connect graphics card connect to network & clickshare connect

1
Connect Graphics Card Connect to network & ClickShare Connect Power Supply NRC-200 Quick Install Sheet 4 3 2 1 What’s in the box ? NRC-200 • NGP controller • 2 chassis mounting brackets • Quick Start Guide (this) • Safety Manual • USB recovery stick • 1 DVI-VGA adapter • 4 chassis feet • 4 screws 3.9x6.5 (to fix brackets to bottom plate) • 4 screws M4x8 (to fix brackets to housing) • 2 part number labels • 2 serial number labels • 2x2 MAC address labels Accessories pack • 2 DP to HDMI cables • 2 DP to DVI cables • 1 Ethernet cable • 3 Power cables (EU, UK and US) NRC-200 rear view port 1 port 2 2 DP output ports 1 DVI output port port 3 2 1 This port is only used for boot messages LAN connectors (RJ45) LAN cable LAN ClickShare power cable Power rating: 110-240 V~, 5-3 A, 50-60 Hz Power up the NRC-200 by means of the power button at the front or the rear. On tablet PC or normal PC with MS Windows7 or 8, 64-bit: Connect to same network as your NRC-200. The Client GUI makes use of the Bonjour Services to detect your NRC-200 devices on the network. Install Bonjour on your system; Bonjour Print Services for Windows v2.0.2 is available on this site: http://support.apple.com/downloads/DL999/en_US/BonjourPSSetup.exe Download the Client GUI from www.barco.com/NRC_client Install client Run client 1 2 3 4 5 6 7 8 Welcome window: Start configuration. General settings Select the NRC you want to configure. The pin code is 1234 by default. Output settings Define the screen output settings. Source settings Configure the input sources. ClickShare settings Final configuration This page shows a summary of all the changes that will be applied. Press Finish. The Wizard will apply all the changes listed above and reboot automatically. Select Wizard Go to Config Wizard 9 10 Link display to either port 2 or port 3 (only 2 ports can be used simultaneously) © 2015 Barco N.V. | All rights reserved. Subject to change without notice. R591430-00 System Configuration

Upload: buihanh

Post on 19-Jan-2017

232 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Connect Graphics Card Connect to network & ClickShare Connect

Connect Graphics Card

Connect to network & ClickShare

Connect Power Supply

NRC-200 Quick Install Sheet

4

3

2

1

What’s in the box ?NRC-200• NGP controller• 2 chassis mounting brackets• Quick Start Guide (this)• Safety Manual • USB recovery stick• 1 DVI-VGA adapter• 4 chassis feet• 4 screws 3.9x6.5 (to fix brackets to bottom plate)• 4 screws M4x8 (to fix brackets to housing)• 2 part number labels• 2 serial number labels• 2x2 MAC address labels

Accessories pack

• 2 DP to HDMI cables• 2 DP to DVI cables• 1 Ethernet cable• 3 Power cables (EU, UK and US)

NRC-200 rear view

port 1

port 2

2 DP output ports1 DVI output port

port 3 2

1

This port is only used for boot messages

LAN connectors (RJ45)

LAN cable

LAN ClickShare

power cable

Power rating:110-240 V~, 5-3 A, 50-60 Hz

Power up the NRC-200 by means of the power button at the front or the rear.

On tablet PC or normal PC with MS Windows7 or 8, 64-bit:Connect to same network as your NRC-200.

The Client GUI makes use of the Bonjour Services to detect your NRC-200 devices on the network. Install Bonjour on your system; Bonjour Print Services for Windowsv2.0.2 is available on this site:http://support.apple.com/downloads/DL999/en_US/BonjourPSSetup.exe

Download the Client GUI from www.barco.com/NRC_clientInstall clientRun client

1

2

3

4

5

6

7

8

Welcome window: Start configuration.

General settingsSelect the NRC you want to configure.The pin code is 1234 by default.

Output settingsDefine the screen output settings.

Source settingsConfigure the input sources.

ClickShare settings

Final configurationThis page shows a summary of all the changes that will be applied.Press Finish.The Wizard will apply all the changes listed above and reboot automatically.

Select Wizard Go to Config Wizard

9

10

Link display to either port 2 or port 3 (only 2 ports can be used simultaneously)

© 2015 Barco N.V. | All rights reserved. Subject to change without notice.

R591

430-

00DRAFTSystem Configuration