2019europump.com/images/catalog2019.pdf · communication protocol wyn-dart wyn-dart wyn-dart...

116
product catalog 2019

Upload: others

Post on 14-Oct-2019

160 views

Category:

Documents


21 download

TRANSCRIPT

Page 1: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

product catalog

2019

Page 2: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Actual products may vary from the ones presented in terms of shape, contents and/or dimensions because of changes of manufacturers.

All prices are EXW and do not include shipping or export costs. Europump® reserves the right to change prices any time.

For your orders and questions, please do not hesitate to contact us from our website: www.europump.com or our e-mail address: [email protected]

Page 3: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

about us

Europump® was founded in 1994 as a manufacturer of petroleum equipment. Today, Europump is one of the leading companies in classic and alternative fuel technologies, especially in LPG.

At Europump, our mission is to offer quality products that satisfy international safety and technical requirements while maintain affordable costs.

Our main production facilities are located in Milan-Italy and Istanbul- Turkey. We have Europump branches and distributors worldwide we can serve our customers with a wide range of products from our factories and our many partners.

Page 4: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

index

LPG

LPG Dispensers & Spare Parts 7

Skid Stations 23

Electronic Register 29

Mass Flow Meter 30

Flow Meters 31

Cylinder Filling Equipment 36

LPG Nozzles 38

Bypass Valve 40

LPG Pumps 41

ATEX Motors 49

Hose Reel 51

LPG Calibration 52

Conversion Systems 53

Fuel

Fuel Dispensers 54

Mobile Fuel Stations 59

Fuel Calibration 60

Automation Solutions

Station & Truck Automation 61

Automation 4.0 62

Station Control Panels 63

Page 5: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

index

Consoles 65

Level Gauges 66

Dial Level Indicators 69

Tank Gauging Systems

Gas Compressor Models 71

Compressors

Ball Valves 81

Check Valves 96

Strainers 97

Sight Glasses 98

Valves

Coupling Models 101

Couplings

Level Gauge Models 103

Level Gauges

Relief Valves 107

Excess Flow Valves 108

Pull-Away Valves 109

Valves

Gas Detectors 111

Gas Solenoid Valve 112

Gas Detection

Page 6: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame
Page 7: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Europump® has been producing LPG Dispensers since 1998. This experience makes our dispensers one of the best quality and reliable LPG dispensers in the market. Our dispenser series are stylish, modern, well designed and efficient.

Our dispenser line has several options to meet the technical and regulatory approval requirements of different countries. Stylish stainless steel or painted galvanize frames, IEC wiring methods to Zone 1 hazardous locations, with CE approved components, and special European approvals (like MID, PTB, ATEX and Gost) are available on select models.

• ATEX and MID Certificated design.

• Single, Dual or Quad nozzle configurations.

• Two different measurement technology options:- High accuracy and 4-piston Positive Displacement MT100B* meters (Made in Italy).

- “Coriolis mass flow meters**” (Made in Switzerland).

• Advanced electronic dispenser computer with backlit displays.

• Customer friendly field programming via alphanumeric keypad.

• Industry standard interface for automation systems.

• Automatic Temperature Compensation (ATC) according to ASTM tables.

• Electronic or mechanical calibration options.

• Volume, Amount or Mass** pre-programmed filling.

• Stainless steel or painted galvanize frame options.

• Optional MicroSDHC Card support for reports and logs.

• Optional Reciept Printer Support.

• Optional Multimedia Addons.

main features

lpg dispensers

7

Page 8: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

product code

V2-SI/P (painted)

V2-SI/SS (stainless)

product code

V2-SL/P (painted)

V2-SL/SS (stainless)

next generation LPG dispensers

venice lpg series

8

Page 9: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Eurostar E2-SL/P

lpg dispenserseurostar e series

product code

E2-SL/P (painted)

E2-SL/SS (stainless)

9

Page 10: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Eurostar En-SM multimedia series

eurostar e series

product code

E2-SM/P (painted)

E2-SM/SS (stainless)

10

Page 11: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Eurostar En-SL with Mass Flow Meter

Eurostar LPG dispenser with Mass Flow Meter provides the latest metering technology. Featuring high accuracy over an increased flow range, the meter lacks any moving parts; decreasing maintenance and calibration costs.

• Universally accepted Ex-approvals for hazardous areas.

• Maintenance-free meter operation: no moving parts or seals.

• Displays all the information you need during measuring like mass, volume, realtime density and temperature.

• Automatic Temperature Compensation according to ASTM tables.

• Maximum measuring accuracy: - Volume flow: 0.3% o.r. - Mass flow: 0.2% o.r.

• Compatible protocol with many forecourt automation solutions.

• Flexible process connections: fillings for cylinders or autogas.

main features

nozzle configuration pcs 1-2-4

size cm 45 x 100 x 185 (h)

number of displays pcs 2-4

technical specifications

lpg dispenserseurostar e series

11

Page 12: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

eurostar e series

gene

ral s

peci

ficat

ions

model E1-SL painted E1-SL stainless E2-SL painted

product code E1-SL/P E1-SL/SS E2-SL/P

main features

• ATEX, MID, GOST approval.• Stand-alone design (fully self contained electronics).• Single or dual nozzle configurations.• PTB approved long life positive displacement piston meter.• Italian design nozzles with safety breakaways.• Stainless steel or painted iron frames.• Interface availability with Wayne-Dart compatible automation systems.• Automatic Temperature Compensation (ATC).• International currency options available.• Double bobbine selenoid valves.• Mechanical and electronic calibration.• Available preset sales as volume or amount.• Multimedia modules - optional with extra cost.

power 220 - 380 V AC 50 hz 220 - 380 V AC 50 hz 220 - 380 V AC 50 hz

accuracy Max. ± %0.25 Max. ± %0.25 Max. ± %0.25

flow rate 5-50 l/min 5-50 l/min 5-50 l/min

humidity range 5 - 95% 5 - 95% 5 - 95%

temperature range -40 ˚C +55 ˚C -40 ˚C +55 ˚C -40 ˚C +55 ˚C

hydr

aulic

nozzles 1 1 2

meter MT-100 MT-100 MT-100

seperators 1 1 1

filters 1 1 1

elec

tron

ic

cpu per dispenser 1 1 1

cpu model Europump Pro-C4 Europump Pro-C4 Europump Pro-C4

number of displays 2 2 2

display digits 8x6x6 / 6x6x5 / module display 8x6x6 / 6x6x5 / module display 8x6x6 / 6x6x5 / module display

display per nozzle 2 2 1

additional display per nozzle - - optional

multimedia screen - - -

keyboard per dispenser 1 1 1

preset buttons per nozzle 2 2 2

ATC probe system 1 1 1

communication protocol Wyn-Dart Wyn-Dart Wyn-Dart

communication interface 2 wire current loop 2 wire current loop 2 wire current loop

fram

e

frame material painted galvanizestainless steel

painted galvanize

stainless steel side frames - -

dispenser size (unpacked) 48x104x185 cm 48x104x185 cm 48x110x185 cm

dispenser size (packed) 63x128x197 cm 63x128x197 cm 63x128x197 cm

net weight (unpacked) 143.60 kg 145.00 kg 178.00 kg

gross weight (packed) 195.00 kg 193.60 kg 228.00 kg

12

Page 13: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

lpg dispenserseurostar e series

gene

ral s

peci

ficat

ions

model E2-SL stainless E1-SL - MM painted E2-SL - MM painted

product code E-SL/SS E1-SL/P/MM E2-SL/P/MM

main features

• ATEX, MID, GOST approval.• Stand-alone design (fully self contained electronics).• Single or dual nozzle configurations.• PTB approved long life positive displacement piston meter.• Italian design nozzles with safety breakaways.• Stainless steel or painted iron frames.• Interface availability with Wayne-Dart compatible automation systems.• Automatic Temperature Compensation (ATC).• International currency options available.• Double bobbine selenoid valves.• Mechanical and electronic calibration.• Available preset sales as volume or amount.• Multimedia modules - optional with extra cost.

power 220 - 380 V AC 50 hz 220 - 380 V AC 50 hz 220 - 380 V AC 50 hz

accuracy Max. ± %0.25 Max. ± %0.20 Max. ± %0.20

flow rate 5-50 l/min 5-50 l/min 5-50 l/min

humidity range 5 - 95% 5 - 95% 5 - 95%

temperature range -40 ˚C +55 ˚C -40 ˚C +55 ˚C -40 ˚C +55 ˚C

note: can fill in liters or kilograms

hydr

aulic

nozzles 2 1 2

meter MT-100 Coriolis mass flow meter 8FE15

seperators 1 1 1

filters 1 1 1

elec

tron

ic

cpu per dispenser 1 1 1

cpu model Europump Pro-C4 Europump Pro-C4 Europump Pro-C4

number of displays 2 2 2

display digits 8x6x6 / 6x6x5 / module display module display module display

display per nozzle 1 2 1

additional display per nozzle optional - optional

multimedia screen - 19" 19"

keyboard per dispenser 1 1 1

preset buttons per nozzle 2 2 2

ATC probe system 1 1 1

communication protocol Wyn-Dart Wyn-Dart Wyn-Dart

communication interface 2 wire current loop 2 wire current loop 2 wire current loop

fram

e

frame materialstainless steel

painted galvanize painted galvanize

stainless steel side frames optional optional

dispenser size (unpacked) 48x110x185 cm 48x110x185 cm 48x110x185 cm

dispenser size (packed) 63x128x197 cm 63x128x197 cm 63x128x197 cm

net weight (unpacked) 176.40 kg 130.60 kg 138.60 kg

gross weight (packed) 226.40 kg 182.00 kg 220.00 kg

13

Page 14: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Eurostar T4-XL

Eurostar T4-XM

eurostar t series

product code

T2-XM(single nozzle each side)

T4-XM(dual nozzles each side)

product code

T2-XL(single nozzle each side)

T4-XL(dual nozzles each side)

14

Page 15: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

lpg dispenserseurostar t series

gene

ral s

peci

ficat

ions

model T1-SL T2-SL T2-XL

main features

• ATEX, MID, GOST approval.• Stand-alone design (fully self contained electronics).• Single or dual nozzle configurations.• PTB approved long life positive displacement piston meter.• Italian design nozzles with safety breakaways.• Stainless steel or painted iron frames.• Interface availability with Wayne-Dart compatible automation systems.• Automatic Temperature Compensation (ATC).• International currency options available.• Double bobbine selenoid valves.• Mechanical and electronic calibration.• Available preset sales as volume or amount.• Multimedia modules - optional with extra cost.

power 220 - 380 V AC 50 hz 220 - 380 V AC 50 hz 220 - 380 V AC 50 hz

accuracy Max. ± %0.25 Max. ± %0.25 Max. ± %0.25

flow rate 5-50 l/min 5-50 l/min 5-50 l/min

humidity range 5 - 95% 5 - 95% 5 - 95%

temperature range -40 ˚C / +55 ˚C -40 ˚C / +55 ˚C -40 ˚C / +55 ˚C

hydr

aulic

nozzles 1 2 2

meter MT-100 MT-100 MT-100

seperators 1 1 1

filters 1 1 1

elec

tron

ic

cpu per dispenser 1 1 1

cpu model Europump Pro-C4 Europump Pro-C4 Europump Pro-C4

number of displays 2 2 2

display digits 8x6x6 / 6x6x5 8x6x6 / 6x6x5 8x6x6 / 6x6x5

display per nozzle 2 1 1

additional display per nozzle optional optional optional

multimedia screen - - -

keyboard per dispenser 1 1 1

preset buttons per nozzle 2 2 2

ATC probe system 1 1 1

communication protocol Wyn-Dart Wyn-Dart Wyn-Dart

communication interface 2 wire current loop 2 wire current loop 2 wire current loop

fram

e

frame material painted galvanize painted galvanize painted galvanize

stainless steel side frames optional optional optional

dispenser size (unpacked) 70x95x234 cm 70x95x234 cm 70x123x234 cm

dispenser size (packed) 88x118x248 cm 88x118x248 cm 88x143x248 cm

net weight (unpacked) 230.60 kg 263.40 kg 303.00 kg

gross weight (packed) 290.60 kg 330.00 kg 358.00 kg

15

Page 16: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

lpg dispenserseurostar t series

gene

ral s

peci

ficat

ions

model T4-XL T2-XM T4-XM

main features

• ATEX, MID, GOST approval.• Stand-alone design (fully self contained electronics).• Single or dual nozzle configurations.• PTB approved long life positive displacement piston meter.• Italian design nozzles with safety breakaways.• Stainless steel or painted iron frames.• Interface availability with Wayne-Dart compatible automation systems.• Automatic Temperature Compensation (ATC).• International currency options available.• Double bobbine selenoid valves.• Mechanical and electronic calibration.• Available preset sales as volume or amount.• Multimedia modules - optional with extra cost.

