comprehensive asbestos and lead-based paint xrf …
TRANSCRIPT
COMPREHENSIVE ASBESTOS AND LEAD-BASED PAINT XRF SURVEY REPORT
For:
LA HABRA HIGH SCHOOL AQUATICS FACILITY
801 HIGHLANDER AVENUE, LA HABRA CALIFORNIA, 90631
Presented To:
FULLERTON JOINT UNION HIGH SCHOOL DISTRICT 1051 WEST BASTANCHURY ROAD FULLERTON, CALIFORNIA 92833
Presented By:
1322 Bell Avenue, Suite 1N Tustin, California 92780 Phone: 714-247-0024 Fax: 714-247-0025
Bainbridge Project # 20027913.12
March 11, 2020
March 11, 2020 Ms. Kate Kwon Assistant Construction Projects Manager Fullerton Joint Union High School District 1051 West Bastanchury Road Fullerton, California 92833 RE: Phase 1 – Comprehensive Asbestos and Lead-Based Paint XRF Survey Report for
the La Habra High School – Aquatics Facility located at 801 Highlander Avenue, La Habra California, 90631
Dear Ms. Kwon: At the request of the Fullerton Joint Union High School District (FJUHSD), Bainbridge Environmental Consultants, Inc. (Bainbridge) conducted a comprehensive asbestos and lead-based paint XRF survey at La Habra High School – Aquatics Facility for the upcoming/scheduled Pool Alteration Project located at the above-mentioned address. This document has been prepared for the sole use of Fullerton Joint Union High School District, their authorized agents, and any State, or local agencies involved in this project. No other party should rely on the information contained herein without prior written consent of Bainbridge. Thank you for the opportunity to be of service. Please do not hesitate to call us with any questions. We look forward to assisting you in the future. Sincerely, Bainbridge Environmental Consultants, Inc.
Karlin Cisco Director of Operations CAC # 16-5626 CDPH LRC I/A #00003694 Bainbridge Project #: 20027913.12 KC/bb
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 3
TABLE OF CONTENTS
Section
1.0 Asbestos Survey/Investigation 1.1 Asbestos Findings 1.2 Asbestos Recommendations 1.3 Disclaimer And Limitations For Asbestos Related Projects
2.0 Lead-Based Paint XRF Testing of Painted Surfaces 2.1 Lead-based Paint XRF Findings 2.2 Lead-based Paint Recommendations 2.3 Disclaimer And Limitations For Lead-Based Paint and Components
Appendices
A. ASBESTOS FIELD DATA AND LABORATORY RESULTS B. LEAD-BASED PAINT XRF FIELD DATA AND ANALYTICAL RESULTS C. ASBESTOS AND LEAD-BASED PAINT INSPECTOR’S STATE CERTIFICATIONS D. ASBESTOS AND LEAD-BASED PAINT XRF SAMPLE LOCATION DRAWINGS E. SURVEY PHOTOGRAPHS
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 4
1.0 Asbestos Survey/Investigation
Marco Silva, DOSH Certified Site Surveillance Technician (CSST) #19-6694, under the direction of Karlin Cisco, DOSH Certified Asbestos Consultant (CAC) #16-5626, of Bainbridge, performed the comprehensive survey activities and collected the suspect asbestos-containing building material bulk samples for laboratory analysis at La Habra High School – Aquatics Facility located at 801 Highlander Avenue, La Habra, California 90631. The survey was performed on the dates of March 3 & 4, 2020, in addition to a client acceptance walk conducted on March 6, 2020. Our comprehensive asbestos survey consisted of bulk sampling and collection of suspect asbestos-containing materials scheduled to be impacted during the upcoming/scheduled pool alteration project. This report reviews and summarizes the findings outlined in the attached asbestos bulk sample log and laboratory analysis report. During this inspection, several criteria including bulk sampling were used to properly assess areas investigated. Visual and tactile assessments of suspect asbestos-containing building materials provided the basis for these criteria and allowed the inspector to group the materials into homogenous areas. Bainbridge conducted the asbestos bulk sampling of the subject Aquatics Facility in compliance with the following Federal, State, and Local regulations: Code of Federal Regulations (CFR): • 40 CFR Part 763 - Asbestos Containing Materials In Schools. • 29 CFR 1910.1001 - Occupational Exposure to Asbestos, Tremolite, Anthophyllite/Actinolite • 29 CFR 1910.1101 - Asbestos • 29 CFR 1910.1200 - Hazard Communication • 29 CFR 1910.20 - Access to Employee Exposure and Medical Records • 29 CFR 1910.132 - General Requirements – Personal Protective Equipment • 29 CFR 1910.133 - Eye and Face Protection • 29 CFR 1910.134 - Respiratory Protection • 29 CFR 1910.145 - Specifications for Accident Prevention, Signs and Tags • 29 CFR 1910.1101 - Asbestos Standard for construction Industry • 40 CFR 61 - Sub-part A General Conditions • 40 CFR 61 - Sub-part M National Emission Standards for Asbestos • 40 CFR 61.152 - Standard for Waste Disposal for Manufacturing, Demolition, Renovation,
Spraying and Fabrication Operations. U.S. Environmental Protection Agency (EPA): • Publication No. 560/5-85-024 - Guidance for Controlling Asbestos-Containing Materials in
Buildings.
Title 8 California Code of Regulations (CCR): • Section 1529 - Asbestos • Section 5208 - General Industry Safety Orders South Coast Air Quality Management (SCAQMD): • Rule 1403- Asbestos Emissions from Demolition/Renovation Activities.
