configurations type cloud vnx
TRANSCRIPT
![Page 1: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/1.jpg)
1© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Configurations Types Private Cloud
Erwan QuignaAdvisory Account TC
![Page 2: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/2.jpg)
2© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
A Single Unified Application Solution
Lowest $/IO
Lowest $/GB
Fully Automated
Hybrid Array
Optimized for Virtualized Workloads
VDI Home Dir.
![Page 3: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/3.jpg)
3© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
The New FLASH-Optimized Hybrid ArrayThe performance of FLASH with the efficiency of tiering
Takes full advantage of the low latency of FLASH FLASH-optimized software and data services
Delivers progressively lower $/IOPS at scale
Moves inactive data to NL-HDDs for lowest $/GB
Controller
SSDsNEW
HDDs
![Page 4: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/4.jpg)
4© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Unlocking the Power of FlashNew Clean-Sheet design
SP A SP B
32 LANES CMI
32CPU
CORES
160LANES
PCIE G3
1500SSDs or
HDDs
SAS 2.0SAS 2.0
FC, iSCSI, NFS, pNFS,
and CIFS
22PCIE
IO SLOTSFC, iSCSI, NFS, pNFS, and CIFS
![Page 5: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/5.jpg)
5© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Dynamic Multicore Optimization
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Core Number
Core
Uti
lizati
on
Static Core Utilization
Breakthrough Midrange Innovation!
RAID I/O DRAM Cache FAST Cache Data Services Management Available
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 150%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Core Number
Core
Uti
lizati
on
43
![Page 6: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/6.jpg)
6© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
VNX5400 VNX5600 VNX5800 VNX7600 VNX8000VNX5200
New EMC VNX Series with MCxSix new VNX platforms
SIMPLE. EFFICIENT. POWERFUL. PROTECTED.
UP TO 6 PB CAPACITY
UP TO 4X Performance, Just as Affordable
![Page 7: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/7.jpg)
7© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
More for Less with MCx™Industry-revolutionizing performance efficiency
File Data Base VMs
122,500
185,000
1,100
580,796NFS IOPS
735,193O-racle and
SQL ServerI-OPS
6,600VMs
6X4X4X
Note: NFS based on SPECsfs2008, RDBMS is 8K IO size. Both on CLASSIC LUNs. VMs is based on a VM footprint of 50 IOPS by 100 GB on THIN Pool LUNs. All three are SSD-based tests.
![Page 8: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/8.jpg)
8© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
MCx™: Leading NFS Response Time
NFS File Serving
Vendor I16-Node Cluster
Vendor N8-Node Cluster
Vendor ODual Node
Vendor D4+4 Node Cluster
Source: www.spec.org SPECsfs2008_nfs.v3
2.6XFASTER
![Page 9: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/9.jpg)
9© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Transactional NAS Latency ImprovementExample: VMware on NFS
VNX VNX Next Gen
IOP
S
Late
ncy
Read Latency
Write Latency
IOPS
3x IOPS
60% Faster
![Page 10: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/10.jpg)
10© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
4XMORE TRANSACTIONS
Industry-Leading OLTP Price/Performance
Single Array
VNX8000735K IOPS*
VNX7500200K IOPS
*Source: Demartek, Oracle + SQL Mixed OLTP
![Page 11: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/11.jpg)
11© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
New VNX Block Deduplication
Lowers Flash capacity requirements by 50% or more
Deduplication at 8KB granularity– Out of band: minimizes I/O impact
Ideal for virtual machines and virtual desktops with redundant data across multiple sources
DedupeEngine
UserChanges
IndexDatabase
LUN
Free Pool
Read
De-dupe
Storage Pool
LUN
![Page 12: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/12.jpg)
12© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
The Right Protection for Every Application Need
Point-in-time recoveryUp to 256 snaps per LUN for block and 112 snaps per file system
Automated protection for virtualized applicationsMaintain SLAs with application protection as a service
Bi-directional, continuous remote replication RPO at or close to zero with RecoverPoint Remote
Local continuous replicationDVR-like recovery to any point in time using RecoverPoint Local
Efficient backup and recovery Purpose-built deduplication appliances accelerate backup and recovery
Continuous operationsThe exact same information, read and write accessible at the same time, in two separate locations
![Page 13: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/13.jpg)
13© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Three Paths to Cloud InfrastructureOptimized for virtualization and end-user computing
Component-based
Best-of-Breed Infrastructure
VSPEX