power 220 - 380 V AC 50 hz 220 - 380 V AC 50 hz 220 - 380 V AC 50 hz

accuracy Max. ± %0.25 Max. ± %0.25 Max. ± %0.25

flow rate 5-50 l/min 5-50 l/min 5-50 l/min

humidity range 5 - 95% 5 - 95% 5 - 95%

temperature range -40 ˚C / +55 ˚C -40 ˚C / +55 ˚C -40 ˚C / +55 ˚C

hydr

aulic

nozzles 4 2 4

meter MT-100 MT-100 MT-100

seperators 2 1 2

filters 2 1 2

elec

tron

ic

cpu per dispenser 1 1 1

cpu model Europump Pro-C4 Europump Pro-C4 Europump Pro-C4

number of displays 4 2 4

display digits 8x6x6 / 6x6x5 8x6x6 / 6x6x5 8x6x6 / 6x6x5

display per nozzle 1 1 1

additional display per nozzle - optional -

multimedia screen - 32" 32"

keyboard per dispenser 1 1 1

preset buttons per nozzle 1 1 1

ATC probe system 1 1 1

communication protocol Wyn-Dart Wyn-Dart Wyn-Dart

communication interface 2 wire current loop 2 wire current loop 2 wire current loop

fram

e

frame material painted galvanize painted galvanize painted galvanize

stainless steel side frames optional optional optional

dispenser size (unpacked) 70x123x234 cm 70x123x234 cm 70x123x234 cm

dispenser size (packed) 88x143x248 cm 88x143x248 cm 88x143x248 cm

net weight (unpacked) 373.00 kg 373.00 kg 443.00 kg

gross weight (packed) 438.00 kg 478.00 kg 518.00 kg

16

Page 17: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

image model / type product name notes dimensions weight unit

MT100-A MT100 LPG meter

Four piston long life LPG meterAccuracy: %0.25Capacity: 5-10 lt/minInlet/Outlet: 1”Metrological approval from PTB-Germany

23x23x23 cm 19.6 kg PCS

DV-100 Differential Valve3 way differential valveSpring pressure: 3 barDesign pressure: 25 barCast aluminium body

9 . 4 x 8 . 4 x 1 0 . 8 cm 0.8 kg PCS

SP-100 LPG Seperator 19.5x27x42 cm 9.4 kg PCS

SP-200 LPG Seperator 11x13x33.5 cm 4.4 kg PCS

CV-100 Check Valve 4x4x6.2 cm 0.4 kg PCS

RV-100 Safety Relief Valve 3.2x3.2x7.2 cm 0.4 kg PCS

213.53 Pressure Gauge 0-25 bar manometer 6.8x6.8x5.6 cm 0.2 kg PCS

FH-100Cartridge Filter

Housing

8.4x8.4x15 cm 3.2 kg

PCS

FH-101 12x12x19.5 cm 7 kg

CF-100 Cartridge Filter 5.4x5.4x7.5 cm 0.2 kg PCS

SF-100 Seperator Filter 6 . 5 x 6 . 5 x 1 2 . 5 cm 0.4 kg PCS

LH550-PR Trelleborg® LPG Hose 550 cm 4.36 kg PCS

LH500-PR Trelleborg® LPG Hose

LPG hose according to EN1762Type: MID: 19 mmOD: 31 mmFittings: 3/4”

500 cm 4.05 kg PCS

LH400-PR Trelleborg® LPG Hose

LPG hose according to EN1762Type: MID: 19 mmOD: 31 mmFittings: 3/4”

400 cm 3.44 kg PCS

LH050-PR Trelleborg® LPG Hose

LPG hose according to EN1762Type: MID: 19 mmOD: 31 mmFittings: 3/4”

50 cm 1.31 kg PCS

spare partsnon electrical

17

Page 18: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

image model / type product name notes dimensions weight unit

SLVA220-34Solenoid valve

ASCO 3/4” - 220V double bobbin

6x10x16 cm 1.91 kg PCS

SLVA220-10Solenoid valve ASCO 1” - 220V double bobbin

8x16x14 cm 2 kg PCS

SLVA220-15Solenoid valve

ASCO 1.5” - 220V double bobbin

10x17x13 cm 2.75 kg PCS

SLVA220-20Solenoid valve ASCO 2” - 220V double bobbin

12x20x13 cm 4.76 kg PCS

C4MB4 PRO-C4 Mainboard 17.5x4x17 cm 0.745 gr PCS

C4RLY PRO-C4 Relay 10x4x11.5 cm 0.274 gr PCS

C4TL1 PRO-C4 Totalizer-1 Counter

7.5x2x11.5 cm

0.0455 gr PCS

C4TL2 PRO-C4 Totalizer-2 Counter

7.5x2x11.5 cm

0.0575 gr PCS

C4TL3 PRO-C4 Totalizer-3 Counter

7.5x2x11.5 cm 0.068 gr PCS

C4TL4 PRO-C4 Totalizer-4 Counter

7.5x2x11.5 cm 0.079 gr PCS

C4KYB PRO-C4 Keyboard 12x3x18.5 cm 335 gr PCS

C4MLD PRO-C4 Module display 14.5x4x18 cm 0.337 gr PCS

C4CLD PRO-C4 i2c Display 8x8x6 Digit 20x3x23 cm 0.31 gr PCS

C4PSUPRO-C4

Switching mode power supply

14.5x7x16 cm 0.776 gr PCS

S4MB4 S4 PRO-B CPU 19.5x3.5x21.5 cm

1.0645 gr PCS

S4KYB S4 PRO-B Keyboard 12x3x18.5 cm 335 gr PCS

S4TL1 S4 PRO-B Totalizer-1 Counter

7.5x2x11.5 cm

0.0455 gr PCS

spare partselectrical

18

Page 19: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

spare partselectrical

image model / type product name notes dimensions weight unit

S4TL2 S4 PRO-B Totalizer-2 Counter

7.5x2x11.5 cm 0.0575 gr PCS

S4TL3 S4 PRO-B Totalizer-3 Counter 7.5x2x11.5 cm 0.068 gr PCS

S4TL4 S4 PRO-B Totalizer-4 Counter 7.5x2x11.5 cm 0.079 gr PCS

S4PSU S4 PRO-B Power Supply Unit 14.5x5.5x15 cm 0.976 gr PCS

S4C4MBS4 PRO-B / PRO-C4

MEMBRANE KEYPAD

12x17 cm 0.0175 gr PCS

S4DSP S4 PRO-B Display 8x8x6 LCD 20x3x23 cm 0.31 gr PCS

C4DCB PRO-C4 Data Cable 90 cm 0.073 gr PCS

S4DCB S4 PRO-B Data Cable 90 cm 0.073 gr PCS

BTMB2 BETA CPU 20x9x26 cm 1.09 kg PCS

BTKYB BETA Keyboard 10x3x17 cm 0.13 gr PCS

BTINT BETA INTBOX 4.5x5x7 cm 0.0705 gr PCS

BTDCB BETA Cable 50 cm 0.01 gr PCS

BTDSP BETA Display 8x8x6 LCD 20x2x23 cm 0.31 gr PCS

BTMBR BETA Membrane Keypad 10x13 cm 0.015 gr PCS

C4ATCPRO-C4

Temperature Probe for ATC

2.5 mt 0.1515 gr PCS

S4ATCS4 PRO-B

Temperature Probe for ATC

2.5 mt 0.1515 gr PCS

19

Page 20: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

spare partselectrical

image model / type product name notes dimensions weight unit

BTATC BETA Temperature Probe for ATC 2.5 mt 0.1515

gr PCS

L2X16Screen for Keyboards

(C4/S4/BETA)2*16 Dotmatrix LCD 4x1.5x8.5 cm 0.0385

gr PCS

8DLCD 8 Digit LCD 4x1x17.5 cm 0.038 gr PCS

6DLCD 6 Digit LCD 4x1x13.5 cm 0.037 gr PCS

OOSW On/Off Switch 5x7 cm 0.086 gr PCS

PRBTN Preset Button(Green or Red) 3.5x 3x6 cm 0.027 gr PCS

ESBTN Emergency Button 4x3x7 cm 0.04 gr PCS

08-09 Shaft Pulse Encoder

2x50 Pulser 5V DC 9x6.5x13.5 cm 495 gr PCS

EPSE-01 Shaft Pulse Encoder

2x50 Pulser Mechanical Totalizer Output 7x6x15.5 cm 697 gr PCS

EPSE-MM Shaft Pulse Encoder

2x50 Pulser 5V DC 7x6.15.5 cm 697 gr PCS

DSRES Dispenser Heater 3x35 cm 0.143 gr PCS

CPPLC-1LPG Station

Control Panel with PLC

50x70x20 cm PCS

CPCLS-1Simple LPG Station

Control Panel without PLC

50x70x20 cm PCS

ROCLV Level Gauge Transmitter 1 mt 10 gr PCS

GDITK Gas Detector PCS

ESBEXEx-Proof

Emergency Stop Button

PCS

20

Page 21: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

spare partselectrical

image model / type product name notes dimensions weight unit

ALRMS Alarm Siren PCS

C22075L LIYCY Cable 2x2x0.75 MT

C04250N NYY Cable 4x2.5 MT

C02150N NYY Cable 3x1.5 MT

C44000N NYY Cable 4x4 MT

C05150N NYY Cable 5x1.5 MT

INTLOCKInterlock-

Grounding Controller

PCS

AND10LB Anode 10 lb Magnesium PCS

RFECTR CU/CuSO4 Reference PCS

CATPS Cathodic Protection Set

Anode 7 pcs1 pcs Reference ElectrodeAnode JointsCathodic Protection Box

PCS

CATPB Cathodic Protection Box PCS

21

Page 22: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Europump LPG Skid filling stations are specially designed for people who are looking for compact and ready-to-go solutions for dispensing LPG to cars or cylinders.

• Ready to work autogas station solution with steel chassis. Low investment costs.

• Quick return of investment. Minimum workmanship and engineering on site.

• Flexible and modular design.

• Simple layout and maximum safety.

• The plant can be made independent from external power supply (for example in rural areas) with LPG/NG Generator.

• Easy to operate. Comprises all the necessary equipment for safe and reliable filling operation.

main features

22

Page 23: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

LPG Skid System with 5MT above-ground tank and single LPG dispenser with Swiss mass flow meter for cylinder bottle filling.

• 10,000 liters (5MT) or 20,000 liters (10MT) LPG above-ground tank (made according to standard EN13445, Gost material according to EN10028-03) with Rego® valve, rotogauge, Rochester® level indicator, thermometer and manometer, sunshield and bottom steel plate.

• E1-SL/P/MM Eurostar single nozzles dispenser with painted steel frame and one Swiss mass flow meter /one filling head for cylinder bottle filling (one filling head, one module display).

• [RT150-5.5-PS] LPG Pumping Unit Skid (RT150 Turbine Pump + 5.5 kW motor, 2900 rpm+bypass+safety valve+monoblock+manometers on baseplate with coupling) on the stand.

• [CP-PLM] LPG Control panel IP55 (for installation in safety zone only).