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 5
1.1 Asbestos Findings A total of sixty (60) bulk samples were collected for laboratory analysis. Some of these samples were separated [by the laboratory] by individual layers to determine a more accurate analysis. Therefore, the total number of the samples analyzed was seventy-one (71). All samples collected were submitted under the chain of custody protocol to LA Testing Laboratories Inc., located in Huntington Beach, California 92649. LA Testing is certified with the NVLAP registration (code: 101384-0) and approved for asbestos bulk sample analysis in the State of California. The sample analysis was performed by EPA Polarized Light Microscopy (PLM) coupled with dispersion staining, method 600/R-93/116, July 1993. All PLM analyses are derived from a calibrated visual estimate unless otherwise noted. The following materials were inaccessible for testing and determined to be presumed asbestos-containing materials (PACM) at >1%: Aquatics Facility: Presumed Asbestos-Containing Materials
In the event that other suspect building materials (not included in this survey report) are discovered and have the potential to be impacted or disturbed during construction, renovation and/or demolition activities; those suspect building materials will be considered asbestos-containing materials until a State Certified, Asbestos Consultant is retained to determine asbestos content of those materials. Federal regulations define asbestos-containing material (ACM) as any material that contains more than one percent (>1%) asbestos. State Cal/OSHA-California Labor Code, Section 6501.8 defines “asbestos containing construction material (ACCM)” as any manufactured construction material that contains more than one tenth of one percent (>0.1%) asbestos by weight.
Sample No.
Sample Location
Sample Description Color Material
Condition
Friable Non-
Friable
Material Location
Approx. Quantity
Laboratory Results
PACM- 61. Inside Pool Pool Basin
Plaster White Good Non-Friable
Pool Basin throughout
Pool
1,000 Sq. Ft.
PACM/ >1% ACM
(Inaccessible for Testing)
PACM – 62. Pool Trim Concrete
Coping Multi Good Non-Friable
Concrete Coping
around Pool Trim
250 Sq. Ft.
PACM/ >1% ACM
(Inaccessible for Testing)
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 6
1.2 Asbestos Recommendations Based on the available information gathered during the performance of this survey and its conclusions, Bainbridge recommends the following:
• Identified presumed and/or asbestos-containing materials must be removed prior to the scheduled demolition activities in adherence with South Coast Air Quality Management District (SCAQMD) regulations (Rule 1403).
• Bainbridge recommends the preparation of project specifications for the removal of
identified presumed and/or asbestos-containing materials and/or Cal/OSHA regulated asbestos-containing construction materials (samples greater than .1% asbestos), as necessary. A State of California Certified Asbestos Consultant should be retained to properly document, inspect, and monitor the removal of any identified and/or assumed asbestos-containing materials. This is to ensure adherence to applicable State and Federal regulations and for the safety of building occupants in the vicinity of the abatement areas.
• Bainbridge recommends that a Cal/OSHA registered and State licensed abatement
contracting company perform the abatement of the above-mentioned presumed and/or asbestos-containing materials. Any asbestos related work must be conducted in accordance with all applicable Federal, State, and local regulations. Firms performing the asbestos-related work must follow proper engineering practices and must use state-of-the-art techniques as outlined in Bainbridge’s Asbestos Abatement Project Specifications Section 02080 – Asbestos Abatement.
1.3 Disclaimer and Limitations for Asbestos Related Projects This document is prepared for the sole use of the Fullerton Joint Union High School District and its authorized representatives and any agencies directly involved in this project. No other party should rely on the information contained herein without prior written consent of Bainbridge. The information in this report or portions thereof may be required to be included in notifications to employees, contractors or other visitors to the building. The Fullerton Joint Union High School District or its agents shall not use this report as a specification or work plan for any of the work suggested or recommended in the report. This report is based upon conditions and practices observed at the property and information made available to Bainbridge. This report does not identify all hazards or unsafe practices, nor does it indicate that other hazards or unsafe practices exist at the premises. The conclusions and summary presented in this report are based on a review of pertinent regulations, and guidelines or requirements commonly followed by industry standards, data collected during the site inspection, and information provided by the Fullerton Joint Union High School District, their clients, agents, and representatives. The work has been conducted in an objective and unbiased manner and in accordance with generally accepted professional practice for this type of work. Bainbridge believes the data and analysis to be accurate and relevant but cannot accept responsibility for the accuracy or completeness of available documentation or possible withholding of information by other parties. Any observations of asbestos containing materials represent the conditions at the specified locations and times of the site inspection survey only.
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 7
2.0 Lead-Based Paint XRF Testing of Painted Surfaces Marco Silva, CDPH Certified Lead-Related Construction, Sampling Technician, under the direction of Karlin Cisco, CDPH Certified Lead-Related Construction, Inspector Assessor of Bainbridge, performed the comprehensive survey activities and collected the lead-based paint XRF readings at La Habra High School - Aquatics Facility located at 801 Highlander Avenue, La Habra, California 90631. The purpose of the survey was to identify any suspect lead-containing building materials that are scheduled to be impacted or disturbed during an upcoming/scheduled pool alteration project. The survey was performed on the date of March 4, 2020 and consisted of collection of XRF readings of suspect lead-based painted building materials in the Aquatics Facility. This report reviews and summarizes the findings outlined in the attached lead-based paint XRF sampling log with analytical results. Bainbridge conducted the lead-based paint survey of the subject Aquatics Facility in compliance with the following Federal, State, and Local regulations: • 24 CFR Part 35.80-35.98 and 35.3120(b) – U.S. Department of Housing and Urban
Development (HUD) • Toxic Substances Control Act (TOSCA) Section 406 • 40 CFR 745.103 – Environmental Protection Agency (EPA) • Title 17 Section 35000 – Code of California Regulations • Cal/OSHA Title 8 Section 1532.1 – California Occupational Safety and Health Administration • Cal/OSHA Title 8 Section 5194 – California Occupational Safety and Health Administration Currently, the State of California, the U.S. Department of Housing and Urban Development (HUD), and the Environmental Protection Agency (EPA) define lead-based paint as paint or other surface coating with lead content equal to or greater than 1.0 milligrams per square centimeter (mg/cm2), 0.5% by weight, and/or 5,000 parts per million (ppm) lead on the surface area. XRF Paint Readings: XRF measurements were collected. Bainbridge conducted this comprehensive survey using a Viken PB200i Analyzer, X-ray Fluorescence (XRF) detector. All survey activities and XRF measurements were performed in accordance with the United States Department of Housing and Urban Development’s guidance document, entitled “Guidelines for the Evaluation and Control of Lead-based Paint Hazards in Housing: Chapter 7 Lead-based paint inspection”. The XRF Lead Sampling Logs are provided as an attachment to this survey/inspection report. These logs tabulate each individual test, sample taken throughout the subject areas and describes the test location, the component to which the paint is applied, condition, color and lead content in milligrams per square centimeter and the result. In the event that other materials are found to be similar or homogenous to the materials sampled, those similar or homogenous materials will be considered lead-containing materials. Prior to bid, contractor is responsible for field verification of those materials, their quantities and measurements.
