contents hoods/housings with metric thread page - prosoft · hoods/housings with metric thread page...
TRANSCRIPT
31.01
Han HoodsHousings
Contents
Hoods/Housings with metric thread Page
Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.02
Han® Hoods and Housings with metric thread . . . . . . . . . . . . . . . . . . . . . . . 31.03
Standard Hoods/Housings size Han A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.10
Standard Hoods/Housings size Han B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.16
– with 2 levers on the housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.18
– with 1 lever on the housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.20
– with 2 levers on the hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.22
– with central locking lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.23
– for 2 inserts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.24
Han® M Hoods/Housings for harsh environmental requirements . . . . . . . . . 31.26
Han® HPR Hoods/Housings pressure tight and EMI resistant . . . . . . . . . . . 31.32
Han® EMC Hoods/Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.35
Han® EMC/B Hoods/Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.37
Hoods/Housings for special applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.39
Note: Han® hoods and housing with NPT-thread also available by HARTING Inc. of North America, USA
Enclosure type acc. UL 50: NEMA 4/12(File E235076)
31.02
Han HoodsHousings
Technical characteristics
Han® 3 A Hoods/Housings thermoplasticMaterial Polycarbonate RAL 7032Locking element Polyamide RAL 7032Hoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Flammability acc. to UL 94 V 0Degree of protection acc. to DIN EN 60 529for coupled connector IP 67
Han® 3 A Hoods/Housings metalMaterial Die cast zinc alloySurface powder-coated
RAL 7037 (grau)Locking element Steel, zinc platedHoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 44
IP 67 is achieved with sealscrew 09 20 000 9918
Han® M Hoods/Housings for harsh environmental requirementsMaterial Die cast aluminium alloySurface- Priming Chromated- Top Coat Epoxy powder paint (black)Locking element V2A SteelHoods/Housings seal FPMLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 65Size Han® 3 A IP 44
IP 67 is achieved with seal screw09 20 000 9918
Han® Standard Hoods/HousingsMaterial Die cast aluminium alloySurface powder-coated RAL 7037 (grey)Locking element V2A Steel / Steel, zinc plated /
Han-Easy Lock®
Hoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 65
Han® HPR Hoods/Housings pressure tightand highly EMI resistant
Material corrosion resistant die cast aluminium alloy
Surface- Top Coat Epoxy powder paint (black)Locking element- Screw locking M 6
- Material V2A Steel- Tightening torque 4 Nm
- Toggle locking- Material V2A Steel
Hoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 68
Han® EMC Hoods/Housings for high shieldingMaterial Die cast aluminium alloySurface conductive finishLocking element V2A Steel / Steel, zinc platedHoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 65Size Han® 3 A IP 44
IP 67 is achieved with seal screw09 20 000 9918
Han® EMC/ B Hoods/Housings for high shieldingMaterial- hoods/housings Die cast aluminium alloy- shielded frames Die cast zinc alloySurface- hoods/housings electrical conductive- shielded frames electrical conductiveLocking element Han-Easy Lock®
Hoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCEnclosure type acc. to UL 50 NEMA 4/12Degree of protection acc. to DIN EN 60 529 for coupled connector IP 65
31.03
M 20M 25M 32M 40M 50
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 mm
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 mm
M 40M 40
M 32M 32
M 25M 25
M 20M 20
M 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 mm1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 mm
Pg 11Pg 13.5Pg 16Pg 21Pg 29Pg 36Pg 42
Pg
PG 29PG 29
PG 29
PG 21PG 21
PG 16PG 16
PG 13.5
PG 11PG 11
Han HoodsHousings
Han® Hoods and Housings with Metric Cable Entries
The Cross Reference table showsthe correlation between the PGversions and the new metric types.
Please notice that the maximumcable diameter will be reduced by thenew metric cable glands.
Below is shown the cable range of metric glands:
The reason for the new product offerings is the publication of the international DIN EN 50262 metric threadspecification.
The existing PG series, PG 7 to PG 48 will be, in time, replaced by the metric series M 12 to M 63.
The adoption of metric threads considerably simplifies the understanding and specification of glands as theproduct type description contains the thread dimension. E.g. M 20 refers to 20 mm thread diameter.
To differentiate the metric threaded hoods and housings from the previous PG versions metric types will be marked with M .
