contact armature arm.eu.pdf · gost 839-80 matrix of pressing dimensions, mm weight, kg b d d l l 1...

33
CONTACT ARMATURE

Upload: others

Post on 22-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

CONTACTARMATURE

Page 2: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

NOMINATION:

For branching aluminum and steel-aluminum wires from highway conductors with open busbar switchgear. OA-120-600T-2 hasthermodynamic (plasma) coating contact surface. Clamps meet TU 34 13.10703-91.

DesignationDiameterof wires,

mm

Matrix of pressing

Dimensions, mm Weight,

kgDd

L L1min max

OA-10-1 4,5 ASH-2A-7,8 10 5,0 5,75 95,0

60

0,022

OA-16-1 5,1 - 5,6 ASH-2A-9,5 12 6,0 6,75 97,0 0,036

OA-25-1 6,4 - 6,9 ASH-2A-11,3 14 8,0 8,9 99,0 0,046

OA-35-1 7,5 - 8,4 ASH-2A-13,0 16 9,0 9,9 101,0 0,060

OA-50-1 9,0 - 9,6 ASH2A-14,3 18 11,0 12,1 103,0 0,075

OA-70-1 10,7 - 12,3 ASH-2A-16,5 20 13,0 14,1 115,070

0,097

OA-95-1 13,5 - 14,0 ASH-2A-18,2 22 15,0 16,1 117,0 0,110

OA-120-1 15,4 - 15,8 ASH-2A-20,8 25 16,3 17,8 130,080

0,170

OA-150-1 16,8 - 17,5 ASH-23,4 28 18,0 19,1 133,0 0,230

OA-185-1 18,8 - 20,0 ASH-26,0 32 20,3 21,8 152,0 90 0,320

OA-240-1 21,6 - 22,4 ASH-30,3 36 23,3 24,8 166,0100

0,435

OA-300-1 24,0 - 25,6 A-40,5 47 27,0 28,3 184,5 1,000

OA-400-1 27,3 - 30,6 A-45 52 31,5 33,1 209,0 120 1,300

OA-600-1 31,5 - 33,2 A-51 58 34,5 36,1 245,0 140 1,890

CLAMPS TAPPING PRESSING TYPE OA OA

compressing direction

com

pre

ssin

g d

irect

ion

109

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 3: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

DesignationDiameter of wires,

mmMatrix

of pressing

Dimensions, mm Weight, kg

A D d L L1

H S

OA-120T-2 15,4 - 5,8 MSSH-2A-20,8

40

25 16,5 13080

150 9 0,37

OA-150T-2 16,8 - 17,5 MSH-23,4 28 18,0 133 155

11

0,42

OA-185T-2 18,8 - 20,0 MSH-26,0 32 20,5 152 90 170 0,51

OA-240T-2 21,6 - 22,4 MSH-30,3

60

36 23,5 166100

175 0,69

OA-300T-2 24,0 - 25,6 A-40,5 47 27,0 184,5 19513

1,25

OA-400T-2 27,3 - 30,6 A-45 52 32,0 209 120 205 1,55

OA-600T-2 31,5 - 33,2 A-51 58 34,5 245 140 225 15 2,14

CLAMPS TAPPING PRESSING TYPE OA OA

NOMINATION:

For branching aluminum and

conductors with open busbar switchgear. OA-120-600T-2 hasthermodynamic (plasma) coating contact surface. Clamps meet TU 34 13.10703-91.

steel-aluminum wires from highway

110

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 4: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

NOMINATION:

For branching cooper conductorsfrom main line using bus-bar fitting on open distribution devices.Clampsmeet TU 34 13,10703-91.

DesignationType of wires by

GOST 839-80Matrix

of pressing

Dimensions, mm Weight, kg

B D d L L1

OM-35-1 M35 A-13 13 16 10 10160

0,168

OM-50-1 M50 Ñ-15 15 18 11 103 0,225

OM-70-1 M70 Ñ-17 17 20 12 11570

0,321

OM-95-1 M95 Ñ-19 19 23 14 118 0,420

OM-120-1 M120 Ñ-21 21 26 16 13180

0,573

OM-150-1 M150 Ñ-23 23 28 18 133 0,630

OM-185-1 M185 Ñ-26 26 30 20 150 90 0,810

OM-240-1 M240 Ñ-29 29 34 22 164100

1,184

OM-300-1 M300 Ñ-31,5 31 36 24 166 1,275

OM-400-1 M400 Ñ-36 36 42 28 202 120 2,160

CLAMPS TAPPING PRESSING TYPE OM OM

compressing direction

com

pre

ssin

g d

irect

ion

111

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 5: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

