commercial air conditioners -...

22
MCAC-2012-36 COMMERCIAL AIR CONDITIONERS 2012 Commercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: West region of Midea commercial air conditioner department, Industry Avenue, Beijiao, Shunde, Foshan, Guangdong, P.R. China Postal code:528311 Tel: +86-757-22394101 Fax: +86-757-26338003 http://www.midea.com http://www.mideaaircon.com Centrifugal Chiller

Upload: dangkhue

Post on 17-Apr-2018

235 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

MCAC-2012-36

COMMERCIAL AIR CONDITIONERS

2012

Commercial Air Conditioner Business UnitsMidea Air Conditioning and Refrigeration SectorAdd: West region of Midea commercial air conditioner department, Industry Avenue, Beijiao, Shunde, Foshan, Guangdong, P.R. China Postal code:528311Tel: +86-757-22394101 Fax: +86-757-26338003http://www.midea.com http://www.mideaaircon.com

Centrifugal Chiller

Page 2: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

Corporate Introduction

From its humble beginnings in 1968, Midea has developed into a large corporation, covering HVAC, appliances, lighting, industrial components, logistics, and real estate. Its 40 years of relentless growth has brought its global turnover to $14 billion USD in 2009. Consequently, Midea has created over 150,000 jobs both within China and all over the world. In addition to providing affordable goods to consumers worldwide, Midea is a responsible corporate citizen, and has contributed to several social causes. Midea believes in creating value through rapid response to market demands, cost-efficient operations and consumer satisfaction. As a result, Midea wields vast production capacities to meet these demands, a fully integrated manufacturing process, and a comprehensive range of affordable, high-quality products to serve its global customers.

Today, Midea is a home appliance leader in China. The company continues to actively globalize its operation by opening plants in Vietnam, Belarus and Egypt. Additionally, Midea has several forthcoming plants in order to offer enhanced products and services closer to the market.

Midea Group

Midea CAC (MCAC)As a key part of Midea Group, the Midea Central Air Conditioner (CAC) Business Unit is a professional CAC products supplier and commercial products solution expert. Since 1999 Midea central air-conditioner contributes to the commercial product R&D and technology innovation. By cooperating with the international enterprises plus the independent R&D, Midea CAC achieves big success in the commercial air-conditioner market and has established thousands of sample projects all over the world.

Right now Midea CAC is one of the most professional CAC products supplier as well as the professional project solution provider in marketing, sales, project design and after service etc.

MCAC Chongqing factory with 14 product lines concentrates on the water cooled centrifugal / screw/ scroll chillers, Air cooled screw/ scroll chillers, AHU/FCU etc.MCAC Shunde factory with 31 product lines concentrates on the VRF (DC inverter product/ Digital scroll product), split product, heat pump water heater, AHU/FCU etc.

Page 3: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

04Centrifugal Chiller07 Centrifugal Chiller

CONTENTS

MIDEA CHILLER MANUFACTURING-BASE INTRODUCTION

With 46 years experience in chiller industry, Midea Chongqing chiller manufacturing base is becoming one of the largest chiller company in China. It covers an area of 800 Mu (137 acre), with a registered capital of 12.5 million US $ and a total investment of over 0.6 billion US$. There are 6 product series and over 100 model products including centrifugal chiller, screw water chiller, scroll water chiller, water-cooled packaged unit, and central air-conditioning indoor terminal device(AHU/FCU). Five chiller manufacturing shops with 14 flexible production lines lead an anual manufacturing capacity of 250 units centrifugal chiller, 1000 units of air cooled screw chiller, 2000 units of water cooled screw chiller and 200000 units of AHU product.

Strong R&D and manufacturing capacity makes Midea Chongqing general become the fastest developing company in chiller industry. The chiller test lab which is certified by China National Refrigeration Equipment Inspection Center is the largest refrigeration test capacity in Asia. The engineer team with 100 top engineers and 2 chiller experts who were awarded by the central government in structure, electricity, performance testing and software aspect makes Midea the headship in chiller industry. In the year of 2011 Midea refrigeration group invests another 150 million RMB for test lab as ARI test floor, big capacity air cooled screw life span testing room, 1500kW compressor motor test floor, etc.

Concentrating on energy-saving and ejection-decreasing, Midea Chongqing chiller factory commits itself to the reliable and high efficiency products for the world. The chiller products are widely used in different countries and obtain good public praise from the clients. The solutions for the Beijing capital international airport ,Jakarta international airport, China rapid transit station won good feedback and commendation. Continuing with the past and opening up the future, Midea chiller brand will go further and create an illustrious future.

05

06

09

14

16

24

25

30

35

Nomenclature

Features and benefits

Specification

Performance curve

Dimension

Refrigeration cycle

Microprocessor control

Typical wiring diagram

Mechanical specification

Page 4: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

06Centrifugal Chiller05 Centrifugal Chiller

NOMENCLATURE

Centrifuge seriesS- dual stagesNone- single stage

Cooling capacity,RT

R134a centrifugal chiller

Product series code

Power Supply10-10kV None-380V

LC 1 500 M S 10

FEATURES AND BENEFITS

Near half a century of experience in design and manufacture of the chiller product enable Midea Company continues deliver products of high quality, high reliability and high efficiency to our customers all over the world. Midea independent designed second generation “Smart Star” centrifugal chiller use environment friendly R134a refrigerant which is not subject to scheduled phase out. And it has been proven can achieve high efficiency without compromising the environment and the effects of direct and indirect global warming potential are dramatically diminished. Environment Friendly R134aEnvironment and its sustainability is the responsibility of any company who can supply excellent products and service to the customers .Midea has long been committed to the environment and its sustainability, the Midea “Smart Star” centrifugal chiller provide our customers with a non-ozone depleting R134a refrigerant that can achieve high-efficiency, Chlorine-free, long-term solution without subject to refrigerant phase out. At the same time, R-134a chillers operate with the entire system above atmospheric pressure at all times, no need purge unit. In the event of a small leakage, refrigerant escapes from the chiller to the atmosphere, that allows easy detection and repair. And R134a features lowest toxicity and flammability rating which translate into lowest hazard.

High ReliabilitySingle-stage Semi-hermetic positive pressure compressor utilizes advanced international leading NREC design technology. Single-stage design eliminate the additional moving part in the multi-stage compressor, such as second impeller, this feature increased the reliability. The refrigerant cooled hermetic motor sealed from the external air and environment that greatly eliminates the contaminant possibility. Combine with shell-tube type heat exchangers designed,manufactured and tested according to the national standard of China. These practice ensure Midea centrifugal chiller achieve high reliability.

Semi-hermetic MotorThe motors are hermetically sealed from the machineroom, cooling is accomplished by spraying liquid refrigerant on the motor windings and shaft. This highly efficient cooling method results in the use of smaller, cooler-running motors. As a result, hermetic motors require lower inrush current and are smaller,lighter and quieter than comparable air-cooled motors.

Modular Construction The evaporator, condenser, and compressor assemblies are completely bolted together, making the chillers easy to disassembly and reassembly at the jobsite. This feature makes the chiller easy for transportation and lessen access problem in the jobsite. This attribute can mean considerable installation cost savings on many retrofit applications that may have limited doorway size.

