Construction
Manual
The details and information in this book are for guidance purposes only and are not site specific.
Named materials must be used to conform with C.A.T.G. certification. Refer to the relevant design
manual and panel drawings for the site, which should be read in conjunction with the approved
Building Regulation drawings and must be adhered to and take priority over standard details. FOR
FIXING DETAILS REFER TO ERECTION MANUAL and DESIGN MANUAL.
ISSUE 9
2014
Sips Eco Panels MANUAL.
CONTENTS
CM410 CLOSED EAVES
CM411 CLOSED EAVES AT WINDOW HEAD
CM412 FLUSH EAVES
CM413 OPEN EAVES
CM414 TYPICAL RIDGE AND ATTIC DETAILS.
CM415 ROOF PANEL TO PANEL CONNECTION
4.00 ROOF DETAILS
CM510 PLASTERBOARD SPECIFICATION
CM511 INTERNAL DOOR LINING
CM512 METER BOX DETAIL
CM513 FLUE DETAIL
CM514 WALL HUNG BOILER DETAIL
CM515 CHIMNEY DETAIL
CM516 CHIMNEY SECTION
CM517 WATER TANK DETAIL
CM518 NOT USED
CM519 NOT USED
CM520 NOT USED
CM521 DRILLING HOLES THROUGH INTERNAL WALLS
CM522 ALLOWANCE FOR VERTICAL MOVEMENT
WHEN USING MASONRY CLADDING
CM523 SUPPORT TO HEAVY OBJECTS
EXTERNAL WORKS
CM610 TREE PROTECTION NOTES
CM611 TREE PROTECTION ZONE SHEET 1
CM612 TREE PROTECTION ZONE SHEET 2
CM613 SELF-BUILD PROGRAMME
CM1 FOREWORD
CM2 NOT USED
CM3 PARTY WALL ACT SHEET 1
CM4 PARTY WALL ACT SHEET 2
CM5 TYPICAL EXTERNAL WALL
CM6 GLOSSARY OF BUILDING TERMS SHEET 1
CM7 GLOSSARY OF BUILDING TERMS SHEET 2
CM8 SCAFFOLD DETAILS
CM9 SCAFFOLD SECTION
GENERAL INFORMATION AND GLOSSARY OF TERMS
1.00 FOUNDATIONS AND GROUND FLOOR DETAILS
CM110 DPC RELATIONSHIP WITH CHIPBOARD FLOOR
CM111 DPC RELATIONSHIP WITH SCREEDED FLOOR
CM112 RESTRAINT STRAP FIXING 1
CM112.1 RESTRAINT STRAP FIXING 2
CM113 WIND PORTAL FOUNDATION DETAILS
CM114 SOLEPLATE FIXING
CM115 JUNCTION OF INTERNAL LOAD BEARING WALL
AND FOUNDATIONS
CM116 MOBILITY DOOR FRAME AND SCREED
CM117 MOBILITY DOOR FRAME AND CHIPBOARD
2.00 EXTERNAL WALL DETAILS
CM210 EXTERNAL WALL AND TRUSS ROOF CEILING
CM211 RIM BEAM
CM212 JUNCTION OF EXTERNAL AND INTERNAL WALLS
CM213 DOOR AND WINDOW FIXING SHEET 1
CM214 DOOR AND WINDOW FIXINGS SHEET 2
CM215 INSTALLATION OF uPVC WINDOWS SHEET 1
CM216 INSTALLATION OF uPVC WINDOWS SHEET 2
CM217.1 PARTY WALL EDGE SEALING DETAIL1
CM217.2 PARTY WALL EDGE SEALING DETAIL2
CM217.3 PARTY WALL EDGE SEALING DETAIL3
CM218 EXTERNAL SINGLE DOOR OPENING
CM219 CLADDING DETAIL - TIMBER
CM220 CLADDING DETAIL - RENDER
CM221 CLADDING DETAIL - RENDER (MOVEMENT JOINT)
CM222 CLADDING DETAIL - TILING
CM223 EXTERNAL WALL CORNER
3.00 INTERNAL DETAILS
CM310 NOGGINGS AND PANEL CONNECTION
CM311 PLASTERBOARD FIXING DETAIL
CM312 MID FLOOR SOUND INSULATION
CM313 WALL SOUND INSULATION
CM314 JUNCTION OF LOADBEARING WALL WITH FLOOR
CM315 INTERNAL WALL TO WALL JUNCTION
CM316 NON LOADBEARING WALL AND FLOOR SHEET
CM317 WALL JUNCTION IN 4 DIRECTIONS
CM318 NON LOADBEARING WALL PARALLEL TO JOISTS
5.00 MISCELLANEOUS DETAIL
CONTENTS
IS
SU
E 9
2014
FOREWORD
The enclosed details are indicative of current practice and are issued for guidance
only.
Any timber frame structure manufactured and supplied by Sips eco panels will be
designed specifically for the project and will be detailed accordingly. Construction
of the timber frame must be carried out in accordance with the drawings and details
issued for construction.
Sips eco panels reserve the right to amend details as required to reflect revised
practices and changes in Building Regulations.
Whilst we believe that the contents reflect current Building Regulation requirements
it is the builder's or project manager's overall responsibility to ensure compliance
and to seek approval from Building Control Officers or other certifiers, as no
warranty is given or should be implied as to the accuracy of the information for any
specific application.
THIS MANUAL MUST BE READ IN CONJUNCTION WITH NHBC AND OTHER
GUARANTOR'S STANDARDS, ALL RELEVANT BRITISH STANDARDS AND
CODES OF PRACTICE AND ANY OTHER SPECIFICATIONS RELATIVE TO
YOUR PROJECT.
CONSTRUCTION (DESIGN & MANAGEMENT) REGULATIONS (1994)
All construction projects large and small are subject to the CDM Regulations
(1994). Essentially the regulations make the client responsible for implementing
aspects of health and safety on their site.
If the development will be for a domestic client or will be less than 30 days in
duration then the responsibility for Health and Safety is then passed onto the main
contractor. In most cases for Sips eco panels the client is the main contractor.
In all cases the client may devolve this responsibility to a CDM Planning
Supervisor, who will act on the clients behalf. Please refer to a Planning
Supervisor for advice.
FOREWORD
IS
SU
E 9
2014
CM
1
The Party Wall etc. Act 1996 came into force on 1st July 1997 throughout England and Wales.
If you intend to carry out building work which involves one of the following categories:
· Work on an existing wall or structure shared with another property (section 2 of the Act)
· Building a free standing wall or a wall of a building up to or astride the boundary with a
neighbouring property (section 1 of the Act)
· Excavating near a neighbouring building (section 6 of the Act)
You must find out whether that work falls within the Act (your project manager will be able to
advise you on this). If it does, you must notify all affected neighbours. A notice must be given
even where that work will not extend beyond the centre line of a party wall.
The Act covers:
· Works that are going to be carried out directly to an existing party wall or structure
· New building at or astride the boundary line between properties
· Excavation within 3 or 6 metres of a neighbouring building or structure depending on the depth
of the hole or foundations.
The Act provides a framework for preventing and resolving disputes in relation to party walls,
boundary walls and excavations near neighbouring buildings. It is based on some tried and tested
provisions of the London Buildings Acts, which applied in inner London for many decades.
On the following page a brief, simple outline is given to explain the Act.
THIS IS NOT AN AUTHORATIVE INTERPRETATION OF THE LAW. You must remember that
reaching an agreement with your neighbour under the Act DOES NOT remove the possible need
for planning permission or building regulations approval.
In all cases please refer to a party wall surveyor for advice.
THE PARTY WALL etc. ACT (1996)
INTRODUCTION
PARTY WALL ACT
SHEET ONE
IS
SU
E 9
2014
CM
3
The Act recognises two main types of party wall. These are referred to as a 'party wall' or a 'party
fence wall'.
A wall is a 'party wall' if:
(i) it forms part of a building and stands astride the boundary of land belonging to two (or more)
different owners; or
(ii) it separates buildings and it either
(a) stands astride the boundary of land belonging to two (or more) different owners; or
(b) stands wholly on one owner's land, but is used by two (or more) owners to separate their
buildings. Where one person has built the wall in the first place and another has butted their
building up against it without constructing their own wall, only the part of the wall that does the
separating is 'party' - sections on either side or above are not 'party'.
A wall is a 'party fence wall' if it is a wall which is not part of a building, that stands astride the
boundary line between lands of different owners and is used to separate those lands (for example
a garden wall). This does not include such things as wooden fences.
The Act also uses the expression 'party structure'. This is a wider term, which could be a party
wall or a floor partition or other structure separating buildings or parts of buildings approached by
separate staircases or entrances (for example flats).
If you plan to:
· Excavate, or construct foundations for a new building or structure, within 3 metres of a
neighbouring owner's building or structure where that work will go deeper than the neighbour's
foundations; or
· Excavate, or construct foundations for a new building or structure, within 6 metres of a
neighbouring owner's building or structure where that work will cut a line drawn downwards at
45o from the bottom of the neighbour's foundations;
You must inform the adjoining owner by serving a notice. The notice must also state whether you
propose to strengthen or safeguard the foundations of the building or structure belonging to the
adjoining owner. The notice must be accompanied by plans.
The Act contains no enforcement procedures for failure to serve a notice. However, if you start
work without having first given notice in the proper way, adjoining owners may seek to stop your
work through a court injunction or seek other legal redress.
THE PARTY WALL etc. ACT (1996)
WHAT IS A PARTY WALL?
PARTY WALL ACT
SHEET TWO
IS
SU
E 9
2014
CM
4
DPC
HOLDING DOWN STRAPS SUPPLIED BY
Sips Eco Panels AND FIXED BY
BRICKWORK CONTRACTOR. SEE CM112
FINISHED
GROUND
LEVEL
OPEN PERPENDS TO
VENTILATE AND DRAIN
THE CAVITY SPACED
AT MAX. 1500mm c/c
THE EXTERNAL WALL CONSISTS OF TWO PARTS;
THE LOADBEARING SIP PANEL.
THE OUTER CLADDING.THIS MAY BE A HEAVYWEIGHT CLADDING SUCH AS BRICKWORK SUPPORTED
INDEPENDENTLY OFF OF FOUNDATIONS, OR A LIGHTWEIGHT CLADDING ATTACHED TO THE TIMBER
FRAME SUCH AS; RENDER, HANGING TILES OR TIMBER BOARDING. REFER TO OTHER SECTIONS OF THIS
MANUAL CM219 - CM222. SEE NOTE BELOW
SOLEPLATE - THIS PROVIDES A LEVEL
AND ACCURATE POSITIONED BASE ON
WHICH THE SUPERSTRUCTURE WILL BE FIXED,
INCLUDING THE FLOOR IN THE CASE OF
SUSPENDED TIMBER GROUND FLOORS.
IT ALSO PROVIDES A NAILING PLATE FOR
THE SIPS PANEL AND PROTECTS THE DPC
VENTILATED
CAVITY
DPC
FLOOR DPM LAPPED WITH
DPC AND TURNED UP TO
LAP WITH VAPOUR
CONTROL LAYER.
FLOOR FINISH
SEE CM110 & CM111
VAPOUR CONTROL LAYER
(VCL SUPPLIED & FITTED BY
OTHERS BEHIND)
BREATHER
MEMBRANE
SIP PANEL
BATTENS FOR SERVICE VOID (WHERE REQUIRED).
HELICAL TIES (NOT SUPPLIED). STAINLESS
STEEL HELIFIX TimTie 6 or SIMPSON
STRONGTIE TIMBER FRAME WALL TIES
SWT50 SPACED AT MAX 600mm c/c
HORIZONTALLY AND 450mm c/c
VERTICALLY
THE CONSTRUCTION OF EXTERNAL WALLS MUST COMPLY WITH
APPROVED DOCUMENT B OF THE BUILDING REGULATIONS
PARTICULARLY IF THE CLADDING IS COMBUSTIBLE AND WITHIN 1M OF
THE BOUNDARY, WITH PARTICULAR ATTENTION TO PART B4
HIGHLIGHTING THE SPECIFIC MINIMUM REQUIREMENTS OF FIRE
RESISTANCE.THIS INCLUDES OPENABLE AREAS.
FOR PLASTERBOARD
SPECIFICATION REFER TO
DRAWING CM44
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
TYPICAL
EXTERNAL WALL
IS
SU
E 9
2014
CM
5
Aggregate: sand and/or stone mixture, used with cement to make concrete
Architrave: wooden strips around a door or window, which cover the join between the door lining and wall
Barge board: the board that hides and protects the outside edge of a gable
Barge foot: Timber piece at the bottom of the bargeboard, blocking off the gap under the eaves
Base rail; also known as bottom plate: the lower horizontal member of a timber wall panel
Batten: a piece of timber fixed in place for something to be attached to - notably, rows of battens are put
on the roof to hold the tiles. These are also used to fix plasterboard to off of the SIPS panel.
Blocking: pre-cut timbers that are fitted between joists above a wall panel on which further wall panels are
fitted, and to fix plasterboard at ceiling level
Breather membrane: waterproof sheeting applied to the outside of a SIPS panel to keep water out but to
let the frame 'breathe'
Cavity: the gap between the external and internal walls of a house. Cavity construction is common in this
country. A drained and vented cavity is maintained between the external cladding (brickwork or similar)
and the timber structure to remove any water that penetrates the outer skin in extreme conditions while the
venting increases the safety margin against condensation risk.
Cavity closers: These close the cavity in a cavity wall. For instance at eaves level and at window and
door openings. They prevent smoke from penetrating the building. They could be sleeved mineral wool or
timber. These must be treated timber and cut ends brushed with preservative. A separate DPC should be
fitted on the outside to protect the timber.
Cement: A powder that, when mixed with water and aggregate forms concrete, screed, mortar or render. It
is a term occasionally used for glue.
Compactor: machine with vibrator that compacts material - e.g. hardcore in foundations
Concrete: a mixture of water, sand, stone and a binder (usually cement) that hardens to a stone like mass.
Corbel: projection of brickwork from a wall, for instance to support a beam or roof truss.
Courses: Parallel layers of brickwork, blocks, tiles etc. A soldier course is a course laid vertically - for
instance, above a window
Decking: term used to describe any timber floor area
DPC and DPM: damp proof course and damp proof membrane respectively. A DPC is a wide strip of
plastic laid along the base of the brickwork skin to prevent rising damp. A dpm is plastic sheeting laid
under or over the concrete slab to prevent damp rising
Dry lining: plasterboard finish to walls fitted to battens off of the SIPS panel.
Eaves: The lowest, overhanging part of a sloping roof, or the area under it. Usually used to fix gutters to.
Efflorescence: Powdery white salts on the face of brickwork as it dries out, created by water moving
through the wall from gypsum or pyrite in the clay and coal the bricks are fired with. When the water dries
out, salt deposits are left behind. Efflorescence can be greatly reduced, if not prevented, by keeping bricks
dry during laying, which includes covering them at night.
Fascia: board fitted over the ends of the roof trusses and carries the gutter
Felt: sheets laid beneath the roof tiles to waterproof the trusses below.
Flashing: lead used to dress up walls at external joints for instance around chimneys.
Frog: a depression in one or more faces of a brick. Such bricks should be laid with the frog facing up
Gable: the end of a wall that is vertically triangular in shape
GLOSSARY OF BUILDING
TERMS SHEET ONE
IS
SU
E 9
2014
CM
6
Gable ladder: pre-made component which abuts the first roof truss and forms the overhand on a gable roof.
Gallows brackets: Triangular brackets used to support the weight of an
item such as a bay window or porch
Joist: a beam that supports a floor or ceiling
Lintel: a beam above doors and windows and other openings used for supporting the structure above.
Open Perpends: The cavity between the SIps wall and brick or block cladding should be self draining. The
openings (Open Perpends) provide for drainage; Open Perpends at 1.5 m maximum centres should be kept clear
of mortar. Proprietary plastic ventilators of perpend width are available. Open Perpends should be used above
wherever the cavity is bridged with a horizontal cavity tray,such as a lintols or roof abutments etc.
OSB: Oriented strand board is an engineered wood product formed by laying strands (flakes) of wood in specific
orienations. It is used on the outside faces of a SIPS panel sandwiching the expanded poystyrene. It can also be
used in many ways the same as plywood and is becoming a more popular form of board.
Oversite: concrete base laid over the foundations. Normally the ground floor slab.
Panel: a section of wall, floor, ceiling or roof pre-fabricated and forming part of a timber frame kit
Profiles: timber boards that are used initially to mark the foundation boundaries
Purlin: a beam in roof construction, which supports the rafters or SIPS roof panels.