DesignationType of wire by

GOST 839-80Matrix of pressing

Dimensions, mm Weight, kg

B B1

D d L L1

H S

OM-35-2 M35 A-13 13 30 16 10 101 60 125 4 0,38

OM-50-2 M50 Ñ-15 15

40

18 11 103 60 130 4 0,45

OM-70-2 M70 Ñ-17 17 20 12 115 70 135 4 0,54

OM-95-2 M95 Ñ-19 19 23 14 118 70 140 5 0,60

OM-120-2 M120 Ñ-21 21 26 16 131 80 145 5 0,80

OM-150-2 M150 Ñ-23 23 28 18 133 80 150 5 0,78

OM-185-2 M185 Ñ-26 26 30 20 150 90 155 5 0,98

OM-240-2 M240 Ñ-29 29

60

34 22 164 100 160 8 1,32

OM-300-2 M300 Ñ-31,5 31 36 24 166 100 165 8 1,54

OM-400-2 M400 Ñ-36 36 42 28 202 120 190 8 2,31

CLAMPS TAPPING PRESSING TYPE OM OM

NOMINATION:

from main line using busbar fitting on open distribution devices. Clamps meet

For branching cooper conductors

TU 34 13,10703-91.

compressing direction

112

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 6: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

T - thermodynamic method of application of copper on the contact surface

NOMINATION:

For branching hollow aluminum from highway with open busbar switchgear. Clamps meet TU 34 27.10256-81.

OAP-500-1

OAP-640-1, OAP-640-1A

CLAMPS TAPPING PRESSING TYPE OAP OAP

compressing direction compressing direction

com

pre

ssin

g d

irect

ion

compressing direction compressing direction

com

pre

ssin

g d

irect

ion

113

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 7: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

OAP-500T-2

OAP-640T-2, OAP-640T-2A

CLAMPS TAPPING PRESSING TYPE OAP OAP

T - thermodynamic method of application of copper on the contact surface

NOMINATION:

For branching hollow aluminum from highway with open busbar switchgear. Clamps meet TU 34 27.10256-81.

compressing direction compressing direction

compressing directioncompressing direction

114

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 8: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

ZOAP-500T-1

Designation

Typ

e o

f w

ire b

yT

U 1

6-5

05-

397-7

2

Matr

ix b

yp

ressin

g

Dimensions, mm W

eig

ht,

kg

B D d L L1

L2

I I1

I2

I3

OAP-500-1PA500

A-59 58 65 47478

265 315350 175

14095

5,19

OAP-500T-2 260 - - 4,6

ZOAP-500T-1 - - - 140 - - - 9,78

OAP-640-1

PA640

MSH-70 - 80 60

650 392 452 450 225 200 100 11,45

OAP-640-1A 580 375 425 400 200 - 125 8,95

OAP-640T-2 610 390 - 410 205 - 120 10,57

OAP-640T-2A 580 390 - 400 200 - 120 10,37

CLAMPS TAPPING PRESSING TYPE OAP OAP

T - thermodynamic method of application of copper on the contact surface

NOMINATION:

For branching hollow aluminum wires from main line with busbar fitting of open distribution devices Clamps meet TU 34 27.10256-81

Protective screen

com

pre

ssin

g d

irect

ion

115

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 9: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

Designation

Interval of wire diameters

by GOST 839-80, mm

Matrix of pressing

Dimensions, mm

Weig

ht,

kg

B D d L I I1

ROA-185-1 18,8 - 20,0 ASH-27,0 29,75 32 20,5 242 180 90 0,54

ROA-240-1 21,6 - 22,4 ASH-31,2 35 36 23,5 266 200 100 0,67

ROA-300-1 24,0 - 25,6ASH-39,8

or A-40,539,5 47 27 364,5 280 100 1,43

ROA-400-1 27,3 - 33,6ASH-43,3or A-45

44 52 32 379 280 120 1,82

ROA-500-1 37,5 ASH-65 75 75 39,5 430 280 140 4,9

NOMINATION:

For branching wire from

highway without cutting it, as well as branching from the

systemat the substations with a mounted busbar

Clamps meet TÓ 34 13.10703-91.

