commercial heating and cooling rrcf- cooling only rref-...

20
12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW] STANDARD RATING 150 & 176 MBH Commercial Heating and Cooling Package Units RRCF- Cooling Only RREF- Electric Heat RRGF- Gas Heat FORM NO. R11-818 REV. 5 Supersedes Form No. R11-818 Rev. 4

Upload: others

Post on 03-Nov-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

12.5 & 15 NOMINAL TON UNITS[44 & 52.8 kW]

STANDARD RATING 150 & 176 MBH

CommercialHeating and CoolingPackage UnitsRRCF- Cooling OnlyRREF- Electric HeatRRGF- Gas Heat

FORM NO. R11-818 REV. 5Supersedes Form No. R11-818 Rev. 4

Page 2: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

2

R RG F- 200 125 C K RType of Gas (Canadian)R–Natural (A–Natural)

Drive PackageK–StandardL–Optional

Electrical CharacteristicsC–3/60/208/230D–3/60/460Y–3/60/575 (Canadian)

Nominal Tons Cooling Capacity125–12.5 Tons [44 kW]150–15.0 Tons [52.8 kW]

Electric Heat–Total kW020-20 kW

(12.5 Ton Models Only) [44 kW]030–30 kW040–40 kW060–60 kW090–90 kW

(15 Ton Models Only) [52.8 kW]

Gas Heat200–200,000 BTUH [58.6 kW]

(12.5 Ton Models Only) [44 kW]250–250,000 BTUH [73.3 kW]350–350,000 BTUH [103 kW]

(15 Ton Models Only) [52.8 kW]

Series NumberF–New Design Series

Rooftop–Type HeatingRG-GasRE-ElectricRC-Cool Only

Rheem

[ ] Designates Metric Conversions

TABLE OF CONTENTS

Model Number Designation ....................................................2General Description ..............................................................3Unit Features ........................................................................3Accessories ..........................................................................3Physical Data ........................................................................4General Information & Corner Weights ....................................5Unit Dimensions ..............................................................6 & 7Accessory Dimensions ......................................................8-10Performance Data ................................................................11Selection Procedure ............................................................12Cooling Performance Data ....................................................13Indoor Blower Performance ..........................................14 & 15Electrical Data ....................................................................16Typical Wiring Schematics ................................................17-19Limited Warranty..................................................................20Sample Specification............................................................20

MODEL NUMBER DESIGNATION

RRGF- SERIESFRONT AND REAR VIEWS

NOTE: “Y”-575 VOLTMODELS NOTU.L. LISTED.

575 VOLTMODELS ONLY

“CERTIFIED UNDER THEA.R.I. CERTIFICATION

PROGRAM—A.R.I.STANDARD 360”

A NEW BREED OF ROOFTOPS DESIGNED FOR THE 90’S.Rheem® combined years of proven product reliability and high tech engineering to develop this line of versatile rooftops. Thisresulted in a flexible design with the features of earlier models in a fully accessible, totally new compact cabinet.

Page 3: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

3[ ] Designates Metric Conversions

GENERAL DESCRIPTIONThe Rheem RRCF-, RREF- and RRGF- series rooftops are designed foroutdoor installation. Their cabinets and condenser base pans are powdercoat painted. Cabinets are fully insulated and gasketed to resist all types ofweather conditions. All models are shipped ready for downflow duct appli-cation requiring no additional labor to remove panels. For sideflow ducting,duct cap panels are easily repositioned in the field. Economizer and freshair damper accessories are designed for use in either duct configuration.The units are evacuated to remove moisture from the refrigeration system,precisely charged with the refrigerant and run tested at the factory prior toshipment.

RRGF-The combination rooftops provide comfort conditioning in all seasons. Twoseparate cooling circuits supply cool air to meet the demands of hot sum-mer days. One cooling circuit operates independently to satisfy the needson warm spring and fall days. The gas furnace furnishes two stages ofheat during cold winter weather. For those cool nights when full capacity isnot needed, the first stage heat operates to produce the right amount ofwarm air.

RREF-The electric heat models offer the same cooling characteristics and fea-tures as the gas heat models but factory installed electric heating elementswarm the building supply air. The electric heaters are designed for twostages of heat and are wired to balance the electrical load across the threephase power. Unit mounted terminal blocks and internal branch fusingallow single point external power wiring which eliminates the need for sep-arate power circuits to the electric heater and the cooling sections, thusreducing installation costs.

RRCF-The cooling only models deliver high efficiency cooling in two capacitysteps. A wide range of electric heat accessories can be field installed inthe unit to satisfy heating requirements. All operating parts of the unit areaccessible through exterior panels. The control components are mountedin one conveniently located control box. The control box and compressoraccess panel can be removed for servicing without interfering with con-denser air flow.

FEATURESENCLOSURE• Galvanized steel.• Powder coat painted cabinet and condenser base pan, capable of with-

standing a 1000-HR salt spray test per ASTM B 117.• Indoor section panels insulated with high density glass fiber.• Louvered inlet panels protecting condenser coil are standard.• Weather tight construction.

COMPRESSORS• Two sealed hermetics, in separate refrigerant circuits, have internal over-

load protection.• Internal spring and external rubber mounts provide compressor isolation.• Insert type crankcase heaters standard.• High and low pressure controls.

CONDENSER COIL• Four row copper tubes with mechanically bonded aluminum plate fins.• Two-row, circuited for two refrigerant systems.

CONDENSER FAN• Vertical discharge, direct drive.• Permanently lubricated “PSC” motor has inherent thermal overload.• Discharge grille easily removable for access to fan, motor and coil.

EVAPORATOR COIL• Copper tubes with mechanically bonded aluminum plate fins.• Four row, two circuit, interlaced design provides full-face cooling at

part load.• Refrigerant flow control by thermal expansion valves.• Galvanized steel drain pan with threaded connector on side.

FILTERS• Filter frame holds 2" [50.8 mm] filters—throwaway type provided.• Access panel and unique clip arrangement allows easy replacement.

INDOOR BLOWER• Adjustable belt drive, forwardly curved centrifugal fan.• Alternate motors and drives available to meet job requirements.• Motor and fan shaft have permanently lubricated ball bearings.

ELECTRICAL• Control box easily accessible for power and control connections.• Factory wiring provides terminal strips and remote plugs with designated

jumpers for easy, fool-proof, accessory installation.• Single point power wiring.

GAS HEAT• Natural gas.• Aluminized steel tubular heat exchangers.• In-shot burners with induced draft combustion air have spark ignition

(100% Lockout) system.• Two stage heating.

ELECTRIC HEAT• Five sizes available ranging from 20 kW to 90 kW.• Factory installed in RREF- models complete with wiring and appropriate

fuses.• Field installed electric heat available for use in RRCF- model.

APPLICATION• Cooling operation to 45°F [7.2°C]. Field add low ambient controls.• Shipped for vertical airflow—relocate two panels for horizontal.

QUALITY ASSURANCE• All production units are run tested at the factory.• Certified to applicable ARI Standards.• Listed to applicable U.L. and CSA Standards, tested in accordance with

ANSI Standard Z21.47.

ACCESSORIESRXRK-E56 ROOF CURB—Full perimeter curb with insulation panel underoperating components provides for duct attachment prior to setting unit.Complies with NRCA Standards.

RXRF-CA56 MANUAL FRESH AIR DAMPER—Fixed position, fieldadjustable (0-25%) fresh air damper.

RXRQ-FM56Z ECONOMIZER—Fully modulating, integrated, enthalpycontrolled, with major parts pre-assembled and wired for plug-in installa-tion. Suitable for horizontal or vertical airflow application. Factory installedoption.

RXRP-E56 RELIEF DAMPER—Gravity operated damper and hoodassembly for use with economizer to relieve positive building pressure.

RXRT-C54 LOW AMBIENT—Two condensing pressure actuatedswitches, cycle condenser fan in response to pressure of operating cycle.Wire to terminal strip; connect capillaries to Schrader valves.

RXRW-C55 COMBINATION TIME DELAY BETWEEN COMPRESSORSAND ANTI-SHORT CYCLE TIMER—Instructions and components to pro-vide 5 minute delay and staging relay.

RXSE-BF ELECTRIC HEAT—Complete assembly includes elements,controls and wiring. Mounts in prepared area of RRCF- model. Designedfor single point power wiring.

RXRM-EB56 CONCENTRIC TRANSITION—Drops in roof curb prior toplacing unit. Directs supply air around the perimeter of center return duct.

RXRN-EE56 CONCENTRIC GRILLE—Used in conjunction with the con-centric transition. Grille mounts to the concentric ducts at ceiling level.

RXRJ-GP05W GAS CONVERSION KITS—Converts Natural gas units tooperate on Propane gas.

RXRJ-GP06W GAS CONVERSION KITS—Converts Natural gas units tooperate on Propane gas. (High altitude Canadian models only).

WALL THERMOSTAT—24 volt, 2 stage cool, 2 stage heat (Part #41-21444-01) with subbase, automatic (Part #41-21445-01) or manual (Part#41-21443-02); fan on or auto.

REMOTE STATUS PANEL—Kit includes remote panel with indicatorlights, potentiometer and system switches, also has room thermostat forremote sensing and adjustment, Part #41-21946-12.

REMOTE INDICATOR PANEL—Panel has indicator lights to show fancooling and heating operations, Part #41-21946-01.

Page 4: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

4

Compressors–Hermetic (No.)

Condenser Coils (No.)

2

Capacity Stages–(%)

2

66/100

Refrigerant Charge/Circuit (Oz. R-22)

2

320/160

Condenser Fans (No.) 3

CFM [L/s] Total 10,800 [5097]

MODEL RRCF-/RREF-/RRGF- COOLING DATA

9

350,000 [102.6]

Diameter–(In.) [mm]/Blades (No.)

