common circular connector - smcpneumatics.com · 48 ® series sv circular connector dimensions:...
TRANSCRIPT
43®
Circular Connector
Applicable series
Cassette base manifoldSV1000/SV2000
Tie-rod base manifoldSV1000/SV2000/SV3000/SV4000
• Number of connectors: 26 pins
IP67 protection
Tie-rod base
Cassette base
Manifold
Specification SheetsV
alve Manifold
Specifications
Flat Ribbon C
ableS
ing
le Valve
Su
b-p
lateD
-sub
Co
nn
ector
EX
250E
X120
Circu
larC
on
necto
rE
X500
Valve M
anifo
ldC
om
mo
nS
pecificatio
ns
44 ®
How to Order
44
• Tie-rod base
• Cassette base
Series
SS5V –W1
Enclosure IP67specification
12
SV1000SV2000
SS5V – – – –W 0516CD1DIN rail length
Standard length
Specify a rail longer than the standard length.
Nil3
20
Note
Double wiring specification
Specified layout(Up to 18 solenoids possible.)
Symbol02
0902
18
Stations2 stations
9 stations2 stations
18 stations
Series1234
SV1000SV2000SV3000SV4000
P, E port positionUDB
U side (2 to 10 stations)D side (2 to 10 stations)Both sides (2 to 20 stations)
......
......
For 3 stations
For 20 stations
... ...
MountingDirect mountDIN rail mount (with DIN rail)DIN rail mount (without DIN rail)
NilDD0D3
D20
For 3 stations
For 20 stations
... ...
A, B port size (inch)A, B portSymbol
N1N3N7N3N7N9N7N9N11N9N1102N03N02T03TM
ø1/8" One-touch fittingø5/32" One-touch fittingø1/4" One-touch fittingø5/32" One-touch fittingø1/4" One-touch fittingø5/16" One-touch fittingø1/4" One-touch fittingø5/16" One-touch fittingø3/8" One-touch fittingø5/16" One-touch fittingø3/8" One-touch fittingNPT 1/4NPT 3/8NPTF 1/4NPTF 3/8A, B ports mixed
Supply/Exhaust block assembly specificationInternal pilot specificationInternal pilot/Built-in silencerExternal pilot specificationExternal pilot/Built-in silencer
NilSR
RS
Note 1)
Note 2)
Note
Double wiring specification
Specified layout(Up to 24 solenoids possible.)
Symbol02
1202
20
Stations2 stations
12 stations2 stations
20 stations
......
......
Note 1)
Note 2)
Valve stationsNote
Double wiring specification
Specified layout(Up to 24 solenoids
possible.)
Symbol02
1202
20
Stations2 stations
12 stations2 stations
20 stations
......
......
Note 1)
Note 2)
– – –05 U10CD
U
ø5/16"One-touch fitting
P, E port Applicable series
SV1000
SV2000
SV3000
SV4000
ø3/8"One-touch fitting
ø3/8"One-touch fitting
ø3/8"One-touch fitting
NPT 3/8
NPTF 3/8
A, B port size (metric)A, B portSymbol
C3C4C6C4C6C8C6C8C10C8C10C120203
02F03FM
ø3.2 One-touch fittingø4 One-touch fittingø6 One-touch fittingø4 One-touch fittingø6 One-touch fittingø8 One-touch fittingø6 One-touch fittingø8 One-touch fittingø10 One-touch fittingø8 One-touch fittingø10 One-touch fittingø12 One-touch fittingRc 1/4Rc 3/8G 1/4G 3/8A, B ports mixed
ø8One-touch fitting
P, E port Applicable series
SV1000
SV2000
SV3000
SV4000
ø10One-touch fitting
ø12One-touch fitting
ø12One-touch fitting
Rc 3/8
G 3/8
Note) In case of D0, only DIN rail fittings are attached.
Note)
Note 1) Double wiring specification: Single, double and 3 position solenoid valves can be used on all manifold stations.Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout.
Note 2) Specified layout: Indicate wiring specifications on a manifold specification sheet. (Note that double and 3 position valves cannot be used where single solenoid wiring has been specified.)
Note 1) Double wiring specification: Single, double and 3 position solenoid valves can be used on all manifold stations.Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout.