CLAMPS SLITTING TAPPING TYPE ROA ROA

com

pre

ssin

g d

irect

ion

compressing direction

116

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 10: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

AOA-3/2

AOA-3/3

AOA-4/3-1

T - thermodynamic method of application of copper on the contact surface

NOMINATION:

For branching in the bays of ODD substation using wires P A 500.Clamps meet TU 34 27.10208-81.

Designation Matrix of pressing Dimensions, mm

Weight, kg B D d

AOA-3/2T

A-59 58 65 47

18,56

AOA-3/3T 19,71

AOA-4/3-1T 26,20

CLAMPS TAPPING PRESSING TYPE OAO OAO

compressing direction compressing direction

com

pre

ssin

g d

ire

ctio

n

compressing direction compressing direction

com

pre

ssin

g d

irect

ion

compressing direction compressing direction

com

pre

ssin

g d

irect

ion

117

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 11: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

T - thermodynamic method of application of copper

on the contact surface

P - contact aluminum plate with a copper layer.

NOMINATION:

For attaching one aluminum or steel-aluminum wire to

output of hardware. Clamps meet

TU 3449-016-52819896-05.

DesignationType of wire byGOST 839-80

Interval of wire,

mm

Matrix of pressing

Dimensions, mmWeight,

kgL L1

S

A1A-10-2A T(P) AS10/1,8 4,5 MSH-2A-13,0 124 60 6 0,053

A1A-16-2A T(P) A16 AS16/2,7 5,1 - 5,6 MSH-2A-13,0 124 60 6 0,055

A1A-25-2A T(P) A25; AS25/4,2 6,4 - 6,9 MSH-2A-13,0 124 60 6 0,068

A1A-35-2A T(P) A35; AS35/6,2 7,5 - 8,4 MSH-2A-13,0 124 60 6 0,067

A1A-50-2A T(P) A50; AS50/8,0 9,0 - 9,6 MSH-2A-14,3 126 60 6 0,072

A1A-70-2A T(P) A70; AS70/11,0 10,7 - 11,4 MSH-2A-16,5 139 70 7 0,077

A1A-95-2A T(P) A95; AS95/16 12,3 - 13,5 MSH-2A-18,2 139 70 8 0,115

A1A-120-2A T(P)A120; AS120/19;

AS70/72; A150; AS120/2714,0 - 15,8 MSH-2A-20,8 152 80 8 0,138

CLAMPS HARDWARE PRESSING A1A A1A

compressing direction

118

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 12: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

T - thermodynamic method of application of copper on the contact surface

P - contact aluminum plate with a copper layer.

NOMINATION:

For attaching one aluminum or steel-aluminum wire tooutput of hardware when installing outdoor switchgear. Clamps meet

TU 34 49-016-52819896-05.

A2A-35/240-2A T(P)

DesignationType of wire

by GOST 839-80

Intervalof wire

diameter, mm

Matrixof pressing

Dimensions, mm Weight,

kgB L L1

S

A2A-35-2A T(P) A35; AS35/6,2 7,5 - 8,4 MSH-2A-13,0 36 159 60 6 0,091

A2A-50-2A T(P) A50; AS50/8,0 9,0 - 9,6 MSH-2A-14,3 36 161 60 6 0,096

A2A-70-2A T(P) A70; AS70/11 10,7 - 11,4 MSH-2A-16,5 36 174 70 7 0,105

A2A-95-2A T(P) A95; AS95/16 12,3 - 13,5 MSH-2A-18,2 36 174 70 8 0,119

A2A-120-2A T(P)A120; A150; AS70/72; AS120/19; AS120/27

14,0 - 15,8 MSH-2A-20,8 36 187 80 8 0,142

A2A-150T-2A T(P)A185; AS150/19;

AS150/24; AS150/3416,8 - 17,5 ASH-2A-24,2 56 187 80 11 0,252

A2A-185T-2A T(P)A240; AS185/24;

AS185/29; AS95/141; AS185/43; AS205/27

18,8 - 20,0 ASH-2A-26,2 56 191 90 11 0,300

A2A-240T-2A T(P)A300; AS240/32;

AS240/39; AS240/5621,6 - 22,4 ASH-31,2 56 203 100 11 0,352

CLAMPS HARDWARE PRESSING WITH TWO HOLES A2A

compressing direction

119

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 13: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

T - thermodynamic method of application of copper

on the contact surface

P - contact aluminum plate with a copper layer

NOMINATION:

To join one of aluminum or steel-aluminum wire to

hardware outputs when installing outdoor switchgear.

