Page 1: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

www.FTFgroup.us

the future of space conditioning

Company Profile

Page 2: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

ContentsCompany Overview 3Climate Testing Facility 5Acoustic Testing Facility 7Photometric Testing Facilities 8Bespoke Manufacturing 9X-Wing®

“Radiant Passive” Chilled Beams 10Active Chilled Beam Principles 12Multiservice Chilled Beams 14Chilled Ceilings - First Generation 16Radiant Heating 18Acoustic Lighting and Heating Rafts 20Large Project Experience 21Project References 22Industry Associations 26Global Offices 27

Page 3: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

Company Overview

3

Frenger Systems is a wholly owned subsidiary of the FTF Group and is trading with the United States of America as FTF Group Climate. Frenger Systems is a renowned specialist manufacturer of space conditioning products for indoorclimate/environments.Frengerhasextensiveexperiencedatingbacksome80yearsandisattheforefrontof the design, development and manufacture of water driven cooling and heating technologies. Over the years Frenger has earned an enviable reputation as a dependable supply partnercapableofdevelopingeffectivespaceconditioningsolutionsforthemostcomplexofprojects.

In1962Frengerdesigned,suppliedandinstalledthe“World’sLargest Radiant Chilled Ceiling” system which was revolutionaryatthetime.Thisconsistedof1.88millionsquarefootofradiantchilledceilingoverthe27storeysoftheShellOilheadquarters,situatedontheriverThamesinLondon,UK.TheThameswaterwasusedviasecondaryheatexchangersto cool the water that circulated on a closed circuit around the ceilingswithinthebuilding.Thisbuildingwasalsothefirstfullysealed air conditioned building in Europe. This installation is stilloperatingaftersome50yearsandisatestamenttotheintegrityoftheproductandtoFrenger’sdesigncapabilities.

Frenger also pioneered with the supply of Chilled Beam and ceilingtechnologytoAustraliain2003andwasforthefirsteverbuildingtobeawardeda5starenergyrating.Thebuildingwascalled“TheBond”,situatedinSydneyanddevelopedbyBovisLendLease(BLL);whomarenowknownas Lend Lease.

BLL spent considerable time researching Chilled Beam and ceilingTechnologyworldwideandundertookagreatamountof due diligence before selecting a Chilled Beam supplier for theirthenhighlyconfidentialbuilding(“TheBond”,30HicksonRoad,Sydney).ManyofBLL’scompetitionthoughtthatitwasnotpossibletogaina5starenergyratingandassuchBLLknewthatthestakeswereextremelyhighandmuchdepended upon their success. Frenger were then chosen by BLL to play an integral part of what transpired to be a successfulprocessandthebuildingisstill,some10yearslater,functioningwellandcopingwithexternaltemperaturesintheregionof104°Fforsomepartsoftheyear.

Since2003FrengerhassuppliedChilledBeamtechnologytomany5starandeven6starenergyratedbuildingsmorerecently in Australasia, some of these can be seen on pages 23to25ofthisCompanyProfileunderthetitleof“ProjectReferences”.

InadditiontoFrengerprovidingthefirstChilledCeilingin1962andprovidingthefirstever5starenergyratedbuildingin2003,FrengerpioneeredwithMultiServiceChilledBeams(“MSCB’s”)intheUKandhavingdesigned,suppliedandofteninstalledmanysuccessfulMSCBprojects.FrengerwereselectedbyBlythandBlythforthe£160MillionPound(Circa$250MillionUSDollars)refurbishmentofLondon&Regionals“55BakerStreet”buildingwhichinvolvedHBGConstruction(nowknownasBAMConstruction)amalgamating 3 separate buildings into one enormous building with 2 central atriums and two internal streets.

Page 4: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

4

Frengerdesigned,ClimacticTested(fullscalelaboratorymockup),manufacturedandinstalledtheseMSCB’sin2007whichrepresentedcirca£7millionGBP(Circa$10.8millionUSDollars)ordervaluetoFrenger.Thiswasandstillistheworld’slargestMSCBinstallation.HBG’sannualawardforBestSub-Contractorwas also awarded to Frenger and Frenger also gained various letters of commendation from the Client, the Consulting Engineers and the Main Contractor regards their performance of theirinvolvementwiththe£160millionGBP(Circa$250millionUSDollars)refurbishmentproject.DetailsofthisandothermajorprojectsbyFrengercanbefoundonpage22ofthisCompanyProfileundertheheading“LargeProjectexperience”.

The reason as to why Frenger are chosen for such important highprofileandcomplexprojectsforthespaceconditioning/indoor climate is because Frenger:

Havethehighestperformingproductsonthemarket.Excellentproductquality. Always deliver on what is promised and never over

state/oversell.Haveeverythingin-housetosubstantiateallaspectsofthe

indoor environment.Manufactureasmanykeyitemsin-houseaspossibleto

keepfullcontrol.Takeownershiptodeliverwhatisrequired,ontime,on

budgetandtothecorrectspecification.

FrengeremploysprofessionallyqualifiedMechanicalEngineers,ElectricalEngineers,LightingDesigners,BuildingServicesEngineersandProjectManagerstogivecustomersanunrivalledlevelofinhouseexpertiseforChilledBeamandMultiserviceChilled Beam (MSCB) technologies. Frenger builds sound business relationships with clients and has won many accolades tothisextent,whichhaswarrantedFrengerajustifiablereputationfordeliveringcomplexprojectsontime,withinbudgetandtospecification,everytime.AllaspectsofthebusinessareaccreditedtoBSENISO9001:2008andareregularlyauditedbythe British Standards Institution (BSI). DuetoFrenger’scontinuingsuccess,theshareholdersofitsparentcompany,theFTFGroup,providedFrengerin2009withoneoftheirfullyownedoutrightmultimillionGBPbuildingsforfitoutasanewUKTechnicalFacility.ThebuildingissituatedintheEast Midlands and holds a prominent position on the prestigious PrideParkcorporatebusinesscentre.Frengerhaveequippedthisbuildingtosupportalltechnicalaspectsofthecompanies’world wide operations.

ThenewheadquartersarefullyspaceconditionedwithvariousdifferenttypesofChilledBeam,MSCBandChilledCeilingtechnologies, each controlled by a full building management system(BMS)whichcandemonstrateexactlyhowwelleachchilledsystemisfunctioningandtheirefficiencies.ThisbuildingalsohousesFrenger’s:

Specialist manufacturingState-of-the-artClimaticTestfacilitiesPhotometrictestlaboratories Acoustic laboratory Lighting design capabilities2D&3DCADoperationsComputationalfluiddynamicsSolidworks.

Page 5: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

Climate Testing Facility

5

The FTF Group has 3 number climatic test laboratories locatedatit’stechnicalcentrewhichislocatedattheprestigiousPridePark,Derby,England.

These purpose designed and built laboratories have nominal internaldimensionsof20.7ft(L)x18.7ft(W)x10.8ft(H)andeachenvironmentalchamberincludesit’sownthermalwallsothat both core and perimeter zones can be physically mod-elled in any of the rigs.

All3environmentalchambersarefixedinsizehoweverthefitmentofpartitionwallingandfalseceilingscanbepositionedtomatchthephysicalconstraintsofaprojectspecificinstallation.

