commonwealth of pennsylvania department of …foundation design parameters (site specific)...
TRANSCRIPT
BD-676MREFERENCE DRAWINGS
BD-677M
SHEET TITLE
INDEX OF SHEETS
SHT.NO.
4
2
1
3
GENERAL NOTES - 1
GENERAL NOTES - 2
GENERAL NOTES
BD-678M
SHEET 1 OF 6
GENERAL NOTES - 1
STANDARD
GROUND MOUNTED SOUND BARRIERS
PRECAST CONCRETE PANELS
BC-736M REINFORCEMENT BAR FABRICATION DETAILS
BC-779M STRUCTURE MOUNTED SOUND BARRIER WALLS
GROUND MOUNTED SOUND BARRIERS - STEEL POSTS
GROUND MOUNTED SOUND BARRIERS -
PRECAST CONCRETE POSTS
BC-776MGROUND MOUNTED SOUND BARRIERS -
PRECAST CONCRETE PANELS
DESIGN TABLE NOTES
BC-778M GROUND MOUNTED SOUND BARRIERS - STEEL POSTS
BC-777MGROUND MOUNTED SOUND BARRIERS -
PRECAST CONCRETE POSTS
BD-679M STRUCTURE MOUNTED SOUND BARRIER WALLS
5
GEOMETRY AND LAYOUT - 1
GEOMETRY AND LAYOUT - 2
MATERIAL NOTES
PRECAST CONCRETE PANEL DETAILS - 1
6 PRECAST CONCRETE PANEL DETAILS - 2
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE NOTED. U.S. CUSTOMARY UNITS
IN ( ) PARENTHESIS.
2. ALL "DESIGN" METRIC UNITS INDICATED ARE SOFT CONVERTED FROM U.S. CUSTOMARY UNITS.
3. DESIGN SPECIFICATIONS:
PENNDOT DESIGN MANUAL PART 4, STRUCTURES.
1989 AASHTO "GUIDE SPECIFICATIONS FOR STRUCTURAL DESIGN OF SOUND BARRIERS",
INCLUDING THE 1992 AND 2002 INTERIMS.
1992 AASHTO "STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES", 15TH EDITION,
INCLUDING THE 1993 AND 1994 INTERIMS.
2001 AASHTO "STANDARD SPECIFICATIONS FOR STRUCTURAL SUPPORTS FOR HIGHWAY
SIGNS, LUMINARIES AND TRAFFIC SIGNALS", 4TH EDITION, INCLUDING THE 2002
AND 2003 INTERIMS.
DESIGN IS IN ACCORDANCE WITH THE WORKING STRESS DESIGN METHOD. (NO INCREASE
IN ALLOWABLE UNIT STRESSES ARE PERMITTED EXCEPT FOR GROUP III LOADINGS
WHICH PERMITS A 33% OVERSTRESS.)
4. CONSTRUCTION SPECIFICATIONS AND WORKMANSHIP:
PROVIDE MATERIALS AND PERFORM WORK IN ACCORDANCE WITH THE CURRENT VERSION
OF THE PENNSYLVANIA DEPARTMENT OF TRANSPORTATION PUBLICATION 408,
AASHTO/AWS/D1.5M/D1.5 2002 - BRIDGE WELDING CODE AND THE CONTRACT SPECIAL
PROVISIONS. (USE AWS/D1.1/D1.1M 2002 FOR WELDING NOT COVERED IN
AASHTO/AWS/D1.5M/D1.5 2002.)
5. DESIGN LOADS:
WIND LOAD:
THE WIND LOAD INCLUDES A GUST FACTOR OF 1.3 AND A DRAG FACTOR OF 1.2
AND IS BASED ON A MAXIMUM 50-YEAR MEAN WIND VELOCITY AT 9144 mm (30’-0")
ABOVE THE GROUND SURFACE OF 130 km/hr (80 mph).
PRECAST CONCRETE PANELS ARE DESIGNED FOR A WIND PRESSURE OF 1.34 kPa
(28 PSF).
ICE LOAD: 0.14 kPa (3 PSF) APPLIED TO ONE SIDE OF PANEL AND POST.
SEISMIC LOAD: SEISMIC ACCELERATION COEFFICIENT "A" EQUAL TO 0.15.
6. WALL HEIGHTS MUST EQUAL OR EXCEED THE ACOUSTICAL PROFILE.
7. PANEL HEIGHTS:
610 mm (2’-0") MINIMUM TO 2743 mm (9’-0") MAXIMUM
PROVIDE STACKED PANELS WHEN THE WALL HEIGHT EXCEEDS 2743 mm (9’-0")
8. HORIZONTAL PANEL JOINTS:
MINIMIZE THE NUMBER OF HORIZONTAL PANEL JOINTS.
PROVIDE UNIFORM STEPS.
IF STEPS ARE REQUIRED, THE ELEVATION DIFFERENCE BETWEEN ADJACENT PANELS
IS NOT PERMITTED TO BE LESS THAN 150 mm (6") OR GREATER THAN 610 mm (2’-0").
9. GROUND MOUNTED SOUND BARRIER WALLS MUST BE PROTECTED BY CONCRETE BARRIERS UNLESS
THE WALL IS LOCATED BEYOND THE HORIZONTAL CLEAR ZONE OR IF THE BOTTOM OF PANELS
ARE A MINIMUM OF 1500 mm (5’-0") ABOVE THE EDGE OF PAVEMENT.
10. ALL REINFORCEMENT STEEL BARS AND WELDED WIRE FABRIC SHOWN ARE SOFT CONVERTED
METRIC SIZES.
11. PROVIDE EPOXY COATED OR GALVANIZED REINFORCEMENT BARS IN THE PANELS WHERE THE
WALL IS WITHIN 4300 mm (14’-0") OF THE EDGE OF TRAVEL LANE. EPOXY COATED OR
GALVANIZED REINFORCEMENT MAY BE REQUIRED IF FUTURE WIDENING IS ANTICIPATED.