Clamps meet TU 3449-016-52819896-05.

A2A-300/600-2 T(P)

DesignationType of wire byGOST 839-80

Intervalof wire

diameters, mm

Matrix of

pressing

Dimensions, mm Weight,

kgL L1

S

A2A-300-2 T(P)

AS300/39; AS300/48;AS300/66; AS300/67;AS330/30; AS330/43;AS400/18; AS400/22;

A350; A400

24,0 - 26,6 A-40,5 220 100 12 0,55

A2A-400-2 T(P)

AS400/51; AS400/64;AS400/93; AS450/56;

AS300/204; AS500/26;AS500/27; AS500/64;

A450; A500; A550

27,3 - 30,6 A-45,0 240 120 12 0,69

A2A-600-2 T(P)AS550/71; AS600/72;

A600; A65031,5 - 33,2 A-51,0 260 140 14 0,94

CLAMPS HARDWARE PRESSING A2A A2A

compressing direction

120

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 14: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

T - thermodynamic method of application of copper on the contact surface

P - contact aluminum plate with a copper layer

A4A-70/240-2 T(P)

A4A-300/600-2 T(P)

DesignationType of wiresby GOST 839-80

Interval of wire diameter

mm

Matrix

of pressing

Dimensions, mmWeight,

kgL L1

S

A4A-70-2 T(P) A70; AS70/11 10,7 - 11,4 MSH-2A-16,5 185 70 6 0,201

A4A-95-2 T(P) A95; AS95/16 12,3 - 13,5 MSH-2A-18,5 198 80 8 0,253

A4A-120-2 T(P)A120; A150; AS70/72;AS120/19; AS120/27

14,0 - 15,8 MSH-2A-20,8 198 80 8 0,274

A4A-150-8 T(P) A185; AS150/19; AS150/24; AS150/34 16,8 - 17,5 ASH-23,4 230 80 10 0,388

A4A-185-8 T(P)A240; AS95/141; AS185/24;

AS185/29; AS185/43; AS205/2718,8 - 20,0 ASH-26 245 90 10 0,416

A4A-240-8 T(P) A300; AS240/32; AS240/39; AS240/56 21,6 - 22,4 ASH-30,3 255 100 10 0,514

A4A-300-2 T(P)AS300/39; AS300/48; AS300/66;AS300/67; AS330/30; AS330/43;AS400/18; AS400/22; A350; A400

24,0 - 26,6 A-40,5 220 100 12 0,611

A4A-400-2 T(P)AS400/51; AS400/64; AS400/93;

AS450/56; AS300/204; AS500/26;AS500/27; AÑ500/64; A450; A500; A550

27,3 - 30,6 A-45,0 240 120 12 0,721

A4A-600-2 T(P) AS550/71; AS600/72; A600; A650 31,5 - 33,2 A-51,0 260 140 14 0,961

CLAMPS HARDWARE PRESSING A4A A4A

NOMINATION:

To join one of aluminum or steel-aluminum wire tohardware outputs when

installing outdoor switchgear.Clamps meet TU 3449-016-52819896-05.

compressing direction

compressing direction

121

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 15: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

DesignationType of cooper wire

by GOST 839-80Matrix

of pressing

Dimensions, mm Weight,

kg B L L1

S

A1M-35-2 M35 A-13 30132 60

4

0,15

A1M-50-2 M50 A-15

40

0,19

A1M-70-2 M70 S-17 14270

0,24

A1M-95-2 M95 S-19 146

5

0,32

A1M-120-2 M120 S-21160 80

0,40

A1M-150-2 M150 S-23 0,45

A1M-185-2 M185 A-26 174 90 0,53

A1M-240-2 M240 A-29

60185 100

8

0,85

A1M-300-2 M300 S-31,5 1,08

A1M-400-2 M400 A-36 210 120 1,50

CLAMPS HARDWARE PRESSING A1M A1M

NOMINATION:

To join one of aluminum or steel-aluminum wire to

hardware outputs when installing outdoor switchgear.

Clamps meet TU 3449-016-52819896-05.

compressing direction

122

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 16: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

NOMINATION:

For attaching one wire to hardware outputs. Clamps meet TU 3449-015-40064547-01.

