commercial ventilation - pavo promet vent · pdf file64 65 commercial ventilation when the air...

10
65 64 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice ® is a leader in public sector ventilation with the New Vario Range of wall, window and flush-mounting units supported by the CA-V0 and CA in-line centrifugal fans offering a very wide choice to suit most applications. The range is completed by the “Tiracamino” chimney fan which is used to improve the updraught in open-flued chimneys. 02.COMMERCIALE DEF 30-06-2003 17:20 Pagina 64

Upload: vuongthien

Post on 06-Feb-2018

223 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: COMMERCIAL VENTILATION - Pavo Promet Vent · PDF file64 65 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice® is a leader in public sector

6564

COMMERCIAL VENTILATION

When the air is“good” the quality ofour work improves.Vortice® is a leader in publicsector ventilation with theNew Vario Range of wall,window and flush-mountingunits supported by the CA-V0 and CA in-linecentrifugal fans offering a verywide choice to suit mostapplications.The range is completed bythe “Tiracamino” chimney fanwhich is used to improve theupdraught in open-fluedchimneys.

02.COMMERCIALE DEF 30-06-2003 17:20 Pagina 64

Page 2: COMMERCIAL VENTILATION - Pavo Promet Vent · PDF file64 65 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice® is a leader in public sector

66 67

A

B

E

C D A B D

C

A B C D E

150/6” 215 218 31 97.5 2 185÷190

230/9” 294 297 31 130 2 257÷262

300/12” 390 393 31 147 2 324÷329

A B C D

150/6” 300 9.5 10.5 135 260÷265

230/9” 400 10 11 180 335÷340

300/12” 495 10.5 11.5 210 435÷440

AXIAL SUPPLY AND EXHAUST FANS WITH MANUAL OR AUTOMATIC SHUTTERS

VORTICE® VARIO RANGE

Dimensions (mm)

■ The new line of Vortice Varioexhaust/supply fans provide amodern and flexible solution toimprove the quality of air webreathe daily in any domesticor commercial environment:dwellings, shops & cafes,sports centers/gyms,restaurants, public houses,offices, schools, communityhalls and many more…

■ The new Vortice Vario models areamong the best of their categoryin terms of performance and lowenergy consumption thanks tohighly efficient impellers.

■ Published performances and dataare third party certified asindicated in IMQ data label.

■ Great care has been taken toensure extremely low noise levels.All technical data has beencertified by TÜV.

■ The outer casing is made fromshock-resistant UV stabilised ABS.Structural components in UVresistant ABS, internal componentsfrom shock resistant PS.

➀ Model for installation on glass/panel/wall➁ Built-in installation.

■ Vortice Vario fans are carefullydesigned to provide a lowenvironmental impact, usingrecyclable materials and following thenew “Design for Disassembly”technique to provide easy andenvironmentally friendly disposal ofcomponents. Vortice avoided pollutingtechnologies in the production cycle,and even the packaging of theproducts adopts recycled paper andsafe non-polluting inks. Energyconsumption is optimised both duringproduction and operation. Noisepollution has also been minimised.

■ All fans are IPX4 rated incompliance to IEC EN 60529standards both inside and outside.

■ Vortice Vario fans are EC marked inaccordance with the Low VoltageDirective EEC 73/23 and theElectromagnetic CompatibilityDirective 89/336. All fans are alsoIMQ (Italian Safety Institute) certifiedin compliance with EN 60335-2-80and EN 60529 standards.

Wiring diagrams shown on page XXVII.

EASYAND QUICKTO INSTALLThe whole range is manufactured to match high technologyspecifications and provide ease of installation. Based on this practicalapproach all installation procedures are significantly simplified toreduce time and save money during set-up and installation.

HIGH FLEXIBILITYVortice Vario fans are designed to provide high flexibilityand a wide choice of applications in order to satisfy eventhe most demanding requirements.

m3 /

h

l/s

AV ~ 50/60

Hz WLp dB(A)

3 m kg IP °Cmax

Delivery

RpmProduct Approvals InsulationCode

150/6” P

12611 220-240 18 0.10 1340 235 65.3 37.5 2.07 cl. II X4 50

150/6” AR12612 220-240 25 0.11 1340(1) 235(1) 65.3(1)

37.5 2.07 cl. II X4 502040(2) 150(2) 41.7(2)

230/9” AR12452 220-240 26 0.13 790(1) 480(1) 133(1)

35.6 3.45 cl. II X4 501080(2) 310(2) 86(2)

300/12” AR12412 220-240 45 0.21 840(1) 1050(1) 292(1)

40.2 6.13 cl. II X4 50(50 Hz)1085(2) 700(2) 194.4(2) 40(60 Hz)

12455 220-240 35/40 0.19 1200(1) 700(1) 194.4(1)

43.6 3.45 cl. II X4 50230/9” AR LL S

1300(2) 370(2) 102.8(2)

230/9” ARI LL S12456 220-240 35/40 0.19 1160(1) 680(1) 188.9(1)

45.3 3.88 cl. II X4 501260(2) 350(2) 97.2(2)

230/9” P

12451 220-240 22 0.10 790 480 133 35.6 3.45 cl. II X4 50

150/6” P LL S

12614 220-240 32 0.16 2110 380 105.6 46.9 2.07 cl. II X4 50

230/9” P LL S12454 220-240 32/38 0.18 1200 700 194.4 43.6 3.45 cl. II X4 50

150/6” AR LL S12615 220-240 35 0.17 2110(1) 380(1) 105.6(1)