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 8
2.1 Lead-Based Paint XRF Findings XRF Testing: A total of sixty (60) XRF readings were collected. The field data and results of the XRF testing are included in Appendix B of this report. As a result of lead-based paint XRF testing, the following materials were determined to contain lead-based paint: Aquatics Facility: Lead-Based Paint XL No Side Bldg Room Source Substrate Color
Results Positive Negative
Approx. Quantity mg/cm2
30 A Aquatic Facility
Pool Area Pool Trim Concrete Red 2.1 Positive 7
Sq. Ft.
31 C Aquatic Facility
Pool Area Pool Trim Concrete Red 1.4 Positive See
XL No 30
35 B Aquatic Facility
Pool Area
Pool Interior
Wall Lining Concrete White 1.0 Positive 5,929
Sq. Ft.
36 B Aquatic Facility
Pool Area
Pool Interior
Wall Lining Concrete White 9.0 Positive See
XL No 35
37 C Aquatic Facility
Pool Area
Pool Interior
Wall Lining Concrete White 3.8 Positive See
XL No 35
38 D Aquatic Facility
Pool Area
Pool Interior
Wall Lining Concrete White 8.8 Positive See
XL No 35
39 D Aquatic Facility
Pool Area
Pool Interior
Wall Lining Concrete White 8.7 Positive See
XL No 35
40 A Aquatic Facility
Pool Area
Pool Interior
Wall Lining Concrete White 8.1 Positive See
XL No 35
In the event that other suspect building materials (not included in this survey report) are discovered and have the potential to be impacted or disturbed during demolition activities; those suspect building materials will be considered lead-containing materials until a State Certified, Inspector/Assessor is retained to determine lead content of those materials.
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 9
2.2 Lead-Based Paint Recommendations Based on the available information gathered during the performance of this survey and its conclusions, Bainbridge recommends the following:
• The removal of the identified lead-based paint components from the subject aquatics facility prior to the demolition activities. Bainbridge recommends the utilization of a State licensed lead abatement contracting company to remove, transport and dispose of the identified lead-containing waste in according to applicable Federal and State regulations.
• The Occupational Safety and Health Administration (OSHA) promulgated legislation (29 CFR 1926.62 and 8 CCR1532.1) entitled "Lead Exposure in Construction Industry", requires that any job that may potentially expose workers to any concentration of lead (i.e., >0.01 mg/cm2) be monitored by the employer to determine workers eight-hour time weighted average (TWA) exposure to lead.
2.3 Disclaimer and Limitations for Lead-Based Paint and Components This document is prepared for the sole use of Fullerton Joint Union High School District and its authorized representatives and any agencies directly involved in this project. No other party should rely on the information contained herein without prior written consent of Bainbridge. The information in this report or portions thereof may be required to be included in notifications to employees, contractors or other visitors to the aquatics facility. Fullerton Joint Union High School District or its agents shall not use this report as a project specification or work plan for any of the work suggested or recommended in the report. This report is based upon conditions and practices observed at the property and information made available to Bainbridge. This report does not identify all hazards or unsafe practices, nor does it indicate that other hazards or unsafe practices exist at the premises. This inspection and assessment was planned, developed, and patterned after HUD Guidelines Chapter 7 Lead-based paint inspection. Bainbridge utilized state-of-the-art practices and techniques in accordance with regulatory standards while performing this inspection. Bainbridge’s evaluation of the relative risk of exposure to lead identified during this inspection is based on conditions observed at the time of the inspection. Bainbridge cannot be responsible for changing conditions that may alter the relative exposure risk or for future changes in accepted methodology. The conclusions and summary presented in this report are based on a review of pertinent regulations, and guidelines or requirements commonly followed by industry standards, data collected during the site inspection, and information provided by the District, their clients, agents, and representatives The work has been conducted in an objective and unbiased manner and in accordance with generally accepted professional practice for this type of work. Bainbridge believes the data and analysis to be accurate and relevant but cannot accept responsibility for the accuracy or completeness of available documentation or possible withholding of information by other parties.
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 10
Any observations of lead-based paint and lead containing materials represent the conditions at the specified locations and times of the site inspection survey only. The selection of sample areas was limited to accessible areas of the subject aquatics facility.
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 11
APPENDIX A
ASBESTOS FIELD DATA AND LABORATORY RESULTS
1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 1 of 5 Fax (714) 247-0025
Sample No.
Sample Location
Sample Description Color Material
Condition Friable
Non-Friable Material Location
Approx. Quantity
Laboratory Results
1. Co-Gen 260 - East Plaster White Good Non-Friable Plaster throughout Co-Gen 260
500 Sq. Ft.
None Detected
2. Co-Gen 260 - South Plaster White Good Non-Friable See Above Included Above
None Detected
3. Co-Gen 260 - East Plaster White Good Non-Friable See Above Included Above
None Detected
4. Co-Gen 260 - West Concrete Wall White Good Non-Friable Concrete Walls &
Ceiling throughout Co-Gen 260
900 Sq. Ft.
None Detected
5. Co-Gen 260 - Ceiling Concrete Ceiling White Good Non-Friable See Above Included Above
None Detected
6. Co-Gen 260 - North Concrete Wall White Good Non-Friable See Above Included Above
None Detected
7. Co-Gen 260 - South Concrete Floor White Good Non-Friable Concrete Floor
throughout Co-Gen 260
450 Sq. Ft.
None Detected
8. Co-Gen 260 - South Concrete Floor White Good Non-Friable See Above Included Above
None Detected
9. Co-Gen 260 - Center Concrete Floor White Good Non-Friable See Above Included Above
None Detected
10. Co-Gen 260 - South Fiberglass Pipe Insulation Pink Good Friable
Fiberglass Pipe Insulation
throughout Co-Gen 260
300 Sq. Ft.
None Detected
Client: FJUHSD Bainbridge Project #: 20027913.13
Project Name: La Habra High School – Aquatics Facility Inspector/Sampler: Marco Silva
Address: 801 Highlander Avenue Date Sampled: 3/4 & 3/5/2020
La Habra, California 90631
ASBESTOS BULK SAMPLE LOG
ASBESTOS BULK SAMPLE LOG FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631
1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 2 of 5 Fax (714) 247-0025
Sample No.