Nominal Cooling Capacity–(Tons) [kW] 12.5 [44.0]

22 [559]/3

Motor HP [W]/RPM 1/3 [248.6]/1075

Face Area–Sq. Ft. [m2]–Total 45.5 [4.2]

Rows/Fins Per In.–Total 2/22

Tube Dia.–(In.) [mm] .375 [9.5]

Indoor Blower (No.) 1

CFM [L/s]–Nom. 5000 [2360]

Wheel–Dia./Width–(In.) [mm] 18/15 [457/381]

Motor HP [W]–Std./Alt. 2/3 [1491/2237]Motor RPM 1725

Evaporator Coil (No.) 1

Face Area–Sq. Ft. [m2]–Total 16.9 [.49]

Rows/Fins Per Inch 4/13

Tube Dia.–(In.) [mm] .375 [9.5]

Filters–(No.) Size ea.–(In.) [mm] (6) 20 x 20 x 2 [508 x 508 x 50.8]

Crated Unit Dimensions–(In.) [mm] 51.75H x 86W x 124.25L [1314 x 2184 x 3156]

Shipping Weight (lbs.) [kg]RRCF- Cool Only 1740 [789.3]

RRGF- Gas Heat 1960 [889.0]

Operating Weight (lbs.) [kg]RRCF- Cool Only 1500 [680.4]

RRGF- Gas Heat 1720 [780.2]

MODEL RRGF- GAS HEATING DATAHeating Input–BTUH [kW] 200,000 [58.6]

Heat Exchanger Tubes–(No.) 5

Capacity Stages–(%) 50/100

Thermal Efficiency–(%) 80

MODEL RREF- ELECTRIC HEATING DATA80

50/100

6

250,000 [73.3]

1800 [816.5]

1540 [698.5]

2040 [925.3]

1780 [807.4]

(6) 20 x 20 x 2 [508 x 508 x 50.8]

.375 [9.5]

4/13

16.9 [.49]

1

17253/5 [2237/3728]

18/15 [457/381]

6000 [2832]

1

.375 [9.5]

2/22

45.5 [4.2]

1/3 [248.6]/1075

22 [559]/3

10,800 [5097]

3

352/176

66/100

2

15 [52.8]

51.75H x 86W x 124.25L [1314 x 2184 x 3156]

280,000 [82.1]Heating Output–BTUH [kW] 160,000 [46.9] 200,000 [58.6]

250,000 [73.3]

200,000 [58.6]

6

Heater Size Designation **020** 030 040 060

kW Input @

208V 15.0 21.6 30.0 43.2

240V 20.0 28.8 40.0 57.6

480V 20.0 28.8 40.0 57.6

600V — 28.8 — 57.6

Heating Capacity–MBH @

208V 51.2 73.7 102.3 147.4

240V 68.2 98.3 136.4 196.6

480V 68.2 98.3 136.4 196.6

600V — 98.3 — 196.6

Capacity Stages* 2 2 2 2

Nominal Cooling Capacity–(Tons) [kW] 12.5[44.0]

Shipping Weight (lbs.) [kg] 1785[809.7]

Operating Weight (lbs.) [kg] 1545[700.8]

12.5[44.0]

12.5[44.0]

12.5[44.0]

1800[816.5]

1795[814.2]

1790[811.9]

1560[707.6]

1555[705.3]

1550[703.1]

15[52.8]

***090***

64.8

86.4

86.4

1860[843.7]

86.4

221.1

294.9

294.9

1620[734.8]

294.9

2

Element Material Helix Wound Nickel Chrome Wire

15[52.8]

15[52.8]

15[52.8]

1830[830.1]

1835[832.3]

1840[834.6]

1590[721.2]

1595[723.5]

1600[725.7]

PHYSICAL DATA

*** First stage heating is 50% of total capacity.*** For RREF- 12.5 ton [44.0 kW] unit only.*** For RREF- 15 ton [52.8 kW] unit only.

[ ] Designates Metric Conversions

Page 5: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

5

GENERAL INFORMATIONLOCATING UNITConsult local building codes or ordinances for special installationrequirements. When selecting a site to locate the rooftop unit, con-sider the following:

ROOF MOUNTIf unit is to be roof mounted, check building codes for weight distri-bution requirements. Refer to accessory roofcurb mountinginstructions if unit is to be curb mounted. Check unit nameplate forsupply voltage required. Determine if adequate electrical power isavailable. Furnace may be installed on Class A, B or C roofingmaterial.

SLAB MOUNTProvide a level concrete slab that extends beyond unit cabinet atleast 6 inches [152 mm], with 4 inches [102 mm] above grade. Usea 24-inch [610 mm] gravel apron in front of outdoor air openings toprevent grass and foliage from obstructing air flow.

POSITIONINGUnit air inlets and outlets may be located in any compass directionas they are not affected by wind. Provide clearance around andabove the unit for air flow, safety, and service access. See page 6for minimum clearances.

FOR OUTDOOR INSTALLATION ONLYUnit is design certified for outdoor installation only. Do not installunit in any indoor location. Do not locate unit air inlets nearexhaust vents or other sources of contaminated air.Furnace venting as supplied with the unit must be used withoutalteration or addition. Consult your local utility BEFORE installing.Although unit is weatherproof, guard against water from higherlevel runoff and overhangs.

HANDLINGUnits are designed and crated to enable handling by any conven-tional method.FORKLIFT—Unit is shipped on a skid which allows for entry offorks. A minimum fork length of 54" [1372 mm] is required. Shorterforks will damage the base of the unit.

CAUTION: Fork extensions must be used if forks are less than54" [1372 mm].RIGGING—Units may be rigged for crane or helicopter. Attachslings and spreader bars as shown in figure below. Test lift andadjust slings accordingly until unit stays horizontal.ROLLERS—The unit base rails are heavy gauge steel, adequatefor handling on pipe rollers.

MODEL A B C D12.5 Ton [44 kW] Gas and Electric 565 [256.3] 390 [176.9] 320 [145.1] 445 [201.8]

12.5 Ton [44 kW] Electric and Electric 525 [238.1] 350 [158.8] 280 [127.0] 405 [183.7]

12.5 Ton [44 kW] Cooling Only 510 [231.3] 335 [152.0] 265 [120.2] 390 [176.9]

15 Ton [52.8 kW] Gas and Electric 585 [265.4] 410 [186.0] 340 [154.2] 465 [210.9]

15 Ton [52.8 kW] Electric and Electric 540 [244.9] 365 [165.6] 295 [133.8] 420 [190.5]

15 Ton [52.8 kW] Cooling Only 520 [235.9] 345 [156.5] 275 [124.7] 400 [181.4]

CORNER WEIGHTS (LBS.) [kg]

[ ] Designates Metric Conversions

Page 6: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

6

DIMENSIONAL DATA—RRGF-/RRCF-/RREF- 12.5 AND 15 TON[44 AND 52.8 kW]

[ ] Designates Metric Conversions

Page 7: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

7

TOP VIEW—GAS MODELSRRGF-

[ ] Designates Metric Conversions

DIMENSIONAL DATARRGF-/RRCF-/RREF-12.5 AND 15 TON[44 AND 52.8 kW]

TOP VIEW—COOLING ONLY ANDELECTRIC HEAT MODELSRRCF-/RREF-

Page 8: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

8

ACCESSORY DIMENSIONSROOFCURB (RXRK-E56)The roofcurb frames the roof openings and is designed to providea watertight connection between the unit and the roof. The curb isdesigned so that roof flashing and ducts may be installed prior toplacing unit.

The curb complies with the NationalRoofing Contractors Associationrequirements when installedas shown.

ECONOMIZER (RXRQ-FM56Z)This fully modulating economizer can introduce up to 100% of suit-able outdoor air to help satisfy cooling requirements. During theeconomizer cycle, the first stage compressor will be locked out totake advantage of free outdoor air cooling. If required, the secondstage room thermostat can cycle one compressor to maintainspace temperature. When the blower motor cycles off, the econo-mizer motor will close the low leak fresh air dampers to stop out-door air entry into the building.

Economizer is designed for use in either bottom or side ductapplications.

MANUAL FRESH AIR DAMPER(RXRF-CA56)The manual fresh air damper has a fixed damper that can beadjusted to allow 0% to 25% outside air into the unit to satisfyrequirements for minimum fresh air. Outside air enters the rainhood through cleanable filters and is regulated by an adjustabledamper mounted on a fixed panel.

RELIEF DAMPER (RXRP-E56)The relief damper is used to relieve positive building pressure. Arelief damper is normally used in conjunction with the economizeraccessory. It has a barometric type damper constructed of alu-minum with gasketed sealing edges. When the blower is off orrelief is not required, gravity forces the damper to close. Mountrelief damper in return duct on side return applications.

Note: For CSA approvedeconomizer voltage mustbe specified as follows:C—208/230 voltsD—460 voltsY—575 volts

[ ] Designates Metric Conversions

Page 9: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

9

ELECTRIC HEATER KIT

R X S E - B F 020 C CUnit SizeA = 085 C = 125, 150B = 100 D = 200

Electrical Designation

Heater Rating020 = 20 kW 060 = 60 kW030 = 30 kW 090 = 90 kW040 = 40 kW

Packaged A/C Series

B = 2nd Design Series

Auxiliary Heater Kits

Commercial—Package A/C

Accessory

Rheem

GAS CONVERSION KIT

R X R J - G P 05 R

ACCESSORY MODELNUMBER

NETWEIGHTLBS. [kg]

SHIPPINGWEIGHTLBS. [kg]

Economizer RXRQ-FM56Z 152 [68.9] 229 [103.9]

Roofcurb RXRK-E56 192 [37.1] 202 [91.6]

Manual FreshAir Damper RXRF-CA56 58 [26.3] 68 [30.8]

Relief Damper RXRP-E56 32 [14.5] 44 [20.0]

Concentric Transition RXRM-EB56 90 [40.8] 140 [63.5]

Concentric Grille RXRN-EE56 39 [17.7] 57 [25.9]

Electric Heater Kit RXSE-BF020 40 [18.1] 45 [20.4]

[ ] Designates Metric Conversions

ACCESSORY DIMENSIONSCONCENTRIC TRANSITION (RXRM-EB56)This concentric transition is designed for use with the RXRK-E56roofcurb. The center duct divider must be left out of the curb whenusing the transition accessory. The transition must be inserted intothe framed area of the curb before setting the unit. The supply

opening must be near the insulation panels on the curb (towardcondenser end of the unit). The concentric transition is fullyassembled and insulated upon shipment.