CatalogueData-StandardProductAllFTFGroup’sproductsaredesignedbyFTFGroup’sin-houseResearchandDevelopment(R&D)department.Once any new product is ready for mass production these are testedin-housetothefollowingBritishStandardsforCatalogueDatatobecollated/published:

BSEN14240:2004–Ventilationforbuildings–Chilled ceilings–Testingandrating.BSEN14518:2005 –Ventilationforbuildings–Chilled

beams–Testingandratingof passive chilled beams.BSEN15116:2008 –Ventilationinbuildings–Chilled

beams–Testingandratingof active chilled beams.BSEN14037-2 –RadiantPanelTestMethodsfor

Thermal Output.ISO7730 –Ergonomicsoftheindoor

environment.ASHRAE55-2010–ThermalEnvironmental

conditions for human occupancy.

Inadditiontotheabovein-housecomprehensivetestingwhichutilisesstateoftheartequipmentandBSRIAcalibrated instrumentation to reduce the amount of uncertainty toanaccuracyof+/-2.5%,TheFTFGroup(s)subsidiaryalsosubscribetothirdpartlyValidationTestingbyEurovent.

Euroventcertificationtestingisonlyforperformanceandtakesnoaccountoftheindoorenvironment,whereasallFTFGroup testing and published catalogue data is compliant toISO7730,ergonomicsoftheindoorenvironmentandASHRAE55-2010,thermalenvironmentalconditionsforhuman occupancy to ensure that occupancy comfort is maintained to the highest of standards.

1 of 3 Climatic Test Laboratories

Page 6: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

6

Projectspecificmock-uptestingisavaluabletoolwhichallowsthe Client to fully asses the proposed system and determine theresultingindoorqualityandcomfortconditions;thephysicalmodeling is achieved by installing a full scale representation of a buildingzonecompletewithinternal&externalheatgains(Lighting,SmallPower,Occupancy&SolarGains).

Theinstalledmock-upenablestheclienttoverifythefollowing:Productperformanceunderprojectspecificconditions Spatial air temperature distribution Spatial air velocitiesExperiencethermalcomfortProjectspecificaestheticsExperiencelightinglevels(whererelevant)Investigatethespecificdesignandallowthesystemtobe

enhanced.

Theproject-specificinstallationandtestisnormallyconductedtoverify:

ProductcapacityunderdesignconditionsComfortlevels -Airtemperaturedistribution

-Thermalstratification -Draftrisk -RadianttemperatureanalysisSmoketestvideoillustratingairmovement

Active MSCB Room Temperature

ActiveMSCBAirVelocity RadiantPassiveMSCBAirVelocity

RadiantPassiveMSCBRoomTemperature

Page 7: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

Acoustic Testing Facility

7

TheAcousticTestRoomatFTFGroup’sTechnicalFacilityisahemi-anechoicchamberwhichutilisessoundabsorbingacoustic foam material in the shape of wedges to provide an echo free zone for acoustic measurement; the height of the acoustic foam wedges has a direct relationship with the maximumabsorptionfrequency,henceFTFGrouphadthewedgesspecificallydesignedtooptimisethesoundabsorptionatthepeakfrequencynormallyfoundwithouractive chilled beam products.

The use of acoustic absorbing material within the test room providesthesimulationofaquietopenspacewithout“reflections”whichhelpstoensuresoundmeasurementsfromthe sound source are accurate, in addition the acoustic materialalsohelpsreduceexternalnoiseenteringthetestroom meaning that relatively low levels of sound can be accurately measured.

TheacousticfacilitiesallowFTFGrouptoprovideexpressin-housesoundevaluationsothatallproducts,evenprojectspecificdesignscanbeassessedandoptimised.

To ensure accuracy FTF Group only use Class 1 measurementequipmentwhichallowssoundlevelmeasurementstobetakenat11differentoctavebandsbetween16Hzto16kHz,withA,CandZ(un-weighted)simultaneous weightings.

In addition to the above, FTF Group also send their new products for specialist third party Acoustic Testing. The results of which are very close and within measurement tolerances to thatofFTFGroup’sin-housemeasurementofsound.

Page 8: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

PhotometricTestingFacilities

8

ThePhotometrictestlaboratoriesatFTFGroupareusedto evaluate the performance of luminaires. To measure the performance, it is necessary to obtain values of light intensity distribution from the luminaire. These light intensity distributions are used to mathematically model the lighting distribution envelope of a particular luminaire. This distribution alongwiththeluminairesefficacyallowsforthegenerationofa digital distribution that is the basis of the usual industry standardelectronicfileformat.Inordertoassesstheefficacyoftheluminaireitisarequirementtocomparetheperformance of the luminaire against either a calibrated light sourceforabsoluteoutputoragainstthe“bare”lightsourcefor a relative performance ratio.

The industry uses both methods. Generally absolute lumen outputs are used for solid state lighting sources and relative lighting output ratios (LOR) are used for the more traditional sources.WheretheLORmethodischosenthenpublishedLampmanufacturer’sdataisusedtocalculateactuallightinglevels in a design.

The intensity distribution is obtained by the use of a Goniophotometer to measure the intensity of light emitted fromthesurfaceofthefittingatpre-determinedangles.Thelight intensity is measured using either a photometer with a correctivespectralresponsefiltertomatchtheCIEstandardobservercurvesorourspectrometerforLEDsources.

Luminaire outputs are measured using our integrating sphere for smaller luminaires or our large integrator room for large fittingsandMultiServiceChilledBeams.Forbothmethodswecanusetraceablecalibratedradiantfluxstandardsforabsolute comparisons.

Alltestsuseappropriateequipmenttomeasureandcontrolthe characteristics of the luminaire and include air temperature measurements, luminaire supply voltage, luminaire current and power. Thermal characteristics of luminaire components can be recorded during the testing processasrequired.

Afulltestreportiscompiledandsuppliedin“locked”PDFformat.Dataiscollectedandcorrelatedusingapplicablesoftware and is presented electronically to suit, usually in Eulumdat,CIBSETM14orIESNstandardfileformat.

FTF Group conduct photometric tests in accordance with CIE 127:2007andBSEN13032-1andsoundengineeringpracticeasapplicable.DuringthecourseofthesetestssuitabletemperaturemeasurementsofpartsofLEDscanberecorded. These recorded and plotted temperature distributionscanbeusedtoprovidefeedbackandhelpoptimise the light output of solid state light source based luminaireswhichareoftenfoundtobesensitivetojunctiontemperatures.

Page 9: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

9

BespokeManufacturingTheCompanyhasthemanufacturingcapabilityrequiredtodeliverthemostcomplexofbespokesolutions.Facilitiesinclude the latest full CNC bending centers and machining equipment,togetherwithadedicatedpowder-coatpaintplant to paint all of the components of the multiservice chilled beam.

Page 10: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

FTFGrouphasextensiveexperienceinthedesignandmanufactureof“Radiant”/ConvectivePassiveChilledBeamsolutions;providingdiscreetandcost-effectivespaceconditioning to commercial, educational and healthcare environments.Overthepast20yearsproductshavebeensuppliedtomajorprojectsthroughoutEurope,andasfarafieldasAustralia.FTFGroup’s“Radiant”/ConvectivePassiveChilledBeamsofferahybridbetweenconventionalpassive chilled beams and radiant chilled ceilings.

Low maintenance cooling systems“Radiant”/ConvectivePassiveChilledBeamsprovideanefficientmeansofcoolingand,withnomovingparts,requirelittle maintenance. This in turn ensures lower running costs. They can be installed above perforated or microperforated metalceilingstoprovideupto43BTU/hr/ftofcost-effectivecoolingwithminimalcontrolrequirements.

This type of solution does not create any noise or drafts in officeenvironments,andimproveboththecomfortandisreported to increase the productivity of the occupants. The system ensures a very low degree of air movement below the chilledbeamsinordertocomplywithASHRAE55-2010standardof40fpmandISO7730standardoflessthan50fpm.