CrCross Refoss ReferenceerenceMetric
31.10
A B
C
A 09 20 003 54071)3)1)
09 20 003 54082)3)4)
B 09 20 003 54452)1)1)
09 20 003 54461)1)1)
09 20 003 54472)3)4)
C 09 20 003 54481)1)1)
09 20 003 54492)4)1)
Hoods/Housings thermoplastic Size 3 A
Identification Part No. M Drawing Dimensions in mm
Hoo
ds
Hoodsside-entry grey
19 20 003 0620 20
black19 20 003 0627 20
Protection coversfor hoods
09 20 003 54421)
09 20 003 54412)
grey19 20 003 0420 20
black19 20 003 0427 20
Hoodstop-entry
Stock items in bold type1) for mounted male insert2) for mounted female insert
3) for metal housings and cable to cable hoods also4) for mounted Han-Brid® male and female insert
Han HoodsHousings
Hou
sing
s
Housings bulkhead mounting
grey09 20 003 0320 –
black09 20 003 0327 –
grey09 20 003 0820 –
black09 20 003 0827 –
Housingssurface mounting1 side-entry grey
19 20 003 0220 20
black19 20 003 0227 20
Hoods cable to cable
grey19 20 003 0720 20
black19 20 003 0727 20
Panel cut out 22 x 22 mm
Panel cut out 22 x 22 mm
for housings
for hoods cable to cable
Protection covers
31.11
09 20 003 0801
09 20 003 0301
19 20 003 1250 20
19 20 003 1252 20
19 20 003 1150 20
19 20 003 1750 20
09 20 003 54221)
09 20 003 54212)
09 20 003 54261)
09 20 003 54252)
09 20 003 54281)
09 20 003 54272)
09 20 003 03051)
09 20 003 03062)
19 20 003 1640 20
19 20 003 1440 20
Han HoodsHousings
Hoods/Housings with metric thread Size 3 A
Metal
Identification Part No. M Drawing Dimensions in mm
1) for mounted male insert 2) for mounted female insert Stock items in bold type
Hoo
dsH
ousi
ngs
Panel cut out22 x 22 mm
Panel cut out22 x 22 mm
Housingsbulkhead mounting
Housingsurface mounting
1 side-entry
bottom closed
Housingscrew mounting
Hood cable to cable
Protection coversfor hoods
Protection coversfor housings
for hoods cable to cable
with fixed cover
without sealing
with sealing
Hoodside-entry
Hoodtop-entry
31.12
Han HoodsHousings
Hoodsside-entry
19 20 010 1540 20
19 20 010 0546 25
Hoodstop-entry
19 20 010 1440 20
19 20 010 0446 25
Protection coversfor hoods
09 20 010 5423
Protection coversfor housings
09 20 010 5425
Hoo
ds
Housingsbulkhead mounting
09 20 010 0301 –
with thermo-plastic cover
09 20 010 0321 –
Housingssurface mounting
1 side-entry 19 20 010 02511) 1 x 25
2 side- 19 20 010 0290 2 x 20entries
with thermo-plastic cover
19 20 010 0295 2 x 20
Hou
sing
sStandard Hoods/Housings with metric thread Size 10 A
with 1 lever on the housing
Part No.
Identification Low construction High construction M Drawing Dimensions in mm
1) only metal glands Stock items in bold type
31.13
Han HoodsHousings
Hoodsside-entry
19 20 016 1540 20
19 20 016 0546 25
Hoodstop-entry
19 20 016 1440 20
19 20 016 0446 25
Hoo
ds
Housingsbulkhead mounting
09 20 016 0301 –
with thermo-plastic cover
09 20 016 0321 –
Housingssurface mounting
1 side-entry 19 20 016 02511) 1 x 25
2 side- 19 20 016 0290 2 x 20entries 19 20 016 0291 2 x 25
with thermo-plastic cover
19 20 016 0295 2 x 20
Hou
sing
sStandard Hoods/Housings with metric thread Size 16 A
with 1 lever on the housing
Part No.
Identification Low construction High construction M Drawing Dimensions in mm
1) only metal glands Stock items in bold type
Protection coversfor hoods
09 20 016 5423
Protection coversfor housings
09 20 016 5425
31.14
Han HoodsHousings
Hoodsside-entry
19 20 032 1521 25
19 20 032 0527 32
Hoodstop-entry
19 20 032 0426 2519 20 032 0427 32
Protection cover
09 20 032 5401 –
Protection cover
09 20 032 5405
Hoo
ds
Housingbulkhead mounting
09 20 032 0301 –
Housingssurface mounting
1 side-entry 19 20 032 0231 1 x 25
19 20 032 0232 1 x 32
2 side- 19 20 032 0272 2 x 32entries
Hou
sing
sStandard Hoods/Housings with metric thread Size 32 A
with 2 levers on the housing for 2 inserts
Part No.
Identification Low construction High construction M Drawing Dimensions in mm
Stock items in bold type
Panel cut out
Blind wayfor one cable entry
31.15
19 20 032 0537 32
19 20 032 1531 25
19 20 032 0437 32
09 20 032 0302 –
19 20 032 0226 1 x 25
Han HoodsHousings
Hoodsside-entry
Hoodstop-entry
Hoo
ds
Housingsbulkhead mounting
with thermo-plastic cover
1 side-entry with thermo-plastic cover
Housingssurface mountingH
ousi
ngs
Standard Hoods/Housings with metric thread Size 32 A
with 2 levers on the housing for 2 inserts
Part No.
Identification Low construction High construction M Drawing Dimensions in mm
Stock items in bold type
Panel cut out
1) Blind way for one cable entry
31.16
Han HoodsHousings
Standard Hoods with metric thread Size 6 B
with 1 lever on the housing
Stock items in bold type
Part No.