Sample Location
Sample Description Color Material
Condition Friable
Non-Friable Material Location
Approx. Quantity
Laboratory Results
11. Co-Gen 260 - Center Fiberglass Pipe Insulation Yellow Good Friable See Above Included Above
None Detected
12. Co-Gen 260 - Center Fiberglass Pipe Insulation Yellow Good Friable See Above Included Above
None Detected
13. Co-Gen 260 - Center Cloth Jacket White Good Friable Cloth Jacket throughout Co-Gen 260
10 Sq. Ft.
None Detected
14. Co-Gen 260 - Center Cloth Jacket White Good Friable See Above Included Above
None Detected
15. Co-Gen 260 - Center Cloth Jacket White Good Friable See Above Included Above
None Detected
16. Co-Gen 260 - North Water Heater Tank Insulation Black Good Friable
Water Heater Tank Insulation
throughout Co-Gen 260
10 Sq. Ft.
None Detected
17. Co-Gen 260 - North Water Heater Tank Insulation Black Good Friable See Above Included
Above None
Detected
18. Co-Gen 260 - North Water Heater Tank Insulation Black Good Friable See Above Included
Above None
Detected
19. Co-Gen 260 - Exterior North Pavement Black Good Non-Friable
Pavement throughout Co-Gen 260
2,500 Sq. Ft.
None Detected
20. Co-Gen 260 - Exterior North Pavement Black Good Non-Friable See Above Included
Above None
Detected
21. Co-Gen 260 - Exterior North Pavement Black Good Non-Friable See Above Included
Above None
Detected
22. Pool Area Concrete Floor Gray Good Non-Friable Concrete Floor
throughout Pool Area
5,000 Sq. Ft.
None Detected
23. Pool Area Concrete Floor Gray Good Non-Friable See Above Included Above
None Detected
ASBESTOS BULK SAMPLE LOG FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631
1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 3 of 5 Fax (714) 247-0025
Sample No.
Sample Location
Sample Description Color Material
Condition Friable
Non-Friable Material Location
Approx. Quantity
Laboratory Results
24. Pool Area Concrete Floor Gray Good Non-Friable See Above Included Above
None Detected
25. Pool Area - West Concrete Wall White Good Non-Friable Concrete Wall
throughout Pool Area
1,000 Sq. Ft.
None Detected
26. Pool Area - West Concrete Wall White Good Non-Friable See Above Included Above
None Detected
27. Pool Area - West Concrete Wall White Good Non-Friable See Above Included Above
None Detected
28. Pool Area - West CMU Wall Blue Good Non-Friable CMU Wall
throughout Pool Area
1,500 Sq. Ft.
None Detected
29. Pool Area - West CMU Wall Blue Good Non-Friable See Above Included Above
None Detected
30. Pool Area - West CMU Wall Blue Good Non-Friable See Above Included Above
None Detected
31. Acid Room – East Concrete Wall Gray Good Non-Friable Concrete Wall
Throughout Acid Room
375 Sq. Ft.
None Detected
32. Acid Room – East Concrete Wall Gray Good Non-Friable See Above Included Above
None Detected
33. Acid Room – East Concrete Wall Gray Good Non-Friable See Above Included Above
None Detected
34. Acid Room - Center Concrete Floor Gray Good Non-Friable Concrete Floor
Throughout Acid Room
450 Sq. Ft.
None Detected
35. Acid Room - Center Concrete Floor Gray Good Non-Friable See Above Included Above
None Detected
36. Acid Room - Center Concrete Floor Gray Good Non-Friable See Above Included Above
None Detected
ASBESTOS BULK SAMPLE LOG FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631
1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 4 of 5 Fax (714) 247-0025
Sample No.
Sample Location
Sample Description Color Material
Condition Friable
Non-Friable Material Location
Approx. Quantity
Laboratory Results
37. Co-Gen 260 Roof - West Rolled Roofing White Good Non-Friable
Rolled Roofing throughout
Co-Gen 260 Roof
2000 Sq. Ft.
None Detected
38. Co-Gen 260 Roof - Center Rolled Roofing White Good Non-Friable See Above Included
Above None
Detected
39. Co-Gen 260 Roof - East Rolled Roofing White Good Non-Friable See Above Included
Above None
Detected
40. Co-Gen 260 Lower Roof - West Shingle Roofing Gray Good Non-Friable
Shingle Roofing throughout Co-Gen
260 Lower Roof
650 Sq. Ft.
None Detected
41. Co-Gen 260 Lower Roof - Center Shingle Roofing Gray Good Non-Friable See Above Included
Above None
Detected
42. Co-Gen 260 Lower Roof - East Shingle Roofing Gray Good Non-Friable See Above Included
Above None
Detected
43. Co-Gen 260 Roof - Center Pipe Mastic White Good Non-Friable
Pipe Mastic throughout
Co-Gen 260 Roof
35 Sq. Ft.
None Detected
44. Co-Gen 260 Roof - East Pipe Mastic White Good Non-Friable See Above Included
Above None
Detected
45. Co-Gen 260 Roof - West Pipe Mastic White Good Non-Friable See Above Included
Above None
Detected
46. Co-Gen 260 Roof - West Curb Mastic White Good Non-Friable
Curb Mastic throughout
Co-Gen 260 Roof
80 Sq. Ft.
None Detected
47. Co-Gen 260 Roof - Center Curb Mastic White Good Non-Friable See Above Included
Above None
Detected
48. Co-Gen 260 Roof - East Curb Mastic White Good Non-Friable See Above Included
Above None
Detected
49. Co-Gen 260 Roof - West HVAC Mastic White Good Non-Friable
HVAC Mastic throughout
Co-Gen 260 Roof
30 Sq. Ft.
None Detected
ASBESTOS BULK SAMPLE LOG FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631
1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 5 of 5 Fax (714) 247-0025
Sample No.
