contactoare / contactors contactoare de comanda actionate ... · contactoare / contactors tip type...
TRANSCRIPT
Co
nta
cto
are
Co
nta
cto
rs
ELECTROAPARATAJ
contactoare / contactors
Tip
Type
ND=normal deschis/normally open
NI= normal inchis/normally closed
Ith (A)
Conventionalthermal current
Curent termicconventional
Tensiunea decomanda
Control voltageUc (V)
CodcomandaOrder code
ND; NI sunt combinatii de contacte/ ND; NI are contacts combinations:ND= contact normal deschis/ contact normally openNI= contact normal inchis/ contact normally closed
CC - 6A 4019
4019
4019
4019
4019
16 24; 48; 110; 220/230; 380/400;
500 c.c.
8ND
7ND 1NI
6ND 2NI
5ND 3NI
4ND 4NI
Contactoare de comanda actionate in curent continuu (tip CC)D.C. Drive contactors (type CC)
1
-standarde si normative/ standards and norms SR - EN 60947-5-1
10
10
1200
600
250
24/48; 72; 110; 170; 220 c.c.
6
(0,7....1,25) Uc
40(100)
1,0
M3,5
0,630
planul gaurilor de fixare: vertical/ fixing holes’ plan: upright
90%
1200
IP 00
-25....+40
6
5
Man.
Man/h
Man/h
m
V
V
A
%
kg
2mm
Man
o C
-durabilitate mecanica/ mechanical endurance
-frecventa maxima de conectare mecanica/ maximum mechanical
connection frequency
-durabilitate electrica/ electrical endurance
-frecventa max. conectare: sarcina/ max. connection frequency:
-temperatura ambianta/ ambiental temperatureo o
-umiditatea relativa medie la 20 C/ average relative humidity at 20 C
-altitudine maxima/ maximum height
-grad de protectie/ safety class
-tensiunea nominala de izolare/ insulating rated voltage
-tensiunea nominala de comanda a bobinei/ coil rated voltage
Command (Uc)
-curent nominal de utilizare/ operation rated current Ie
-domeniul de functionare/ operational field
-durata de conectare/ connection duration DC
-sectiunea cablului de racord/ connection cable cross section
-surub borna/ terminal screw
-pozitia normala de functionare/ normal operating position
-masa neta/ net weight*
* Poate sa varieze cu 20 gr. functie de tensiune (masa neta a bobinei)/ It may vary about 20gr. according to voltage (net weight of the coil)
Ue = 24V c.c.; L/R = 1ms
Date tehnice contactor tip CC-6A/ Technical data for type CC-6A contactor
10 25
5 20
ms
ms
-timp de inchidere/ time for closing
-timp de deschidere/ time for opening
ELECTROAPARATAJ
contactoare / contactors
Co
nta
cto
rsC
on
tac
toa
re
2
Date pentru comanda contactoare/ Data for ordering contactors:-denumire aparat/ apparatus name;-cod/ code;-combinatie de contacte/ contacts combination;-tensiunea de comnada (Uc)/ cue voltage;
Exemplu/ ExampleCC 6A; 4019; 6ND+2NI; 24 Vc.c.
Dimensiuni gabarit/ Overall dimensions
Contactoare de comanda actionatein curent continuu (tip CC)/ D.C. Drive contactors (type CC)
Scheme electrice/ Schemes
cod/ code 4019 - 5ND+3NI cod/ code 4019 - 4ND+4NI
cod/ code 4019 - 7ND+1NI cod/ code 4019 - 6ND+2NI
cod/ code 4019 - 8ND
contactoare / contactors
Tip
Type
ND=normal deschis/normally open
NI= normal inchis/normally closed
Tensiunea decomanda
Control voltage
Ith(A)
Conventionalthermal currentauxiliary contacts
Curent termicconventionalcontacte auxiliare
Uc (Vc.a.)