Identification Low construction High construction M Drawing Dimensions in mm
Hoodsside-entry
19 30 006 1540 20
19 30 006 1541 25
19 30 006 0546 25
19 30 006 0547 32
Hoodstop-entry
19 30 006 1440 20
19 30 006 0446 25
19 30 006 0447 32
Hoo
ds
Protection coversfor hoodsmetal
09 30 006 5401
09 30 006 5423
Protection coverfor cable to cable hood
metal 09 30 006 5427
Hoodscable to cable
h
19 30 006 1750 20 42.5
19 30 006 0756 25 72.5
31.17
Han HoodsHousings
Standard Housings with metric thread Size 6 B
with 1 lever on the housing
Part No.
Identification Low construction High construction M Drawing Dimensions in mm
Hou
sing
s
1) Blind way for one cable entry
Panel cut out 48 x 35 mm
a b hLow construction 40 52 54High construction 45 57 74
Housingsbulkhead mounting
09 30 006 0301 –
with thermo-plastic cover
09 30 006 0302 –
with metalcover
09 30 006 0318 –
Housingssurface mounting
19 30 006 1250 1 x 20
19 30 006 1290 2 x 2019 30 006 0291 2 x 2519 30 006 0292 2 x 32
with thermo- with thermo-plastic cover plastic cover
19 30 006 1255 1 x 2019 30 006 1295 2 x 20
19 30 006 0296 2 x 2519 30 006 0297 2 x 32
with withmetal cover metal cover
19 30 006 2255 1 x 2019 30 006 2295 2 x 20
19 30 006 7296 2 x 25
Protection coversmetal
09 30 006 5404
09 30 006 5425
Stock items in bold type
31.18
*
*
Han HoodsHousings
Standard Hoods with metric thread Size B
with 2 levers on the housing
Part No.
Identification Size Low construction High construction M Drawing Dimensions in mm
Stock items in bold type
Low con- High con-Size a struction struction
h h
10 B 73.0 57.0 72
16 B 93.5 62.5 76
24 B 120.5 62.5 76
Low con- High con-Size a struction struction
h h
10 B 73.0 45 72
16 B 93.5 45 76
24 B 120.5 55 76
Size a b c
10 B 74.0 78.5 28.5
16 B 94.5 99.0 44.0
24 B 121.0 125.5 44.0
Hoodsside-entry
10 19 30 010 1520 2010 19 30 010 1521 2510 19 30 010 0527 32
16 19 30 016 1521 2516 19 30 016 1522 19 30 016 0527 3216 19 30 016 0528 40
24 19 30 024 1521 2524 19 30 024 1522 19 30 024 0527 3224 19 30 024 0528 40
Hoodstop-entry
10 19 30 010 1420 2010 19 30 010 1421 2510 19 30 010 0427 32
16 19 30 016 1421 2516 19 30 016 1422 19 30 016 0427 3216 19 30 016 0428 40
24 19 30 024 1422 19 30 024 0427 3224 19 30 024 0428 40
Protection coversthermoplastic/metal
10 09 30 010 540110 09 30 010 5423
16 09 30 016 540116 09 30 016 5422
24 09 30 024 540124 09 30 024 5422
* 10 B: housing width 43 mm
* 10 B: housing width 43 mm
31.19
10 09 30 010 0301 –
16 09 30 016 0301 –
24 09 30 024 0301 –
10 19 30 010 1230 1 x 2010 19 30 010 1231 19 30 010 0231 1 x 2510 19 30 010 1270 2 x 2010 19 30 010 0271 2 x 2510 19 30 010 0272 2 x 32
16 19 30 016 1231 1 x 2516 19 30 016 0232 1 x 3216 19 30 016 1271 19 30 016 0271 2 x 2516 19 30 016 0272 2 x 3210 19 30 016 0273 2 x 40
24 19 30 024 1231 1 x 2524 19 30 024 0232 1 x 3224 19 30 024 1271 2 x 2524 19 30 024 0272 2 x 3224 19 30 024 0273 2 x 40
10 09 30 010 540710 09 30 010 5425
16 09 30 016 540516 09 30 016 5425
24 09 30 024 540524 09 30 024 5425
10 19 30 010 1730 2010 19 30 010 0736 2510 19 30 010 0737 32
16 19 30 016 1731 19 30 016 0736 2516 19 30 016 1732 19 30 016 0737 32
24 19 30 024 1732 19 30 024 0737 3224 19 30 024 0738 40
10 09 30 010 5427
16 09 30 016 5426
24 09 30 024 5426
10 B 83 93 60 x 35
16 B 103 113 82 x 35
24 B 130 140 108 x 35
Standard Housings with metric thread Size B
with 2 levers on the housing
Part No.