12. ALL DIMENSIONS SHOWN ARE HORIZONTAL, EXCEPT AS NOTED.
13. DIMENSIONS SHOWN ARE FOR A NORMAL TEMPERATURE OF 20 DEGREES C (68 DEGREES F).
14. REINFORCEMENT IN SOME SECTIONS IS NOT SHOWN FOR CLARITY.
15. FOR ADDITIONAL INFORMATION REFER TO BC-776M.
1. REFER TO BC-776M FOR MATERIAL NOTES.
1. DESIGN TABLES SHOWN FOR THE PRECAST CONCRETE PANELS ARE DEVELOPED FOR
A WIND PRESSURE OF 1.34 kPa (28 PSF). USE THE INFORMATION SHOWN IN THE
TABLES FOR ALL HEIGHT ZONES.
2. THE DESIGN POST SPACING (CENTER TO CENTER OF POST)IS TO BE THE ACTUAL
POST SPACING ROUNDED UP TO THE NEXT HIGHEST INCREMENT OF POST SPACING
SHOWN ON THE DESIGN TABLES.
3. THE DESIGN WALL HEIGHT IS TO BE THE ACTUAL WALL HEIGHT ROUNDED UP TO
THE NEXT HIGHEST INCREMENT OF WALL HEIGHT SHOWN ON THE DESIGN TABLES.
4. THE DESIGN PANEL HEIGHT IS TO BE THE ACTUAL PANEL HEIGHT ROUNDED UP TO
THE NEXT HIGHEST INCREMENT OF PANEL HEIGHT SHOWN ON THE DESIGN TABLES.
5. PANEL HEIGHTS ARE PERMITTED TO BE ANY DIMENSION REQUIRED, BUT ARE NOT
PERMITTED TO BE LESS THAN 610 mm (2’-0") OR GREATER THAN 2743 mm (9’-0").
COMMONWEALTH OF PENNSYLVANIADEPARTMENT OF TRANSPORTATION
BUREAU OF DESIGN
NOTE: EITHER ALL METRIC OR ALL ENGLISH VALUES
MUST BE USED ON PLANS. METRIC AND
ENGLISH VALUES SHOWN MAY NOT BE MIXED.
CHIEF BRIDGE ENGINEER
RECOMMENDEDRECOMMENDED
DIRECTOR, BUREAU OF DESIGN
SEPT. 20, 2010 SEPT. 20, 2010
NOTES TO DESIGNER
GENERAL NOTES - 2
BD-676M
DESIGN PARAMETERS
SHEET 2 OF 6
STANDARD
GROUND MOUNTED SOUND BARRIERS
PRECAST CONCRETE PANELS
1. PRECAST CONCRETE PANELS:
PANELS ARE DESIGNED FOR WIND PRESSURE EQUAL TO 1.34 kPa (28 PSF).
PANELS ARE DESIGNED USING A 127 mm (5 INCH) STRUCTURAL THICKNESS.
PANELS ARE DESIGNED FOR AN ADDITIONAL CONCRETE WEIGHT OF 38 mm (1�INCH)
TO ACCOUNT FOR ARCHITECTURAL SURFACE TREATMENTS.
THE AVERAGE ARCHITECTURAL SURFACE TREATMENT THICKNESS, PER SIDE OF
PANEL, IS PERMITTED TO VARY FROM 0 TO 38 mm (1�INCH) BUT THE TOTAL
AVERAGE ARCHITECTURAL SURFACE TREATMENT THICKNESS, ON BOTH SIDES
OF THE PANEL, MUST NOT BE GREATER THAN 38 mm (1�INCH).
DESIGN CALCULATIONS ARE REQUIRED FOR PANELS WHICH HAVE A TOTAL AVERAGE
ARCHITECTURAL SURFACE TREATMENT GREATER THAN 38 mm (1�INCH).
PANELS ARE DESIGNED AS SIMPLY SUPPORTED BEAMS SPANNING BETWEEN POSTS.
PANELS ARE DESIGNED USING A 305 mm (1’-0") STRIP WIDTH.
PANELS ARE DESIGNED FOR THE FOLLOWING IN ACCORDANCE WITH THE PCI DESIGN
HANDBOOK, 5th EDITION, 1999:
PANELS ARE DESIGNED FOR STRIPPING FORCES CAUSED BY FORM SUCTION AND
IMPACT WHEN THE PANELS ARE STRIPPED FROM THE FORMS IN ACCORDANCE WITH
SECTION 5.2.3 AND TABLE 5.2.1 USING AN EQUIVALENT STATIC LOAD MULTIPLIER
EQUAL TO 1.50.
PROVIDE A MINIMUM CONCRETE STRENGTH, AT TIME OF STRIPPING, EQUAL
TO 27.6 MPa (4,000 PSI).
PANEL THICKNESS AND REINFORCING IS DESIGNED FOR STRIPPING AND LIFTING AT
TOP OF PANEL USING A TWO-POINT PICK-UP OR FOUR-POINT PICK-UP IN ACCORDANCE
WITH FIGURE 5.2.4.
PANELS ARE DESIGNED FOR TRANSPORTATION IN ACCORDANCE WITH SECTION
5.2.11 AND TABLE 5.2.1 USING AN EQUIVALENT STATIC LOAD MULTIPLIER EQUAL
TO 1.50.
THE FLEXURAL TENSILE STRESSES IN THE CONCRETE ARE CALCULATED USING
THE UNCRACKED GROSS SECTION BASED ON THE STRUCTURAL THICKNESS.
THE STRESSES ARE COMPARED AGAINST THE MODULUS OF RUPTURE REDUCED
BY A SAFETY FACTOR OF 1.50 IN ACCORDANCE WITH SECTION 5.2.4.1.
PANELS ARE NOT DESIGNED FOR TRAFFIC IMPACT LOADING.