Quilt: term used to describe the mineral wool often supplied in rolls 300-900mm wide used for insulation of internal
walls and floors
Rafter feet: end of rafter where gutter or fascia is fixed
Ring beam: perimeter timber in a joist frame floor
Rim beam: Similar to a ring beam but acting as a continuous lintel around the perimeter of a building.
Sarking: a detail of roof boarding common in Scotland that can be used to give extra strength and
weatherproofing. The entire roof is covered by sheathing boards nailed to it before the roof is felted and then tiled.
Screed: smooth sand and cement mixture applied to finish off a concrete floor
Setting out: marking out on the ground the area where the house is going to be built
Skim: thin topcoat of plaster. It can be applied to plasterboard to give a slightly silkier feel to the wall. Most
plasterboard is however, finished 'dry' when it is taped and jointed, ready for immediate decoration
Soffit: flat plywood fixed beneath the eaves between the back of the
fascia and the wall to conceal the rafters. It can incorporate a soffit ventilation strip to ventilate the roof space if
breathable roofing felt is not used
Soleplate: a treated timber anchored to the base to fix and set out wall panels
Stack: soil pipe running from top of the house down to the drain. The top is open to the outside allowing the drain
to ventilate. Some stacks are non-venting and these will have a screwed down cover. These must be joining a drain
run that is ventilated at its furthest point.
Studwork: the timber framework of internal walls
Tacking: nailing of plasterboard to battens without driving the nail fully home
Truss: prefabricated frame for the roof construction. Fink trusses are used as standard and are cheaper than attic
trusses, but the latter will allow space in the loft to be utilised for accommodation. SIPS are used to create a roof
allowing the loft area to be used as usable space where possible.
Vapour control layer (vcl): 500g gauge polythene sheeting. An airtight skin to prevent interstitial condensation.
Fitted to the inside face of an external wall or internal room where steam can occur it protects the wall from
condensation.
Verge: the point at which the brickwork in a gable meets the roof. It is the overhang of the roof that should not
exceed 50mm.
Wallplate: horizontal members attached to the end of studding in internal panels. Head binders are also referred
to as wallplates.
Wall ties: span the cavity to help support the brickwork of the outer walls. Helifix TimTie 6 or stainless steel timber
frame wall ties may be used. These are screwed into the panel and laid on the mortar bed of brickwork.
For further useful building terms you may wish to refer to the Penguin Dictionary of Building
GLOSSARY OF BUILDING
TERMS SHEET TWO
IS
SU
E 9
2014
CM
7
Platform Level
Platform Level
Platform Level
Platform Level
2100
APPRO
X
DORMER WINDOW.
PROVIDE SCAFFOLD TO FRONT OF
WHEN ROOF IS CONSTRUCTED
600mm BELOW SOFFIT/
LOWEST EAVES LEVEL.
TO
SU
IT
DESIG
N
2100
ABO
VE
S.S.L
TYPICAL SCAFFOLD ELEVATION.
Site Access Notes:
3000mm minimum clear space to be left adjacent to where
the sips wall panels will be unloaded from the lorry, to allow
wall panels to be loaded into ground floor positions & onto
first floor.
NOTES:
THIS DRAWING SHOWS THE SCAFFOLD REQUIREMENT FOR
ERECTION OF SIPS PANELS ONLY. IT IS NOT THE REQUIRED
SCAFFOLD FOR THE BRICKWORK CONTRACTOR.
FOR SINGLE STOREY BUILDINGS SET PLATFORM AT 2000 AND 2400
SCAFFOLD DETAILS
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
8
NOTE: THIS SCAFFOLDING IS FOR THE ERECTION OF THE TIMBER FRAME ONLY
IT IS NOT THE REQUIRED SCAFFOLD FOR THE BRICKWORK CONTRACTOR.
2100 T
O P
LA
TF
OR
M F
RO
M S
.S
.L.
Scaffold to be an independent
structure, with no ties to the
timber frame.
L I N
E O
F SIPS T I M
B E R F R A M
E
950-1150 handrail
SCAFFOLDING TO THE FULL PERIMETER OF THE SIPS FRAME WILL BE REQUIRED TO GIVE A
FULL WORKING LIFT AT EACH FLOOR LEVEL AND AT ROOF LEVEL A MINIMUM 910mm BELOW
WALLPLATE LEVEL (TOP OF PANEL) TOGETHER WITH ANY LIFTS AT GABLE ENDS TO ENABLE
PEAK PANELS AND VERGE DETAILS TO BE COMPLETED.
SUITABLE SECURE LADDER ACCESS IS REQUIRED AT ALL LEVELS AND IS TO BE PROVIDED AND
FIXED BY THE MAIN CONTRACTOR. A CRASH MAT MUST BE SUPPLIED BY CLIENT AND HANDRAIL
MUST BE FITTED BY Sips Eco Panels AT THE APPROPRIATE TIME.
SCAFFOLD SECTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
9
MIN
.150
D.P.C.
1000 M
IN
IM
UM
300 M
IN
.
112
NO
T A
B
RIC
K C
OU
RS
E
22mm CHIPBOARD ON
VAPOUR BARRIER ON
90mm INSULATION ON
D.P.M LAPPED WITH WALL VCL ON
SUSPENDED CONCRETE SLAB
F.F.L.
450/600 x MINIMUM DEPTH AS SHOWN ON MASS
CONCRETE FOUNDATIONS TAKEN DOWN TO BEAR INTO
VIRGIN SUITABLE STRATUM. FOUNDATIONS ALSO TO
BE TAKEN DOWN MIN. 300 BELOW ANY ROOT
PRESENCE.
Sips Eco Panels RECOMMEND THE BRICKWORK SHOULD NOT BE
STARTED BEFORE THE SIPS FRAME HAS BEEN ERECTED.
RESTRAINT STRAPS (SUPPLIED BY Sips
Eco Panels) TO BE FIXED AT 1200 c/c.
BUILT INTO BRICKWORK AND SET
BELOW LEAN MIX CONCRETE CAVITY
FILL (IF REQUIRED). THESE MUST BE
FITTED BY BRICKLAYER TO SUIT BRICK
COURSES. SEE CM112.
OPEN PERPENDS AT 1500c/c
Sips Eco Panel
REFER TO CM5
MIN
. 225
CLE
AR
CA
VIT
Y
D.P.C.
EXTERNAL WALL
440 x 112 x width of wall 7N/mm2 Dense
Concrete Blocks (cut to suit finished floor depth),
Density 1950kg/m3 or similar approved on 15mm
Mortar bedding - total 155mm upstand. 155mm
concrete upstand can also be used with a GEN1
mix.' N.B. If the block wall overhangs the cavity,
the erectors must ensure the DPC is lapped over
the outside face of the coursing block to stop
water ponding on top of the overhang. It is
possible that to avoid this the block could be
flush with the floor and frame (cavity side), but a
Building Inspector may query the internal cold
bridge - this should be checked with your
Building Control and / or Insurance Inspector
(NHBC etc.)
GROUND LEVEL
150mm BELOW
LOWEST TIMBER
D.P.C.
MIN 225mm
VENTILATED VOID
TO SUIT GROUND
CONDITIONS.
THIS DRAWINGS IS TO BE READ IN CONJUNCTION WITH THE BUILDING REGULATIONS NOTES AND DRAWINGS.
HOUSE SETTING OUT RELIES ON F.F.L [Finished Floor Level] = EXTERNAL D.P.C. LEVEL.
TOP OF SOLEPLATE MAY REQUIRE CUTTING OUT AT INTERNAL AND EXTERNAL DOOR POSITIONS.
NO BRICKWORK IS TO BE CONSTRUCTED BELOW DPC LEVEL (TO EXTERNAL CAVITY SKIN) UNTIL AFTER THE
TIMBER FRAME HAS BEEN ERECTED (TO ENSURE THAT A NOMINAL 50mm CAVITY IS MAINTAINED BETWEEN
TIMBER FRAME AND OUTER SKIN).
THIS DRAWING SHOWS TRADITIONAL TRENCH FILL FOUNDATIONS AND IS NOT SITE SPECIFIC. ALL GROUND
FLOORS & FOUNDATION DEPTHS/DESIGN TO BE APPROVED BY THE LOCAL BUILDING INSPECTOR AND TO SUIT
LOCAL GROUND CONDITIONS.
FOR FOUNDATION SETTING OUT REFER TO FOUNDATION LOCATION PLAN
DPC RELATIONSHIP WITH
CHIPBOARD FLOOR
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
11
0
GROUND LEVEL
150mm BELOW
LOWEST TIMBER
MIN
.150
D.P.C.
1000 M
IN
IM
UM
300 M
IN
.
NO
T A
B
RIC
K C
OU
RS
E
F.F.L.
155
D.P.C.
MIN 225mm VENTILATED VOID
TO SUIT GROUND CONDITIONS.
SIPs Eco Panels RECOMMENDS THE BRICKWORK SHOULD NOT BE
STARTED BEFORE THE SIPS FRAME HAS BEEN ERECTED.
65mm SCREED ON
VAPOUR BARRIER ON
90mm INSULATION ON
D.P.M LAPPED WITH WALL
VAPOUR BARRIER ON
SUSPENDED CONCRETE SLAB
450/600 x MINIMUM DEPTH AS SHOWN ON MASS
CONCRETE FOUNDATIONS TAKEN DOWN TO BEAR INTO
VIRGIN SUITABLE STRATUM. FOUNDATIONS ALSO TO
BE TAKEN DOWN MIN. 300 BELOW ANY ROOT
PRESENCE.
RESTRAINT STRAPS (SUPPLIED BY (Sips Eco
Panels) TO BE FIXED AT 1200 c/c. BUILT INTO
BRICKWORK AND SET BELOW LEAN MIX
CONCRETE CAVITY FILL (IF REQUIRED). THESE
MUST BE FITTED BY BRICKLAYER TO SUIT
BRICK COURSES. SEE CM112
OPEN PERPENDS AT 1500c/c
Sips Eco Panel .
REFER TO CM5
MIN
. 225
CLE
AR
CA
VIT
Y
D.P.C.
THIS DRAWINGS IS TO BE READ IN CONJUNCTION WITH THE BUILDING REGULATIONS NOTES AND DRAWINGS.
HOUSE SETTING OUT RELIES ON F.F.L [Finished Floor Level] = EXTERNAL D.P.C. LEVEL.
TOP OF SOLEPLATE MAY REQUIRE CUTTING OUT AT INTERNAL AND EXTERNAL DOOR POSITIONS.
NO BRICKWORK IS TO BE CONSTRUCTED BELOW DPC LEVEL (TO EXTERNAL CAVITY SKIN) UNTIL AFTER THE
TIMBER FRAME HAS BEEN ERECTED (TO ENSURE THAT A NOMINAL 50mm CAVITY IS MAINTAINED BETWEEN
TIMBER FRAME AND OUTER SKIN).
THIS DRAWING SHOWS TRADITIONAL TRENCH FILL FOUNDATIONS AND IS NOT SITE SPECIFIC. ALL GROUND
FLOORS & FOUNDATION DEPTHS/DESIGN TO BE APPROVED BY THE LOCAL BUILDING INSPECTOR AND TO SUIT
LOCAL GROUND CONDITIONS.
FOR FOUNDATION SETTING OUT REFER TO FOUNDATION LOCATION PLAN
EXTERNAL WALL
440 x 140 x width of wall 7N/mm2 Dense
Concrete Blocks (cut to suit finished floor depth),
Density 1950kg/m3 or similar approved on 15mm
Mortar bedding - total 155mm upstand. 155mm
concrete upstand can also be used with a GEN1
mix.' N.B. If the block wall overhangs the cavity,
the erectors must ensure the DPC is lapped over
the outside face of the coursing block to stop
water ponding on top of the overhang. It is
possible that to avoid this the block could be
flush with the floor and frame (cavity side), but a
Building Inspector may query the internal cold
bridge - this should be checked with your
Building Control and / or Insurance Inspector
(NHBC etc.)
DPC RELATIONSHIP WITH
SCREEDED FLOOR
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
11
1
MIN
.1
50
D.P.C.
SIP PANEL WITH 500g
POLYTHENE VAPOUR
CONTROL LAYER FIXED
TO PANEL. SEE CM5
STRUCTURAL SLAB TYPE
AND DESIGN MAY VARY
MIN
. 2
25
TO
D
.P
.C
.
FOR PLASTERBOARD
SPECIFICATION REFER TO
DRAWING CM510
AUSTENITIC STAINLESS STEEL
HOLDING DOWN STRAPS
SUPPLIED BY Sips Eco Panels
AND FIXED BY BRICKWORK
CONTRACTOR TO Sips Eco
Panels BY 6no. 50x3.35mm SS
ANNULAR RINGSHANK NAILS AT
CORNERS, SIDES OF OPENINGS
AND AT 1200c/c MAX. STRAPS TO
BE SET INTO LEAN MIX
CONCRETE WHERE POSSIBLE.
SIMILAR APPROVED BY
SUPPLIER MAY BE USED.
GROUND LEVEL
150mm BELOW
LOWEST TIMBER
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
RESTRAINT STRAP
FIXING TYPE 1
IS
SU
E 9
2014
CM
11
2
GROUND LEVEL
U/S OF SOLEPLATE MUST
BE LEVEL WITH F.F.L.
FFL
FLO
OR
B
UILD
U
P B
Y O
TH
ER
S
DPM LAPPED
UNDER DPC
DPC
DENSE
7N
MIN
.150
EXTERNAL SKIN SHOWN
INDICATIVE. DETAILED
AND SUPPLIED BY OTHERS.
FISCHER FBS 6 CONCRETE
SCREW OR EQUAL AND
APPROVED TO GIVE SAFE
WORKING UPLIFT FORCE ˃ 3KN
75mm x 75mm x 10mm
SQUARE WASHER -
WASHER MUST BE TIGHT
AGAINST VERTICAL FACE
OF STRAP
BLOCK
SIPS WALL PANEL ON
20mm SOLE PLATE.
RESTRAINT STRAP
FIXING TYPE 2
CM
11
2.1
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
48
120 x 45 TIMBER FIXED TO
STEEL POST USING M12
BOLTS AT 600c/c.
145 x 20 TIMBER FIXED TO
STEEL POST (FOR
CONNECTION OF DOORS
ETC.) USING SELF DRILLING
SELF TAPPING SCREWS (BY
OTHERS)
15
2
100
100
50
50
50
250
50
50
450
152 x 152 UC CONNECTED
TO BASE USING 4 M16
KEMFIX BOLTS OR SIMILAR
600
D.P.C.
F.F.L.
MIN
. 2
25
CLE
AR
CA
VIT
Y
D.P.C.
100
100
250
25mm MAX.
GROUT
FLOOR JOIST
300
NO
MIN
AL
DOOR
OPENING
48
145 x 20 TIMBER FIXED TO
STEEL BEAM (FOR
CONNECTION OF DOORS ETC.)
USING SELF DRILLING SELF
TAPPING SCREWS (BY OTHERS)
STEELWORK ENCASED IN 19mm
FIRELINE PLASTERBOARD OR
SIMILAR WITH 5mm SKIM
PROVIDE INSULATION TO
PREVENT COLD BRIDGING
WIND PORTAL
FOUNDATION DETAIL
BASE DETAIL PLAN ON POST
SECTION THROUGH BASE SECTION THROUGH
CROSS BEAM
READ IN CONJUNCTION WITH CM5. REFER TO STRUCTURAL
ENGINEER'S CALCULATIONS FOR FOUNDATION DESIGN.
STEELWORK TO BE BLAST CLEANED
AND FINISHED IN 75 MICRON ZINC
PHOSPHATE PRIMER. WIND PORTAL
LOCATED AT GROUND FLOOR ONLY.
REINFORCEMENT DESIGNED BY
FOUNDATION ENGINEER.
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
11
3
EXPANDED POLYSTYRENE
INSULATING CORE.
45mm TREATED SW
SOLEPLATE
PANEL SECURED USING
35mm x 3.9mm COARSE
THREAD BLACK
PHOSPHATE SCREWS
OR (BZP) BRIGHT ZINC
PLATED FINISH AT 200c/c
AND 50mm FROM END.
11mm THICK
OSB OUTER
SKIN WITH
BREATHER
PAPER
EXTERNALLY.
45mm
TREATED SW
BOTTOM
PLATE
DAMP PROOF COURSE
SOLEPLATE FIXING
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
11
4
SKIRTING BOARD
PLASTERBOARD
RIGID INSULATION
SAND AND CEMENT
DPC
(OVERLAPS DPM)
DPM
AIR
BRICK
HARDCORE
DPC/DPM LAPPED
INTERNAL
440 x 140 x width of wall
7N/mm2 Dense Concrete
Blocks, Density
1950kg/m3 or similar
approved on 15mm Mortar
bedding - total 155mm
upstand. 155mm concrete
upstand can also be used
with a GEN1 mix.'