Page 5: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

08Centrifugal Chiller07 Centrifugal Chiller

High Efficiency Fully-shrouded ImpellerFully-shrouded impeller features high strength aluminum-alloy backward curved vanes, refrigerant gas flows through the internal impeller passages without hydraulic interaction with the stationary casing walls. The impeller is designed for balanced thrust and is dynamically balanced and over speed tested.

Keyless Impeller CouplingThe impeller and the main shaft are coupled by keyless connection, it eliminates stress concentration on the power transmission surface and thus the life span of the impeller is greatly increased. Since there is no friction, the efficiency is higher than the traditional key coupling. This unmatched mechanical design was awarded by the State Intellectual Property Office of P.R.China. (Patent No.ZL 01 2 56825.2)

Precise GearingThe specially engineered, single helical gear with crowned teeth keep more than one tooth in contact at all times to provide even distribution of compressor load and quiet operation. Gear tooth surfaces are case hardened and precision ground which can reach the class of 5. Gears are integrally assembled in the compressor rotor support and are oil film lubricated. Each gear is individually mounted in its own journal and thrust bearings to isolate it from impeller and motor forces. The double layer soundproof compressor design prevents the gear contacting noise.

Lower Sound Levels and VibrationSpecial engineered gearing, double soundproof gearbox structure, optimized impeller and tunnel design ensure our chiller achieve lower sound levels. A gear-driven compressor runs at higher impeller rotational speeds but tends to have less vibration than the larger, much heavier, direct drive units.

Advanced Capacity Adjustment Inlet guide vanes work together with moveable diffuser lead to stepless capacity range from 10% to 100% and free of surge. This is why Midea centrifugal chiller can achieve high part load efficiency. And this technology was awarded by the State Intellectual Property Office of P.R.China. (Patent No.ZL01 2 56824.4).

Condenser BaffleThe baffle prevents direct impingement of high velocity compressor gas onto the condenser tubes. That eliminates the related vibration and wears of the tubes and distributes the refrigerant flow evenly over the length of the vessel for improved efficiency.

Reliable Lubricant SystemThe lubrication system consists of an internal oil sump with oil heaters, positive displacement oil pump, brazed plate oil cooler, and oil return line. High position oil sump supply oil to the gear surface for lubrication, prevent the gear from burnt if sudden power loss happens.

External Oil Filter and Oil coolerA plate type oil cooler is factory mounted aside the compressor. An external oil filter and oil cooler is easy to do maintenance and replacement. Change of the oil filter or oil cooler can be done after closed the isolation valve in the pipe line.

Unmatched Oil Reclaim SystemDuring the running of chiller unit, a small amount of lube may interfuses into the refrigerant. Midea patented oil reclaim system designed to return the oil from the heat exchanger back to the oil tank. It will improve the refrigerant purity to increase the thermal exchange efficiency and provide sufficient oil to compressor.

Low Inrush Current Standard starter for Midea centrifugal chiller is a popular type for centrifugal chiller applications, that’s wye-delta starter. The motor windings first connect in a “wye” configuration to reduce the inrush current to 33.3% of locked rotor amps and producing 33.3% of normal starting torque. After a brief delay (transition time), the electrical load is momentarily transitioned to resistances while the motor windings are changed to the “delta” configuration. The resistances minimize the second inrush current when the delta configuration becomes active.

100% Factory Run-TestedIn Midea factory, after assembled, the unit will 100% go through performance test in the test center. The benefits of a performance test include verification of performance, prevention of operational problems and assurance of a smooth start-up. A chiller that has been tested is operation and performance-proven.

Page 6: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

10Centrifugal Chiller09 Centrifugal Chiller

SPECIFICATION

Notes:1. Nominal Cooling capacities are based on following conditions:

Chilled water inlet/outlet temperature 12°C/7°C(53.6°F/44.6°F);Cooling water inlet/outlet temperature 32°C/37°C(89.6°F/98.6°F).

2. The design fouling factor for both evaporator and condenser are 0.086m2 ·°C/kW (0.0005ft2 ·°F·hr/Btu),otherwise can be customized.

3. The design working pressure for both evaporator and condenser are 1.0MPa, higher pressure demand can be customized.

550

1934

166

332

78

500

1758

151

302

80

450

1582

136

272

82

400

1406

120

242

85

350

1230

105

210

80

DN200

256

88

DN200

292

88

DN200

327

89

DN200

362

90

DN250

397

85

DN200

230

300

DN200

262

300

DN200

293

385

DN200

313

385

DN250

345

385

424

1199

\

\

0.657

7205

8279

400

4671

1850

2054

0.655

7325

8438

500

4671

1850

2054

0.651

7510

8702

500

4671

1850

2054

0.626

7630

8938

500

4671

1850

2054

0.627

8365

9795

550

4725

1990

2162

484

1199

\

\

541

1538

\

\

578

1538

\

\

637

1538

\

\

Chilled water flow volume

Chilled water pressure drop

Pass

Fouling factor

Water side design pressure

Chilled water inlet/outlettemperature

Water pipe inlet/outlet diameter

Cooling water flow volume

Cooling water pressure drop

Pass

Fouling factor

Water side design pressure

Cooling water inlet/outlettemperature

Water pipe inlet/outlet diameter

Running power

Configured power

Power supply

Rated Current(380V)

Starting Current (380V)

Rated Current(10000V)

Starting Current(10000V)

Motor rotate speed

Motor cooled by

Shipping weight

Running weight

R134a Charge

Length

Width

Height

LC350M LC400M LC450M LC500M LC550M

Coolingcapacity

Evaporator

Condenser

Compressor

Efficiency

Weight

Dimension

Refrigerant

2960

380–3-50

RT

kW

104kcal/h

Item Model

2

0.086

1.0

12/7

2

0.086

1.0

32/37

m3/h

kPa

m2 ·°C/kW

Mpa

°C

m3/h

kPa

m2·°C/kW

Mpa

°C

kW

kW

V-Ph-Hz

A

A

A

A

RPM

kW/RT

kg

kg

kg

mm

mm

mm

Notes:1. Nominal Cooling capacities are based on following conditions:

Chilled water inlet/outlet temperature 12°C/7°C(53.6°F/44.6°F);Cooling water inlet/outlet temperature 32°C/37°C(89.6°F/98.6°F).

2.The design fouling factor for both evaporator and condenser are 0.086m2 ·°C/kW (0.0005ft2 ·°F·hr/Btu),otherwise can be customized.

