-tor use only and are available in a variety of general purpose styles for increased convenience and efficiency. The long-term reliability under extremely environmental conditions make these general purpose silicone adhesives the ideal rubber sealant for any interior or exterior job.
SiliconePart # Description
83-SCS1000C Clear83-SCS1000W White83-SCS1000A Aluminum83-SCS1000B Black83-IS806 Red "Hi-Temp"
83-SCS1000 Application Temperature: -37°C to 60°C (-35°F to 140°F).
Performance Temperature: -62°C to 204°C (-80°F to 400°F).
83-IS806 Performance Temperature: -60°C to 260°C (-75°F to 500°F).
83-IS806Hi-Temp Silicone
Illustrated
83-SCS1000WIllustrated
Cartridge Type Smoke Emitters
Part # TypeBurning Time
(seconds)Cartridge /
PackSmoke Emitted
(Cu. ft.)Weight /
Cartridge61-S210 Splintax 20 20 matches/ pk 20 0.35 oz.61-HT102 Fumax 45 10 150 1/10 lbs61-HT103 Fumax KS 90 10 600 1/3 lbs61-HT104 Ventax 180 5 1,200 2/3 lbs61-HT105 Datax 240 5 2,500 2 lbs61-HT107 Brandax KS 480 1 18,000 1 lbs
Smoke Emitters61-HT102
Illustrated 61-HT105Illustrated
61-S210Illustrated
Pen Type Smoke EmitterPart # Description
61-S220Contains 1 pen with 6/ pk replacement wicks. 6 wicks provide up to 3 hours of continuous smoke, or 360 individual 30 second tests.
61-S221 6 pack of replacement wicks in plastic case for 61-S220 smoke pen.
Smoke BottlesPart # Description
61-S101 10 Smoke bottles. Each bottle can be used for 24 hours after ampule has been broken.
Note: The smoke generated by smoke bottles is corrosive.
61-S101Illustrated
Powder-PuffersPart # Description
61-S201 10 Powder-Puffers.
61-S201Illustrated
61-S220Illustrated
61-S221Illustrated
Crankcase Heaters
Self Regulating! "Compressor Burnout Protection!"• When a refrigeration compressor shuts down or enters a long-off
cycle, liquid refrigerant migrates into its crankcase oil. Lubrication decreases and crankcase burnout can occur when operation re-sumes.
• Energy efficient, self-regulating design automatically varies output to maintain adequate oil temperature while permitting wrapping and crossover without burnout.
• Handles compressors up to 5 Hp, 120 or 240 volt applications.• Fits all crankcases with circumferences smaller than 49".
Crankcase Compressor Heaters - FreezGard™
Part # VoltsOutput @-18°C (0°F)
Output @16°C (60°F)
Weight
75-CCH1 12060W 35W
0.5 lbs.75-CCH2 240 0.5 lbs.
Raychem
alltemp heating special 08/09 17
2008/09 Heating Specialwww.alltemp.ca
120V• Blue Cable - Steel Braid
Part # Watts/ft Power Length Weight75-H611050 6 120V 50' Box 3.0 lbs.75-H611100* 6 120V 100' Truck Pack 9.0 lbs.75-H611250 6 120V 250' Reel 17.0 lbs.
120V• Blue Cable - Steel Braid - Black Jacket
Part # Watts/ft Power Length Weight75-H612050 6 120V 50' Box 4.0 lbs.75-H612100* 6 120V 100' Truck Pack 10.0 lbs.75-H612250 6 120V 250' Reel 20.0 lbs.75-H612500 6 120V 500' Reel 43.0 lbs.75-H6121000 6 120V 1000' Reel 77.0 lbs.
240V• Red Cable - Steel Braid - Black Jacket
75-H622050 6 240V 50' Box 4.0 lbs.75-H622100* 6 240V 100' Truck Pack 10.0 lbs.75-H622250 6 240V 250' Reel 20.0 lbs.75-H622500 6 240V 500' Reel 43.0 lbs.75-H6221000 6 240V 1000' Reel 77.0 lbs.
