comuted tomograhy dr. amr a. abd-elghany. it is a non-invasive medical imaging modality that...

38
COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany

Upload: lisa-reeves

Post on 22-Jan-2016

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

COMUTED TOMOGRAHY

Dr. Amr A. Abd-Elghany

Page 2: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate tomographic (‘slices’) of the area scanned.Four classifications of the types of scans: -Abdominal-Bone-Head-Vascular

COMPUTED TOMOGRAPHY

Page 3: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate
Page 4: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Tomo = image // to long axis of the body

CT = image is transverse to the body

Page 5: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

X-ray image of the thorax CT scan of the thorax

CAT scan.flv

Page 6: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Why computed tomography?

• Mathematical principles of CT were first developed in 1917 by Radon.

• Proved that an image of an unknown object could be produced if one had an infinite number of projections through the object.

• Plain film imaging reduces the 3D patient anatomy to a 2D projection image.

• Used to determine: the extent of Trauma, Location and type of the tumor, status of blood vessels, pre surgical planning.

Page 7: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

• Density at a given point on an image represents the x-ray attenuation properties within the patient along a line between the x-ray focal spot and the point on the detector corresponding to the point on the image.

• With a conventional radiograph information with respect to the dimension parallel to the x-ray beam is lost.

• Large area x-ray beams used in conventional radiography produces considerable scattered radiation that causes blurring images.

Why computed tomography? Cont.

Page 8: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate
Page 9: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

CT the beginning• Was formally introduced in 1972 by

a British engineer Sir Godfrey Hounsfield

• The first scan was done in 1971, of the brain

• Physicist Allan Cormack also invented a similar machine in the United States

• Both Cormack and Hounsfield were awarded the Nobel Prize in 1979

• First clinical scanners were installed in 1974

• Was a revolutionary invention in terms of medical imaging

Page 10: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate
Page 11: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

PRINCIPLE OF COMPUTED TOMOGRAPHIC IMAGING

I = I0e−μx

In early CT imaging devices (“scanners”) a narrow x-ray beam is scanned across a patient in synchrony with a radiation detector on the opposite side of the patient. If the beam is mono-energetic or nearly so, the transmission of x rays I through the patient is

Page 12: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

x-ray tube

Page 13: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Basic CT scanner component

• Gantry.

• X-ray tube.

• Detector.

• Control console.

Computed Tomography Machine

Page 14: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

X

Page 15: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Y

Page 16: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Z

Page 17: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

ISOCENTER

Page 18: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Gantry• CT X-ray tube.

• High voltage generator.

• Detector array.

• Data acquisition system.

• Slip ring: eliminated the

need of cables and enables the continuous rotation of the gantry components (electromechanical technology).

Page 19: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Detector Elements

• Capture energy that has not been attenuated by the patient

Page 20: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

CT Generations1st Generation: Rotate/

translate, pencil beam 1972• 1 to 3 x-ray detectors used.• Parallel ray geometry.• X-ray tube only able to rotate180 degrees

at 1-degree intervals.• About 4.5 min/slice.• Whole chest can be scanned at 1 hr.• Pencil beam allowed very efficient scatter reduction, best of all scanner generations.

Page 21: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

1st generation cont.

CT scanner 1st Generation.mp4

Page 22: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Second Generation 1973

• Fan-shaped x-ray beam• 30 or more detectors• 20 seconds per slice or 10 minutes for a

40 slice exam.• 180 degree rotation.• Long data reconstruction time.\.

CT scanner 2nd Generation.mp4

Page 23: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Third Generation 1974 • Fan-shaped x-ray beam.• 960 detectors opposite the x-ray tube.• Complete 360 degree rotation

Rotate/Rotate movement. • One rotation = one slice.• Second data acquisition could be made as

the tube and detectors move in the opposite direction.

• Time reduced to 1 sec per slice.

CT scanner 3rd Generation.mp4

Page 24: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

3rd generation configuration

Page 25: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Fourth Generation 1975

• Developed in 1980’s. • Fixed ring of as many as 4800

detectors, completely surrounding the patient, Rotate only movement

• Rotating x-ray tube provides short bursts of radiation

• Detectors collect the remnant radiation to reconstruct into an image

• 1 minute for multiple slices

Page 26: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

• 4th generation configuration

CT scanner 4th Generation2.mp4

Page 27: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Fifth GenerationStationary/stationary 1984

• Developed specifically for cardiac tomographic imaging.

• No conventional x-ray tube; large arc of tungsten encircles patient and lies directly opposite to the detector ring.

• Electron beam steered around the patient to strike the annular tungsten target.

• Capable of 50msec scan times; can produce fast frame rat CT movies of the beating heart

Page 28: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

CT scanner 5th Generation - YouTube.flv

Page 29: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Modern Scanners

• No longer categorize into Generations• Contemporary (modern) CT scanners

are either third or fourth generation designs.

• Scanners are categorized by tube and detector movement

• Slip Ring Technology: connects generator with tube (no cables)

Page 30: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Spiral CT 1986 (Helical CT-volumetric CT)6th generation• Helical (continuous rotation) CT scanners

acquire data while the table is moving• By avoiding the time required to translate

the patient table, the total scan time required to image the patient can be much shorter

• Allows the use of less contrast agent.• In some instances the entire scan be done

within a single breath-hold of the patient

Page 31: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Multiple detector array (Multi-slice CT)1999

7th generation

• When using multiple detector arrays, the collimator spacing is wider and more of the x-rays that are produced by the tube are used in producing image data– Opening up the collimator in a single array

scanner increases the slice thickness, reducing spatial resolution in the slice thickness dimension

– With multiple detector array scanners, slice thickness is determined by detector size, not by the collimator

Page 33: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Procedure • Indications• If physician could not diagnose by plain x-ray.• CT can detect masses, fluids, mediastina and

chest wall lesions, pulmonary embolism (blocking of main artery of the lung or one of its branches).

• Patient preparation.• Contrast media administration, fasting 4-6 hours.

• Patient positioning.• Chest, abdomen, pelvis=AP.• Brain, spine=lateral.

• Scanogram

Page 34: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Scanogram cont. • CT will ask you slice thickness 1cm or

more or less.• CT will ask you if you will inject contrast or

not (lung =no, mediastinum=yes).• Press the button.• The table will be moved 1cm.• Each slice will have 2 images(mediastinal window, lung window)

1 = root of aorta2 = pulmonary outflow3 = left atrium4 = left pulmonary vein5 = superior vena cava6 = descending aorta

Page 35: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Benefit of CT scan• Unlike other imaging methods, fast.

• Painless, non-invasive & Accurate

• CT Scanning offers detailed views.

• Diagnosis made with the assistance of CT can eliminate the need for invasive exploratory surgery & surgical biopsy.

• Information to show cross section of body tissue & organ

• Use wide range of clinical problems.

Page 36: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Risks of CT scan

CT scan is not generally indicated for pregnant women.

CT scan does involves high radiation exposure

Risk of serious allergic reaction to iodine containing contrast media.

Page 37: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

C.T Scan of Blood Vessel

Page 38: COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany. It is a non-invasive medical imaging modality that combines the use of X-rays and computer processing to generate

Normal Abdomen CT Oral & IV contrast level of spleen & liver CT angiogram

shows pulmonary vessels