Identification Size Low construction High construction M Drawing Dimensions in mm
Size a b Panel cut out
Housings bulkhead mounting
Han HoodsHousings
10 Blow 82 94 40 52 54
high 82 94 45 57 81
16 Blow 105 117 45 57 56
high 105 117 45 57 81
24 Blow 132 144 45 57 56
high 132 144 45 57 81
10 Blow 73,0 47.5
high 73,0 74.5
16 Blow 93.5 47.5
high 93.5 78.5
24 Blow 120,0 57.5
high 120,0 78.5
Size b c
Housings surface mounting
Protection coversfor housingsbulkhead and surface mounting
Thermoplastic/metal
Hoodscable to cable
Stock items in bold type
con-Size a b c d hstruction
Size a b
10 B 74,0 78.5
16 B 94.5 99,0 ,0
24 B 121,0 125.5 ,0
con-Size a hstruction
10 B 78.5 28.5
16 B 99,0 44,0
24 B 125.5 44,0
Protection coversfor hoodscable to cable
Blind way for one cable entry
31.20
10 19 30 010 1540 2010 19 30 010 1541 2510 19 30 010 0547 32
16 19 30 016 1541 2516 19 30 016 1542 19 30 016 0547 3216 19 30 016 0548 40
24 19 30 024 1541 2524 19 30 024 1542 19 30 024 0547 3224 19 30 024 0548 40
10 19 30 010 1440 2010 19 30 010 1441 2510 19 30 010 0447 32
16 19 30 016 1441 2516 19 30 016 1442 19 30 016 0447 3216 19 30 016 0448 40
24 19 30 024 1442 19 30 024 0447 3224 19 30 024 0448 40
*
*
Standard Hoods with metric thread Size B
with 1 lever on the housing
Part No.
Identification Size Low construction High construction M Drawing Dimensions in mm
Han HoodsHousings
Hoodsside-entry
Hoodstop-entry
Stock items in bold type
Low con- High con-Size a struction struction
h h
10 B 73.0 57.5 72
16 B 93.5 62.5 76
24 B 120.5 62.5 76
Low con- High con-Size a struction struction
h h
10 B 73.0 45 72
16 B 93.5 45 76
24 B 120.5 55 76
* 10 B: housing width 43 mm
* 10 B: housing width 43 mm
31.21
*
Han HoodsHousings
Standard Hoods/Housings with metric thread Size B
with 1 lever on the housing
Part No.
Identification Size Low construction High construction M Drawing Dimensions in mm
Housingsbulkhead mounting 10 09 30 010 0305 –
16 09 30 016 0307 –24 09 30 024 0307 –
with thermo-plastic cover
10 09 30 010 0303 –16 09 30 016 0306 –24 09 30 024 0304 –
with metal cover
10 09 30 010 0318 –16 09 30 016 0318 –24 09 30 024 0318 –
Size a b Panel cut out
10 B 83 93 60 x 35
16 B 103 113 82 x 35
24 B 130 140 108 x 35
Stock items in bold type
Housingssurface mounting 10 19 30 010 1250 1 x 20
10 19 30 010 1290 2 x 2010 19 30 010 0291 2 x 2510 19 30 010 0292 2 x 3216 19 30 016 1251 1 x 25
19 30 016 0252 1 x 3216 19 30 016 1291 19 30 016 0291 2 x 2516 19 30 016 0292 2 x 3224 19 30 024 1251 1 x 2524 19 30 024 1291 2 x 2524 19 30 024 0292 2 x 32
with thermo- with thermo-plastic cover plastic cover
10 19 30 010 1255 1 x 2010 19 30 010 1295 2 x 2010 19 30 010 0296 2 x 2510 19 30 010 0297 2 x 3216 19 30 016 1256 1 x 2516 19 30 016 1296 2 x 2516 19 30 016 0297 2 x 3224 19 30 024 1256 1 x 2524 19 30 024 1296 2 x 2524 19 30 024 0297 2 x 32
with metal with metal cover cover
10 19 30 010 2295 2 x 2010 19 30 010 7296 2 x 2516 19 30 016 2296 2 x 2516 19 30 016 7297 2 x 3224 19 30 024 2296 2 x 2524 19 30 024 7297 2 x 32
Hoodcable to cable
10 19 30 010 1750 2010 19 30 010 0756 25
16 19 30 016 1751 2516 19 30 016 1752 19 30 016 0757 32
24 19 30 024 1752 19 30 024 0757 32
1) Blind way for one cable entry
Size Construction a b c d
10 Blow 82 94 40 52high 82 94 45 57
16 B low/high 105 117 45 5724 B low/high 132 144 45 57
Size Construction e f g h
10 Blow 18 22 67 54high 18 20 65 81
16 Blow 18 20 65 56high 18 20 65 81
24 Blow 18 20 65 56high 18 20 65 81
* high construction 16 B, 24 B: without mol-ded adapter and housing width 45 mm
h hSize a b low high
10 B 73.5 89 47.5 74.5
16 B 93.5 110 47.5 78.5
24 B 120.5 137 57.5 78.5
31.22
Han HoodsHousings
Standard Hoods/Housings with metric thread Size B
with 2 levers on the housing
Part No.