49.6 2.07 cl. II X4 502520(2) 215(2) 59.7(2)

150/6” ARI12613 220-240 25 0.11 1330(1) 220(1) 61.1(1)

38.2 2.52 cl. II X4 501880(2) 130(2) 36.1(2)

300/12” AR LL S12415 220-240 75/90 0.41 1215(1) 1650(1) 458.3(1)

53.6 6.13 cl. II X4 50(50 Hz)1280(2) 920(2) 255.6(2) 40(60 Hz)

300/12” ARI12413 220-240 45 0.21 850(1) 1200(1) 333.3(1)

40.7 7.2 cl. II X4 50(50 Hz)1150(2) 850(2) 236.1(2)

40(60 Hz)

230/9” ARI12453 220-240 26 0.13 810(1) 450(1) 125(1)

35.7 3.88 cl. II X4 501080(2) 300(2) 83.3(2)

150/6” ARI LL S12616 220-240 35 0.17 2080(1) 350(1) 97.2(1)

49.1 2.52 cl. II X4 502460(2) 200(2) 55.6(2)

300/12” ARI LL S12416 220-240 75/90 0.41 1230(1) 1750(1) 486.1(1)

53.5 7.20 cl. II X4 50(50 Hz)1310(2) 1000(2) 277.7(2) 40(60 Hz)

(1)Extract - (2)Intake

NEW

Window/Wall hole dia ∅ Built-in installation hole mm

LONG LIFEwith ballbearings

AUTOMATICAutomaticshutters

REVERSIBLE BUILT-INPULL CORDManual

PRODUCT REFERENCES

LLSUPERBoostedperformance

SP A R I

02.COMMERCIALE DEF 30-06-2003 17:22 Pagina 66

Page 3: COMMERCIAL VENTILATION - Pavo Promet Vent · PDF file64 65 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice® is a leader in public sector

6968

WALL MOUNTING

PANEL / WALL MOUNTING WITH DARKROOM COWL

Model Code Kits required (codes)230/9” P 12451 panel : 13004 – wall: 13004 + 13018230/9” P LL S 12454 panel : 13004 – wall: 13004 + 13018230/9” AR 12452 panel : 13004 – wall: 13004 + 13018230/9” AR LL S 12455 panel : 13004 – wall: 13004 + 13018

ROOF MOUNTING ON WINDOW / PANEL

WINDOW / PANEL MOUNTING WITHEXTERNAL COWL AS A WIND BAFFLE

WALL MOUNTING FOR REMOTE APPLICATION

BUILT-IN WALL MOUNTING

BUILT-IN PANEL,CEILING AND FALSE CEILING MOUNTING

BUILT-IN WALL MOUNTEDFOR REMOTE APPLICATION

BUILT-IN ROOF MOUNTEDFOR REMOTE APPLICATION

SINGLE AND DOUBLE-GLAZED WINDOW

DOUBLE-GLAZED (OPENING) WINDOW

DOUBLE (OPENING) WINDOW SECONDARY-GLAZED

Model Code Kits required (codes)(1)

150/6” P 12611 none150/6” P LL S 12614 none 150/6” AR 12612 none150/6” AR LL S 12615 none230/9” P 12451 none230/9” P LL S 12454 none230/9” AR 12452 none230/9” AR LL S 12455 none300/12” AR 12412 none300/12” AR LL S 12415 none

AXIAL SUPPLY AND EXHAUST FANS WITH MANUAL OR AUTOMATIC SHUTTERS

Model Code Product

Kit MU 13018 Wall mounting kit with rods

Kit FF 150/6” 13024 Double opening window kit, Mod. 150/6” (including special flanges for protective grille holder and double window,gaskets for grille and flange, protective grille, duct and fixings)

Kit FF 230/9” 13025 Double opening window kit, Mod. 230/9” (including special flanges for protective grille holder and double window, gaskets for grille and flange, protective grille, duct and fixings)

Kit FF 300/12” 13026 Double opening window kit, Mod. 300/12” (including special flanges for protective grille holder and double window,gaskets for grille and flange, protective grille, duct and fixings)

Kit VV 150/6” 13021 Double opening window, secondary-glazed kit, Mod. 150/6” (including special flanges for protective grille holder and secondary glazing, gaskets for grille and window, protective grille, duct, nuts and screws)

Kit VV 230/9” 13022 Double opening window, secondary-glazed kit, Mod. 230/9” (including special flanges for protective grille holder and secondary glazing, gaskets for grille and window, protective grille, duct, nuts and screws)

Kit VV 300/12” 13023 Double opening window, secondary-glazed kit, Mod. 300/12” (including special flanges for protective grille holder and secondary glazing, gaskets for grille and window, protective grille, duct, nuts and screws)

Kit TE 150/6” 13001 Roof Cowl/Wind Baffle kit, Mod. 150/6” (including external roof cowl and base, gasket, threaded collar and intermediate rings)

Kit TE 230/9” 13002 Roof Cowl/Wind Baffle kit, Mod. 230/9” (including external roof cowl and base, gasket, threaded collar and intermediate rings)

Kit TE 300/12” 13003 Roof Cowl/Wind Baffle kit, Mod. 230/9” (including external roof cowl and base, gasket, threaded collar and intermediate rings)

Kit ML 150/6” 13015 Deep wall installation kit, Mod. 150/6” (including flush-mounting frame, feet, duct)

Kit ML 230/9” 13016 Deep wall installation kit, Mod. 230/9” (including flush-mounting frame, feet, duct)