• [SE183KG] Gas Detector GPL 290mV (±20mV) corresponding 29mA (±2mA). - total 2 pieces.

skid stationslpg skid system

product code

10,000 l (5mt)

20,000 l (10mt)

23

Page 24: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Our skid LPG stations are modularly designed so they can be customized according to customer needs. It may consist of the following components and features:

capacity m3 3/5/10/22

1200 (3-5 m3)

diameter mm 1600-1700-1900 (10 m3)

1900 (22 m3)

design pressure bar 17.3

test pressure bar 25.8

temperature range °C -20 ~ +70

design code AD CODE 2000

EN 13445, EN 10028-3

technical specifications

lpg storage tank

24

Page 25: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

brand & model ProLPG RT150 EP50-3x

pump type Turbine Side Channel

flow rate 50-130 l/min 50-120 l/min

inlet - outlet 1 1/2” - 1” 2 1/2” - 1 1/4”

working pressure 27.6 bar 27.6 bar

differential pressure 17.2 bar 17.2 bar

casting GG40 GG35

motor 3450 @ 60 Hz / 2880 @ 50 Hz 1450 @ 50 Hz

3.5 kW / 5.5 kW / 7.5 kW, Exproof 3.5 kW / 5.5 kW / 7.5 kW, Exproof

technical specifications

RT150-5.5-PS RT150-5.5-PS-Y

EP50-38-5.5-PS

skid stationslpg pumping units

25

Page 26: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Code Description Quantity

[RT150] Regenerative turbine pump RT150, Europump Italia SRL 1

[5.5-2915] Three phase ATEX motor 5.5 kW 2915 rpm, Cantoni Group 1

[BSP] Baseplate with spark protection 1

[DK38] Coupling for the pump 1

[BBTKV-FS25] BBTKV-FS monoblock carbon steel DN25PN40 1

[BBTKV-FS40] BBTKV-FS monoblock carbon steel DN40PN40 1

[3127G] Safety valve 17.2 bar, Rego® 2

[CV100] Bypass valve CV100 1”, Europump Italia SRL 1

Ball valve DN20PN63 2

Manometer ø63 radial 0-25 bar

CL1.6, stainless steel w/ glycerin 1 or 2 (optional)

Chassis, steel painted 2

lpg pumping unit

product code

RT150-5.5-PSLPG Pump Unit Skid

26

Page 27: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Mini-skid LPG stations are used for small mobile LPG applications. It is a compact mobile LPG station which includes a dispenser, pump, and all other hydraulic systems that should be in a regular LPG station. All you need to do is to connect the inlet and return valve to the tank and connect the system to a power source.

Our skid dispensers can be manufactured with mechanical registers or with electronic register options.

• PTB approved meter.

• Electronic register with ATC / Mechanical register.

• IP65 electronic enclosure.

• RT150 tribune type LPG pump options.

• Exproof ATEX certified motor.

• Bypass valve.

• Flow rate: 5-50 lt/min.

• Electronic presetting as volume and price.

• Electronic system ATC - Automatic Temperature Compensation.

• Automation system communication via Current Loop.

• Different password levels to control register.

• Automatic stop function when vehicle tank is full.

• Easy transport with Euro pallet sizes.

main features

electronic skid system mechanical skid system

skid stationsmini lpg filling stations - skid type

27

Page 28: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

filling unit

unit type Classic Eurostar LPG Dispenser

Eurostar LPG Dispenser with Mass Meter

Mechanical Dispenser Roman Scale Mechanical Clock

Scale Electronic Filling Scale

measurement system PD meter coriolis mass flow meter PD meter mechanical mechanical electronic load cell

filling units liter/gallon liter/kilogram/gallon liter/gallon kilogram kilogram kilogram

volume measurement

mass measurement

density measurement

temperature measurement

temperature compensated

volume

filling nozzles 1 - 4 1 - 4 1 1 1 1

automation software correction

gas leakage sensor

water sprinkler

tank level probe

tank level gauge

skid stationscomponents

28

Page 29: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

The flow computer and indicating device R500 is specially designed by Europump for measuring system EPD500; it is the main component of this installation.In the application of Electronic Register (R500) give opportunity to observe the process of LPG delivery, recording and control of the filling transfer system.

The R500 can be programmed according to the customer’s requirements.

electronic registerr500

product code

R500

29

Page 30: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

EPD500 is an electronic measuring system designed for all the measurement, delivery and reporting needs of LPG terminals, stations or tankers in compliance with the Directive of European Parliament and Council no. 2014/32/EU.

• Atex and Mid certification.

• No moving parts.

• 320x240 Color LCD graphic display (3.2”).

• Measurement principle: Coriolis or PD (optional).

• Measurement range: 0... 750 kg/min.

• Measurement accuracy: ± %0.2 ~ % 0.5.

• Minimum maintenance required.

• Measurement of mass, volume, density and

temperature simultaneously.

• Preset as amount of mass or volume.

• Deadman button.

• Electronic calibration.

• Serial port for printers RS485 - RS232.

• RFID card reader.

• Wifi.

• SD Memory.

• Optional pressure sensor.

• Languages: English, Italian, Russian, Turkish, Serbian

and Spanish.

• Operates at -25°C to 55°C.

• In compliance with the Directive of European

Parliament no. 2014/32/EU.

main features

mass flow meterepd500

product code

EPD-500-1/1/40(with electronic registerless

printer)

30

Page 31: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

flow metersmass flow meters

image code description

8FE15 8FE15‐AD2SAABAA1MN LPG mass 8FE15, DN15‐ Endress+Hauser® mass flow meter DN15

8FE25 8FE25‐AD2SAABAA1MN LPG mass 8FE25, DN25‐ Endress+Hauser® mass flow meter DN25

8FE40 8FE40‐AD2SAABAA1MN LPG mass 8FE40, DN40‐ Endress+Hauser® mass flow meter DN40

EPD-500-1/1/40EPD-500 LPG Truck Meter with Modbus digital communication with DN40 LPG mass flow meter by E+H and vapor separator, differential valve and filter by LC (less printer)

EPD-500-1/0/40 Mastermeter for truck meters (DN40) with mass flow meter (less vapor separator, differential valve, filter and printer)

EPD-500-1/0/15 Mini Counter DN15 mass flow meter

ProLPGMM ProLPG Mass Mastermeter for calibration dispenser with mass flow meter (DN15) by E+H

31

Page 32: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Fluid LPG liquid phase

Number of pistons 4

Nominal unit displacement 0.125 l

Nominal volume per turn 0.5 l

Accuracy ± 0.5%

Minimum flow 5 l/min (l 1/2 gal/min)

Maximum flow 50 l/min (12 gal/min)

Weight 19.6 kg

technical specifications

mt-100a

product code

MT100-A

32

Page 33: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

flow metersmt100b

MT100B is a volumetric type flow meter with pistons. It has been specifically redesigned from its italian origins to measure the flow of LP Gas in the liquid phase, and may also be used for many other liquids. The design and materials used assure good wear and corrosion resistance, accuracy in the measurement at any delivery speed, steadiness of calibration and low maintenance costs.

• High quality Italian Casting.

• Excellent operational safety – reliable under extreme ambient conditions.

• High accuracy of volume measurement even with low flowrates.

• Corrosion resistance with bottom outlet design and stainless steel cylinder liners.

• Four point mechanical calibration.

• Mechanical or Magnetic Coupling options.

main featuresproduct code

MT100-B

33

Page 34: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Rate of flow 75-380 l/min

Working pressure 24 bar

Connections 2" FTP on inlet check valve and differential valve, flanged to meter for easy installation.

Register Veeder-Root, print or non-print

Temperature range -23 ºC to 52 ºC

Temperature compensator Compensates to 15 ºC

technical specifications

• Vapor Eliminator.

• Strainer.

• Differential Valve.

• Optional Trac-bearing Chamber.

• Optional Automatic temperature compensator.

• Internal and external parts are completely compatible with pre-existing, non-Liqua-Tech installations.

main features

Designed for bobtail trucks and bulk plants, the LPM-200 utilizes a durable, all-ductile-iron housing for reliability, durability and years of low-maintenance use.

2" LP-Gas Flow Meter for Trucks

lpm-200

34

Page 35: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

flow meterstcs-700

The 700 series rotary flow meter has no metal-to-metal contact, provides superior accuracy with low pressure drop, low maintenance and a long service life. The 700 series rotary flow meter has a simple and efficient meter design consisting of housing and three rotors that rotate in unison within the measuring chamber. The absence of wear, from no metal-to-metal contact inside the chamber, eliminates any deterioration in accuracy and provides a long service life. The rotors are supported by bearings inserted into two bearing plates, where at the end of each rotor shaft is a timing gear. The timed rotation between each rotor is then transferred through the calibration adjuster to the register, which will then give a consistent and superior measurement of accuracy.

• No metal-to-metal contact within the measuring chamber. - Low Pressure Drop. - Low Maintenance.

• Long Service Life.

• Light and Compact Design.

• Bi-directional Flow Direction.

• Wide Viscosity Range - up to 1,500,00 SSU (325,000 CPS).

• Meets NIST, OIML, ATEX, NMI, S.WA, SABS and many other international weights & measures.

main features

35

Page 36: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

lpg hand pumps

The EPHP is a hand operated LPG pump that can be used to transfer LPG from one tank to another. This pump meets the safety standards for handling highly compressed gases.

image code description

EP-MCS-M Mechanical Clock Scale - Manual bottle filling with mechanical filling head (air compressor not required)

8FE25 Mechanical Clock scale - Pneumatic cylinder bottle filling with pneumatic filling head less air compressor

EP-MCS-S Mechanical Clock scale - standard (without filling head)

EP-CFMPCylinder Filling Mini-Plant semi automatic filling head (RT150 pump /5.5kW Motor Italian Clock Scale pneumatic control (less air compressor)

EFC-8E+FHn6 LPG Electronic Filling Scales (EFC-8E) with Pneumatic Filling Heads (hook type for F-Valves)

product code

EP-HP

36

Page 37: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

cylinder filling

image model / type product features product description unit

ADB-JVM03

• Manual operation• For 12-45 kg cylinders• Valve Type: 20-22 mm• ATEX Certified• Brass construction

ADB Series LPG Cylinder Filling Heads are designed specifically for various types of cylinder valves. They can be produced as manual or automatic pneumatic-operated depending on the needs of the customer. Impermeable material suitable for LPG guarantees many years of service.