3. The design working pressure for both evaporator and condenser are 1.0MPa, higher pressure demand can be customized.

800

2814

242

484

90

750

2637

226

452

92

700

2461

211

422

86

650

2285

196

392

90

600

2110

181

362

82

DN250

433

88

DN250

466

92

DN250

501

93

DN250

537

92

DN300

575

89

DN250

376

445

DN250

406

490

DN250

437

490

DN250

470

560

DN300

500

560

694

1778

\

\

0.627

8550

10046

550

4725

1990

2162

0.625

10890

12206

660

5077

2200

2540

0.624

10940

12399

680

5077

2200

2540

0.627

11170

12786

680

5077

2200

2540

0.625

11325

13020

740

5077

2300

2540

741

1947

29

256

798

1947

31

256

858

2225

33

292

913

2225

35

292

Chilled water flow volume

Chilled water pressure drop

Pass

Fouling factor

Water side design pressure

Chilled water inlet/outlettemperature

Water pipe inlet/outlet diameter

Cooling water flow volume

Cooling water pressure drop

Pass

Fouling factor

Water side design pressure

Cooling water inlet/outlettemperature

Water pipe inlet/outlet diameter

Running power

Configured power

Power supply

Rated Current(380V)

Starting Current (380V)

Rated Current(10000V)

Starting Current(10000V)

Motor rotate speed

Motor cooled by

Shipping weight

Running weight

R134a Charge

Length

Width

Height

m3/h

kPa

m2 ·°C/kW

Mpa

°C

m3/h

kPa

m2 ·°C/kW

Mpa

°C

kW

kW

V-Ph-Hz

A

A

A

A

RPM

kW/RT

kg

kg

kg

mm

mm

mm

LC600M LC650M LC700M LC750M LC800M

Coolingcapacity

Evaporator

Condenser

Compressor

Efficiency

Weight

Dimension

Refrigerant

2960

380/6000/10000–3-50380–3-50

RT

kW

104kcal/h

Item Model

2

0.086

1.0

12/7

2

0.086

1.0

32/37

Page 7: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

12Centrifugal Chiller11 Centrifugal Chiller

Notes:1. Nominal Cooling capacities are based on following conditions:

Chilled water inlet/outlet temperature 12°C/7°C(53.6°F/44.6°F);Cooling water inlet/outlet temperature 32°C/37°C(89.6°F/98.6°F).

2.The design fouling factor for both evaporator and condenser are 0.086m2 ·°C/kW (0.0005ft2 ·°F·hr/Btu),otherwise can be customized.

3. The design working pressure for both evaporator and condenser are 1.0MPa, higher pressure demand can be customized.

1100

3867

332

664

92

1000

3510

302

604

88

950

3340

287

574

92

900

3165

272

544

92

850

2988

257

514

88

DN300

611

95

DN300

645

92

DN300

680

88

DN300

719

92

DN300

789

91

DN300

532

630

DN300

563

630

DN300

595

695

DN300

623

695

DN350

679

760

966

2503

38

329

0.626

11685

13681

790

5077

2300

2540

0.626

11830

13868

790

5077

2300

2540

0.626

14160

16532

820

5160

2500

2625

0.623

14330

16652

820

5160

2500

2625

0.617

14480

16832

900

5160

2500

2625

1022

2503

40

329

1081

2761

42

363

1131

2761

44

363

1233

3020

48

378

Chilled water flow volume

Chilled water pressure drop

Pass

Fouling factor

Water side design pressure

Chilled water inlet/outlettemperature

Water pipe inlet/outlet diameter

Cooling water flow volume

Cooling water pressure drop

Pass

Fouling factor

Water side design pressure

Cooling water inlet/outlettemperature

Water pipe inlet/outlet diameter

Running power

Configured power

Power supply

Rated Current(380V)

Starting Current (380V)

Rated Current(10000V)

Starting Current(10000V)

Motor rotate speed

Motor cooled by

Shipping weight

Running weight

R134a Charge

Length

Width

Height

LC850M LC900M LC950M LC1000M LC1100M

Coolingcapacity

Evaporator

Condenser

Compressor

Efficiency

Weight

Dimension

Refrigerant

2960

380/6000/10000–3-50

RT

kW

104kcal/h

Item Model

2

0.086

1.0

12/7

2

0.086

1.0

32/37

m3/h

kPa

m2 ·℃/kW

Mpa

m3/h

kPa

m2 ·℃/kW

Mpa

kW

kW

V-Ph-Hz

A

A

A

A

RPM

kW/RT

kg

kg

mm

mm

mm

Notes:1. Nominal Cooling capacities are based on following conditions:

Chilled water inlet/outlet temperature 12°C/7°C(53.6°F/44.6°F);Cooling water inlet/outlet temperature 32°C/37°C(89.6°F/98.6°F).

2.The design fouling factor for both evaporator and condenser are 0.086m2 ·°C/kW (0.0005ft2 ·°F·hr/Btu),otherwise can be customized.

3. The design working pressure for both evaporator and condenser are 1.0MPa, higher pressure demand can be customized.

1500

5276

454

907

120

1600

5627

484

968

118

1700

5978

514

1028

120

1400

4924

423

847

115

1300

4572

393

786

102

1200

4220

363

726

95

DN300

862

96

DN350

926

94

DN350

992

105

DN350

1063

108

DN400

1135

115

DN400

1204

112

DN350

750

840

DN350

815

840

DN350

870

990

DN350

930

990

DN400

990

1100

DN400

1050

1100

1362

3337

53

418

0.625

14600

17480

1050

5160

2500

2625

0.627

16180

18250

1260

5189

2700

2780

0.621

17737

20203

1310

5540

2700

2880

0.620

18189

20424

1400

5540

2700

2880

0.619

19218

22363

1420

5540

2700

2880

0.618

19453

23485

1470

5590

2880

3030

1456

3337

57

418

\

\

61

466

\

\

65

466

\

\

69

518

\

\

72

518

Chilled water flow volume

Chilled water pressure drop

Pass

Fouling factor

Water side design pressure

Chilled water inlet/outlettemperature

Water pipe inlet/outlet diameter

Cooling water flow volume

Cooling water pressure drop

Pass

Fouling factor

Water side design pressure

Cooling water inlet/outlettemperature

Water pipe inlet/outlet diameter

Running power

Configured power

Power supply

Rated Current(380V)

Starting Current (380V)

Rated Current(10000V)

Starting Current(10000V)

Motor rotate speed

Motor cooled by

Shipping weight

Running weight

R134a Charge

Length

Width

Height

m3/h

kPa

m2 ·℃/kW

Mpa

m3/h

kPa

m2 ·℃/kW

Mpa

kW

kW

V-Ph-Hz

A

A

A

A

RPM

kW/RT

kg

kg

kg

mm

mm

mm

LC1200M LC1300M LC1400M LC1500M LC1600M LC1700M

Coolingcapacity

Evaporator

Condenser

Compressor

Efficiency

Weight

Dimension

Refrigerant

2960

6000/10000–3-50 6000/10000–3-50380/6000/10000–3-50

RT

kW

104kcal/h

Item Model

2

0.086

1.0

12/7

2

0.086

1.0

32/37

Page 8: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

14Centrifugal Chiller13 Centrifugal Chiller

Notes:1. Nominal Cooling capacities are based on following conditions:

Chilled water inlet/outlet temperature 12°C/7°C(53.6°F/44.6°F);Cooling water inlet/outlet temperature 32°C/37°C(89.6°F/98.6°F).

2.The design fouling factor for both evaporator and condenser are 0.086m2 ·°C/kW (0.0005ft2 ·°F·hr/Btu),otherwise can be customized.