OperationWhencoldwaterpassesthroughour“Radiant”/ConvectivePassiveChilledBeamthewarmroomairiscooledagainstthesurfaces. This chilled air, which then becomes heavier, then streams through the punched louvres in the radiant beam and percolates through the small ceiling perforations into space below (when concealed). In this way air is circulated within the room, with warm air from the room space being continually replaced by cooled air.

In addition to this convective process, the cold surfaces of the beam also absorb heat radiation from the building occupants andthewarmersurroundingsurfaces.Theradiantquotientisapproximately40%ofthetotalcoolingeffect(theother60%ofcoolingbeinggeneratedbytheconvectivecoolingeffectdescribedabove).Theabilityofour“Radiant”/ConvectivePassiveChilledBeamtoalsocoolbyradiantabsorptionmeansthat,whencomparedtoafinnedtubebattery,ourbeamcandeliver40%morecoolingwithoutanyadditionalriskofdraft.

In addition to the convective heat transfer common to all passivechilledbeams,theradianteffectoftheproductsalsocools the metal ceiling system(secondary radiation), which in turnre-radiatesthiscoolingeffectintotheroom.Theradianteffectofthebeamalsoprovidesamorecomfortableenvironment for the building occupants and even less chanceofanydrafts(draftriskratingisreduced).Thesystemprovidesthecomfortandaestheticbenefitsofradiantchilledceilingsatasignificantlylowercostandwhilstmaintainingthe higher cooling capacities associated with chilled beam installations.

10

X-Wing® “RadiantPassive”ChilledBeams

X-Wing® (Radiant Chilled Beam)

Convective Only Fincoil Battery

Radiant Chilled Beam

Radiant Beam

Air Velocity(ft/min)

66’55’50’40’35’25’15’10’4’

66’55’50’40’35’25’15’10’4’

FincoilBattery

Air Velocity(ft/min)

47/8”

Page 11: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

11

Composition and Manufacture

FTFGroup’s“Radiant”/ConvectivePassiveChilledBeamsareconstructed from coiled copper which is formed into serpentine coilsutilisingfullCNC,state-of-the-artautomateddecoilingandbendingmachines.Thisprocesseliminatestheriskofanyleaksastherearenojointsinthecopperwatercircuitoftheproduct.Thealuminumradiant“wings”whichmakeupthecoolingsurfacearemechanicallyfixedaroundthecoppertubeserpentineonepiececoilinwhichthecoldwateristransportedtoprovide100%encapsulation of the waterways for optimum transfer of energy from the radiant wings to the copper waterways. Both the copper tubingandaluminumwingsare100%recyclable.

Dimensions

FTFGroup“Radiant”/ConvectivePassiveChilledBeamsarecompact and versatile in the way that they can be mounted and located.Availableindifferentwidthsandlengthsandislessthan5”deep,systemscanbeinstalledin10”ceilingvoids.

Benefitsof“Radiant”/ConvectiveChilledBeams

Nojointsinthecoppertubecoil-noriskofleaks No noise or drafts; improved occupancy comfort and

productivity NomovingpartsequatestoreducedmaintenancecostsCapitalcostsnowcomparableand/ormorecompetitivethan

traditional AC systems Improvedefficienciestranslatestolowerrunningcosts Can be installed within shallow ceiling voids

FTFGroup’suniquefeatures

Lessthan5”deepOffersradiantandconvectivecoolingWilloperateefficientlyaboveamicro-perforatedceilingCanbeinstalledwithina10”deeptotalceilingconstruction,if

necesary due to height restrictionsMinimalmaintenanceduetoabsenceofcloselyspacedfins

asassociatedwithfincoilbatterypassivebeamsVerylowairmovementbelowchilledbeamCoolingcapacityupto43BTU/hr/ftabovemetalceilingperfo

ratedto28%freeareaand0.094”or0.118”perforation.

CommercialOffices

FTFGroup’srangeof“Radiant”/ConvectivePassiveChilledBeams installed above perforated metal ceiling systems is a tried andtestedsolutionusedinmanyhigh-profileprojectsintheUK,Europe and Australia. The system provides high levels of comfort for occupants, with minimal control and maintenance requirements.

Furthermore,theRadiant/Convectivenatureoftheproductmeans that it is insensitive to the position of heat sources, and can be utilised with standard ceiling perforation patterns for great-ly improved aesthetics.

Maintenance

FTFGroup’srangeof“Radiant”/ConvectivePassiveChilledBeamsareextremelyeasytoclean,requiringasimplewipewitha damp cloth.

Page 12: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

ActiveChilledBeamPrinciples

12

FTF Group manufactures and supplies a range of active chilled beams with the highest performance curves on the market.FTFGroupdrawuponhighperformancetechnologiesandpatented/registereddesignfeaturestode-liverefficientcoolingtocommercial,educationalandhealth-care environments.

EfficientandquietspaceconditioningFTFGroup’spatentedbatteryangles,airchambergeometryanduniqueburstnozzlestripenablestheirActiveChilledBeams to deliver unrivalled levels of cooling capacity with a given air volume whilst ensuring that the reconditioned air is delivered into the space in a controlled manner that best suits theapplication.Theunitsaresoefficientthattheycanprovidecoolinginexcessof73BTU/hr/ftwithfreshairsupplyofaslittleas0.2CFM/ft2.

Units are designed to integrate into suspended ceiling systems.Theyfiteasilyintothemostcommonceilingdesignsand have removable underplates that can be perforated to matchperforatedmetalceilingswhererequiredortobestcomplimentmineralfibreorplasterboardceilings.Theseremovable underplates provide access for maintenance, although maintenance is minimal given that there are no moving parts.

FTFGroup’sActiveBeamsarealsodesignedtoensurelownoise levels. They incorporate a patented air chamber burst nozzle strip technology which delivers cool air to the room veryquietly,andmakesthemsuitablefordiscreetinstallationinhotels,offices,hospitals,schoolsandbanks.Airdeliverycan be accurately controlled so that air velocities do not exceed40fpm,ensuringcompliancewithASHRAE55-2010and50fpmforISO7730compliancebyuseofdiscreteairdeflec-tor vanes mounted as part of the patented and registered designed air chambers. Beams can be supplied with factory fittedcondensationsensors.

OperationAnactivechilledbeamisessentiallyawater-driven,ceiling-mountedinductionunit.Itusesasupplyoffreshventilation air to induce warm room air (recirculated air) throughtheunit’scoolingfincoilbattery.TheFTFGroupbeamisabletoinduceandcondition4-5timesasmuchroomairasfreshairsupplied.Conditionedairisthenquietlyreintroducedintotheroom,entrainingtotheceilingratherthanbeingjettedoutdirectlybelowthebeam,thankstopatentedairchamberdesignthatproducesaCoandaeffect.Thepatentednozzletechnology also allows the Company to determineandfactory-settheairflowdispersioncharacteristics of each unit. Beams can deliver a cooling capacityinexcessof3142BTU/hr.

Composition and manufactureAiriscooledasitpassesthroughafincoilbattery,whichcomprisesaluminumfinswithcoppertubesthroughwhichwaterpasses.Theheatoftheroomistakeninthroughthealuminumfins,andtransferredintothewatercircuitthroughthe copper tube and transported away via the circulating chilledwaterbacktoacentralchillerunit.Activechilledbeamshave no moving parts, and as such maintenance costs are minimal.

