configuration and sensor layout
DESCRIPTION
CONFIGURATION AND SENSOR LAYOUT. z. W (+)/y. S(-) N (+)/x. E (-). AC7. Hammer Hit Direction. AC4. Accelerometer-AC. AC6. VibPilot. AC3. No Gains is used. Calibration Constant are entered manually - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/1.jpg)
CONFIGURATION AND SENSOR LAYOUT
AC5
AC6
AC7 Accelerometer-AC
AC1
HAMMER
VibPilot
AC4
AC3
AC2
No Gains is used.Calibration Constant
are entered manuallyAll sensors is set up in such a way they are measuring positive direction in DAQ settings.Each accelerometer is connected to the channel associated with it’s number (i.e. AC1-Channel 1)(Hammer-Channel 8).
S(-) N(+)/xW(+)/y
E(-)
Hammer Hit Direction
z
![Page 2: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/2.jpg)
DETAIL 1
DETAIL 1
DETAIL 1
DETAIL 2
DETAIL 3
DETAIL 3
DETAIL 3
![Page 3: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/3.jpg)
IN-PLANE MOTION SENSOR DETAILS
![Page 4: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/4.jpg)
SENSOR DETAILS FOR IN-PLANE TESTSType Brand Model Serial Range Additional Info Location Calibration
AC-1 PCB - ICP U348B09 1214 +/- 50 g1-2000 HZ
Magnetic MountA27-080
Center / South SideGround Floor Beam 100 mV/g
AC-2 PCB - ICP U348B09 1056 +/- 50 g1-2000 HZ
Magnetic MountA27-080
1st FloorSouth Side
Gusset Plate100 mV/g
AC-3 PCB - ICP U348B09 1212 +/- 50 g1-2000 HZ
Magnetic MountA27-080
2nd FloorSouth Side
Gusset Plate100 mV/g
AC-4 PCB - ICP 353B33 79388 +/- 50 g1-4000 HZ
Magnetic MountA27-080
3rd FloorSouth Side
Gusset Plate100 mV/g
AC-5 PCB - ICP U348B09 1213 +/- 50 g1-2000 HZ
Magnetic MountA27-080
1st Floor, North Side Column, Outside of
outer FlangeAligned with beam
web
100 mV/g
AC-6 PCB - ICP U348B09 1038 +/- 50 g1-2000 HZ
Magnetic MountA27-080
2nd Floor, North Side Column, Outside of
outer FlangeAligned with beam
web
100 mV/g
AC-7 PCB - ICP 353B33 79599 +/- 50 g1-4000 HZ
Magnetic CapA27-080
3rd Floor, North Side Column, Outside of
outer FlangeAligned with beam
web
100 mV/g
EX-1 PCB - ICP 086D50 24659 22240 N Medium HardRed Plastic Tip - 0.22 mV/N
![Page 5: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/5.jpg)
Detail 1 - In-Plane
W8x67
W10x30
Direction ofMeasurement
Direction ofMeasurement
5-1/4’’
![Page 6: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/6.jpg)
Detail 2 - In-Plane
Direction ofMeasurement
5-1/4’’W10x30
90’’
![Page 7: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/7.jpg)
![Page 8: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/8.jpg)
OUT-OF-PLANE MOTION SENSOR DETAILS
![Page 9: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/9.jpg)
SENSOR DETAILS FOR OUT-OF-PLANE TESTSType Brand Model Serial Range Additional Info Location Calibration
AC-1 PCB - ICP U348B09 1214 +/- 50 g1-2000 HZ
Magnetic MountA27-080
Center / East SideGround Floor Beam 100 mV/g
AC-2 PCB - ICP U348B09 1056 +/- 50 g1-2000 HZ
Magnetic MountA27-080
1st FloorEast Side
Gusset Plate100 mV/g
AC-3 PCB - ICP U348B09 1212 +/- 50 g1-2000 HZ
Magnetic MountA27-080
2nd FloorEast Side
Gusset Plate100 mV/g
AC-4 PCB - ICP 353B33 79388 +/- 50 g1-4000 HZ
Magnetic MountA27-080
3rd FloorEast Side
Gusset Plate100 mV/g
AC-5 PCB - ICP U348B09 1213 +/- 50 g1-2000 HZ
Magnetic MountA27-080
1st Floor, West Side Column, Web 100 mV/g
AC-6 PCB - ICP U348B09 1038 +/- 50 g1-2000 HZ
Magnetic MountA27-080
2nd Floor, West Side Column, Outside of
outer FlangeAligned with beam
web
100 mV/g
AC-7 PCB - ICP 353B33 79599 +/- 50 g1-4000 HZ
Magnetic MountA27-080
3rd Floor, West Side Column, IOutside of
outer FlangeAligned with beam
web
100 mV/g
EX-1 PCB - ICP 086D50 24659 22240 N Medium HardRed Plastic Tip - 0.22 mV/N
![Page 10: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/10.jpg)
Detail 1 - Out-of-Plane
W8x67
W10x30
Direction ofMeasurement
Direction ofMeasurement
5-1/4’’
![Page 11: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/11.jpg)
Detail 2 -Out-of-Plane
Direction ofMeasurement
5-1/4’’W10x30
90’’
![Page 12: CONFIGURATION AND SENSOR LAYOUT](https://reader036.vdocument.in/reader036/viewer/2022081503/56815abf550346895dc883d3/html5/thumbnails/12.jpg)