Note 2) Specified layout: Indicate wiring specifications on a manifold specification sheet. (Note that double and 3 position valves cannot be used where single solenoid wiring has been specified.)
∗ In case of mixed specification (M), indicate separately on a manifold specification sheet.
When a DIN rail longer than the specified stations is required. (Specify a rail longer than the standard length.)
∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids.
∗
∗
Valve stationsSeries SV1000
Series SV2000
Circular Connector
Series SV
45®
How to Order Manifold Assemblies (Order Example)
Example (SV1000)
ManifoldSS5V1-W16CD-06B-C6 (1 set)
SS5V1-W16CD-06B-C6 ............ 1 set (manifold part no.)
∗ SV1100-5FU ......... 4 sets (single solenoid part no.)
∗ SV1200-5FU ......... 2 sets (double solenoid part no.)
How to Order Solenoid Valves
Double solenoid
SV1200-5FU (2 sets)
Single solenoid
SV1100-5FU (4 sets)
32
1
Stations
U side
D side
DD
DD
DD
Circular Connector Series SV
Manual override
Rated voltage
Nil: Non-locking push type D: Slotted locking type
SV – –1 1 0 0 F5
56
24VDC12VDC
Note) Available with manifold block for station additions. Refer to pages 77 and 81.
Light/Surge voltage suppressorWith light and surge voltage suppressor
With surge voltage suppressorUR
Pilot specification
∗ External pilot specification is not available for 4 position dual 3 port valves.
∗ 4 position dual 3 port valves are applicable to series SV1000 and SV2000 only.
∗ Built-in back pressure check valve type is applicable to series SV1000 only.
∗ Back pressure check valve is not available for 3 position closed center and 3 position pressure center.
∗ Effective area of the built-in back pressure check valve type is reduced approximately 20%.
Internal pilotExternal pilot
NilR
Back pressure check valveNoneBuilt-in
NilK
Series1234
SV1000SV2000SV3000SV4000
Type of actuation12345ABC
2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center4 position dual 3 port valve: N.C./N.C.4 position dual 3 port valve: N.O./N.O.4 position dual 3 port valve: N.C./N.O.
Manifold
Specification SheetsV
alve Manifold
Specifications
Flat Ribbon C
ableS
ing
le Valve
Su
b-p
lateD
-sub
Co
nn
ector
EX
250E
X120
Circu
larC
on
necto
rE
X500
Valve M
anifo
ldC
om
mo
nS
pecificatio
ns
46 ®
Series SV Circular Connector
10C/16C Circular Connector Type (26 pins)
Model Maximum number of solenoids
Tie-rod base type 10SV1000
to SV4000
24
1824
SV1000SV2000
Cassette base type 16
Manifold Electrical Wiring
Light/Surgevoltage suppressor
Common
Common
SOL. B
SOL. A
SOL. B
SOL. A
SOL. B
SOL. A
SOL. BStation 1
Station 2
Station 11
Station 12
SOL. A
Light/Surgevoltage suppressor
Light/Surgevoltage suppressor
Light/Surgevoltage suppressor
Usable number of solenoids
• This circuit has double wiring specifications for up to 12 stations. Since the usable number of solenoids differs depending on the manifold type, refer to the table below. In the case of single solenoids, connect to SOL. A. Furthermore, when wiring is specified on a manifold specification sheet, connections are made without skipping any connectors, and signals A for single and A, B for double are in order 1→2→3→4, etc.
• Stations are counted starting from station 1 on the D side (connector side).
• Since solenoid valves do not have polarity, either the +COM or –COM can be used.
47®
Dimensions: Series SV1000 for Circular Connector
Circular Connector Series SV
( )
UDB
C3, N1C4, N3C6, N7
47
• Cassette base manifold: SS5V1-W16CD - Stations (S, R, RS) -• When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged. • External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.