Identification Size Low construction High construction M Drawing Dimensions in mm
Hoodsside-entry 10 19 30 010 1530 20
10 19 30 010 0537 32
16 19 30 016 1531 2516 19 30 016 0537 3216 19 30 016 0538 40
24 19 30 024 1531 2524 19 30 024 0537 3224 19 30 024 0538 40
Hoodstop-entry 10 19 30 010 1430 20
10 19 30 010 0436 25
16 19 30 016 1431 2516 19 30 016 1432 19 30 016 0437 3216 19 30 016 0438 40
24 19 30 024 1432 19 30 024 0437 3224 19 30 024 0438 40
Hoo
ds
Housingsbulkhead mounting with thermo-
plastic cover
10 09 30 010 030216 09 30 016 030224 09 30 024 0302
with metal cover
10 09 30 010 031716 09 30 016 031724 09 30 024 0317
Hou
sing
s
Panel cut out
Hoodsflat cableentry
16 09 30 016 4431
Size a b c
10 83 93 60
16 103 113 82
24 130 140 108
Low HighSize a construction construction
h c h c
10 73.5 57.5 43 72 43
16 93.5 62.5 45 76 45
24 120.5 62.5 45 76 45
1) Blind way for one cable entry
Low HighSize a construction construction
h c h c
10 73.5 45 43 72 43
16 93.5 45 45 76 45
24 120.5 55 45 76 45
Housingssurface mounting
with thermo- with thermo-plastic cover plastic cover
10 19 30 010 1225 1 x 2010 19 30 010 1265 2 x 2010 19 30 010 0266 2 x 25
16 19 30 016 1226 1 x 2516 19 30 016 1266 2 x 2516 19 30 016 0267 2 x 32
24 19 30 024 1226 1 x 2524 19 30 024 1266 2 x 2524 19 30 024 0267 2 x 32
Stock items in bold type
a = see above
Con-Size a b c d f g hstruction
10low 82 94 40 52 22 67 54high 82 94 45 57 20 65 81
16low 105 117 45 57 20 65 56high 105 117 45 57 20 65 81
24low 132 144 45 57 20 65 56high 132 144 45 57 20 65 81
31.23
*
6 19 30 006 0586 25
10 19 30 010 0586 25
16 19 30 016 0586 2516 19 30 016 0587 32
24 19 30 024 0586 2524 19 30 024 0587 3224 19 30 024 0588 40
16 19 30 016 0487 32
24 19 30 024 0487 32
10 09 30 010 0381
16 09 30 016 0381
24 09 30 024 0381
16 19 30 016 0282 2 x 32
24 19 30 024 0282 2 x 32
16 105 117 81
24 132 144 81
Size a b h
10 83 93 60 x 35
16 103 113 82 x 35
24 130 140 108 x 35
Size a b Panel cut out
Hoods/Housings with metric thread Size B
Identification Size Part No. M Drawing Dimensions in mm
Hou
sing
sH
oods
Stock items in bold type
Han HoodsHousings
with central locking lever
Hoodsside-entry
Hoodstop-entry
Housingsbulkhead mounting
Housingssurface mounting
10 73.0 70
16 93.5 76
24 120.0 87
Size a b
16 93.5 76
24 120.0 87
Size a b
* 10 B: housing width43 mm
31.24
19 30 032 0527 3219 30 032 0528 4019 30 032 0529 50
09 30 032 0301 –
19 30 032 0427 3219 30 032 0428 4019 30 032 0429 50
19 30 032 0232 1 x 3219 30 032 0272 2 x 3219 30 032 0273 2 x 40
19 30 032 0738 40
09 30 032 5425 –
09 30 032 5420 –
Han HoodsHousings
Standard Hoods/Housings with metric thread Size 32 B
with 2 levers on the housing for 2 inserts
Identification Part No. M Drawing Dimensions in mm
Hoodsside-entry
Housingbulkhead mounting
Hou
sing
sH
oods
Hoodstop-entry
Housingssurface mounting
Hoodcable to cable
Protection covers
for housings
Panel cut out
Protection coverfor hoods
Stock items in bold type
31.25
Han HoodsHousings
Standard Hoods/Housings with metric thread Size 48 B
with 1 lever on the housing for 2 inserts
Identification Part No. M Drawing Dimensions in mm
Hoodsside-entry
19 30 048 0548 4019 30 048 0549 50
Housingsbulkhead mounting
with thermo-plastic cover
09 30 048 0301 –
with metal cover
09 30 048 0317 –
Hou
sing
sH
oods
Hoodstop-entry
19 30 048 0448 4019 30 048 0449 50
Housingssurface mounting 2 side-entries