Kit ML 300/12” 13017 Deep wall installation kit, Mod. 300/12” (including flush-mounting frame, feet, duct)

Kit SO 150/6” - 230/9” 13012 Ceiling, false ceiling and panel kit. Mod. 150/6” and 230/9” (including 2 ceiling brackets - M5 X 70 - M5 X 30 screws - springs - washers)

Kit SO 300/12” 13014 Ceiling, false ceiling and panel kit. Mod. 300/12” (including 4 ceiling brackets - M5 X 70 - M5 X 30 screws - springs - washers)

Kit TC 150/6” 13027 Spigot Plate for remote application, Mod. 150/6” (including flange for duct, coupling gasket, 4 nuts, 4 screws, M4 X 20/M4 X 50)

Kit TC 230/9” 13028 Spigot Plate for remote application, Mod. 230/9” (including flange for duct, coupling gasket, 4 nuts, 4 screws, M4 X 20/M4 X 50)

Kit TC 300/12” 13029 Spigot Plate for remote application, Mod. 300/12” (including flange for duct, coupling gasket, 4 nuts, 4 screws, M4 X 20/M4 X 50)

Kit SA 230/9” 13004 Darkroom cowl kit, Mod. 230/9” (darkroom and intermediate rings, external baffle and base, gasket, mesh) - UV stabilized material, painted with dark, non-reflective paint

Model Code Kits required (codes)(2)

150/6” P 12611 13021150/6” P LL S 12614 13021 150/6” AR 12612 13021150/6” AR LL S 12615 13021230/9” P 12451 13022230/9” P LL S 12454 13022230/9” AR 12452 13022230/9” AR LL S 12455 13022300/12” AR 12412 13023300/12” AR LL S 12415 13023

Model Code Kits required (codes)(3)

150/6” P 12611 13024150/6” P LL S 12614 13024 150/6” AR 12612 13024150/6” AR LL S 12615 13024230/9” P 12451 13025230/9” P LL S 12454 13025230/9” AR 12452 13025230/9” AR LL S 12455 13025300/12” AR 12412 13026300/12” AR LL S 12415 13026

Model Code Kits required (codes)(4)

150/6” P 12611 13018150/6” P LL S 12614 13018150/6” AR 12612 13018150/6” AR LL S 12615 13018230/9” P 12451 13018230/9” P LL S 12454 13018230/9” AR 12452 13018230/9” AR LL S 12455 13018300/12” AR 12412 13018300/12” AR LL S 12415 13018

Model Code Kits required (codes)150/6” P 12611 13001 + 13018150/6” P LL S 12614 13001 + 13018150/6” AR 12612 13001 + 13018150/6” AR LL S 12615 13001 + 13018230/9” P 12451 13002 + 13018230/9” P LL S 12454 13002 + 13018230/9” AR 12452 13002 + 13018230/9” AR LL S 12455 13002 + 13018300/12” AR 12412 13003 + 13018300/12” AR LL S 12415 13003 + 13018

WALL MOUNTING WITH EXTERNALCOWL AS A WIND BAFFLE

Model Code Kits required (codes)150/6” AR 12612 13001150/6” AR LL S 12615 13001230/9” AR 12452 13002230/9” AR LL S 12455 13002300/12” AR 12412 13003300/12” AR LL S 12415 13003

Model Code Kits required (codes)150/6” P 12611 13001150/6” P LL S 12614 13001 150/6” AR 12612 13001150/6” AR LL S 12615 13001230/9” P 12451 13002230/9” P LL S 12454 13002230/9” AR 12452 13002230/9” AR LL S 12455 13002300/12” AR 12412 13003300/12” AR LL S 12415 13003

Model Code Kits required (codes)150/6” AR 12612 13001 + 13018 + 2 items 13027150/6” AR LL S 12615 13001 + 13018 + 2 items 13027230/9” AR 12452 13002 + 13018 + 2 items 13028230/9” AR LL S 12455 13002 + 13018 + 2 items 13028300/12” AR 12412 13003 + 13018 + 2 items 13029300/12” AR LL S 12415 13003 + 13018 + 2 items 13029

Model Code Kits required (codes)150/6” ARI 12613 13012150/6” ARI LL S 12616 13012 230/9” ARI 12453 13012230/9” ARI LL S 12456 13012300/12” ARI 12413 13014 300/12” ARI LL S 12416 13014

Model Code Kits required (codes)150/6” ARI 12613 13027 + 13012 + 13015150/6” ARI LL S 12616 13027 + 13012 + 13015230/9” ARI 12453 13028 + 13012 + 13016230/9” ARI LL S 12456 13028 + 13012 + 13016300/12” ARI 12413 13029 + 13014 + 13017300/12” ARI LL S 12416 13029 + 13014 + 13017

Model Code Kits required (codes)150/6” ARI 12613 13001 + 13027 + 13012150/6” ARI LL S 12616 13001 + 13027 + 13012230/9” ARI 12453 13002 + 13028 + 13012230/9” ARI LL S 12456 13002 + 13028 + 13012300/12” ARI 12413 13003 + 13029 + 13014300/12” ARI LL S 12416 13003 + 13029 + 13014

Duct not included

Duct not included

Model Code Kits required (codes)(5)

150/6” ARI 12613 none150/6” ARI LL S 12616 none 230/9” ARI 12453 none230/9” ARI LL S 12456 none300/12” ARI 12413 none 300/12” ARI LL S 12416 none