* 100' Truck Packs include (2) 75-H900, (1) 75-H903 & (1) 75-H910.
240V• Red Cable - Steel Braid
75-H621050 6 240V 50' Box 3.0 lbs.75-H621100* 6 240V 100' Truck Pack 9.0 lbs.75-H621250 6 240V 250' Reel 17.0 lbs.
* 100' Truck Packs include (2) 75-H900, (1) 75-H903 & (1) 75-H910.
Self Regulating Heat Cable
Keep Wet Areas From FreezingWith WinterGard Wet for tracing air
conditioner drain pans to prevent freezing or gut tracing freezer drain lines to prevent
backup problems.
Protect PipesWith WinterGard or Winter-
Gard Plus for freeze protection of short & small diameter pip-ing. Pre-cut lengths or custom
cut lengths.
Applications- Ideal freeze protection for pipes in un-
heated attics, basements and garages.- Use it for intake and drain lines, water
meters, outside pipes and taps.
Applications- Ideal for residential & commercial build-
ings.- Use it to freeze protect water service &
fire protection systems.- Roof & gutter de-icing.
WinterGard Heating Cable• Economical solution for residential/ commercial pipes up
to 2" diameter and circuit length up to 250'.• Dry applications only. • Tough - steel braided.
WinterGard Plus Heating Cable• Designed for more demanding residential/ commercial
with larger plastic or metal pipes with diameters up to 8" and circuit lengths up to 250'.
• Dry applications only. • Tough - steel braided.
WinterGard Wet Heating Cable• The answer for freeze protection in wet or high moisture
residential/ commercial locations such as drain lines with larger plastic or metal pipes. Suitable for pipe diam-eters up to 8" and circuit lengths up to 1000'.
• Wet or dry applications. • Tough - steel braided & waterproof outer jacket.
"Self Regulating"Heating Tape
• Easy installation• Won’t burn out• Won’t overheat• OK to overlap• OK to insulate
• OK for plastic• No thermostat required• Cut to desired length• Higher efficiency• UL & CSA approved
****WinterGard Wet ***WinterGard Plus **WinterGard
18 AWG Bus Wires
Conductive Core
Tinned Copper Braid***
Insulating Jacket**
Waterproof Outer Jacket****
Raychem
alltemp heating special 08/0918
2008/09 Heating Specialwww.alltemp.ca
AccessoriesPart # Description Weight
75-H900 Power connection kit. 0.5 lbs.75-H903 Fibreglass application tape & "Electric traced" labels. 0.3 lbs.75-H908 Plug-in Power connection kit. 1.0 lbs.75-H910 Splice & tee kit. 0.3 lbs.75-FGK-P-RS "Original" termination kit. 0.3 lbs.75-H911* Plug-in power connection kit. 0.5 lbs.75-H912 Gel-filled end seal kit (2 ea.) 0.3 lbs.75-H913 Roof clips (10 ea.) 1.0 lbs.75-H914 Roof clips (50 ea.) 4.0 lbs.75-H915 Downspout hanger bracket. 0.5 lbs.75-H921 120V junction box with ELCI. 4.0 lbs.75-H931 Plug-in GFCI adapter. 1.0 lbs.75-AMC-F5 Fixed point thermostat 5°C (40°F). 1.5 lbs.
75-TC-32 receptacle thermo cube thermostatically controlled outlet (120V, 15 amp).- ON @ 2°C (35°F), OFF @7°C (45°F).
1.0 lbs.
*75-H911 connection kit is for use only with 75-H311 series heating cables. Plug includes GFI.
Self Regulating (Pre-assembled) Heat Cable
120VPart # Watts/ft Volts Length Weight
75-W51-6P 5 120V 6' Kit 1.0 lbs.75-W51-12P 5 120V 12' Kit 1.3 lbs.75-W51-18P 5 120V 18' Kit 1.6 lbs.75-W51-24P 5 120V 24' Kit 2.0 lbs.75-W51-50P 5 120V 50' Kit 3.3 lbs.75-W51-75P 5 120V 75' Kit 5.4 lbs.75-W51-100P 5 120V 100' Kit 6.9 lbs.