13 3/8”

Cornice™ One way ceiling discharge

Ultima300™-Onewayceilingdischarge

81/4”

Page 13: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

13

DimensionsTheFTFGroupunitshaveside-mountedairchambersthatfacilitate high cooling in very compact dimensions. Our slim line beamsrangewhichcanoperatewithupto106CFMandisjust5.2”deep,whereasourHighOutputbeamrangewhichcanoperatewithupto169.6CFMandisjust81/4”deep.Bothofwhichcanachieve3142BTU/hrtotalcooling.

Benefitsofactivechilledbeams Units can deliver cooling, heating, fresh air and lighting Arangeofbeamswith1-way,2-wayand360Degreeair

discharge NomovingpartsequatestoreducedmaintenancecostsCapitalcostsnowcomparableand/orlessthantraditional

air conditioning systems Improvedefficienciestranslatetolowerrunningcosts Can be installed in shallow ceiling voidsUnitscandelivercoolingcapacitiesinexcessof58BTU/hr/ft

FTFGroup’suniquefeatures All recirculated air is induced through the removable

underplateandconsequentlythereisnoneedforareturn air path via the ceiling void AdvancedPatentedbatteryangletechnology

deliversinductionratiosof5:1,enablingeffectivecoolingatsupplyairratesaslowas0.2CFM/ft2Patentedburstnozzlestripsdesignresultinquiet op-

eration AdvancedairchamberdesigncreatesaCoandaeffect,with

air entraining to the ceiling for improved occupancy comfort levels

Registered designs for concealed air discharge vanes provide“fanshapeddistribution”technologyasstandardwhichreducestheriskofhighairspeedsintheoccupied zone providing higher levels of thermal comfort

Air delivery can be accurately controlled such that velocitiesdonotexceed40fpmtoensurecompliancetoASHRAE55-2010and50fpmfortheEuropeanStandardISO7730

AirDistributionFTFGroup’srangeofActiveChilledBeamshavebeenspecificallydesignedtodeliverairintothespaceinacontrolledandpredictablemanner.AllbeamscreateaCoandaeffectintheunit which encourages the supplied air to entrain to the ceiling or soffit,furthermore,unitscanbemanufacturedwithvaryingthrowcharacteristics(short,mediumorlong)andevenwithdifferentairdelivery characteristics from either side of the unit, or at one end ofaunitifrequired.

Air distribution and comfort levels are determined by many factors; supply air temperature, air volume, air pressure, air directionandentrainment(Coandaeffect)andbeamspacing.ExtensivelaboratorytestshavebeenundertakenbyFTFGroupintheirinhousestate-of-the-artclimatictestlaboratories,todevelop a library of empirical data presented in the form of scatter diagrams, which enables the designer to select the most appropriateproductconfigurationforanygivencondition.

MaintenanceAll units are provided with simple access to the cooling battery throughtheremovableunderplate-thereisnorequirementtoaccess the ceiling void for maintenance or cleaning.

Compact™ Two way discharge

Ultima™ Two way discharge

81/4”

51/4”

9”-101/2”

EcoHQ™ Two way discharge

Halo™360degreedischargepattern

9”

Page 14: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

Multiservice Chilled Beams

14

FTF Group manufactures and supplies multiservice chilled beams (MSCBs). These integrated building services units provideflexiblespaceconditioningthatcanbetailoredintermsofappearanceandtheservicesprovided,inordertomeetprojectspecificrequirements.Inthiswaytheyhelptocreateattractive,comfortableandproductiveworkingenvironments.

FlexiblebuildingserviceunitsA full range of building services can be incorporated within a FTF Group multiservice chilled beam, including:

Cooling&heating Fresh air supply Uplighting, downlighting and emergency lightingBMSsensors,controlvalves&condensationdetectorsAccommodatefirealarmsandsprinklersystems Acoustic insulationPipework,ductwork&compartmentaltrunkingAccommodatePAandVAspeakersystems

Bringing several services together in an integrated MSCB unit means that the physical dimensions of the unit can be optimised toenableuseinspaceswherethefloor-to-slabheightisminimal.Theconceptalsoprovidesthespecifierwithasinglesourceofresponsibility for the design, supply and integration of all services “prefabricated”offsiteinacontrolledenvironment,reducingcostsandon-sitetime.

OperationMSCB’scanutiliseeither“Radiant”passiveorActivechilledbeam technologies. The cooling units are integrated into perforated architectural casings with either central or side-mountedlighting.Lightingoptionsarevariedandcouldbedirect,indirect,acombinationdirectandindirect,T5fluorescent,LED’sorcontinousextrudedlightingopticsofanyshapeandsizetosuitthearchitecturalaspirationsoftheproject.CompletedMSCB’sarefactorytestedanddeliveredtositefor“plugandplay”mechanicalandelectricalconnection/installation.

FTFGroup’spassiveMSCButilisethecompany’s“Radiant”/Convective products to provide comfortable cooling through a combination of convective and radiant heat transfer processes; warm room air is cooled through contact with the chilled beam anddiffusedintothespacethroughtheperforatedunderplate,the beam casing is also cooled via secondary radiation and thus absorbing heat from the warmer occupants. This type of passive cooling provides the best possible combination of high cooling capacitiesandexceptionlevelsofoccupancycomfortwithminimal maintenance.

WherethereisaneedtousetheMSCBtodeliverfreshairintothespace,thenFTFGroup’sSlimLineorHighOutputActivebeamproductswillformthebasisforthecompany’sactiveMSCB’s.Activebeamsutilisethedeliveryofsupplyairtoinducewarmerroomairthroughtheunit’scoolingbattery.ThetechnologyemployedinFTFGroup’sactivechilledbeamsensures high cooling capacity with low supply air volumes, coupledwithaquietandcontrolleddeliveryofairforoptimalcomfort.

Both types of MSCB are designed for simple installation; electrical,waterandairconnectionscanbeinter-linkedfromunittounitbysimple“PlugandPlay”connectionstoreduceon-sitetime to a minimum.

Active MSCB

RadiantPassiveMSCB

RadiantPassiveMSCB

Active MSCB

1 of 3 Climatic Test Laboratories

Page 15: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

15

Finish and appearanceMSCB’sofferanalternativetothemonolithicceilingsthathavebecomecommonplaceinofficedevelopments,providingattractive yet functional building services installations. The appearance of each beam can be customised in terms of shape, dimensions, lighting options, colour and perforation pattern to meettheclient’sparticularrequirements.

Technical SupportFTFGroupcandrawuponmanyyearsexperienceinthedesignand manufacture of cooling systems which combine the highestlevelsofoccupancycomfortwithclass-leadingdesign.FTFGrouphasinhousespecialistmanufacturing,state-of-the-art test facilities and various design operations for all aspects of every service within their MSCB units.