ARCHITECTURAL SURFACE TREATMENTS
1. THE FOLLOWING ARCHITECTURAL SURFACE TREATMENTS ARE PERMITTED ON THE FACE
OF THE PRECAST CONCRETE PANELS AND ARE TO BE INDICATED ON THE CONTRACT DRAWINGS
AND IN THE CONTRACT SPECIAL PROVISIONS IF REQUIRED:
NON-FORM LINER FINISHES:
SMOOTH FINISH
BROOMED FINISH
FUZZY OR RAKED FINISH (PERMITTED ON ONE SIDE ONLY)
EXPOSED AGGREGATE
FORM LINER FINISHES:
ASHLAR STONE
CUT STONE
FRACTURE FIN
GRAPE STAKE
SHIP LAP
ANY OTHER TREATMENT PERMITTED BY THE DEPARTMENT
2. THE AVERAGE ARCHITECTURAL SURFACE TREATMENT THICKNESS, PER SIDE OF PANEL, IS
PERMITTED TO VARY FROM 0 TO 38 mm (1�INCH), BUT THE TOTAL AVERAGE ARCHITECTURAL
SURFACE TREATMENT, ON BOTH SIDES OF THE PANEL, MUST NOT BE GREATER THAN 38 mm
(1�INCH) UNLESS OTHERWISE INDICATED ON THE CONTRACT DRAWINGS.
3. FORM LINER ARCHITECTURAL SURFACE TREATMENTS ARE NOT RECOMMENDED ON THE PRECAST
CONCRETE POSTS.
4. AVOID USING FORM LINER FINISHES ON BOTH SIDES OF THE PRECAST CONCRETE PANELS.
A FORM LINER FINISH, ON ONE SIDE OF THE PANEL, ALONG WITH A STAMPED FINISH, ON
THE OTHER SIDE OF THE PANEL, IS PERMITTED.
COMMONWEALTH OF PENNSYLVANIADEPARTMENT OF TRANSPORTATION
BUREAU OF DESIGN
NOTE: EITHER ALL METRIC OR ALL ENGLISH VALUES
MUST BE USED ON PLANS. METRIC AND
ENGLISH VALUES SHOWN MAY NOT BE MIXED.
1. PREPARE CONTRACT DRAWINGS IN ACCORDANCE WITH THE DESIGN MANUAL, PART 4 AND
THESE STANDARDS.
2. THE FOLLOWING NOTE MUST BE PLACED ON THE DESIGN PLANS FOR SIGNATURE BY THE
DISTRICT ENVIRONMENTAL MANAGER INDICATING THAT THE DESIGN PLANS HAVE BEEN
REVIEWED AND ACCEPTED:
THE DISTRICT ENVIRONMENTAL MANAGER HAS REVIEWED AND
ACCEPTED THE ACOUSTIC REQUIREMENTS OF THE PROPOSED WALL.
DISTRICT ENVIRONMENTAL MANAGER
3. DETERMINE HEIGHT ZONE AND WIND PRESSURE REQUIRED FOR WALL DESIGN AND INDICATE
ON CONTRACT DRAWINGS.
4. DETERMINE ACCEPTABLE POST TYPE. PROVIDE EITHER PRECAST CONCRETE POSTS OR STEEL
POSTS. DO NOT MIX POST TYPES WITHOUT PERMISSION FROM THE DISTRICT BRIDGE ENGINEER.
5. SPECIFY IF THE REINFORCEMENT BARS ARE UNCOATED, EPOXY COATED OR GALVANIZED.
6. SPECIFY IF THE WELDED WIRE FABRIC IS UNCOATED, EPOXY COATED OR GALVANIZED.
7. PROVIDE A CONSTANT POST SPACING FOR THE ENTIRE LENGTH OF WALL. THE CONSTANT POST
SPACING MAY BE INTERRUPTED TO MISS DRAINAGE PIPES, UTILITIES, AND/OR ANY OTHER
PHYSICAL FEATURES. VARIATIONS MUST BE ACCEPTED BY THE DISTRICT BRIDGE ENGINEER.
8. GROUND MOUNTED SOUND WALLS MUST BE PROTECTED BY CONCRETE BARRIERS UNLESS THE WALL IS
LOCATED BEYOND THE HORIZONTAL CLEAR ZONE OR IF THE BOTTOM OF PANELS ARE A MINIMUM OF
1500 mm (5’-0") ABOVE THE EDGE OF PAVEMENT.
9. INDICATE IF THE TOP OF PANELS ARE STEPPED OR SLOPED. SLOPED PANELS ARE THE
PREFERRED OPTION FOR MOST ARCHITECTURAL SURFACE TREATMENTS.
10. THE FOLLOWING INFORMATION MUST BE SHOWN ON THE CONTRACT DRAWINGS (IF APPLICABLE):
OVERALL WALL LENGTH
HORIZONTAL GEOMETRY
VERTICAL GEOMETRY
ACOUSTIC PROFILE ELEVATIONS
EXISTING GROUND LINE ELEVATIONS
FINISHED GROUND LINE ELEVATIONS
GENERAL NOTES
FOUNDATION NOTES
STAKE-OUT PLAN
DETAILS
REINFORCEMENT BAR SCHEDULE FOR ALL CAST-IN-PLACE CONCRETE
ANY OTHER INFORMATION REQUIRED TO CONSTRUCT THE SOUND BARRIER WALL
11. THE FOLLOWING GEOTECHNICAL INFORMATION MUST BE INDICATED ON THE DESIGN PLANS:
PERMITTED FOUNDATION TYPES (SPREAD FOOTINGS AND/OR DRILLED CAISSONS)
FOUNDATION DESIGN PARAMETERS (SITE SPECIFIC)
APPROXIMATE TOP OF ROCK ELEVATIONS ALONG LENGTH OF WALL
APPROXIMATE GROUND WATER ELEVATIONS ALONG LENGTH OF WALL
TYPE OF SOIL TO DETERMINE CAISSON LENGTH IF NO FOUNDATION DESIGN PARAMETERS
ARE SPECIFIED
TOP AND BOTTOM CAISSON ELEVATIONS
TOP AND BOTTOM OF FOOTING ELEVATIONS
ANY OTHER INFORMATION REQUIRED TO CONSTRUCT THE SOUND BARRIER WALL
12. PROVIDE FIRE HYDRANT OPENINGS OR OTHER HIGHWAY ACCESS OPENINGS AS REQUIRED
IN THE PRECAST CONCRETE PANELS. PROVIDE REINFORCEMENT AROUND OPENINGS IN
ACCORDANCE WITH DETAILS SHOWN ON BC-776M TO PRECLUDE CRACKING.