240V75-W52-6L 5 240V 6' Kit 1.0 lbs.75-W52-12L 5 240V 12' Kit 1.3 lbs.75-W52-18L 5 240V 18' Kit 1.6 lbs.75-W52-24L 5 240V 24' Kit 2.0 lbs.
Gardian Pre-assembled Heating Cable Kits• Perfect for residential or commercial small applications
with short pipe runs up to 100', 2" diameter. • Rugged copper braid provides abrasion and damage
protection.• 120V (30" power cord & plug) 240V (hardwired).
75-H611250250' Reel Illustrated
75-H61105050' Box Illustrated
75-H611100100' Truck Pack Illustrated
75-FGK-P-RSTermination Kit
Illustrated
75-W51-6PIllustrated
Gardian Pre-assembled
Heating Cable
Accessories - Self Regulating Heat Cable
Self Regulating Heat Cable - Continued
Standard Packaging• Winter Guard.• Winter Guard Plus.• Winter Guard Wet.
Raychem
Raychem
Raychem
alltemp heating special 08/09 19
2008/09 Heating Specialwww.alltemp.ca
Rubberized Cork Insulation Tape
Wraptite Rubberized Cork Insulation TapeFormulated to provide insulation and to prevent condensation on hot or cool pipes, fittings and tubing used in heating, air conditioning, refrigera-tion and plumbing applications. Cork Insulation Tape adheres well to most clean, dry surfaces and to itself, making it possible to apply more than one layer without adding fasteners or adhesives.
It is sufficiently soft and pliable enabling it to be molded around most fitting or connections. The material retains it's flexibility and adhesion after prolonged exposure to UV and over a service temperature range of -29°C to 88°C (-20°F to 190°F). Cork Insulation Tape is black in colour and has a grainy, rubber-like consistency which is non-toxic and non-asbestos.
84-PT-30Illustrated
Wraptite Foam Insulation TapeFoam Insulation Tape is designed to seal, insulate and isolate vibration in air conditioning and refrigeration applications. The soft, flexible, closed cell sponge tape with paper covered self-adhesive backing seals out air and moisture while reducing heat loss or transfer. Cold water pipes, valves, chilled water and refrigeration lines can be wrapped to prevent sweating or condensation while hot water pipes and pipe heaters can be wrapped to insulate against heat loss.
Easily applied by hand, Wraptie Foam Insulation Tape adheres well to most clean, dry surfaces and to itself, making it possible to apply more than one layer. The formulated operating temperature of Wraptite Foam Insulation Tape is between -34°C to 82°C (-30°F to 180°F) with the ability to intermittently tolerate temperature of 98°C (210°F).
84-FT-30Illustrated
Wraptite Slugs & CordsSealing slugs & cord are soft, permanently pliable, water-resistant seal-ants having a wide variety of applications. The product has the unique quality of retaining the same consistency throughout its application range of -7°C to 60°C (20°F to 140°F). Non-asbestos and non-hardening, remains flexible to -7°C (-20°F).
Sealing slugs & cords are used widely in the air conditioning and refrig-eration industries to seal around outer cases, behind hinges and under breaker strips. They can be used to seal out air or moisture around utility panels, cables, ducts, window frames and metal joints. This product adheres to metal, wood, glass, plastic and most clean surfaces to provide an effective barrier against water, moisture, dirt and dust. It is non-stain-ing, non-bleeding, odorless and can be painted.
84-PS-30Illustrated
84-PC-30Illustrated
Foam Insulation Tape
Slugs & Cords
Wraptite's Standard Packaging
Includes, directions, bar-coding and complete product
line descriptions both in French & English.
