compliance listing guide

8
COMPLIANCE LISTING GUIDE XR150INT/XR550INT SERIES INTERNATIONAL CONTROL PANEL

Upload: others

Post on 13-May-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: COMPLIANCE LISTING GUIDE

COMPLIANCE LISTING GUIDE

XR150INT/XR550INT SERIES INTERNATIONAL CONTROL PANEL

Page 2: COMPLIANCE LISTING GUIDE

MODEL XR150INT/XR550INT SERIESINTERNATIONAL COMPLIANCE GUIDE

© 2015 Digital Monitoring Products, Inc.Information furnished by DMP is believed to be accurate and reliable.

This information is subject to change without notice. This information is subject to change without notice.

Page 3: COMPLIANCE LISTING GUIDE

XR150/XR550 Series International Listing Guide Digital Monitoring Productsiii

TABLE OF CONTENTS

Before you BeginWiring Diagrams

1.1 SpecificandNon-specificWiredInterconnections .............................................2

Intrusion and Hold-up Systems EN 50131-12.1 Security Grade ...............................................................................................32.2 Environmental Class .......................................................................................32.3 Power Supply ................................................................................................3

Control and Indicating Equipment EN 50131-33.1 Operating Temperature and Humidity Range ....................................................33.2 WeightsandDimensions ................................................................................33.3 XR150INT/XR550INTSeriesStatusListDisplay ................................................33.4 734 Programming ..........................................................................................43.5 Entry/ExitDelay ............................................................................................43.6 Transmit Delay ..............................................................................................43.7 Bell Cutoff .....................................................................................................43.8 Auto Arming the System ................................................................................43.9 Fault and Tamper Alerts .................................................................................43.10 ZoneExpander ..............................................................................................43.11 Swinger Bypass .............................................................................................43.14 DisarmedShort/Open ....................................................................................43.15 Masking ........................................................................................................43.16 UserCodesandPINCodes .............................................................................43.17 Keypad Display Time Out ...............................................................................43.18 EventLog .....................................................................................................43.19 Discharge/Recharge .......................................................................................43.20 Over Voltage Protection .................................................................................43.21 Closing Code .................................................................................................43.22 NotificationOutputSignals .............................................................................53.23 Operation Mode .............................................................................................53.24 Dual Path Operation.......................................................................................53.25 Control Panel Unav ailability ...........................................................................5

Page 4: COMPLIANCE LISTING GUIDE

XR150/XR550 Series International Listing Guide Digital Monitoring Products1

PROGRAMMING OPTIONS

Before you BeginThis guide provides compliance information for the DMP XR150INT/XR550INT Series International Control Panels. After this Introduction, the remaining sections describe the functions along with the available options. Before starting, we recommend that you read through the contents of this guide. The information contained here allows you to quickly learn the operation, functionality, and programming options of the panel to meet specific applications.This guide covers all the requirements for the following panels:

• XR150INT Series• XR550INT Series

Page 5: COMPLIANCE LISTING GUIDE

Digital Monitoring Products XR150/XR550 Series International Listing Guide2

WIRING DIAGRAMS

Wiring Diagrams1.1 SpecificandNon-specificWiredInterconnectionsThe following pages show examples for wiring requirements.

AC

1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 199 20 21 22 23 24 25 26 27 28

+B BELLGND SMK GNDRED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9+ Z9– Z10+Z10–AC –B GND GND GNDGND

Auxiliary Power Total current combined from terminals 7, 11, 25, 27, XBUS and LX500-LX900 1.5 Amp Max 13.8 VDC to 10.2 VDC

LX80

0

LX90

0

J4Tamper

K6 K7

Output 1 Output 2

J3Phone Line

BatteryStart

J8

J16Reset

Out

1O

ut2Outputs 3-6

J113 4 5 6

J2

OVC

XR550INT SeriesInternational Panel

LX50

0

LX70

0

XBUS

J13

J14 J9 J15 J19J17

J24

Form C Relays (J2)Output Color Code–Model 431 HarnessOutput 2 N/O Orange/WhiteOutput 2 Com White/GrayOutput 2 N/C Violet/WhiteOutput 1 N/O OrangeOutput 1 Com GrayOutput 1 N/C Violet

Annunciator Outputs (J11)Output Color CodeOutput 3 RedOutput 4 YellowOutput 5 GreenOutput 6 Black

ss

J12 75VA

50VA

Listed Resistors1.0k Ohm - DMP Model 3113.3k Ohm - DMP Model 30910K Ohm - DMP Model 308

LX60

0

Tamper

16 to 18 gauge wireMaximum AC Wire distance with 16 gauge wire: 70 feetwith 18 gauge wire: 40 feet RED