3. The design working pressure for both evaporator and condenser are 1.0MPa, higher pressure demand can be customized.

1650

5800

500

998

106

1800

6330

545

1089

108

1900

6680

575

1150

108

2000

7030

605

1210

110

1500

5275

455

907

105

1350

4745

410

816

105

1200

4220

365

726

102

DN350

853

98

DN350

959

104

DN350

1066

104

DN400

1172

103

DN400

1279

114

DN400

1350

107

DN400

1421

110

DN350

740

840

52

383

58

399

64

427

71

471

77

515

82

542

86

568

DN350

830

875

DN350

922

970

DN400

1014

1070

DN400

1108

1170

DN400

1168

1230

DN400

1228

1290

0.617

22160

23250

1100

5460

2600

2780

0.615

23050

25100

1200

5540

2900

3000

0.615

23500

25750

1500

5540

2900

3000

0.615

24100

26150

1751

5540

2900

3000

0.616

27050

28800

1905

5780

3150

3140

0.615

27320

29400

1920

5780

3150

3140

0.614

27600

29800

1960

5780

3150

3140

Chilled water flow volume

Chilled water pressure drop

Pass

Fouling factor

Water side design pressure

Chilled water inlet/outlettemperature

Water pipe inlet/outlet diameter

Cooling water flow volume

Cooling water pressure drop

Pass

Fouling factor

Water side design pressure

Cooling water inlet/outlettemperature

Water pipe inlet/outlet diameter

Running power

Configured power

Power supply

Rated Current(10000V)

Starting Current(10000V)

Motor rotate speed

Motor cooled by

Shipping weight

Running weight

R134a Charge

Length

Width

Height

m3/h

kPa

m2 ·℃/kW

Mpa

m3/h

kPa

m2 ·℃/kW

Mpa

kW

kW

V-Ph-Hz

A

A

RPM

kW/RT

kg

kg

kg

mm

mm

mm

LC1200MS LC1350MS LC1500MS LC1650MS LC1800MS LC1900MS LC2000MS

Coolingcapacity

Evaporator

Condenser

Compressor

Efficiency

Weight

Dimension

Refrigerant

2960

10000–3-50

RT

kW

104kcal/h

Item Model

2

0.086

1.0

12/7

2

0.086

1.0

32/37

PERFORMANCE CURVE

40

50

60

70

80

90

100

110

120

130

140

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40CET (°C)

ELT(°C) 5°C 6°C 7°C 8°C 9°C

40

50

60

70

80

90

100

110

120

130

140

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39

ELT(°C) 5°C 6°C 7°C

8°C 9°C

CET (°C)

LC350M~LC600M Cooling Capacity Percentage (%)

LC650M~LC1300M Cooling Capacity Percentage (%)

Note: CET=condenser entering temperature, ELT=evaporator leaving temperature.

Note: CET=condenser entering temperature, ELT=evaporator leaving temperature.

Page 9: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

16Centrifugal Chiller15 Centrifugal Chiller

LC1400M~LC1700M Cooling Capacity Percentage( %)

CET (°C)

CET (°C)

LC1200MS~LC2000MS Cooling Capacity Percentage( %)

Note: CET=condenser entering temperature, ELT=evaporator leaving temperature.

Note: CET=condenser entering temperature, ELT=evaporator leaving temperature.

140

130

120

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38

110

100

90

80

70

60

50

140

130

120

110

100

90

80

70

60

50

40

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38

ELT(°C) 5°C

6°C 7°C 8°C 9°C

ELT(°C) 5°C6°C

7°C8°C

9°C

DIMENSION

T

mm

3780

3780

3780

S

mm

400

400

400

Q

mm

350

350

350

R

mm

200

200

200

P

mm

240

240

240

N

mm

200

200

200

E

mm

670

670

720

G

mm

780

780

870

M

mm

2150

2150

2290

C

mm

2019

2019

2127

B

mm

1850

1850

1990

A

mm

4673

4673

4730

Model

LC350M

LC400M

LC450M

LC500M

LC550M

LC600M

Dimension Unit Base

Evaporator

Diameter

DN200

DN200

DN250

Condenser

Diameter

DN200

DN200

DN250

J

mm

925

925

995

H

mm

1020

1020

1035

I

mm

650

650

635

K

mm

490

490

535

L

mm

820

820

890

F

mm

410

410

460

Model

LC350M

LC400M

LC450M

LC500M

LC550M

LC600M

Pipe Locate Position

LC350M-LC600M

Page 10: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

18Centrifugal Chiller17 Centrifugal Chiller

A

mm

5077

5077

5160

5160

5189

5540

55405590

B

mm

2250

2300

2500

2500

2700

2700

27002880

C

mm

2540

2540

2625

2625

2780

2880

28803030

M

mm

2500

2600

2800

2800

3040

3040

30403220

G

mm

1000

1000

1100

1100

1100

1150

11501240

E

mm

800

900

1000

1000

1000

950

9501040

N

mm

200

200

200

200

300

300

300300

P

mm

240

240

240

240

300

300

300300

R

mm

200

200

200

200

300

300

300300

Q

mm

350

350

350

350

450

450

450450

S

mm

400

400

400

400

600

600

600600

U

mm

80

80

80

80

100

120

120120

T

mm

4080

4080

4080

4080

4040

4340

43404340

Model

LC650MLC700MLC750MLC800MLC850MLC900MLC950MLC1000MLC1100MLC1200MLC1300MLC1400MLC1500MLC1600MLC1700M

Dimension Unit Base

F

mm

550

550

560

560

605

580

580665

L

mm

1050

1050

1110

1110

1155

1280

12801365

K

mm

600

600

650

650

700

725

725770

I

mm

735

785

885

885

930

930

915945

H

mm

1205

1255

1425

1425

1480

1480

14951565

J

mm

1100

1150

1250

1250

1350

1350

13501440

Evaporator

Diameter

DN250

DN300

DN300

DN300

DN350

DN350

DN400DN400

Condenser

Diameter

DN250

DN300

DN300

DN350

DN350

DN350

DN400DN400

Model

LC650MLC700MLC750MLC800MLC850MLC900MLC950MLC1000MLC1100MLC1200MLC1300MLC1400MLC1500MLC1600MLC1700M

Pipe Locate Position

LC650M-LC1700M

U

mm

100

100

100

100

100

100

100

T

mm

4340

4340

4340

4340

4540

4540

4540

S

mm

600

600

600

600

600

600

600

Q

mm

450

450

450

450

450

450

450

R

mm

300

300

300

300

300

300

300

P

mm

280

280

280

280

280

280

280

N

mm

300

300

300

300

300

300

300

E

mm

1050

1050

1050

1050

1170

1170

1170

G

mm

1150

1250

1250

1250

1380

1380

1380

M

mm

2700

3200

3200

3200

3450

3450

3450

C

mm

2780

3000

3000

3000

3140

3140

3140

B

mm

2600

2900

2900

2900

3150

3150

3150

A

mm

5460

5540

5540

5540

5790

5790

5790

Model

LC1200MS

LC1350MS

LC1500MS

LC1650MS

LC1800MS

LC1900MS

LC2000MS

Dimension Unit Base

Evaporator

Diameter

DN350

DN350

DN350

DN400

DN400

DN400

DN400

Condenser

Diameter

DN350

DN350

DN350

DN400

DN400

DN400

DN400

J

mm

1300

1450

1450

1450

1585

1585

1585

H

mm

675

775

775

775

840

840

840

I

mm

1195

1360

1360

1375

1410

1410

1410

K

mm

655

810

810

795

790

790

790

L

mm

1155

1325

1325

1325

1440

1440

1440

F

mm

605

625

625

625

740

740

740

Model

LC1200MS

LC1350MS

LC1500MS

LC1650MS

LC1800MS

LC1900MS

LC2000MS

Pipe Locate Position

LC1200MS-LC2000MSA

KJB

FL

IH

C

Cond. water outlet

Cond. water inlet

Evap. water outlet

Evap. water inlet

U

T

RP

P

Q

EN

G

S

A

A

B

M

550200

45°

450

80 100

P

100

B - B

A - A

BCenterline of Condenser

Centerline of Evaporator

Steel Base ¦∆20xPxSRubber Pad ¦∆15xPxR

Base of Unit

Rubber Pad ¦∆15xPxR

Steel Base ¦∆20xPxR

Foundation Bolt M30x500

Nut M30

Drainage Line

Filled with Concrete

Washer Ф 30

Page 11: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

20Centrifugal Chiller19 Centrifugal Chiller

CONSTRUCTIONLC350M- LC600M

1. Condenser Security Valve2. Evaporator Security Valve3. Compressor 4. Motor5. Lifting Points6. Evaporator7. Oil Level Sight Glass8. Refrigerant Charge valve9. Refrigerant Level Sight Glass