Sample Location
Sample Description Color Material
Condition Friable
Non-Friable Material Location
Approx. Quantity
Laboratory Results
50. Co-Gen 260 Roof - Center HVAC Mastic White Good Non-Friable See Above Included
Above None
Detected
51. Co-Gen 260 Roof - East HVAC Mastic White Good Non-Friable See Above Included
Above None
Detected
52. Co-Gen 260 Roof - North Perimeter Mastic White Good Non-Friable
Perimeter Mastic throughout
Co-Gen 260 Roof
120 Sq. Ft.
None Detected
53. Co-Gen 260 Roof - East Perimeter Mastic White Good Non-Friable See Above Included
Above None
Detected
54. Co-Gen 260 Roof - West Perimeter Mastic White Good Non-Friable See Above Included
Above None
Detected
55. Co-Gen 260 Roof - Center Vibration Damper Black Good Non-Friable
Vibration Damper throughout
Co-Gen 260 Roof
10 Sq. Ft.
None Detected
56. Co-Gen 260 Roof - East Vibration Damper Black Good Non-Friable See Above Included
Above None
Detected
57. Co-Gen 260 Roof – West Vibration Damper Black Good Non-Friable See Above Included
Above None
Detected
58. Acid Room – East Concrete Wall Green Good Non-Friable Concrete Wall
throughout Acid Room
400 Sq. Ft.
None Detected
59. Acid Room – East Concrete Wall Green Good Non-Friable See Above Included Above
None Detected
60. Acid Room – SoutH Concrete Wall Green Good Non-Friable See Above Included Above
None Detected
PACM- 61. Inside Pool Pool Basin Plaster White Good Non-Friable Pool Basin
throughout Pool 1,000 Sq. Ft.
PACM/ >1% ACM
PACM – 62. Pool Trim Concrete Coping Multi Good Non-Friable Concrete Coping
around Pool Trim 250
Sq. Ft. PACM/
>1% ACM
LA Testing5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / [email protected]
332004730LA Testing Order:
Customer ID: 32BAIN21
Customer PO:
Project ID:
Attention: Phone:Karlin Cisco (714) 403-7191
Fax:Bainbridge Environmental Consultants (714) 247-0025
Received Date:1322 Bell Avenue 03/07/2020 11:35 AM
Analysis Date:Suite 1N 03/10/2020
Collected Date:Tustin, CA 92780 03/04/2020
Project: La Habra HS/ Aquatic facility
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1
332004730-0001
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Co-gen 260- East -
Plaster
2
332004730-0002
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Co-gen 260- South -
Plaster
3
332004730-0003
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Co-gen 260- East -
Plaster
4
332004730-0004
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Co-gen 260- West -
Concrete wall
5
332004730-0005
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Co-gen 260- Ceiling -
Concrete ceiling
6
332004730-0006
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Co-gen 260- North -
Concrete wall
7
332004730-0007
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Co-gen 260- South -
Concrete floor
8
332004730-0008
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Co-gen 260- South -
Concrete floor
9
332004730-0009
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Co-gen 260- Center -
Concrete floor
10
332004730-0010
None DetectedNon-fibrous (Other)12%Glass88%Silver/Pink
Fibrous
Heterogeneous
Co-gen 260- South -
Fiber glass pipe
insulation
11
332004730-0011
None DetectedNon-fibrous (Other)2%Glass98%Yellow
Fibrous
Homogeneous
Co-gen 260- Center -
Fiber glass pipe
insulation
12
332004730-0012
None DetectedNon-fibrous (Other)25%Glass75%White/Yellow
Fibrous
Heterogeneous
Co-gen 260- Center -
Fiber glass pipe
insulation
13
332004730-0013
None DetectedNon-fibrous (Other)2%Glass98%White/Purple
Fibrous
Homogeneous
Co-gen 260- Center -
Cloth jacket
14
332004730-0014
None DetectedNon-fibrous (Other)2%Glass98%White/Purple
Fibrous
Homogeneous
Co-gen 260- Center -
Cloth jacket
15
332004730-0015
None DetectedNon-fibrous (Other)2%Glass98%White/Purple
Fibrous
Homogeneous
Co-gen 260- Center -
Cloth jacket
16-Insulation 1
332004730-0016
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Co-gen 260- North -
Water heater tank
insulation
Initial report from: 03/10/2020 18:07:20
Page 1 of 5ASB_PLM_0008_0001 - 1.78 Printed: 3/10/2020 3:07 PM
LA Testing5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / [email protected]
332004730LA Testing Order:
Customer ID: 32BAIN21
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
16-Insulation 2
332004730-0016A
None DetectedNon-fibrous (Other)100%Black/Yellow
Non-Fibrous
Heterogeneous
Co-gen 260- North -
Water heater tank
insulation
17
332004730-0017
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Co-gen 260- North -
Water heater tank
insulation
18
332004730-0018
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Co-gen 260- North -
Water heater tank
insulation
19
332004730-0019
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Co-gen 260- Exterior
North - Pavement
20
332004730-0020
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Co-gen 260- Exterior
North - Pavement
21
332004730-0021
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Co-gen 260- Exterior
North - Pavement
22
332004730-0022
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Pool area - Concrete
floor
23
332004730-0023
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Pool area - Concrete
floor
24
332004730-0024
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Pool area - Concrete
floor
25-Concrete
332004730-0025
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Pool area - West -
Concrete wall
25-Caulk
332004730-0025A
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Pool area - West -
Concrete wall
26
332004730-0026
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Pool area - West -
Concrete wall
27
332004730-0027
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Pool area - West -
Concrete wall
28
332004730-0028
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Pool area - West -
CMU wall
29
332004730-0029
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Pool area - West -
CMU wall
30
332004730-0030
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Pool area - West -
CMU wall
31
332004730-0031
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Acid room - East -
Concrete wall
32
332004730-0032
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Acid room - East -
Concrete wall
33
332004730-0033
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Acid room - East -