19 30 048 0292 2 x 3219 30 048 0293 2 x 40
with thermo-plastic cover
19 30 048 0298 2 x 40
1) Blind grommet
Panel cut out
Stock items in bold type
31.26
09 37 003 0801
09 37 003 0301
19 37 003 1250 20
19 37 003 1750 20
09 37 003 54021)
09 37 003 54012)
09 37 003 54052)
09 37 003 54061)
19 37 003 1640 20
19 37 003 1150 20
19 37 003 1440 20
Han HoodsHousings
Hoods/Housings Han® M with metric thread Size 3 A
for harsh environmental requirements
Identification Part No. M Drawing Dimensions in mm
1) for mounted male insert 2) for mounted female insert Stock items in bold type
Hoo
dsH
ousi
ngs
Housings bulkhead mounting
Housingsurface mounting 1 side-entry
Hood cable to cable
Housing screw mounting
Protection coversfor hoods
Protection coverfor housings
Panel cut out 22 x 22 mm
Panel cut out22 x 22 mm
Hoodsside-entry
Hoodstop-entry
31.27
19 37 006 1540 19 37 006 0545 2019 37 006 0546 25
19 37 006 1440 19 37 006 0445 2019 37 006 0446 25
09 37 006 5405
09 37 006 0301 –
09 37 006 0318 –
19 37 006 1290 2 x 20
19 37 006 0296 25
Han HoodsHousings
Hoods/Housings Han® M with metric thread Size 6 B
for harsh environmental requirements
Stock items in bold type
Hoodside-entry
Hoodstop-entry
Protection covermetal
Housingbulkhead mounting
Housingsurface mounting 2 side-entries
Hou
sing
sH
oods
Panel cut out
with metalcover
with thermo-plastic cover
Part No.
Identification Low construction High construction M Drawing Dimensions in mm
31.28
10 19 37 010 0465 2 x 20
10 19 37 010 0447 32
10 19 37 010 0291 25
Han HoodsHousings
Hoods/Housings Han® M with metric thread Size B
Identification Size Part No. Pg Drawing Dimensions in mm
Hoodsfor special applications
top-entry
Hoodstop-entry
Stock items in bold type
31.29
16 19 37 016 0587 32
24 19 37 024 0587 32
16 19 37 016 0487 32
24 19 37 024 0487 32
24 09 37 024 0381
16 19 37 016 0282 2 x 32
24 19 37 024 0282 2 x 32
16 105 117 81
24 132 144 81
24 130 140 108 x 35
Han HoodsHousings
Hoodsside-entry
Hoodstop-entry
Housingsbulkhead mounting
Housingssurface mounting
16 93.5 76
24 120.0 87
Size a b h
Size a b
16 93.5 76
24 120.0 87
Size a b
Size a b Panel cut out
Hoods/Housings Han® M with metric thread Size B
with central locking lever
Identification Size Part No. M Drawing Dimensions in mm
Hou
sing
sH
oods
Stock items in bold type
31.30
h a
h a
a
a b c
h a b c d
a
24 19 37 024 0733 40
Han HoodsHousings
Hoods/Housings Han® M with metric thread Size B
for harsh environmental requirements
Part No.Identification Size low construction high construction M Drawing Dimensions in mm
Stock items in bold type
10 09 37 010 0301 – 83 93 60
16 09 37 016 0301 – 103 113 82
24 09 37 024 0301 – 130 140 108
10 19 37 010 1270 2 x 20 54 82 94 40 5210 19 37 010 0272 2 x 32 81 82 94 45 57
16 19 37 016 1231 1 x 25 56 105 117 45 5716 19 37 016 0272 2 x 32 81 105 117 45 57
24 19 37 024 0272 2 x 32 81 132 144 45 57
10 19 37 010 1520 20 52.0 73.510 19 37 010 0526 25 72.0 73.0
16 19 37 016 1521 25 62.5 93.516 19 37 016 0527 32 76.0 93.516 19 37 016 0528 40 76.0 97.5
24 19 37 024 1521 25 60.0 120.524 19 37 024 0527 32 76.0 120.524 19 37 024 0528 40 76.0 120.0
Hoodsside-entry
Hoo
ds
Protection coversmetal
10 19 37 010 1420 20 45 73.010 19 37 010 0427 32 72 73.0
16 19 37 016 1421 25 45 93.516 19 37 016 0427 32 76 93.5
24 19 37 024 1421 25 55 120.024 19 37 024 0427 32 76 120.024 19 37 024 0428 40 76 120.0