Rheem

Accessory

Rooftop

Gas Conversion Kit

Design Series

TypeP = Propane Gas Kit

(Converts Natural Unitto Propane Gas Unit)

Gas SystemR = RobertshawW = White-Rodgers

05 = 81/2-20 Ton [29.9-70.3 kW] “F” Series Rooftop200,000-400,000 BTU [58.6-117.2 kW], 0-2,000 ft. [609.6 m] U.S.200,000-350,000 BTU [58.6-102.6 kW], 0-2,000 ft. [609.6 m] Canada

06 = 81/2-20 Ton [29.9-70.3 kW] “F” Series Rooftop200,000-350,000 BTU [58.6-102.6 kW], 2,000-4,500 ft. [609.6-1371.6 m]Canada ONLY

Page 10: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

10

SUPPLY DUCTDIMENSIONS

(IN.) [mm]

RETURN DUCTDIMENSIONS

(IN.) [mm]

OVERALLDIMENSIONS

(IN.) [mm]

CFM[L/s]

THROWSUPPLY

NECK AREA(SQ. FT.) [m2]

RETURNGRILLE AREA(SQ. FT.) [m2]

PRESSURE DROP(CONCENTRIC

DUCT & GRILLE)

SIDES ENDS

MIN/MAX(FT.) [m]

MIN/MAX(FT.) [m]

78 x 27[1981.2 x 685.8]

66 x 15[1676.4 x 381.0]

831/8 x 321/8[2111.4 x 816.0]

4000[1888]

13/26[4.0/7.9]

10/20[3.0/6.1]

7.8[0.72]

6.9[0.64] .12" H2O

78 x 27[1981.2 x 685.8]

66 x 15[1676.4 x 381.0]

831/8 x 321/8[2111.4 x 816.0]

5000[2360]

16/33[4.9/10.1]

12/24[3.7/7.3]

7.8[0.72]

6.9[0.64] .24" H2O

78 x 27[1981.2 x 685.8]

66 x 15[1676.4 x 381.0]

831/8 x 321/8[2111.4 x 816.0]

6000[2832]

18/37[5.5/11.3]

14/28[4.3/8.5]

7.8[0.72]

6.9[0.64] .37" H2O

78 x 27[1981.2 x 685.8]

66 x 15[1676.4 x 381.0]

831/8 x 321/8[2111.4 x 816.0]

7000[3304]

23/47[7.0/14.3]

17/35[5.2/10.7]

7.8[0.72]

6.9[0.64] .56" H2O

78 x 27[1981.2 x 685.8]

66 x 15[1676.4 x 381.0]

831/8 x 321/8[2111.4 x 816.0]

8000[3776]

25/55[7.6/16.8]

19/40[5.8/12.2]

7.8[0.72]

6.9[0.64] .74" H2O

78 x 27[1981.2 x 685.8]

66 x 15[1676.4 x 381.0]

831/8 x 321/8[2111.4 x 816.0]

9000[4248]

26/57[7.9/17.4]

20/45[6.1/13.7]

7.8[0.72]

6.9[0.64] .82" H2O

SUPPLY & RETURN GRILLE DIMENSIONAL & PERFORMANCE DATA

To determine Supply Neck Velocity and Throw at CFM [L/s] differ-ent from those listed, please refer to chart below. Proceed verti-cally from “Flow Rate Total CFM [L/s]” to diffuser “Neck Area Sq.Ft. [m2].” At intersection of lines, read Neck Velocity FPM.

To determine Throw in each direction, use CFM [L/s] in eachdirection (not total CFM [L/s]) and refer to Throw CharacteristicsChart.

[ ] Designates Metric Conversions

ACCESSORY DIMENSIONSCONCENTRIC GRILLE (RXRN-EE56)This concentric grille is sized to be used in conjunction with theRXRM-EB56 concentric transition. The grille has aluminum frame,supply louvers and return grille.

The smaller figure represents a throw resulting in a high residualvelocity of approximately 75 FPM. Using the larger throw figurewill ensure a low residual velocity of approximately 35 FPM.

Throw values are for diffuser mounted flush on 10' [3 m] ceiling. Ifmounted on exposed duct without Ceiling Effect, the throw will bereduced 25% and pattern of discharge will be at 30° angle downfrom ceiling.

Page 11: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

11

PERFORMANCE DATACOOLING RATED AND CERTIFIED WITH ARI STANDARD 360

MODELCOOLINGCAPACITY

NET BTUH [kW]

STANDARDCFM [L/s]

EFFICIENCY

SOUNDBELS➀

EERBTUH/WATT[W/W]

IPLV

RRGF-125 146,000 [42.88] 5000 [2359.7] 9.0 [2.64] 10.0 9.0

RRCF-125 146,000 [42.88] 5000 [2359.7] 9.0 [2.64] 10.0 9.0

RREF-125 146,000 [42.88] 5000 [2359.7] 9.0 [2.64] 10.0 9.0

RRGF-150 172,000 [50.41] 6000 [2831.7] 8.5 [2.49] 9.1 9.0

RRCF-150 172,000 [50.41] 6000 [2831.7] 8.5 [2.49] 9.1 9.0

RREF-150 172,000 [50.41] 6000 [2831.7] 8.5 [2.49] 9.1 9.0

MODEL

HEATING CAPACITYTHERMAL

EFFICIENCY%

HEATRISE

°F [°C] DB

INPUTBTUH[kW]

OUTPUTBTUH[kW]

RRGF-200125 200,000[58.61]

160,000[46.89] 80 15-45

[-9.4-7.2]

RRGF-250125 250,000[73.27]

200,000[58.61] 80 25-55

[-3.9-12.8]

RRGF-250150 250,000[73.27]

200,000[58.61] 80 15-45

[-9.4-7.2]

RRGF-350150 350,000[102.57]

280,000[82.10] 80 30-60

[-1.1-15.6]➀ In accordance with ARI Standard 270. NOTE: Output capacity rated in accordance with ANSI-Z21.47.

ELECTRIC HEATING

MODELHEATING OUTPUT

BTUH [kW]1ST STAGE

HEATING OUTPUTBTUH [kW]2ND STAGE

HEATING OUTPUTBTUH [kW]

TOTAL

TEMPERATURE RISE °F [°C] @ CFM [L/s]4000

[1888]5000

[2360]6000

[2832]7000

[3304]

RREF-020125C- 34,130 [10.0] 34,130 [10.0] 68,260 [20.0] 16 [8.9] 13 [7.2] 11 [6.1] 9 [5.0]

RREF-030XXXC- 49,145 [14.4] 49,145 [14.4] 98,290 [28.8] 23 [12.8] 18 [10.0] 15 [8.3] 13 [7.2]

RREF-040XXXC- 68,260 [20.0] 68,260 [20.0] 136,520 [40.0] 32 [17.8] 25 [13.9] 21 [11.7] 18 [10.0]

RREF-060XXXC- 98,290 [28.8] 98,290 [28.8] 196,580 [57.6] 46 [25.6] 36 [20.0] 30 [16.7] 26 [14.4]

RREF-090150C- 98,290 [28.8] 196,580 [57.6] 294,870 [86.4] 68 [37.8] 55 [30.6] 46 [25.6] 39 [21.7]

RREF-020125D- 34,130 [10.0] 34,130 [10.0] 68,260 [20.0] 16 [8.9] 13 [7.2] 11 [6.1] 9 [5.0]

RREF-030XXXD- 49,145 [14.4] 49,145 [14.4] 98,290 [28.8] 23 [12.8] 18 [10.0] 15 [8.3] 13 [7.2]

RREF-040XXXD- 68,260 [20.0] 68,260 [20.0] 136,520 [40.0] 32 [17.8] 25 [13.9] 21 [11.7] 18 [10.0]

RREF-060XXXD- 98,290 [28.8] 98,290 [28.8] 196,580 [57.6] 46 [25.6] 36 [20.0] 30 [16.7] 26 [14.4]

RREF-090150D- 98,290 [28.8] 196,580 [57.6] 294,870 [86.4] 68 [37.8] 55 [30.6] 46 [25.6] 39 [21.7]

RREF-030XXXY- 49,148 [14.4] 49,148 [14.4] 98,295 [28.8] 23 [12.8] 18 [10.0] 15 [8.3] 13 [7.2]

RREF-060XXXY- 98,295 [28.8] 98,295 [28.8] 196,590 [57.6] 46 [25.6] 36 [20.0] 30 [16.7] 26 [14.4]

RREF-090XXXY- 98,295 [28.8] 196,590 [57.6] 294,885 [86.4] 68 [37.8] 55 [30.6] 46 [25.6] 39 [21.7]

NOTE: Electric heat output rated at 240 volts on “C” voltage units and 480 volts on “D” voltage units.XXX In above model designation represents “125” or “150”

HEATING TEMPERATURE RISE HEATING CORRECTION FACTOR

HEATING CORRECTION FACTOR

For correction of unit output, multiply the correction factor times the unitrating in BTU if actual supply voltage differs from rated voltage.

Blower watts not included in heater ratings. Refer to Blower Table for wattson a particular job and multiply by 3.413 to obtain BTUH [kW] adder.

[ ] Designates Metric ConversionsFor correction of unit output, multiply the correction factor times thekW rating at 600V.

FORMULA: TEMP. RISE. °F [°C] = 3160 x kWCFM [kW]

3160 = CONSTANTkW = kW RATING OF UNIT

CFM [kW] = AIR FLOW AT SPECIFIED CONDITIONS

GAS HEATING

Page 12: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

12

SELECTION PROCEDURETo select an RRCF- Cooling unit, an RREF- Cooling and Electric Heating unit or RRGF- Cooling and Gas Heating unit to meet a jobrequirement, follow this procedure, with example, using data supplied in this specification sheet.

1. DETERMINE COOLING AND HEATING REQUIREMENTS AND SPECIFIC OPERATING CONDITIONS FROM PLANS AND SPECS.

Example: *Total cooling capacity— 135,000 BTUH [39.56 kW]*Sensible cooling capacity— 104,000 BTUH [30.48 kW]*Heating capacity— 195,000 BTUH [57.15 kW]*Condenser Entering Air— 95°F [35°C] DB*Evaporator Mixed Air Entering 65°F [18.3°C] WB; 78°F [25.6°C] DB*Indoor Air Flow (vertical) 4500 CFM [2124 L/s]*External Static Pressure .50 in. WG

2. SELECT UNIT TO MEET COOLING REQUIREMENTS.

Since total cooling is within the range of a nominal 12.5 ton [44 kW] unit, enter cooling performance table at 95°F [35°C] DB condenserinlet air. Interpolate between 63°F [17.2°C] and 67°F [19.4°C] to determine total capacity and power input for 65°F [18.3°C] FWB evap inletair at 5000 CFM [2360 L/s] indoor air flow (table basis):

Total Capacity = 143,150 BTUH [41.95 kW]Power Input (Compressor and Cond. Fans) = 13,900 Watts

Interpolate between 75°F [24°C] and 80°F [27°C] to determine sensible capacity at 78°F [25.6°C] FDB evaporator entering air:

Sensible Capacity = 115,000 BTUH [33.70 kW]

3. CORRECT CAPACITIES OF STEP 2 FOR ACTUAL AIR FLOW.

Select factors from airflow correction table at 4500 CFM [2124 L/s] and apply to data obtained in step 2 to obtain gross capacity:

Total capacity, 143,150 x .98 = 140,287 BTUH [41.11 kW]Sensible Capacity, 115,000 x .95 = 109,205 BTUH [32.00 kW]Power Input 13,900 x .99 = 13,761 Watts

These are Gross Capacities, not corrected for blower motor heat or power.