PCS

ADB-JVM04• Manual operation• For 12-45 kg cylinders• Valve Type: 27 mm• ATEX Certified

PCS

ADB-FVPUY02

• Pneumatic operation• For 12-45 kg cylinders• Valve Type: 20-22 mm• ATEX Certified• Working air pressure: 6-8

PCS

ADB-FVPU02• Manual operation• For 12-45 kg cylinders• Valve Type: 20-22 mm• ATEX Certified

PCS

ADB-PV01

• Pneumatic operation• For 12-45 kg cylinders• Valve Type: 20-22 mm• ATEX Certified• Working air pressure: 6-8

PCS

ADB-FVPU03

• Pneumatic operation• For 12-45 kg cylinders• Valve Type: 20-22 mm• ATEX Certified• Working air pressure: 6-8

PCS

ADB-JVYO01

• Pneumatic operation• For 12-45 kg cylinders• Valve Type: 27 mm• ATEX Certified• Working air pressure: 6-8• Brass construction

PCS

ADB-KTP03(Picnic Type)

• For 2-6 kg cylinders• ATEX Certified PCS

ADB-KTP02(Picnic Type)

• For 2-6 kg cylinders• ATEX Certified PCS

ADB-JVP02• For 12-45 kg cylinders• Valve type: 17 mm• ATEX Certified

PCS

ADB-3317• Manual operation• For 12-45 kg cylinders• ATEX Certified

PCS

ADB-3318

• Pneumatic operation• For 12-45 kg cylinders• Valve Type: 20-22 mm• ATEX Certified• Working air pressure: 6-8

PCS

equipment

37

Page 38: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Max Working Pressure 25 bar

Static Test (under pressure - not connected) 40 bar

Dynamic Test (under pressure - not connected) 25 bar

Max Flow Rate 40 l/min

Gas Lost After Disconnection 1 cm3

Working Temperatures -40°C / +100°C

technical specifications

PRO LPG 300 A with aluminium sleeve

PRO LPG 300 B with brass sleeve

prolpg 300

image number code description q.ty

1PRO300A Complete Nozzle

Aluminium 1

PRO300B Complete Nozzle Brass

2 ProLPG301 Body 1

3 ProLPG102 Bushing 1

4 ProLPG201 Ball 6

5 ProLPG202 Flexible Ring 1

6 ProLPG703 Inner Frame 2

7 ProLPG203 Ring 1

8 ProLPG304 Junction 1

9 ProLPG204 Ring 1

10 ProLPG305 Lever 1

11 ProLPG306 Fork 1

12 ProLPG307 Spring 2

13 ProLPG308 Push Button 1

14 ProLPG321 Bolt 1

15 ProLPG205 Nut 1

16 ProLPG309 Spring 1

17 ProLPG318 Valve 1

18 ProLPG119 Gasket 1

19 ProLPG320 Ring 1

20 ProLPG312 Head 1

21 ProLPG207 Lip Ring 1

22 ProLPG313 Piston 1

23 ProLPG112 Gasket 1

24ProLPG315 Sleeve (Aluminium) 1

ProLPG325 Sleeve (Brass) 0

25 ProLPG316 Hammer 4

ProLPG317 Complete Fork ProLPG 317 (306+307+308) 1 set

Set of Gaskets (LPG 0203, 0204, 0119, 0320, 0207, 0112) 1 set

22

25 24 23

1

10

11 12 13

15

2 3

4

5

6

8 9

7

14

21 20 19 18 17 16

38

Page 39: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

lpg nozzles

image code description

PRO300A Pro LPG 300A - Aluminium Nozzle (POS 1)

PRO300B Pro LPG 300B - Brass Nozzle (POS 1)

ProLPG711-AGSB 700 Series Nozzle Black Acme H

ZVG2ACME.1 ZVG2 ACME.1 LPG Acme Nozzle 1” with swivel joint 1” female BSP by ELAFLEX

LN-OEM OEM LPG NOZZLE

OT300B OPW OT300B Brass Nozzle by OPW

user-friendly single-action operation and ergonomic design

The entire fueling operation is initiated by simply engaging the nozzle to the receptacle with a single squeeze of the hand. Minimal force required.

maximum durability

Designed specifically for frequent coupling and uncoupling. Heavy-duty brass, aluminium or stainless-steel construction provides excellent corrosion resistance to the harsh fuelling environment.

safety

Will not dispense gas until securely engaged into an appropriate receptacle.Once engaged, will not disengage until released by operator.

39

Page 40: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Max Working Pressure 25 bar

Static Test (under pressure - not connected) 40 bar

Dynamic Test (under pressure - connected) 25 bar

Differential Pressure 71-100 PSI

101-125 PSI

Inlet 1”

Outlet 1”

Weight 3.50 kg

technical specifications

bypass valve

product code

CV100

effective solution for your station

ProLPG bypass valves are designed to protect pumps and hydraulic system components from excessive pressure damage by adjusting the differential pressure of the system. Custom vapor removal system built in. Differential pressure settings are available from 6.5 bar to 8 bar.

maximum durability

Designed specifically for maximum pressure requirements of pumps and LPG stations.

italian quality

Individually leak tested and inspected, traceable with serial numbers.

Bypass valves are designed to protect pumps and hydraulic system components from excessive pressure damage by adjusting the differential pressure of the system.

cv100

40

Page 41: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

lpg pumps

The pump can be thought of as the heart of an LPG Station, therefore it is very important to select a suitable product for your needs. We offer options for both truck and station applications.

brand & model ProLPG RT150 EP50-3x

pump type Turbine Side Channel

flow rate 50-130 l/min 50-120 l/min

inlet - outlet 1 1/2” - 1” 2 1/2” - 1 1/4”

working pressure 27.6 bar 27.6 bar

differential pressure 17.2 bar 17.2 bar

casting GG40 GG35

motor 3450 @ 60 Hz / 2880 @ 50 Hz 1450 @ 50 Hz

3.5 kW / 5.5 kW / 7.5 kW, Exproof 3.5 kW / 5.5 kW / 7.5 kW, Exproof

41

Page 42: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

regenerative turbine pumps

Europump RT-150 is a regenerative turbine pump ideally suited for continuous duty on light liquids. Produces a maximum differential pressure of 10.3 bar and a flow rate up to 132 l/min.

Max Working Pressure 27.6 bar

Max Differential Pressure 17.2 bar

Impeller Bronze O-ring Buna-N

Seal Seat Silicone Carbide

Inlet 1 - 1/2”

Outlet 1”

Motor 3450 rpm @ 60 hz

2880 rpm @ 50 hz

Working Temperatures -35°C / +100°C

technical specifications

rt150

• Excellent for low flows and relatively high head pressures.

• Linear performance curve.

• Floating impeller design: no metal to metal contact.

• Minimal wear: impeller is the only moving part.

• Extremely quiet and free of vibrations.

• Smooth continuous flow.

• Made in Italy

main features

• Autogas dispensing.

• Cylinder filling.

• Vaporizer feed.

• Aerosol propellant.

• Direct burner feed.

• Bulk transfer.

applications

product code

RT150(pump only)

RT150-5.5-2915(pump with 5.5 kW 2915 rpmATEX three phase motor on

baseplate with coupling andspark protection)

42

Page 43: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

pumpsrt150 & spare parts

image model / type description

RT150 Regenerative turbine LPG Pump RT150 (pump only)

RT150-5.5-2915 Regenerative turbine LPG Pump RT150 with ATEX three phase motor 5.5kW, 2915 rpm on the base plate with coupling and spark protection

RT150-5.5-PSLPG Pumping Unit Skid (RT150 Pump + three phase motor 5.5 kW, 2900 rpm + bypass valve + monoblocks + manometer + safety valves + ball

valves on base plate with coupling) on the stand for the filling dispenser

RT150-5.5-PS-Y

LPG Pumping Unit Skid (RT150 Pump + three phase motor 5.5 kW, 2900 rpm + bypass valve + monoblocks +manometer + safety valves + ball

valves on base plate with coupling) on the stand to can fill storage tank and dispenser.

RT150-RKT Repair kit for RT150 pump O-Ring black

RT150-IMP RT150 impeller brass

RT150-SFT RT150 shaft

RT150-MS Mechanical seal for RT150

E041.A005 CARBIDE Carbide shallow for RT150

E041.A005 CARBON Carbon deep for RT150

CV100 Bypass valve 1"

DK38 Coupling for RT150 pump

43

Page 44: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

side channel pumps

The EP50 series pumps are the ideal solution for pumping liquids involving high difference pressure, low NPSH condition and aerated liquids up to 50% gas from underground tanks. Six and Eight side channel models are available by custom order.

Casting GG35

Flow Rate 50 - 120

Max Working Pressure 27.6 bar

Max Differential Pressure 17.2 bar

Inlet 2 - 1/2”

Outlet 1 - 1/4”

Motor 1450 rpm @ 50 hz

3.5 kW / 5.5 kW / 7.5 kW Exproof

technical specifications

ep50 series

product codeEP50-36

(pump only)

EP50-38(pump only)

EP50-36-4-1430(pump with 6 stages EP50-36 with three phase ATEX motor 4 kW, 1430 rpm on the baseplate with coupling and spark protection)

EP50-38-4-1430(pump with 8 stages EP50-38 with three phase ATEX motor 4 kW, 1430 rpm on the baseplate with coupling and spark protection)

44

Page 45: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

pumpsep50 series & spare parts

image model / type description

EP50-36 LPG multi stage side channel pump with 6 stages

EP50-38 LPG multi stage side channel pump with 8 stages

EP50‐36‐4‐1430LPG multi stage side channel pump with 6 stages EP50‐36

with three phase ATEX motor 4 kW, 1430 rpm on the baseplate with coupling and spark protection

EP50‐38‐4‐1430LPG multi stage side channel pump with 8 stages EP50‐38

with three phase ATEX motor 4 kW, 1430 rpm on the baseplate with coupling and spark protection

Impeller 1x impeller for EP50 series pumps

Shaft 6 Stages 1x shaft for EP50-36

Shaft 8 Stages 1x shaft for EP50-38

Mechanical Seal 1x mechanical seal for EP50 series pumps

Carbon Bushing 1x bushing for EP50 series pumps (carbon)

Bronze Bushing 1x bushing for EP50 series pumps (bronze)

Impeller Housing 1x impeller housing

Impeller Cover 1x impeller cover

Suction Impeller 1x suction impeller

Stage Seal 1x 0.8 mm stage seal

Bearing 1x bearing

45

Page 46: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

sliding vane pumps

The Sliding Vane design is ideal for butane, propane, anhydrous ammonia, propellants, refrigerants and similar liquefied gases. It is widely used for cylinder filling, motor fueling, bulk transfer, vaporizers, and on bobtails and transports.

available models

EPV200 with connection size 2", flow rate 220lt/minEPV350 with connection size 3", flow rate 490lt/min

epv series

image model / type description

EPV200 EP‐V200 LPG pump 2'' NPT (pump only)

EPV350 EPV350 LPG pump 3'' NPT (pump only)

EPV200-5.5 Portable LPG transfer pump 2" 200lt/min EPV200 with three phase ATEX motor 5.5 kW, 1450 rpm and V belt

46

Page 47: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

pumpsepv series

№ description q.ty in set q.ty offered № description q.ty in set q.ty offered

1 Case 1 1 19 Bearing 2 1

2 Cam 1 1 20 Cam Key Pin 2 1

3 Head 2 1 21 Grease Seal 2 1

4 Bearing Cap 2 1 22 Mechanical Seal Fitting Pin 2 1

5 Relief Valve Cap 1 1 23 Shaft Key 2 1

6 Shim 1 1 24 Inlet/Outlet Flange 2 1

7 Cam Key 1 1 25 Label 1 1

8 Poppet 1 1 26 Relief Fitting 4 1

9 Relief Valve Spring 1 1 27 Grease Zerk 2 1

10 Sideplate 2 1 28 Lubricap 2 1

11 Vane 6 1 29 O-Ring - Flage

O-Ring - Relief Valve Cap

O-Ring - Case

2 2

12 Vane Driver 3 1 30 1 1

13 Rotor-Shaft Assembly 1 1 31 2 2

14 Mechanical Seal 2 1 32 Relief Valve Cap Bolt 4 1

15 Thrust Bearing 2 1 33 Inlet-Outlet Flange Bolt 4 1

16 Bearing Race Mounting 2 1 34 Head Bolt 8 1

17 Grease Seal 2 1 35 Bearing Head Bolt 4 1

18 Bearing Cap Shim x x 36 Shaft Shield 1 1

47

Page 48: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

pumpslpg pumping units

image description power (kw)

frequency (hz)

speed (rpm)

weight (kg)

Unit with regenerative turbine pump RT150 5.5 50 2915 120

Unit with multistage side channel pump EP50-38 4.0 50 1430 115

Portable LPG transfer pump EPV 200 with three phase

ATEX motor and V-belt drive5.5 50 1450 175

48

Page 49: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Europump supplies a wide range of ATEX motors, both seperately and as part of pump units. The II 2G EExe II series ex-proof motors are three phase asynchronous explosion proof, increased safety and totally enclosed IP 55 motors. They are adapted to operating in hazardous areas excluding mines due to the presence of explosive gases, vapors or mists (Group II).

• Rated outputs for continuous duty.

• Frequency 50 Hz.

• Environment Temperature: -15oC / +40oC.

• Insulation Class F.

• IP55 Certification.

• One free shaft extension according to dimension drawing.

• Terminal Box with glands and 6 x Terminal Board with 6 terminals,

Cable Glands Ex, External Earthing Terminal Ex, Auxiliary Terminal Ex.