10. Air Release Valve11. Oil Pump12. Guide Vane Actuator13. Condenser14. Oil Reclaim Device15. Oil Cooler16. Oil Pump Starter 17. Water Drainage Valve

Front View

Rear View

LC650M- LC1700M

Front View

Rear View

1. Motor 2. Air Release Valve 3. Water Drainage Valve 4. Oil Filter5. Oil pump 6. Oil Cooler7. Oil Level Sight Glass8. Refrigerant Charge valve9. Evaporator 10. Control Panel11. Refrigerant Level Sight Glass

12. Evaporator Security Valve 13. Compressor 14. Guide Vane Actuator 15. Lifting Points16. Condenser Security Valve 17. Oil Reclaim Device18. Liquid Line Butterfly Valve (Optional)19. Condenser20. Discharge Line Butterfly Valve (Optional)21. Oil Pump Starter

Page 12: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

22Centrifugal Chiller21 Centrifugal Chiller

LC1200MS-LC2000MS

Front View

Rear View

1. Water outlet/inlet temperature sensor2. Security Valve3. Guide Vane Actuator4. Compressor5. Oil level Sight Glass6. Motor7. Air Release Valve

1 3

11 12

4 5 6

8

14

9

13

10 7

2

8. Water Drainage Valve9. Evaporator10. Control Panel11. Motor Connection Box12. Economizer13. Condenser 14. Electric Valve

SERVICE SPACE

Model

LC350M~LC600M

LC650M~LC1300M

LC1400M~LC1700M

LC1200MS~LC2000MS

M

1100

1500

1500

1500

T

4200

4500

5300

5300

Y

1200

1300

1300

1300

S

1200

1300

1300

1300

Z

1000

1000

1000

1000

Service Space(mm)

Page 13: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

24Centrifugal Chiller23 Centrifugal Chiller

INSULATION

Note: The gray area need to be insulated. Normally the chiller is insulated in the factory. If the chiller has to be insulated in the jobsite, it must ensure that:• Moveable components and parts shouldn’t be affected by insulation.• Please don’t leave connecting bolt in insulation.• Please don’t leave name plate in insulation.• Please open water box cover when clean the evaporator tubes.

REFRIGERATION CYCLE

Refrigeration systemMidea LC centrifugal chiller is the steam-compressing cycle type. The refrigerant will be imposed vertical energy by the high speed impeller to increase its temperature and pressure. The high pressure and temperature refrigerant gas will release its thermal energy to the cooling water in condenser, thus decrease its temperature. After throttled by the orifice its pressure will be decreased dramatically. In evaporator the low temperature and low pressure refrigerant will absorb the thermal energy from the chilled water to evaporating. The low temperature chilled water produced in this refrigeration circulation. One refrigeration circulation includes four indispensable processes: compressing, condensing, throttling and evaporating.

Page 14: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

26Centrifugal Chiller25 Centrifugal Chiller

MICROPROCESSOR CONTROL

Microprocessor controlProfessional designed microprocessor controller combine with state-of-the-art control logic provide the safety, capacity control, interlock, and indications necessary to operate the chiller in a safe and efficient performance. The microprocessor control in Midea centrifugal system is factory mounted, wired, and tested to ensure machine operation in a proper condition and meets the programmed control logic.

Control systemTouchable screen, graphical display and convenient operationMenu-driven keypad interfaceComponent test and diagnostic functionProgrammable Logic Controller, optimize performanceDisplay operation parameters Real time monitoring function Precise pressure and temperature controlMore than 30 items of protections and alarmsLanguages pre-programmed at factory for English, ChinesePrecise design and compact layout Modular construction easy for maintenanceRS485 compatible, maximum 32 chillers and accessory equipments can be centralized

Basic Indication ItemsChilled water inlet temperatureChilled water outlet temperatureCooling water inlet temperatureCooling water outlet temperatureCondensing pressureEvaporating pressureOil supply temperatureOil supply pressureOil sump temperatureOil sump pressureOil supply pressure differenceInlet guide vane openingRunning current (percentage)Total power on timeTotal running timeTotal start-up time

Capacity ControlMinimum IGV opening controlMaximum main motor current controlLeaving chilled water temperature controlInlet guide vane actuator Manual mode option

User SettingsRestart temperaturePause temperatureCurrent limitFull load/rated loadChilled water outlet temperatureRated motor currencySystem control modeLow oil supply pressure difference (before start)Low oil supply pressure difference (after start)Minimum oil supply pressure difference.Minimum oil sump temperatureHigh oil supply temperatureMaximum oil supply temperatureLow evaporation pressureMinimum evaporation pressureHigh condensing temperature Maximum condensing temperature Low chilled water outlet temperatureCritical inlet guide vane openingCritical water temperature Note:Setting values refer to user manual

Safety CutoutsThe all protection control, if necessary, shuts the chiller off or limits the open of inlet guide van to protect the chiller from possible damage.

Inadequate oil supply pressure difference.Excessive oil supply temperatureInadequate oil sump temperatureOil pump current overloadInadequate chilled water flow Low chilled water outlet temperatureCompressor motor current overload Excessive main motor winding temperatureExcessive Start time Inadequate evaporation pressureExcessive condensing pressure Temperature transmitter faultsPressure transmitter faultsStarter faultsPhase unbalance, phase loss, phase reversalUnder voltageOver voltage

Page 15: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

28Centrifugal Chiller27 Centrifugal Chiller

STANDARD PROTECTION

Low Supply Oil-pressure Difference ProtectionOil pressure is indication of oil flow and oil-pump operation. A significant drop in oil pressure difference indicates a failure of the oil pump, oil leakage, or other blockage in the oil-circuit. The differential pressure during compressor pre-lube mode should not fall below set point. A failure on meets this requirement leads to inhibit the start of the chiller. When the compressor is running, an alarm will be displayed if the differential pressure is below set point. And if this value decreases to the minimum set point the chiller will shut-down.

Oil-Temperature ProtectionHigh oil temperature when the oil pump and/or compressor are running may be an indication of oil-cooler failure, overheating of the oil and the bearings, or oil filter blockage. If the oil temperature continuous increase to the maximum set point, the chiller will shut-down. The start of the compressor will be inhibited if the oil sump temperature is below the set point. The diagnostic will display at the user interface.

Oil Pump Current Overload ProtectionThe oil pump control panel will monitor the current of oil pump, and shut the chiller off when the oil pump current exceeds its maximum set point.