Hoodstop-entry
10 09 37 010 5403 – 79.0
16 09 37 016 5402 – 99.5
24 09 37 024 5402 – 126.0
Housingsbulkhead mounting
Hou
sing
s
Panel cutout
Housingssurface mounting
10 09 37 010 5405 – 79.5
16 09 37 016 5405 – 99.5
24 09 37 024 5405 – 126.5
Protection coversmetal
Hoodcable to cablemetal
31.31
19 37 048 0548 40
09 37 048 0301 –
19 37 048 0448 4019 37 048 0449 50
19 37 048 0401 4 x 25
Han HoodsHousings
Hoods/Housings Han® M with metric thread Size 48 B
with 1 lever on the housing for 2 inserts
Identification Part No. M Drawing Dimensions in mm
Hoodsside-entry
with thermo-plastic cover
Housingsbulkhead mounting
Hou
sing
sH
oods
Hoodstop-entry
Hoodstop-entry
Panel cut out
Stock items in bold type
3 A 19 40 003 0400 19 40 003 0410 20
3 A 09 40 003 0301 09 40 003 0311
3 A 19 40 003 0950 20
3 A 09 40 003 0950 –
3 A 09 40 003 0902 –
3 A 19 40 003 0900 20
31.32
Han HoodsHousings
Han® 3 HPR with metric thread Size 3 A
Part No.Identification Size Screw locking M Drawing Dimensions in mm
Accessories Size Part No. M Drawing Dimensions in mm
Hoodtop-entrywith sealing screw*
Housingbulkhead mountingwith sealing screw*
Housingsbulkhead and surfa-ce mountingwith sealing screw*
Adaptorfor assembly in angledposition
Stock items in bold type* Sealing on the insert has to be removed
Seal screw
Seal screw
Panel cut out 21.3 x 21.3 mm
closed
open
Seal screw
31.33
6 19 40 006 0510 20
6 19 40 006 0501 19 40 006 0511 256 19 40 006 0512 32
10 19 40 010 0501 19 40 010 0511 2510 19 40 010 0512 32
16 19 40 016 0502 19 40 016 0512 3216 19 40 016 0513 4016 19 40 016 0514 50
24 19 40 024 0512 3224 19 40 024 0503 19 40 024 0513 4024 19 40 024 0514 5024 19 40 024 0537 2 x 32
6 19 40 006 0410 206 19 40 006 0401 19 40 006 0411 256 19 40 006 0412 326 19 40 006 0413 40
10 19 40 010 0401 19 40 010 0411 2510 19 40 010 0412 3210 19 40 010 0430 2 x 20
16 19 40 016 0411 2516 19 40 016 0402 19 40 016 0412 3216 19 40 016 0413 4016 19 40 016 0414 5016 19 40 016 0431 2 x 25
24 19 40 024 0402 19 40 024 0412 3224 19 40 024 0413 4024 19 40 024 0414 5024 19 40 024 0432 2 x 3224 19 40 024 0433 2 x 4024 19 40 024 0461 3 x 25
24 19 40 024 0420 63
24 19 40 024 0419 5024 19 40 024 0467 3 x 32
6 B 133 101
10 B 146 101
16 B 166 111
24 B 193 111
6 B 133 101
10 B 146 101
16 B 166 111
24 B 193 111
Han HoodsHousings
Hoods/Housings Han® HPR Size B
Part No.
Identification Size Screw locking M Drawing Dimensions in mm
Hoodsside-entry
Hoodstop-entry
Hoodtop-entry
Stock items in bold type
Size a h
Size a h
31.34
6 09 40 006 0301 09 40 006 0311
10 09 40 010 0301 09 40 010 0311
16 09 40 016 0301 09 40 016 0311
24 09 40 024 0301 09 40 024 0311
6 09 40 006 5401 09 40 006 5411
10 09 40 010 5401 09 40 010 5411
16 09 40 016 5401 09 40 016 5411
24 09 40 024 5401 09 40 024 5411
6 09 40 000 9901
10 09 40 000 9902
16 09 40 000 9903
24 09 40 000 9904
6 B 70 133 48
10 B 83 146 60
16 B 103 166 82
24 B 130 193 108
6 B 70 96
10 B 83 109
16 B 103 129
24 B 130 156
6 B 133
10 B 146
16 B 166
24 B 193
6 19 40 006 1260 1 x 206 19 40 006 1261 1 x 256 19 40 006 1262 1 x 32
10 19 40 010 1260 1 x 2010 19 40 010 1262 1 x 32
16 09 40 016 1201 –16 19 40 016 1262 1 x 3216 19 40 016 1263 1 x 4016 19 40 016 1273 2 x 40
24 19 40 024 1263 1 x 4024 19 40 024 1273 2 x 40
6 B 127 156
10 B 140 169
16 B 160 189
24 B 187 216
Han HoodsHousings
Hoods/Housings Han® HPR with metric thread Size B
Part No.