STUD WALL
JUNCTION OF INTERNAL
LOADBEARING WALL
FOUNDATIONSIS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
11
5
75 max
21
55
55
A
PP
RO
X.
TIMBER FRAME LINTOL. (NOT
SUPPLIED-CATNIC CTF5 OR
SIMILAR).
PROVIDE CAVITY TRAY
ABOVE TUCKED BEHIND
BREATHER MEMBRANE AND
LAPPED
MAKE UP OR PACKER FITTED
IN JOINERY FACTORY IN
ORDER TO MAKE FRAME
UPTO 2100mm.
VENTED DRAINAGE CHANNEL
MIN.135 DEEP
MAXIMUM LEVEL (150mm
BELOW COMMON DPC) OF
GROUND LEVEL EITHER SIDE
OF RAMP.
F.F.L./COMMON
D.P.C. LEVEL
20
RAMP
MOBILITY DOOR CILL TO
HAVE ITS OWN DPC LAPPED
INTO COMMON DPC.
ENSURE THAT DPM IS NOT
PERFORATED OR DAMAGED
AND IS ADEQUATELY LAPPED
WITH DPC.
15
M
AX
.
NOTE: DPC LEVEL LOCALLY STEPPED DOWN AT
MOBILITY DOOR THRESHOLD POSITION.
ap
pro
x
50
50 x 50 BATTEN WRAPPED IN
DPC. MIN. 75mm ABOVE
DRAINAGE CHANNEL
OVERHANG
OPEN PERPENDS AT MAX.
1500mm C/C FOR DRAINAGE
AND VENTILATION OF CAVITY.
PROVIDE A MINIMUM OF 2 IN
ALL CASES
OPEN PERPENDS AT MAX.
1500mm C/C FOR DRAINAGE
AND VENTILATION OF CAVITY.
MOBILITY DOOR FRAME
AND SCREED
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
11
6
75 max
21
55
55
A
PP
RO
X.
MAKE UP OR PACKER FITTED
IN JOINERY FACTORY IN
ORDER TO MAKE FRAME
UPTO 2100mm.
MAXIMUM LEVEL (150mm
BELOW COMMON DPC) OF
GROUND LEVEL EITHER SIDE
OF RAMP.
F.F.L.
20
RAMP
ENSURE THAT DPM IS NOT
PERFORATED OR DAMAGED
AND IS ADEQUATELY LAPPED
WITH DPC.
15
M
AX
.
NOTE: DPC LEVEL LOCALLY STEPPED DOWN AT
MOBILITY DOOR THRESHOLD POSITION.
ap
pro
x
50
50 x 50 BATTEN MIN. 75mm
ABOVE DRAINAGE CHANNEL
OVERHANG
50 x 50 TIMBER BATTEN
WRAPPED IN DPC
PREVENTING COLD BRIDGING
CHIPBOARD ON VAPOUR
CONTROL LAYER ON
INSULATION
OPEN PERPENDS FOR
DRAINAGE AND VENTILATION
TIMBER FRAME LINTOL. (NOT
SUPPLIED-CATNIC CTF5 OR
SIMILAR) USE AS CAVITY
TRAY OR PROVIDE ONE
ABOVE TUCKED BEHIND
BREATHER MEMBRANE
VENTED DRAINAGE CHANNEL
MIN.135 DEEP
MOBILITY DOOR CILL TO
HAVE ITS OWN DPC LAPPED
INTO COMMON DPC.
OPEN PERPENDS AT MAX.
1500mm C/C FOR DRAINAGE
AND VENTILATION OF CAVITY.
PROVIDE A MINIMUM OF 2 IN
ALL CASES
OPEN PERPENDS AT MAX.
1500mm C/C FOR DRAINAGE
AND VENTILATION OF CAVITY.
MOBILITY DOOR FRAME
AND CHIPBOARD
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
11
7
Sips Eco Panel
50 x 50 BATTEN
HELIFIX TIMTIE 6
OR STAINLESS
STEEL SIMPSON
STRONGTIE SWT50
TIMBER FRAME
WALL TIE
GLASS FIBRE INSULATION
SIPs ECO PANEL
REFER TO CM5
VAPOUR CONTROL
LAYER (VCL
SUPPLIED. FITTED BY
OTHERS)
THIS DETAIL TO BE EMPLOYED WHEN TRUSSED
RAFTERS ARE INSTALLED AS A COLD ROOF SYSTEM.
NOT FOR HABITABLE LOFT AREAS. REFER TO
RELEVANT STRUCTURAL CALCULATIONS AND PANEL
DRAWINGS FOR SPECIFIC SITE. READ IN CONJUNCTION
WITH CM5. PLASTERBOARD DETAILS OMITTED FOR
CLARITY. REFER TO CM44 FOR SPECIFICATION.
CEILING TIE
.
EXTERNAL WALL AND
TRUSS ROOF CEILING:
GABLE ENDIS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
0
PLASTERBOARD -
REFER TO CM510
FOR SPECIFICATION.
BATTENS
ON VCL
Sips Eco Panel
RIM BEAM
PLASTERBOARD
SOUND INSULATION
SKIRTING BOARD
VERTICAL
BATTEN ON VCL
HELIFIX TIMTIE 6
OR STAINLESS
STEEL SIMPSON
STRONGTIE SWT50
TIMBER FRAME
WALL TIES
BREATHER
MEMBRANE
VAPOUR
CONTROL LAYER
SUPPLIED. FITTED BY
OTHERS
FLOOR DECKING
120 HEAD BINDER
SERVICE VOID
Sips Eco Panel
REFER TO CM5
I-BEAM
ELEVATION
PLASTERBOARD
NOGGING
BREATHER
MEMBRANE LAPPED
TOP AND BOTTOM
AND OVER RIM BEAM
FACE OR TOP MOUNTED
HANGERS TO BE USED
WHERE SPECIFIED
READ IN CONJUNCTION
WITH CM5
RIM BEAM
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
1
VAPOUR CONTROL
LAYER AS REQUIRED.
REFER TO CM5
PLASTERBOARD
BREATHER
MEMBRANE
Sips Eco Panel
REFER TO CM5
PLASTERBOARD ON
BATTENS. REFER TO
CM510 FOR
SPECIFICATION
95x45 STUD
PLAN
READ IN CONJUNCTION
WITH CM5
HELIFIX TIMTIE 6
OR STAINLESS
STEEL SIMPSON
STRONGTIE
SWT50 TIMBER
FRAME WALL
TIES
JUNCTION OF EXTERNAL
AND INTERNAL WALL
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
2
30
CAVITY BARRIER NAILED
TO JAMB STUDS AND
FITTED WITH DPC
DOOR AND WINDOW FIXED TO
FRAME USING WINDOW
CRAMPS. SPACE CRAMPS AT
600c/c AND EQUAL DISTANCE
FROM ENDS.
CILL
DOOR FRAME SET BACK
30mm FROM EDGE OF
BATTEN.
HELIFIX TIMTIE 6 OR
STAINLESS STEEL
SIMPSON
STRONGTIE SWT50
TIMBER FRAME
WALL TIES AT JAMB
TO BE SPACED AT
225 c/c VERTICALLY
PLASTERBOARD & VCL
CONTINUES AROUND
JAMB. REFER TO CM311
FOR SPECIFICATION
PLAN
BREATHER MEMBRANE
SERVICE VOID
SEALANT
REFER TO CM311 FOR MOVEMENT CONTROL
TIMBER JAMB
DOOR/WINDOW
FIXING 1
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
3
TIMBER WINDOW CILL
TIMBER WINDOW BOARD
D.P.C. DRESSED INTO
RECESS IN FRAME AND
STAPLE FIX TO BATTEN
LAP WITH VCL.
CANT CILL BRICK TO BE
USED WHERE REQUIRED
FOR SHORT CILLS.
30
TIMBER JAMB
CAVITY BARRIER NAILED
TO JAMB STUDS AND
FITTED WITH DPC
PLASTERBOARD & VCL
CONTINUES AROUND
JAMB. REFER TO CM311
FOR SPECIFICATION
SECTION THROUGH WINDOW CILL
WINDOW FIXED TO FRAME
USING WINDOW CRAMPS
NAILED TO BATTENS AND
FRAME. SPACE CRAMPS
AT 600c/c AND EQUAL
DISTANCE FROM ENDS.
ELEVATION
REFER TO CM522 FOR
MOVEMENT CONTROL
.
ALLOWANCE FOR
DIFFERENTIAL
MOVEMENT
TIMBER FRAME LINTOL.
(NOT SUPPLIED-CATNIC
CTF5 OR SIMILAR) USE AS
CAVITY TRAY OR PROVIDE
ONE ABOVE TUCKED
BEHIND BREATHER
MEMBRANE
SEALANT
SEALANT
HELIFIX TIMTIE 6 OR
STAINLESS STEEL TIMBER
FRAME WALL TIES AT
JAMB TO BE SPACED AT
225 c/c VERTICALLY
REFER TO CM311 FOR MOVEMENT CONTROL
SECTION
DOOR/WINDOW
FIXING 2
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
4
SAFETY PRECAUTIONS
UPVC WINDOWS CAN BE VERY HEAVY. LIFTING OF FRAMES TO BE DONE IN THE
APPROPRIATE MANNER AS TO AVOID STRAIN AND RESULTING INJURIES. IF A FRAME IS
HEAVY GET SOMEONE ELSE TO HELP WITH LIFTING IT.
ALWAYS WEAR THICK HAND PROTECTING GLOVES WHEN HANDLING GLASS OR GLAZING
UNITS. BE EXTREMELY CAREFUL WHEN MOVING FRAMES ABOUT.
IF ANY LADDERS ARE USED ENSURE THAT THEY ARE SOUND AND USED PROPERLY AND
SECURELY FASTENED. IF WORKING AT FIRST FLOOR LEVEL & HIGHER THE USE OF STAGING
PLATFORMS IS SAFER THAN LADDERS.
TO PREVENT POSSIBLE ALLERGIC REACTION TO MASTIC WEAR SUITABLE RUBBER GLOVES
WHEN HANDLING OR TOUCHING MASTIC, ALWAYS ADHERE TO MANUFACTURERS
INSTRUCTIONS.
HANDLING OF uPVC FRAMES.
FRAMES TO BE CARRIED AS NEAR TO VERTICAL AS POSSIBLE. THEY SHOULD BE HANDLED
FROM THE ENDS AND AS CLOSE TO THE TOP AS POSSIBLE. THIS IS MOST ESSENTIAL WHEN
THE UNITS ARE READY GLAZED BECAUSE THE EXTRA GLASS WEIGHT WILL GREATER
DEFLECTIONS.
HORIZONTAL LIFTING CAN CREATE SUFFICIENT TWIST IN THE FRAME TO CAUSE GLAZING
SEAL MOVEMENT, AND THUS WATER PENETRATION CAN OCCUR IF THIS IS NOT RECTIFIED
WHEN FIXING. IN THE WORST CASES, WITH LARGE GLAZED WINDOWS, GLASS BREAKAGE
CAN OCCUR BY POOR HANDLING.
IT SHOULD BE NOTED THAT DISTORTION IS NOT A PERMANENT FEATURE OF MISHANDLING
AND CAN BE RECTIFIED SIMPLY DURING THE FIXING OPERATION.
FOR WINDOWS ABOVE GROUND FLOOR LEVEL IT MAY BE NECESSARY TO USE SPECIALIST
LIFTING EQUIPMENT FOR HEAVY FRAMES.
PREPARATION OF THE FRAME.
1. IF FIXING BRACKETS ARE TO BE USED, THEN THESE SHOULD NOW BE FIRMLY ATTACHED
TO THE OUTER FRAME, STARTING NO LESS THAN 150mm MINIMUM FROM THE CORNERS
AND NO MORE THAN 600mm APART.
2. IF IT IS REQUIRED TO SCREW THROUGH THE MAIN OUTER FRAME INTO THE STRUCTURE,
THEN THE GLASS IN THE APPROPRIATE FIXED LIGHTS MUST BE REMOVED. REFER TO
SUPPLIER'S INSTRUCTIONS.
3. IF A SILL IS REQUIRED AND HAD BEEN SUPPLIED SEPARATELY FROM THE WINDOW, THEN
IT MUST NOW BE ATTACHED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS.
IF THE SILL IS TO BE FIXED TO THE WINDOW FRAME WITH SCREWS, ALWAYS SCREW FROM
THE UNDERSIDE OF THE SILL INTO THE FRAME. IT IS IMPORTANT THAT THE FIXING SYSTEMS
DO NOT PENETRATE DRAINAGE CHANNELS. (SEE MANUFACTURERS SEPARATE
INSTRUCTIONS).
4. IF THE WINDOW IS TOO HEAVY FOR CONVENIENT HANDLING, THE GLASS UNITS MAY HAVE
TO BE REMOVED (SEE SUPPLIERS INSTRUCTIONS) OR IN THE CASE OF AN INWARD OPENING
TILT AND TURN WINDOW, IT MAY BE MORE CONVENIENT TO REMOVE THE SASH OR SASHES.
(SEE SUPPLIERS INSTRUCTIONS). ONCE THE SASH HAS BEEN REMOVED, DO NOT ALTER
THE POSITION OF THE OPERATING HANDLE UNTIL THE SASH HAS BEEN REFITTED.
5. STORE ANY GLASS OR SASH YOU HAVE REMOVED SAFELY AWAY FROM WHERE YOU ARE
WORKING.
INSTALLATION OF uPVC
WINDOWS SHEET ONE
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
5
FITTING LOCATING SILL.
1. THE TONGUE OF THE SILL LOCATES IN THE OUTER FRAME GROOVE, THE EXCESS SPRUE
OF THE WELD MUST BE CLEARED OUT SO THE SILL FITS FLUSH WITH THE WINDOW FRAME.
2. A THIN LINE OF SILICON SHOULD BE APPLIED TO THE BOTTOM RAIL OF THE WINDOW
BEFORE THE SILL IS APPLIED.
3. AT THE END OF THE WINDOW AND SILL, SILICON SHOULD BE APPLIED TO BLOCK OFF ANY
WATER PENETRATION CAUSED THROUGH CAPILLARY ACTION. (APPROX. 8mm IN)
4. END CAPS SHOULD NOW BE FITTED USING EITHER CONTACT GLUE OR CONTACT CEMENT.
INSTALLATION.
1. CHECK THAT THE FRAME WILL FIT INTO THE APERTURE. THERE SHOULD BE A MINIMUM
OF 10mm CLEARANCE ON BOTH HEIGHT AND WIDTH, 5mm ALL AROUND THE FRAME. CHECK
THAT THE DPC HAS BEEN INSTALLED & IS NOT DAMAGED.
2. OFFER THE WINDOW INTO THE APERTURE, BEDDING IN THE MANNER RECOMMENDED BY
THE SYSTEM SUPPLIER, TEMPORARILY WEDGING IT INTO POSITION MAKING SURE ITS LEVEL
& PLUMB.
3. FIX THE WINDOW INTO THE APERTURE USING EITHER FIXING BRACKETS OR BY DRILLING
AND SCREWING THE OUTER FRAME, SCREW HOLES SHOULD BE NO LESS THAN 150mm
FROM THE CORNERS AND AT NO MORE THAN 600mm CENTRES. IF IT IS NECESSARY TO
SCREW THROUGH THE BOTTOM MEMBER OF THE OUTER FRAME, (WHERE WATER CAN
COLLECT) THEN ADEQUATE SEALING SHOULD BE APPLIED. IF A FIXING IS REQUIRED ALONG
THE BOTTOM MEMBER IT IS PREFERABLE TO USE BRACKETS.
4. INSERT EXPANDING PLUGS AND SCREW HOME FIRMLY. CHECK BY MEASUREMENT THAT
THE ACTION OF TIGHTENED SCREWS HAS NOT DISTORTED THE FRAME. CHECK THAT ALL
OPENING WINDOWS FUNCTION CORRECTLY AND THE HANDLES DO NOT FOUL THE FRAME.
CHECK THAT THE DRAIN PLUGS ARE NOT DAMAGED OR BLOCKED.
5. REFIT SASH OR SASHES THAT WERE REMOVED.
6. CHECK THE WINDOW FOR CORRECT OPERATION BEFORE PROCEEDING WITH THE MASTIC
SEAL OR MAKING GOOD.
ADJUSTMENT OF HINGES.