Concrete wall
Initial report from: 03/10/2020 18:07:20
Page 2 of 5ASB_PLM_0008_0001 - 1.78 Printed: 3/10/2020 3:07 PM
LA Testing5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / [email protected]
332004730LA Testing Order:
Customer ID: 32BAIN21
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
34
332004730-0034
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Acid room - Center -
Concrete floor
35
332004730-0035
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Acid room - Center -
Concrete floor
36
332004730-0036
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Acid room - Center -
Concrete floor
37
332004730-0037
None DetectedNon-fibrous (Other)92%Glass8%White/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
West - Rolled roofing
38
332004730-0038
None DetectedNon-fibrous (Other)92%Glass8%White/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
Center - Rolled
roofing
39
332004730-0039
None DetectedNon-fibrous (Other)92%Glass8%White/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
East - Rolled roofing
40-Shingle
332004730-0040
None DetectedNon-fibrous (Other)92%Glass8%Gray/Black
Fibrous
Heterogeneous
Co-gen 260 Lower
Roof - West - Shingle
roofing
40-Felt
332004730-0040A
None DetectedNon-fibrous (Other)50%Cellulose50%Black
Fibrous
Heterogeneous
Co-gen 260 Lower
Roof - West - Shingle
roofing
41-Shingle
332004730-0041
None DetectedNon-fibrous (Other)92%Glass8%Gray/Black
Fibrous
Heterogeneous
Co-gen 260 Lower
Roof - Center -
Shingle roofing
41-Felt
332004730-0041A
None DetectedNon-fibrous (Other)50%Cellulose50%Black
Fibrous
Heterogeneous
Co-gen 260 Lower
Roof - Center -
Shingle roofing
42-Shingle
332004730-0042
None DetectedNon-fibrous (Other)92%Glass8%Gray/Black
Fibrous
Heterogeneous
Co-gen 260 Lower
Roof - East - Shingle
roofing
42-Felt
332004730-0042A
None DetectedNon-fibrous (Other)50%Cellulose50%Black
Fibrous
Heterogeneous
Co-gen 260 Lower
Roof - East - Shingle
roofing
43
332004730-0043
None DetectedNon-fibrous (Other)88%Cellulose
Glass
10%
2%
White/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
Center - Pipe mastic
44
332004730-0044
None DetectedNon-fibrous (Other)88%Cellulose
Glass
10%
2%
White/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
East - Pipe mastic
45
332004730-0045
None DetectedNon-fibrous (Other)88%Cellulose
Glass
10%
2%
White/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
West - Pipe mastic
46-Mastic
332004730-0046
None DetectedNon-fibrous (Other)87%Cellulose
Glass
10%
3%
White/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
West - Curb mastic
46-Shingle
332004730-0046A
None DetectedNon-fibrous (Other)90%Glass10%Gray/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
West - Curb mastic
47-Mastic
332004730-0047
None DetectedNon-fibrous (Other)87%Cellulose
Glass
10%
3%
White/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
Center - Curb mastic
47-Shingle
332004730-0047A
None DetectedNon-fibrous (Other)92%Glass8%Gray/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
Center - Curb mastic
Initial report from: 03/10/2020 18:07:20
Page 3 of 5ASB_PLM_0008_0001 - 1.78 Printed: 3/10/2020 3:07 PM
LA Testing5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / [email protected]
332004730LA Testing Order:
Customer ID: 32BAIN21
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
47-Felt
332004730-0047B
None DetectedNon-fibrous (Other)82%Synthetic18%Black
Fibrous
Homogeneous
Co-gen 260 Roof -
Center - Curb mastic
48-Mastic
332004730-0048
None DetectedNon-fibrous (Other)89%Cellulose
Glass
8%
3%
White/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
East - Curb mastic
48-Shingle
332004730-0048A
None DetectedNon-fibrous (Other)90%Glass10%Gray/Black
Fibrous
Heterogeneous
Co-gen 260 Roof -
East - Curb mastic
48-Insulation
332004730-0048B
None DetectedNon-fibrous (Other)40%Cellulose60%Tan
Fibrous
Homogeneous
Co-gen 260 Roof -
East - Curb mastic
49
332004730-0049
None DetectedNon-fibrous (Other)92%Cellulose8%Black
Fibrous
Homogeneous
Co-gen 260 Roof -
West - HVAC mastic
50-Mastic 1
332004730-0050
None DetectedNon-fibrous (Other)92%Cellulose8%Black
Fibrous
Homogeneous
Co-gen 260 Roof -
Center - HVAC mastic
50-Mastic 2
332004730-0050A
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Heterogeneous
Co-gen 260 Roof -
Center - HVAC mastic
51
332004730-0051
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Co-gen 260 Roof -
East - HVAC mastic
52
332004730-0052
None DetectedNon-fibrous (Other)98%Synthetic2%White/Black
Non-Fibrous
Heterogeneous
Co-gen 260 Roof -
North - Perimeter
mastic
53
332004730-0053
None DetectedNon-fibrous (Other)98%Synthetic2%White/Black
Non-Fibrous
Heterogeneous
Co-gen 260 Roof -
East - Perimeter
mastic
54
332004730-0054
None DetectedNon-fibrous (Other)98%Synthetic2%White/Black
Non-Fibrous
Heterogeneous
Co-gen 260 Roof -
West - Perimeter
mastic
55
332004730-0055
None DetectedNon-fibrous (Other)80%Synthetic20%Black
Fibrous
Homogeneous
Co-gen 260 Roof -
Center - Vibration
damper
56
332004730-0056
None DetectedNon-fibrous (Other)80%Synthetic20%Black
Fibrous
Homogeneous
Co-gen 260 Roof -
East - Vibration
damper
57
332004730-0057
None DetectedNon-fibrous (Other)80%Synthetic20%Black
Fibrous
Homogeneous
Co-gen 260 Roof -
West - Vibration
damper
58
332004730-0058
None DetectedNon-fibrous (Other)100%Gray/Green
Non-Fibrous
Heterogeneous
Acid room - East -
Concrete wall
59
332004730-0059
None DetectedNon-fibrous (Other)100%Gray/Green
Non-Fibrous
Heterogeneous
Acid room - East -
Concrete wall
60
332004730-0060
None DetectedNon-fibrous (Other)100%Gray/Green
Non-Fibrous
Heterogeneous
Acid room - South -
Concrete wall
Initial report from: 03/10/2020 18:07:20
Page 4 of 5ASB_PLM_0008_0001 - 1.78 Printed: 3/10/2020 3:07 PM
LA Testing5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / [email protected]
332004730LA Testing Order:
Customer ID: 32BAIN21
Customer PO:
Project ID:
Analyst(s)
Brittany Quiring (53)
Monica Luna (18)
Michael DeCavallas, Laboratory Manager
or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim
Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without
written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All
samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of
the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.