L1L2L3L4
L n 2148 137.5119.3 14.5
5185.5175 150.8 17.5
6185.5175 161.312
7198 187.5171.813
8210.5200 182.314
9223 212.5192.815
10235.5225 203.316
11248 237.5213.817
12248 237.5224.312
13260.5250 234.813
14273 262.5245.314
15285.5275 255.815
16298 287.5266.316
17310.5300 276.817
18310.5300 287.3 11.5
4173 162.5140.3 16.5
3160.5150 129.8 15.5
L dimensions n: Stations
A
B
A
B
A
B
A
B
A
B
(Pitch)A
B
AB
Notch(to align connector position)
DIN rail holding screw
(Station n) (Station 1)
(Rail mounting hole pitch: 12.5)
One-touch fitting[1(P), 3/5(E) port]Applicable tubing O.D.: ø8
N9
P1
5 3 E
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
U side D side
P1
5 3 E
P1
5 3 E
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
One-touch fitting[X: External pilot port]Applicable tubing O.D.: ø4
N3
One-touch fitting[PE: Pilot EXH port]Applicable tubing O.D.: ø4
N3
With external pilot specification
One-touch fitting[4(A), 2(B) port]Applicable tubing O.D.: ø3.2, N1
ø4, N3ø6, N7
Light/Surge voltage suppressor
(Cable assembly)Min. bending radius 20mm
Block separation lever
P1
5 3 E
PE
x
PE
X
12
3
4 5
67
89
10
111213
1415
1617
18 1920
212223
2425 26
22.3 P = 10.5
(4.9
)
(C6:
3.2
)(N
7: 7
)
19.7
48
10
23
63
12.6
28.6
13.5
8
45.5
59
42.3
16.6
58.4
36.9
5.5
1828
.883
.792.2
45.6
18.1 8.4
L3
L1
L2 5
35(L4)
(81)(when circular connector is mounted)
7.5
(DIN
rai
l dim
ensi
on)
37.2
59.6
Manual overridePress and turn forthe locking type.
Silencer (air discharge port)(with built-in silencer specification)
4(A) port side: Orange2(B) port side: Green
Manifold
Specification SheetsV
alve Manifold
Specifications
Flat Ribbon C
ableS
ing
le Valve
Su
b-p
lateD
-sub
Co
nn
ector
EX
250E
X120
Circu
larC
on
necto
rE
X500
Valve M
anifo
ldC
om
mo
nS
pecificatio
ns
1in = 25.4mm
(mm)
48 ®
Series SV Circular Connector
Dimensions: Series SV2000 for Circular Connector
( )
UDB
• Cassette base manifold: SS5V2-W16CD- Stations
(S, R, RS) -
L1L2L3L4
L n 2160.5150 135.3 12.5
5210.5200 183.3 13.5
6223 212.5199.312
7248 237.5215.3 16.5
8260.5250 231.3 14.5
9273 262.5247.313
10298 287.5263.3 17.5
11310.5300 279.3 15.5
12323 312.5295.314
13335.5325 311.312
14360.5350 327.3 16.5
15373 362.5343.315
16385.5375 359.313
17410.5400 375.3 17.5
18423 412.5391.316
19435.5425 407.314
20448 437.5423.3 12.5
4198 187.5167.3 15.5
3185.5175 151.317
L dimensions n: Stations
• When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged. • External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.
C4, N3C6, N7C8, N9
(Station n) (Station 1)
(Rail mounting hole pitch: 12.5)
One-touch fitting[1(P), 3/5(E) port]Applicable tubing O.D.: ø10
N11
One-touch fitting[4(A), 2(B) port]Applicable tubing O.D.: ø4, N3
ø6, N7ø8, N9
(Pitch)P = 16
DIN rail holding screw
With external pilot specification
U side D side
One-touch fitting[PE: Pilot EXH port]Applicable tubing O.D.: ø4
N3
One-touch fitting[X: External pilot port]Applicable tubing O.D.: ø4
N3
Notch(to align connector position)
Light/Surge voltage suppressor
(Cable assembly)Min. bending radius 20mm
Block separation lever
A
B
A
B
P1
E3/5
P1
E3/5
12
3 4 5
67
89
10
11121314
1516
1718 19
2021
2223
2425 26
P1
E3/5
P1
E3/5
PE
x
PE
X
A
B
AB
A
B
AB
A
B
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
19.7
56.571
.5
5.5
27.3
39.5
35
102.