NORMALLY THE HINGES ARE ADJUSTED ON GLAZED UNITS BEFORE LEAVING THE FACTORY,
BUT IN SOME CASES ADJUSTMENT ON SITE MAY BE NECESSARY.
THIS IS DONE BY TURNING THE SMALL BRASS ADJUSTING SCREW CLOCKWISE TO INCREASE
THE FRICTION. THIS MUST BE DONE GRADUALLY IN SMALL INCREMENTS AND EVENLY ON
BOTH SIDES TO AVOID TWISTING THE FRAME DURING THE OPERATION.
THE FRICTION SHOULD BE ADJUSTED UNTIL THE OPENING LIGHT WILL REMAIN FIXED IN ANY
OPEN POSITION.
CLEANING OF uPVC WINDOWS
TO KEEP THE WINDOW FRAMES IN GOOD CONDITION THEY SHOULD BE WASHED DOWN
REGULARLY WITH A WEAK HOUSEHOLD DETERGENT SOLUTION. FOR STUBBORN GREASY
STAINS USE A SPOT OF WHITE SPIRIT OR METHYLATED SPIRITS ON A CLEAN CLOTH. IN
DIFFICULT CORNERS AN OLD TOOTHBRUSH OR NAIL BRUSH MAY BE USED.
DO NOT USE ABRASIVE CLEANING POWDERS, WIRE WOOL OR AMMONIA BASED CLEANING
AGENTS.
INSTALLATION OF uPVC
WINDOWS SHEET TWO
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
6
EFFECTIVE EDGE SEALING TO PARTY WALLS
THE CURRENT BUILDING REGULATIONS UNDER APPROVE DOCUMENT L
REQUIRES THAT THE CAVITY IS SEALED AND THAT THE SEALING IS
EFFECTIVE AT RESTRICTING AIR FLOW AND ALSO ALIGNED WITH THE
THERMAL ENVELOPE. IT WILL ALSO BE NECESSARY TO DEMONSTRATE
THAT THE DESIGN ADOPTED IS LIKELY TO BE ROBUST UNDER NORMAL
SITE CONDITIONS. THE EDGE OF THE PARTY WALL CAVITY SHOULD BE
CLOSED WITH A MINERAL WOOL BATT AND POLYTHENE SLEEVED MINERAL
WOOL CAVITY BARRIERS TO EITHER SIDE OF THE PARTY WALL IN THE
EXTERNAL WALL CAVITY. REFER TO DETAIL ON SHEET E5. THE DETAIL ON
THE FOLLOWING SHEETS CM217.2 AND CM217.3 SHOWS A REASONABLY
ROBUST LEVEL OF SEALING.
AT THE JUNCTION OF THE PARTY WALL AND EXTERNAL WALL CAVITY, THE
EDGE OF THE PARTY WALL IS STOPPED WITH EITHER WIRE
REINFORCED MINERAL WOOL, OR A POLYTHENE SLEEVED MINERAL
WOOL CAVITY BARRIER. TYPICALLY ONE WIDE OR TWO NARROW CAVITY
BARRIERS ARE INSTALLED IN THE EXTERNAL WALL CAVITY EITHER SIDE
OF THE PARTY WALL CAVITY. THESE ARRANGEMENTS OF CAVITY
BARRIERS FIRMLY COMPRESSED AND FITTED CORRECTLY SHOULD ALSO
ADD TO THE ROBUSTNESS AND EFFECTIVENESS OF THE AIR SEAL.
THE TOP AND BOTTOM OF THE PARTY WALL CAVITIES CAN ALSO BE
CLOSED USING A SIMILAR ARRANGEMENT OF AIR BARRIERS. ONCE THE
GROUND FLOOR SOLE PLATES ARE LAID, A 300 MM WIDE STRIP OF AIR
BARRIER CAN BE PLACED OVER THE SOLE PLATES AND PARTY WALL
CAVITY BEFORE THE PARTY WALL PANELS ARE ERECTED. THIS AIR
BARRIER CAN ALSO BE EXTENDED OUT PAST THE END OF THE PARTY
WALL, RETURNED UP THE FACE OF THE EXTERNAL WALL AND LAPPED
AND SEALED TO THE EXTERNAL WALL BREATHER MEMBRANE OR AIR
BARRIER ENSURING ALL LAPS DEFLECT MOISTURE AWAY FROM THE
SIPS FRAME AT THE TOP OF THE PARTY WALL (EITHER AT EACH FLOOR
ZONE, OR AT TOP FLOOR CEILING LEVEL) A SIMILAR ARRANGEMENT OF
AIR BARRIERS COULD BE INSTALLED BEFORE THE SPANDREL PANELS ARE
ERECTED. ANY JOINTS IN THE AIR BARRIERS SHOULD BE LAPPED, TAPED
AND WHERE POSSIBLE MECHANICALLY FIXED.
1
2
3
PARTY WALL
EDGE SEALING DETAIL 1
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
7.1
PART E 15.9.11
EXTERNAL
SIP PANEL
HIGH PERFORMANCE BREATHER
MEMBRANE LAP LEFT LOOSE
SOLEPLATE
SLAB
AIR
BARRIER
1
2
PARTY WALL
EDGE SEALING DETAIL 2
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
7.2
PART E 15.9.11
BREATHER
MEMBRANE
ON SIP PANEL
BREATHER
MEMBRANE LAPPED AND SEALED
WITH PROPRIETARY TAPE
AIR BARRIER RETURNED UP THE OUTER
FACE OF FRAME BEFORE BREATHER
MEMBRANE IS LAPPED AND SEALED
WITH PROPRIETARY TAPE
3
PARTY WALL
EDGE SEALING DETAIL 3
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
7.3
BOTTOM RAIL
TOP RAIL
SIP LINTEL
ELEVATION
1020
SIP
PANELS
LINTEL
THE INNER TIMBER ON BOTH
SIDES IS TO BE LEFT ON SITE
AND NOT FIXED. THIS IS FOR
CLIENT'S USE IF TIMBER DOOR
FRAMES ARE USED. THEY ARE
OMITTED IF uPVC DOOR FRAME
IS USED. THEY ARE NOT
SUPPLIED FOR OTHER DOORS.
PAS90 NAILS
FIXING 45 x95
TO 45x120 @
200 c/c
35mm SCREWS FIXING PANELS TO TOP
AND BOTTOM PATES & REBATED
CRIPPLE STUDS @ 150mm c/c (STARTING
50mm IN FROM EACH END)
EXTERNAL SINGLE
DOOR OPENING
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
8
TREATED BATTENS FIXED TO PANEL
USING 3mm WOODSCREWS AT
600mm c/c
BREATHER MEMBRANE
BOARD JOINTS MUST
OCCUR AT BATTENS
MIN. OVERLAP 25mm
WEATHER BOARDING CAN BE APPLIED TO EXTERNAL MASONRY SKIN OF A
CAVITY WALL OR AS SHOWN ABOVE FOR SINGLE OR TWO STOREY
CONSTRUCTION.
ADDITIONAL COUNTER BATTENS MAY BE NECESSARY BETWEEN THE
VERTICAL BATTENS AND THE BREATHER MEMBRANE IN SEVERELY EXPOSED
AREAS TO PERMIT MORE EFFICIENT DRAINAGE OF ANY WATER.
ADDITIONAL BATTEN MAY ALSO BE REQUIRED TO ALLOW CLADDING TO LINE
THROUGH WITH BRICKWORK BELOW.
TO AVOID INFESTATION BY INSECTS, OPENINGS TO THE CAVITY SHOULD BE
PROTECTED BY AN INSECT SCREEN.
HORIZONTAL BATTENS, IF
REQUIRED, SHOULD PROVIDE
FOR VENTILATION AND
DRAINAGE. TOPS OF BATTENS
SHOULD ALSO SLOPE TOWARDS
THE OUTSIDE.
3mm SS WOODSCREWS AT
600mm c/c
CLADDING - TIMBER
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
21
9
BREATHER
MEMBRANE
DPC
BACKED METAL LATHE
CEMENT RENDER USUALLY IN
THREE COATS
DRAINED AND VENTILATED
CAVITY
TREATED BATTENS FIXED TO
PANEL USING 3mm SS
WOODSCREWS AT 600mm c/c.
HORIZONTAL BATTENS SHOULD
PROVIDE FOR VENTILATION AND
DRAINAGE. TOPS OF BATTENS
SHOULD ALSO SLOPE TOWARDS
THE OUTSIDE.
RENDER CAN BE APPLIED TO EXTERNAL MASONRY SKIN OF A CAVITY WALL
OR AS SHOWN ABOVE FOR SINGLE OR TWO STOREY CONSTRUCTION.
BATTENS TO BE MINIMUM 50mm UNLESS BUILDING PAPER BACKED
LATHE IS USED, IN WHICH CASE BATTENS MAY BE REDUCED TO 25mm.
ADDITIONAL HORIZONTAL COUNTER BATTENS MAY BE NECESSARY
BETWEEN THE VERTICAL BATTENS AND THE BREATHER MEMBRANE
IN SEVERELY EXPOSED AREAS TO PERMIT MORE EFFICIENT
DRAINAGE OF ANY WATER.
ADDITIONAL BATTEN MAY ALSO BE REQUIRED TO ALLOW CLADDING TO LINE
THROUGH WITH BRICKWORK BELOW.
TO AVOID INFESTATION BY INSECTS, OPENINGS TO THE CAVITY SHOULD BE
PROTECTED BY AN INSECT SCREEN.
CLADDING - RENDER
SHEET 1
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
22
0
TREATED BATTENS FIXED TO PANEL
PROTECTED BY INSECT SCREEN.
HORIZONTAL BATTENS SHOULD
PROVIDE FOR VENTILATION AND
DRAINAGE. TOPS OF BATTENS
SHOULD ALSO SLOPE TOWARDS
THE OUTSIDE.
PROPRIETARY INTUMESCENT STRIP
WITH DRAINAGE AND VENTILATION
GRID
PROPRIETARY METAL RENDER
STOPS
MOVEMENT JOINT.
REFER TO CM32
POLYTHENE DPC TO
FACE OF BATTENS
AND DRESSED UP
BEHIND BREATHER
MEMBRANE
3mm SS
WOODSCREWS
AT 600mm c/c
CLADDING - RENDER
ALLOWANCE FOR
MOVEMENT
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
22
1
TREATED BATTENS FIXED TO
PANEL. VERTICAL BATTENS
SHOULD PROVIDE FOR
VENTILATION AND DRAINAGE IF
REQUIRED. TOPS OF BATTENS
SHOULD ALSO SLOPE TOWARDS
THE OUTSIDE.
25mm BATTENS FIXED WITH 3mm
SS WOODSCREWS AT 600mm c/c
12mm COUNTER BATTENS FIXED
WITH 3mm SS WOODSCREWS AT
600mm c/c IF REQUIRED.
BREATHER MEMBRANE
PLAIN TILES
TILE HANGING CAN BE APPLIED TO EXTERNAL MASONRY SKIN
OF A CAVITY WALL OR AS SHOWN ABOVE FOR SINGLE OR TWO
STOREY CONSTRUCTION.
ADDITIONAL VERTICAL COUNTER BATTENS MAY BE NECESSARY
BETWEEN THE HORIZONTAL BATTENS AND THE BREATHER MEMBRANE
IN SEVERELY EXPOSED AREAS TO PERMIT MORE EFFICIENT DRAINAGE
OF ANY WATER.
ADDITIONAL BATTEN MAY ALSO BE REQUIRED TO ALLOW CLADDING
TO LINE THROUGH WITH BRICKWORK BELOW.
TO AVOID INFESTATION BY INSECTS, OPENINGS TO THE CAVITY
SHOULD BE PROTECTED BY AN INSECT SCREEN.
CLADDING -
TILE HANGING
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
22
2
WALL TIE
Sips Eco Panel
PLASTERBOARD
ON BATTENS
VAPOUR CONTROL
LAYER
Sips Eco Panel
BREATHER
MEMBRANE
PLAN
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS
OMITTED FOR CLARITY. REFER TO CM510 FOR SPECIFICATION
EXTERNAL WALL
CORNER
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
22
3
4
5
4
5
FIXING OF
PLASTERBOARD
CEILING
NOGGINGS AT
ALL JOINTS AT
600mm c/c
PANEL TO PANEL JUNCTION
INSULATED SPLINE JOINING 2
PANELS TOGETHER. THIS
COULD ALSO BE SOLID
TIMBER. FIXED USING 35mm
SCREWS @ 150mm c/c
(STARTING 50mm FROM END
OF PANEL)
PLASTERBOARD. REFER TO
CM510 FOR SPECIFICATION
NOGGINGS AND PANEL
CONNECTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
31
0
SOFTWOOD BATTENS AT 600mm c/c
ON VAPOUR BARRIER ON Sips Eco
Panel. IDEAL SIZE FOR BATTENS IS
25mm x 25mm BUT THEY CAN BE
SMALLER SUBJECT TO FIRST FIX
SERVICES.
SERVICE VOID
FOR ELECTRICS
AND PLUMBING
PLASTERBOARD
SEE CM510
VAPOUR BARRIER
V.C.L. SEE CM5
PLASTERBOARD
FIXING DETAIL
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
31
1
22mm CHIPBOARD FLOOR (WEYROC
PROTECT OR SIMILAR TO ACHIEVE
15kg/m2) DECKING ON TJI OR ULTRA
JOISTS AT MAXIMUM 600mm c/c.
100mm GLASSFIBRE
INSULATION QUILT. [ISOVER
APR 1200 OR SIMILAR
APPROVED]. HUNG USING
NETTING IF REQUIRED.
15mm PLASTERBOARD. REFER
TO CM510 FOR SPECIFICATION
IT IS POSSIBLE TO DRILL HOLES THROUGH THE TJI FLOOR JOISTS BUT
APPROVAL MUST BE GIVEN BY Sips Eco Panels. GENERALLY A HOLE OF UP TO
38mm CAN BE DRILLED ANYWHERE IN THE WEB, HOWEVER THERE SHOULD BE
A GAP OF AT LEAST 2 x DIAMETER OF LARGEST HOLE BETWEEN HOLES. ANY
HOLES BIGGER THAN 38mm MUST BE APPROVED BY Sips Eco Panels.
MID FLOOR
SOUND INSULATION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
31
2
BUILDING REGULATIONS PART E - RESISTANCE TO THE PASSAGE OF SOUND
DWELLING HOUSES SHALL BE DESIGNED AND CONSTRUCTED SO THAT
INTERNAL ROOMS BETWEEN BEDROOMS OR A ROOM CONTAINING A WATER
CLOSET [W.C.] AND OTHER ROOMS AND INTERNAL FLOORS PROVIDE
REASONABLE RESISTANCE TO THE PASSAGE OF SOUND.
HOWEVER, THIS DOES NOT APPLY TO WALLS CONTAINING A DOOR OR WALLS
SEPARATING AN EN-SUITE TOILET FROM AN ASSOCIATED BEDROOM.
25mm ISOWOOL ACOUSTIC PARTITION ROLL [1200] IN
THE CAVITY
15mm KNAUF SOUND PANEL (10kg/m²)
45mm x 95mm STUDS AT 600mm c/c NOMINALLY
THESE DETAILS ARE FOR A WALL
SEPARATING A ROOM WITH A W.C. OR
A BEDROOM FROM ANOTHER ROOM.
15mm KNAUF SOUND PANEL (10kg/m²)
SOUND INSULATION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
31
3
HEAD BINDER
TOP RAIL
PLASTERBOARD
SOUND INSULATION
BATTEN
BOTTOM RAIL
LOCATOR PLATE IF
SPECIFIED
PLASTERBOARD
SKIRTING BOARD
FLOOR DECKING
I-BEAM
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS
OMITTED FOR CLARITY. REFER TO CM510 FOR SPECIFICATION.
INTERNAL WALL
RUNNING ACROSS
FLOOR JOISTS
SPAN
JUNCTION OF INTERNAL
LOAD BEARING WALL
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
31
4
STUD
PLASTERBOARD
NOGGINGS
PLAN
READ IN CONJUNCTION WITH CM510. REFER TO CM510 FOR
PLASTERBOARD SPECIFICATION.
15mm PLASTERBOARD
FIXED USING SMOOTH
SHANK GALVANISED
FLAT ROUND HEAD
NAILS AT 150mm c/c OR
SCREWS AT 230mm c/c
INTERNAL WALL
TO WALL JUNCTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
31
5
HEAD BINDER
TOP RAIL
PLASTERBOARD
SOUND
INSULATION
BOTTOM RAIL
LOCATOR PLATE IF
SPECIFIED
PLASTERBOARD
SKIRTING BOARD
FLOOR DECKING
I-BEAM
SPAN
READ IN CONJUNCTION WITH CM5. REFER TO CM311 AND
CM510 FOR PLASTERBOARD SPECIFICATION.