BUILT-IN DEEP WALL MOUNTING

Model Code Kits required (codes)150/6” ARI 12613 13015150/6” ARI LL S 12616 13015 230/9” ARI 12453 13016230/9” ARI LL S 12456 13016300/12” ARI 12413 13017 300/12” ARI LL S 12416 13017

Duct not included

Duct not included

AVAILABLE KITS Optional kits for special installations are available on request

NEW

H

∅ DA

B C

20°20°

C

A

H

∅ D

B

∅ D

∅ D

∅ D A B C H

150/6” 13001 300 215 175 28 111

230/9” 13002 400 294 249 30 145

300/12” 13003 534 390 316 33 181

∅ D A B C H

150/6” 13027 171 215 175 8 30

230/9” 13028 240 294 249 10 30

300/12” 13029 300 390 316 12 30

∅ D

150/6” 13027 171

230/9” 13028 240

300/12” 13029 300

∅ D

150/6” 13015 171

230/9” 13016 240

300/12” 13017 300

∅ D ∅ D

150/6” 176 180 2

230/9” 245 250 2,5

300/12” 309 315 3

∅ D

150/6” 171

230/9” 240

300/12” 300

Roof cowl kit Spigot Plate

Duct diameter forSpigot Plate

Duct diameter for flush-mounting frame

Diameterof PVC ducts Light series for ventilation.Suitable for Vortice applications.With the following internal diameters.

Diameterof aluminium ductsFlexible. Suited for Vorticeapplications. With the followinginternal diameters.

Dimensions (mm)

ext.

ext.

Model code

Model int.Model int. ext. thickn.Model code ext.Model code ext.

ext.

Model code ext.

(1)No kit is required for window/panelswith thickness ranging from 3 to 38mm

Duct included

(2)For installation in double-glazed(opening) window with thicknessranging from 30 to 43mm

(3)For installation on double (opening)window with thickness rangingfrom230 to300mm.

(4)For installation on walls, with thicknessranging from 38 to 300mm

(5)No kit is required for walls with thick-ness ranging from 135 to 210mm

02.COMMERCIALE DEF 30-06-2003 17:52 Pagina 68

Page 4: COMMERCIAL VENTILATION - Pavo Promet Vent · PDF file64 65 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice® is a leader in public sector

7170

Pressure/performance curves

AXIAL SUPPLY AND EXHAUST FANS WITH MANUAL OR AUTOMATIC SHUTTERS

INSTALLATION OPTIONS AND REQUIRED KITS

Single-glazed window

Wall 1 13018 13018 13018 13018 13018 13018 13018 13018 13018 13018

Double-glazed (opening) window 1 13021 13021 13021 13021 13022 13022 13022 13022 13023 13023

Double (opening) window 1 13024 13024 13024 13024 13025 13025 13025 13025 13026 13026secondary-glazing

Window-mounted with darkroom cowl 1 13004 13004 13004 13004

Window / panel-mounted with 1 13001 13001 13001 13001 13002 13002 13002 13002 13003 13003external cowl

Roof application 1 13001 13001 13002 13002 13003 13003

Wall-mounted 2 13001 13001 13001 13001 13002 13002 13002 13002 13003 13003with external cowl 13018 13018 13018 13018 13018 13018 13018 13018 13018 13018

Wall-mounted for 13001 13001 13002 13002 13003 13003remote application 1 13018 13018 13018 13018 13018 13018(duct not included) 13027x213027x2 13028x2 13028x2 13029x213029x2

Built-in wall mounted

Built-in deep wall mounted 1 13015 13015 13016 13016 13017 13017

Panel

Ceiling 1 13012 13012 13012 13012 13014 13014

False ceiling

Roof-mounted for 13001 13001 13002 13002 13003 13003remote application 3 13027 13027 13028 13028 13029 13029(duct not included) 13012 13012 13012 13012 13014 13014

Built-in wall mounted 13027 13027 13028 13028 13029 13029for remote application 3 13012 13012 13012 13012 13014 13014(duct not included) 13015 13015 13016 13016 13017 13017

Thin wall 13001 13001 13002 13002 13003 13003mounted for 3 13018 13018 13018 13018 13018 13018remote application 13027 13027 13028 13028 13029 13029(duct not included) 13012 13012 13012 13012 13014 13014

Panel-mounted with darkroom cowl 1 13004 13004 13004 13004

Wall-mounted 2 13004 13004 13004 13004with darkroom cowl 13018 13018 13018 13018

150/

6” P

150/

6” P

LL

S

150/

6” A

R

150/

6” A

R L

LS

150/

6” A

RI

150/

6” A

RI L

LS

230/

9” P

230/

9” P

LL

S

230/

9” A

R

230/

9” A

R L

LS

230/

9” A

RI

230/

9” A

RI L

LS

300/

12”

AR

300/

12”

AR

LL

S

300/

12”

AR

I

300/

12”