4. DETERMINE BLOWER SPEED AND WATTS TO MEET SYSTEM DESIGN.

Enter Indoor Blower performance table at 4500 CFM [2124 L/s]. Total ESP (external static pressure) per the spec of .50 in. includes the sys-tem duct and grilles. Add from the table “Component Air Resistance,” .065 for wet coil, .14 for vertical air flow, for a total selection static pres-sure of .705 inches of water, and determine:

RPM = 640WATTS = 1,020DRIVE = K (standard 2 H.P. motor)

5. CALCULATE INDOOR BLOWER BTUH HEAT EFFECT FROM MOTOR WATTS, STEP 4.

BTUH [L/s] = 1,020 x 3.412 = 3,480

6. CALCULATE NET COOLING CAPACITIES, EQUAL TO GROSS CAPACITY, STEP 3, MINUS INDOOR BLOWER MOTOR HEAT.

Net Total Capacity = 140,287 – 3,480 = 136,807 BTUH [40.09 kW]Net Sensible Capacity = 109,205 – 3,480 = 105,725 BTUH [30.98 kW]

7. CALCULATE UNIT INPUT AND JOB EER.

Total Power Input = 13,761 (step 3) + 1,020 (step 4) = 14,781 Watts

EER = Net Total BTUH [L/s] (step 6) = 136,807 = 9.26Power Input, Watts (above) 14,781

8. SELECT UNIT HEATING CAPACITY.

From Physical Data Table read that gas heating output (input rating x efficiency) is:

Heating Capacity = 200,000 BTUH [58.61 kW]

*NOTE: These operating conditions are typical of a commercial application in a 95°F [35°C]/79°F [26.1°C] design area with indoor design of 76°F [24.4°C]DB and 50% RH and 10% ventilation air, with the unit roof mounted and centered on the zone it conditions by ducts.

[ ] Designates Metric Conversions

Page 13: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

13

COOLING PERFORMANCE DATA—5000 CFM [2360 L/s]

COOLING PERFORMANCE DATA—6000 CFM [2832 L/s]

AIRFLOW CORRECTION FACTORS12.5 TON [44 kW]

AIRFLOW CORRECTION FACTORS15 TON [52.8 kW]

NOTES: 1. Total and sensible capacity is gross, with no deduction for indoor blower motor heat.2. Power input is gross, which does not include indoor blower motor.3. Interpolation is permissible, do not extrapolate.

ROOFTOP UNIT RRGF/RRCF/RREF—12.5 TON [44 kW]

POWERINPUT

kW

EVAPLEAVINGAIR WB°F [°C]

CONDINLET

AIR DB°F [°C]

EVAPINLET

AIR WB°F [°C]

EVAPORATOR ENTERING AIR DB—°F [°C]TOTAL

CAPACITYMBH [kW]

70 [21] 75 [24] 80 [27] 85 [29] 90 [32] 95 [35]

11.511.912.312.412.8

48.4 [9.1]52.5 [11.4]56.5 [13.6]60.8 [16.0]65.1 [18.4]

75[23.9]

59 [15.0]63 [17.2]67 [19.4]71 [21.7]75 [23.9]

106.4 [31.2]88.1 [25.8]73.9 [21.7]

0.0 [0.0]0.0 [0.0]

141.8 [41.6]153.8 [45.1]167.1 [50.0]177.9 [52.1]190.0 [55.7]

130.4 [38.2]112.0 [32.8]

97.8 [28.7]75.4 [22.1]57.0 [16.7]

139.9 [41.0]136.1 [39.9]121.9 [35.7]

99.3 [29.1]81.0 [23.7]

139.9 [41.0]151.8 [44.5]145.9 [42.8]123.4 [36.2]105.0 [30.8]

139.9 [41.0]151.8 [44.5]164.8 [48.3]147.4 [43.2]129.0 [37.8]

139.9 [41.0]151.8 [44.5]164.8 [48.3]171.3 [50.2]153.0 [44.8]

SENSIBLE CAPACITY

MBH [kW] MBH [kW] MBH [kW] MBH [kW] MBH [kW] MBH [kW]

12.412.713.113.413.7

49.1 [9.5]53.0 [11.7]57.0 [13.9]61.3 [16.3]65.5 [18.6]

85[29.4]

59 [15.0]63 [17.2]67 [19.4]71 [21.7]75 [23.9]

102.1 [30.0]83.6 [25.0]69.5 [20.4]

0.0 [0.0]0.0 [0.0]

134.2 [39.3]146.3 [42.9]159.6 [46.8]170.3 [49.9]182.4 [53.5]

126.0 [36.9]107.7 [31.6]

93.5 [27.4]71.0 [20.8]52.6 [15.4]

132.4 [38.8]131.7 [38.6]117.5 [34.4]

95.0 [27.8]76.6 [22.5]

132.4 [38.8]144.4 [42.3]141.4 [41.4]119.0 [34.9]100.7 [29.5]

132.4 [38.8]144.4 [42.3]157.4 [46.1]142.9 [41.9]124.6 [36.5]

132.4 [38.8]144.4 [42.3]157.4 [46.1]167.0 [48.9]148.6 [43.6]

14.314.615.015.315.6

50.7 [10.4]54.6 [12.6]58.5 [14.7]62.6 [17.0]66.7 [19.3]

105[40.6]

59 [15.0]63 [17.2]67 [19.4]71 [21.7]75 [23.9]

93.4 [27.4]75.7 [22.2]62.7 [18.4]

0.0 [0.0]0.0 [0.0]

113.3 [33.2]125.4 [36.8]138.6 [40.6]149.4 [43.8]161.5 [47.3]

111.7 [32.7]99.6 [29.2]86.6 [25.4]64.1 [18.8]46.4 [13.6]

111.7 [32.7]123.7 [36.3]110.6 [32.4]

88.2 [25.9]70.4 [20.6]

111.7 [32.7]123.7 [36.3]134.6 [39.5]112.1 [32.9]

94.4 [27.7]

111.7 [32.7]123.7 [36.3]136.7 [40.1]136.1 [39.9]118.3 [34.7]

111.7 [32.7]123.7 [36.3]136.7 [40.1]147.4 [43.2]142.4 [41.7]

13.313.714.114.314.7

49.9 [9.9]53.8 [12.1]57.7 [14.3]61.9 [16.6]66.1 [18.9]

95[35]

59 [15.0]63 [17.2]67 [19.4]71 [21.7]75 [23.9]

99.7 [29.2]81.1 [23.8]66.6 [20.0]

0.0 [0.0]0.0 [0.0]

124.4 [36.5]136.5 [40.0]149.8 [43.9]160.5 [47.0]172.6 [50.6]

122.7 [36.0]105.2 [30.8]

90.6 [26.6]68.0 [19.9]49.5 [14.5]

122.7 [36.0]129.1 [37.8]114.6 [33.6]

92.1 [27.0]73.6 [21.6]

122.7 [36.0]134.7 [39.5]138.5 [40.6]116.1 [34.0]

97.5 [28.6]

122.7 [36.0]134.7 [39.5]147.7 [43.3]140.0 [41.0]121.5 [35.6]

122.7 [36.0]134.7 [39.5]147.7 [43.3]158.4 [46.4]145.6 [42.7]

15.215.615.916.116.5

51.6 [10.9]55.4 [13.0]59.2 [15.1]63.3 [17.4]67.4 [19.7]

115[46.1]

59 [15.0]63 [17.2]67 [19.4]71 [21.7]75 [23.9]

80.1 [23.5]64.7 [19.0]55.2 [16.2]

0.0 [0.0]0.0 [0.0]

101.7 [29.8]113.8 [33.4]127.1 [37.3]137.8 [40.4]149.9 [43.9]

100.4 [29.4]88.2 [25.9]79.1 [23.2]56.6 [16.6]40.8 [12.0]

100.4 [29.4]112.3 [32.9]103.1 [30.2]

80.6 [23.6]64.8 [19.0]

100.4 [29.4]112.3 [32.9]125.4 [36.8]104.6 [30.7]

88.8 [26.0]

100.4 [29.4]112.3 [32.9]125.4 [36.8]128.7 [37.7]112.8 [33.1]

100.4 [29.4]112.3 [32.9]125.4 [36.8]136.0 [32.5]136.8 [40.1]

ROOFTOP UNIT RRGF/RRCF/RREF—15 TON [52.8 kW]

POWERINPUT

kW

EVAPLEAVINGAIR WB°F [°C]

CONDINLET

AIR DB°F [°C]

EVAPINLET

AIR WB°F [°C]

EVAPORATOR ENTERING AIR DB—°F [°C]TOTAL

CAPACITYMBH [kW]

70 [21] 75 [24] 80 [27] 85 [29] 90 [32] 95 [35]

14.114.615.315.916.5

48.5 [9.2]52.4 [11.3]56.3 [13.5]60.6 [15.9]64.8 [18.2]

75[23.9]

59 [15.0]63 [17.2]67 [19.4]71 [21.7]75 [23.9]

126.7 [37.1]107.3 [31.5]

92.6 [27.1]0.0 [0.0]0.0 [0.0]

169.5 [49.7]185.7 [54.4]203.7 [59.7]218.0 [63.9]234.1 [68.6]

156.5 [45.9]137.1 [40.2]122.3 [35.8]

98.3 [28.8]79.0 [23.2]

169.6 [49.7]166.8 [48.9]152.1 [44.6]128.1 [37.5]108.7 [31.9]