13. SLOPE THE FINISHED GROUND LINE AWAY FROM THE SOUND BARRIER WALL.
14. INDICATE IF THE ARCHITECTURAL SURFACE TREATMENT TOLERANCES AS PROVIDED IN
PUBLICATION 408, SECTION 1086.3 ARE APPLICABLE.
15. THE FOLLOWING INFORMATION MUST BE SPECIFIED ON THE DESIGN PLANS OR INDICATED
IN THE CONTRACT SPECIAL PROVISIONS:
ARCHITECTURAL SURFACE TREATMENTS ON THE RESIDENTIAL AND ROADWAY SIDES
OF THE PRECAST CONCRETE SOUND BARRIER PANELS AND POSTS. INDICATE THE MINIMUM,
MAXIMUM AND AVERAGE DEPTHS. ARCHITECTURAL SURFACE TREATMENTS ARE NOT
RECOMMENDED ON PRECAST CONCRETE POSTS WITHOUT APPROVAL FROM THE DISTRICT
BRIDGE ENGINEER.
COLOR OF THE INTEGRAL PIGMENTATION FOR PRECAST CONCRETE SOUND BARRIER
PANELS AND THE PRECAST CONCRETE POSTS.
COLOR OF JOINT SEALANT AND/OR CAULKING COMPOUND, NON-SHRINK GROUT, AND
ANTIGRAFFITI COATING.
LIMITS OF ANTIGRAFFITI COATING.
PAINT COLOR OF STEEL COMPONENTS.
16. PROVIDE FEDERAL COLOR NUMBERS IN ACCORDANCE WITH FEDERAL STANDARD NUMBER
595A OR 595B.
17. PROVIDE COMPLETE DETAILS AND DESIGN, IF REQUIRED, WHERE A GROUND MOUNTED
SOUND BARRIER IS CONNECTED TO A STRUCTURE MOUNTED SOUND BARRIER. REFER TO
BD-679M FOR DETAILS.
18. DESIGN COMPUTATIONS AND DETAILS ARE REQUIRED FOR ANY PORTION OF THE STRUCTURE
FOR WHICH THE INFORMATION IS NOT TAKEN DIRECTLY FROM THE SOUND BARRIER STANDARDS.
19. SPECIFY IF A SOUND BARRIER ABSORPTIVE CONCRETE FACING IS REQUIRED ON THE FACE OF
THE PRECAST CONCRETE PANELS. SOUND ABSORPTIVE PANELS MUST BE APPROVED BY THE
DEPARTMENT USING THE NEW PRODUCT EVALUATION PROCESS. DESIGNER MUST PREPARE DESIGN
CALCULATIONS FOR THE FOUNDATIONS DUE TO THE INCREASED PANEL WEIGHT.
20. IF NEEDED DETAILS ARE NOT FOUND IN THE SOUND BARRIER STANDARDS A SPECIAL SUBMISSION
REQUESTING APPROVAL FOR SPECIFIC DETAILS MUST BE MADE TO THE CHIEF BRIDGE ENGINEER.
CHIEF BRIDGE ENGINEER
RECOMMENDEDRECOMMENDED
DIRECTOR, BUREAU OF DESIGN
SEPT. 20, 2010 SEPT. 20, 2010
BD-676M
CL PRECAST CONCRETE
OR STEEL POST
TRULY VERTICAL
CL PRECAST CONCRETE
OR STEEL POST
TRULY VERTICAL
DIFFERENCE IN PANEL HEIGHT
610 (2’-0") MAX. WHERE
INDICATED OR SPECIFIED
0 (0") MIN.
25 (1") MAX.
(TYP.)
EXISTING OR
PROPOSED
GROUND
LEVEL PANEL
GROUND MOUNTED SOUND BARRIER ELEVATION
(PRECAST CONCRETE POST SHOWN,
STEEL POST SIMILAR)
GALVANIZED LIFTING INSERT
(FILL WITH NON-SHRINK GROUT
AFTER INSTALLATION),
(COLOR TO MATCH POST) (TYP.)
EMBEDMENT
AS REQUIRED
BY DESIGN
12 (1/2") THICK (MIN.)
NEOPRENE BEARING PAD (TYP.)
A
A
SPREAD FOOTING
B
B
CAISSON
LIMIT OF
EXCAVATION
AND CAISSON
EMBEDMENT
AS REQUIRED
BY DESIGN
75 (3")
MAX. (TYP.)
140 (5�")
MIN. (TYP.)
END OF PANEL
LIMITS OF ARCHITECTURAL
SURFACE TREATMENT
(WHEN SPECIFIED)
(M
IN
.)
SECTION A-A
SECTION B-B
L
T
GROUND
TOP OF
GROUND
TOP OF
(3’-0")
(M
IN
.)
45
7
(1’-6")
ELEV. BELOW
FROST LINE
CL POST, PANEL,
AND CAISSON
CL POST, PANEL,
AND FOOTING
91
4
CD =
CAISSON
DIAMETER
NOTES:
SHEET 3 OF 6
PS = POST SPACING: 6096 (20’-0") MAX.
EDGE OF
POST
CL PANEL JOINT
(IF REQUIRED),
SEE DETAIL B ON
SHEET 6 OF BC-776M
(LEVEL)
TOP OF PANEL TO MATCH
OR EXCEED ACOUSTICAL
PROFILE. PROVIDE LEVEL
OR SLOPED PANELS AS
REQUIRED.
LEGEND:
GRADE GROUND TO DRAIN WATER AWAY FROM THE
WALL. FILL DEPTH ON EACH SIDE OF WALL TO
BE WITHIN 300 mm (1’-0") DIFFERANCE.
TOP OF
FOOTING
(LEVEL)
TOP OF
CAISSON
(LEVEL)
PRECAST
CONCRETE
PANELS
PRECAST
CONCRETE
PANELS
STANDARD
GROUND MOUNTED SOUND BARRIERS
PRECAST CONCRETE PANELS
TOP OF POST
LEVEL
(TYP.)
BOTTOM OF
PANEL (LEVEL)
(TYP.)