911
5.5
23.5
12.5
15.9
31.5
34.6
17.5
L2
L1
5
42.3
16.6
69.1
53.9
67.5
8
56.3
(5.3
)
18.8 9.5
43.1
37.2
51.3
L3 (L4)
7.5
(DIN
rai
l dim
ensi
on) (81)
(when circular connector is mounted)
60.8
(4.9
)
44.5
Manual overridePress and turn forthe locking type.
Silencer (air discharge port)(with built-in silencer specification)
4(A) port side: Orange2(B) port side: Green
1in = 25.4mm
(mm)
49®
Dimensions: Series SV1000 for Circular Connector
Circular Connector Series SV
( )
UDB
C3, N1C4, N3C6, N7
• Tie-rod base manifold: SS5V1-W10CD - Stations (S, R, RS) -• When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged. • External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.
L1L2L3L4L5
L n 2148 137.5116.316 63
5173 162.5147.8 12.5 94.5
6185.5175 158.3 13.5105
7198 187.5168.8 14.5115.5
8210.5200 179.3 15.5126
9223 212.5189.8 16.5136.5
10235.5225 200.3 17.5147
11235.5225 210.8 12.5157.5
12248 237.5221.3 13.5168
13260.5250 231.8 14.5178.5
14273 262.5242.3 15.5189
15285.5275 252.8 16.5199.5
16298 287.5263.3 17.5210
17298 287.5273.812
220.5
18310.5300 284.313
231
19323 312.5294.814
241.5
20335.5325 305.315
252
4160.5150 137.3 11.584
3160.5150 126.817
73.5
L dimensions n: Stations
(-D)
A
B
A
B
A
B
A
B
A
B
AB
AB
B 2
A 4
B 2 B 2 B 2 B 2
A 4 A 4 A 4 A 4
DIN rail holding screw(for DIN rail mounting)
(Station n) (Station 1)
(Rail mounting hole pitch: 12.5)
(Pitch)P = 10.5
One-touch fitting[1(P), 3/5(E) port]Applicable tubing O.D.: ø10
N9
One-touch fitting[4(A), 2(B) port]Applicable tubing O.D.: ø3.2, N1
ø4, N3ø6, N7
Notch(to align connector position)
1 P
3/5 E 3/5
1 P
E
12
3
4 5
67
89
10
111213
1415
1617
18 19
2021
2223
2425 26
E
1 P
35
B 2
A 4
B 2 B 2 B 2 B 2
A 4 A 4 A 4 A 4
1 P
5 3 E
One-touch fitting[PE: Pilot EXH port]Applicable tubing O.D.: ø4
N3
One-touch fitting[X: External pilot port]Applicable tubing O.D.: ø4
N3
U side D side
4-ø4.3(for mounting)
(Cable assembly)Min. bending radius 20mm
Light/Surge voltage suppressor
PE
X
PE
x
With external pilot specification
83.792
.2
18.3
1045
.59.
523
59.5
13.5
8.6
24.6
L5
38.4
27.5
(81)(when circular connector is mounted)
L3
L2
L1
5.5
(7.5
)
60.6
(4.9
)
(C6:
3.2
)(N
7: 7
)
35
4356
.5
11.8
(for
DIN
rai
l mou
ntin
g)83
4.6
8
(L4)
29.6
10.8
39.6
58.9
47.892
.6
14.1 8.4
5
8.9Manual override
Press and turn forthe locking type.
Silencer (air discharge port)(with built-in silencer specification)
4(A) port side: Orange2(B) port side: Green
Manifold
Specification SheetsV
alve Manifold
Specifications
Flat Ribbon C
ableS
ing
le Valve
Su
b-p
lateD
-sub
Co
nn
ector
EX
250E
X120
Circu
larC
on
necto
rE
X500
Valve M
anifo
ldC
om
mo
nS
pecificatio
ns
1in = 25.4mm
(mm)
50 ®
Series SV Circular Connector
Dimensions: Series SV2000 for Circular Connector
( )
UDB
C4, N3C6, N7C8, N9
• Tie-rod base manifold: SS5V2-W10CD - Stations (S, R, RS) -• When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged. • External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.