169.6 [49.7]185.7 [54.4]181.8 [53.3]157.8 [46.3]138.6 [40.6]

169.6 [49.7]185.7 [54.4]203.7 [59.7]158.3 [46.4]168.3 [49.3]

169.6 [49.7]185.7 [54.4]203.7 [59.7]217.4 [63.7]198.0 [58.0]

SENSIBLE CAPACITY

MBH [kW] MBH [kW] MBH [kW] MBH [kW] MBH [kW] MBH [kW]

15.115.716.417.017.6

49.1 [9.5]53.0 [11.7]56.9 [13.8]61.1 [16.2]65.3 [18.5]

85[29.4]

59 [15.0]63 [17.2]67 [19.4]71 [21.7]75 [23.9]

121.1 [35.5]101.8 [29.8]

87.0 [25.5]0.0 [0.0]0.0 [0.0]

159.9 [46.9]176.0 [51.6]194.0 [56.9]208.3 [61.1]224.5 [65.8]

150.9 [44.2]131.5 [38.5]116.7 [34.2]

92.8 [27.2]73.5 [21.5]

160.8 [47.1]161.3 [47.3]146.5 [42.9]122.6 [35.9]103.2 [30.2]

159.9 [46.9]176.0 [51.6]176.3 [51.7]152.4 [44.7]133.0 [40.0]

159.9 [46.9]176.0 [51.6]194.0 [56.9]182.1 [53.4]162.7 [47.7]

159.9 [46.9]176.0 [51.6]194.0 [56.9]208.3 [61.1]192.5 [56.4]

17.317.918.619.219.8

51.0 [10.6]54.7 [12.6]58.5 [14.7]62.5 [16.9]66.6 [19.2]

105[40.6]

59 [15.0]63 [17.2]67 [19.4]71 [21.7]75 [23.9]

107.4 [31.5]88.9 [26.1]75.8 [22.2]

0.0 [0.0]0.0 [0.0]

132.3 [38.8]148.4 [43.5]166.4 [48.8]180.7 [53.0]196.9 [57.7]

132.3 [38.8]118.7 [34.8]105.6 [31.0]

81.6 [23.9]63.1 [18.5]

132.3 [38.8]148.4 [43.5]135.3 [39.7]111.4 [32.7]

92.9 [27.2]

132.3 [38.8]148.4 [43.5]165.2 [48.4]141.2 [41.4]122.6 [35.9]

132.3 [38.8]148.4 [43.5]166.4 [48.8]170.9 [50.1]152.4 [44.7]

132.3 [38.8]148.4 [43.5]166.4 [48.8]180.7 [53.0]182.2 [53.4]

16.216.817.518.118.7

50.0 [10.0]53.8 [12.1]57.6 [14.2]61.8 [16.6]65.9 [18.8]

95[35]

59 [15.0]63 [17.2]67 [19.4]71 [21.7]75 [23.9]

116.3 [34.1]96.8 [28.4]81.6 [23.9]

0.0 [0.0]0.0 [0.0]

146.6 [43.0]162.7 [47.7]180.7 [53.0]195.0 [52.0]211.1 [61.9]

146.2 [42.9]126.5 [37.1]111.4 [32.7]

87.4 [25.6]67.8 [19.9]

146.6 [43.0]156.3 [45.8]141.1 [41.4]117.1 [34.3]

97.6 [28.6]

146.6 [43.0]162.7 [47.7]170.8 [50.1]146.9 [43.1]127.3 [37.3]

146.6 [43.0]162.7 [47.7]180.7 [53.0]176.6 [51.8]147.3 [43.2]

146.6 [43.0]162.7 [47.7]180.7 [53.0]195.0 [57.2]186.8 [54.8]

18.419.019.720.320.8

51.8 [11.0]55.5 [13.1]59.1 [15.1]63.1 [17.3]67.1 [19.5]

115[46.1]

59 [15.0]63 [17.2]67 [19.4]71 [21.7]75 [23.9]

92.0 [27.0]76.4 [22.4]69.4 [20.3]

0.0 [0.0]0.0 [0.0]

119.7 [35.1]136.0 [39.9]154.0 [45.1]168.3 [49.3]184.4 [54.0]

119.8 [35.1]106.2 [31.1]

99.1 [29.0]75.1 [22.0]59.6 [17.5]

119.8 [35.1]136.0 [39.9]128.9 [37.8]104.9 [30.7]

89.4 [26.2]

119.8 [35.1]136.0 [39.9]154.0 [45.1]134.6 [39.5]119.2 [34.9]

119.8 [35.1]136.0 [39.9]154.0 [45.1]164.4 [48.2]148.9 [43.6]

119.8 [35.1]136.0 [39.9]151.1 [44.3]168.3 [49.3]178.7 [52.4]

CFM[L/s]—ACTUAL

4000[1888]

4500[2124]

5500[2596]

6000[2832]

TOTAL MBH 0.95 0.98 1.02 1.05

SENSIBLE MBH 0.90 0.95 1.05 1.10

POWER KW 0.98 0.99 1.01 1.02

5000[2360]

1.00

1.00

1.00

CFM[L/s]—ACTUAL

4800[2265]

5400[2549]

6000[2832]

6600[3155]

TOTAL MBH 0.95 0.98 1.00 1.02

SENSIBLE MBH 0.90 0.95 1.00 1.05

POWER KW 0.98 0.99 1.00 1.01

7200[3398]

1.05

1.10

1.02

[ ] Designates Metric Conversions

NOTES: 1. Multiply correction factor times gross performance data. 2. Resulting sensible capacity cannot exceed total capacity.

Page 14: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

14

NO

TE

S: 1

. Bel

ow h

eavy

line

req

uire

s op

tiona

l mot

or d

rive.

2. P

erfo

rman

ce s

how

n w

ith d

ry c

oil a

nd s

tand

ard

2" [5

0.8

mm

] filt

ers

in th

esi

deflo

w c

onfig

urat

ion.

3. S

tand

ard

CF

M [L

/s] @

.075

LB

. [kg

]/FT.

[m]3 .

IND

OO

R B

LOW

ER

PE

RFO

RM

AN

CE

DA

TAR

RG

F—12

.5 T

ON

[44

kW] G

AS

HE

AT

NO

TE

:Add

com

pone

nt r

esis

tanc

e to

duc

t res

ista

nce

to d

eter

min

e to

tal s

tatic

pre

ssur

e.

NO

TE

: Add

com

pone

nt r

esis

tanc

e to

duc

t res

ista

nce

to d

eter

min

e to

tal s

tatic

pre

ssur

e.

CO

MP

ON

EN

T A

IR R

ES

ISTA

NC

E R

RG

F—

12.5

TO

N [4

4 kW

]IN

DO

OR

BLO

WE

R D

RIV

E S

PE

CS

RR

GF

—12

.5 T

ON

[44

kW]

CO

MP

ON

EN

TA

IRR

ES

ISTA

NC

E R

RC

F/R

RE

F—

12.5

TO

N [4

4 kW

]IN

DO

OR

BLO

WE

R D

RIV

E S

PE

CS

R

RC

F/R

RE

F—

12.5

TO

N [4

4 kW

]

IND

OO

R B

LOW

ER

PE

RFO

RM

AN

CE

DA

TA R

RC

F/R

RE

F—12

.5 T

ON

[44

kW] C

OO

LIN

G O

NLY

& E

LEC

TRIC

HE

AT

KL

RPM

WRP

MW

RPM

WRP

MW

——

605

650

620

750

635

820

600

780

625

900

640

1020

653

1160

630

1240

645

1380

660

1560

674

1700

660

1850

675

1980

690

2140

713

2260

702

2460

715

2620

738

2740

759

2850

RPM

WRP

MW

RPM

W73

914

2576

215

8078

917

2076

319

0078

620

6081

121

8079

723

8081

825

0083

626

4082

829

0084

730

35—

——

——

——

E.S

.P.—

INC

HE

S O

F W

AT

ER

[kP

a]

RPM

WRP

MW

RPM

WRP

MW

650

900

668

1020

690

1120

715

1320

668

1360

692

1480

713

1600

738

1760

RPM

WRP

MW

RPM

WRP

MW

700

1860

720

1980

745

2100

770

2260

736

2380

759

2510

781

2640

806

2760

779

2980

804

3060

829

3220

846

3340

4000

[188

8]—

——

——

——

—45

00 [2

124]

——

——

——

590

660

5000

[236

0]—

——

695

980

615

1100

5500

[259

6]60

012

8561

514

0063

015

4064

517

0060

00 [2

832]

630

1880

655

2040

670

2160

685

2300

STD. K

2 H.

P.ST

D. K3

H.P.

DRIV

EPK

G.ST

D. A

IRCF

M [L

/s]

.5 [0

.12]

.6 [0

.15]

.7 [0

.17]

.8 [0

.20]

1.3

[0.3

2]1.

4 [0

.35]

1.5

[0.3

7].1

[0.0

2].2

[0.0

5].3

[0.0

7].4

[0.1

0].9

[0.2

2]1.

0 [0

.25]

1.1

[0.2

7]1.

2 [0

.30]

KL

.5 [0

.12]

.6 [0

.15]

.7 [0

.17]

.8 [0

.20]

RPM

WRP

MW

RPM

WRP

MW

480

1110

510

1190

540

1280

565

1360

505

1320

530

1410

555

1500

580

1570

525

1540

550

1640

575

1730

595

1800

545

1785

570

1885

595

1980

615

2045

575

2060

600

2200

620

2230

640

2330

1.3

[0.3

2]1.

4 [0

.35]

1.5

[0.3

7]1.

6 [0

.40]

RPM

WRP

MW

RPM

WRP

MW

675

1680

695

1725

710

1770

730

1840

685

1870

705

1950

720

2035

STD.

AIR

CFM

[L/s

]

E.S

.P.—

INC

HE

S O

F W

AT

ER

[kP

a]

740

2100

700

2160

720

2260

740

2360

755

2440

715

2505

735

2590

755

2690

770

2780

740

2920

760

3060

——

——

.1 [0

.02]

.2 [0

.05]

.3 [0

.07]

.4 [0

.10]

.9 [0

.22]

1.0

[0.2

5]1.