PLASTERBOARD
NON LOADBEARING
WALL AND FLOOR
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
31
6
STUD CLUSTER
PLASTERBOARD
STUD
PLAN
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS OMITTED FOR
CLARITY. REFER TO CM311 AND 510 FOR PLASTERBOARD SPECIFICATION.
INTERNAL WALLS
JUNCTION IN
FOUR DIRECTIONS
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
31
7
SKIRTING BOARD
FLOOR DECKING
I-JOIST
PLASTERBOARD
SOUND
INSULATION
PLASTERBOARD
HEAD BINDER
TOP RAIL
BOTTOM RAIL
LOCATOR PLATE IF
SPECIFIED
NOGGING
NOGGING OR
BLOCKING
ACCORDING TO
CALCULATED
DEFLECTION
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS OMITTED
FOR CLARITY. REFER TO CM311 AND 510 FOR PLASTERBOARD
SPECIFICATION.
NON LOAD BEARING
WALL PARALLEL
TO JOISTSIS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
31
8
FASCIA AND SOFFIT
SUPPORT MADE UP ON
SITE TO SUIT DESIGN OR
SUPPLIED WITHIN SIP
PANEL.
ROOF TILES ON ROOFING
BATTENS ON 25mm
COUNTER BATTENS ON
BREATHER MEMBRANE
ON SIP ROOF PANEL
TILTING FILLET
END BLOCK
CAVITY CLOSER
SOFFIT
FASCIA
DIFFERENTIAL MOVEMENT
JOINT REFER TO CM522
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS OMITTED FOR CLARITY. REFER
TO CM311 & 510 FOR PLASTERBOARD SPECIFICATION.
CLOSED EAVES
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
41
0
FASCIA AND SOFFIT
SUPPORT MADE UP ON
SITE TO SUIT DESIGN
CAVITY CLOSER
WINDOW FRAME. DOOR
FRAME DETAIL SIMILAR
DIFFERENTIAL MOVEMENT
JOINT REFER TO CM522
25mm
COUNTER
BATTEN
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS
OMITTED FOR CLARITY. SEE ALSO CM410. REFER TO CM311 &
510 FOR PLASTERBOARD SPECIFICATION.
CLOSED EAVES
AT WINDOW HEAD
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
41
1
TILTING FILLET
END BLOCK
25mm
COUNTER
BATTEN
SOFFIT PLY TO SUIT
READ IN CONJUNCTION WITH CM5 AND CM410.
PLASTERBOARD DETAILS OMITTED FOR CLARITY.
REFER TO CM311 & 510 FOR PLASTERBOARD
SPECIFICATION.
FLUSH EAVES
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
41
2
TILTING FILLET
END BLOCK
CAVITY CLOSER
25mm COUNTER
BATTEN
SOFFIT PLY TO SUIT
READ IN CONJUNCTION WITH CM5 AND CM40. PLASTERBOARD
DETAILS OMITTED FOR CLARITY. REFER TO CM311 FOR
PLASTERBOARD SPECIFICATION.
DPC
OPEN EAVES
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
41
3
DOWNSTAND BEAM TO
SUPPORT SIPS PANELS TO
ENGINEER'S
SPECIFICATIONS.
INFILL WEDGE
READ IN CONJUNCTION WITH CM5 AND CM410. PLASTERBOARD
DETAILS OMITTED FOR CLARITY. REFER TO CM510 FOR
PLASTERBOARD SPECIFICATION.
TYPICAL EAVES
(ATTIC ROOM)
VCL
READ IN CONJUNCTION WITH CM5. PLASTERBOARD
DETAILS OMITTED FOR CLARITY. REFER TO CM311 &
510 FOR PLASTERBOARD SPECIFICATION.
ENSURE VCL IS CONTINUOUS
TO RETAIN INTEGRITY OF
BUILDING SHELL
TYPICAL RIDGE AND
ATTIC ROOM DETAIL
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
41
4
4
5
45mm x172mm x 2 TIMBER SPLINES
JOINING 2 PANELS TOGETHER.
FIXED AS SHOWN BELOW
50
8.0 x 80mm WASHERHEAD SCREW
SIMPSON STRONG TIE CODE ESCR8.0x80
OR 6.0x95 HEADLOK @ 600mm c/c (BOTH
SIDES - STAGGERED).
3.5 x 35mm COARSE THREAD DRYWALL
SCREWS @ 150mm c/c.
3.1 x 90mm SMOOTH GALVANISED
NAILS AT 300mm c/c (ONE SIDE).
50
C
L
1
5
0
3
0
0
3
0
0
3
0
0
3
0
0
3
0
0
3
0
0
3
0
0
3
0
0
6
0
0
6
0
0
6
0
0
TIMBER SPLINES PROJECT
BEYOND PANEL AND CUT PLUMB
ON SITE BY OTHERS
THIS DETAIL IS USED IF 90mm SPLINES ARE NOT PROVIDED.
ROOF PANEL TO PANEL
CONNECTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
41
4
DETACHED HOUSE
EXTERNAL WALLS
Sips Eco Panel - 15mm KNAUF SOUND PANEL ON 10-25mm BATTENS USING 3mm WOOD SCREWS
AT 600mm c/c TO CREATE SERVICE VOID . IN KITCHENS OR WHERE HEAVY OBJECTS ARE TO BE
FITTED IT IS RECOMMENDED 100mm HORIZONTAL BATTENS ARE GLUED AND SCREWED
BETWEEN VERTICALS WHERE REQUIRED.
INTERNAL WALLS
95mm x 45mm TIMBER STUDS AT 600mm c/c. PROVIDE NOGGINGS MID HEIGHT TO SUPPORT ONE
LAYER 15mm KNAUF SOUNDSHIELD PLUS TO BOTH SIDES. OUTER LAYER WALLBOARD JOINTS TO
BE FILLED AND REINFORCED WITH KNAUF TAPE AND JOINT.
FLOORS
PLYWEB JOISTS, SOLID JOISTS OR METAL WEB JOISTS PROVIDE 1 LAYER OF 15mm KNAUF
WALLBOARD.
FLATS, SEMI-DETACHED AND TERRACED HOUSES.
PARTY WALLS
2 LAYERS OF KNAUF WALLBOARD WITH ALL JOINTS STAGGERED
LOADBEARING WALL 60 MINUTES
2 LAYERS OF KNAUF FIRE PANEL EACH SIDE WITH ALL JOINTS STAGGERED ON OPPOSITE SIDES
AND EACH LAYER WITH JOINTS FILLED AND REINFORCED WITH KNAUF TAPE AND JOINT.
FLATS
EXTERNAL WALLS
2 LAYERS OF 15mm KNAUF FIRE PANEL. ALL PLASTERBOARD JOINTS SHOULD BE STAGGERED
WITH JOINTS FILLED AND REINFORCED WITH KNAUF TAPE AND JOINT.
COMPARTMENT FLOORS
PLYWEB OR METAL WEB JOISTS PROVIDE 2 LAYERS OF 15mm KNAUF WALLBOARD.
SOLID JOISTS PROVIDE 2 LAYERS OF 15mm KNAUF SOUND PANEL (10kg/m²) ON BR1 GYPFRAME
RESILIENT BARS AT MAXIMUM 450mm c/c.
GENERAL NOTES AND NAILING SPECIFICATION
WHERE 2 LAYERS OF PLASTERBOARD ARE REQUIRED JOINTS SHOULD BE STAGGERED.
EACH LAYER OF PLASTERBOARD MUST BE FIXED SEPARATELY AT 150mm c/c TO EACH
STUD AND TOP AND BOTTOM RAIL (IF INTERNAL STUD WALL) AND 150mm c/c TO SIP
PANELS.
BOARDS SHOULD BE FIXED USING DRYWALL HIGH THREAD SCREWS. USE 38mm SCREWS
FOR SINGLE LAYERS AND 63mm SCREWS FOR DOUBLE LAYERS.
LOCATE SCREWS AT LEAST 10mm FROM PAPER BOUND EDGE, 13mm FROM CUT EDGES
AND AT LEAST 6mm FROM EDGE OF TIMBER FRAMING.
PLASTERBOARD
SPECIFICATION
IS
SU
E 9
2014
CM
51
0
20
40
S
TR
UC
TU
RA
L O
PE
NIN
G
FO
R 1
98
1 D
OO
R S
ET
DOOR LINING
DOOR STOP
1-3
mm
32
mm
2m
m
PACK BETWEEN
LINING AND JAMB AT
FIXING POSITIONS.
1-3mm
1-3
TYPICALLY 838 OR 762 DOOR LEAF
1-3
32
1-3
PACK BETWEEN LINING AND
JAMB AT FIXING POSITIONS.
ELEVATION
PLAN
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS
OMITTED FOR CLARITY. REFER TO CM311 & 510 FOR
PLASTERBOARD SPECIFICATION.
32
DOOR
TYPICAL DOOR
OPENING AS ERECTED
TIMBER SUPPLIED
LOOSE. FIT TO SUIT
DOOR OPENING
FR
OM
F
IN
IS
HE
D F
LO
OR
L
EV
EL
INTERNAL
DOOR LINING
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
51
1
CAVITY TRAY/DPC
POSITIONED ABOVE
METER BOX AND
EXTENDED 150mm PAST
JAMBS
BRICK CLADDING
SUPPORTED ON 25mm x
5mm GALVANISED MILD
STEEL BAR
METER BOX TO BE
PLUGGED AND SCREWED
TO BRICKWORK
THROUGH PRE
DETERMINED HOLES.
SIP PANEL
OPEN PERPENDS FOR
DRAINAGE OF CAVITY
STANDARD METER BOX
AS SUPPLIED BY
STATUTORY
AUTHORITIES BEDDED
ON MASTIC
GAS INLET PIPE
ELECTRICITY SUPPLY
FROM METER TO
CONSUMER UNIT. RUN
DOWN CAVITY OR PASS
THROUGH SIP PANEL.
LEAVE AIR GAP BETWEEN
BACK OF BOX AND
BREATHER PAPER.
CAVITY BARRIERS AT
TOP AND SIDES TO
ISOLATE CAVITY
OPENING
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS
OMITTED FOR CLARITY. REFER TO CM311 & 510 FOR
PLASTERBOARD SPECIFICATION.
CAVITY BARRIERS
REQUIRED FOR ALL
METERS
METER BOX
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
51
2
LINE FLUE OUTLET WITH
12mm SUPERLUX OR
SIMILAR FIRE RETARDANT
BOARD AND MAINTAIN A
MIN. 25mm GAP
AREA OF WALL BEHIND BOILER
TO BE LINED WITH 12mm
SUPERLUX OR SIMILAR
NON-COMBUSTIBLE LINING
COMPRESSIBLE MASTIC SEAL
OPEN PERPENDS FOR
DRAINAGE OF CAVITY
EITHER SIDE OF OPENING
GAS FIRED FLUE
[INDICATIVE ONLY]
GAP TO ALLOW FOR
DIFFERENTIAL MOVEMENT.
REFER TO CM522
READ IN CONJUNCTION WITH CM5.
PLASTERBOARD DETAILS OMITTED FOR
CLARITY. REFER TO CM311 & 510 FOR
PLASTERBOARD SPECIFICATION.
ALWAYS CHECK WITH MANUFACTURER
BEFORE INSTALLATION OF FLUE.
WATER DRIP COLLAR
AROUND FLUE
1000 MICRON POLYTHENE
FLASHING OVER BATTENS
ANGLED TO DIRECT MOISTURE
AWAY FROM FLUE AND TO
EXTEND 150mm EACH SIDE OF
FLUE TERMINAL
25
50
NOT LESS
THAN
NON-COMBUSTIBLE FLANGE
COMPRESSIBLE
MASTIC SEAL
WATER DRIP COLLAR
AROUND FLUE
NON-COMBUSTIBLE LINING
BEHIND BOILER WHERE
APPROPRIATE
25
NON-COMBUSTIBLE SLEEVE
(EXTEND TO FORM CAVITY
BARRIER AROUND OPENING,
OR INSERT SEPARATE TOP AND
VERTICAL CAVITY BARRIERS TO
ISOLATE CAVITY OPENING
FLUE DETAIL
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
51
3
s
e
c
t
i
o
n
SECTION
MIN. 25mm
FRONT VIEW
OPENING IN WALL FOR BOILER FLUE
CAN BE CUT TO SUIT ON SITE BUT
MUST BE AGREED WITH CUSTOM
HOMES BEFORE CUTTING. IDEALLY
HOLE SHOULD BE POSITIONED
CENTRALLY TO PANEL BUT MUST BE AT
LEAST 500mm FROM TOP OF PANEL
IF A BOILER IS TO BE WALL MOUNTED
THEN IT SHOULD BE FITTED IN
ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS.THE BOILER SHOULD BE
FITTED USING FULLY THREADED
SCREWS/NAILS. THE OPENING SHOULD
BE CUT AND THE INSULATION RAKED
OUT USING A HOT WIRE ROUTER TO
ALLOW THE HOLE TO BE TRIMMED
USING 44mm x (INTERNAL PANEL
WIDTH) STUDS. THESE SHOULD BE
NAILED THROUGH THE OSB AT 50mm
c/c. THE FLUE SHOULD HAVE A MINIMUM
GAP ALL ROUND THE OUTSIDE OF THE
FLUE.
IF THE APPLIANCE IS NOT SUITABLE
FOR MOUNTING DIRECTLY ONTO A
WALL PANEL IT SHOULD BE SEPARATED
BY A 75mm GAP OR AN ADDITIONAL
LAYER OF PLASTERBOARD [25mm
TOTAL].
READ IN CONJUNCTION WITH CM5.
PLASTERBOARD DETAILS OMITTED
FOR CLARITY. REFER TO CM311 & 510 FOR
PLASTERBOARD SPECIFICATION.
WALL HUNG BOILER
FLUE
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
51
4
1340min x 1500mm
HOLE LEFT IN SIP
PANEL
GAP BETWEEN TIMBER
FRAME AND MASONRY TO
BE FILLED WITH MINERAL
WOOL
TIMBER LINTEL TO BE
AT LEAST 300mm
FROM INNER FACE OF
FLUE RECESS.
AT LEAST 40mm AIR
SPACE IF WALL OF
CHIMNEY IS LESS
THAN 200mm
HEARTH TO BE AT
LEAST 125mm THICK
PROJECTING 500mm
40mm GAP FILLED
WITH MINERAL WOOL
BETWEEN PANEL AND
BRICKWORK
PLAN ON CHIMNEY RECESS
PLAN ON CHIMNEY AT
UPPER FLOOR LEVEL
AT LEAST 40mm AIR
SPACE IF WALL OF
CHIMNEY IS LESS
THAN 200mm
FIL VOID AROUND
FLUE WITH WEAK
SAND/CEMENT FILL
340MIN.
450 MIN.
13
40
M
IN
.
20
0 M
IN
.
440 MIN.
44
0 M
IN
.
SIP PANEL - DETAIL
OMITTED FOR
CLARITY
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS OMITTED
FOR CLARITY. REFER TO CM311 & 510 FOR PLASTERBOARD
SPECIFICATION.
CHIMNEY DETAILS
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
51
5
CONSTRUCTION
HEARTH
300
MIN
SUPERIMPOSED HEARTH
cm. / SAND SCEED
BS 1251 PCC LINTEL OR
HOOD UNIT
25mm WIDE
NON-COMBUSTIBLE TAPE
FORMING EXPANSION JOINT
FIREPLACE SURROUND TO
BD 1251 FIXED TO WALL
WITH SCREWS THROUGH
CAST-IN FIXING LUGS
REBATED FLUE LINERS TO BS
1181
SQUARE LINED FLUE OF SOLID
NON-COMBUSTIBLE BLOCKS
OR BRICKS
1
0
0
EXTERNAL WALL
THROAT
FLUE GATHERING
BS 1251 FIREBACK
1:2:4 LIME: SAND:
BROKEN BRICK
FILLING
CORRUGATED PAPER
LINING TO FORM AN
EXPANSION JOINT
GROUND LEVEL APPROX.
DPC
GROUND FLOOR
12
5 M
IN
500 MIN
CHIMNEY SECTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
51
6
b1
b1
a1a1
100
200
200
100
c1
c1
WATER TANK 227L NOM. MAX.
cc
b
b
aa
300
300
300
150
150
150
150
WATER TANK SPACED
CENTRALLY
WATER TANK 295L NOM. MAX.
cc
b
aa
CHECK LOCATION AND LOADING WITH STRUCTURAL ENGINEER.