DesignationType of cooper wire

by GOST 839-80

Matrix

of pressing

Dimensions, mmWeight,

kgB L L1

S

A2M-35-2 M35 A-13 30172 60

4

0,17

A2M-50-2 M50 A-15

40

0,22

A2M-70-2 M70 S-17 18270

0,36

A2M-95-2 M95 S-19 186

5

0,39

A2M-120-2 M120 S-21200 80

0,49

A2M-150-2 M150 S-23 0,55

A2M-185-2 M185 A-26 214 90 0,68

A2M-240-2 M240 A-29

60225 100

8

0,88

A2M-300-2 M300 A-31,5 0,97

A2M-400-2 M400 A-36 250 120 1,48

CLAMPS HARDWARE PRESSING A2M A2M

compressing direction

123

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 17: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

NOMINATION:

For attaching one cooper wire. Clamps meet

TU 3449-015-40064547-01.

A4M

DesignationType of cooper wire

by GOST 839-80Matrix

of pressing

Dimensions, mm Weight,

kgL L1

S

A4M-70-2 M70 S-17 18270

4 0,52

A4M-95-2 M95 S-19 186

5

0,57

A4M-120-2 M120 S-21200 80

0,67

A4M-150-2 M150 S-23 0,71

A4M-185-2 M185 S-26 214 90 0,77

A4M-240-2 M240 A-29225 100

8

0,96

A4M-300-2 M300 S-31,5 1,10

A4M-400-2 M400 A-36 250 120 1,92

CLAMPS HARDWARE PRESSING A4M A4M

compressing direction

124

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 18: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

A2AP

A4AP

NOMINATION:

For attaching one aluminum hollow wire to hardware putouts. Clamps meet

TU 3449-016-52819896-05.

T - thermodynamic method of application of copper on the contact surface

P-contact aluminum plate with a copper layer

DesignationType of wire

by TU 16-505-397-72Matrix

of pressing

Dimensions, mm Weight,

kgA B d L L1

L2

S

A2AP-500-2 T(P) PA-500A-59

45

60 14

270140

8020

1,08

A2AP-500-2A T(P) PA-50060

290100

1,16

A2AÏ-640-2A T(P) PA-640 MSH-70 380 200 24 2,11

A4AP-500-1A T(P) PA-500 A-59 45 270 140 80 14 1,66

A4AP-640-1 T(P) PA-640 MSH-70 60 100 18 380 200 100 24 2,43

A2AP-640-1A∗ T(P) PA-640 ASH-70 60 60 14 380 200 100 25 7,99

A4AP-640-1A∗ T(P) PA-640 ASH-70 60 100 18 380 200 100 25 8,6

∗ clamps of higher reliability (with a flexible input)

CLAMPS HARDWARE PRESSING FOR HOLLOW WIREA2AP,A4AP

compressing direction

compressing direction

125

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 19: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

T - thermodynamic method of application of copper

on the contact surface

P - contact aluminum plate

with a copper layer

NOMINATION:

For attaching one aluminumhollow wire to hardware outputs.

Clamps meetTU 3449-016-52819896-05.

Fig. 1 Fig. 2

Fig. 3

Designation Fig.Type of wire

by TU 16-505-397-72Matrix

of pressingL, mm

Weight,kg

A6AP-640-1 T(P)1

PA-640

A-74

401 4,17

A6AP-640-1Á T(P) 371 5,7

A6AP-640-2 T(P)2

400 7,5

A6AP-640-2Á T(P) 380 5,7

A6AP-640-3 T(P) 3 ASH-70 440 2,87

A6AP-640-1A∗ T(P) 1 A-74 401 8,6

A6AP-640-2A∗ T(P) 2 A-74 400 13,6

A6AP-640-3A∗ T(P) 3 ASH-70 440 9,36

∗ clamps of higher reliability (with a flexible input)

CLAMPS HARDWARE PRESSING FOR HOLLOW WIRE A6AP

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

compressing direction

126

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 20: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

T - thermodynamic method of application of copper on the contact surface

P - contact aluminum plate with a copper layer

NOMINATION:

For attaching two aluminum or steel-aluminum wires to hardware outputs. Clamps meet

TU 3449-016-52819896.