BLACK

Cold Water Pipe Earth Ground

Bell

3.3k Ohm Resistor DMP Model 309

3.3k Ohm Resistor DMP Model 309

s = Supervised Circuit

Zone 9

Zone10

22 g

auge

min

imum

22 g

auge

min

imum

22 g

auge

min

imum

22 g

auge

min

imum

RED

YELL

OW

GREE

N

BLAC

K

Zone Expander Models 714-8INT,

714-16INT20mA @ 12 VDC

REDYELLOWGREENBLACK

sDual1k

Ohm

Zone Expander (up to 8 zones) Model 712-8INT19mA @ 12 VDC

1k Ohm

Earth Ground

s s s s

s s s

s

sss

s

s

¼"

AC Wiring must be in conduit and exit out the left side of the enclosure. Wiring on terminals 5 through 22 must exit right and maintain 1/4" separation from the AC and battery positive wiring.

Dual1k

Ohm

Dual1k

Ohm

Dual1k

Ohm

Dual1k

Ohm

Dual1k

Ohm

Dual1k

Ohm

Dual1k

Ohm

s s s s s s s ss s s s s s s s

Dual1k

Ohm

s s

Dual1k

Ohm

s s

Dual1k

Ohm

s s

Dual1k

Ohm

s s

s

Model 324INT 230V 100VA

CAUTION: DO NOT USE LOOPED WIRE UNDER TERMINALS. BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS.

WARNING: Incorrect

connections may cause

damage to the unit.

Bell cutoff time range is 2 to 15 minutes, non-coded.

Bell 12 VDCDefault cutoff time 15 min.Minimum cutoff time 2 min.1.5 Amp Max

Conduit

INPUT OUTPUT

GRO

UN

D

Page 6: COMPLIANCE LISTING GUIDE

XR150/XR550 Series International Listing Guide Digital Monitoring Products3

PROGRAMMING OPTIONS

Intrusion and Hold-up Systems EN 50131-1

2.1 Security GradeThe Model XR150INT/XR550INT Series International provides a Security Grade 3 fulfilling Options A, B, or C.

2.2 Environmental ClassThe Model XR150INT/XR550INT Series International provides Environmental Class II.

2.3 Power SupplyThe Model XR150INT/XR550INT Series International employs a Type A power supply.

Control and Indicating Equipment EN 50131-3

3.1 Operating Temperature and Humidity RangeThe XR150INT/XR550INT Series International is suitable for temperatures ranging from 0°C to 49°C and a relative humidity of 80%.

3.2 Weights and DimensionsThe XR150INT/XR550INT PCB Series International weighs 1.7 kg and is 26 cm wide by 14 cm high.

3.3 XR150INT/XR550INT Series Status List Display

Priority Category Description Latches Display

1 Fire Zone Alarms FI and FV zone alarms Y2 Emergency Alarms EM zone alarms Y3 Fire troubles and Supervisory

alarms and troublesFI, FV and EM troubles SV alarms and troubles

Y

4 Burglary Zone Alarms NT, DY, EX and AR Zone Alarms N5 System Messages Walk Test

Transmitter MissingTransmitter Low BatteryWireless JammingWireless Keypad Missing, Tamper, AC Power, Low Battery, Wireless Keypad Trouble, Z-Wave Lock Low BatteryAny other System Monitor Troubles

N

6 Late to Close Message System has not armed as Scheduled N7 All other Zone Messages Key Fob Alarm, Low Battery, Missing, Trouble

Output Alarm, Low Battery, Missing, TroubleDoor ProppedZone MonitorDay Zone AlertAlarms on PN, A1 and A2

N

8 Armed or Ready Status Status of the Panel N9 Day and Time Current Date and Time N10 Today’s Current Weather Today’s Weather N11 Tomorrow’s Weather Tomorrow’s Weather N14 Keypad Bus Device Message Device Missing

Device TamperN

Page 7: COMPLIANCE LISTING GUIDE

Digital Monitoring Products XR150/XR550 Series International Listing Guide4

OPERATION

3.4 734 ProgrammingAfter initial installation, changes to 734/734N programming must be made through the device setup menu in panel programming.

3.5 Entry/Exit DelayIn System Options, set Entry Delay 30 - 45 seconds. In Area Information, set Exit Delay to 30 - 45 seconds.

3.6 Transmit DelayIn Communications, Transmit Delay must be set the same as Entry Delay in System Options.

3.7 Bell CutoffIn Bell Options, Bell Cutoff must be set to 2 - 15 minutes.

3.8 Auto Arming the SystemIn Area Information, Closing Check must be ON when using Auto Arm. When arming, Closing Time! is displayed for 10 minutes and the keypad sounds. Bad zones are processed according to the Bad Zones programming in Area Information. Other troubles are automatically overridden.