GEOMETRY AND LAYOUT -1
H =
WA
LL
HE
IG
HT
(S
EE
NO
TE
2)
H =
WA
LL
HE
IG
HT
(S
EE
NO
TE
2)
15
0 (6
")
MIN
. P
AN
EL
EM
BE
DM
EN
T
(S
EE
NO
TE
3)
1. FOR ADDITIONAL INFORMATION REFER TO NOTES
ON SHEETS 1 AND 2.
2. WALL HEIGHT IS DEFINED AS FOLLOWS:
POST WITH BASE PLATE: H = HEIGHT FROM
TOP OF BASE PLATE TO TOP OF WALL
POST WITHOUT BASE PLATE: H = HEIGHT
FROM TOP OF FOOTING/CAISSON TO
TOP OF WALL
3. PANEL EMBEDMENT MAY NEED TO BE INCREASED TO
ACCOMMODATE BASE PLATES AND ANCHOR BOLT
PROJECTIONS.
150 (6")MIN.PANEL
EMBEDMENT (TYP.)
(SEE NOTE 3)
ACOUSTICAL PROFILE
(TOP OF WALL)
(SEE GENERAL NOTE 6
ON SHEET 1)
H =
WA
LL
HE
IG
HT
AS
RE
QU
IR
ED
BY
DE
SIG
N
12
19
(4
’-0
") M
IN
.
91
44
(3
0’-0
") M
AX
.
(S
EE
NO
TE
2)
150 (6") MIN.
610 (2’-0")MAX.
(SEE GENERAL NOTE
8 ON SHEET 1)
OPTIONAL SLOPED BOTTOM PANEL ELEVATION
(USE IN PLACE OF RAISED PANEL SEAT)
EXISTING OR
PROPOSED
GROUND
SPREAD FOOTING
LIMITS OF ARCHITECTURAL
SURFACE TREATMENT
(WHEN SPECIFIED)
CAISSON
61
0
(2’-0")
MA
X.
150 (6")
MIN.
610
(2’-0")
MA
X.
LEVEL AS REQUIRED
BASED ON FOOTING
DIMENSIONS
61
0
(2’-0")
MIN
.
RAISED PANEL SEAT (TO
ACCOMMODATE CHANGES
IN GROUND ELEVATION)
150 (6") MIN.
610 (2’-0") MAX.
J =
CA
IS
SO
N L
EN
GT
H
(M
IN
.)
45
7
(1’-6")
OPTIONAL SLOPED PRECAST
CONCRETE PANEL (PREFERRED)
LEVEL OR SLOPED TOP PANEL
(SLOPED TOP PANEL PREFERRED)
LEVEL AS REQUIRED BASED ON
CAISSON/PEDESTAL DIMENSIONS
CL PANEL JOINT (IF REQUIRED),
SEE DETAIL B ON SHEET 6 OF
BC-776M (LEVEL)
150 (6") MIN.
(SEE NOTE 3)
OPTIONAL SLOPED PRECAST
CONCRETE PANEL
150 (6") MIN.
COMMONWEALTH OF PENNSYLVANIADEPARTMENT OF TRANSPORTATION
BUREAU OF DESIGN
NOTE: EITHER ALL METRIC OR ALL ENGLISH VALUES
MUST BE USED ON PLANS. METRIC AND
ENGLISH VALUES SHOWN MAY NOT BE MIXED.
CHIEF BRIDGE ENGINEER
RECOMMENDEDRECOMMENDED
DIRECTOR, BUREAU OF DESIGN
SEPT. 20, 2010 SEPT. 20, 2010
BD-676M
SHEET 4 OF 6
STANDARD
GROUND MOUNTED SOUND BARRIERS
PRECAST CONCRETE PANELS
SHOULDER
SECTION - GROUND MOUNTED
SOUND BARRIER WALL
ADJACENT TO ROADWAY BARRIER
600 (2’-0")
MIN.
CAISSON 150 (6")
(MIN.)
GUTTER LINE
SHOULDER
600 (2’-0")
MIN.
SLOPE TO
DRAIN
SLOPE TO
DRAIN
914 (3’-0")
(MIN.)
FOR CAISSON FOR SPREAD FOOTING
CL POST, PANEL,
AND CAISSON
CL POST, PANEL,
AND FOOTING
FACE OF POST FACE OF POST
1070
(3’-6")
MIN
.
1070
(3’-6")
MIN
.
GUTTER LINE
1070
(3’-6")
MIN
.
150
(6")
FACE OF
POST
FACE OF
PANELBOND BREAKER
(RDWY. ITEM)
20 (�") EXPANSION
JOINT MATERIAL
(RDWY. ITEM)
4%
100 (4") CLASS A
CONCRETE CAP
(RDWY. ITEM)
NO. 57 COARSE
AGGREGATE
(RDWY. ITEM)
WWF 152x152-MW19xMW19
(WWF 6x6-W2.9xW2.9)
(GALVANIZED)(RDWY. ITEM)
4%
FACE OF
POST
FACE OF
PANEL
OFFSET GREATER
THAN 1800 (6’-0")
SEE NOTE A
NOTES:
CONCRETE CAP DETAIL
SEE CONCRETE
CAP DETAIL
SEE CONCRETE
CAP DETAIL
600 (2’-0") MIN.
1800 (6’-0") MAX.
SEE NOTE A
NOTE A:
IF OFFSET IS GREATER THAN 1800 (6’-0")
CONCRETE CAP MAY BE ELIMINATED AND SUBSTITUTED
WITH PLANTINGS OR ROCK SLOPE PROTECTION.
ALTERNATE DETAILS MUST BE SUBMITTED TO THE
DISTRICT BRIDGE ENGINEER FOR ACCEPTANCE.
GEOMETRY AND LAYOUT - 2
50 (2") | WEEPHOLES
IN CENTER OF ROADWAY BARRIER
[MAX. SPACING 3000 (10’-0")]
SLOPE TO
DRAIN
CAISSON 150 (6")
(MIN.)
SLOPE TO
DRAIN
FOR CAISSON FOR SPREAD FOOTING
CL POST, PANEL,
AND CAISSON
CL POST, PANEL,
AND FOOTING
FACE OF POST FACE OF POST
SLOPE TO
DRAIN
(TYP.)