AR

I LL

S

Num

ber o

f req

uire

d ki

ts

NEW

*DuctingCode Model

8501 175 mm flexible duct 3m length

8511 175 mm flexible duct 10m length

8502 243 mm flexible duct 3m length

8512 243 mm flexible duct 10m length

8503 305 mm flexible duct 3m length

8513 305 mm flexible duct 10m length

*Flat roof upstandCode Model

8558 Flat Roof Upstand 150/6”

8559 Flat Roof Upstand 230/9”

8560 Flat Roof Upstand 300/12”

*Soaker sheet with integral upstandCode Model

8550 Soaker Sheet with integral upstand 150/6”

8551 Soaker Sheet with integral upstand 230/9”

8552 Soaker Sheet with integral upstand 300/12”

*Spigot platesCode Model

8140 260 × 260 Spigot Plate ∅ 171 mm

8141 350 × 350 Spigot Plate ∅ 240 mm

8141 440 × 440 Spigot Plate ∅ 300 mm

* Available only in UK

m3/h

0

mmH2OPa

p t

5025 75

3

2

1

00

qv

80 160 240

l/s

20

10

0m3/h

0

mmH2OPa

p t

5025 75

3

2

1

00

qv

80 160 240

l/s

20

10

0m3/h

0

mmH2OPa

p t

60 120

3

2

1

00

qv

200 400 600

l/s

20

10

0

m3/h

0

mmH2OPa

p t

60 120

3

2

1

00

qv

200 400 600

l/s

20

10

0

m3/h

0

mmH2OPa

p t

200100 300

4

3

2

1

00

qv

600 900 1200

l/s

30

20

10

0300 m3/h

0

mmH2OPa

p t

10050 200

5

4

3

2

1

00

qv

300 450 600 750

l/s

40

30

20

10

0150

150/6” P

230/9” AR 300/12” AR 230/9” AR LL S

150/6” AR 230/9” P

m3/h

0

mmH2OPa

p t

60 120

3

2

1

00

qv

200 400 600

l/s

20

10

0m3/h

0

mmH2OPa

p t

200100 300

4

3

2

1

00

qv

600 900 1200

l/s

30

20

10

0300

150/6” AR LL S 300/12” AR LL S

02.COMMERCIALE DEF 30-06-2003 17:52 Pagina 70

Page 5: COMMERCIAL VENTILATION - Pavo Promet Vent · PDF file64 65 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice® is a leader in public sector

7372

AXIAL SUPPLY AND EXHAUST FANS WITH MANUAL OR AUTOMATIC SHUTTERS

110

60

3522

170 175

CONTROLLERS“Wall mounted reversible speed controllers suitable for use with the automatic Vortice Vario models.

CR5(code 12943) ■ 5 speed controller■ On/Off ■ Reversible■ Can be used to regulate more

then one fan.■ Maximum load 100 W.

CREN(code 12944)■ Variable electronic speed controller■ On/Off■ Reversible■ Natural Ventilation■ Can be used to regulate more then

one fan■ Maximum load 1,2 A

CRN(code 12945) ■ On/Off■ Reversible■ Natural Ventilation■ Can be used to regulate more

then one fan■ Maximum load 100 W

CR5N (code 12941)■ 5 speed controller■ On/Off■ Reversible■ Natural Ventilation■ Can be used to regulate more thenone fan■ Maximum load 100 W

43120

SCR5(code 12930)■ 5 speed controller■ On/Off■ Reversible■ Can be flush mounted using kit SCB5■ Can be used to regulate more then one fan■ Maximum load 100 W

Kit SCB5(code 22483)■ Converts the SCR5 controller

to a flush mounted version

120

36 49

Televortice(code 22391)■ Infrared remote control■ 3 speeds■ On/Off■ Reversible

ENVIRONMENTAL SENSORSEnvironmental sensors are designed to detect specific environmentalconditions (humidity, temperature, presence of a moving body andair quality) and suitable for use with all Vortice Vario models.These sensors can also be connected to the CR range of Variospeed controllers.

C HCS-HUMIDITY(code 12994)Measures ambient relative humidity (R.H.), and starts the Vortice Vario fan when the R.H. exceeds 65%.The sensor can also be wired to allow the unit to be switched on when the R.H. is below 65%, and incorporates an over-run timer (adjustable between 3 and 20 minutes).

C PIR-MOVEMENT DETECTOR(code 12998)Detects the presence of a moving body within its sensor range, and starts the fan automati-cally. The built-in over-run timer can be adjusted between 3 and 20 minutes.

C TIMER(code 12999)Adjustable over-run timer (adjustable between 3 and 20 minutes).

C TEMP-TEMPERATURE(code 12992)Measures ambient room temperature, and starts the Vortice Vario fan when the temperature exceeds the preset value. Once the temperature drops below the presetvalue, the unit will over-run for between 3 and 20 minutes (dependent on setting).

C SMOKE(code 12993)Measures the air quality, detecting the presence of cigarette smoke, odours and other pollutants, and starts the Vortice Vario fan when the concentration of pollutants exceeds the preset value. The unit will also over-run for between 3 and 20 minutes (dependent on setting).

144

54

55,8

■ Supply power: 220-240 V■ Frequency: 50/60Hz■ Maximum load: 3 A■ Operating temperature: 50 °C■ Protection class: IP20

■ Supply power: 220-240 V■ Frequency: 50/60Hz■ Operating temperature: 50 °C■ Protection class: IP20■ The controller can also be recessed using a suitable backbox.