3.9 Fault and Tamper AlertsWhen a fault or tamper alert is listed in the status list, only the Service User can arm the system until the fault or tamper is corrected.

3.10 Zone ExpanderWhen using a zone expander module, one zone of the module must be used as tamper supervision.

3.11 Swinger BypassIn System Options, SWGRBYPS TRIPS: must be set to 3 or higher.

3.14 Disarmed Short/OpenIn Zone Programming, the Alarm Action message sent to Central Station for Disarm Short and Disarm Open must be set to T for Trouble Alert.

3.15 MaskingConnect a zone to the masking contacts of a device. Name the zone in Zone Programming “X Detector Masking”, where X is the name of the detector zone and for Alarm Action, set the Transmit Message to T (Trouble) for both Disarmed and Armed actions.

3.16 User Codes and PIN CodesUser Codes and PIN Codes must be at least 5-digits (0 - 9) for a total of 100,000 possible combinations.

3.17 Keypad Display Time OutA valid User Code is required to be entered to display the Status List. The display will time out in 60 seconds with no key presses. A valid User Code will be required to be entered again to view list.

3.18 Event LogEvents are stored in non volatile memory with greater than 100 year data retention. Manufacturer part number SST39VF3202B.

3.19 Discharge/RechargeThe XR150INT/XR550INT Series International battery charging circuit float charges at 13.8 Vdc at a maximum current of 1.5 Amps using a 100VA transformer, Listed below are the various battery voltage level conditions:

Battery Trouble: Below 11.2 Vdc Battery Cutoff: Below 10.2 Vdc Battery Restored: Above 12.6 Vdc

The panel disconnects the battery any time the battery voltage drops below 10.2 Vdc. This prevents battery deep discharge damage. The XR150INT/XR550INT will charge a maximum of 45Ah batteries to 80% in 24 hours.

3.20 Over Voltage ProtectionOutput circuitry is designed to limit voltage to 15V.

3.21 Closing CodeIn System Options, set Closing Code to YES.

Page 8: COMPLIANCE LISTING GUIDE

80 0 - 64 1 - 4282 I N T R U S I O N • F I R E • A C C E S S • N E T W O R K S

www.dmp . com 2500 No r t h Pa r t ne r s h i p Bou l e va rdDesigned, Engineered and

Assembled in U.S.A. Sp r i n gfie l d , M i s s ou r i 6 5803 - 8877

LT-1

330I

NT

1.01

© 2

016

Dig

ital

Mon

itor

ing

Prod

ucts

, In

c.

1620

4

Documentation Power Supply Type A Security Grade 3 Environmental Class II EN 50131-1 Notification Requirements Grade 3 Options A,B, or C Operating Temperature 0°C - 49°C 32°F - 120°F Relative Humidity 80% Weight 1.7 kg) Dimensions 26W x 14H cm Max Ripple Voltage 50mV

InternationalCertificationsIntertek (ETL)EN 50130-4 EMC Product Family Standard:

Immunity Requirements for Components of Fire, Intruder and Social Alarm Systems

EN 50130-5 Environmental StandardsEN 50131-1:2006+A1 Intrusion and hold-up systems EN 50131-3:2009 Control and Indicating Equipment EN 50131-5 Interconnections Equipment using

Radio Frequency techniquesEN 50131-6:2008 Power SuppliesEN 50133-1:1997 Access Control Systems EN 50136-1 Alarm Transmission Systems and

EquipmentEN 50136-2:2013 Supervised Premises TransceiverEN 50136-3 Receiving Centre TransceiverEN 50131-6 Power Supplies

EN 61000-3-2 Limits - Limits for Harmonic Current Emissions (Equip.Input Current up to and Including 16 A per Phase) Includes A1 & A2 July 1, 2009

EN 61000-3-3 Limitation of Voltage Fluctuations & Flicker in Low-Voltage Supply Systems for Equip. with Rated Current Less Than or Equal to 16 A per Phase & Not Subject to Conditional Connection

EN 61000-6-4 Generic Standards - Emission Standard for Industrial Environments

Export Control The XR550INT with encryption uses AES

encryption and any export beyond the United States must be in accordance with Export Administration Regulations.

3.22 NotificationOutputSignalsProvides Hold-up, Tamper, and Intrusion notifications.

3.23 Operation ModeStores and forwards all messages to SCS-VR or SCS-1R.

3.24 Dual Path OperationCommunication takes place on the primary path with backup paths being used only when the primary path fails or when the backup path is being used to send duplicate messages.

3.25 Control Panel UnavailabilityThe control panel is considered unavailable when the system message 16 panel NOT RESPONDING is generated by the central station receiver.