SINGLE FACE
CONCRETE BARRIER
(RDWY. ITEM)
SINGLE FACE
CONCRETE BARRIER
(RDWY. ITEM)
SECTION - GROUND MOUNTED
SOUND BARRIER WALL
ADJACENT TO ROADWAY BARRIER
SINGLE FACE
CONCRETE BARRIER
(RDWY. ITEM)
600 (2’-0")
MIN.
SHOULDER
600 (2’-0")
MIN.
SHOULDER
SINGLE FACE
CONCRETE BARRIER
(RDWY. ITEM)
1070
(3’-6")
MIN
.
GUTTER LINE
1070
(3’-6")
MIN
.
GUTTER LINE
SINGLE FACE
CONCRETE BARRIER
(RDWY. ITEM)
SINGLE FACE
CONCRETE BARRIER
(RDWY. ITEM)
SPREAD
FOOTING
AVOID CONFLICTS
BETWEEN FOOTING AND
CONCRETE BARRIER, INCREASE
CLEARANCE AS REQUIRED
SPREAD
FOOTING
AVOID CONFLICTS
BETWEEN FOOTING AND
CONCRETE BARRIER, INCREASE
CLEARANCE AS REQUIRED914 (3’-0")
(MIN.)
OPTION 1 (SEE NOTE 2) OPTION 2 (SEE NOTE 2)
CL POST, PANEL,
AND FOOTING/
CAISSON
CL POST, PANEL,
AND FOOTING/
CAISSON
1. FOR ADDITIONAL INFORMATION REFER TO NOTES
ON SHEETS 1 AND 2.
2. DESIGNER TO SELECT WHICH OPTION IS USED
BASED ON THE ROADWAY GEOMETRICS, RIGHT-OF-WAY
REQUIREMENTS AND ANY ADDITIONAL CONSTRAINTS.
OBTAIN ACCEPTANCE FROM THE DISTRICT BRIDGE
ENGINEER. (THE DEPARTMENT PREFERS OPTION 1
USING THE CONCRETE CAP.)
COMMONWEALTH OF PENNSYLVANIADEPARTMENT OF TRANSPORTATION
BUREAU OF DESIGN
NOTE: EITHER ALL METRIC OR ALL ENGLISH VALUES
MUST BE USED ON PLANS. METRIC AND
ENGLISH VALUES SHOWN MAY NOT BE MIXED.
CHIEF BRIDGE ENGINEER
RECOMMENDEDRECOMMENDED
DIRECTOR, BUREAU OF DESIGN
SEPT. 20, 2010 SEPT. 20, 2010
38 (1�")
CL
R. M
IN
.
BD-676M
2
2
2
2
WWF 6x6-W8xW4
WWF 6x6-W8xW4
WWF 6x6-W8xW8
WWF 6x4-W8xW12
3658
WWF 152x102-MW52xMW77
WWF 152x152-MW52xMW26
WWF 152x152-MW52xMW26
WWF 152x152-MW52xMW52
1219
1829
2438
610
2
2
4
2
WWF 4x6-W8xW4
WWF 4x6-W8xW4
WWF 4x6-W8xW8
WWF 4x4-W8xW12
2
2
4
4
WWF 6x6-W20xW4
WWF 6x6-W20xW4
WWF 6x6-W20xW8
4877
WWF 102x102-MW52xMW77
WWF 102x152-MW52xMW26
WWF 102x152-MW52xMW26
WWF 102x152-MW52xMW52
1219
1829
2438
610
6096
1219
1829
2438
610
12.0
16.0
20.0
2.0
4.0
6.0
8.0
2.0
4.0
6.0
8.0
2.0
4.0
6.0
8.0 WWF 6x4-W20xW12
WWF 152x152-MW130xMW26
WWF 152x152-MW130xMW26
WWF 152x152-MW130xMW52
WWF 152x102-MW130xMW77
U.S. CUSTOMARY UNITS
POST
SPACING
PS
(FT.)
PRECAST CONCRETE
PANEL REINFORCEMENT
MIN. NUMBER
OF LIFTING
INSERTS
PANEL
HEIGHT
PH
(FT.)
WELDED WIRE FABRIC
** WWF AxB-WCxWD
MIN. NUMBER
OF LIFTING
INSERTS
POST
SPACING
PS
(mm)
PANEL
HEIGHT
PH
(mm)
WELDED WIRE FABRIC
** WWF AxB-MWCxMWD
V
H
POST SIZE
5�
DIMENSION TABLE
U.S. CUSTOMARY UNITS
5�
6�
DIMENSION TABLE
METRIC UNITS
140
140
165
** WWF AxB-WCxWD (U.S. CUSTOMARY)
WWF AxB-MWCxMWD (METRIC)
WHERE A = SPACING OF HORIZONTAL BARS (S )
B = SPACING OF VERTICAL BARS (S )
C = HORIZONTAL WIRE SIZE
D = VERTICAL WIRE SIZE
WWF = WELDED WIRE FABRIC
PRECAST CONCRETE PANEL
PL = PANEL LENGTH
12 (�") CHAMFER (TYP.)
PRECAST CONCRETE PANEL
PLAN
RESIDENTIAL SIDE
ROADWAY SIDE
T=127 (5") MIN. STRUCTURAL
THICKNESS (ADDITIONAL
THICKNESS REQUIRED FOR
ARCHITECTURAL SURFACE
TREATMENTS)
STRAIGHT END
FLARED END ALTERNATE
25 (1") CLR.
(TYP.)
102 (4")
38 (1�")
CLR. (TYP.)
50 (2")
1
1
#13 (#4)
PERIMETER
REINFORCEMENT
(FORM LINER SIDE WHEN SPECIFIED)
#13 (#4)
PERIMETER
REINFORCEMENT
ELEVATION - SLOPED TOPELEVATION - LEVEL TOP
LEGEND:
END OF PANEL
25
(1")
DETAIL D
#13 (#4)
PERIMETER
REINFORCEMENT
PL = PANEL LENGTH
SV
SH
#13 (#4)
PERIMETER
REINFORCEMENT
(TYP.)