2A2A-300-1 T(P)

2A2A-300-4 T(Ï)

2A2A-500-1 T(P)

DesignationType of wire

by GOST 839-80Matrix

of pressing Weight,

kg

2A2A-300-1 T(P)A350, A400, AS300/39, AS300/48, AS300/66,

AS300/67, AS330/30, AS330/43, AS400/18, AS400/22A-40,5 2,35

2A2A-300-4 T(P)A350, A400, AS300/39, AS300/48, AS300/66, AS300/67,

AS330/30, AS330/43, AS400/18, AS400/22A-40,5 2,35

2A2A-500-1 T(P)A450, A500, A550, AS400/51, AS400/64, AS400/93,

AS450/56, AS500/26, AS500/27, AS500/64A-45 3,00

CLAMPS HARDWARE PRESSING TYPE 2A2A2A2A

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

127

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 21: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

2A4A-300/500-3 T(P)

2A4A-300/500-4 T(P)

DesignationL,

mm

Type of wire GOST 839-80 Matrixof pressing

Weight, kg A, AKP AS, ASKS, ASKP, ASK

2A4A-300-3 T(P) 100 350, 400300/39, 300/48, 330/30, 300/66,300/67, 330/43, 400/18, 400/22

A-40,5 2,6

2A4A-500-3 T(P) 120 450, 500, 550400/51, 400/64, 450/56, 400/93, 500/27, 500/64, 500/26, 300/204

A-45 2,97

2A4A-300-4 T(P) 100 350, 400300/39, 300/48, 330/39, 300/66

300/67, 330/43A-40,5 2,6

2A4A-500-4 T(P) 120 450, 500 ,550400/51, 400/64, 450/56, 400/93,

500/27, 500/64, 300/204A-45 2,97

CLAMPS HARDWARE PRESSING TYPE 2A4A 2A4A

T - thermodynamic method of application of copper on the contact surface

P - contact aluminum plate with a copper layer

NOMINATION:

For attaching two aluminum or steel-aluminum wires to hardware outputs when installing outdoor switchgear.

Clamps meet TU 3449-016-52819896-05.co

mpre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

128

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 22: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

2A6A-300/600-3 T(P)

2A6A-300/600-4 T(P)

DesignationType of wire by GOST 839-80 Matrix

of pressing

Dimensions, mm Weight, kgA, AKP AS, ASKS, ASKP, ASK L L

1

2A6A-300-3 T(P) 350, 400300/39, 300/48, 300/66,300/67,330/30,330/43, 400/18,400/22

A-40,5 400 100 4,1

2A6A-500-3 T(P) 450, 500, 550400/51, 400/64, 400/93, 450/56,500/26, 500/27, 500/64, 300/204

A-45 400 120 4,42

2A6A-600-3 T(P) 650 550/71, 600/72 A-51 440 140 5,5

2A6A-300-4 T(P) 350, 400300/39, 300/48, 300/66, 300/67,330/30, 330/43, 400/18, 400/22

A-40,5 400 100 4,1

2A6A-500-4 T(P) 450, 500, 550400/51, 400/64, 400/93, 450/56,500/26, 500/27,500/64, 300/204

A-45 400 120 4,42

2A6A-600-4 T(P) 650 550/71, 600/72 A-51 440 140 5,5

CLAMPS HARDWARE PRESSING TYPE 2A6A 2A6A

T - thermodynamic method of application of copper on the contact surface

P - contact aluminum plate with a copper layer

NOMINATION:

For attaching two aluminum or steel-aluminum wires to hardware outputs. Clamps meet

TU 3449-016-52819896-05.

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

129

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 23: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

2A4AP

Designation Type of wire by TU 16-505-397-72 Matrix of pressing Weight, kg

2A4AP-500-1 T(P) PA500 A-59 5,44

CLAMPS HARDWARE PRESSING FOR HOLLOW WIRE 2A4AP

T - thermodynamic method of application of copper

on the contact surface

P - contact aluminum plate

with a copper layer

NOMINATION:

For attaching two aluminumhollow wires to hardware outputs.

Clamps meetTU 3449-016-52819896-05.