• Power: 0.45 - 30 kW.

• HP: 1.0 - 40.0.

• Speed: 750 - 1450 - 2915 rpm.

main features

atex motors

49

Page 50: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

atex motors

image model / type description

4,0-1430-IND Three phase ATEX motor 4.0 kW, 1430 rpm by Cantoni Group (Celma Indukta®)

5.5-2915-IND Three phase ATEX motor 5.5 kW, 2915rpm by Cantoni Group (Celma Indukta®)

5.0-1440-BROOK Three phase ATEX motor 5.0 kW, 1440 rpm by Brook Crompton®

5.5-2900-BROOK Three phase ATEX motor 5.5 kW, 2900 rpm by Brook Crompton®

50

Page 51: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Europump HR101-L is specially designed for the propane delivery industry. Available in galvanized or painted steel options to give you more control in protecting your LPG hoses.

• Avaliable for LPG hoses with diameters 3/4” to 1 1/4”.

• Hydraulic rewind option with gas pump.

• Stainless steel or galvanized body.

• Inlet flange: 1 1/2" with flange.

• Outlet flange: 1 1/4" without flange.

• Gear-driven crank rewind, #40 chain and sprocket drive, hydraulic or

compressed air motor or direct drive hydraulic rewind motor options.

• Design pressure: 25 bar.

• Dimensions: 53x54x60 cm.

main features

hose reelhr101-l

product code

HR101-L(with OEM pneumatic motor)

HR101-L(with USA pneumatic motor)

51

Page 52: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

lpg calibration

Europump LPG Master meters are the fast, reliable and efficient devices for calibration and measurement of commercial LPG Dispensers. Electronic Master meters include ATC (Automatic Temperature Correction). With mass-meter versions it is also possible to measure mass and density in real time.

Europump master meters are rugged, compact, simple to operate and have proven their reputation by weight and measurement authorities of several governments.

master meters

Portable instrument for determining the vapor pressure and the weight of liquified petroleum gas (LPG).

With this kind of equipment it is possible to determine the vapor pressure and weight of the liquid simultaneously with a single reading. Based on the data with the value of pressure measured on the pressure gauge it is possible to determine the percentange of propane and butane in the LPG mix.

thermo densitometer

Hydrometer ASTME100-10Density range 0.500-0.650 kg/m3Scale division: 1 kg/m3Error limit: ± 1 kg/m3Thermometer: 0+35 °C in 0.5 0CFilling: Hg1 error limit: ± 0.5 °C

Hydrometer DIN12804Scale division: 0.0005 g/cm3Error limit: ±0.0005 g/cm3Thermometer: 0+30 °C in 0.5 0CFilling: Hg1 error limit: ± 0.5 °C

• Working pressure 1500 kPa.

• ProLPG hose L= 1 mt.

• Needle valve PN40.

• Stainless pressure gauge Ø63 0-25 bar.

• Transparent resin cylinder for vapor LPG.

main features

product code

COP-TD

52

Page 53: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Europump presents: AutoVerde LPG-Autogas Conversion Systems. AutoVerde has a clear objective to become one of the most premium auto conversion kit brands. AutoVerde consistently designs, supplies, manufactures and delivers some of the worlds highest quality and cost effective conversion kits.

sequential lpg conversion system

carburetor (venturi) lpg conversion system

single point injection lpg conversion system

conversion systems

53

Page 54: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

A good fuel dispenser is key for the success of your petroleum station. Our experience and expertise in petroleum equipment helps us create one of the most reliable and long lasting fuel dispenser series in the market.

• Standalone design (fully self-contained electronics).

• Single, dual, quad, six or eight filling point configurations.

• Long life hydraulic systems.

• Industry standard fuel nozzles with safety breakaways.

• Stainless steel or painted iron cabinet options.

• Europump electronic computers with backlit displays.

• Field programming via alphanumeric keypad.

• Integrated money and volume totalizers.

• Interface availability with Wayne-Dart compatible automation systems.

• International currency options available.

• Automatic Temperature Compensation (ATC).

• Electronic Calibration.

• Pre-set filling as volume or amount.

• Multimedia addons.

main features

54

Page 55: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

fuel dispensers

Nozzle configuration pcs 1 product / 1 nozzle / 1 display 1 product / 2 nozzle / 2 display 2 product / 2 nozzle / 2 display 2 product / 2 nozzle / 4 display

Size cm 45 x 100 x 200 (h)

Number of displays pcs 2-4

Pumping System EE with suction pump DE without pump

Flow Rate l/min 50-70 l/min 120 l/min

technical specifications

eurostar ee & de series

55

Page 56: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

technical specifications

Nozzle configuration pcs 1 product / 1 nozzle / 2 display 1 product / 2 nozzle / 2 display 2 product / 2 nozzle / 2 display 2 product / 2 nozzle / 4 display 3 product / 6 nozzle / 2 display 4 product / 8 nozzle / 2 display 4 product / 8 nozzle / 4 display

Size cm 45 x 123 x 230 (h) 45 x 95 x 230 (h)

Number of displays pcs 2-4

Pumping System EE with suction pump DE without pump

Flow Rate l/min 50-70 l/min 120 l/min

eurostar et & dt series

56

Page 57: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

fuel dispensers

Nozzle configuration pcs 1 product / 1 nozzle / 2 display 1 product / 2 nozzle / 2 display 2 product / 2 nozzle / 2 display 2 product / 2 nozzle / 4 display 3 product / 6 nozzle / 2 display 4 product / 8 nozzle / 2 display

Number of displays pcs 2

Pumping System EE with suction pump DE without pump

Flow Rate l/min 50-70 l/min 120 l/min

technical specifications

eurostar eo & do series

57

Page 58: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

fuel dispensers

eurostar ee xx-m3 and de xx-m3 series

image model / type hydraulic system

capacity (l/min)

fuel type nozzle display dispenser size

(unpacked)dispenser size

(packed)

EUROSTAR EE11-M3 Suction 45/70 1 1 2

48x104x185 cm

63x128x197 cm

EUROSTAR DE11-M3 Dispenser 45/70 1 1 2

EUROSTAR EE12-M3 Suction 45/70 1 2 2

EUROSTAR DE12-M3 Dispenser 45/70 1 2 2

EUROSTAR EE22-M3 Suction 45/70 2 2 4

EUROSTAR DE22-M3 Dispenser 45/70 2 2 4

eurostar et xx-mp and dt xx-mp series

image model / type hydraulic system

capacity (l/min)

fuel type nozzle display dispenser size

(unpacked)dispenser size

(packed)

EUROSTAR ET22-MP Suction 45/70 2 2 2

70x96x235 cm 75x110x247 cm

EUROSTAR DT22-MP Dispenser 45/70 2 2 2

EUROSTAR ET24-MP Suction 45/70 2 4 2

EUROSTAR DT24-MP Dispenser 45/70 2 4 2

EUROSTAR ET24-MP/4 Suction 45/70 2 4 4

EUROSTAR DT24-MP/4 Dispenser 45/70 2 4 4

EUROSTAR ET36-MP Suction 45/70 3 6 2

70x126x235 cm

75x140x247 cm

EUROSTAR DT36-MP Dispenser 45/70 3 6 2

EUROSTAR ET48-MP Suction 45/70 4 8 2

EUROSTAR DT48-MP Dispenser 45/70 4 8 2

EUROSTAR ET48-MP/4 Suction 45/70 4 8 4

EUROSTAR DT48-MP/4 Dispenser 45/70 4 8 4

58

Page 59: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

• Tank with capacity of 20 m3 or 45 m3.

• Included fuel dispenser available with single or dual nozzle options.

• Container size: 20 ft (2438x2590x6058 mm) or 40 ft.

• (2438x2590x12235 mm).

• Container door with standard mechanism lock.

• Fire extinguisher with capacity of 12 kg featuring pressure gauge dry chemical powder with ABC powder.

• Ex-proof lighting system (Ex-proof on-off switch and emergency stop switch, etc.) and electrical control panel.

• 2KWA regulator to protect the fuel pump against

voltage dips or spikes.

• Upper level float switch system to prevent overflow.

• Check valve that make it easier to suction in fuel pump and lower suction installation.

• Galvanized tanker-tank and tank-tanker pipes, ventilation and pump suction.

• Mechanical float transmitter and level gauge with electronic panel.

• Included tanker filling instructions and warning signs (no smoking, turn off mobile phone, etc.).

main features

mobile fuel stations

59

Page 60: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Calibration is the process of finding a relationship between two unknown quantities (when the measurable quantities are not given a particular value for the considered amount, or a standard for the quantity is not found). When one quantity is known, which is made or set with one device, another measurement is made in as similar a way as possible with the first device using the second. Europump is one of the oldest manufacturers and vendors of calibration devices for fuel and LPG.

The ZX-101XL can tell you if you are reading Gasoline or Ethanol Blended Fuels, helping you quickly measure any kind of fuel where and when you need it most.

Portable Octane and Cetane Analyzer

fuel calibration

60

Page 61: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

The main principle of the automation system is to connect and control all the fuel equipment in the station to interface units that are connected to the controller computer. Main software can control dispensers, trailers or bobtails, storage tanks, sensors, cameras etc.

Our extensive experience in the automation systems market makes us a first choice in petroleum automation applications.

• Pump automation.

• Tank automation.

• Customer and Vehicle Identification System.

• Station market and Accounting software.

• DVR and Camera system.

• Tanker Delivery Integration.

• PDA and Web Reporting tools.

station automation

• Liquid fuel tanker truck automation.

• LPG tanker truck automation.

• Tanker track over satellite.

• DVR Modules.

tanker truck automation

automation solutionsstation & truck automation

61

Page 62: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

automation 4.0 is a revolution.

We connect your dispensers, delivery/consumption meters, tank gauging probes, consoles, scales and everything else located in your station.

automation 4.0 is much more cost efficient than traditional automation solutions.

You can monitor your station from any smartphone, tablet or computer.

automation 4.0

62

Page 63: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

control panels

automation solutions

Europump Station Control Panel is specially designed for the monitoring and safety needs of your station. It comes in both exproof or non-exproof versions with the following specifications:

• Tank level monitoring.

• Alarms for low and high levels of tank liquid.

• Gas Sensor alarms.

• Pump and dispenser phase controls.

• Emergency stop button.

• Three phase electricity control.

• Level control for up to 2 tanks.

• Control up to 4 pcs gas sensor.

• 1 pcs x Gas alarm output.

• Control LPG pumps and dispensers based on tank levels.

• Set alarm levels for low and high tank levels.

• 16x2 LCD Information screen.

• Realtime clock.

• Plastic IP55 or ATEX certified Exproof enclosure.

• Optional RS232 Communication output.

CP-PLC-1-IP55 CP-PLC-2-IP55 CP-EX(Exproof)

product code

CP-PLC-1

CP-EX(Exproof)

63

Page 64: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

The trademarks and logos used on this page are protected by commercial rights and are registered trademarks of Alisonic srl®. Europump International® is not affiliated with any of them.

Page 65: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

• Wet stock management up to 35 tanks.

• Graphical display with resistive touch screen TFT 7”.

• Easy and smart configuration tool through local graphical

interface or web.

• Communication protocols used by the more common station

management systems (Gilbarco, Doms, Dresser Wayne,

Tokheim, etc.).

• Automatic reconciliation.

• Dynamic and statical leakage.

• Tank auto-calibration.

• Deliveries, trends, events, alarms recording.

• PLLD (Pressure Level Leak Detection).

main features

• Manages up to 4 tanks.

• Colour 3,5” TFT touch screen graphical display.

• Tank strapping table (100 linearization points).

• The display shows: - Product level/mm. - Interface level/mm (water pesence detection). - Real and compensate volume at 15 °C in liters. - Product mean temperature 5 temp. sensors. - Volume of empty part in liters (ullage).

main features

sibylla

helios tft

tank gauging systemsconsoles

65

Page 66: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

level gauges

delphi exd/ss wired magnetostrictive level gauge

• Wet stock management up to 35 tanks.