PH
= P
AN
EL
HE
IG
HT
PA
RT
IA
L H
EIG
HT
OR
FU
LL
HE
IG
HT
PA
NE
L
MIN
IM
UM
PA
NE
L H
EIG
HT
= 6
10 (
2’-0")
MA
XIM
UM
PA
NE
L H
EIG
HT
= 2
74
3 (
9’-0
")
ST
AC
KE
D P
AN
EL
S A
RE
NO
T P
ER
MIT
TE
D
WH
EN
TH
E W
AL
L H
EIG
HT
S A
RE
EQ
UA
L T
O
OR
LE
SS
TH
AN
27
43
(9
’-0
")
SH
SV
#13 (#4)
PERIMETER
REINFORCEMENT
(TYP.)
SEE
DETAIL D
SEE
DETAIL D
100 (4")
LEVEL
100 (4")
LEVEL
61
0 (2
’-0
") (M
IN
.)
610 (2’-0")
(M
AX
. S
TE
P)
NOTES:
PRECAST CONCRETE PRECAST CONCRETE
W8 (STEEL)
W10 (STEEL)
W12 (STEEL) 7� 190
W250 (STEEL)
W310 (STEEL)
W200 (STEEL)
HS = SPACING OF HORIZONTAL BARS
VS = SPACING OF VERTICAL BARS
GALVANIZED LIFTING INSERT (TYP.)
(SEE LIFTING INSERT LOCATION
DETAIL ON SHEET 4 OF BC-776M)
"X"
(IN.)
"X"
(TYP.)
SHEET 5 OF 6
TOP OF PANEL
(LEVEL)
#13 (#4) THRU
LIFTING INSERT
38
(1
�")
CL
R.
MIN
.
38 (1�")
CLR. (TYP.
ALL AROUND,
UNLESS NOTED
OTHERWISE)
BOTTOM
OF PANEL
(LEVEL)
BOTTOM
OF PANEL
(LEVEL)
38 (1�")
CLR. (TYP.
ALL AROUND,
UNLESS NOTED
OTHERWISE)
#13 (#4) THRU
LIFTING INSERT
38 (1�") CLR.
(UNLESS NOTED
OTHERWISE)
TIE (ALL
LOCATIONS)
50 (2") M
IN
.
127 (
5") M
AX
.
(PERMITTED FOR STEEL POSTS ONLY)
LAP
2 TIMES S MIN.V
ARCHITECTURAL SURFACE
TREATMENT (WHEN SPECIFIED)
(REFER TO DESIGN PARAMETERS
ON SHEET 2)
WIND PRESSURE = 28 PSF
PRECAST CONCRETE
PANEL REINFORCEMENT
METRIC UNITS
WIND PRESSURE = 1.34 kPa
4WWF 6x4-W8xW129.0
4WWF 4x4-W8xW129.0
49.0
WWF 152x102-MW52xMW772743
WWF 102x102-MW52xMW772743
WWF 152x102-MW130xMW772743
STANDARD
GROUND MOUNTED SOUND BARRIERS
PRECAST CONCRETE PANELS
POST SIZE"X"
(mm)
5�20" DIA. PIPE (STEEL) 508 mm DIA. (STEEL) 140
2
2
2
2
2
2
4
2
2
2
4
4
4
4
4
WWF 6x4-W20xW12
PL = PS (POST SPACING)
- WEB THICKNESS - 25 (1")
UNCOATED OR GALVANIZED
280 (11") MIN. (TYP.)
EPOXY COATED
410 (1’-4") MIN. (TYP.)
PL = PANEL LENGTH
PL = PS (POST SPACING)
- WEB THICKNESS - 25 (1")
PANEL LENGTH MAY NEED ADJUSTED TO
ACCOMMODATE ANGLED AND CORNER POSTS
PRECAST CONCRETE PANEL DETAILS - 1
VERTICALHORIZONTAL
WELDED WIRE STEEL
AREA (mm /m)2
HORIZONTAL VERTICAL
2
WELDED WIRE STEEL
AREA (in /ft)
0.16 0.08
0.16 0.08
0.16 0.16
0.16 0.36
0.16 0.36
0.24 0.08
0.40 0.08
0.24 0.08
0.24
0.24
0.24
0.40 0.08
0.40
0.40
0.40
0.16
0.36
0.36
0.16
0.36
0.36
342 171
510 171
855 171
342
342
342
342
510
510
510
510
855
855
855
855
171
171
171
342
755
755
342
755
755
342
755
755
TOP OF PANEL
(SLOPED)
SEE DIMENSION TABLE
UNLESS OTHERWISE SPECIFIED
50 (2") C
LR
.
(T
O W
WF
)
WELDED WIRE FABRIC
(WWF)
45^ CHAMFER
(OPTIONAL)(TYP.)
38 (1�") MIN.
CLR. TO #13 (#4)
BARS (TYP.)
WELDED WIRE
FABRIC (WWF)
(SEE TABLES)
1. FOR ADDITIONAL INFORMATION REFER TO NOTES
ON SHEETS 1 AND 2.
2. IF STACKED PANELS ARE REQUIRED REFER TO
DETAIL B ON SHEET 6 OF BC-776M.
3. DESIGNER TO SPECIFY THE WELDED WIRE FABRIC
REQUIREMENTS, INCLUDING THE AREA OF STEEL,
AND THE MINIMUM NUMBER OF LIFTING INSERTS
REQUIRED FOR ALL PANEL SIZES AS REQUIRED
ON THE CONTRACT DRAWINGS. INFORMATION IS
PERMITTED TO BE IN TABLE FORM SIMILAR TO
THE TABLES SHOWN..
WELDED WIRE
FABRIC (WWF)
(SEE TABLES)
WELDED WIRE
FABRIC (WWF)
(SEE TABLES)
WELDED WIRE FABRIC
(WWF)(SEE TABLES)
SEE PANEL NOTCH DETAILS
ON SHEET 6 (IF REQUIRED)
(TYP.)
COMMONWEALTH OF PENNSYLVANIADEPARTMENT OF TRANSPORTATION
BUREAU OF DESIGN
NOTE: EITHER ALL METRIC OR ALL ENGLISH VALUES
MUST BE USED ON PLANS. METRIC AND
ENGLISH VALUES SHOWN MAY NOT BE MIXED.