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

130

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 24: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

Designation Fig, Type of wire Matrix

of pressing

L, mmWeight,

kgL L1

A

2A6AP-500-3 T(P) 1PA500 A-59 470 140 15 6,65

2A6AP-500-4 T(P) 2

2A6AP-640-1Á T(P) 1

PA640

A-74

530 200 12

9,80

2A6AP-640-2 T(P) 2 A-74 13,3

2A6AP-640-2Á T(P) 2 ASH-70 9,80

Fig. 1

Fig. 2

CLAMPS HARDWARE PRESSING TYPE 2A6AP 2A6AP

T - thermodynamic method of application of copper on the contact surface

P - contact aluminum plate with a copper layer

NOMINATION:

For attaching two aluminumhollow wires to hardware outputs.Clamps meetTU 3449-016-52819896-05.

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

131

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 25: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

NOMINATION:

For attaching three aluminum or steel-aluminum

wires to hardware outputs. Clamps meet

TU 3449-016-52819896-05.

Fig. 1

Fig. 2

CLAMPS HARDWARE PRESSING TYPE 3A2A 3A2A

T - thermodynamic method of application of copper

P - contact aluminum plate

with a copper layer

on the contact surface

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

compressing direction

compressing direction

132

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 26: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

Designation Fig.Type of wire by GOST 839-80 Matrix

of pressing

Dimensions, mm Weight, kgA, AKP AS, ASKS, ASKP, ASK L L

1L

2

3A2A-500-3 T(P)

1

450, 500, 550

400/51, 400/64, 400/93, 450/56, 500/26, 500/27,

500/64, 300/204A-45

400 400

120

5,75

3A2A-500-3B T(P) 6,06

3A2A-500-3A T(P)300 324

4,75

3A2A-500-3B T(P) 5,70

3A2A-600-3 T(P)650 550/71, 600/72 A-51 400 400 140

6,85

3A2A-600-3B T(P) 7,24

3A2A-500-4 T(P)2

450 400/51 A-45

400 400

120

6,06

3A2A-500-4B T(P) 5,38

3A2A-500-4A T(P)

3 300 324

5,38

3A2A-500-4V T(P) 5,13

3A2A-600-4B T(P) 650 550/71, 600/72 A-51 140 7,20

Ðèñ. 3

CLAMPS HARDWARE PRESSING TYPE 3A2A3A2A

NOMINATION:

For attaching three aluminum or steel-aluminum

wires to hardware outputs. Clamps meet

TU 3449-016-52819896-05.

T - thermodynamic method of application of copper

P - contact aluminum plate

with a copper layer

on the contact surface

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ionco

mpre

ssing d

irectio

n

133

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 27: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

3A4A-2 T(P)

3A4A-3 T(P), 3A4A-3A T(P)

DesignationType of wire by GOST 839-80 Matrix

of pressing L,

mmWeight,

kgA, AKP AS, ASKS, ASKP, ASK

3A4A-300-2 T(P) 350, 400300/39, 300/48, 300/66, 300/67,330/30, 330/43, 400/18, 400/22

A-40,5 100 7,15

3A4A-400-2 T(P)450, 500,

550400/51, 400/64, 400/93, 450/56,500/26, 500/27, 500/64, 300/204

A-45 120 7,54

3A4A-600-2 T(P) 650 550/71, 600/72 A-51 140 8,41

3A4A-300-3 T(P)350, 400

300/39, 300/48, 300/66, 300/67,330/30, 330/43, 400/18, 400/22

A-40,5 1008,08

3A4A-300-3A T(P) 7,87

3A4A-400-3 T(P) 450, 500, 550

400/51, 400/64, 400/93, 450/56,500/26, 500/27, 500/64, 300/204

A-45 1208,8

3A4A-400-3A T(P) 8,41

3A4A-600-3 T(P)650 550/71, 600/72 A-51 140

9,79

3A4A-600-3A T(P) 9,97

CLAMPS HARDWARE PRESSING TYPE 3A4A 3A4A

NOMINATION:

For attaching three aluminum or steel-aluminum

wires to hardware outputs. Clamps meet

TU 3449-016-52819896-05.

T - thermodynamic method of application of copper

P - contact aluminum plate

with a copper layer

on the contact surface

com

pre

ssin

g d

irect

ion

compressing direction

134

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 28: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

3A2AP-500-3 T(P), 3A2AP-500-3A T(P)

3A2AP-500-4 T(P), 3A2AP-500-4A T(P)

CLAMPS HARDWARE PRESSING TYPE P P P3A2A , 3AA , 4A6A3A2AP,3AAP, 4A6AP

NOMINATION:

For attaching three, four or five aluminum or steel-aluminum wires to hardware outputs. Clamps meet TU 3449-016-52819896-05.