• Graphical display with resistive touch screen TFT 7”.

• Easy and smart configuration tool through local graphical

interface or web.

• Communication protocols used by the more common station

management systems (Gilbarco, Doms, Dresser Wayne,

Tokheim, etc.).

• Automatic reconciliation.

• Dynamic and statical leakage.

• Tank auto-calibration.

• Deliveries, trends, events, alarms recording.

• PLLD (Pressure Level Leak Detection).

main features

delphi rs wired magnetostrictive level gauge

• Stainless steel enclosure AISI 304, external diameter Ø 42 mm.

• Tank connection: in riser, threaded or flanged.

• S.S. pipe AISI 304/316 Ø 14/18 mm.

• N. 2 inox AISI 316/NBR floats Ø 42/52 mm.

main features

66

Page 67: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

tank gauging systemslevel gauges

delphi rtd wireless magnetostrictive level gauge

• Stainless steel AISI 305 and Delrin enclosure, external diameter Ø 42 mm.

• IP 68 protection up to 10 m/24h water submersion.

• Tank connection: in riser, threaded or flanged.

• Stainless steel pipe AISI 304 / 316 Ø 14.0 mm.

• N. 2 INOX AISI 316 / NBR floats Ø 42 / 52 mm.

• Intrinsically safe construction for installation in classified 0 zone.

• Integrated battery and antenna.

• Power supply: intrinsically safe lithium battery.

• Product level / mm.

• Interface level / mm (water presence detection).

• Product average temperature max 5 sensors.

• Measuring probe accuracy: ± 0,5 mm.

• Real probe resolution: ± 0,05 mm.

• Temperature accuracy -20 ÷ +50 °C: ± 0,2 °C.

main features

67

Page 68: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

level gauges

• Measuring range up to 15 m.

• Stainless steel AISI 303 and Delrin enclosure Ø 42 mm.

• IP 68 degree protection up to 10 m. water submersion max. 24h.

• Tank connection: threaded or flanged.

• Corrugated stainless steel pipe AISI 316 Ø 18.0 mm.

• N. 2 INOX AISI 316 / NBR floats Ø 105 / 50 mm.

• Intrinsically safe construction 0 zone classified.

• Wired RS485 and wireless versions.

• Electrical features as above (see Delphi RS and Delphi RTD.

• Product level / mm.

• Interface level / mm (water presence detection).

• Product average temperature max 5 sensors.

• Measuring probe accuracy: ± 1.0 mm.

• Real probe resolution: ± 0.05 mm.

• Repeatability ± 0.2 mm.

• Temperature accuracy -20 ÷ +50 °C: ± 0.2 °C.

main features

delphi 485fx \ delphi rtd-fxflexible magnetostrictive probe - wired and wireless executions

68

Page 69: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

cyclops mechanical dial level indicator

• Suitable for underground and above ground tank.

• Measurements up to 20 m.

• Remote communication.

• Accuracy ± 5 mm.

• ATEX compliance.

main features

helios prn mechanical dial level indicator

• Wall mounting printer.

• Polycarbonate IP41 enclosure.

• Enclosure dimensions 151 x 125 x 60 mm.

• 200 dpi high quality speed.

• Width paper 58 mm.

• Paper 55-70 g/mq, Ø 50 mm.

• Power supply 220Vac.

• 4Mb flash internal memory logos and fonts.

• RS232 interface.

• International fonts available.

• Sensors: temperature head, paper presence.

• UL, CE, FCC compliance.

• Temperature extended -20 +70 °C.

main features

tank gauging systemsdial level indicators

69

Page 70: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

The trademarks and logos used on this page are protected by commercial rights and are registered trademarks of Corken®. Europump International® is not affiliated with any of them.

Page 71: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Europump offers oil-free gas compressors that deliver high efficiency in handling propane, butane, anhydrous ammonia and other liquified gases. They are ideal for rail car unloading and vapor recovery applications. All parts are designed to give maximum performance and reliability under the most severe service conditions. All pressure parts are of ductile iron construction for greater resistance to both thermal and mechanical shock. They are designed for ease of maintenance, with all components readily accessible.

Models are available with capacities ranging from 7 to 125 cfm (11.9 to 212 m3/h) with working pressures up to 425 psi (29.31 bar).

Max Working Pressure 24 bar

Max Transfer Capacity 57.5 m3/h

Motor Power (up to) 11 kW

Working Temperature -20 oC / +60 oC

Transfer Capacity 770 l/min

technical specifications

compressors

71

Page 72: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Complete compressor unit, type ZK291 (Corken® configuration 291-107A-7,5 kW)

The unit is designed for handling vapors of propane, butane and any mixtures of these gases.

technical specifications

• Bore of cylinder: 3.0”

• Stroke: 2.5”

• Minimum piston displacement: 13.6 m3/h @400 rpm

• Maximum piston displacement: 28.0 m3/h @825 rpm

• Maximum working pressure: 24.1 bar

• Maximum brake kW: 11.0 kW

• Maximum outlet temperature: 177 °C

• Maximum nominal rate of flow: 22.9 m3/h (for propane)

72

Page 73: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

compressorsZK291

quantity unit part description

1 PCS Corken® compressor type 291AM3FBANSNN compressor unit will be additionally painted.

2 PCS liquid filled pressure gauges one fitted at suction side, second at discharge side of the compressor.

1 PCS zinc plated steel base-plate

1 PCSCE marked (according to PED) automatic liquid trap

equipped with Endress+Hauser® level switch in explosion proof execution (class: Ex de IIC T3...T6)

provides signal to shut off the electric motor of the compressor unit in case of excessive level of liquid accumulated in the liquid trap. Manual drain of liquid trap through the drain valve.

1 PCS 1” NPT 4-way ball valve

1 SET interconnecting piping

1 PCS 1” NPT strainer

1 PCS hydrostatic relief valve

1 PCS zinc-plated adjustable drivel slide base

1 SET V-belt drive includes V belts in antistatic execution as well as compressor and electric motor wheels.

1 PCS V-belt drive guard

1 PCS 7.5 kW electric motor in Ex execution(Ex e or Ex de)

compressor parts

Flexible steel hose (compensator) DN25, L=500 mm, end connections: 1" MNPTxDN25, PN40 fixed flange

(2 pcs. of flexible compensators are needed for connecting 1 compressor unit. Flexible compensators prevent transmission of vibrations from the compressor unit onto piping and protects 4-way valve from excessive forces).

product code

ZK291with Ex e motor

ZK291with Ex de motor

73

Page 74: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Complete compressor unit, type ZK491 (Corken® configuration 491-107A-11 kW)

The unit is designed for handling vapors of propane, butane and any mixtures of these gases.

Flexible steel hose (compensator) DN40, L=500 mm, end connections: 11/2” MNPTxDN40, PN40 fixed flange

(2 pcs. of flexible compensators are needed for connecting 1 compressor unit. Flexible compensators prevent transmission of vibrations from the compressor unit onto piping and protects 4-way valve from excessive forces).

technical specifications

• Bore of cylinder: 4.0”

• Stroke: 3.0”

• Minimum piston displacement: 29.2 m3/h @400 rpm

• Maximum piston displacement: 60.3 m3/h @825 rpm

• Maximum working pressure: 24.1 bar

• Maximum brake kW: 11.0 kW

• Maximum outlet temperature: 177 °C

• Maximum nominal rate of flow: 48.80 m3/h (for propane)

74

Page 75: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

compressorsZK491

quantity unit part description

1 PCS Corken® compressor type 491AM3FBANSNNwith flywheel (740 rpm on the compressor shaft as standard)

compressor unit will be additionally painted.

2 PCS liquid filled pressure gauges

one fitted at suction side, second at discharge side of the compressor.

diameter of dial 63 mm, measuring range 0–25 bar, process connection 1/4” MNPT.

1 PCS zinc plated steel base-plate

1 PCS

CE marked (according to PED) automatic liquid trap equipped with Endress+Hauser® level switch in explosion proof execution (class: Ex de IIC T3...

T6)

provides signal to shut off the electric motor of the compressor unit in case of excessive level of liquid accumulated in the liquid trap. Manual drain of liquid trap through the drain valve.

1 PCS 11/2” NPT 4-way ball valve

1 SET interconnecting piping

1 PCS Y-type strainer 11/2” FNPT

1 PCS safety relief valve

1 PCS zinc-plated adjustable drivel slide base

1 SET V-belt drive includes V belts in antistatic execution as well as compressor and electric motor wheels.

1 PCS V-belt drive guard

1 PCS 11.0 kW electric motor in Ex execution(Ex e or Ex de)

compressor parts

Flexible steel hose (compensator) DN25, L=500 mm, end connections: 1" MNPTxDN25, PN40 fixed flange

(2 pcs. of flexible compensators are needed for connecting 1 compressor unit. Flexible compensators prevent transmission of vibrations from the compressor unit onto piping and protects 4-way valve from excessive forces).

product code

ZK491with Ex e motor

ZK491with Ex de motor

75

Page 76: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Complete compressor unit, type ZK691 (Corken® configuration 691-107A-22.0 kW)

The unit is designed for handling vapors of propane, butane and any mixtures of these gases.

technical specifications

• Bore of cylinder: 4.5”

• Stroke: 4.0”

• Minimum piston displacement: 49.6 m3/h @400 rpm

• Maximum piston displacement: 102.3 m3/h @825 rpm

• Maximum working pressure: 24.1 bar

• Maximum brake kW: 26.1 kW

• Maximum outlet temperature: 177 °C

• Maximum nominal rate of flow: 82.0 m3/h (for propane)

76

Page 77: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

compressorsZK691

Flexible steel hose (compensator) DN40, L=500 mm, end connections: 11/2” MNPTxDN40, PN40 fixed flange

(2 pcs. of flexible compensators are needed for connecting 1 compressor unit. Flexible compensators prevent transmission of vibrations from the compressor unit onto piping and protects 4-way valve from excessive forces).

quantity unit part description

1 PCS Corken® compressor type 691AM3FBANSNN

with flywheel, oil pressure gauge and external oil filter (rpm on the compressor shaft is 760).

compressor unit will be additionally painted.

2 PCS liquid filled pressure gaugesone fitted at suction side, second at discharge side of the compressor.

diameter of dial 63 mm, measuring range 0–25 bar, process connection 1/4” MNPT.

1 PCS zinc plated adjustable drivel slide base

1 SET V-belt drive includes V-belts in antistatic execution as well as electric motor wheel.

1 PCS automatic liquid trap equipped with 1 pcs Endress+Hauser® vibration level switch

generates signal for shut off of electric motor in case of excessive level of liquid accumulated in the liquid trap. Manual drain of liquid from liquid trap.

ATEX approved - Ex de IIC T3...T6 and CE marked.

1 PCS Y-type strainer 11/2” FNPT stainless steel construction.

1 PCS 11/2” FNPT 4-way ball valve stainless steel body and ball, PTFE ball seals.

1 SET interconnecting piping

1 PCS 1/2” safety relief valve fitted on the discharge side of the compressor.

1 PCS zinc plated main steel base-plate

1 PCS V-belt drive guard

1 PCS 22.0 kW electric motor in Ex execution(Ex e or Ex de)

compressor parts

product code

ZK691with Ex e motor

ZK691with Ex de motor

77

Page 78: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Complete compressor unit, type ZK891 (Corken® configuration 891-107B-30 kW)

The unit is designed for handling vapors of propane, butane and any mixtures of these gases.

technical specifications

• Bore of cylinder: 4.5”

• Stroke: 4.0”

• Minimum piston displacement: 96.2 m3/h @400 rpm

• Maximum piston displacement: 192.0 m3/h @825 rpm

• Maximum working pressure: 32.1 bar

• Maximum brake kW: 34 kW

• Maximum outlet temperature: 177 °C

• Maximum nominal rate of flow: 157.6 m3/h (for propane)

78

Page 79: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

compressorsZK891

Flexible steel hose (compensator) DN50, L=500 mm with one fixed DN50 flange and 1 rotating DN50 flange

(2 pcs. of flexible compensators are needed for connecting 1 compressor unit. Flexible compensators prevent transmission of vibrations from the compressor unit onto piping and protects 4-way valve from excessive forces).

quantity unit part description

1 PCS Corken® compressor type FD891JM4PFBANSNNwith flywheel (rpm on the compressor shaft is 760).

compressor unit will be additionally painted.