8166
Contactoare tripolare de forta actionate in curent alternativ (tip RG)A.C. Power three pole contactors (type RG)
CodcomandaOrder code
RG 16 62ND+2NI
RG 10 81676 24; 48; 110; 220/230; 380/400;
500*
50; 60Hz
2ND+2NI
RG 25
RG 40
8168
8169
10
10
24; 48; 110; 220/230; 380/400;
500*
50; 60Hz
2ND+2NI
2ND+2NI
ND; NI sunt combinatii de contacte auxiliare/ ND; NI; are auxiliary contacts combinations:ND= contact normal deschis/ contact normally openNI= contact normal inchis/ contact normally closed
*la cererea beneficiarului se livreaza si alte valori de tensiuni/ at the customer request, for other voltages too
RG 63 817010 24; 48; 110; 220/230; 380/400;
500* - 50; 60Hz
2ND+2NI
RG 125 8171A
8171B
16
10
24; 48; 110; 220/230; 380/400;
500* - 50; 60Hz
2ND+2NI
4ND+4NI
RG 200 8172A
8172B
16
10
24; 48; 110; 220/230; 380/400;
500* - 50; 60Hz
2ND+2NI
4ND+4NI
3
Co
nta
cto
are
Co
nta
cto
rs
ELECTROAPARATAJ
contactoare / contactors
Tip
Type
ND=normal deschis/normally open
NI= normal inchis/normally closed
Tensiunea decomanda
Control voltage
Contactoare tripolare de forta actionate in curent alternativ (tip RG)A.C. Power three pole contactors (type RG)
CodcomandaOrder code
RG 250 8173A (1
(1
(1
(18173B
16 24; 48; 110; 220/230; 380/400;
500* - 50; 60Hz
2ND+2NI
4ND+4NI
RG 400 8174A
8174B
16 24; 48; 110; 220/230; 380/400;
500* - 50; 60Hz
2ND+2NI
4ND+4NI
ND; NI sunt combinatii de contacte auxiliare/ ND; NI; are auxiliary contacts combinations:ND= contact normal deschis/ contact normally openNI= contact normal inchis/ contact normally closed
*la cererea beneficiarului se livreaza si alte valori de tensiuni/ at the customer request, for other voltages too
Ith(A)
Conventionalthermal currentauxiliary contacts
Curent termicconventionalcontacte auxiliare
Uc (Vc.a.)
ELECTROAPARATAJC
on
tac
tors
Co
nta
cto
are
4
-standarde si normative/ standards
and norms
SR - EN 60947-1; SR - EN 60947 - 4 - 1; SR - EN 60947 - 5 - 1; ST 31/2004
3000
660
25
2
0,25
20
30
2
0,25
25
45
2
0,5
35
60
2
0,5
63
100
2
0,5
80
160
4/2*
0,5
160
250
4/2*
0,5
250
250
4
0,5
315
500
4
0,5
500
(0,85....1,1) Uc
40(100)
1,0 1,5 2,5 4 6 16 50 70 120
M4 M4 M5 M5 M5 M8 M10 M12 M12
80%
2000
IP 00
-20....+55
5x106 2,5x106
0,35x10
1x10
0,35x10
300
600
300
6
6
6
600
120
1000
600
0,3x10 6
0,5x10 6
0,3x10 6
Man.
Man/h
Man/h
m
V
A
A
A
%
A
2mm
Man
o C
-durabilitate mecanica/ mechanical
endurance
-frecventa de conectare mecanica/
mechanical connection frequency
-durabilitate electrica/ electrical
endurance AC2
AC2
AC3
AC3
AC4
AC4
-frecventa max. conectare:
sarcina/ max. connection
frequency:
-temperatura ambianta/ ambiental
temperature
oaverage relative humidity at 20 C
o-umiditatea relativa medie la 20 C/
-altitudine maxima/ maximum
height
-grad de protectie/ safety class
-tensiunea nominala de izolare/
insulating rated voltage
-curent nominal de utilizare
contacte aux./ auxiliary contacts
operation rated current Ie
-curent termic conventional/
thermal conventional current Ith
-domeniul de functionare/
operational field
-durata de conectare/ connection
duration DC
-siguranta de protectie lenta/
slow safety fuse MPR(2
-sectiunea minima a cablului de
racord/ minimum connection of
joint wire
-surub borna/ terminal screw
* 4 pentru contacte 2ND+2NI si 2 pentru 4ND+4NI la variantele RG 125 si RG 200/ 4 for contacts 2ND+2NI and 2 for 4ND+4NI at RG 125 and RG 200 types
-380/400V
AC15A 380/400Vc.a.