1 [0

.27]

1.2

[0.3

0]

RPM

WRP

MW

RPM

WRP

MW

590

1420

605

1470

630

1540

655

1610

600

1650

620

1650

640

1705

665

1790

RPM

WRP

MW

RPM

WRP

MW

620

1820

635

1880

655

1960

680

2060

635

2075

655

2170

675

2280

695

2395

655

2430

675

2530

695

2650

715

2780

4000

[188

8]—

——

——

——

—45

00 [2

124]

——

——

——

475

1225

5000

[236

0]—

——

—47

536

050

014

5055

00 [2

596]

——

470

1490

490

1590

520

1690

6000

[283

2]45

016

6050

017

4052

518

5055

019

40

DRIV

EPK

G.

STD. K

2 H.

P.ST

D. K3

H.P.

RESI

STAN

CE—

INCH

ES O

F W

ATER

[kPa

]

Botto

m S

uppl

y an

d Re

turn

.100

Conc

entri

c Gr

ille

and

Tran

sitio

n.1

20

COM

PONE

NTST

ANDA

RD IN

DOOR

AIR

FLOW

—CF

M [L

/s]

4000

[188

8]45

00 [2

124]

.180

.140

.185

.240

5000

[236

0]55

00 [2

596]

.310

.235

6000

[283

2]

.370

.300

.073

.082

Wet

Coi

l.0

58.0

93.0

65

Econ

omize

r RA

Dam

per O

pen

.065

.037

.081

.092

.051

MOT

ORSH

EAVE

O.D.

IN. [

mm

]

DRIV

EPA

CKAG

E

BLOW

ERPU

LLEY

O.D.

IN. [

mm

]

BELT

SIZE

TYPE

NO. T

URNS

OPEN

50

12

34

595

93/4

[248

]B-

6245

/32

[106

]K

(Sta

ndar

d)—

670

645

630

615

BLOW

ER R

PM

700

93/4

[248

]B-

6043

/4[1

21]

L (O

ptio

nal)

—85

482

177

874

0

6 668

570

4. M

otor

effi

cien

cy =

80%

5. B

HP

= W

atts

x M

otor

Effi

cien

cy74

6

CO

DE

S:

BH

P=

Bra

ke H

orse

pow

erC

FM

[L/s

]= C

ubic

Fee

t per

min

utes

; air

quan

tity

RP

M=

Rev

olut

ions

per

min

ute;

fan

spee

dW

=W

atts

; mot

or e

lect

rical

inpu

t

RESI

STAN

CE—

INCH

ES O

F W

ATER

[kPa

]

Botto

m S

uppl

y An

d Re

turn

.050

Conc

entri

c Gr

ille

And

Tran

sitio

n.1

20

COM

PONE

NTST

ANDA

RD IN

DOOR

AIR

FLOW

—CF

M [L

/s]

4000

[188

8]45

00 [2

124]

.180

.075

.100

.240

5000

[236

0]55

00 [2

596]

.310

.125

6000

[283

2]

.370

.150

.073

.082

Wet

Coi

l.0

58.0

93.0

65Ec

onom

izer R

A Da

mpe

r Ope

n.0

65.0

37.0

81.0

92.0

61

Resi

stan

ceHe

ater

20-

30 k

WKi

t 40-

60 k

W

.20

.16

.22

.24

.18

.35

.40

.25

.45

.30

MOT

ORSH

EAVE

O.D.

IN. [

mm

]

DRIV

EPA

CKAG

E

BLOW

ERPU

LLEY

O.D.

IN. [

mm

]

BELT

SIZE

TYPE

NO. T

URNS

OPE

N5

01

23

4

490

113 /

4[2

98]

B-44

45/3

2[1

06]

K (S

tand

ard)

—61

058

055

052

0BL

OWER

RPM

650

103 /

4[2

73]

B-45

43/4

[121

]L

(Opt

iona

l)—

770

740

710

680

6 620

460

1725

3 [2

237]

1725

2 [1

491]

MOT

ORRP

MM

OTOR

HP [W

]

Fact

ory

setti

ngs

are

shad

ed.

Fact

ory

setti

ngs

are

shad

ed.

[]

Des

ign

ates

Met

ric

Co

nver

sio

ns

Page 15: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

15

MOT

ORSH

EAVE

O.D.

IN. [

mm

]

DRIV

EPA

CKAG

E

BLOW

ERPU

LLEY

O.D.

IN. [

mm

]

BELT

SIZE

TYPE

NO. T

URNS

OPEN

50

12

34

625

103 /

4[2

73]

B-64

43/4

[121

]K

(Sta

ndar

d)80

076

573

069

566

0BL

OWER

RPM

885

93/4

[248

]B-

606

[152

]L

(Opt

iona

l)—

—98

595

592

0

6 835

510

KL

RPM

WRP

MW

RPM

WRP

MW

——

580

1120

608

1200

630

1280

630

1740

649

1940

672

2060

692

2200

665

2240

683

2390

706

2500

730

2600

700

2720

723

2815

741

2920

757

3080

740

3200

752

3280

770

3360

793

3480

RPM

WRP

MW

RPM

W75

019

4077

120

8079

622

60

800

2800

819

3000

836

3150

825

3280

844

3340

840

3400

853

3640

870

3760

886

3900

881

4160

896

4300

911

4420

E.S

.P.—

INC

HE

S O

F W

AT

ER

[kP

a]

RPM

WRP

MW

RPM

WRP

MW

655

1480

677

1580

701

1740

730

1860

717

2300

739

2420

756

2510

775

2640

RPM

WRP

MW

RPM

WRP

MW

746

2720

762

2840

783

3080

805

3120

774

3140

797

3280

815

3380

835

3500

811

3540

829

3650

848

3800

864

4000

4800

[226

5]—

——

——

——

5600

[264

3]—

——

——

—60

816

0060

00 [2

832]

——

——

625

1980

645

2100

6400

[302

0]—

—64

223

6066

325

4068

126

2068

00 [3

209]

665

2760

680

2880

701

2960

722

3100

STD. K

3 H.

P.

STD. K

5 H.

P.

DRIV

EPK

G.ST

D. A

IRCF

M [L

/s]

.5 [0

.12]

.6 [0

.15]

.7 [0

.17]

.8 [0

.20]

1.3

[0.3

2]1.

4 [0

.35]

1.5

[0.3

7].1

[0.0

2].2

[0.0

5].3

[0.0

7].4

[0.1

0].9

[0.2

2]1.

0 [0

.25]

1.1

[0.2

7]1.

2 [0

.30]

592

1180

615

1400

640

1580

663

1740

773

2340

796

2520

815

2630

685

1860

708

2020

732

2120

752

2240

5200

[245

4]—

——

——

——

775

3640

791

3780

813

3880

827

4000

909

4700

923

4840

939

4960

846

4160

863

4260

879

4400

894

4600

7200

[339

8]68

732

6072

233

8074

034

6075

835

40

IND

OO

R B

LOW

ER

PE

RFO

RM

AN

CE

DA

TAR

RG

F—15

TO

N [5

2.8

kW] G

AS

HE

AT

NO

TE

:Add

com

pone

nt r

esis

tanc

e to

duc

t res

ista

nce

to d

eter

min

e to

tal s

tatic

pre

ssur

e.

NO

TE

: Add

com

pone

nt r

esis

tanc

e to

duc

t res

ista

nce

to d

eter

min

e to

tal s

tatic

pre

ssur

e.

CO

MP

ON

EN

T A

IR R

ES

ISTA

NC

E R

RG

F—

15 T

ON

[52.

8 kW

]IN

DO

OR

BLO

WE

R D

RIV

E S

PE

CS

RR

GF

—15

TO

N [5

2.8

kW]

CO

MP

ON

EN

TA

IRR

ES

ISTA

NC

E R

RC

F/R

RE

F—

15 T

ON

[52.

8 kW

]IN

DO

OR

BLO

WE

R D

RIV

E S

PE

CS

R

RC

F/R

RE

F—

15 T

ON

[52.

8 kW

]

IND

OO

R B

LOW

ER

PE

RFO

RM

AN

CE

DA

TA R

RC

F/R

RE

F—15

TO

N [5

2.8

kW] C

OO

LIN

G O

NLY

& E

LEC

TRIC

HE

AT

KL

.5 [0

.12]

.6 [0

.15]

.7 [0

.17]

.8 [0

.20]

RPM

WRP

MW

RPM

WRP

MW

——

——

——

585

1530

——

——

580

1670

600

1730

580

1990

595

2060

615

2130

635

2200

600

2290

615

2380

635

2480

655

2575

620

2710

640

2800

660

2900

680

3000

1.3

[0.3

2]1.

4 [0

.35]

1.5

[0.3

7]1.

6 [0

.40]

RPM

WRP

MW

RPM

WRP

MW

695

1850

710

1930

735

2140

760

2260

705

2100

725

2350

750

2490

STD.

AIR

CFM

[L/s

]

E.S

.P.—

INC

HE

S O

F W

AT

ER

[kP

a]

770

2630

735

2890

750

2990

770

3090

790

3200

750

3210

765

3300

780

3410

800

3540

765

3590

780

3710

795

3840

815

3970

.1 [0

.02]

.2 [0

.05]

.3 [0

.07]

.4 [0

.10]

.9 [0

.22]

1.0

[0.2

5]1.

1 [0

.27]

1.2

[0.3

0]

RPM

WRP

MW

RPM

WRP

MW

605

1590

625

1650

650

1710

675

1770

620

1800

640

1870

660

1940

685

2025

RPM

WRP

MW

RPM

WRP

MW

655

2290

675

2380

695

2470

725

2790

675

2670

695

2270

720

3050

735

3130

700

3110

725

3260

735

3370

750

3480

4800

[226

5]—

——

——

——

—52

00 [2

454]

——

——

——

——

6000

[283

2]—

——

——

——

—64

00 [3

020]

——

——

——

585

2200

6800

[320

9]—

—57

524

5059

025

2060

526

10

DRIV

EPK

G.

STD. K

3 H.

P.