T - thermodynamic method of application of copper

P - contact aluminum plate

with a copper layer

on the contact surfacecompressing direction

compressing direction

com

pre

ssin

g d

irect

ionco

mpre

ssing d

irectio

n

com

pre

ssin

g d

irect

ion

135

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 29: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

3AAP-500-1 T(P)

5A2AP-500-1 T(P)

CLAMPS HARDWARE PRESSING TYPE P P3AA , 4A6A 3AAP, 4A6AP

compressing direction

compressing directionprotective screen

EZ-750-2

NOMINATION:

For attaching three, four or five aluminum or steel-aluminum

wires to hardware outputs. Clamps meet

TU 3449-016-52819896-05.

T - thermodynamic method of application of copper

P - contact aluminum plate

with a copper layer

on the contact surface

136

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 30: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

4A6AP-640-1B T(P)

DesignationType of wire

by TU 16-505-397-72Matrix

of pressing

Dimensions, mm Weight, kgL L

1

3AAP-500-1 T(P)

PA500 A-59

- - 10,00

3A2AP-500-3 T(P)400 400

10,90

3A2AP-500-3A T(P) 8,30

3A2AP-500-4 T(P)400 420

9,33

3A2AP-500-4A T(P) 8,58

5A2AP-500-1 T(P) - - 32,70

4A6AP-640-1B T(P) PA640 A-74 530 - 27,00

CLAMPS HARDWARE PRESSING TYPE 4A6AP, 5A2AP 4A6AP, 5A2AP

NOMINATION:

For attaching three, four or five aluminum or steel-aluminum wires to hardware outputs. Clamps meet TU 3449-016-52819896-05.

T - thermodynamic method of application of copper

P - contact aluminum plate

with a copper layer

on the contact surface

com

pre

ssin

g d

irect

ion

com

pre

ssin

g d

irect

ion

137

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 31: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

NOMINATION:

For attaching cooper wire to

transformer hardware output, in the form of a smooth or

threaded cylindrical pin.Clamps meet

TU 34 27.10954-85.

Designation Fig.Dimensions, mm Weight,

kgB D d H L S

ASHM-3-21

85 22 10,5 58 17012

1,46

ASHM-4-2 87 26 15,5 62 175 1,58

ASHM-5-22 115

50 3080

230 18 2,89

ASHM-5-3 40 31 190

12

2,29

ASHM-12-1

1

85 24 M12 60

175

1,54

ASHM-16-187 26

M1662 1,6

ASHM-16-2 M16õ1,5

ASHM-20-189 28

M2064 1,71

ASHM-20-2 M20õ1,5

ASHM-22-1 91 30 M22õ1,5 66 1,75

ASHM-27-12

100 37 M27 76 1,9

ASHM-30-1 103 40 M30 80 2,0

Fig. 1

Fig. 2

CLAMPS HARDWARE PINNED TYPE ASHM ASHM

138

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

Page 32: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

T - thermodynamic (plasma) coating the contact surface

NOMINATION:

For fixing tubular bus-bar with diameter of 140/120 mm to hardware outputs. Clamps meet TU 34 13.10049-90.

AA-211T

AA-212

CLAMPS HARDWARE WITH EXPANSION BENDAA-211

protective screen

cap

hardware output

bus-bar

B-B

139

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

Page 33: CONTACT ARMATURE ARM.EU.pdf · GOST 839-80 Matrix of pressing Dimensions, mm Weight, kg B D d L L 1 OM-35-1 M35 A-13 13 16 10 101 60 0,168 OM-50-1 M50 Ñ-15 15 18 11 103 0,225 OM-70-1

AA-213T

Designation Weight, kg

AA-211T 32,5

AA-212 (Cap) 2,1

AA-213T 25,9

CLAMPS HARDWARE WITH EXPANSION BEND AA-213

T - thermodynamic (plasma) coating the contact surface

NOMINATION:

For fixing tubular bus-bar with diameter of 140/120 mm to hardware outputs. Clamps meet TU 34 13.10049-90.

hardware output

140

AIZ - registered trademark of enterprises "Insulators and accessories factory"R

www.insulators.ruwww.taiz.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@[email protected]

+7-495-7412286+7-4872-316844+375-222455264+7725-2-561716+370-62749925

AIZ, LitkarinoAIZ, Tula AIZ, Belarus AIZ, Kazakhstan AIZ, Lithuania