High Condenser-Pressure Protection The chiller controller’s algorithm keeps the condenser pressure under a specified maximum pressure. The chiller can run up to 100 percent of this setpoint in a safe and reliable condition. If the condenser pressure exceeds the set point, the system will prohibit the open of the inlet guide vane to decrease the pressure or shut off the chiller immediately according to the different set point.

Low Evaporator-Pressure Protection The chiller controller’s algorithm keeps the evaporator pressure under a specified minimum pressure. The chiller can run up to 100 percent of this setpoint in a safe and reliable status.If the evaporator pressure decreases below the set point, the system will prohibit the open of the inlet guide vane to increase the pressure or shut off the chiller immediately according to the different set point.

Water Flow ProtectionThe water flow switches is required to install in the water piping system. The chiller controller has a digital input that will indicate the water flow. When this input does not prove flow within a fixed time during the starting, the process will be terminated. If the flow is lost while the chiller is in running, the system will shut the chiller off to protect the chiller from possible damage.

Current Overload ProtectionThe control panel will monitor the current drawn by each line of the motor and if the highest of the three line currents exceeds 110% of the rated current, the system will close the inlet guide vane automatically and check whether the current decrease to normal condition. And the system will shut the chiller off if the highest of the three line currents exceeds 115% of the rated current. The current overload protection does not prohibit the chiller from reaching its full-load ampere.

High Motor-Winding Temperature ProtectionThis function monitors the motor temperature and terminates chiller operation when the temperature is excessive. The controller monitors the winding-temperature sensors any time the controller is energized. And immediately shut the chiller off if the temperature surpasses the maximum set point.

Start Time Limit ProtectionWhen start the chiller, if the time from Wye connection change to Delta connection exceeds set point. The system will shut the chiller off immediately to protect the chiller from possible damage.

Power Supply ProtectionA factory installed transformer or power supply protection module in the starter, if any overvoltage or undervoltage, phase-unbalance, phase-loss, phase reversal happens, the control system will detect it and shut the chiller off in time.

Starter Failure ProtectionThe chiller will protect itself from a starter failure,that ensures the compressor motor disconnecting from the line when the motor reach the limits of its capabilities. The controller starts and stops the chiller through the starter. If the starter malfunctions and does not disconnect the compressor motor from the line in an emergency situation, the controller will recognize the fault and shut the chiller off immediately.

Low Chilled Water Outlet Temperature ProtectionLow chilled water outlet temperature protection, also known as anti-freeze protection, avoids water freezing in the evaporator by immediately pause the chiller if the chilled water outlet temperature reaches its minimum allowable value. After the chilled water inlet temperature reach the restart set point, the chiller will start automatically. This protection may be due to the sensor fault, incorrect set point of chilled water outlet temperature or lack of chilled water flow.

Page 16: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

30Centrifugal Chiller29 Centrifugal Chiller

CENTRALIZED CONTROL

The chillers realize the centralized control by using the RS422/RS484 communication port and the DDC control panel. Maximum 32 chillers can be centralized integrate with the relevant cooling water pumps, chilled water pumps and cooling towers. It includes the reading and writing of data that allow system monitor, control and alarm as programmed. Also the system can be connected to the DCS/BAS/IBMS/SCADA and achieve remote control.

• Adjustment of chiller operation setpoints.• Real time inspect and supervision of chiller operation state.• Real time failure inspects.• Historical operation data memory

TYPICAL WIRING DIAGRAM

RS485

Page 17: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

32Centrifugal Chiller31 Centrifugal Chiller

380V-3N-50HZ 5KVA

Starter Wiring Diagram (Typical)

Oil Pump Wiring Diagram (Typical)

Page 18: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

34Centrifugal Chiller33 Centrifugal Chiller

10kV

YJV2225

YJV2225

YJV2235

YJV2235

YJV2235

YJV2235

YJV2235

YJV2235

YJV2250

YJV2250

YJV2250

YJV2250

YJV2250

YJV2270

YJV2270

YJV2250

YJV2250

YJV2250

YJV2250

YJV2270

YJV2270

YJV2270

6kV

YJV2235

YJV2235

YJV2250

YJV2250

YJV2250

YJV2250

YJV2250

YJV2250

YJV2270

YJV2270

YJV2270

YJV2270

YJV2270

YJV2295

YJV2295

YJV2270

YJV2270

YJV2270

YJV2270

YJV2295

YJV2295

YJV2295

Auto-transformer in/out

2×BVR150

2×BVR150

2×BVR240

2×BVR240

2×BVR240

2×BVR300

2×BVR300

2×BVR300

3×BVR240

3×BVR240

3×BVR240

3×BVR240

3×BVR300

3×BVR300

4×BVR240

4×BVR240

4×BVR240

Y-∆ Cable out

BVR185

BVR185

BVR300

BVR300

BVR300

2×BVR120

2×BVR150

2×BVR150

2×BVR185

2×BVR185

2×BVR240

2×BVR240

2×BVR240

2×BVR240

2×BVR300

2×BVR300

2×BVR300

Y-∆ Cable in

2×BVR150

2×BVR150

2×BVR240

2×BVR240

2×BVR240

2×BVR300

2×BVR300

2×BVR300

3×BVR240

3×BVR240

3×BVR240

3×BVR240

3×BVR300

3×BVR300

4×BVR240

4×BVR240

4×BVR240

Model

LC350M

LC400M

LC450M

LC500M

LC550M

LC600M

LC650M

LC700M

LC750M

LC800M

LC850M

LC900M

LC950M

LC1000M

LC1100M

LC1200M

LC1300M

LC1400M

LC1500M

LC1600M

LC1700M

LC1200MS

LC1350MS

LC1500MS

LC1650MS

LC1800MS

LC1900MS

LC2000MS

380V High Voltage

NOTE:1. The table listed the recommended cable cross section, mm2.2. Use copper cable only. 3. Application must in accordance with IEC standard and local or national regulations.

Recommended Cable Size

TYPICAL PIPING AND CABLE LAYOUT

Choose the proper power supply cable size and tag clearly.

Filter must be used in the water system.

Thermometer and pressure meter must be installed in the water system.

Recommend to use a steel pipe to connect the security release valve to the outside.

Recommend to use an oxygen density indicator that alarm automatically when the density lower than 19.5%.

Cable and pipe layout should be done based on local regulation.

Page 19: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

36Centrifugal Chiller35 Centrifugal Chiller

MECHANICAL SPECIFICATION

CompressorSingle-stage centrifugal compressor with high-strength aluminum alloy fully shrouded impellers and moveable inlet guide van. The enclosed type impeller is designed for balanced thrust and is dynamically balanced and overspeed tested for smooth, vibration free operation. Airfoil shaped inlet guide vane minimize flow disruption for the most efficient part load performance.The movement of the inlet guide vane is controlled by a mounted electric actuator in response to refrigeration load on the evaporator. The rotor assembly consists of a heat-treated alloy steel drive shaft with a high strength, and the high speed shaft is forged with high strength and reliability.