■ It can control more then one exhaust fan at the time for amaximum load of 1,2 A

■ It can control more then one exhaust fan at the time for amaximum load of 100 W

■ It can control more then one exhaust fan at the time for amaximum load of 100 W

02.COMMERCIALE DEF 30-06-2003 17:55 Pagina 72

Page 6: COMMERCIAL VENTILATION - Pavo Promet Vent · PDF file64 65 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice® is a leader in public sector

CA 100-V0 D

16008220-

5085 0.38 2540 235 65.3 40 392 56

2.4 cl.II X4 50240 65* 0.32* 1660* 150* 41.7* 30* 274* 51*

CA 125-V0 D16018

220-50

85 0.40 2470 360 100 36 353 562.3 cl.II X4 50240 67* 0.34* 1480* 210* 58.3* 25* 245* 45*

CA 150-V0 D

16028 220- 50 85 0.41 2390 500 138.9 34 333 56 2.6 cl.II X4 50240 70* 0.34* 1400* 280* 77.8* 20* 196* 44*

CA 200-V0

16045220- 50/

180 0.83 2660 870 241.7 58 568 64 4 cl.II X4 55240 60

CA 200-V0 Q

16035220- 50/

100 0.35 2290 700 194.4 37 363 59 4.3 cl.II X4 50240 60

CA 250 - V0

16055220- 50/

200 0.9 2460 1130 313.9 58 568 64 4.3 cl.II X4 55240 60

CA 315 - V0

16065220- 50/

200 0.9 2560 1250 347.2 56 549 67 5.1 cl.II X4 55240 60

AW

Lp

dB

(A)

3 m

kg °Cmax

m3 /

h

mm

H2O

Pa

l/s

HzV

P max

7574

➀ ➁

LONG LIFE 30.000 h

* max/min

IN-LINE, CENTRIFUGAL EXTRACTOR FANS IN SELF-EXTINGUISHING V0 PLASTIC WITH IPX4 PROTECTION FOR DUCTED INSTALLATION

CA V0 RANGE WITH LL MOTOR

AwardsHonourable mention,1994 Golden Compass, Italy

Wiring diagrams shown on page XXVII.

➀ Installation with duct intake and outlet.➁ Installation with free intake and duct outlet.➂ New: mounting brackets included

■ For ventilation of pubs,restaurants, shops,workshops, offices, sportshalls and canteens.

■ Seven models.■ 2 speed motors (100/125/150).■ IMQ information label certifies third

party product data and performance.■ Complies with the CEI 61-28

standards.■ Splash proof protection.■ Complete with fixing bracket.Design: F. Trabucco and M. Vecchi

Conforms with ISO 3744 for noise and pressure levels

Product Code Rpm

Delivery

Approvals

Insu

lati

on

Pro

tect

ion

Supply and install a CA-V0 in-line centrifugal extract fan for installationwithin duct applications or in ceilings as manufactured exclusively byVortice only for Vortice. All performance data should be third party IMQ(BEAB recognised equivalent) verified. The frame and body should bemanufactured from V0 plastic to provide maximum self-extinguishingproperties. The intake port should have an integral protection grille and aspecial grease collector. The motor should be a stainless steel ball bearing, shielded pole motor(30,000-hour guarantee), include a thermal cut out device, be capable ofoperating at an ambient temperature up to 50°C and be speedcontrollable (using an optional controller). The fan turbine should bebalanced directly onto the motor. Model should be available in 100mm,125mm, 150mm (dual speed), 200mm, 250mm and 315mm sizes(single speed), designed to fit standard duct diameters.

➏➐

CA V0 A B ∅ C ∅ D E F

100 D 30 250 250 97 30 281

125 D 30 250 250 122 30 281

150 D 30 305 300 147/157 30 306

200 30 280 340 197 30 385

200 Q 30 280 340 197 30 385

250 30 305 340 247 55 385

315 40 340 400 312 75 415

A

C B

E

D

F

Galvanised sheet-metal brackets(100-125-150)

A B C D E F

Bracket 186 40 40 20 156 10

➊ Ball-bearing-mounted motor (30,000 h of guaranteed continuous operation).➋ Turbine fan balanced directly on motor.➌ Thermal overload protector.➍ VO resin plastic frame with maximum self-extinguishing properties.➎ Standard diameters. 150mm dia. model can also be adapted to 160 mm dia. tubes.➏ Special “grease-collector”.➐ Safety grille on intake port.

Dimensions (mm)∅ C

∅ D

∅ D

B

EA

A

02.COMMERCIALE DEF 30-06-2003 17:58 Pagina 74

Page 7: COMMERCIAL VENTILATION - Pavo Promet Vent · PDF file64 65 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice® is a leader in public sector

7776

IN-LINE, CENTRIFUGAL EXTRACTOR FANS IN SELF-EXTINGUISHING V0 PLASTIC WITH IPX4 PROTECTION FOR DUCTED INSTALLATION

Backdraught Shutter(code 22550-22555-22560-22565-22570-22575)Galvanized sheet-metal non-return shutter with aluminium finsand return springs to prevent back-draughts or penetration ofrain when the unit is turned off.

SCB Kit (code 22483)Kit to connect SCNR to built-in (description and data onpage 54).

SCNR (code 12912)Electronic speed controller (description and data on page 54).

SCNRB (code 12971)Flush-fitting electronic speed controller (description and dataon page 54).

Protective Grid (code 51150-51350)Fine protection mesh for fitting at end of duct.

Fixed grille (code 22010-22020)For outside wall.