CHIEF BRIDGE ENGINEER
RECOMMENDEDRECOMMENDED
DIRECTOR, BUREAU OF DESIGN
SEPT. 20, 2010 SEPT. 20, 2010
38 (1�")
CL
R. M
IN
.
BD-676M
SHEET 6 OF 6
STANDARD
GROUND MOUNTED SOUND BARRIERS
PRECAST CONCRETE PANELS
PRECAST CONCRETE PANEL DETAILS - 2
610 (2’-0")
(M
AX
. S
TE
P)
PL = PANEL LENGTH
SV
#13 (#4) THRU
LIFTING INSERT
PL = PS (POST SPACING)
- WEB THICKNESS - 25 (1")
100 (4")
LEVEL
100 (4")
LEVEL
SEE
DETAIL D
#13 (#4)
PERIMETER
REINFORCEMENT
(TYP.)
38 (1�")
CLR. (TYP.
ALL AROUND,
UNLESS NOTED
OTHERWISE)S
H
610 (2’-0")
(M
AX
. S
TE
P)
610 (2’-0") +
S
TE
P (M
IN
.)
PH
= P
AN
EL
HE
IG
HT
PA
RT
IA
L H
EIG
HT
OR
FU
LL
HE
IG
HT
PA
NE
L
MIN
IM
UM
PA
NE
L H
EIG
HT
= 6
10 (
2’-0") +
ST
EP
S
MA
XIM
UM
PA
NE
L H
EIG
HT
= 2
74
3 (
9’-0
")
ST
AC
KE
D P
AN
EL
S A
RE
NO
T P
ER
MIT
TE
D
WH
EN
TH
E W
AL
L H
EIG
HT
S A
RE
EQ
UA
L T
O
OR
LE
SS
TH
AN
27
43
(9
’-0
")
PRECAST CONCRETE PANEL
WITH OPTIONAL SLOPED BOTTOM
ELEVATION - SLOPED TOP
CL POST AND
BASE PLATE
EDGE OF POST
PANEL NOTCH DETAIL
FOR BASE PLATE CONNECTIONS
EDGE OF PANEL
1
2
LEVEL
D+25 (1")
25 (1") MIN.
125 (5") MIN.
12 6
(�" �")
25 6
(1" �")
12 (�") THICK (MIN.)
NEOPRENE BRG. PAD
TOP OF CAISSON /
FOOTING (LEVEL)
DEPTH OF NOTCH =
D+38+t( 6)
D+1�"+t( �")
REINFORCEMENT DETAIL
FOR PANEL NOTCH
#13 (#4)
PERIMETER
REINFORCEMENT
(TYP.)
UNCOATED OR GALVANIZED
280 (11") MIN. (TYP.)
EPOXY COATED
410 (1’-4") MIN. (TYP.)
PL = PANEL LENGTH
PL = PS (POST SPACING)
- WEB THICKNESS - 25 (1")
SEE
DETAIL D
#13 (#4)
PERIMETER
REINFORCEMENT
(TYP.) 38 (1�")
CLR. (TYP.
ALL AROUND,
UNLESS NOTED
OTHERWISE)
SH
610 (2’-0")
(M
AX
. S
TE
P)
SV
TOP OF PANEL
(LEVEL)
#13 (#4) THRU
LIFTING INSERT
38
(1
�")
CL
R. M
IN
.
610 (2’-0") +
S
TE
P (M
IN
.)
ELEVATION - LEVEL TOP
LEGEND:NOTES:
S = SPACING OF HORIZONTAL BARSH
VS = SPACING OF VERTICAL BARS
WELDED
WIRE FABRIC
(WWF)
PANEL LENGTH MAY NEED ADJUSTED TO
ACCOMMODATE ANGLED AND CORNER POSTS
UNCOATED OR GALVANIZED
280 (11") MIN. (TYP.)
EPOXY COATED
410 (1’-4") MIN. (TYP.)
GALVANIZED LIFTING INSERT (TYP.)
(SEE LIFTING INSERT LOCATION
DETAIL ON SHEET 4 OF BC-776M)
GALVANIZED LIFTING INSERT (TYP.)
(SEE LIFTING INSERT LOCATION
DETAIL ON SHEET 4 OF BC-776M)
TOP OF PANEL
(SLOPED)
WELDED WIRE FABRIC
(WWF)(SEE TABLES
ON SHEET 5)
WELDED WIRE FABRIC
(WWF)(SEE TABLES
ON SHEET 5)
BOTTOM
OF PANEL
(SLOPED)
BOTTOM
OF PANEL
(SLOPED)
LEVEL AS REQUIRED
BASED ON FOOTING/CAISSON
DIMENSIONS (TYP.)
LEVEL AS REQUIRED
BASED ON FOOTING/CAISSON
DIMENSIONS (TYP.)
1. FOR ADDITIONAL INFORMATION REFER
TO NOTES ON SHEETS 1 AND 2.
2. FOR DETAIL D, REFER TO SHEET 5.
BOTTOM
OF PANEL
NOTCH
38 (1�") CLR. (TYP.
ALL AROUND, UNLESS
NOTED OTHERWISE)
(FOR DETAILS 1 AND 2)
(PRECAST POST SHOWN / STEEL POST SIMILAR)
D = ANCHOR BOLT DIAMETER
LENGTH AS
REQUIRED
25 6
(1" �")
TOP OF
BASE PLATE
(LEVEL)
t = BASE PLATE THICKNESS
SEE PANEL
NOTCH DETAILS
(IF REQUIRED)
(TYP.)
SEE PANEL
NOTCH DETAILS
(IF REQUIRED)
(TYP.)
NON-SHRINK GROUT
UNDER BASE PLATE
GROUT DEPTH = D+25 (1")
COMMONWEALTH OF PENNSYLVANIADEPARTMENT OF TRANSPORTATION
BUREAU OF DESIGN
NOTE: EITHER ALL METRIC OR ALL ENGLISH VALUES
MUST BE USED ON PLANS. METRIC AND
ENGLISH VALUES SHOWN MAY NOT BE MIXED.
CHIEF BRIDGE ENGINEER
RECOMMENDEDRECOMMENDED
DIRECTOR, BUREAU OF DESIGN
SEPT. 20, 2010 SEPT. 20, 2010