L1L2L3L4L5
L n 2160.5150 132.214 80
5210.5200 180.215
128
6223 212.5196.2 13.5144
7235.5225 212.2 11.5160
8260.5250 228.216
176
9273 262.5244.2 14.5192
10285.5275 260.2 12.5208
11310.5300 276.217
224
12323 312.5292.2 15.5240
13335.5325 308.2 13.5256
14348 337.5324.212
272
15373 362.5340.2 16.5288
16385.5375 356.2 14.5304
17398 387.5372.213
320
18 423 412.5388.2 17.5336
19435.5425 404.2 15.5352
20448 437.5420.214
368
4198 187.5164.217
112
3173 162.5148.2 12.596
L dimensions n: Stations
(-D)
Manual overridePress and turn forthe locking type.
Silencer (air discharge port)(with built-in silencer specification)
4(A) port side: Orange2(B) port side: Green
P1
E3/5
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
(Station n) (Station 1)
DIN rail holding screw(for DIN rail mounting)
(Rail mounting hole pitch: 12.5)
One-touch fitting[1(P), 3/5(E) port]Applicable tubing O.D.: ø10
N11
One-touch fitting[4(A), 2(B) port]Applicable tubing O.D.: ø4, N3
ø6, N7ø8, N9
A
B
AB
AB
4-ø5.3(for mounting)
U side D side
Notch(to align connector position)
P1
E3/5
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
B
A
2
4
1 P
E3/5
One-touch fitting[PE: Pilot EXH port]Applicable tubing O.D.: ø4
N3
One-touch fitting[X: External pilot port]Applicable tubing O.D.: ø4
N3
A
B
A
B
A
B
A
B
Light/Surge voltage suppressor
(Cable assembly)Min. bending radius 20mm
With external pilot specification
1 P
E3/5
PE
x
PE
X
12
3
4 5
67
89
10
11121314
15
1617
18 1920
212223
2425 26
1252
.563.5
115.
5
(4.9
)
L5
20.5
9.2
25.2
17.5(Pitch)P = 16
11.8
(for
DIN
rai
l mou
ntin
g)11
.9
30.6
(7.5
)
29.5
40.8
97.5
5.4
5.5
35
8
49.9
63.5
29.6
12.2
11.4
58.9 10
9.4
(5.3
)
53.4
102.
9
15.8 9.5
46.2
L3 (L4)
L2 5
L1
(80.9)(when circular connector is mounted)
60.7
1in = 25.4mm
(mm)
51®
Dimensions: Series SV3000 for Circular Connector
Circular Connector Series SV
( )
UDB
C6, N7C8, N9C10, N11
• Tie-rod base manifold: SS5V3-W10CD - Stations (S, R, RS) -• When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged. • External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.
L1L2L3L4L5
L n 2173 162.5147.8 12.597
5235.5225 209.313
158.5
6260.5250 229.8 15.5179
7285.5275 250.3 17.5199.5
8298 287.5270.8 13.5220
9323 312.5291.316
240.5
10335.5325 311.812
261
11360.5350 332.314
281.5
12385.5375 352.8 16.5302
13398 387.5373.3 12.5322.5
14423 412.5393.8 14.5343
15448 437.5414.317
363.5
16460.5450 434.813
384
17485.5475 455.315
404.5
18510.5500 475.8 17.5425
19523 512.5496.3 13.5445.5
20548 537.5516.8 15.5466
4223 212.5188.817
138
3198 187.5168.315
117.5
L dimensions n : Stations
(-D)
Manual overridePress and turn forthe locking type.
Silencer (air discharge port)(with built-in silencer specification)
4(A) port side: Orange2(B) port side: Green
(Station n) (Station 1)
DIN rail holding screw(for DIN rail mounting)
(Rail mounting hole pitch: 12.5)
One-touch fitting[1(P), 3/5(E) port]Applicable tubing O.D.: ø12
N11
4-ø5.3(for mounting)
U side D side
One-touch fitting[4(A), 2(B) port]Applicable tubing O.D.: ø6, N7
ø8, N9ø10, N11
One-touch fitting[X: External pilot port]Applicable tubing O.D.: ø6
N7
One-touch fitting[PE: Pilot EXH port]Applicable tubing O.D.: ø6
N7
Notch(to align connector position)
Light/Surge voltage suppressor
(Cable assembly)Min. bending radius 20mm
With external pilot specification
E
1 P
35
2 B
4 A
2 B
4 A
2 B
4 A
2 B
4 A
2 B
4 A E
1 P
35
AB
A
B
A
B
A
B
A
B
12
3 4 5
67
89
10111213
1415
1617
18 1920
212223
2425 26
E
1 P
35
2 B
4 A
2 B
4 A
2 B
4 A
2 B
4 A
2 B
4 A E
1 P
35
AB
A
B
x PE X PE
1263
.882.7
115.