Samples analyzed by LA Testing Huntington Beach, CA NVLAP Lab Code 101384-0, CA ELAP 1406
Initial report from: 03/10/2020 18:07:20
Page 5 of 5ASB_PLM_0008_0001 - 1.78 Printed: 3/10/2020 3:07 PM
OrderID: 332004730
Page 1 Of 9
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 12
APPENDIX B
LEAD-BASED PAINT XRF FIELD DATA AND ANALYTICAL RESULTS
1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 1 of 5 Fax (714) 247-0025
XL No Side Building Room Source Substrate Color Results Positive Approx. mg/cm2 Negative Quantity
1 N/A Calibration Calibration Calibration Wood Green 1.0 Positive Time: 5:50 am
2 N/A Calibration Calibration Calibration Wood Green 0.9 Negative Time: 5:50 am
3 N/A Calibration Calibration Calibration Wood Green 1.0 Positive Time: 5:51 am
4 A Aquatic Facility Co-Gen 260 Wall Plaster White 0.0 Negative N/A
5 B Aquatic Facility Co-Gen 260 Wall Plaster White -0.1 Negative N/A
6 C Aquatic Facility Co-Gen 260 Wall Concrete White 0.1 Negative N/A
7 D Aquatic Facility Co-Gen 260 Wall Concrete White 0.2 Negative N/A
8 D Aquatic Facility Co-Gen 260 Door Frame Metal Gray -0.1 Negative N/A
9 D Aquatic Facility Co-Gen 260 Door (Interior) Wood Blue -0.1 Negative N/A
10 D Aquatic Facility Co-Gen 260 Door (Exterior) Wood Blue 0.0 Negative N/A
11 C Aquatic Facility Co-Gen 260 Pipe Run Metal White 0.1 Negative N/A
12 C Aquatic Facility Co-Gen 260 Pipe Run Metal White 0.1 Negative N/A
13 A Aquatic Facility Co-Gen 260 Pipe Run Metal Green 0.1 Negative N/A
Client: FJUHSD Client Project #: N/A
Site: La Habra High School – Aquatics Facility Bainbridge Project #: 20027913.13
Address: 801 Highland Avenue Inspector/Sampler: Marco Silva
La Habra, California 90631 Date Sampled: 3/4/2020
Lead-Based Paint XRF Sampling Log
XRF Lead-Based Paint Sampling Log
FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631
1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 2 of 5 Fax (714) 247-0025
XL No Side Building Room Source Substrate Color Results Positive Approx. mg/cm2 Negative Quantity
14 C Aquatic Facility Co-Gen 260 EMS Control Panel #1 Metal Gray 0.0 Negative N/A
15 C Aquatic Facility Co-Gen 260 Floor Concrete Gray 0.3 Negative N/A
16 D Aquatic Facility Co-Gen 260 (Exterior) Wall Concrete Gray/
Blue 0.1 Negative N/A
17 A Aquatic Facility Co-Gen 260 (Exterior) Wall Concrete Gray/
Blue 0.0 Negative N/A
18 B Aquatic Facility Co-Gen 260 (Exterior) Wall Concrete Gray/
Blue 0.3 Negative N/A
19 C Aquatic Facility Co-Gen 260 (Exterior) Wall Concrete Gray/
Blue 0.2 Negative N/A
20 C Aquatic Facility Acid Room Louver Metal Gray/
Blue 0.5 Negative N/A
21 C Aquatic Facility Acid Room Louver Metal Gray/
Blue 0.5 Negative N/A
22 C Aquatic Facility Acid Room Electrical Conduit Metal Gray/
Blue 0.0 Negative N/A
23 C Aquatic Facility Acid Room Electrical Conduit Metal Gray/
Blue -0.6 Negative N/A
24 C Aquatic Facility Acid Room Electrical Panel Metal Gray/
Blue 0.1 Negative N/A
25 A Aquatic Facility Acid Room Wall Concrete Green 0.8 Negative N/A
26 D Aquatic Facility Acid Room Wall Concrete Green 0.5 Negative N/A
27 B Aquatic Facility Acid Room Wall Concrete Green 0.6 Negative N/A
28 B Aquatic Facility
Pool Area Pool Trim Concrete Blue 0.2 Negative N/A
XRF Lead-Based Paint Sampling Log
FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631
1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 3 of 5 Fax (714) 247-0025
XL No Side Building Room Source Substrate Color Results Positive Approx. mg/cm2 Negative Quantity
29 B Aquatic Facility Pool Area Pool Trim Concrete White 0.2 Negative N/A
30 A Aquatic Facility Pool Area Pool Trim Concrete Red 2.1 Positive 7
Sq. Ft.