2 PCS liquid filled pressure gaugesone fitted at suction side, second at discharge side of the compressor.

diameter of dial 63 mm, measuring range 0–25 bar, process connection 1/4” MNPT.

1 PCS oil pressure gauge fitted at crankcase of compressor, body made of steel, measuring range 0–3 bar, connection 1/8” MNPT, diameter of dial 55 mm.

1 PCS 30 kW electric motor in Ex execution according to ATEX class of the motor is: Ex de IIC T5; 400 V/690 V (delta/star); 50 Hz; 1472 rpm.

1 PCS zinc-plated adjustable drivel slide base

1 SET V-belt drive includes V-belts in antistatic execution as well as electric motor wheels.

1 PCSCE marked (according to PED) automatic liquid trap equipped with two Endress+Hauser® level

switches in Ex execution

generate signals that can be used for alarm activation and shutting off the electric motor of the compressor in case of excessive level of liquid accumulated in the liquid trap. Manual drain of liquid trap through the drain valve.

1 PCS Y-type strainer 2’’ FNPT

1 PCS DN50 flanged 4-way ball valve stainless steel

1 SET interconnecting piping

1 PCS safety relief valve fitted on the discharge side of the compressor

1 PCS zinc plated main steel base-plate

1 PCS V-belt drive guard

compressor parts

product code

ZK891with Ex e motor

ZK891with Ex de motor

79

Page 80: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

The trademarks and logos used on this page are protected by commercial rights and are registered trademarks of Batusan®. Europump International® is not affiliated with any of them.

Page 81: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

ss-304 stainless steel / wafer / full bore / hand-lever operated

technical specificationsConnections : EN 1092

Pressure Level : PN40

Temperature : -30 ºC / +250 ºC

Applications : natural gas, LPG-LNG, fuel-oil,

pressurized air and other gases etc.

Connections : EN 1092

Pressure Level : PN40

Temperature : -30 ºC / +250 ºC

Applications : natural gas, LPG-LNG, fuel-oil,

pressurized air and other gases etc.

technical specifications

carbon steel / wafer / full bore / hand-lever operated

monoblock ball valvesbbtkv-fs

81

Page 82: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Dimensions : TS 9809 / EN 558

Connections : EN 1092 - 1/2

Pressure Level : PN40

Temperature : -30 ºC / +180 ºC

Applications : natural gas, LPG-LNG, fuel-oil,

pressurized air and other gases etc.

technical specifications

bdkv-fl-tg

carbon steel / flanged / full bore / hand-lever operated

Dimensions : TS 9809 / EN 558

Connections : EN 1092 - 1 / 2

Pressure Level : 25

Temperature : -30 ºC / +180 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

ductile iron / flanged / full bore / hand-lever operated

82

Page 83: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

carbon steel / threaded / full bore / hand-lever operated

natural gas ball valvesbdkv-di-tg

Dimensions : TS EN 331

Connections : EN 10226-1

Pressure Level : PN40

Temperature : -30 ºC / +180 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

carbon steel / threaded / full bore / hand-lever operated

Dimensions : TS EN 331

Connections : EN 10226-1

Pressure Level : PN25

Temperature : -30 ºC / +180 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

83

Page 84: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

carbon steel / flanged / full bore / hand-lever operated

Dimensions : EN 558

Connections : EN 1092-1

Pressure Level : PN40

Temperature : -30 ºC / +180 ºC

Applications : cold/hot water, steam, pressurized air

technical specifications

natural gas ball valvesbkv-fl-tg

84

Page 85: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Connections : EN 10226-1

Pressure Level : PN40

Temperature : +180 ºC

Applications : asphalt, goods and chemicals industries

technical specifications

carbon steel / threaded / full bore / hand-lever operated

bkv-cek-di-tg

Dimensions : EN 558

Connections : EN 1092-1

Pressure Level : PN40

Temperature : +180 ºC

Applications : asphalt, goods and chemicals industries

technical specifications

carbon steel / flanged / full bore / hand-lever operated

jacketed ball valvesbkv-cek-fl-tg

85

Page 86: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Connections : EN 10226-1

Pressure Level : PN40

Temperature : -30 ºC / +180 ºC

Applications : hot/cold water, steam, pressurized air

technical specifications

carbon steel / threaded / full bore / hand-lever operated

bkv-di-tg

Connections : EN 10226-1

Pressure Level : PN25

Temperature : -20 ºC / +180 ºC

Applications : hot/cold water, steam, pressurized air

technical specifications

ductile iron / threaded / full bore / hand-lever operated

86

Page 87: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

ductile iron / flanged / full bore / hand-lever operated

Dimensions : TS 3148 / EN 558

Connections : EN 1092-1

Pressure Level : PN25

Temperature : -20 ºC / +180 ºC

Applications : cold/hot water, steam, pressurized air

technical specifications

ball valvesbkv-fl-tg

87

Page 88: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

ball valves ansi class 150bkv-fl-tg

floating / carbon steel / flanged / full bore / hand-lever operated

Design : API 6D / ISO 14313

Dimensions : ASME B 16.10

Connections : ASME B 16.5

Pressure Level : CLASS 150 (PN20)

Temperature : -29 ºC / +180 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

trunnion / carbon steel / flanged / full bore / hand-lever operated

Design : API 6D / ISO 14313

Dimensions : ASME B 16.10

Connections : ASME B 16.5

Pressure Level : CLASS 150 (PN20)

Temperature : -29 ºC / +180 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

88

Page 89: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

trunnion / carbon steel / flanged / full bore / hand-lever operated

Design : API 6D / ISO 14313

Dimensions : ASME B 16.10

Connections : ASME B 16.5

Pressure Level : CLASS 300 (PN50)

Temperature : -29 ºC / +180 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

floating / carbon steel / flanged / full bore / hand-lever operated

Design : API 6D / ISO 14313

Dimensions : ASME B 16.10

Connections : ASME B 16.5

Pressure Level : CLASS 300 (PN50)

Temperature : -29 ºC / +180 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

ball valves ansi class 300bkv-fl-tg

89

Page 90: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

trunnion / carbon steel / flanged / full bore / hand-lever operated

ball valves ansi class 600bkv-fl-tg

Design : API 6D / ISO 14313

Dimensions : ASME B 16.10

Connections : ASME B 16.5

Pressure Level : CLASS 600 (PN100)

Temperature : -29 ºC / +180 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

90

Page 91: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

floating / carbon steel / threaded / full bore / hand-lever operated

Design : API 6D / ISO 14313

Dimensions : ASME B 16.10

Connections : ASME B 1.20.1

Pressure Level : CLASS 800 Lbs (PN55)

Temperature : -29 ºC / +180 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

ball valves class 800 lbsbkv-di-tg

91

Page 92: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Connections : EN 10226-1

Pressure Level : PN16 / PN40

Temperature : -30 ºC / +180 ºC

Applications : hot/cold water, steam, pressurized air

technical specifications

carbon steel / threaded / full bore / hand-lever operated

bkv-3y-l-di-tg

92

Page 93: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

carbon steel / flanged / full bore / hand-lever operated

ball valves 3 ways L typebkv-3y-l-fl-tg

Dimensions : EN 558

Connections : EN 1092 - 1

Pressure Level : PN16 / PN40

Temperature : -20 ºC / +180 ºC

Applications : hot/cold water, steam, pressurized air

technical specifications

93

Page 94: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

carbon steel / threaded / full bore / hand-lever operated

Connections : EN 10226-1

Pressure Level : PN16 / PN40

Temperature : -30 ºC / +180 ºC

Applications : hot/cold water, steam, pressurized air

technical specifications

bkv-3y-t-di-tg

94

Page 95: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

carbon steel / flanged / full bore / hand-lever operated

Dimensions : EN 558

Connections : EN 1092 - 1

Pressure Level : PN16 / PN40

Temperature : -30 ºC / +180 ºC

Applications : hot/cold water, steam, pressurized air

technical specifications

ball valves 3 ways T typebkv-3y-t-fl-tg

95

Page 96: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

carbon steel / threaded

Connections : EN 10226-1

Pressure Level : PN40

Temperature : -30 ºC / +180 ºC

Applications : hot/cold water, steam, pressurized air

technical specifications

carbon steel / flanged

Dimensions : EN 558

Connections : EN 1092 - 1

Pressure Level : PN40

Temperature : -30 ºC / +180 ºC

Applications : hot/cold water, steam, pressurized air

technical specifications

check valvesbcv-fl

bcv-di

96

Page 97: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

ductile iron / flanged

Dimensions : TS 11494 / EN 558

Connections : EN 1092 - 1/2

Pressure Level : PN25

Temperature : -40 ºC / +400 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

steel casting / flanged

strainersbpt-fl

Dimensions : TS 11494 / EN 558

Connections : EN 1092 - 1/2

Pressure Level : PN40

Temperature : -40 ºC / +400 ºC

Applications : LPG-LNG, natural gas, fuel-oil,

pressurized air and other gases etc.

technical specifications

97

Page 98: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

bag-fl

cast iron / flanged

Dimensions : EN 558

Connections : EN 1092 - 1/2

Pressure Level : PN16

Temperature : -10 ºC / +180 ºC

Applications : water, foodstuffs, chemistry, air and

other gases etc.

technical specifications

carbon steel / flanged

Dimensions : EN 558

Connections : EN 1092 - 1/2

Pressure Level : PN40

Temperature : -10 ºC / +180 ºC

Applications : water, foodstuffs, chemistry, air and

other gases etc.

technical specifications

98

Page 99: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

cast iron / threaded

sight glassesbag-di

Connections : EN 10226-1

Pressure Level : PN16

Temperature : -10 ºC / +180 ºC

Applications : water, foodstuffs, chemistry, air and

other gases etc.

technical specifications

carbon steel / threaded

Connections : EN 10226-1

Pressure Level : PN40

Temperature : -10 ºC / +180 ºC

Applications : water, foodstuffs, chemistry, air and

other gases etc.

technical specifications

99

Page 100: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

The trademarks and logos used on this page are protected by commercial rights and are registered trademarks of MannTek®. Europump International® is not affiliated with any of them.

Page 101: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

couplings

image code description

L231B4471L231B4471 LPG TANK UNIT SS/VI LT 2"LPG Tank Unit in INOX 316 for LPG, Socket 71mm, flange DN 50 UNI PN 25/40, Seals: Viton LT, PS 25 bar

C200D1300C200D1300 RUBBER CAP FOR LPG T.U. 71mmRubber cap for quick connectionMale socket 71 mm

L124A4471

L124A4471 LPG TANK UNIT SS/VI LT 1"-DN25 PN 25/40 LPG Tank unit 1 " (56 mm) in INOX 316with flanged connection DN 25 PN 25/40.Seals in FKM-LT (Viton LT).PS 25 bar.

C100D1300C100D1300 RUBBER CAP FOR LPG T.U. 1"Rubber cap for quick connectionMale socket 56 mm

M210A4471A

M210A4471A LPG HOSE UNIT 2" BSP SS/VI LT SOCKET 71mm LPG Hose Unit INOX / VI LT2 " socket 71 mmwith female thread 2 " BSPPS 25 bar

V200A2201 V200A2201 CAP FOR LPG HOSE UNIT, SOCKET 71 MMPlastic cap 2 " (71 mm) for LPG Hose unit 2 " (71 mm)

M103A4471A

M103A4471A LPG HOSE UNIT 1"-1" BSP SS/VI- LTLPG Hose Unit in 316 INOX for LPG56mm socket, 1 "BSP connectionSeals: Viton LTPS 25 bar

V100A2201 V100A2201 CAP 1" FOR LPG HOSE UNITPlastic cap 1"

101

Page 102: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

The trademarks and logos used on this page are protected by commercial rights and are registered trademarks of Rochester Gauges Inc®. Europump International® is not affiliated with any of them.