SIZES FOR TANK STAND MATERIALS
a = 40x90 x 2000 LONG
a1 = 40x90 x 1000 LONG
b = 2/40x140 x 300 LONG FOR TRUSSES UP TO 9M SPAN
b1 = 2/40x90 x 4000 LONG FOR TRUSSES UP TO 12M SPAN
c = 40x90 x 1500 LONG
c1 = 40 x 90 x 1000 LONG
15.5x1200x2400 PLYWOOD DECK CUT TO SUIT ON SITE
ALL TANK STAND MATERIAL NAILED WITH 90x4 RUSTPROOF PLAIN HEAD
WATER TANK SUPPORT
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
51
7
h
0.25h
150 m
in
Max. 0.25 stud width
Drilling on centre line only. Hole
diameter not greater than 0.25 stud
width and hole centres not closer than
4d (d = hole diameter).
A hole within these rules in a stud which is at least 89mm deep will generally ensure that pipes or
cables are clear of the 40mm or 50mm long nails normally used to fix 12.5mm or 2 x 12.5mm
plasterboard linings respectively. If other board thickness length combinations are specified, the
risk of damage to the services should be checked. Refer to CM510 for plasterboard specification.
Where there is risk to services from nails or screws used to fix lining or flooring boards,
proprietary steel protection plates should be fixed to bridge the notch and protect the services. If
holes or notches larger than 25% of stud depth are necessary, double studs may be needed at
these positions to offset the effect of cutting away the cross sectional area. Where such holes or
notches occur in load bearing walls, the modified members should be checked by calculation.
Roof rafters and purlins, trusses, trussed rafters or bracing should never be notched or cut away
without the relevant calculations being checked or approval obtained from the structural engineer
or specialist component supplier.
When drilling or notching is carried out by the electrician or plumber as part of their installation
work, it is essential that they are aware of the above limits.
0.25h
150 m
in
Note:
It is recommended to fix Expamet
Safeplates or similar to face of studs
and rails to protect pipes and wires
against rail penetration.
stud height
DRILLING HOLES
IN WALLS
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
52
1
15mm at bottom of opening at
second floor level
9mm at bottom of opening at first
floor level
3mm at bottom of opening at
ground floor level
Note: When a timber suspended
floor is used add 6mm to the
differential movement allowances
quoted.
Allowance at eaves and verge:
17mm - three storey
15mm - two storey
8mm - single storey
Allow for settlement at flashings to
chimneys etc. depending upon the
number of storeys and chimney
placement within the roof span
Note: The allowances shown are for cross sectional timber in the floor zone of conventional platform frame as shown in the detail above,
with timber installed at 20% moisture content and drying to 10% moisture content in service. However, there is minimal shrinkage with
SIPs but allowance should still be allowed for.
The bigger proportion of the differential shrinkage occurs in the floor joists. The shrinkage in the rails and binders does not normally
affect internal linings or the sheathing to panels. However, plasterboard lining to staircase openings of two or more storeys can be
affected since it crosses the floor joist zone. A movement gap in the plasterboard with a cover strip should be provided at the floor zone.
In all cases, the movement gap allowance is for a clear gap. If compressible seals are installed in the gap, the allowance should be
increased as the seal cannot be compressed to zero.
ALLOWANCE FOR VERTICAL
SHRINKAGE WHEN USING
MASONRY CONSTRUCTIONIS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
52
2
Minimum of 4 x 2 woodscrews
2 x 8 (3mm diameter) should be
used to fix this object to the wall
A heavy object such as a
boiler attached to the wall.
100kg x 1000mm x 250mm
Minimum of 6 x 2 woodscrews
2 x 8 (3mm diameter) should be
used to fix the bracket to the wall.
A heavy object resting on a
cantilevered bracket attached to
the wall. 100kg x 250mm x 250mm
15mm plasterboard and
possibly additional
plywood to spread load
15mm plasterboard and
possibly additional
plywood to spread load
SUPPORT TO
HEAVY OBJECT
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
52
3
STATUTORY PROTECTION
TREES MAY BE PROTECTED BY A TREE PRESERVATION ORDER [TPO] OR BY
BEING LOCATED IN A CONSERVATION AREA. FAILURE TO NOTIFY OR OBTAIN
CONSENT FROM THE LOCAL PLANNING AUTHORITY COULD RESULT IN
PROSECUTION. CONDITIONS ATTACHED TO A PLANNING CONSENT MAY ALSO
GIVE PROTECTION TO SPECIFIC TREES.
SITE PROTECTION
PROTECTIVE FENCING SHOULD BE ERECTED AROUND ALL TREES AND HEDGING
TO BE RETAINED ON THE SITE ENCLOSING ALL THE AREA UP TO ONE METRE
BEYOND THE CANOPY SPREAD OF THE TREE. THIS WOULD NORMALLY BE AT
LEAST 1.2M HIGH CLEFT CHESTNUT FENCING ON A FIRM STRONG FRAME WORK
COMPLYING WITH BRITISH STANDARD BS 5837:2005, BS1722 AND ANY PLANNING
CONDITION RELATING TO THE SITE.
TREE PROTECTION ZONE
WITHIN THIS AREA NO ACTIVITY SHOULD TAKE PLACE UNLESS IT HAS BEEN
SPECIFICALLY AUTHORISED IN WRITING FROM THE LOCAL PLANNING
AUTHORITY.
SERVICES AND SOAKAWAYS
ALL SERVICE ROUTES SHOULD BE LOCATED OUTSIDE THE TREE PROTECTION
ZONE. HOWEVER, WHERE SERVICES HAVE TO BE LOCATED IN THE VICINITY OF
TREE ROOTS THEN TRENCHES SHOULD BE DUG BY HAND OR THRUST BORED TO
AVOID SEVERANCE OF FEEDER OR STRUCTURAL ROOTS. ALL SUCH WORK
SHOULD BE CARRIED OUT IN ACCORDANCE WITH N.J.U.G.10 [see opposite] AND
AUTHORISED BY THE LOCAL PLANNING AUTHORITY
TREE SURGERY
TREE SURGERY MAY BE NECESSARY TO ENSURE ALL TREES ARE LEFT IN A
SAFE, HEALTHY CONDITION. A QUALIFIED ARBORIST SHOULD BE APPOINTED TO
SURVEY THE TREES AND CARRY OUT REMEDIAL WORKS IN CONSULTATION WITH
THE LOCAL PLANNING AUTHORITY. RECOMMENDED WORK SHOULD BE
SCHEDULED AND LINKED TO THE APPROVED DEVELOPMENT PLAN. ALL WORK
MUST COMPLY WITH BS 5837:2005 AND BS 3998.
PROTECTION OF TREES
TREE PROTECTION
IS
SU
E 9
2014
CM
61
0
DAMAGE TO LIMBS
FIRE DAMAGE
SPOIL DUMP WILL
LEAD TO ROOT
SUFFOCATION
EXCAVATION
DAMAGE TO
STRUCTURAL AND
FEEDER ROOTS
ANY ACTIVITY AROUND
TREE WILL LEAD TO
COMPACTION AND
SUFFOCATION OF ROOTS
STORAGE OF BUILDING
MATERIALS AND SPILLAGE OF
FLUIDS WILL DAMAGE SURFACE
ROOTS
POOR PROTECTION -
DYING TREE
PROTECTIVE FENCE
ERECTED ONE METRE
OUTSIDE EDGE OF TREE
CANOPY TO INCLUDE ALL
ROOTING AREA
NO BONFIRES
NO STORAGE
NO DISTURBANCE
MAINTAIN FENCE IN AN
UPRIGHT CONDITION
THROUGHOUT THE
DEVELOPMENT PERIOD
NO EXCAVATION
NO HARD SURFACING
NO SITE HUTS
MINIMUM
1.2M HIGH
CORRECT PROTECTION
- HEALTHY TREE
TREE PROTECTION ZONE
TREE PROTECTION
ZONE 1
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
61
1
N.J.U.G. GUIDELINES FOR INSTALLING AND
MAINTAINING UTILITY SERVICES CLOSE TO TREES
DAMAGE TO TREES
[1] TREE ROOTS KEEP A TREE HEALTHY AND UPRIGHT. MOST ROOTS ARE FOUND IN THE TOP 600mm OF SOIL. THEY OFTEN GROW OUT
FURTHER THAN THE TREE'S HEIGHT. THE MAJORITY OF THESE ROOTS ARE VERY FINE; EVEN CLOSE TO A TREE FEW WILL BE THICKER THAN A
PENCIL. MOST STREET TREE ROOTS GROW UNDER THE PAVEMENT AND INTO THE FRONT GARDENS, BUT THEY CAN ALSO GROW UNDER THE
CARRIAGEWAY.
IF ROOTS ARE DAMAGED, FOR EXAMPLE BY TRENCHING, THE TREE MAY FALL OR LOSE ITS VIGOUR AND DECLINE.
[2] TREE TRUNKS CAN BE EASILY DAMAGED, SO BE CAREFUL WHEN WORKING NEAR THEM. FOR EXAMPLE, DO NOT LEAVE PAVING SLABS
AGAINST TREES, DO NOT CHAIN MACHINERY TO THEM OR NAIL SITE NOTICES TO THEIR TRUNKS.
PROTECTING ROOTS
[1] ESTABLISH A PROTECTION ZONE AROUND THE TREE: THE PRECAUTIONARY AREA [see below]
NO PRECAUTIONS
NECESSARY
PRECAUTIONS
ESSENTIAL
P
R
E
C
A
U
T
I
O
N
S
E
S
S
E
N
T
I
A
L
TRENCHLESS OR
MANUAL
EXCAVATION
OP
EN
E
XC
AV
AT
IO
N
IN THE PRECAUTIONARY AREA
[2] DO NOT EXCAVATE WITH MACHINERY. USE TRENCHLESS TECHNIQUES WHERE POSSIBLE. OTHERWISE ONLY DIG BY HAND.
WHEN HAND DIGGING, CAREFULLY WORK AROUND ROOTS, RETAINING AS MANY AS POSSIBLE.
DO NOT CUT ROOTS OVER 25mm IN DIAMETER, UNLESS THE COUNCIL'S TREE OFFICER AGREES BEFOREHAND.
PRUNE ROOTS WHICH HAVE TO BE REMOVED USING SHARP TOOLS [E.G. SECATEURS OR HANDSAW]. MAKE A CLEAN CUT AND LEAVE AS SMALL A
WOUND AS POSSIBLE.
BACKFILL THE TRENCH WITH AN INERT GRANULAR MATERIAL AND TOP SOIL MIX. COMPACT THE BACKFILL ONLY WITH EXCAVATED SOIL.
DO NOT REPEATEDLY MOVE/USE HEAVY MECHANICAL PLANT EXCEPT ON HARD STANDING.
DO NOT STORE SPOIL OR BUILDING MATERIAL, INCLUDING CHEMICALS AND FUELS.
[3] FROST CAN DAMAGE EXPOSED ROOTS. IF TRENCHES ARE TO BE LEFT OPEN OVERNIGHT, COVER THE ROOTS WITH DRY SACKING. REMEMBER
TO REMOVE THE SACKING BEFORE BACKFILLING.
PRECAUTIONARY AREA
P
R
E
C
A
U
T
I
O
N
A
R
E
A
TREE PROTECTION
ZONE 2
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
61
2
GR
OU
ND
WO
RK
S
SIT
E C
LE
AR
AN
CE
FO
UN
DA
TIO
NS
ST
OR
M A
ND
F
OU
L S
EW
ER
D
RA
IN
S
LA
Y S
ER
VIC
E D
UC
TW
OR
K
TIM
BE
R-F
RA
ME
SC
AF
FO
LD
IN
G - 3
S
ID
ES
TIM
BE
R F
RA
ME
D
ELIV
ER
Y A
ND
E
RE
CT
IO
N
SC
AF
FO
LD
IN
G - 4
th
S
ID
E
RO
OF
IN
G
BR
IC
KW
OR
K
FIR
ST
-F
IX
CA
RP
EN
TR
Y
EL
EC
TR
IC
AL
PL
UM
BIN
G
RE
MO
VE
S
CA
FF
OL
DIN
G
IN
SU
LA
TIO
N A
ND
D
RY
LIN
IN
G
GL
AZ
IN
G
SC
RE
ED
F
LO
OR
(1
D
AY
T
O L
AY
A
ND
4
D
AY
S T
O D
RY
)
CO
NN
EC
T S
ER
VIC
ES
GA
S
WA
TE
R
EL
EC
TR
IC
S
SE
CO
ND
-F
IX
CA
RP
EN
TR
Y
EL
EC
TR
IC
S
PL
UM
BIN
G
KIT
CH
EN
DE
CO
RA
TIN
G
EX
TE
RN
AL
W
OR
KS
DR
IV
EW
AY
PA
TH
S
FE
NC
IN
G
LA
ND
SC
AP
IN
G
BU
IL
DIN
G C
ON
TR
OL
IN
SP
EC
TIO
N
CE
RT
IF
IC
AT
E O
F C
OM
PL
ET
IO
N IS
SU
ED
IN
SU
RA
NC
E C
OM
PA
NY
IN
SP
EC
TIO
N
AC
TIV
IT
Y
ES
TIM
AT
ED
TIM
EF
RA
ME
WE
EK
1 2
3
4
5
6
7
8
9
1
0 1
1 1
21
3 1
4 1
5 1
6 1
7 1
8 1
9 2
0 2
1 2
2 2
3 2
4 2
5 2
6
2-3
W
EE
KS
1-2
D
AY
S
2-3
W
EE
KS
2-3
W
EE
KS
1 D
AY
2 W
EE
KS
1-2
W
EE
KS
1-2
D
AY
S
3 W
EE
KS
1-2
D
AY
S
5 D
AY
S
1 W
EE
K
2 W
EE
KS
1 W
EE
K
2 W
EE
KS
1 W
EE
K
3 W
EE
KS
1-2
W
EE
KS
1 D
AY
1 D
AY
TH
IS
P
RO
GR
AM
ME
H
AS
B
EE
N B
AS
ED
O
N ID
EA
L W
OR
KIN
G C
ON
DIT
IO
NS
. N
O A
LL
OW
AN
CE
H
AS
B
EE
N M
AD
E F
OR
A
DV
ER
SE
W
EA
TH
ER
C
ON
DIT
IO
NS
O
R D
EL
IV
ER
Y D
EL
AY
S. T
HIS
PR
OG
RA
MM
E IS
T
O B
E U
SE
D A
S A
G
UID
E F
OR
P
RO
GR
AM
MIN
G T
RA
DE
S IN
T
HE
C
OR
RE
CT
O
RD
ER
O
NL
Y, O
N A
W
EL
L P
LA
NN
ED
S
IT
E. IT
IS
N
OT
S
IT
E S
PE
CIF
IC
. .A
LT
ER
NA
TIV
E
OR
DE
R O
F T
RA
DE
SM
EN
M
AY
S
UIT
Y
OU
R S
IT
E B
ET
TE
R. A
W
EL
L O
RG
AN
IS
ED
S
IT
E C
AN
B
E T
HE
K
EY
A
DV
AN
TA
GE
IN
T
HE
S
PE
ED
O
F C
ON
ST
RU
CT
IO
N. D
ET
AIL
ED
P
RE
P
LA
NN
IN
G
IS
A
F
UN
DA
ME
NT
AL
R
EQ
UIR
EM
EN
T T
O M
AIN
TA
IN
T
HE
A
DV
AN
TA
GE
O
F U
SIN
G S
IP
S E
CO
P
AN
EL
S T
IM
BE
R F
RA
ME
C
ON
ST
RU
CT
IO
N.
SELF BUILD PROGRAMME
based on a 1800ft2 house
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
CM
61
3
PART E
ROBUST
DETAILING
This manual shows how to comply with Approved Document E of the Building Regulations 3) -
Resistance to the passage of sound, but does not achieve approval from Robust Details. The
details and information in this book are for guidance purposes only and are not exhaustive.
They are not site specific. Refer to the relevant design manual and panel drawings for the site,
which should be read in conjunction with the approved Building Regulation drawings and must
be adhered to and take priority over standard details.
ISSUE 9
2014
CONTENTS
1 FIXINGS SHEET 1
2 FIXINGS SHEET 2
3 GROUND FLOOR SOLEPLATE DETAILS
4 SOLEPLATE FIXINGS
5 FIRST FLOOR SOLEPLATE DETAIL
6 SIPS TO SIPS PANEL FIXING
7 TYPICAL WINDOW COMPONENTS AND ASSEMBLY
8 TYPICAL EXTERNAL DOOR COMPONENTS AND
ARRANGEMENTS
9 EXTERNAL WALL DETAIL
10 OPENINGS AND FIXINGS
11 WINDOW FIXING
12 ROOF FIXING
THIS MANUAL IS FOR GUIDANCE ONLY. IT IS NOT SITE SPECIFIC.
