  • ZXSDR Series Base StationConfiguration

  • ContentsConfiguration ProcessBackground and PreparationOMCR ConfigurationOMCB ConfigurationLMT ConfigurationData Synchronization

  • Configuration ProcessTransmission network is ok.Configure relevant interface parameters for SDR site in OMCR.FE transmissionE1 transmissionStartConfigure OMCRDataSynchronize data to foregroundEndConfigure OMCBDataConfigure LMTTransmission ParameterCreate the managed element at SDR site in OMCB.Configure the transmission parameters in LMT.Foreground-background link setup conditionsPerform data synchronization after link setupconfiguringEthernet, global port number, IP, SCTP, and OMCBCreating managed element at SDR site. Configuring physical data at SDR site.Configuring radio resource at SDR site.StartConfigure OMCRDataSynchronize data to foregroundEndConfigure OMCBDataSupport remote link setup

  • Configuration ProcessConfiguration Process By Using LMTStartConfigure OMCRDataOnline Uploaddata at backgroundEndCreate manage element in OMCBConfigure LMT DataPerform online upload data after link setup

  • ContentsConfiguration ProcessBackground and PreparationOMCR ConfigurationOMCB ConfigurationLMT ConfigurationData Synchronization

  • SDR Operation and Maintenance NetworkingNetworking While Using Ethernet Bearing at AbisNetworking While Using E1/T1 Bearing at AbisIn the above topology, there is no RPU portion. In fact, the portion of route processing in iBSC is performed by RPU.

  • Networking Instance*In the instance, X=2, indicating GSM site id is 2.

  • ContentsConfiguration ProcessBackground and PreparationOMCR ConfigurationOMCB ConfigurationLMT ConfigurationData Synchronization

  • Configuring BSC FunctionOMCB IPIPABIS and OMCB channel IPFor E1 transmission, both addresses are same. For FE transmission, two addresses are different if using VLAN, and you shall set two virtual addresses. If you do not use VLAN, both addresses are same too.

  • Configuring Abis Interface Board (E1 Abis) DTB board PCM informationCreate the EUIP boardwhile iBSC connects SDR site by using IP OVER E1 mode, select Multi frame.12

  • Configuring Abis Interface Board (FE Abis)Configure IPBB interface board*While using FE mode at Abis, it is not required to configure DTB board and EUIP board for the resource shelf at Abis , and you shall configure IPBB interface board for the resource shelf at Abis

  • Configuring OMCB Interface BoardConfigure IPBB interface boardThe IPBBs for OMCB access and SDR access can use the different network ports on a board, but these two network ports shall be configured in different network segments.

  • Configuring IP Abis Interface (Virtual Address) Create RPU board function type Set the parameters for IP ABIS12

  • Configuring Access Interface for OMCB Set the parameters for IPBB Create IPBB board function type12

  • Configuring Access Interface for SDR (E1 Abis)Create IP Over E1 Configuration Create EUIP Interface for E1 AccessCreate PPP Configuration123

  • Configuring Access Interface for SDR (FE Abis) Set the parameters for IPBB2 Create IPBB board function type1

  • Configuring Logic SDR SiteConfigure a Logic Site Configure a Rack12You can only create B8200 while configuring SDR site.

  • Configuring Logic SDR Site Configure TRX Configure a Cell12

  • ContentsConfiguration ProcessBackground and PreparationOMCR ConfigurationOMCB ConfigurationLMT ConfigurationData Synchronization

  • Modifying Server ProfilesModify deploy-030womcb.properties with omc UserModify FTP Related Profile with omc Userthe default port number is 21

  • Configuring Basic SDR DataCreate SDR Managed ElementCreate Base Station Config SetKeeping consistent with the GSM base station id

  • Configuring Base Station Equipment ResourceCreate base station equipment resource management Configure physical rack BBU Configure physical rack RRU123Keeping consistent with the GSM base station id

  • Configuring Base Station Equipment ResourceConfigure the antennaConfigure the rack topology45

  • Configuring Transmission Resource (E1 Abis) Configure the E1/T1 cableConfigure the HDLC Configure PPP configurationFor the SDR site connected to BSC by star link, select BSC; for the SDR site connected to parent SDR site by chain link, select BTS123

  • Configuring Transmission Resource (E1 Abis)Global portIP propertySCTP OMCB connection4567For E1 transmission, it is not required. After link setup between foreground and background, automatically set it.IP AbisRPUthe IP address of OMCBchannel

  • Configuring Transmission Resource (FE Abis)Configure the EthernetConfigure the global port Configure the IP property123Select IPbone for direct station and select BTS for cascading station

  • Configuring Transmission Resource (FE Abis)SCTPOMCB connection45*While using FE at Abis, you need use LMT to configure transmission parameters (consistent with the configuration data on OMCB). After link setup between foreground and background, you can synchronize the OMCB configuration data with foreground.

  • Configuring Radio ResourceCreate base station radio resource management Configure the central frequency point12

  • Configuring Radio Resource Configure the sector parameters Configure the GSM RU parametersConfigure the GSM carrier354

  • ContentsConfiguration ProcessBackground and PreparationOMCR ConfigurationOMCB ConfigurationSDR LMT IntroductionData Synchronization

  • OverviewEOMS: The special software version of EOMS and EFMS can be loaded or activated at the site by using LoadTool.EOMS_EFMS: the copy version of operation, maintenance, and fault management.JRE: the installer of Java running environment.LMTSetup.exe: DMS and PMS installer file.readme.txt: the readme file for installer.

    Local LMT configuration is same as the configuration done by OMCB. On field, you also can use all data configured by LMT,create the SDR managed element for this site on OMCB, to set up a link between foreground and background, so the SDR site data is reversely constructed at background.LMT Directory

  • LMT Connects SDRCC ETH1If there are CC boards on slot 1 and 2, you shall view the MS indicator after powering on.

    *X is the environment ID, used to differentiate the differentSDR sites within a network. The default environment ID is 254.Slot No.1 (CC-1) IP: 192.X.1.16Slot No.2 (CC-2) IP: 192.X.2.16

  • The procedure of configuring the base station*Configure it on FE transmission for link setup between foreground and background.

  • ContentsConfiguration ProcessBackground and PreparationOMCR ConfigurationOMCB ConfigurationSDR LMT IntroductionData Synchronization

  • Data SynchronizationAfter link setup at foreground and background, the small green icon in front of the site managed element becomes connected state

  • Online Uploading DataIf all configuration actions have been done by LMT at SDR site and the network transmission is proper, the link is set up between foreground and background. After link setup, you can upload the existing data at foreground into background.