MotorMidea centrifugal chiller use semi-hermetic two-pole motor and is cooled by the circular refrigerant, winding embedded sensors provide positive thermal protection to the motor. Asynchronism squirrel cage type motor can achieve higher operation performance and longer life span. Refrigerant cooled motor keeps motor heat out of the mechanical room, decrease vibration and shaft seal maintenance compare with open motors. Also refrigerant cooled motor have lower inrush currents and lower noise than open motor which cooled by air, there is no need to provide additional ventilation or air conditioning for the mechanical room than open motor design. The motor is bolt connected to the compressor gear housing and shaft labyrinth seal prevents refrigerant leakage from the motor to the gear box. Low voltage motor provides 6 terminals for reduce starting voltage (wye-delta or auto transformer start). High voltage motor provides three terminal posts for full voltage (across the line). Motor terminal pads are supplied. A moveable steel sheet terminal box encloses the terminal board area to insulation.

Impeller And Inlet Guide VaneHigh strength aluminum-alloy compressor impellers feature backward-curved vanes for high efficiency Airfoil shaped inlet guide vane minimize flow disruption for the most efficient part load performance. Precisely positioned and tightly fitted, it allows the compressor to unload smoothly from 10% to 100% load output for excellent operation in real air conditioning application. The movement is controlled by a mounted electrical operator in response to refrigeration load on the evaporator. Impeller is made of high strength aluminum alloy which is tested at 125% design operating speed.

Heat Exchanger TubeHeat exchanger tubes are high-efficiency, externally and internally enhanced type to provide optimum performance. Tubes in both the evaporator and condenser are 3/4" O.D. copper alloy providing an internal and external surface. This provides extra wall thickness (up to twice as thick) and non-work hardened copper at the support location, extending the life span of the heat exchanger. Each tube is roller expanded into the tube sheets providing a leakproof seal, and is individually replaceable. Copper alloy material as a standard choice and 90/10 copper-nickel, 304stainless steel or titanium material can be customized.

EvaporatorThe evaporator is a shell and tube type heat exchanger. A flow equalizer provides uniform distribution of refrigerant over the entire tube length to yield optimum heat transfer. The evaporator shell contains a dual refrigerant relief valve arrangement set at 185 PSIG (1280 kPa) or single-relief valve arrangement. Intermediate tube support sheets positioned along the shell axis prevent relative tube motion. The waterside is hydraulic tested at 1.5 times of the maximum working pressure.

CondenserThe condenser is shell and tube type, with discharge gas baffle to prevent direct high velocity gas impingement on the tubes. The baffle is also used to distribute the refrigerant gas flow properly for most efficient heat transfer. An integral sub-cooler is located at the bottom of the condenser shell providing highly effective liquid refrigerant subcooling to provide the highest cycle efficiency. Regarding the duel-stage compressing, using the economizer can improve the efficiency by 5-8%. The condenser contains a refrigerant relief valve sets at 1.6 MPa. Standard maximum waterside working pressure is 1.0 MPa. The waterside is hydraulic tested at 1.5 times of maximum working pressure.

Page 20: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

38Centrifugal Chiller37 Centrifugal Chiller

Water BoxThe removable water boxes are fabricated of steel. The design working pressure is 150 PSIG (1034 kPa) and the boxes are tested at 225 PSIG (1551 kPa). Integral steel water baffles are located and welded within the water box to provide the required pass arrangements. The nozzle connections are suitable for flanges and are capped when shipment. Plugged 3/4" drain and vent connections are provided in each water box.

Orifice For proper refrigerant flow control and reliablethrottling, Midea “smart star” design applies a fixed single-hole orifice system. It eliminates thermal expansion valves, float valves, and other moving parts. Since there are no moving parts, it can achieve high reliability and minimum the possibility of failure.

Control PanelMidea adopts the state-of-the-art microprocessor control system with 10.4 inch LCD touchable screen and high disturbance resistance. The LCD touchable screen with graphical display of chiller parameters, fast and easy to access makes the operation relatively simple. It also can communicate with the user's PC and carry out the remote control for start, operation and stop of the cooling system. More than 30 item protections and malfunctions used to make the chiller operation secure and reliable. The latest 10 items of failure information can be recorded for inquiry.

Lubrication System A separately driven electric oil pump assembly supplies lube to the compressor at proper temperature and pressure .After filtration the lube been pressed to the oil cooler to cooling it to certain temperature. And then adjust its pressure before transmitted to bearings. Special designed seals are installed at inner side of motor bearings at both ends to

minimize the lube that leaked into the main motor and mixed into the R134a in evaporator. Besides, electric heater is used inside the oil tank to maintain the oil in proper temperature all the time. In this way, when the compressor shuts down, certain oil temperature can be maintained. Thus prevent the R134a gas from entering the oil to decrease the efficiency of lubrication. Therefore, while the compressor is shut down, it is necessary to keep oil heater on to make the oil temperature in certain temperature. If the compressor will out of service for a long time, it is required to run the oil heater to maintain the proper oil temperature.

OIL CLAIM

reclaim system

During the running of refrigeration unit, it is inevitable that a small amount of lube interfuses into the refrigerant, especially when the cooling load is very low. The mixed oil-refrigerant goes through compressor bearings and gearbox, and then interfuses into the condenser. Because the density of lube is higher than refrigerant, after the refrigerant was evaporated the lube will float on the liquid refrigerant. Midea patent designed oil reclaim device is factory mounted below the condenser. The oil reclaim system is capable of return the oil from the heat exchanger back to the oil tank with high efficiency. Thus it will improve the refrigerant purity to increase the efficiency of chiller and supply sufficient oil to compressor.

Note:〇:on ×:off △:micro open K1、K5、K10 keep open

K9

×

×

×

K8

×

×

×

K7

×

×

×

K6

×

×

×

K4

×

K2 and K3

×

×When oil reclaim system not used

Automatic

Oil reclaimManual

ValveProcess

Separation of refrigerant and oil

No.

1

2

3

Page 21: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

40Centrifugal Chiller39 Centrifugal Chiller

OPTIONSAcross the line starter Auto-transformer starter Higher water side pressure, 1.6MpaCommunication protocol: Hostlink/Modbus.10kV power supply for 650~2000RT ABB high voltage vacuum contactor and protection moduleRefrigerant isolation valves on condenserCustomized pass on evaporator/condenserCustomized marine water box on evaporator/condenserSectional shipmentSpring vibration isolation Evaporator shell is 1-1/2 Inch (40mm) insulationEvaporator/condenser water pipe victaulic connectionFouling factor: Evaporator 0.0172~0.344m2k/kW, condenser 0.044~0.344m2k/kW.

Note:Some of the options list above may not be useful for specific regions.

SELECTION SOFTWARE

For optimize the configuration and performance of Midea product, as well as to match the actual requirements of your HVAC system. Midea launched its first generation chiller products selection software at the end of 2010. This independent software can select the best components configuration according to the requirement of your HVAC system. After input the general parameters such as cooling capacity, fouling factor, pass number, power supply, etc. Nominal data and physical data for typical compressor-evaporator - condenser combinations are given by product list. Midea R&D fellow and software engineers will update the improvement information of the product online in time, and our customer can get the update information through the internet.