MODEL CODE

SCNR (electronic speed controller) 12912 for all products

SCNRB (flush-fitting electronic speed controller) 12971 for all products

SCB Kit (to convert SCNR to flush) 22483 for SCNR

CA-S 100 (backdraught shutter) 22550 16008

CA-S 125 (backdraught shutter) 22555 16018

CA-S 150 (backdraught shutter) 22560 16028

CA-S 200 (backdraught shutter) 22565 16035 - 16045

CA-S 250 (backdraught shutter) 22570 16055

CA-S 315 (backdraught shutter) 22575 16065

GFI 10 (fixed grille) 22010 16008

GFI 12/15 (fixed grille) 22020 16018 - 16028

TRA 250 (protective grid) 51150 16035 - 16045 - 16055

TRA 350 (protective grid) 51350 16065

PGR 250 (gravity shutter) 50150 16055

PGR 300 (gravity shutter) 50250 16065

PGR 350 (gravity shutter) 50350 16065

PRODUCTS

SCNR5 CA-V0 (code 12986)Electronic, speed controller.

mmH2OPa

60

45

30

15

0

p t

400

200

0m3/h

qv

l/s 0 100 200 300

0 400 1200800 1600

400

m3/h

0

mmH2OPa

p t50 100

40

30

20

10

00 100

qv

300 400

l/s

300

100

0200 m3/h

0

mmH2OPa

p t

50 150

40

30

20

10

00 150

qv

450 600

l/s

300

150

0300

100

0 300 900600m3/h

qv

l/s 0 100 200

60

45

30

15

0

mmH2OPa

p t

400

200

01200

300

m3/h

mmH2OPa

p t

50

40

30

20

10

0 10050

qv

200 250

l/s

400

200

0150

35 700

CA 250 V0

CA 315 V0

Pressure/performance curves

02.COMMERCIALE DEF 30-06-2003 17:59 Pagina 76

Page 8: COMMERCIAL VENTILATION - Pavo Promet Vent · PDF file64 65 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice® is a leader in public sector

78 79

➀ ➁

LONG LIFE 30.000 hCA RANGE

■ Suitable for commercial andindustrial applications:kitchens, bathrooms,offices, laboratories,factories, stores, drycleaners, shops,restaurants, bars, theatres,dance halls, etc.

■ Ball-bearing-mounted motor withexternal rotor motor and hand-operated resettable thermal cutout.

■ IMQ information label certifiesthird party product data andperformance.

■ Complies with the CEI 61-28standards.

■ Turbine fan balanced directly onthe motor.

■ Motor-holder made of steel andpaint-finished with furnace-hammered epoxy powder forperfect weather protection.

■ Galvanized steel motor mountingbrackets and air flow deflectors.

■ Speed can be adjusted using anoptional controller.

■ Complete with fixing bracket.

Wiring diagrams shown on pageXXVII.

➀ The CA units can be mounted in any position. Standard diametersfit commercially available ducting.

➂ New: mounting brackets included.

IN-LINE CENTRIFUGAL EXTRACTOR FANS SUITABLE FOR DUCTED INSTALLATION

* Values taken at the intake side with funnelled delivery and free intake Conforms with ISO 3744 for noise and pressure levels

AV W

Lp

dB

(A)*

3 m

kg max°C

m3 /

h

mm

H2O

Pa

l/s

P max

Hz

CA 100 16000 220- 50/ 85 0.4 2530 250 69.4 36 353 57 3 cl.I X4 55240 60

CA 100 Q 16001 220- 50 40 0.19 1870 170 47.2 30 294 48 3 cl.I X4 55240

CA 125 16010 220- 50/ 85 0.4 2390 360 100.0 32 314 57 2.8 cl.I X4 55240 60

CA 125 Q 16011 220- 50 40 0.19 1480 210 58.3 29 284 43 2.8 cl.I X4 55240

CA 150 16020 220- 50/ 85 0.4 2490 450 125.0 27 265 58 3.4 cl.I X4 55240 60

CA 160 16070 220- 50/ 180 0.85 2670 780 216.7 60 588 65 5.6 cl.I X4 50240 60

CA 160 Q 16071 220- 50 75 0.32 2440 550 152.8 35 343 61 4.5 cl.I X4 55240

CA 200 16040 220- 50/ 180 0.75 2710 950 263.9 55 539 64 5.3 cl.I X4 50240 60

CA 200 Q 16030 220- 50 75 0.33 2420 720 200.0 36 353 65 4.6 cl.I X4 55240

CA 250 16050 220- 50/ 200 0.9 2540 1200 333.3 58 568 62 5.4 cl.I X4 50240 60

CA 250 Q 16051 220- 50 120 0.51 1710 800 222.2 45 441 51 5.4 cl.I X4 55240

CA 315 16061 220- 50/ 260 1.3 2550 1750 486.1 75 735 67 6.9 cl.I X4 50240 60

CA 315 Q 16060 220- 50 130 0.59 2640 1300 361.1 54 529 64 6.7 cl.I X4 55240

Product Code Rpm Insulation

Pro

tect

ionDelivery

Approvals

IN-LINE CENTRIFUGAL EXTRACTOR FANS SUITABLE FOR DUCTED INSTALLATION

Dimensions (mm)

Accessories (description and data on pages 125-129).