DC13A 220/230Vc.c.
Date tehnice/ Technical data
contactoare / contactors
RG 10 RG 16 RG 25 RG 40 RG 63 RG 125 RG 200 RG 250 RG 400
5
Co
nta
cto
are
Co
nta
cto
rs
ELECTROAPARATAJ
contactoare / contactors
Date pentru comanda contactoare/ Data for ordering contactors:-denumire aparat/ apparatus name;-cod/ code;-frecventa nominala a retelei/ mains rated frequency-tensiunea de comanda a bobinei/ coil control voltage-varianta contacte auxiliary/ variant auxiliary contacts-executie (Normal, T3, Naval)/ performance (Normal, T3, Marine)
Exemplu/ Example:Contactor RG 200A; frecventa retelei 50Hz; tensiunea de comanda 220/230V; avand 4 contacte ND si 4 contacte NI in executie T3 se comanda/ Contactor RG 200A; mains frequency 50Hz; control voltage 220/230V; having 4ND contacts and 4 NI contacts in T3 execution is ordered:
RG 200; cod/code 8172B; 50Hz; 220/230V; 4ND+4NI; T3
-curent nominal motor/Pmotor
-coordonare cu dispozitivele de
-clasa de izolare a bobinei/
protectie la scurtcircuit/
coordination with shortcircuit
coil insulating class
safety devices
-regim/ rating AC2
-regim/ rating AC3
-regim/ rating AC4
A/KW 220/230V
220/230V
220/230V
A/KW 380/400V
380/400V
380/400V
A/KW 500V
A/KW 500V
A/KW 500V
motor rated current/Pmot.
11,6/3
11,5/5,5
8,9/5,5
11,6/3
11,5/5,5
8,9/5,5
4,9/1,1
5/2,2
3,8/2,2
tip/ type “2”
tip/ type “E”
5,1/3 6,5/4 8,9/5,5 11,9/7,5 16,7/11 28,5/18,5 33/22 64,5/45
6,6/3 8,5/4 11,5/5,5 15,5/7,5 22/11 37/18,5 44/22 85/45
6,2/1,5 8,7/2,2 11,6/3 15,3/4 20,6/5,5 39,2/11 43,8/12,5 75,2/22
11,9/7,5 16,7/11 28,5/18,5 44/30 79/55 156/110 186/132 310/220
15,5/7,5 22/11 37/18,5 60/30 105/55 205/110 245/132 408/220
20,6/5,5 20,6/5,5 39,2/11 64,9/18,5 101/30 181/55 245/75 358/110
11,9/7,5 16,7/11 22,5/15 28,5/18,5 44/30 64,5/45 79/55 156/110
15,5/7,5 22/11 30/15 37/18,5 60/30 85/45 105/55 205/110
15,3/4 20,6/5,5 27,4/7,5 27,4/7,5 52,6/15 75,2/22 101/30 181/55
0,370 0,415 1,000 1,000 1,550 5,200 11,300 18,200 29,300kg-masa neta/ net weight
1: A=2ND+2NI; B=4ND+4NI2: Valorile sigurantelor s-au specificat pentru curentii nominali ai motoarelor, presupunand pentru pornirea directaun timp de accelerare de 5 sec. In cazul unor motoare care au curenti nominali mai mari, timp de accelerare mai lungsau, curenti de pornire mai mari, se vor alege sigurante de valori mai mari. Valorile maxime utilizabile sunt determinatede releele termice ale motoarelor, respectiv de aparatele de comutatie. Sigurantele vor fi MPR/The value of the fuses were specified for the rated current of the motor, assuming for direct start-up an accelerationtime of 5 sec. In case of motors with greater rated currents, the acceleration time is longer or greater starting currents,fuses with greater values will be chosen. Maximum utilization values are determined by motors’ thermal relays,switching apparatus. Safety fuses type MPR.3. Curentul nominal al motoarelor se refera la motoare cu o turatie de 1500rot/min./ Motor rated current is referringto motors’ speed of 1500rot/min.4. Protectie cu intreruptor automat/ Protection with automatic switch.