STD. K

5 H.

P.65

530

9067

531

8069

532

8071

033

9078

540

0080

541

3082

542

6084

543

9072

535

6074

036

6075

537

7077

038

8072

00 [3

398]

585

2780

600

2850

615

2930

635

3010

——

580

1830

600

1890

620

1960

725

2580

740

2670

760

2780

780

2900

640

2030

660

2110

680

2180

700

2260

5600

[264

3]—

——

——

——

RESI

STAN

CE—

INCH

ES O

F W

ATER

[kPa

]

Botto

m S

uppl

y an

d Re

turn

.15

Conc

entri

c Gr

ille

and

Tran

sitio

n.2

2

COM

PONE

NT

STAN

DARD

INDO

OR A

IRFL

OW—

CFM

[L/s

]48

00[2

265]

5200

[245

4]

.26

.20

.24

.31

5600

[264

3]60

00[2

832]

.37

.30

6400

[302

0]

.44

.34

.081

.093

Wet

Coi

l.0

69.0

98.0

76

Econ

omize

r RA

Dam

per O

pen

.072

.044

.092

.103

.052

.111

.124

6800

[320

9]

.52

.39

7200

[339

8]

.61

.43

.105

.117

RESI

STAN

CE—

INCH

ES O

F W

ATER

[kPa

]

Botto

m S

uppl

y An

d Re

turn

.100

Conc

entri

c Gr

ille

And

Tran

sitio

n.2

2

COM

PONE

NT

STAN

DARD

INDO

OR A

IRFL

OW—

CFM

[L/s

]48

00[2

265]

5200

[245

4]

.26

.115

.130

.31

5600

[264

3]60

00[2

832]

.37

.150

6400

[302

0]

.44

.175

.081

.093

Wet

Coi

l.0

69.0

98.0

76Ec

onom

izer R

A Da

mpe

r Ope

n.0

72.0

44.0

92.1

03.0

52

Resi

stan

ce 3

0 kW

Heat

er 4

0-60

kW

Kit 9

0 kW

.230

.200

.250

.275

.215

.675

.800

.550

.850

.600

.111

.124

6800

[320

9]

.52

.205

.305

.350

.920

7200

[339

8]

1.00

.61

.250

.105

.117

.410

.350

.450

.495

.380

.550

.600

MOT

ORSH

EAVE

O.D.

IN. [

mm

]

DRIV

EPA

CKAG

E

BLOW

ERPU

LLEY

O.D.

IN. [

mm

]

BELT

SIZE

TYPE

NO. T

URNS

OPE

N5

01

23

4

600

113 /

4[2

98]

B-43

43/4

[121

]K

(Sta

ndar

d)—

710

685

655

625

BLOW

ER R

PM

735

113 /

4[2

98]

B-42

6[1

52]

L (O

ptio

nal)

875

845

815

785

760

6 710

575

Fact

ory

setti

ngs

are

shad

ed.

Fact

ory

setti

ngs

are

shad

ed.

[]

Des

ign

ates

Met

ric

Co

nver

sio

ns

NO

TE

S: 1

. Bel

ow h

eavy

line

req

uire

s op

tiona

l mot

or d

rive.

2. P

erfo

rman

ce s

how

n w

ith d

ry c

oil a

nd s

tand

ard

2" [5

0.8

mm

] filt

ers

in th

esi

deflo

w c

onfig

urat

ion.

3. S

tand

ard

CF

M [L

/s] @

.075

LB

. [kg

]/FT.

[m]3 .

4. M

otor

effi

cien

cy =

80%

5. B

HP

= W

atts

x M

otor

Effi

cien

cy74

6

CO

DE

S:

BH

P=

Bra

ke H

orse

pow

erC

FM

[L/s

] = C

ubic

Fee

t per

min

utes

; air

quan

tity

RP

M=

Rev

olut

ions

per

min

ute;

fan

spee

dW

= W

atts

; mot

or e

lect

rical

inpu

t

Page 16: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

16

ELECTRICAL DATAGAS HEAT AND COOLING ONLY MODELS—RRGF-/RRCF-

MODEL SIZE 12.5 TON [44 kW] 15 TON [52.8 kW]POWER—VOLTS 3 PH-60 HERTZ 208/230 460 575 208/230 460 575COMPRESSOR #1 #1 #1 #1 #1 #1RLA Each 30/27 14 12.4 38/34.5 17.3 14.4LRA Each 183 91.1 73.3 193 96.5 77.2CONDENSER FAN MOTOR (NUMBER) (3) (3) (3) (3) (3) (3)

2.2 1.3 .8 2.2 1.3 .8

INDOOR BLOWER MOTOR (NUMBER) (1) (1) (1) (1) (1) (1)

H.P.1.2 .6 1.2 1.2 .6 1.23 3 3 5 5 5

FLA7.5/6.8 3.4 2.6 10.6/9.6 4.8 3.7

10.6/9.6 4.8 3.7 10.7/15.2 7.6 6.1

UNIT TOTALFLA

61/55 29 23 78/72 36 2864/58 31 24 84/77 39 30

UNIT TOTALLRA

344 172 133.4 402 202 159.9352 176 142.0 434 217 174.2

MIN. CIRCUITAMPACITY

69/62 33 26 88/80 40 3272/65 34 28 94/86 43 34

MAX. FUSE OR HACR BREAKERSIZE-AMPACITY 80 45 35 110 50 45

STD.

STD.

STD.

STD.

STD.

OPT.

OPT.

OPT.

OPT.

OPT.

FLA (Each)

#217/15

90

#28

45

#25.536

#223/21130

#21065

#27.050

DRAFT MOTOR* (NUMBER) (1) (1) (1) (1) (1) (1)FLA (Each) 1.2 .6 1.2 1.2 .6 1.2

*Gas heat models ONLY

ELECTRIC HEAT/ELECTRIC COOL MODELS—RREF-*MODEL SIZE 12.5 TON [44 kW]

HEATER SIZENOMINAL kW 20 30 40 60

POWER VOLTS3 PH-60 HZ 208/230 460 208/230 460 575 208/230 460 208/230 460 575

COMPRESSOR(NUMBER) 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

RLA Each 30/27 17/15 14 8 30/27 17/5 14 8 12.4 5.5 30/27 17/15 14 8 30/27 17/15 14 8 12.4 5.5LRA Each 183 90 91.1 45 183 90 91.1 45 73.3 36 183 90 91.1 45 183 90 91.1 45 73.3 36CONDENSER FANMOTOR (NUMBER) 3 3 3 3 3 3 3 3 3 3

FLA 2.2 1.3 2.2 1.3 .8 2.2 1.3 2.2 1.3 .8INDOOR BLOWERMOTOR (NUMBER) 1 1 1 1 1 1 1 1 1 1

H.P.STD. 2 2 2 2 2 2 2 2 2 2OPT. 3 3 3 3 3 3 3 3 3 3

HEATER FLA 42/48 24 60/70 35 27.7 83/96 48 120/139 70 55.5

MIN. CIRCUITAMPACITY

STD. 69/69 34 84/96 48 38 113/129 64 159/182 92 73OPT. 72/72 36 88/100 50 39 117/132 66 163/186 94 74

MAX. FUSE ORHACR BRKR.

STD. 90/90 45 90/100 50 40 125/150 70 175/200 100 80OPT. 90/90 45 100/100 50 40 125/150 70 175/200 100 80

FLASTD. 7.5/6.8 3.4 7.5/6.8 3.4 2.6 7.5/6.8 3.4 7.5/6.8 3.4 2.6OPT. 10.6/9.6 4.8 10.6/9.6 4.8 3.7 10.6/9.6 4.8 10.6/9.6 4.8 3.7

➀ Field wiring must comply with the National Electric Code (Canadian Electrical Code in Canada) and any local ordinance that may apply.➁ 575 volt models are not U.L. Listed.* Also applicable for RRCF with RXSE-BF electric heater kit installed. [ ] Designates Metric Conversions

MODEL SIZE 15 TON [52.8 kW]HEATER SIZENOMINAL kW 30 60

POWER VOLTS3 PH-60 HZ 208/230 460 575 208/230 460 208/230 460 575 208/230 460

COMPRESSOR(NUMBER) 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

RLA Each 38/34.5 23/21 17.3 10 14.4 7.0 38/34.5 23/21 17.3 10 38/34.5 23/21 17.3 10 14.4 7.0 38/34.5 23/21 17.3 10LRA Each 193 130 96.5 65 77.2 50 193 130 96.5 65 193 130 96.5 65 77.2 50 193 130 96.5 65CONDENSER FANMOTOR (NUMBER) 3 3 3 3 3 3 3 3 3 3

FLA 2.2 1.3 .8 2.2 1.3 2.2 1.3 .8 2.2 1.3INDOOR BLOWERMOTOR (NUMBER) 1 1 1 1 1 1 1 1 1 1

H.P.STD. 3 3 3 3 3 3 3 3 3 3OPT. 5 5 5 5 5 5 5 5 5 5

HEATER FLA 60/70 35 27.7 83/96 48 120/139 70 55.5 180/208 104

MIN. CIRCUITAMPACITY

STD. 88/100 50 39 117/132 66 163/186 94 74 238/272 136OPT. 96/107 53 42 125/139 70 171/193 97 77 246/279 140

MAX. FUSE ORHACR BRKR.

STD. 125/110 50 40 125/150 70 175/200 100 80 250/300 150OPT. 125/125 60 45 150/150 70 175/200 100 80 250/300 150

FLASTD. 10.6/9.6 4.8 3.7 10.6/9.6 4.8 10.6/9.6 4.8 3.7 10.6/9.6 4.8OPT. 16.7/15.2 7.6 6.1 16.7/15.2 7.6 16.7/15.2 7.6 6.1 16.7/15.2 7.6

575

1 2

14.4 7.077.2 50

3

.8

1

35

83.2109117110125

3.76.1

9040

Page 17: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

17

TYPICAL WIRING SCHEMATICS

COMPONENT CODEBC BLOWER CONTACTOR HC HEATER CONTROLLERBR BLOWER RELAY HPC HIGH PRESSURE CONTROLCC COMPRESSOR CONTACTOR IBM INDOOR BLOWER MOTORCCH CRANKCASE HEATER J JUMPERCM COMPRESSOR MOTOR LPC LOW PRESSURE CONTROLCT CONTROL TRANSFORMER MS MIXED AIR SENSORDISC DISCONNECT SWITCH OFM OUTDOOR FAN MOTORDM DAMPER MOTOR PL PLUGEC ENTHALPY CONTROL POT POTENTIOMETERER ECONOMIZER RELAY RAFS RETURN AIR FIRESTATFC FAN MOTOR CONTACTOR RCAP RUN CAPACITORFCC FAN CYCLE CONTROL SAFS SUPPLY AIR FIRESTATFUT FUSE W/TIME DELAY TB TERMINAL BLOCKGL GROUND LUG TDC TIME DELAY CONTROLGRD GROUND

WIRING INFORMATION1. LINE VOLTAGE

FACTORY STANDARDFACTORY OPTIONFIELD INSTALLED

2. LOW VOLTAGEFACTORY STANDARDFACTORY OPTIONFIELD INSTALLED

3. REPLACEMENT WIREMUST BE THE SAME SIZE AND TYPE OFINSULATION AS ORIGINAL (105°C MIN.)

WARNINGCABINET MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.,(C.E.C.-CANADA) AND LOCAL CODES.