FTFGroupcanofferclientsarangeofsupportservices;

Climate simulations to predict comfort levels Full lighting design including light level calculations and

luminairedevelopmenttoLG3/LG7requirementsCADdraftingand3DrenderingofMSCBsintheenvironmentSolidworksCFDModeling Energy Modeling BIM Software Revit

BenefitsofMSCB’sIdealwherefloor-to-slabheightisminimalLowrunningcostswithminimalmaintenancerequirements Integration of several services in a single unit reduces costs

andsiteprogrammerequirements(”prefabricated”offsite)Highcooling/heatingcapacitiesLownoiseandlowdraftriskmakesforhighcomfortlevelsBeamaestheticcanbecustomisedtoclientrequirements Single point of responsibility for the design, integration,

manufactureandtestingofallservices(”PlugandPlay”)

FTFGroup’suniquebenefits‘In-house’lightingdesignandluminairedevelopmentPassiveMSCBsdelivercoolingviaradiantabsorptionand

convection Active MSCBs deliver high cooling capacities with minimal

supply air volumeConsiderableexperienceinthedesignandsupplyofboth

active and passive types of MSCB Only company whom manufacture inhouse the services

offeredandtoalsohavetheinhousetestfacilitiesforalltheservicesoffered

In-houseTestingFacilities;FTFGroupalsohasthefollowingin-housetestfacilitieswhichenableustodevelopandofferclientswithbespokeMSCBdesigns;

3 number state of the art Climatic Test Laboratories (BSRIA calibrated).2numberPhotometricTestLabsalongwithlightingdesign

inaccordancewithCIE127:2007andBSEN13032-1and sound engineering practice. Acoustictestingsemi-anechoicchamberwhichmeasures

Class1measurementsat11different1/3octavebandsbetween16Hzto16kHz. Active MSCB

RadiantPassiveMSCB

RadiantPassiveMSCB

Active MSCB

Page 16: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

ChilledCeilings-FirstGeneration

16

Introduction&OverviewTechnical Advancements of Chilled Ceilings

Static cooling systems (chilled ceilings) have, over the past 40years,proventhemselvescapableofdeliveringhighlevelsof occupancy comfort at reduced running costs. Frenger designed, supplied and installed the “World’s Largest Radiant Chilled Ceiling” system in 1962; the 175,000 square meter, 27 stories high, Shell Oil headquarters, situated on the River Thames in London. This building was alsothefirstfullysealedairconditionedbuildinginEuropeand was revolutionary at its time as this Frenger Chilled Ceiling used the River Thames water to cool the building down. This was achieved by pumping in cool water from upstreamtoasecondaryheatexchangerwhichinturncooled(tookheatoutofthebuildingby“Radiant”absorption)thebuilding down, then depositing the warmer return water from thesecondaryheatexchangerdownstream.This installation is still operating after nearly 50 years and is a testament to the integrity of the product and to Frenger’s design capabilities. Sincethistimethecoolingrequirementsforatypicalofficeenvironment have increased considerably; higher occupancy densitiesandamuchhigherusageofITequipmenthaveallfueledthisincrease.Itbecameapparentinthemid1990’sthat the cooling capacity of a traditional chilled ceiling was not sufficienttomeettheseincreasedheat-gains,andconsequentlyhigher-capacitypassivechilledbeamfincoilbatterieswereintroducedintoperimeterzonestooffsetthesolar load generated at the building façade.

Althoughfincoilbatteriesprovidedtheextracoolingatlowercostin$/BTUthanthetraditionalradiantchilledceiling,theperimeteraestheticssufferedduetothefincoilbatteriesrequiringlargesizeperforationsandpercentageopenareatoallowair(“convection”)tocirculateandthisalsoreducedoccupancy comfort, due to higher air velocities.

Frengerhoweversawtheopportunitytotakeallthebenefitsfrom a traditional radiant chilled ceiling for radiant cooling, and todevelopa“hybrid”productsolutionthatalsohasthecoolingperformance of convective only passive beams. The hybrid retaineda40%“Radiantcooling”quotienttoyieldsimilaraesthetics as associated with the traditional Radiant Chilled Ceilings, also with low air velocities (for compliance to ISO 7730EuropeanStandardfor“IndoorAirComfortConditions”)anda60%convectionelementforhighoutputcooling.Frenger’s“hybrid”Radiant/ConvectiveChilledBeamsaredetailedonpages10and11.

Theseattractivehighqualityceilingsystemsprovidethebestinoccupancycomfortgiventheirhigh“Radiant”quotient.Approximately 70% of the total cooling is by radiant absorption and the remaining 30% by convection if the back of the tiles are insulated,andcirca55%Radiationand45%Convectionifthecoolingtilesareun-insulated.

ShellOilHQ,RiverThames

Traditional Radiant Chilled Ceiling

“Hybrid”Radiant/ConvectiveChilledBeamCeiling

Page 17: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

17

The cooling tiles are constructed from zinc coated steel which ispolyesterpowdercoatedtowhatevertheprojectcolourrequirementsare.

Aluminiumextrudedheatexchange“pipeseats”arepowder-coatedblackandarebondedtothebackoftheperforatedmetal tile. The tiles can be any size and as large as 551/8inx535/32 in,theseareknownas“MegaTiles”.Thetilesareusuallyinsulatedwithblacktissuefacedmineralwoolpadswithaclass‘O’foilbackingforincreased“Radiant”component(70%Radiation/30%Convection).

Typically the cooling effect is 25.4BTU/hr/ft2 of activated chilled ceiling tiles if insulated and 28.5BU/hr/ft2ofactivatedchilledceilingtilesispossibleiftheceilingtilesareun-insulated,howevertheRadiantcomponentreducestoapproximately55%andtherestofthecoolingisby45%Convection-elementwhenthetilesareun-insulated.

The above listed cooling effects are based on 47.3°F diference between “mean water temperature” (MWT) and the “design room temperature”, known as dTF.

Ordinarily, the ceiling grid (Tartan Grid as shown in the picture aboveright)canrepresentcirca20%oftheoverallceilingifthegridwas60inx60inandeachplaingridwas6inwide.Anallowanceofapproximately8%ofthetotalceilingareabeingtakenupbylightfittingsshouldalsobetakenintoconsiderationwhencalculatingthenettcoolingeffectonthefloorareabelowthetraditionaltypechilledceiling.Theruleofthumbisthatcirca72%ofthetotalceilingarea(roomsize)is to be activated by cooling coils. As such 25.4BTU/hr/ft2 usually netts out at 18.3BTU/hr/ft2 on the floor (insulated tiles)and28.5BTU/hr/ft2nettsoutat20.5BTU/hr/ft2onthefloor(uninsulatedtiles)at15.3dTF.

Shouldmoreoftheceilingberequiredtobeactivatedthisisusuallyachievedbytheuseoflay-inchilledtilesonanexposedgrid,asdetailedinthepictureopposite.

Thesesolutionsarebothenergyefficientandverylowmaintenance and provide high levels of radiant absorption which is the best form of cooling possible.

Should, however more cooling be required than that of a traditional first generation chilled ceiling then see pages 10 and 11 for Frenger’s hybrid of a radiant chilled ceiling and a passive chilled beam to provide the high cooling duties achieved with passive chilled beams, whilst maintaining a good level of radiant absorption (approximately 40% radiant absorption) for improved occupancy comfort.

WithFrenger’sRadiantChilledBeamsthecustomerhasfreedom of choice of ceiling aesthetic and construction type and from any ceiling manufacture even with small perforations(0.094”,0.118”)andlowpercentageopenarea(28%,40%)asassociatedwiththetraditionalcontacttyperadiant chilled ceiling solutions. Exposedgridforlay-in“chilledtiles”

Lay-in“chilledtile”

Tartan Grid Ceiling

Mega“chilledtile”

Page 18: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

18

RadiantHeatingPrinciplesRadiantheatingisahighlyeffectivemethodofheatingaroom.Radiantceilingpanelsheatalloftheroom’ssurfaces(walls,floor,desksetc...),whichinturnheatuptheairwithintheroom.Radiant panels also provide heat directly to the occupants. Consequently,radiantheatingaffordsanextremelycomfortableindoorenvironment,wherethereislittleriskofthepersonfeelingtoo cold under the table or too hot on the head given the surface temperature of the panels. Furthermore, radiant heating focuses ontheareaswhereheatingismostrequired-thecoolestitemsintheroom(usuallytheexternalwallsandwindows).Unlikeconvective heating, an increase in ceiling height does not significantlyincreasetheamountofheatrequired,henceradiantheat is perfect for large open areas with alot of air volume.