Cork TapePart # Description
84-PT-30 1/8" × 2" × 30' Roll
Foam TapePart # Description
84-FT-30 1/8" × 2" × 30' Roll
Slugs & CordsPart # Description
84-PC-30 3/8" × 25' Cord84-PS-30 2 lb. Slug84-PS30-B 50 lb. Bulk Slug
alltemp heating special 08/0920
2008/09 Heating Specialwww.alltemp.ca
ATPH071008
ROTOM®, R-LINE®, HOTEMP® are registered trade marks of ALLTEMP® PRODUCTS COMPANY LIMITED. ALLTEMP® has made an effort to illustrate with photos, outline drawings and/or descriptions, the products in this catalogue. These are for the sole purpose of identification. We do not express or imply that products conform exactly to the descriptions, drawings and/or photos. All reasonable effort has been made to accurately determine a suitable product. However, all users are solely responsible to evaluate and determine for themselves the suitability of the product purchased for the use intended. All information, data and dimension tables in this catalogue have been carefully compiled and thoroughly checked. However, no responsibility for possible errors or omissions can be assumed. The company reserves the right to change specifications and other information included in this catalogue without notice. The vendor’s responsibility shall be limited only to its written warranty and the vendor shall not be responsible for any loss, cost or damage whatsoever from the use of this product by you or your customers.
Reduce Inventory!ATP thermostat guards come complete
with hardware, ring and solid bases.
Plastic Thermostat Guards
Features• Hi-impact plastic guards.• Horizontal and vertical mounting.• Heavy duty lock and key.• Comes with complete mounting hardware.• Each model includes a ring & solid base.• Colour - clear cover with off white base.
77-PG3Illustrated
Metal Thermostat Guards
Part # BaseInside Dimensions
Cross ReferenceL W D
77-MG3Ring 5.31" 4.31" 3.00" BTG-KWM KMRT
Solid 5.62" 5.12" 2.87" BTG-KM KMST
77-MG6Ring 6.31" 3.62" 3.18" BTG-EM EMST
Solid 6.62" 4.12" 3.75"BTG-RMBTG-RWM
RMRT
77-MG9Ring 6.75" 4.50" 3.43" BTG-UWM UMRT
Solid 7.18" 5.25" 3.43" BTG-UM UMST
77-MG12R* Ring 6.12" 3.81" 3.12" BTG-54VLW F29-0256
77-MG12S* Solid 6.37" 4.25" 3.00" BTG-54VL F29-0255
* Hinged metal guards do not come with both bases.
Metal Thermostat Guards
Features• Durable metal guards.• Horizontal and vertical mounting.• Heavy duty lock and key.• Comes with complete mounting hardware.• Each model includes a ring & solid base.*• Colour - off white cover with off white base.
77-PG9Illustrated
77-PG6Illustrated
Reduce Inventory!ATP thermostat guards come complete
with hardware, ring and solid bases.
Mounting Base Types77-MG3 Plastic77-MG6 Plastic77-MG9 Metal77-MG12R Metal77-MG12S Metal
Mounting Base TypesAll mounting bases are
plastic.
Plastic Thermostat Guards
Part # BaseInside Dimensions
Cross ReferenceL W D
77-PG3Ring 3.75" 3.50" 2.62" BTG-EK F29-0252
Solid 4.00" 4.00" 2.50" ECST029-0178029-0179
77-PG6Ring 5.25" 4.62" 3.12" BTG-K F29-0251
Solid 5.75" 5.00" 2.81" KCBT F29-0257
77-PG9Ring 6.31" 3.62" 3.06" BTG-RK F29-0253
Solid 6.62" 4.12" 2.75" RCBT 029-0143
77-PG12Ring 8.18" 4.62" 3.56" BTG-UK F29-0254
Solid 8.50" 5.00" 3.87" UCBT 029-0198
77-MG3Illustrated
77-MG6Illustrated
77-MG9Illustrated
77-MG12R - HingedIllustrated
77-PG12Illustrated