Part load performance CurveSelection output

CONVERSION TABLE

Celsius

39.0

40.0

41.0

42.0

43.0

44.0

45.0

46.0

47.0

48.0

49.0

50.0

51.0

52.0

53.0

54.0

55.0

56.0

57.0

58.0

59.0

60.0

61.0

62.0

63.0

64.0

65.0

66.0

67.0

68.0

69.0

70.0

71.0

72.0

Fahrenheit

102.2

104.0

105.8

107.6

109.4

111.2

113.0

114.8

116.6

118.4

120.2

122.0

123.8

125.6

127.4

129.2

131.0

132.8

134.6

136.4

138.2

140.0

141.8

143.6

145.4

147.2

149.0

150.8

152.6

154.4

156.2

158.0

159.8

161.6

Celsius

5.0

6.0

7.0

8.0

9.0

10.0

11.0

12.0

13.0

14.0

15.0

16.0

17.0

18.0

19.0

20.0

21.0

22.0

23.0

24.0

25.0

26.0

27.0

28.0

29.0

30.0

31.0

32.0

33.0

34.0

35.0

36.0

37.0

38.0

Fahrenheit

41.0

42.8

44.6

46.4

48.2

50.0

51.8

53.6

55.4

57.2

59.0

60.8

62.6

64.4

66.2

68.0

69.8

71.6

73.4

75.2

77.0

78.8

80.6

82.4

84.2

86.0

87.8

89.6

91.4

93.2

95.0

96.8

98.6

100.4

Celsius

-29.0

-28.0

-27.0

-26.0

-25.0

-24.0

-23.0

-22.0

-21.0

-20.0

-19.0

-18.0

-17.0

-16.0

-15.0

-14.0

-13.0

-12.0

-11.0

-10.0

-9.0

-8.0

-7.0

-6.0

-5.0

-4.0

-3.0

-2.0

-1.0

0.0

1.0

2.0

3.0

4.0

Fahrenheit

-20.2

-18.4

-16.6

-14.8

-13.0

-11.2

-9.4

-7.6

-5.8

-4.0

-2.2

-0.4

1.4

3.2

5.0

6.8

8.6

10.4

12.2

14.0

15.8

17.6

19.4

21.2

23.0

24.8

26.6

28.4

30.2

32.0

33.8

35.6

37.4

39.2

Formulas: C = (F - 32) × 5 / 9, F = (C × 9 / 5) + 32

Temperature:℉—℃

Page 22: COMMERCIAL AIR CONDITIONERS - tahviehsepidar.comtahviehsepidar.com/wp-content/uploads/2015/05/Centrifugal-Chiller.pdf · 07 Centrifugal Chiller Centrifugal Chiller 04 CONTENTS MIDEA

42Centrifugal Chiller41 Centrifugal Chiller

PSI

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

11.0

12.0

13.0

14.0

15.0

16.0

17.0

18.0

19.0

20.0

21.0

22.0

23.0

24.0

25.0

26.0

27.0

28.0

29.0

30.0

31.0

32.0

33.0

34.0

35.0

36.0

37.0

38.0

39.0

40.0

kPa

6.89

13.79

20.68

27.58

34.47

41.37

48.26

55.16

62.05

68.95

75.84

82.74

89.63

96.53

103.42

110.32

117.21

124.11

131.00

137.90

144.79

151.68

158.58

165.47

172.37

179.26

186.16

193.05

199.95

206.84

213.74

220.63

227.53

234.42

241.32

248.21

255.11

262.00

268.90

275.79

kg/m2

0.07

0.14

0.21

0.28

0.35

0.42

0.49

0.56

0.63

0.70

0.77

0.84

0.91

0.98

1.05

1.12

1.20

1.27

1.34

1.41

1.48

1.55

1.62

1.69

1.76

1.83

1.90

1.97

2.04

2.11

2.18

2.25

2.32

2.39

2.46

2.53

2.60

2.67

2.74

2.81

PSI

41.0

42.0

43.0

44.0

45.0

46.0

47.0

48.0

49.0

50.0

51.0

52.0

53.0

54.0

55.0

56.0

57.0

58.0

59.0

60.0

61.0

62.0

63.0

64.0

65.0

66.0

67.0

68.0

69.0

70.0

71.0

72.0

73.0

74.0

75.0

76.0

77.0

78.0

79.0

80.0

kPa

282.69

289.58

296.47

303.37

310.26

317.16

324.05

330.95

337.84

344.74

351.63

358.53

365.42

372.32

379.21

386.11

393.00

399.90

406.79

413.69

420.58

427.47

434.37

441.26

448.16

455.05

461.95

468.84

475.74

482.63

489.53

496.42

503.32

510.21

517.11

524.00

530.90

537.79

544.69

551.58

kg/m2

2.88

2.95

3.02

3.09

3.16

3.23

3.30

3.37

3.45

3.52

3.59

3.66

3.73

3.80

3.87

3.94

4.01

4.08

4.15

4.22

4.29

4.36

4.43

4.50

4.57

4.64

4.71

4.78

4.85

4.92

4.99

5.06

5.13

5.20

5.27

5.34

5.41

5.48

5.55

5.62

PSI

81.0

82.0

83.0

84.0

85.0

86.0

87.0

88.0

89.0

90.0

91.0

92.0

93.0

94.0

95.0

96.0

97.0

98.0

99.0

100.0

101.0

102.0

103.0

104.0

105.0

106.0

107.0

108.0

109.0

110.0

111.0

112.0

113.0

114.0

115.0

116.0

117.0

118.0

119.0

120.0

kPa

558.48

565.37

572.26

579.16

586.05

592.95

599.84

606.74

613.63

620.53

627.42

634.32

641.21

648.11

655.00

661.90

668.79

675.69

682.58

689.48

696.37

703.27

710.16

717.05

723.95

730.84

737.74

744.63

751.53

758.42

765.32

772.21

779.11

786.00

792.90

799.79

806.69

813.58

820.48

827.37

kg/m2

5.69

5.77

5.84

5.91

5.98

6.05

6.12

6.19

6.26

6.33

6.40

6.47

6.54

6.61

6.68

6.75

6.82

6.89

6.96

7.03

7.10

7.17

7.24

7.31

7.38

7.45

7.52

7.59

7.66

7.73

7.80

7.87

7.94

8.01

8.09

8.16

8.23

8.30

8.37

8.44

PSI

121.0

122.0

123.0

124.0

125.0

126.0

127.0

128.0

129.0

130.0

131.0

132.0

133.0

134.0

135.0

136.0

137.0

138.0

139.0

140.0

141.0

142.0

143.0

144.0

145.0

146.0

147.0

148.0

149.0

150.0

151.0

152.0

153.0

154.0

155.0

156.0

157.0

158.0

159.0

160.0

kPa

834.27

841.16

848.06

854.95

861.84

868.74

875.63

882.53

889.42

896.32

903.21

910.11

917.00

923.90

930.79

937.69

944.58

951.48

958.37

965.27

972.16

979.06

985.95

992.85

999.74

1006.63

1013.53

1020.42

1027.32

1034.21

1041.11

1048.00

1054.90

1061.79

1068.69

1075.58

1082.48

1089.37

1096.27

1103.16

kg/m2

8.51

8.58

8.65

8.72

8.79

8.86

8.93

9.00

9.07

9.14

9.21

9.28

9.35

9.42

9.49

9.56

9.63

9.70

9.77

9.84

9.91

9.98

10.05

10.12

10.19

10.26

10.34

10.41

10.48

10.55

10.62

10.69

10.76

10.83

10.90

10.97

11.04

11.11

11.18

11.25

Formulas: 1psi≈6.894757 kpa 1psi≈0.070306958kg/m2

Pressure: PSI—kPa—kg/m2