Radiant ceiling heating systems function in virtually all types of buildings,frombusyofficeenvironments,largewarehouses,largehospitalstosmallday-carecentres.Thesystemcanbeeasilymodifiedtosuitchangestothewallorfloorlayoutmakingitanextremelyflexibleheatingsolution.

KeyfeaturesofhighlevelRadiantHeating Good thermal climate ReleasesvaluablefloorandwallspaceHeatgoeswhereitismostneeded–reducestheriskofcold

draughts Low temperature gradient of the air within the room from

floortoceiling(32.9°F/ftasopposed35.6°F/ftforfan convective heaters)

ModulaFrenger’sModularadiantpanelisahigh-performingsmoothfacedheatingunit.Copperpipesarefixedrigidlytotherearofeithersteeloraluminiumpanelsviaextrudedaluminiumpipeseats for optimum heat transfer. The panel is designed to be free-hangingorintegratedintoastandardexposedgridceilingsystem.Operatingweightisalightweight46.2lb/ft2.Panelsarebackedwith1ftthickfoil-backedclass‘0’insulation,andarefinishedpolyesterpowdercoatwhiteRAL9010asstandard.

Modular systemUpto10ftlongasasingleunit174.3BTU/hr/[email protected](mwt-roomtemp)

Modular is particularly suited for use in hospital wards and corridors,schoolhalls,classroomsandoffices.Infactanywherewhere there is a need for high capacity heating with a lightweight aesthetically-pleasingpanel.

FrengerWarmFrengerwarm is a system of custom made, smooth faced aluminiumorsteelpanelsmanufacturedtoanylength/width/shapetosuittheapplication.Panelscanbewallmounted,free-hanging,surfacemountedorrecessedintoasuspendedceilingsystem.Copperpipesarefixedrigidlytotherearofthepanelsviaextrudedaluminiumpipeseatsforoptimumheattransfer.Panelsarebackedwith60mmthickfoil-backedclass‘0’insulation,andarefinishedpolyesterpowdercoatwhiteRAL9010as standard.

RadiantHeating

Page 19: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

19

Modular or perimeter system Can be customised to suit environmentUpto171.2BTU/hr/ft2@99dTFroom

FrengerWarmisparticularlysuitedforuseinschoolgymnasiumsandclassrooms,hospitalwards,corridorsandoffices.Frenger’sbespokemanufacturingapproachenablesustoaccommodatemost applications, including mitred details and column trimming.

PrisonHeatingFrenger’sSecureEnvironment™rangeofantiligatureheatingproductsaredesignedtoprovidereliable,efficientandunobtrusiveheatingwithinSafercell,MHU(MentalHealthUnit)and other secure environments.

ThepurposemadeUKmanufacturedproductrangefeaturesthreecoreproductsthataredesignedtosatisfytheexactingrequirementsofanysecureenvironment:-

PCPFrengerwarmCeilingPanelPNPFrengerwarmCornicePanel.PRFrengerwarmRadiator.

EachProductisdesignedtooperatewithLTHWandhavebeenfully performance tested in accordance with the latest appropriate standards(EN14037/BSEN442).

All purpose designed systems are constructed from reinforced steelpanelingandincludesecurefixingsasstandard.Theanti-vandalconstructionalsotakesaccountofdesigningoutanyligaturepoints.Eachoftheseproductranges(”PCP”,“PNP”and“RR”)havebeenfullydestructiontestedandareconsideredbyNOMS(NationalOffendersManagementService)tobefullycompliantwiththeCustodialPropertySpecification(STD/M/SPEC040)whichcoverstheuseofradiantheatingpanels within Safer Cells.

Considered as NOMS compliantPurposemadesystemscanbetailoredtosuitalmostany

secure environment.DesignedtooperatewithLTHWwatersupplies.Capacitiesinexcessof110.9BTU/hr/[email protected].

EcoSrtipEcoStrip™ is an ideal solution for the industrial heating of larger buildings such as aircraft hangars, sports halls and factories. It maybewallmountedorfree-hangingandisavailableinlengthsfrom15731/64”to472413/32”.Steelpanelspre-fixedto½”steelpipeworkgridstocreatetheradiatingsurface.PanelsareavailableasstandardineitherRAL9010(white)orRAL9002(grey)paintfinish.

Linear productCanbefabricatedonsiteinlengthsupto472413/32”DesignedtooperatewithLTHW,MTHWandHTHWwater

supplies 144.9BTU/hr/[email protected] EcoStripHeatingPanel

PrisonCeilingPanel

CornicePrisonPanel

PrisonPanelRadiator

Page 20: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

20

FrengersAcousticLightingandHeatingRafts,otherwiseknownasMultiServiceRadiantPanels(MSRP’s)consistessentiallyofafreehangingradiantheatingpanelcoupledwithotherservicessuchas:-

Lighting Acoustic Sound absorbing materialsAperturesforsprinklerheadsCompartmenttrunkingforotherelectricalservicesAperturesforPAandVAspeakersLightingControl,PIRandPhotocells

RadiantHeatingThe radiant heating element is the same technology as utilised for Frenger’striedandtestedModulapanels.

The panel is constructed from zinc coated steel which is perforated andfoldedtotheprojectspecificrequirementsbeforebeingpolyesterpowdercoatfinishedtoanyRALcolourasrequired,(RAL9010isstandard).

ThepanelutilisesFrenger’soptimisedextrudedaluminiumheatexchangesandseamlesscoppertubeheatingelements.

Lighting VirtuallyanytypeoflightingsolutioncanbeaccommodatedbyFrenger’sMSRPandalllightingismanufacturedinhouseandbespoketotheprojectsolution.Directonly,indirectonly,combinationof direct and indirect lighting from either the same light source or differentsourcescanbeaccommodated.T5florescentorLEDlightsources, aluminium louvers, micro lens optics, opal acrylic or even extrudedacrylicsforcontinuous/seamlesslightingcanbeaccommodated.

All lighting is designed in house using lighting software design packagesandtheprototypedandphotometeredinFrenger’sinhousePhotometricLaboratoryandIntegrationChamberforL.O.R(LightOutputRatios).FrengerconverttoLumdatfilesandproducelightingcalculationsforthespacerequirementusingRelux/DiluxforcompliancetoCIBSELightingGuidesLG3/7.

Acoustic Sound Absorbing MaterialsTheperforateareasoftheradiantpanelarecoveredwithblacktissue facedinsulatingmaterialwithafoilbackingeffectivelysandwichedinthe middle of two layers of acoustic insulating material, the top layer ofwhichhasblacktissueacousticmaterialfaceupwardsasshowninthe Figure 1.

Frenger’shavetheirowninhousesoundlaboratoryandalsomakeuseofthirdpartyacoustictestingforverifications.

Note:AcousticAbsorptionArea(m)figuresdetailedbelowareperlinearmofMSRP,hencetheabsorptionarea’sshouldbemultipliedbythechosenMSRPlength.DatabaseduponindependenttestingconductedbySRL(SoundResearchLaboratories)Ref.C/21760/R01toBSENISO354:2000.

AcousticLightingandHeatingRafts

HeatingRaftType1

Figure 1

HeatingRaftType2

Page 21: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

LargeProjectExperienceFrengerhasvastexperienceandaproventrackrecordofsuccessfullydeliveringlargecomplexinternationalprojects.

