complete medical solution - poct services...medonic m51-d diluent medonic m51-l1 lyse medonic m51-l2...

4
Complete Medical Solution

Upload: others

Post on 01-Mar-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Complete Medical Solution - POCT Services...Medonic M51-D Diluent Medonic M51-L1 Lyse Medonic M51-L2 Lyse 10.4 inch TFT touch screen Tri-angle laser scatter Flow Cytometry (FCM) method

Complete Medical Solution

Page 2: Complete Medical Solution - POCT Services...Medonic M51-D Diluent Medonic M51-L1 Lyse Medonic M51-L2 Lyse 10.4 inch TFT touch screen Tri-angle laser scatter Flow Cytometry (FCM) method
Page 3: Complete Medical Solution - POCT Services...Medonic M51-D Diluent Medonic M51-L1 Lyse Medonic M51-L2 Lyse 10.4 inch TFT touch screen Tri-angle laser scatter Flow Cytometry (FCM) method

Technical specification

Parameters

• RBC, MCV, HCT, RDW-SD*, RDW-CV, HGB, MCH, MCHC

• PLT, MPV, PCT*, PDW*, P-LCC*, P-LCR*

• WBC, LYM#, LYM%, MON#, MON%, NEU#,

NEU%, EOS#, EOS%, BAS#, BAS% AL#*,

AL%*, IG#*, IG%*

*Parameter for research use only

3 RFID locked reagents and one cleaner used for analysis:

Medonic M51-D Diluent

Medonic M51-L1 Lyse

Medonic M51-L2 Lyse

10.4 inch TFT touch screen

Tri-angle laser scatter Flow Cytometry (FCM)

method for WBC 5-part differential analysis

and WBC counting

Impedance method for RBC and PLT counting

Colorimetric method with Cynide free reagent

for Hemoglobin measurement.

Principles

Linearity and Carryover

Parameter

WBC

RBC

HGB

PLT

Linearity Range90-300 x 10 /L

120-8.5 x 10 /L

0-25.0 g/dL90-3000 x 10 /L

Carryover

≤ 0.5%

≤ 0.5%

≤ 0.5%

≤ 1.0%

Printout

External laser printer or inkjet printer, various printout formats and user-defined formats

Interface ports

4 USB ports, 1 LAN port that supportsbidirectional HL7 protocol

364 mm (L) × 431 mm (W) × 498 mm (H)

Dimension

Reagents

Boule Easy Cleaner

Up to 60 samples/h in CBC mode

Up to 45 samples/h CBC + 5-part WBC differential

Throughput

29 parameters:

Samples:

Venous blood, capillary blood, and pre-diluted

Sampling system:

Open tube aspiration

Aspiration volume:

• CBC: 20 μL

• CBC + DIFF: 25 μL

Sample analysis

Data storage capacity

50000 samples

Weight

26.5 kg

Display

CV WBC: ≤ 2.0%CV RBC: ≤ 1.5%CV MCV: ≤ 1.0%CV HGB: ≤ 1.5%

Precision

CV PLT: ≤ 6.0%

Page 4: Complete Medical Solution - POCT Services...Medonic M51-D Diluent Medonic M51-L1 Lyse Medonic M51-L2 Lyse 10.4 inch TFT touch screen Tri-angle laser scatter Flow Cytometry (FCM) method

Marketed By:

POCT SERVICES PVT. LTD.20A(Basement), Najafgarh Road,

Shivaji Marg, New Delhi -110015. INDIAPhone No.: 011 4557 7407

Email id : [email protected]: www.poctservices.com

Toll Free No.: 1800 123 0079

V1.0

. 24042019