Date tehnice/ Technical data
RG 10 RG 16 RG 25 RG 40 RG 63 RG 125 RG 200 RG 250 RG 400
planul gaurilor de fixare: vertical/ fixing holes’ plan: upright-pozitia normala de functionare/
normal operating position
(3
(4
ELECTROAPARATAJC
on
tac
tors
Co
nta
cto
are
6
contactoare / contactors
Dimensiuni gabarit/ Overall dimensions
Contactoare tripolare de forta actionate in curent alternativ (tip RG)/A.C. Force three pole contactors (type RG)
RG 10 - 16
RG 25 - 40
RG 63
7
Co
nta
cto
are
Co
nta
cto
rs
ELECTROAPARATAJ
contactoare / contactors
Dimensiuni gabarit/ Overall dimensions
Contactoare tripolare de forta actionate in curent alternativ (tip RG)/A.C. Force three pole contactors (type RG)
RG 125 - 200
RG 250; 400
RG 125
RG 200
RG 250
RG 400
8171
8172
8173
8174
150
190
214
245
170
198
239
260
180
210
261
310
130
160
180
213
150
170
200
220
32
42
47
55
35
35
34
39
141
163
204
243
7
10,5
13
13
Tip/ Type Cod/ Code a b c d e f g h
ELECTROAPARATAJC
on
tac
tors
Co
nta
cto
are
8
contactoare / contactors
Scheme electrice/ Schemes
RG 10 - 16
RG 25 - 40
RG 63
RG 125 - 200; 250; 400;var. 4ND+4NI
RG 125; 200; 250; 400var. 2ND+2NI
9
Co
nta
cto
are
Co
nta
cto
rs
ELECTROAPARATAJ
contactoare / contactors
Tip
Type
ND=normal deschis/normally open
NI= normal inchis/normally closed
Tensiunea decomanda
Control voltage
Contactoare tripolare de forta actionate in curent continuu (tip TCC)D.C. Three poles power frontal contactors (type TCC)
CodcomandaOrder code
TCC 10 40186 24; 48; 110; 220/230*Vc.c.2ND+2NI
TCC 32 401410 24; 110*Vc.c.2ND+1NI+1NI**
ND; NI sunt combinatii de contacte/ ND; NI; are contacts combinations:ND= contact normal deschis/ contact normally openNI= contact normal inchis/ contact normally closed
*la cererea beneficiarului se livreaza si alte valori de tensiuni/ at the customer request, for other voltages too** pentru rezistenta aditionala/ for dropping resistor
TCAC 40 401310 24; 48; 110; 220/230*Vc.c.2ND+2NI
Ith(A)
Conventionalthermal currentauxiliary contacts
Curent termicconventionalcontacte auxiliare
Uc (Vc.c.)