“Frenger designed, manufactured, supplied and installed in excess of 4500 Active Multiservice Chilled Beams for the

prestigious 55 Baker Street project - the UK’s largest MSCB project to date.”

“The extensive refurbishment of 101 New Cavendish Street has been a most

distinguished project incorporating nearly 2 kilometers of Frenger’s Active Multiservice

Chilled Beams over 4-floor levels”

“Frenger successfully designed and supplied over 3,600 linear feet of “Radiant”/

Convective Passive Multiservice Chilled Beams to the new HML HQ building, a subsidiary of Skipton Building Society”

21

Page 22: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

ProjectReferences

22

1 Canberra AvenueAustralia-2013

PassiveChilledBeams

Box Hill HospitalAustralia-2007

Active Chilled Beams

Northwick Park HospitalHarrow,UK-2014

Active Chilled Beams

ANUAustralia-2013

Active Chilled Beams

West Suffolk HouseIpswich,UK-2014

PassiveChilledBeams

SIEC Tonsley HouseAustralia-2013

Active&PassiveChilledBeams

NIA BirminghamBirmingham,UK-2014PassiveChilledBeams

Frimley Park HospitalFrimley,UK-2011

Active Chilled Beams

HDTICoventry,UK-2008

Active Chilled Beams

Holmesglen InstituteAustralia-2010

Active Chilled Beams

IMAS HobartAustralia-2012

PassiveChilledBeams

18-20 Grosvenor StreetLondon,UK-2014

Active Chilled Beams

BBC Grafton HouseMiddlesex,UK-2012

Active Chilled Beams

50 Flinders StreetAdelaide,Australia-2014PassiveChilledBeams

240 Blackfriars RoadLondon,UK-2014

Active Chilled Beams

West Yorkshire PoliceWakefield,UK-2014

PassiveChilledBeams

Great West HouseLondon,UK-2013/14Active Multiservice

Anglia Ruskin UniversityCambridge,UK-2013PassiveMultiservice

Beaufort HouseLondon,UK-2012

PassiveMultiservice

Neo BanksideLondon,UK-2012

Active Multiservice

5 Murray Rose AvenueSydney,Australia-2012PassiveChilledBeams

Exeter UniversityExeter,UK-2012

Active Chilled Beams

Stafford CollegeStafford,UK-2012

Active Chilled Beams

Wyre ForestKidderminster,UK-2012

Active Multiservice

Trinity GrammerTrinidad&Tobago-2012PassiveChilledBeams

Cambridge MetallurgyCambridge,UK-2012PassiveChilledBeams

Tate ModernLondon,UK-2012

PassiveChilledBeams

65 Southwark StreetLondon,UK-2012

Active Multiservice

700 Bourke StreetAustralia-2012

PassiveChilledBeams

Veolia EnvironmentalCannock,UK-2012

PassiveChilledBeams

Page 23: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

23

Common Wealth BankofAustralia,Sydney-2012PassiveChilledBeams

Domino’s Pizza HQMiltonKeynes,UK-2011PassiveMultiservice

Walthamstow StationWalthamstow,UK-2011PassiveChilledBeams

University of BotswanaBotswana-2011

Active Chilled Beams

Royal London HospitalLondon,UK-2011

Active Multiservice

City Centre Tower 8Australia-2011

PassiveChilledBeams

Melbourne UniversityAustralia-2010

Active Chilled Beams

King Saud Bin AbdulSaudiArabia-2011

Active Chilled Beams

Gatwick Search AreaLondon,UK-2011

PassiveChilledBeams

All Saints AcademyCheltenham,UK-2011PassiveChilledBeams

24 Britton StreetLondon,UK-2011

PassiveMultiservice

Eskom, Megawatt ParkSouthAfrica-2011

PassiveChilledBeams

Vodafone InnovationSouthAfrica-2011

PassiveChilledBeams

Wollongong UniversityNSW.Australia-2011

PassiveChilledBeams

World ParkAdelaide,Australia-2011PassiveChilledBeams

Grosvenor HillLondon,UK-2012

PassiveMultiservice

CISCOReading,UK-2012Active Multiservice

Langley PointBirmingham,UK-2012PassiveChilledBeams

Southampton Civic CentreSouthamptonUK-2011

Active Multiservice

Trinidad SchoolTrinidad&Tobago-2011PassiveChilledBeams

Walsall HospitalWalsall,UK-2010

Active Chilled Beams

Macmillan Renton UnitHereford,UK-2010

Active Chilled Beams

Kangan Batman TafeAustralia-2010

Active&PassiveChilledBeams

123 Albert StreetBrisbane,Australia-2010PassiveChilledBeams

HML HeadquartersSkipton,UK-2010

Active Multiservice

500 Collins StreetAustralia-2010

Active Multiservice

Google HeadofficeSydney,Australia-2010PassiveChilledBeams

Royal Hobart HospitalHobart,Tasmania-2010Active Chilled Beams

RMIT 9Australia-2010

Active Chilled Beams

Belconnen PoliceAustralia-2010

PassiveChilledBeams

Page 24: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

24

Five RiversTrinidad-2010

PassiveChilledBeams

Sudima HotelNewZealand-2010

Active Chilled Beams

Liverpool CollegeLiverpool,UK-2010

Active Chilled Beams

1 Shelly StreetSydney,Australia-2009PassiveChilledBeams

Kings CollegeLondon,UK-2009

PassiveChilledBeams

Batman StreetAustralia-2009

PassiveChilledBeams

Edmund BartonCanberra,Australia-2009

Active Chilled Beams

55 Baker StreetLondon,UK-2008

Active Multiservice

Sydney Water HouseAustralia-2008

PassiveChilledBeams

South Australia PoliceAdelaide,Australia-2009PassiveChilledBeams

Kingston Aged CareAustralia-2009

Active Chilled Beams

Monash UniversityAustralia-2009

Active Chilled Beams

Warnambool HospitalAustralia-2009

Active Chilled Beams

Civic OfficesSouthampton,UK-2009Active Chilled Beams

Loxford SchoolLondon,UK-2009

Active Chilled Beams

Cheshire PoliceCheshire,UK-2009

Active Chilled Beams

New Cavendish StreetLondon,UK-2009

Active Multiservice

Knightsbridge HotelLondon,UK-2010

PassiveChilledBeams

Anglia UniversityCambridge,UK-2010PassiveMultiservice

Transport HouseSydney,Australia-2009

Active Multiservice

St Barts HospitalLondon,UK-2009

Active Chilled Beams

New Scotland YardLondon,UK-2010

PassiveChilledBeams

CITCanberra,Australia-2010

Active Multiservice

Kingswood LakesideCannock,UK-2010

PassiveChilledBeams

Meridian CourtEdinburgh,UK-2010

Active Chilled Beams

Good Hope HospitalSutton,UK-2010

Active Chilled Beams

1 Lancaster CircusBirmingham,UK-2010PassiveMultiservice

Telcom SquareNewZealand-2010

PassiveChilledBeams

King Street WharfAustralia-2008

PassiveChilledBeams

Wrexham A&EWrexham,UK-2008

Active Chilled Beams

ACAD Hospitals - StobhillGlasgow,UK-2008

Active Chilled Beams

Coventry UniversityCoventry,UK-2008

Active Chilled Beams

Gatwick TerminalLondon,UK-2008

PassiveChilledBeams

Suffolk County CouncilSuffolk,UK-2008

PassiveChilledBeams

Bidborough HouseLondon,UK-2008

Active Chilled Beams

Page 25: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

25

Hallward LibraryNottingham,UK-2008Active Multiservice

GRI GynaeGlasgow,UK-2008

Active Chilled Beams

Business CentreLiverpool,UK-2008

Active Chilled Beams

Sydney Olympic ParkSydney,Australia-2007PassiveChilledBeams

London CircuitCanberra,Australia-2006PassiveChilledBeams