YOU MUST REFER TO THE DRAWINGS PROVIDED WITH EACH KIT
FOR DETAILS RELEVANT TO THE SITE YOU ARE WORKING ON.
SHOULD A DETAIL DIFFER TO SITE DRAWINGS - SITE DRAWINGS
WOULD USUALLY TAKE PREFERENCE. IF YOU HAVE ANY
QUESTIONS PLEASE CONTACT OUR CONTRACTS MANAGER IN THE
FIRST INSTANCE ON 01787 378567.
PART E ROBUST
DETAILING CONTENTS
IS
SU
E 9
2014
GROUND FLOORS NOT CONTINUOUS
BETWEEN DWELLINGS
FLEXIBLE OR ACOUSTIC SEALANT
(MAY BE OMITTED WHEN TIMBER
GROUND FLOOR IS USED)
GROUND FLOOR CONSTRUCTION:
TIMBER FLOOR JOISTS:
- MAY SPAN IN EITHER DIRECTION
- FLOOR DECKING MAY RUN UNDER SOLE PLATES
- CLOSE SPACES BETWEEN FLOOR JOISTS WITH FULL DEPTH TIMBER BLOCKING
WHERE JOISTS ARE AT RIGHT ANGLES TO WALL, OR
BEAM AND BLOCK FLOOR WITH ALL VOIDS FILLED WITH SAND AND CEMENT, OR
PRECAST CONCRETE PLANKS WITH ALL VOIDS BETWEEN PLANKS AND BLOCKWORK
FILLED WITH MORTAR OR FLEXIBLE SEALANT, OR
CAST IN-SITU CONCRETE SUSPENDED SLAB, OR
GROUND BEARING SLAB
*NOTE: ENSURE SUBSTRUCTURE MASONRY IS CORRECTLY SET OUT TO ENABLE TIMBER
FRAME TO ACHIEVE THE REQUIRED GAP BETWEEN WALL PANELS
ELEVATION
FLOOR ZONE
DPC
TO BE READ IN CONJUNCTION
WITH DETAIL E19 FOR FULL
CONSTRUCTION OF
SEPARATING WALL
7N DENSE BLOCKS OR
SIMILAR APPROVED. REFER
TO CM110 & CM111
FLOOR ZONE
GROUND FLOOR
JUNCTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E1
FLEXIBLE OR ACOUSTIC SEALANT
(MAY BE OMITTED WHEN TIMBER
GROUND FLOOR IS USED)
PERIMETER INSULATION, ISOLATING
SCREED FROM TIMBER FRAME
INSULATION ISOLATING SCREED
FROM RAFT
DPC
POLYTHENE
TO BE READ IN
CONJUNCTION WITH
PART E ROBUST
DETAIL E19 FOR FULL
CONSTRUCTION OF
SEPARATING WALL
7N DENSE BLOCKS OR
SIMILAR APPROVED.
GROUND FLOOR
JUNCTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E2
D.P.C.
D.P.C.
CONTINUOUS DPC
RETAINING WALL MAY NEED TO BE
DESIGNED BY ENGINEER
FLEXIBLE OR ACOUSTIC SEALANT
(MAY BE OMITTED WHEN TIMBER
GROUND FLOOR IS USED)
GROUND FLOOR CONSTRUCTION:
TIMBER FLOOR JOISTS:
- MAY SPAN IN EITHER DIRECTION
- FLOOR DECKING MAY RUN UNDER SOLE PLATES
- CLOSE SPACES BETWEEN FLOOR JOISTS WITH FULL DEPTH TIMBER BLOCKING
WHERE JOISTS ARE AT RIGHT ANGLES TO WALL OR
BEAM AND BLOCK FLOOR WITH ALL VOIDS FILLED WITH MORTAR, OR
PRECAST CONCRETE PLANKS WITH ALL VOIDS BETWEEN PLANKS AND BLOCKWORK
FILLED WITH MORTAR OR FLEXIBLE SEALANT, OR
CAST IN-SITU CONCRETE SUSPENDED SLAB, OR
GROUND BEARING SLAB
*NOTE: ENSURE SUBSTRUCTURE MASONRY IS CORRECTLY SET OUT TO ENABLE TIMBER
FRAME TO ACHIEVE THE REQUIRED GAP BETWEEN WALL PANELS
TO BE READ IN CONJUNCTION
WITH PART E ROBUST
DETAILING E19 FOR FULL
CONSTRUCTION OF
SEPARATING WALL
7N DENSE BLOCKS OR
SIMILAR APPROVED.
STAGGERED GROUND
FLOOR
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E3
MASONRY OUTER LEAF
Sips Eco Panel
EXTERNAL WALL CAVITY (MIN 50mm)
5mm (MIN) RESILIENT FLANKING STRIP
JOISTS MAY SPAN IN EITHER DIRECTION
SEAL ALL PERIMETER JOINTS WITH TAPE
OR CAULK WITH SEALANT
CLOSE SPACES BETWEEN FLOOR JOISTS
WITH FULL DEPTH TIMBER BLOCKING OR
CONTINUOUS HEADER JOIST WHERE JOISTS
ARE AT RIGHT ANGLES TO THE WALL
ELEVATION
2 LAYERS OF 15mm LAFARGE GTEC FIRE
BOARD. ALL PLASTERBOARD JOINTS SHOULD
BE STAGGERED WITH JOINTS FILLED AND
REINFORCED WITH LAFARGE GTEC JOINTING
SYSTEM
CLOSE CAVITY WITH A SLEEVED WIRE
REINFORCED MINERAL WOOL BATT CAVITY
STOP
EXTERNAL FLANKING
WALL JUNCTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E4
MA
SO
NR
Y O
UT
ER
LE
AF
(M
IN
100
mm
T
HIC
K,
OR
T
O S
UIT
D
ES
IG
N)
EX
TE
RN
AL
W
ALL C
AV
IT
Y (60
mm
)
IN
NE
R L
EA
F S
IP
S P
AN
EL. W
HE
RE
T
HE
RE
IS
NO
S
EP
AR
AT
IN
G F
LO
OR
E
.G
. F
OR
H
OU
SE
S;
1
2.5
mm
L
AF
AR
GE
E
B
OA
RD
O
N
10-25m
m B
AT
TE
NS
A
T 6
00m
m c/c.
IN
NE
R L
EA
F W
HE
RE
T
HE
RE
IS
A
SE
PA
RA
TIN
G F
LO
OR
E
.G
. F
OR
F
LA
TS
.
T
WO
LA
YE
R O
F 15m
m LA
FA
RG
E G
TE
C
FIR
E B
OA
RD
. A
LL
JO
IN
TS
S
TA
GG
ER
ED
AN
D R
EIN
FO
RC
ED
W
IT
H LA
FA
RG
E
GT
EC
JO
IN
TIN
G S
YS
TE
M.
CLO
SE
C
AV
IT
Y W
IT
H A
S
LE
EV
ED
W
IR
E
RE
IN
FO
RC
ED
M
IN
ER
AL W
OO
L B
AT
T C
AV
IT
Y
ST
OP
SE
AL A
LL P
ER
IM
ET
ER
JO
IN
TS
W
IT
H T
AP
E
OR
C
AU
LK
W
IT
H S
EA
LA
NT
PLAN
TO BE READ IN CONJUNCTION
WITH ROBUST DETAIL E19 FOR
FULL CONSTRUCTION OF
SEPARATING WALL
EXTERNAL FLANKING
WALL TO WALL
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E5
MASONRY OUTER LEAF (MIN 100mm THICK, OR TO SUIT DESIGN)
EXTERNAL WALL CAVITY
FOR PLASTERBOARD SPECIFICATION REFER TO ROBUST DETAIL 5
IF PRE-COMPLETION CERTIFICATE REQUIRED SEEK SPECIALIST ADVICE
CLOSE CAVITY WITH A SLEEVED WIRE
REINFORCED MINERAL WOOL BATT
CAVITY STOP TO COMPLETELY FILL
CAVITY WIDTH
SEAL ALL PERIMETER JOINTS WITH TAPE
OR CAULK WITH SEALANT
TO BE READ IN CONJUNCTION
WITH DETAIL E19 FOR FULL
CONSTRUCTION OF
SEPARATING WALL
STAGGERED PARTY
WALL USING STUDS
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E6
CLOSE CAVITY WITH A SLEEVED WIRE
REINFORCED MINERAL WOOL BATT
CAVITY STOP
SEAL ALL PERIMETER JOINTS WITH TAPE
OR CAULK WITH SEALANT
TO BE READ IN CONJUNCTION
WITH DETAIL 19 FOR FULL
CONSTRUCTION OF
SEPARATING WALL
MASONRY OUTER LEAF (MIN 100mm THICK, OR TO SUIT DESIGN)
EXTERNAL WALL CAVITY
FOR PLASTERBOARD SPECIFICATION REFER TO ROBUST DETAIL 5.
IF PRE-COMPLETION CERTIFICATE REQUIRED SEEK SPECIALIST ADVICE
STAGGERED PARTY
WALL USING SIPS
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E6
.1
MASONARY OUTER LEAF
EXTERNAL WALL CAVITY (MIN 50mm)
Sips Eco Panels
FOR PLASTERBOARD
SPECIFICATION REFER TO
ROBUST DETAIL 5
5mm (MIN) RESILIENT
FLANKING STRIP
JOISTS MAY SPAN IN EITHER
DIRECTION
TRIMMED BLOCKING TO END OF
JOIST
CLOSE SPACES BETWEEN
FLOOR JOISTS WITH FULL
DEPTH TIMBER BLOCKING OR
CONTINUOUS HEADER JOIST
WHERE JOISTS ARE AT RIGHT
ANGLES TO THE WALL
SITE FIXED SHEATHING BOARD FOR DEPTH
OF FLOOR
OPEN
PERPEND
CLOSE CAVITY WITH A SLEEVED WIRE
REINFORCED MINERAL WOOL BATT
CAVITY STOP
EXTERNAL WALL
FLOOR JUNCTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E7
MASONARY OUTER LEAF
EXTERNAL WALL CAVITY (MIN 50mm)
Sips Eco Panel
5mm (MIN) RESILIENT
FLANKING STRIP
JOISTS MAY SPAN IN EITHER
DIRECTION
SOFTWOOD TIMBER INFILL
BETWEEN SUPPORTING TOP
CHORDS/FLANGES OF JOISTS
BUILT INTO FRAME TO SUPPORT
FLOOR (BOTTOM CHORD NOT
BUILT INTO FRAME)
RING BEAMS PACKED TO STUD WIDTH
SEAL ALL PERIMETER JOINTS WITH TAPE
OR CAULK WITH SEALANT
CLOSE CAVITY WITH A SLEEVED WIRE
REINFORCED MINERAL WOOL BATT CAVITY
STOP
FOR PLASTERBOARD SPECIFICATION
REFER TO ROBUST DETAIL 5
FOR PLASTERBOARD SPECIFICATION
REFER TO ROBUST DETAIL 5
OPEN
PERPEND
EXTERNAL WALL TOP
CHORD SUPPORTED
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E8
SEAL ALL PERIMETER JOINTS
WITH TAPE OR CAULK WITH
SEALANT
WHERE REQUIRED INTERNAL
WALL TO COMPLY WITH
BUILDING REGULATIONS
REQUIREMENT E2
THIS DETAILSHOWS A JUNCTION DETAIL
WHERE THE INTERNAL WALL IS FIXED
THROUGH THE SEPARATING WALL LINING;
OTHER JUNCTION DETAILS ARE ACCEPTABLE
PROVIDED ALL JOINTS ARE SEALED WITH
TAPE OR CAULKED WITH SEALANT
PLAN
TO BE READ IN CONJUNCTION
WITH DETAIL E19 FOR FULL
CONSTRUCTION OF
SEPARATING WALL
INTERNAL SEPARATING
WALL JUNCTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E9
SEAL ALL PERIMETER JOINTS WITH
TAPE OR CAULK WITH SEALANT
HEAPLATE FIXED TO INTERNAL WALL
BEAMS
INTERNAL LOADBEARING WALL
5mm (MIN) RESILIENT FLANKING STRIP
SOFTWOOD TIMBER INFILL BETWEEN
SUPPORTING TOP CHORDS/FLANGES
WHERE REQUIRED
FLOOR DECKING
INTERNAL WALL BEAMS
HEADPLATE FIXED TO INTERNAL
WALL BEAMS
SOFTWOOD TIMBER NOGGINGS
FOR RESILIENT BAR SUPPORT
(LEAVE A SMALL GAP AT END OF
RESILIENT BAR)
METAL WEB JOIST
NOTE: DETAIL SHOWS TOP
CHORD/FLANGE SUPPORTED
LOADBEARING WALL
PARALLEL TO JOISTS
IS
SU
E 9
2014
E1
0
INTERNAL LOADBEARING WALL
5mm (MIN) RESILIENT FLANKING STRIP
SOFTWOOD TIMBER INFILL BETWEEN
SUPPORTING TOP CHORDS/FLANGES
WHERE REQUIRED
FLOOR DECKING
INTERNAL WALL BEAMS
HEADPLATE FIXED TO INTERNAL
WALL BEAMS
METAL WEB JOIST
SEAL ALL PERIMETER JOINTS
WITH TAPE OR CAULK WITH
SEALANT
NOTE: DETAIL SHOWS TOP CHORD/FLANGE SUPPORTED
LOADBEARING WALL
PERPENDICULAR TO
JOISTSIS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E1
1
5mm (MIN) RESILIENT
FLANKING STRIP
EXTRA METAL WEB JOIST
UNDER INTERNAL WALL
FLOOR DECKING
SOFTWOOD TIMBER
NOGGINGS FOR RESILIENT
BAR SUPPORT (LEAVE A
SMALL GAP AT END OF
RESILENT BAR)
HEADPLATE FIXED TO JOIST
SEAL ALL PERIMETER JOINTS
WITH TAPE OR CAULK WITH
SEALENT
NON LOADBEARING WALL
PARALLEL TO JOISTS
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E1
2
SEAL ALL PERIMETER JOINTS WITH
TAPE OR CAULK WITH SEALANT
HEADPLATE FIXED TO JOIST
WHERE REQUIRED INTERNAL WALL
TO COMPLY WITH BUILDING
REGULATIONS REQUIREMENT E2
5mm (MIN) RESILIENT FLANKING
STRIP
FLOATING FLOOR
METAL WEB JOIST
*NOTE - NON LOADINGBEARING
PARTITIONS MAY ALSO BE TAKEN
DIRECTLY OFF THE FLOATING
FLOOR TREATMENT, CHECK WITH
MANUFACTURER'S INSTRUCTIONS
FOR INSTALLATION
NON LOADBEARING WALL
PERPENDICULAR TO
JOISTSIS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E1
3
FLOOR DECKING: 39MM REDUC FOUNDATION EXTRA.
JOISTS: 240mm (MIN) TIMBER I-JOISTS
ABSORBENT MATERIAL: 100mm (MIN) MINERAL WOOL QUILT INSULATION (10-36 kg/m³)
BETWEEN JOISTS
DO:
LAY QUILT (MIN 100mm THICK) BETWEEN ALL JOISTS, INCLUDING DOUBLED UP
I-JOISTS, ENSURING NO GAPS REMAIN
ENSURE FLOATING FLOOR TREATMENT IS SUITABLE AND IS INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS
ENSURE QUILT IS LAID BETWEEN AND NOT UNDER FLOOR BATTENS
INSTALL FLANKING STRIPS AROUND THE PERIMETER OF THE FLOORING
BOARD TO ISOLATE FLOOR FROM WALLS AND SKIRTINGS
ENSURE RESILIENT CEILING BARS ARE FIXED AT RIGHT ANGLES TO THE
JOISTS
REFER TO ROBUST DETAIL 25 FOR CEILING SPECIFICATION.