Proven Infrastructure
Vblock
Converged Infrastructure
NEW
NEW
![Page 14: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/14.jpg)
14© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
EMC VNX Series Models
VNX5200 VNX5400 VNX5600 VNX5800 VNX7600 VNX8000Max FAST Cache 600 GB 1 TB 2 TB 3 TB 4.2 TB 4.2 TB
Max drives 125 250 500 750 1000 1500
Drive types Flash, SAS, NL-SAS
File System modules
Data Movers 1, 2 or 3 1 to 4 1 to 4 2 to 6 2 to 8 2 to 8
I/O slots per DM 3 3 3 4 4 5
Memory per DM 6 GB 6 GB 12 GB 12 GB 24 GB 24 GB
Protocols CIFS, NFS, pNFS
Storage Pool
modules
Storage Processors 2 2 2 2 2 2
I/O ports per SP 2 2 2 2 2 2
I/O slots per SP 3 4 5 5 5 11
Memory per SP 16 GB 16 GB 24 GB 32 GB 64 GB 128 GB
Cores per SP 4 4 4 6 8 16
Protocols Fibre Channel, Fibre Channel over Ethernet, iSCSI
![Page 15: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/15.jpg)
![Page 16: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/16.jpg)
Erwan Quigna
Configuration Type VNX New Generation
![Page 17: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/17.jpg)
17© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Configuration
• Configurations Types issues des White Paper VSPEX
• SAN ou NAS
• 2 types de configuration– Consolidation Oracle virtualisé– Virtualisation pure
• Options communes– Réplication, Vplex, Module VCops
![Page 18: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/18.jpg)
18© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Configuration Consolidation Oracle
• Configuration de Base Oracle VM : – VNX5400, FAST Cache 4*SSD200G, 39TiB– 1 Pool For VM DataStore FAST VP enabled
• 20 * 600 10k RAID 4+1, 2 * 100G SSD R1– 8.3TB usable, 50 VMs, 25-50 iops/VM
– 1 Pool for Oracle Redo Log• 5 * 600 10k RAID 5+1 : 2.1TiB
– 1 Pool for Oracle FRA Backup• 8 * 2 TB NL SAS RAID 6 6+2 : 10.6TiB
– 1 Pool for Oracle DATA• 25 * 600 10k + 2 * 100G SSD R1 + 6 * 2TB
– 17.5TB 20 000 IOPS OLTP2
– 10 slots disponibles pour par exemple 10 * 600G 10k
![Page 19: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/19.jpg)
19© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Configuration type des VMs
• SMALL– 1 vcpu / 2 GB RAM / 25 iops / 100 GB
• LARGE– 4 vcpu / 8 GB RAM / 50 iops / 200 GB
• VMWare ESX 5
• Blade– 2 * 10GbE + 2 * 8GbFC | 4 * 10GbE
![Page 20: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/20.jpg)
20© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
VNX 5400 Configuration de Base
• VNX 5400– 1 Base Oracle
Env / VMWare Cluster
– Optional FAST VP for Data File
– 1 Extension– NAS or SAN
Connectivity– VMWare Plug in– Optional VCOps
plug in
![Page 21: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/21.jpg)
21© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Première Extension
Evolutions Possibles
• VNX5400– Base+1
Extension
• VNX5600– Base+2
Extensions
• VNX5800– Base+4
Extensions
![Page 22: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/22.jpg)
22© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Evolutivité des configurations types VM Oracle
Competition
70%
IOPS
Volu
métr
ie
1000005000025000 75000 125000 150000
40TiB
80TiB
120TiB
160TiB
200TiB
VNX5800
VNX5600
VNX5400
![Page 23: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/23.jpg)
23© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Caractéristiques commerciale et technique
Utile TiB U kVA k€
VNX5400Base 39 9 1.95
1 extension 78 18 2.74
VNX5600Base 39 9 1.951 extension 78 18 2.74
2 extension 117 27 3.53
VNX5800
Base 39 9 1.951 extension 78 18 2.742 extension 117 27 3.533 extension 156 36 4.32
4 extension 195 45 5.11
Utile TiB W/TiB €/GiB
VNX5400Base 39 50
1 extension 78 35
VNX5600Base 39 50
1 extension 78 35
2 extension 117 30
VNX5800
Base 39 50
1 extension 78 35
2 extension 117 30
3 extension 156 27
4 extension 195 26
![Page 24: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/24.jpg)
24© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Configuration virtualisation
• Configuration de Base Virtualisation:
– VNX5400, FAST Cache 4*SSD200G, 50TiB
– 1 Pool For VM DataStore FAST VP enabled
– 85* 600 10k RAID 4+1, 2 * 100G SSD R1, 12 * 2TB NL SAS 4+2
• 500 VMs, 25-50 iops/VM
![Page 25: configurations type cloud VNX](https://reader031.vdocument.in/reader031/viewer/2022020921/55d01b2ebb61eb4c438b47b0/html5/thumbnails/25.jpg)
25© Copyright 2014 EMC Corporation. All rights reserved.© Copyright 2014 EMC Corporation. All rights reserved.
Caractéristiques commerciale et technique
Utile TiB U kVA k€
VNX5400Base 50 12 1.59
1 extension 100 24 2.72
VNX5600Base 50 12 1.59
1 extension 100 24 2.72
2 extension 150 36 3.85
VNX5800
Base 50 12 1.59
1 extension 100 24 2.722 extension 150 36 3.85
3 extension 200 48 4.98
4 extension 250 60 6.11
Utile TiB W/TiB €/GiB
VNX5400Base 50 31.8
1 extension 100 27.2
VNX5600Base 50 31.8
1 extension 100 27.2
2 extension 150 25. 7
VNX5800
Base 50 31.8
1 extension 100 27.2
2 extension 150 25.7
3 extension 200 24.9
4 extension 250 24.44