Saffron HillLondon,UK-2004

Active Multiservice

Woolworth HouseLondon,UK-2003

Active Multiservice

Ealing StudiosLondon,UK-2002

PassiveMultiservice

Royal Sussex HospitalBrighton,UK-2002

Active Chilled Beams

VodafoneLondon,UK-2001

PassiveChilledBeams

Gordon HouseLondon,UK-2001

Active Multiservice

ExperianNottingham,UK-2004PassiveMultiservice

10 Green Coat PlaceLondon,UK-2004

Active Multiservice

Merck Sharp & DohmeLondon,UK-2004

Active Multiservice

The BondAustralia-2003

PassiveChilledBeams

Parramatta JusticeSydney,Australia-2006PassiveChilledBeams

National Audit OfficeLondon,UK-2005

Active Multiservice

500 Collins StreetAustralia-2005

Active Multiservice

City Central TowerAdelaide,Australia-2005PassiveChilledBeams

Edinburgh CouncilEdinburgh,UK-2006PassiveMultiservice

National Farmers UnionWarwickshire,UK-2006PassiveMultiservice

Project VauxhallUK-2006

PassiveChilledBeams

Hills Science ParkMalvern,UK-2006

Active Chilled Beams

Wesley HouseBrisbane,Australia-2008PassiveChilledBeams

Duke StreetLondon,UK-2007

Active Multiservice

University of SydneySydney,Australia-2007PassiveChilledBeams

413 George StreetSydney,Australia-2007PassiveChilledBeams

One East MelbourneVictoria,Australia-2008PassiveChilledBeams

Kings CrossLondon,UK-2008

Active Chilled Beams

Cambridge LibraryCambridge,UK-2008Active Chilled Beams

QMC HospitalNottingham,UK-2008Active Chilled Beams

BT LeavesdenWatford-2002

PassiveChilledBeams

BT NottinghamNottingham-1998

PassiveChilledBeams

Liverpool Int. Business ParkLiverpool,UK-2007

Active Chilled Beams

64 Allara StreetAustralia-2007

PassiveChilledBeams

Page 26: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

Industry AssociationsAlwaysmindfulofitsplacewithintheHEVACindustry,FrengerSystems(tradingasFTFGroupClimate)pridethemselvesonbroadrangeoftradeassociationsandaccreditations.Withaclearservice,productandenvironmentalethosacrosseverythingtheydo,Frengerisfocusedonmeetingandconsistentlysurpassingtheexpectationsofitscustomers.FrengerSystems(tradingasFTFGroupClimate)investheavilyinachieving industry recognised accreditations and as part of ongoing commitment to their customers and continually assess the level of services they provide. Opening up their company to these independent organisations allows them to continually improve our customer service and satisfaction.

AsanengagedmemberoftheHEVACindustry,FrengerSystems(tradingasFTFGroupClimate)areactivelyaskedtoparticipateinindustryspecificdiscussionsandstudies.WiththisinmindFrengerSystems(tradingasFTFGroupClimate)areproudtohaveachievedandbelinkedwiththefollowingassociations:

26

BSI EN ISO 9001:2008Frenger Systems (trading as FTF Group Climate) are registered by BSI for operating a QualityManagementSystemwhichcomplieswiththerequirementsofBSEN9001:2008.

EuroventFrenger Systems (trading as FTF Group Climate) participate in the EC programme for Chilled Beams.Checkongoingvalidityofcertificate:www.eurovent-certification.comorwww.certiflash.com

Chilled Beam and Ceiling AssociationThe Chilled Beam and Ceiling Association has been formed by leading companies within the constructionindustry.TheobjectiveoftheAssociationistopromotetheuseofChilledBeamsand Chilled Ceilings, and encourage best practice in their development and application.

HEVACMemberHEVACistheheatingandventilatingcontractorsassociation.AsaHEVACmemberFrengerSystems(tradingasFTFGroupClimate)aresubjecttoregular,thirdpartyinspectionandassessment to ensure their technical and commercial competence.

BSRIA MemberBSRIA is a consultancy for Building Services Research and Information providing Consulting Engineersandbuildingservicescompaniesandconstructionprofessionalswithmarketresearch, testing and instrumentation services.

Federation of Environment Trade AssociationThe Federation of Environment Trade Association (FETA), of which Frenger Systems (trading asFTFGroupClimate)isamemberof,istherecognisedUKbodywhichrepresentstheinterests of manufacturers, suppliers, installers and contractors within the heat pump, controls,ventilating,refrigeration&airconditioningindustry.

UKTrade&InvestmentFrengerSystems(tradingasFTFGroupClimate)aremembersofboththeUKTI(theformerDepartmentofTradeandIndustry)aswellastheChamberofCommerceforExportDocumentation.

CertifiedCIBSECPDFrengerSystems(tradingasFTFGroupClimate)isaCIBSEapproved“ContinuedProfessionalDevelopment”(CPD)provider.FrengerSystems(tradingasFTFGroupClimate)offers1hourlunchtimeCPDpresentationsregarding“ChilledBeamTechnology”,CPDpresentations (Lunch and Learn) are usually held at Consulting Engineers local practices with lunch provided courtesy of FTF Group Climate. Alternatively Chilled Beam Technology trainingisavailableatFrenger’sUKTechnicalAcademyinadedicatedtrainingtheatrewithfullyoperationalBMSsystemwithvariousdifferentChilledBeamandCeilingsolutionsintegrated.

BookingofaCPDPresentationcanberequestedonFTFGroupClimatehomepage,underthedropdownmenuheaded“Company”,then“CPDBooking”[email protected]

Page 27: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

UKHeadOfficeFrenger System LtdRiverside RoadPrideParkDerbyDE248HY

tel: +44 0 1332 295 678fax:[email protected]

AustralianOfficeFrengerLevel 20Tower 2201SussexStreetSydneyNSW2000Australia

tel: +61 2 9006 1147fax:[email protected]

AmericanOfficeFTF Group Climate1501Broadway,TimesSquare12th FloorNewYorkNY10036United States of America

tel: +00 1 646 571 2151fax:[email protected]

AgentsandDistributorsFrenger has representatives in many countries via businesspartners and local agents.

GlobalOffices

27

Page 28: Company Profile · Contents Company Overview 3 Climate Testing Facility 5 Acoustic Testing Facility 7 Photometric Testing Facilities 8 Bespoke Manufacturing 9 X-Wing® “Radiant

UKHeadOfficeFrenger System LtdRiverside RoadPrideParkDerbyDE248HY

tel: +44 0 1332 295 678fax:[email protected]

AustralianOfficeFrengerLevel 20Tower 2201SussexStreetSydneyNSW2000Australia

tel: +61 2 9006 1147fax:[email protected]

AmericanOfficeFTF Group Climate1501Broadway,TimesSquare12th FloorNewYorkNY10036United States of America

tel: +00 1 646 571 2151fax:[email protected]

Frenger Systems is a wholly owned subsidiary of the FTF Group Ltd.Registered No. 646 6229 20 www.FTFgroup.us

Inaccordancewithourpolicyofcontinuousim

provement,w

ereservetherighttoamendanyspecificationw

ithoutpriornotice.Detailsproducedinthisbrochurem

aynotbecopiedandarenotdrawntoscale.E&O

E.©FTFG

roupClim

ateV2.11