812
8.8
L2
L1
5
21.3(Pitch)P = 20.523.5
13.5
36.1
8
83.8
5
(5.1
)
5.5
11.6
37.6
14.7
(for
DIN
rai
l mou
ntin
g) (10)
35
60.3
76.8
14.3
29.646
.9
58.9
10.1
(5.3
)
18 11
42.8
39.6
(81)(when circular connector is mounted)
L5 44.3
L3 (L4)
61.3
Manifold
Specification SheetsV
alve Manifold
Specifications
Flat Ribbon C
ableS
ing
le Valve
Su
b-p
lateD
-sub
Co
nn
ector
EX
250E
X120
Circu
larC
on
necto
rE
X500
Valve M
anifo
ldC
om
mo
nS
pecificatio
ns
1in = 25.4mm
(mm)
52 ®
Series SV Circular Connector
Dimensions: Series SV4000 for Circular Connector
( )
UDB
• Tie-rod base manifold: SS5V4-W10CD - Stations (S, R, RS) -• When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged. • External pilot port positions and silencer discharge port positions are the same as P, E port outlet positions.
L1L2L3L4L5
L n 2198 187.5162.8 17.5109
5260.5250 234.813
181
6285.5275 258.8 13.5205
7310.5300 282.814
229
8335.5325 306.8 14.5253
9360.5350 330.815
277
10385.5375 354.8 15.5301
11410.5400 378.8
16325
12435.5425 402.8 16.5349
13460.5450 426.817
373
14485.5475 450.8 17.5397
15498 487.5474.8 11.5421
16523 512.5498.8
12445
17548 537.5522.8 12.5469
18 573 562.5546.8
13493
19598 587.5570.8 13.5517
20623 612.5594.8
14541
4235.5225 210.8 12.5157
3210.5200 186.812
133
L dimensions n: Stations
02,03,
N9,N11,
C8,C10,C12,
(-D)
(Pitch)P = 24
U side D side
One-touch fitting[1(P), 3/5(E) port]Applicable tubing O.D.: ø12
N11One-touch fitting[4(A), 2(B) port]Applicable tubing O.D.: ø8, N9
ø10, N11ø12
DIN rail holding screw(for DIN rail mounting)
4-ø6.2(for mounting)
(Rail mounting hole pitch: 12.5)
Light/Surge voltage suppressor(Station n) (Station 1)
(Cable assembly)Min. bending radius 20mm
With external pilot specification
Notch(to align connector position)
One-touch fitting[X: External pilot port]Applicable tubing O.D.: ø6
N7
One-touch fitting[PE: Pilot EXH port]Applicable tubing O.D.: ø6
N7
[for
Rc
1/4,
3/8
]
Rc 1/4, 3/8[4(A), 2(B) port]
Rc 3/8[1(P), 3(E) port]
B
A
B
A
B
A
B
A
AB
B
A
AB
P1
E3/5
P1
E3A
B2
4 A
B2
4 A
B2
4 A
B2
4 A
B2
4
12
3 4 5
67
89
10111213
1415 16
1718 19
2021
2223
2425 26
P1
E3/5
P1
E3A
B2
4 A
B2
4 A
B2
4 A
B2
4 A
B2
4
x PE X PE
24
14.5
35
(5.4
)
L5
8
17.5
29.6
56.3
98.2
148.
216
4.7
81.7
75
16.2
61.885
.514
.7(fo
r DIN
rail
mou
ntin
g)
5
65.8
13.7
35.8
L2
L1
47.3
L3 (L4)
5.5
35
(10) (84.5)
(when circular connector is mounted)
33.8
41.6
11
58.3
74.8
2025
13.3
Manual overridePress and turn forthe locking type.
Silencer (air discharge port)(with built-in silencer specification)
4(A) port side: Orange2(B) port side: Green
1in = 25.4mm
(mm)