Model Code Products

SCNR (electronic speed controller) 12912 for all products (except code 16061)

SCNR/M (electronic speed controller) 12982 for all productsSCNRB (flush-fitting electronic speed controller) 12971 for all products

SCB Kit (to convert SCNR to flush) 22481 for SCNRSCB5 Kit (to convert SCNR/M to flush) 22483 for SCNR/M

CA-S 100 (backdraught shutter) 22550 16000 - 16001CA-S 125 (backdraught shutter) 22555 16010 - 16011CA-S 150 (backdraught shutter) 22560 16020CA-S 160 (backdraught shutter) 22561 16070 - 16071CA-S 200 (backdraught shutter) 22565 16030 - 16040CA-S 250 (backdraught shutter) 22570 16050 - 16051CA-S 315 (backdraught shutter) 22575 16060 - 16061CA-G 100 (protection grille) 22750 16000 - 16001CA-G 125 (protection grille) 22755 16010 - 16011CA-G 150 (protection grille) 22760 16020CA-G 160 (protection grille) 22762 16070 - 16071CA-G 200 (protection grille) 22765 16030 - 16040CA-G 250 (protection grille) 22770 16050 - 16051CA-G 315 (protection grille) 22775 16060 - 16061

GFI 10 (fixed grille) 22010 16000 - 16001

GFI 12/15 (fixed grille) 22020 16010 - 16011 - 16020

TRA 250 (protective grid) 51150 16030 - 16040 - 16050 - 16051

TRA 350 (protective grid) 51350 16060 - 16061

PGR 250 (gravity shutter) 50150 16050 - 16051

PGR 300 (gravity shutter) 50250 16060 - 16061PGR 350 (gravity shutter) 50350 16060 - 16061

A

A

C

B

E

D

F

∅ D∅ E

FB

A

C

A B C D E F

Bracket 245 100 40 80 215 10

Galvanised sheet-metal brackets(160-200-250-315)

CA A B C ∅ D ∅ E F G

CA 100 20 235 300 250 97 25 282

CA 125 20 235 300 250 122 25 282

CA 150 25 265 350 300 147 25 307

CA 160 30 287 390 340 157 25 386

CA 200 25 270 390 340 197 25 386

CA 250 25 280 390 340 247 44 385

CA 315 Q 40 325 450 400 312 71 416

CA 315 40 307 450 400 312 44 416

02.COMMERCIALE DEF 30-06-2003 18:00 Pagina 78

Page 9: COMMERCIAL VENTILATION - Pavo Promet Vent · PDF file64 65 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice® is a leader in public sector

ASPIRATORI DA MURO CON SCARICO DIRETTO ALL’ ESTERNO

8180

IN-LINE CENTRIFUGAL EXTRACTOR FANS SUITABLE FOR DUCTED INSTALLATION

30

24

18

12

6

0500400300200100

200

100

0

Pressure/performance curves

60

48

36

24

12

015001200900600300

470

230

0

Pressure/performance curves

02.COMMERCIALE DEF 30-06-2003 18:00 Pagina 80

Page 10: COMMERCIAL VENTILATION - Pavo Promet Vent · PDF file64 65 COMMERCIAL VENTILATION When the air is “good” the quality of our work improves. Vortice® is a leader in public sector

∅ A B C ∅ D E F G A1 B1 C1 D1

Tiracamino 405 410 357 10 38 518 480 401 357 140 37

∅ D

C

B

G FE

∅ A

mmH2O

p t

Pa

150

100

50

0m3/h

qv

l/s 0 100

20

15

10

5

00 200 600400

200

800

BA

A B

SCNR 120 43

15000 220-240 120 0.5 1400 750 208.3 19 186 52 170 14.3 cl. I

A

V ~

50

Hz

W

Lp

dB

(A)

3 m

kg

Tiracamino

m3 /

h

mm

H2O

Pa

l/s

P max

83

D1C1

B1

A1

82

RADIAL EXTRACT UNIT FOR CHIMNEY TOPS

TIRACAMINO® CHIMNEY EXTRACT FAN

Dimensions (mm)

Pressure/performance curve

➀ Typical installation (if the internal size of the chimney flue is less than15 × 15 cm or 17 cm diameter, the efficiency of the fan may be reduced)

■ Designed to draw out smokefrom fireplace. Can be usedas a normal extractor fanwhen the fireplace is not lit.Not suitable for usewith gas fires.

■ Ball-bearing-mounted inductionmotor to withstand hightemperatures (approximately200°C) for long periods ofoperation.

■ Information label shows IMQ thirdparty data and performancecertification.

■ Weather proof steel constructionand anti-corrosion, polyester resinprotection.

■ Supplied with steel safety cablefor long-term anchoring of fan tothe base.

■ Protection grille with steel safety,anti-bird rings.

■ Complies with the CEI 61-28standards.

■ Advanced blade design reducessoot build up.

■ Complete with variable speedcontroller SCNR and base frame.

Accessories■ Protective grille (Code 22700) for

covering the moving parts whenthe unit is installed at low level(description on page 126).

■ SCB Kit to flush-mount the SCNRcontrol unit (description on page 54).

Wiring diagrams shown on page XXVII.

Conforms with ISO 3744 for noise and pressure levels

Product Code Rpm

Delivery

ApprovalsInlet

∅ mm Insulation

Pro

tect

ion

Supply and install a Tiracamino centrifugal extract fan for installation on chimney tops as manufactured exclusively by Vortice only forVortice. All performance data should be third party IMQ (BEABrecognised equivalent) verified. The fan should be class 1 insulatedand of of weather proof steel construction with anti-corrosion, polyesterresin protection, It should have an extract performance of 208.3 l/s infree air and have an inlet diameter of 170mm. The motor should be a ball bearing mounted induction motor designedto withstand high temperatures (approx. 200°C for long periods ofoperation. The motor should include a thermal cut out device and bespeed controllable by using the speed controller supplied. The turbineshould have an advanced blade design to reduce soot build up andbe protected by a circular anti-bird grille. It should be suppliedcomplete with fitting basee and steel safety cable for stable anchoring.

02.COMMERCIALE DEF 30-06-2003 18:00 Pagina 82