31 C Aquatic Facility Pool Area Pool Trim Concrete Red 1.4 Positive See 30
32 C Aquatic Facility Pool Area Pool Trim Concrete Yellow 0.1 Negative N/A
33 C Aquatic Facility Pool Area Pool Trim Concrete Blue 0.4 Negative N/A
34 C Aquatic Facility Pool Area Lifeguard Chair Metal Blue 0.1 Negative N/A
35 B Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 1.0 Positive 5,929
Sq. Ft.
36 B Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 9.0 Positive See 35
37 C Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 3.8 Positive See 35
38 D Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 8.8 Positive See 35
39 D Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 8.7 Positive See 35
40 A Aquatic Facility Pool Area Pool Interior Wall Lining Concrete White 8.1 Positive See 35
41 B Aquatic Facility Pool Area Bleachers Wood Blue 0.1 Negative N/A
42 B Aquatic Facility Pool Area Bleachers Wood Blue 0.0 Negative N/A
43 B Aquatic Facility Pool Area Bleachers Wood Blue 0.0 Negative N/A
XRF Lead-Based Paint Sampling Log
FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631
1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 4 of 5 Fax (714) 247-0025
XL No Side Building Room Source Substrate Color Results Positive Approx. mg/cm2 Negative Quantity
44 C Aquatic Facility Pool Area Wall Concrete White 0.2 Negative N/A
45 C Aquatic Facility Pool Area Wall Concrete White 0.3 Negative N/A
46 C Aquatic Facility Pool Area Wall Concrete White 0.2 Negative N/A
47 C Aquatic Facility Pool Area Wall Concrete White 0.4 Negative N/A
48 C Aquatic Facility Pool Area Brick & Mortar Brick Blue 0.1 Negative N/A
49 C Aquatic Facility Pool Area Brick & Mortar Brick Blue 0.1 Negative N/A
50 C Aquatic Facility Pool Area Brick & Mortar Brick Blue 0.0 Negative N/A
51 C Aquatic Facility Pool Area Brick & Mortar Brick Blue 0.3 Negative N/A
52 C Aquatic Facility Pool Area Diving Board Metal White -0.4 Negative N/A
53 C Aquatic Facility Pool Area Diving Board Metal White 0.1 Negative N/A
54 D Aquatic Facility Co-Gen 260 Roof Fascia Board Wood Blue 0.0 Negative N/A
55 D Aquatic Facility Co-Gen 260 Roof Fascia Board Metal Blue 0.1 Negative N/A
56 A Aquatic Facility Roof Rolled Roofing Wood White -0.1 Negative N/A
57 C Aquatic Facility Roof Fascia Board Concrete Blue 0.2 Negative N/A
58 N/A Calibration Calibration Calibration N/A Green 1.0 Positive Time: 9:55 am
XRF Lead-Based Paint Sampling Log
FJUHSD – La Habra High School – Aquatics Facility - 801 Highlander Avenue, La Habra, California 90631
1322 Bell Avenue, Suite 1N Tel (714) 247-0024 Tustin, CA 92780 5 of 5 Fax (714) 247-0025
XL No Side Building Room Source Substrate Color Results Positive Approx. mg/cm2 Negative Quantity
59 N/A Calibration Calibration Calibration N/A Green 1.0 Positive Time: 9:56 am
60 N/A Calibration Calibration Calibration N/A Green 1.0 Positive Time: 9:56 am
-END OF REPORT-
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 13
APPENDIX C
ASBESTOS AND LEAD-BASED PAINT INSPECTOR’S STATE CERTIFICATIONS
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 14
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 15
APPENDIX D
ASBESTOS AND LEAD-BASED PAINT XRF SAMPLE LOCATION DRAWINGS
Fullerton Joint Union High School District La Habra High School – Aquatic Facility
Asbestos Bulk Sample Location Drawing (Co-Gen 260 & Acid Room Samples 1-21, 31-36 & 58-60)
1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025
21
20
19
36 58 59 35 60
33
32 34 31
4
6
2
10 3
13 14
11 1
15 12
8
7
5
9
16, 17, 18
Fullerton Joint Union High School District La Habra High School – Aquatic Facility
Asbestos Bulk Sample Location Drawing (Pool Area Samples 22-30)
1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025
25
23
28 30
26
29 27
24
22
Fullerton Joint Union High School District La Habra High School – Aquatic Facility
Asbestos Bulk Sample Location Drawing (Roof Samples 37-57)
1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025
47
37 54
53
43
56 50
38
42 46
55
49
45
39
52
57
48
51
44
40 41
Fullerton Joint Union High School District La Habra High School – Aquatic Facility
Lead-XRF Sample Location Drawing – Co-Gen 260 & Acid Room (For Reference Only)
1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025
D
C
B
A
Fullerton Joint Union High School District La Habra High School – Aquatic Facility
Lead-XRF Sample Location Drawing – Pool Area (For Reference Only)
1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025
A
D
C
B
Fullerton Joint Union High School District La Habra High School – Aquatic Facility
Lead-XRF Sample Location Drawing – Roof (For Reference Only)
1322 Bell Avenue, Suite 1N, Tustin, California 92870 Tel: (714) 247-0024 Fax: (714) 247-0025
A
D
C
B
Fullerton Joint Union High School District Bainbridge Environmental Consultants, Inc. La Habra High School – Aquatics Facility Comprehensive Asbestos and Lead-Based Paint XRF Survey Report March 11, 2020
Page 16
APPENDIX E
SURVEY PHOTOGRAPHS
Fullerton Joint Union High School District La Habra High School – Aquatics Facility
Survey Photographs
Fullerton Joint Union High School District La Habra High School – Aquatics Facility
Survey Photographs
Fullerton Joint Union High School District La Habra High School – Aquatics Facility
Survey Photographs
Fullerton Joint Union High School District La Habra High School – Aquatics Facility
Survey Photographs
Fullerton Joint Union High School District La Habra High School – Aquatics Facility
Survey Photographs
Fullerton Joint Union High School District La Habra High School – Aquatics Facility
Survey Photographs