Page 103: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

H

ID

OD

WHAT NEEDS TO BE KNOWN TO SIZE A ROCHESTER GAUGE : _____________________________________________________________

Absolutely needed to define STEM and FLOAT lengths.

OD : External diameter

ID : Internal diameter

H : Riser size

ANGLE TOP

SIDE END

Liquid to be gauged, with its density if specific.

Working pressure and temperature, if unusual.

Mounting position (see drawing).

-Shape of dished end for end mounting gauge-Tank drawing required for angle mounted gauge

Options : -Screws (UNF / Metric / none), Gasket (Buna-n / Teflon / none), Cover.-62** serie : dial size (40-50-100 mm diameter).-63** serie : Application: Mobile (63**M)or Stationary (63**S) tank,

dial size (100-200 mm diameter), TRIM n°, which specify the material according to the application, Mounting studs (centerline or straddle mounted).

If the tank to be gauged is not cylindrical and horizontal, always join a drawing with all the tank

dimensions and the position of the gauge.

For vertical tank, also specify the portion of the tank to be gauged and the total content.

STEM

FLOAT

level gauges6300 series

103

Page 104: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

The 6300 Series Magnetel® liquid-level gauges are designed to accurately determine the percentage of total tank volume for most liquids in stationary-storage applications. UL listed for LP Gas and NH3 service.

The large, easy-to-read dials are also easy to remove and replace. Materials of construction vary depending on the types of liquids to be gauged. Many different optional features are available to meet your specific needs. These materials and options, along with their pricing impact, are summarized for each model in the price list.

Magnetel® gauges are designed for working pressures ranging from atmospheric to 31 bar.

These Magnetel® Gauges are available in four basic models:

• Model 6336 - Incorporates 4" (100 mm) dial and is designed for top mounting.

• Model 6360 - Incorporates 8" (200 mm) dial and is designed for top mounting.

• Model 6339 - Incorporates 4" (100 mm) dial and is designed for side, end or angle mounting.

• Model 6342 - Incorporates 8" (200 mm) dial and is designed for side, end or angle mounting.

main features

6300 series

104

Page 105: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

This series of 1” NPTF Junior™ gauges is available with

Forged brass head.

Gauging LP Gas levels in ASME tanks and DOT Cylinders.

main features

application

1” magnetic liquid-level gauges for lp gas service

model / type

head material mounting dial type

B8981 Brass Top JR 40 mm

8981 Zinc Top JR 40 mm

level gauges8900 series

technical specifications

Temperature Range -40 ºC / +70 ºC

Working Pressure 25.8 bar

Accuracy (Dependant on proper sizing of gauge and tank config.) Direct-reading dials: ±5% Hall Effect Module Output: ±4%

Approvals Gauge is UL listed for LP Gas service applications. R3D Module is UL Classified as instrinsically safe.

105

Page 106: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

The trademarks and logos used on this page are protected by commercial rights and are registered trademarks of Rego®. Europump International® is not affiliated with any of them.

Page 107: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

relief valves

Part Number

Start To Discharge

Setting PSIG

Container CorrectionM. NPT

Flow Capacity SCFM/Air* Tank Surface

Area up to:**

Accessories

UL (at 120% of Set Pressure)

ASME (at 120% of Set Pressure) Protective Cap Pipeaway Adapter

7534B 1252"

6.025 - 319 sq. ft.7534-40 7534-20***

7534G 250 11.675 10.422 708 sq. ft.

* Flow rates shown are for bare relief valves. Adapters and pipeways will reduce flow as discussed in the forewording information.** Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME - whichever is larger.*** 3" F. NPT outlet connection.

Part Number

Start To Discharge

Setting PSIG

Container Type

Container Connection

M. NPT

Overall Height

(Approx.)

Wrench Hex

Section

Flow CapacitySCFM/Air*

Tank Surface Area up to:***

Accessories

UL (at 120% of Set

Pressure)

ECII® rated at 480 PSIG**

Protective Cap

Pipeway Adapter

Part Number Outlet Size

3127G250 ASME

1/4" 1 31/32" 7/8" 295- - -

3129G 1/2" 2 10/32" 11/8" 465

3127K

375 DOT

1/4" 1 31/32" 7/8"

-

450 100 lbs/propane 3129-10 1/2" F. NPT

3129K 1/2" 2 10/32" 11/8" 780 200 lbs/propane

-

3129-10 1/2" F. NPT

* Flow rates shown are for bare relief valves. Adapters and pipeways will reduce flow as discussed in the forewording information.** Not UL or ASME rated. ECII® rated at 480 PSIG.*** Meets DOT requirements.

image model / type description

003127GExternal Hydrostatic Relief Valve 1/4" M. NPT

(Start To Discharge Setting PSIG 250)Container type: ASME

003127KExternal Hydrostatic Relief Valve 1/4" M. NPT

(Start To Discharge Setting PSIG 375)Container type: DOT

003129GExternal Hydrostatic Relief Valve 1/2" M. NPT

(Start To Discharge Setting PSIG 250)Container type: ASME

003129KExternal Hydrostatic Relief Valve 1/2" M. NPT

(Start To Discharge Setting PSIG 375)Container type: DOT

image model / type description

007534G Semi Internal Pressure Relief Valve 2" M. NPT(Start To Discharge Setting PSIG 250)

107

Page 108: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Part Number

Inlet Connection M. NPT

(A)

Outlet Connection F. NPT

(B)

Wrench Hex Flats(C)

Effective Length (Approx.)

(D)

Threaded End to Port

(E)

Approximate Closing Flow*

Liquid(GPM Propane)

Vapor SCFH (Propane)

25 PSIG Inlet

100 PSIG Inlet

2884D 3/4" 1/4" 11/16" 11/4" 11/16" N/A 60 110

* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up and slightly less with outlet down.NOTE: Multiply flow rate by .94 to determine liquid butane flow.

Part Number

Inlet Connection M. NPT

(A)

Outlet Connection F. NPT

(B)

Wrench Hex Flats(C)

Effective Length (Approx.)

(D)Material

Approximate Closing Flow*

Liquid(GPM Propane)

Vapor SCFH (Propane)

25 PSIG Inlet

100 PSIG Inlet

12472

3/4" 3/4" 13/8" 13/8"Brass

4 1.050 1.700

3272E 10 2.100 3.700

3272F 15 2.800 5.000

3272G20 3.700 6.900

A3272G Steel

3282A

11/4" 11/4" 2" 116/18"Brass

30 5.850 10.000

3282B 40 7.600 13.600

3282C50 9.000 16.300

A3282C Steel

757411/2" 11/2" 21/4" 13/4"

Brass

90 15.200 28.100

7574L 70 14.000 25.000

3292A

2" 2" 27/8" 17/8"

75 14.200 24.800A3292A Steel

3292B Brass100 18.100 32.700

A3292BSteel

A3292C 122 22.100 37.600

* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up and slightly less with outlet down.

excess flow valvesimage model / type description

002884D Excess Flow Valve 3/4" M. NPT x 1/4" F. NPT

image model / type description

003272G Excess Flow Valve 3/4" M. NPT x 3/4" F. NPT BrassLiquid (GPM Propane) 20

A003292C Excess Flow Valve 2" M. NPT x 2" F. NPT SteelLiquid (GPM Propane) 122

108

Page 109: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

Part NumberInlet/Outlet Connections

NPT. F

Disconnect Force Approx.

(lbs)

Reconnect Force Approx.

(lbs)

Length of Valve

LP-Gas Liquid Flow Capacity at Various Differential Pressures (GPM)*

5 PSIG 10 PSIG 25 PSIG 50 PSIG

A2141A63/4" 130 80 37/8" 11 16 25 36

A2141A6L*

A2141A81" 75 50 49/16" 21 30 47 67

A2141A8L*

A2141A10 11/4" 160 25 55/8" 52 75 120 170

A2141A16 2" 300 50 145/16" 250 350 550 750

* To determine NH3 flow capacity, multiply by .90.

pull-away valves

image model / type description

A002141A6L** Pull‐Away Valves 3/4" F. NPT with steel galvanized cable

A002141A8 Pull‐Away Valves 1" F. NPT

109

Page 110: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

The trademarks and logos used on this page are protected by commercial rights and are registered trademarks of Geca®. Europump International® is not affiliated with any of them.

Page 111: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

gamma se230-se233-se296 natural gas and lpg detector with acoustic alarm and output relay

The IMQ certification in accordance to the standards CEI EN50194 guarantees the quality of these gas detectors.

In presence of gas concentrations, the alarm lights up and emits a loud signal, and thanks to the output relay it is possible to manage the closing of the solenoid gas valve.

se138 standalone industrial gas detector with replaceable cartridge sensor atex certified for zone 1

The gas detectors in explosion-proof housing for use in potentially explosive atmospheres are Certificated CESI 03 ATEX 323 X extension n. 2.11 (31/04/2011) updated to EN60079-0: 2009 and EN60079-1: 2007 standards and characterized by the following Ex marking (Directive 9479/EC):

standard specification

• Standards certified: EN 50194.

• Power supply: 230 Vac (±10%) e 12Vdc.

• Absorption: 4VA (230Vca).

• Sensor: Catalytic.

• Alarm level: 10% LEL - Measuring range: 0÷20% LEL.

• Output relay: exchange contacts 3A 250Vac.

• IP Rating: IP42.

standard specification

• Ex marking : II 2G Ex d IIC T6 Gb.

• No. 3 Alarm relays solid state type. MAX resistive load 24V/1A SPST.

• No. 1 Fault relay solid state type. MAX resistive load 24V/1A SPST.

• Alarm levels (relays) programmables via DIP-Switch.

• No. 1 linear 4÷20 mA current output.

• Terminals plug-in polarized type.

gas detectors

111

Page 112: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

gas electro-valves n.c. 6 bar dimensions from 1/2" to 2"

Gas solenoid valves are designed to be combined with any gas detection system, that allow shutting off of the main outlet when an emergency situation is detected.

The solenoid valves are installed on the gas piping and attached with a gas detector. They interrupt the gas flow in an emergency situation.

The electro-valve is generally connected behind a filter, upstream of the regulation apparatus and preferably outside the measurement zone. It should be installed with the arrow facing the user. To reset the solenoid valve, check that the coil is receiving current and pull the reset knob after having unscrewed the protection cap, and screw it back in when the operation is finished.

standard specification

• Power supply: 230 Vca – 24 Vcc/Vca – 12 Vcc/Vca

• Body: brass, painted

• Working temperature: -15°C / +70°C

• Closing time: < 1 sec

• Max pressure: 6 bar

• Protection level: IP65

• Connections: ISO 228/1 thread

gas solenoid valve

112

Page 113: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

notes

Page 114: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

notes

Page 115: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

contact

Europump International® is a worldwide network with a presence in many regions of the world, helping us serve our customers as efficiently as possible. For more information, feel free to contact any of our offices from the following regions:

EUROPUMP ITALIA SRLVia Georges Bizet 36G

20092 Cinisello Balsamo (MI)ITALY

Tel: +39 02 612 99144Fax: +39 02 407 [email protected]

EUROPUMP AKY. TECH. SAN. VE TIC. A.S.Ist. Mermerciler San. Sit.18. Cad. 22. Sok. No:32

Koseler KoyuDilovasi Kocaeli

TURKEY

Tel: +90 216 365 35 70Fax: +90 216 365 35 72

[email protected]

EUROPUMP POLSKA SPÓŁKA Z. O. O.86-300 Grudziądz ul. Rapackiego 37

POLAND

Tel: +48 56 64 11 666Fax: + 48 56 64 11 665

[email protected]

Page 116: 2019europump.com/images/Catalog2019.pdf · communication protocol Wyn-Dart Wyn-Dart Wyn-Dart communication interface 2 wire current loop 2 wire current loop 2 wire current loop frame

w w w . e u r o p u m p . c o m