90-42300-02-09

WIRING SCHEMATIC12.5 AND 15 TON

[44 & 52.8 kW]RRCF/RREF

208/230, 460V AND 575V UNITS,60HZ

WIRE COLOR CODEBK — BLACK PU — PURPLEBR — BROWN RD — REDBU — BLUE WH — WHITEGR — GREEN YL — YELLOWOR — ORANGE

Page 18: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

18

TYPICAL WIRING SCHEMATICS

COMPONENT CODEBC BLOWER CONTACTOR IBM INDOOR BLOWER MOTORBR BLOWER RELAY IC IGNITION CONTROLCC COMPRESSOR CONTACTOR IDM INDUCED DRAFT MOTORCCH CRANKCASE HEATER IDR INDUCED DRAFT RELAYCM COMPRESSOR MOTOR J JUMPERCS CENTRIFUGAL SWITCH LC LIMIT CONTROLCT CONTROL TRANSFORMER LPC LOW PRESSURE CONTROLDISC DISCONNECT SWITCH MS MIXED AIR SENSORDM DAMPER MOTOR OFM OUTDOOR FAN MOTOREC ENTHALPY CONTROL PGV PILOT GAS VALVEER ECONOMIZER RELAY PL PLUGFC FAN MOTOR CONTACTOR POT POTENTIOMETERFCC FAN CYCLE CONTROL RAFS RETURN AIR FIRESTATFLMS FLAME SENSOR RC ROLLOUT CONTROLFUT FUSE W/TIME DELAY RCAP RUN CAPACITORGL GROUND LUG SAFS SUPPLY AIR FIRESTATGRD GROUND SE SPARK ELECTRODEGV GAS VALVE TB TERMINAL BLOCKHPC HIGH PRESSURE CONTROL TDC TIME DELAY CONTROL

WIRING INFORMATION1. LINE VOLTAGE

FACTORY STANDARDFACTORY OPTIONFIELD INSTALLED

2. LOW VOLTAGEFACTORY STANDARDFACTORY OPTIONFIELD INSTALLED

3. REPLACEMENT WIREMUST BE THE SAME SIZE AND TYPE OFINSULATION AS ORIGINAL (105°C MIN.)

WARNINGCABINET MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.,(C.E.C.-CANADA) AND LOCAL CODES.

90-42275-13-06

WIRING SCHEMATIC12.5 AND 15 TON [44 & 52.8 kW]

ROOFTOP RRGF208/230 AND 460V UNITS,

SINGLE VALVE—COMBINATION UNIT

NATURAL AND PROPANE GASHONEYWELL IGNITION AND

WHITE RODGERS GAS CONTROLS

WIRE COLOR CODEBK — BLACK PU — PURPLEBR — BROWN RD — REDBU — BLUE WH — WHITEGR — GREEN YL — YELLOWOR — ORANGE

Page 19: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

19

TYPICAL WIRING SCHEMATICS

COMPONENT CODEBC BLOWER CONTACTOR IC IGNITION CONTROLBR BLOWER RELAY IDM INDUCED DRAFT MOTORCC COMPRESSOR CONTACTOR IDR INDUCED DRAFT RELAYCCH CRANKCASE HEATER J JUMPERCM COMPRESSOR MOTOR LC LIMIT CONTROLCS CENTRIFUGAL SWITCH LPC LOW PRESSURE CONTROLCT CONTROL TRANSFORMER MS MIXED AIR SENSORDISC DISCONNECT SWITCH OFM OUTDOOR FAN MOTORDM DAMPER MOTOR PGV PILOT GAS VALVEEC ENTHALPY CONTROL PL PLUGER ECONOMIZER RELAY POT POTENTIOMETERFC FAN MOTOR CONTACTOR PT POWER TRANSFORMERFCC FAN CYCLE CONTROL RAFS RETURN AIR FIRESTATFLMS FLAME SENSOR RC ROLLOUT CONTROLFUT FUSE W/TIME DELAY RCAP RUN CAPACITORGL GROUND LUG SAFS SUPPLY AIR FIRESTATGRD GROUND SE SPARK ELECTRODEGV GAS VALVE TB TERMINAL BLOCKHPC HIGH PRESSURE CONTROL TDC TIME DELAY CONTROLDBM INDOOR BLOWER MOTOR

WIRING INFORMATION1. LINE VOLTAGE

FACTORY STANDARDFACTORY OPTIONFIELD INSTALLED

2. LOW VOLTAGEFACTORY STANDARDFACTORY OPTIONFIELD INSTALLED

3. REPLACEMENT WIREMUST BE THE SAME SIZE AND TYPE OFINSULATION AS ORIGINAL (105°C MIN.)

WARNINGCABINET MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.,(C.E.C.-CANADA) AND LOCAL CODES.

90-42275-18-01

WIRING SCHEMATIC12.5 AND 15 TON [44 & 52.8 kW]

ROOFTOP RRGF575 VOLT COMBINATION UNITNATURAL AND PROPANE GAS

HONEYWELL IGNITION ANDWHITE RODGERS GAS CONTROL

WIRE COLOR CODEBK — BLACK PU — PURPLEBR — BROWN RD — REDBU — BLUE WH — WHITEGR — GREEN YL — YELLOWOR — ORANGE

Page 20: Commercial Heating and Cooling RRCF- Cooling Only RREF- …pts.myrheem.com/docstore/webdocs/servicedocs/histlib/... · 1997. 12. 15. · 12.5 & 15 NOMINAL TON UNITS [44 & 52.8 kW]

GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in normal use and services within the applicableperiods stated below, in accordance with the terms of thelimited warranty.

Heat Exchanger in Gas/ElectricRooftop Unit ............................................Ten (10) Years

Heating Elements in Electric/ElectricRooftop Unit or Electric Duct Heater ............Five (5) Years

Air Conditioner Motor Compressor ..................Five (5) YearsAny Other Part................................................One (1) Year

*For complete details of the limited warranty, including appli-cable terms and conditions, see your local installer or con-tact the manufacturer for a copy.

SAMPLE SPECIFICATIONCOMBINATION HEATING ANDCOOLING ROOFTOP UNITCombination Heating and Cooling Rooftop Unit(s) shall be com-pletely factory assembled as a unitary package consisting of heat-ing section, cooling section, air handling-filtering section, andcomplete operating controls section. Unit(s) shall have flexibility ofair flow for either curb mounting with separate ducting through bot-tom or concentric ducting through bottom, or separate side by sideducting through side, with the duct air flow arrangement as shownon the plans. The entire assembly shall be U.L./C.S.A. listed ongas heating/electric cooling models, electric heating/electric cool-ing and cooling only models, with the cooling capacity A.R.I. certi-fied. Cabinet and condenser base pan shall be powder coatpainted and capable of withstanding a 1000-HR salt spray test perASTM B 117. Service access panels shall be furnished as stan-dard to allow service and inspection of all internal components.Unit(s) furnished shall be Rheem model(s).

COOLING HEATING CAPACITY—The total heating capacityshall be not less than ________ BTUH [kW] (gas input) (electricheating output) and a minimum of ________ BTUH [kW] cooling,with ________ CFM [L/s] evaporator air entering the unit at stan-dard ARI conditions.

COOLING SECTION—Two refrigerant circuits, each equippedwith a hermetic compressor, shall be furnished standard withcrankcase heaters. The refrigeration system shall be factorycharged, ready for operation, providing two stage cooling capacity(66% and 100%). Compressor protection shall include high pres-sure control and low pressure control. Evaporator coil shall havetwo full face refrigerant circuits.

CONDENSER FANS AND MOTORS—Each unit shall have three1075 RPM permanently lubricated motors fixed with direct drive,multiple blade fans. Motors shall be equipped with inherentoverload protection. Motors and fans shall be mounted on remov-able top panels for easy access. Condenser air shall dischargevertically.

[ ] Designates Metric Conversions

EVAPORATOR BLOWER AND MOTOR—The evaporator blowerassembly shall consist of a double inlet, forward curved, centrifu-gal blower with ground and polished steel shaft, coated with rustinhibitor and permanently lubricated ball bearings. The assemblyshall have a single belt drive system with fixed blower sheave andadjustable pitch motor sheave. The blower motor shall be________ hp [W], 1725 RPM, thermally protected and bolted to an adjustable motor mount. The assembly shall be capable ofmoving ________ CFM [L/s] at _________ in. of W.C. externalstatic pressure.

GAS HEATING SECTION—The gas fired heating shall be stagedat 50% and 100% capacity as controlled by a two-stage gas valve.A power venter and an electronic spark ignition shall be furnishedstandard, backed with safety features including outlet air limitswitch, centrifugal switch on the venter, motor fan-limit control anda pilot flame switch. The heat exchanger shall be constructed ofaluminized steel tubes.

ELECTRIC HEATING SECTION—The electric heating sectionshall be furnished with nickel-chromium heating elements, witheach heater element protected by an automatic reset limit thermo-stat and heat limiter for both primary and secondary overcurrent/thermal protection. Factory installed maximum size fusing shall befurnished standard.

UNIT CONFIGURATION—The unit shall be of compact designwith height not more than 443/4" [1137 mm] off the roofcurb andwidth-length not more than 84" [2134 mm] x 118" [2997 mm].

ACCESSORY EQUIPMENT—The following accessories shall befactory supplied as specified: Roofcurb, economizer with factoryinstalled plug in wiring harness, relief damper, and thermostat withtwo-stage heating/two-stage cooling (automatic changeover).

Before proceeding with installation, referto installation instructions packagedwith each model, as well as complyingwith all Federal, State, Provincial, andLocal codes, regulations, and practices.

RHEEMAIR CONDITIONINGDIVISION

P.O. Box 17010, Fort Smith, Arkansas 72917-7010

“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”

PRINTED IN U.S.A. 12-97 DC FORM NO. R11-818 REV. 5Supersedes Form No. R11-818 Rev. 4