Date pentru comanda contactoare/ Data for ordering contactors:-denumire aparat/ apparatus name;-cod/ code;-tensiunea de comanda a bobinei/ coil control voltage-varianta contacte auxiliary/ variant auxiliary contacts-executie (Normal, T3, Naval)/ performance (Normal, T3, Marine)
Exemplu/ Example:Contactor TCC 10A; cod 4018; tensiunea de comanda; cu 2 contacte auxiliare ND si 2 contacte auxiliare NI in executie T3 se comanda/ Contactor TCC 10A; code 4018; control voltage; having 2ND auxiliary contacts and 2NI auxiliary contacts in T3 execution is ordered:
TCC 10A; 4018; 2ND+2NI; 220/230Vc.c.; T3
ELECTROAPARATAJC
on
tac
tors
Co
nta
cto
are
10
contactoare / contactors
0,680 2,400 2,300kg-masa neta/ net weight
-standarde si normative/ standards and norms SR-EN60947-1; SR-EN60947-4-1; SR-EN60947-5-1; ST31/2004; ST5/2001
3000
10 32 40
2
0,25
20 35 63
(0,85....1,1) Uc
40(100)
1,5 4 4
M3,5 M5 M5
planul gaurilor de fixare: vertical/ fixing holes’ plan: upright
80%
2000
IP 00
250 500 500
-20....+40
1x10
5x10
6
5
600
Man.
Man/h
Man/h
m
Vc.a.
A
A
A
%
(2
A
2mm
Man
o C
-durabilitate mecanica/ mechanical endurance
-frecventa de conectare mec./ mechanical connection frequency
-durabilitate electrica/ electrical endurance
-frecventa max. conectare: sarcina/ load
maximum connection frequency
-temperatura ambianta/ ambiental temperature
oo-umiditatea relativa medie la 20 C/ average humidity at 20 C
-altitudine maxima/ maximum height
-grad de protectie/ safety class
-tensiunea nominala de izolare/ insulating rated voltage Ui
-curent nominal de utilizarecontacte auxiliare/ auxiliary contacts
operation rated current Ie
-curent conventional termic/ thermal conventional current Ith
-domeniul de functionare/ operation field
-durata de conectare/ connection duration DC
-siguranta de protectie lenta/ slow safety fuse MPR
-sectiunea min. a cablului de racord/ min. connection of joint wire
-surub borna/ terminal screw
-pozitia normala de functionare/ normal operating position
-380/400V
AC15 380/400Vc.a.
DC13 220/230Vc.c.
Date tehnice/ Technical data
TCC 10 TCC 32 TCAC 40
-curent nominal motor-Pmotor/ motor rated current-Pmot.
-coordonare cu dispozitivele de protectie la scurtcircuit/
-clasa de izolare a bobinei/ coil insulating class
coordination with shortcircuit safety devices
-regim/ rating AC3
A/KW 220/230V
A/KW 380/400V
A/KW 500V
11,6/3 20,6/5,5 39,2/11
11,5/5,5 22/11 37/18,5
8,9/5,5 16,7/11 28,5/18,5
tip/ type “2”
tip/ type “E”
1. Valorile sigurantelor s-au specificat pentru curentii nominali ai motoarelor, presupunand pentru pornirea directa un timp de accelerare de 5 sec. In cazul unor motoare care au curenti nominali mai mari, timp de accelerare mai lung sau, curenti de pornire mai mari, se vor alege sigurante de valori mai mari. Valorile maxime utilizabile sunt determinate de releele termice ale motoarelor, respectiv de aparatele de comutatie. Sigurantele vor fi MPR/ The value of the fuses were specified for the rated current of the motor, assuming for direct start-up an acceleration time of 5 sec. In case of motors with greater rated currents, the acceleration time is longer or greater starting currents, fuses with greater values will be chosen. Maximum utilization values are determined by motors’ thermal relays, switching apparatus. Safety fuses type MPR.2. Curentul nominal al motoarelor se refera la motoare cu o turatie de 1500rot/min./ Motor rated current is referring to motors’ speed of 1500rot/min.
11
Co
nta
cto
are
Co
nta
cto
rs
ELECTROAPARATAJ
contactoare / contactors
TCC 10
TCC 32
TCAC 40
Contactoare tripolare de forta actionate in curent continuu (tip TCC)D.C. Three poles power frontal contactors (type TCC)
Dimensiuni gabarit/ Overall dimensions
ELECTROAPARATAJC
on
tac
tors
Co
nta
cto
are
12