STAGGER JOISTS IN CEILING LAYERS
39 REDUC FOUNDATION
EXTRA FLOOR DECKING
JOISTS
ABSORBENT MATERIAL
2 x 15mm PLASTERBOARD
18mm OSB WORKING
PLATFORM
25mm RESILIENT BARS
SEPARATING FLOOR
TREATMENT 1
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E1
4
FLOATING FLOOR
FLOOR DECKING
JOISTS
ABSORBENT
MATERIAL
CEILING
FLOOR DECKING: 15mm (MIN) WOOD BASED BOARD, DENSITY 600kg/m³
(MIN)
JOISTS: 240mm (MIN) TIMBER I-JOISTS
ABSORBENT MATERIAL: 100mm (MIN) MINERAL WOOL QUILT
INSULATION (10-36 kg/m³) BETWEEN JOISTS
DO:
LAY QUILT (MIN 100mm THICK) BETWEEN ALL JOISTS, INCLUDING
DOUBLED UP I-JOISTS, ENSURING NO GAPS REMAIN
ENSURE FLOATING FLOOR TREATMENT IS SUITABLE AND IS
INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS
ENSURE QUILT IS LAID BETWEEN AND NOT UNDER FLOOR
BATTENS
INSTALL FLANKING STRIPS AROUND THE PERIMETER OF THE
FLOORING BOARD TO ISOLATE FLOOR FROM WALLS AND
SKIRTINGS
ENSURE RESILIENT CEILING BARS ARE FIXED AT RIGHT ANGLES
TO THE JOISTS
REFER TO ROBUST DETAIL 25 FOR CEILING SPECIFICATION.
STAGGER JOISTS IN CEILING LAYERS
SEPARATING FLOOR
TREATMENT 2
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E1
5
PLY WEB JOISTS
.
18mm t & g FLOORING BOARD on
19mm GYPROC PLANK (nominally 13.5 kg/m²) on
RESILIENT COMPOSITE DEEP BATTENS AT 600mm c/c
(resilient bar must be continuous and pre-bonded to batten) on
15mm OSB 3 or 4 to BS EN 300
on FLOOR JOISTS
PLY WEB I JOISTS PROVIDE 2 LAYERS OF 15mm GYPSUM
PLASTERBOARD.
ULTRA JOISTS PROVIDE 2 LAYERS OF 15mm GYPROC SOUNDBLOC
ON BR1 GYPFRAME RESILIENT BARS AT MAXIMUM 450mm c/c.
MINERAL WOOL QUILT LAID BETWEEN
BATTENS;
13mm (min) 33-36 kg/m³ or
25mm (min) 10-36 kg/m³
SERVICES, WHERE
REQUIRED, MAY BE
LOCATED ABOVE OR
BELOW QUILT.
70
MIN
.
100mm (MIN) MINERAL WOOL QUILT INSULATION
(10-36kg/m³) BETWEEN JOISTS
SEPARATING FLOOR
TREATMENT 2.1
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E1
6
INTERNAL FLOORS SHOULD NOT BE
CONTINOUS BETWEEN DWELLINGS
FLOOR JOISTS MAY SPAN IN
EITHER DIRECTION
INTERNAL FLOOR TO COMPLY WITH
BUILDING REGULATIONS
REQUIREMENT E2
CLOSE SPACES BETWEEN FLOOR
JOISTS WITH FULL DEPTH TIMBER
BLOCKING WHERE JOISTS ARE AT
RIGHT ANGLES TO WALL
SEAL ALL PERIMETER JOINTS WITH
TAPE OR CAULK WITH SEALANT
TO BE READ IN CONJUNCTION
WITH E19 FOR FULL
CONSTRUCTION OF
SEPARATING WALL
CLOSE CAVITY WITH A SLEEVED
WIRE REINFORCED MINERAL
WOOL BATT CAVITY STOP
INTERMEDIATE FLOOR -
HOUSE
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E1
7
FLOATING FLOOR
FLOOR DECKING
JOISTS
ABSORBANT
MATERIAL
CEILING
JOIST TYPE
IMPORTANT
ONLY THE FOLLOWING METAL WEB
JOISTS MAY BE USED:
MiTek Posi-Joist
Prestoplan PresWeb
WOLF easi-joist
Gang Nail ecojoist
NOTES:
ALTHOUGH SINGLE HEADER AND
SOLEPLATES ARE INDICATED,
INCREASING THE NUMBER OF HEADER
AND SOLEPLATES WOULD BE
ACCEPTABLE, HOWEVER, ALL DIMENSION
SPECIFICATIONS WITHIN ROBUST
DETAILS MUCT BE ADHERED TO.
METAL WEB JOISTS CAN BE TOP
CHORD/FLANGE SUPPORTED OR FULLY
BUILT-IN AND SUPPORTED ON THE PANEL
AND THIS IS PERMITTED, HOWEVER, ALL
DIMENSION SPECIFICATIONS WITHIN
ROBUST DETAILS MUST BE AHERED TO.
NOTE THAT JOIST HANGERS MUST NOT
BE USED TO SUPPORT SEPARATING
FLOOR JOISTS
DO
ENSURE CORRECT METAL WEB
JOISTS ARE BEING USED (SEE JOIST
TYPE)
LAY QUILT (MIN 100mm THICK)
BETWEEN JOISTS ENSURING NO
GAPS REMAIN
ENSURE FLOATING FLOOR
TREATMENT IS SUITABLE AND IS
INSTALLED IN ACCORDANCE WITH
THE MANUFACTURER'S
INSTRUCTIONS
ENSURE QUILT WITHIN FLOATING
FLOOR IS LAID BETWEEN AND NOT
UNDER FLOATING FLOOR BATTENS
INSTALL RESILIENT FLANKING
STRIPS AROUND THE PERIMETER
OF THE FLOORING BOARD TO
ISOLATE FLOOR FROM WALLS AND
SKIRTINGS
ENSURE RESILIENT CEILING BARS
ARE FIXED AT RIGHT ANGLES TO
THE JOISTS
ENSURE TIMBER FLOOR CEILING
TREATMENT IS FIXED CORRECTLY
STAGGER JOINTS IN CEILING
LAYERS
TIMBER FRAME AND METAL
WEB JOISTS
SEPARATING FLOOR
CONSTRUCTION
METAL WEB JOISTSIS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E1
8
WALL
WIDTH
WALL LINING
SHEATHING
ABSORBENT
MATERIAL
STUD WALL
WALL WIDTH: 262mm BETWEEN INNER FACES OF WALL LININGS. 50mm CAVITY
WALL LINING: 2 LAYERS OF 15mm GYPROC WALLBOARD WITH JOINTS STAGGERED.
SHEATHING: 11mm THICK OSB BOARD.
ABSORBENT MATERIAL: 60mm (MIN) MINERAL WOOL BATTS OR QUILT (DENSITY 10 - 60kg/m³) BOTH
SIDES. MATERIAL MAY BE UNFACED, PAPER FACED OR WIRE REINFORCED.
Sips Eco Panel
WALL WIDTH 288mm BETWEEN INNER FACES OF WALL LININGS. 50mm CAVITY
WALL LINING: 2 LAYERS OF 15mm GYPROC WALLBOARD WITH JOINTS STAGGERED ON 25mm
BATTENS. INFILL BETWEEN BATTENS WITH MINERAL WOOL INSULATION.
TIES (where required structurally): TIES BETWEEN FRAMES NOT MORE THAN 40mm x 3mm, AT 1200mm
(MIN) CENTRES HORIZONTALLY, ONE ROW OF TIES PER STOREY HEIGHT VERTICALLY.
DO:
KEEP WALL LININGS AT LEAST 240mm APART
ENSURE THAT THE 50mm (MIN) GAP BETWEEN THE WALL PANELS IS MAINTAINED.
ENSURE QUILT OR BATTS COVER WHOLE LINING AREA, FITTING TIGHT BETWEEN STUDS
WITHOUT SAGGING.
ENSURE THAT ALL CAVITY STOPS/CLOSERS ARE FLEXIBLE OR ARE FIXED TO ONE FRAME
ONLY.
MAKE SURE THERE IS NO CONNECTION BETWEEN THE TWO LEAVES EXCEPT WHERE TIES
ARE NECESSARY FOR STRUCTURAL REASONS (SEE ABOVE)
STAGGER JOINTS IN WALL LININGS TO AVOID AIR PATHS.
SEAL ALL JOINTS IN OUTER LAYER WITH TAPE OR CAULK WITH SEALANT.
WALL
WIDTH
WALL LINING
Sips Eco Panel
POLYSTYRENE WITH
DENSITY OF 18kg/m3
95mm x 45mm STUDS AT 600mm c/c 119 Sips Eco Panel
(NOT APPROVED BY ROBUST DETAILS).
SERVICE
BATTENS
SEPARATING WALL
CONSTRUCTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E1
9
REFER TO SEPARATING
COMPARTMENT WALL DETAIL
IF USING WALL REQUIRING
PRE-COMPLETION TESTING -
SEEK SPECIALIST ADVICE
REFER TO CM 510 FOR
PLASTERBOARD SPECIFICATION.
5mm (MIN) RESILIENT FLANKING
STRIP
CLOSE SPACES BETWEEN
FLOOR JOISTS WITH FULL
DEPTH TIMBER BLOCKING OR
CONTINUOUS HEADER JOIST
WHERE JOISTS ARE AT RIGHT
ANGLES TO THE WALL
JOISTS MAY SPAN IN EITHER
DIRECTION
SEAL ALL PERIMETER JOINTS
WITH TAPE OR CAULK WITH
SEALANT
CLOSE CAVITY WITH A SLEEVED
WIRE REINFORCED MINERAL
WOOL BATT CAVITY STOP
FLOOR DECKING RUNS UNDER
SOLE PLATE
SEPARATING WALL
CONSTRUCTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E2
0
REFER TO SEPARATING
COMPARTMENT WALL DETAIL
IF USING WALL REQUIRING
PRE-COMPLETION TESTING -
SEEK SPECIALIST ADVICE
REFER TO CM 510 FOR
PLASTERBOARD SPECIFICATION.
5mm (MIN) RESILIENT FLANKING
STRIP
CLOSE SPACES BETWEEN
FLOOR JOISTS WITH FULL
DEPTH TIMBER BLOCKING OR
CONTINUOUS HEADER JOIST
WHERE JOISTS ARE AT RIGHT
ANGLES TO THE WALL
JOISTS MAY SPAN IN EITHER
DIRECTION
SEAL ALL PERIMETER JOINTS
WITH TAPE OR CAULK WITH
SEALANT
CLOSE CAVITY WITH A SLEEVED
WIRE REINFORCED MINERAL
WOOL BATT CAVITY STOP
FLOOR DECKING RUNS UNDER
SOLE PLATE
SEPARATING FLOOR
CONSTRUCTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E2
1
SEAL ALL PERIMETER JOINTS
WITH TAPE OR CAULK WITH
SEALANT
WHERE REQUIRED INTERNAL
WALL TO COMPLY WITH
BUILDING REGULATIONS
REQUIREMENT E2
5mm (MIN) RESILIENT
FLANKING STRIP
LOAD
BEARING
NON LOAD
BEARING
RESILIENT BAR NOGGING
SEAL ALL PERIMETER JOINTS WITH
TAPE OR CAULK WITH SEALANT
HEADPLATE FIXED TO RESILIENT BAR
NOGGING
ADDITIONAL SUPPORT TO PARTITION
WHERE REQUIRED INTERNAL WALL TO
COMPLY WITH BUILDING REGULATIONS
REQUIREMENT E2
ELEVATIONS
INTERNAL WALLS FLOOR
TO CEILING
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E2
2
ELECTRICAL SOCKETS, SWTICHES, ETC.
STAGGER SOCKETS, SWITCHES, ETC.
ON EACH SIDE OF THE WALL SUCH
THAT THEY ARE NOT POSITIONED IN
OPPOSITE BAYS
PIPED SERVICES
SERVICE DUCT WITHIN
SEPARATING WALL
TO BE READ IN CONJUNCTION
WITH E19 FOR FULL
CONSTRUCTION OF
SEPARATING WALL
SURROUND SOCKETS IN
30mm PLASTERBOARD
25 20kg/m3 MINERAL
WOOL
STAGGER PIPED SERVICES ON
EACH SIDE OF THE WALL SUCH
THAT THEY ARE NOT
POSITIONED IN OPPOSITE
BAYS
SEPARATING WALL -
SOCKETS AND SERVICES
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E2
3
25mm (MIN) MINERAL WOOL QUILT
(10-36kg/m³) AROUND PIPE
PIPE BOXED IN WITH TWO LAYERS OF
GYPSUM-BASED BOARD COMBINED
NOMINAL 16kg/m²
5mm (MIN) FLANKING
STRIP
ALL VOIDS AROUND
PIPE SEALED
SEPARATING FLOOR
PIPE PENETRATION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E2
4
DOWNLIGHTERS AND RECESSED LIGHTING
DOWNLIGHTERS OR RECESSED LIGHTING MAY BE
INSTALLED IN THE CEILING:
IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS
AT NO MORE THAN ONE LIGHT PER 2m² OF
THE CEILING AREA IN EACH ROOM UNLESS
THE USE OF A GREATER DENSITY OF LIGHT
FITTINGS IS SUPPORTED BY TESTING
UNDERTAKEN IN ACCORDANCE WITH
AT CENTRES NOT LESS THAN 0.75m
INTO OPENINGS NOT EXCEEDING 100mm
DIAMETER OR 100 x 100mm
PARTICULAR ATTENTION SHOULD ALSO BE PAID
TO BUILDING REGULATIONS PART B - FIRE SAFETY
CEILING BOARD FIXINGS MUST NOT PENETRATE
OR TOUCH JOISTS
16mm (MIN) RESILIENT BARS WITH CT1 AND CT2
16mm (MIN) METAL RESILIENT CEILING BARS
MOUNTED AT RIGHT ANGLES TO THE JOISTS AT
400mm CENTRES (BARS MUST ACHIEVE A MINIMUM
LABORATORY PERFORMANCE OF rd∆Rw+Ctr=17dB
AND rd∆Lw=16dB)
CEILING TREATMENT CT1
TWO LAYERS OF GYPSUM-BASED BOARD,
COMPOSED OF 19mm (NOMINAL 13.5 kg/m²) FIXED
WITH 32mm SCREWS, AND 12.5mm (NOMINAL
10kg/m²) FIXED WITH 42mm SCREWS
CEILING TREATMENT CT2
TWO LAYERS OF GYPSUM-BASED BOARDS
COMPOSED OF 15mm (NOMINAL 12.5kg/m²) FIXED
WITH 25mm SCREWS AND SECOND LAYER OF
15mm GYPSUM-BASED BOARD (NOMINAL 12.5kg/m²)
FIXED WITH 42mm SCREWS
25mm (MIN) RESILIENT BARS WITH CT3
25mm (MIN) METAL RESILIENT CEILING BARS
MOUNTED AT RIGHT ANGLES TO THE JOISTS AT
400mm CENTRES (BARS MUST ACHIEVE A MINIMUM
LABORATORY PERFORMANCE OF rd∆Rw+Ctr=17dB
AND rd∆Lw=16dB)
CEILING TREATMENT CT3
TWO LAYERS OF GYPSUM-BASED BOARD,
COMPOSED OF 10mm (NOMINAL 12kg/m²) FIXED
WITH 30mm SCREWS AND SECOND LAYER OF
10mm (NOMINAL 12kg/m²) FIXED WITH 30mm
SCREWS
CEILING TREATMENT
TIMBER FLOOR CEILING TREATMENT MUST BE EITHER
CT1. CT2 OR CT3 (SEE BELOW). ALL JOINTS TO OUTER
LAYERS OF CEILING MUST BE SEALED WITH TAPE OR
CAULKED WITH SEALENT.
THE MAXIMUM LOAD ON RESILIENT BARS SHOULD NOT
EXCEED THAT SPECIFIED IN THE MANUFACTURER'S
INSTRUCTIONS
ENSURE CEILING LAYERS HAVE STAGGERED JOINTS
SERVICES MUST NOT PUNCTURE CEILING LININGS
(EXCEPT CABLES, WHICH SHOULD BE SEALED AROUND
WITH FLEXIBLE SEALENT)
CEILING
TREATMENT
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E2
5
ABSORBENT MATERIAL NOT
REQUIRED IN SEPARATING
WALL ABOVE CEILING
EXTERNAL WALL CAVTIY
CLOSED AT EAVES LEVEL
WITH A FLEXIBLE MATERIAL
(E.G MINERAL WOOL). IF A
RIGID MATERIAL IS USED,
THEN IT SHOULD ONLY BE
BONDED TO ONE LEAF
JUNCTION BETWEEN
SEPARATING WALL AND ROOF
FILLED WITH FLEXIBLE
CLOSER
CAVITY SEPARATING WALL
CONTINUOUS TO UNDERSIDE
OF ROOF
REFER TO ROBUST DETAIL 5
FOR PLASTERBOARD
SPECIFICATION.
100mm (MIN) MINERAL WOOL
INSULATION, 10kg/m³ (MIN),
BETWEEN CEILING JOISTS
SEAL ALL PERIMETER JOINTS
WITH TAPE OR CAULK WITH
SEALANT
ROOF JUNCTION
IS
SU
E 9
2014
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
E2
6