Identification Size Toggle locking Screw locking M Drawing Dimensions in mm
Housingsbulkhead mounting
Stock items in bold type
Protection covers
Mounting frames
Size a b c
Size a b
Housingssurface mounting
Size a b
Size a
31.35
19 62 003 1640 20
19 62 003 1440 20
09 62 003 0801
09 62 003 0301
19 62 003 1250 20
19 62 003 1750 20
Han HoodsHousings
Stock items in bold type
Hoods/Housings Han® EMC with metric thread Size 3 A
Identification Part No. M Drawing Dimensions in mm
Hoo
ds
Hoodside-entry
Hoodtop-entry
Hou
sing
s
Housingsbulkhead mounting
Panel cut out 22 x 22 mm
Housingsurface mounting
1 side-entry
Panel cut out 22 x 22 mm
Hoodcable to cable
1 side-entry
31.36
Han HoodsHousings
Hoods/Housings Han® EMC with metric thread Size 10 A, 16 A
Identification Size Part No. Pg Drawing Dimensions in mm
Hoodsside-entry
10 A 19 62 015 0546 25
16 A 19 62 025 0546 25
Hoodstop-entry
10 A 19 62 015 0446 25
16 A 19 62 025 0446 25
Housingsbulkhead mounting
10 A 09 62 015 0301
16 A 09 62 025 0301
Size a h
10 A 64 70
16 A 80 70
Size a h
10 A 64 70
16 A 80 70
Size a b Panel cut out
10 A 81 70 24 x 57
16 A 96 86 24 x 73
Stock items in bold type
Hoo
dsH
ousi
ngs
31.37
6 19 62 006 0541 25
10 19 62 010 0542 32
16 19 62 040 0542 32
24 19 62 064 0543 40
6 19 62 006 0441 256 19 62 006 0442 32
10 19 62 010 0442 32
16 19 62 040 0442 32
24 19 62 064 0443 40
6 09 62 006 0301
10 09 62 010 0301
16 09 62 040 0301
24 09 62 064 0301
Han HoodsHousings
Hoods/Housings Han® EMC with metric thread Size B
Identification Size Part No. M Drawing Dimensions in mm
Hoodsside-entry
Hoodstop-entry
Housings bulkhead mounting
Hou
sing
sH
oods
Size a b h
6 72 – 75
10 85 76 75
16 106 86 75
24 132 100 85
Size a h
6 72 75
10 85 75
16 106 75
24 132 85
Stock items in bold type
Size a b Panel cut out6 80 70 48 x 35
10 93 83 60 x 3516 113 103 82 x 3524 140 130 108 x 35
31.38
10 19 62 810 1520 2010 19 62 810 0526 2510 19 62 810 0527 32
16 19 62 816 1521 2516 19 62 816 0527 32
24 19 62 824 1521 2524 19 62 824 0527 3224 19 62 824 0528 40
6 19 62 806 1540 206 19 62 806 0546 256 19 62 806 0547 32
10 19 62 810 0547 32
06 09 62 806 0301 –
10 09 62 810 0301 –
16 09 62 816 0301 –
24 09 62 824 0301 –
10 19 62 810 0757 32
10 19 62 810 1420 2010 19 62 810 1421 2510 19 62 810 0426 2510 19 62 810 0427 32
16 19 62 816 1421 2516 19 62 816 0427 32
24 19 62 824 1422 19 62 824 0427 32
6 19 62 806 1440 206 19 62 806 0446 256 19 62 806 0447 32
10 19 62 810 0446 2510 19 62 810 0447 32
6 B 70 80 48 x 3510 B 83 93 60 x 3516 B 103 113 82 x 3524 B 130 140 108 x 35
6 19 62 806 1290 2 x 20
10 19 62 810 1271 2 x 2510 19 62 810 0272 2 x 32
16 19 62 816 1271 2 x 2516 19 62 816 0273 2 x 40
24 19 62 824 1271 2 x 2524 19 62 824 0273 2 x 40
6 B 70 8210 B 82 9416 B 105 11724 B 132 144
Hoods/Housings Han® EMC with metric thread Size B
with 2 levers on the housing
Part No.
Identification Size Low construction High construction M Drawing Dimensions in mm
with double lever
Hoodsside-entry
with singlelever
Hoodstop-entry
with singlelever
Hoodscable to cable
with double lever
Low HighSize a construction h construction h
6 B 60.0 43.0 7210 B 73.0 57.0 7216 B 93.5 62.5 7624 B 120.5 62.5 76
Low HighSize a construction h construction h
6 B 60.0 40 7210 B 73.0 45 7216 B 93.5 55 7624 B 120.5 55 76
Han HoodsHousings
Stock items in bold type
Housingsbulkhead mountingwith 2 locking leversand 1 adapter frame
Size 6 Bwith 1 locking lever only
Housingssurface mounting
Size a b Panel cut out
Size a b
31.39
*
*
*
*
Han HoodsHousings
Hoods/Housings with metric thread Size B
for special applications
Identification Size Part No. Pg Drawing Dimensions in mm
Hoodstop-entry
10 19 30 010 0465 2 x 20
16 19 30 016 0466 2 x 25
24 19 30 024 0467 2 x 32
Hoodsside-entry
16 19 30 016 0666 2 x 25
24 19 30 024 0666 2 x 25
Hoodswithout entryfor customized drillings
double lever 6 09 30 006 0801 –
10 09 30 010 0801 –
16 09 30 016 0801 –
24 09 30 024 0801 –
single lever 10 09 30 010 0803 –
16 09 30 016 0803 –
24 09 30 024 0803 –
Flange housing6 19 30 006 0716 1 x 25
10 73,0 72 20 2 x 20
16 93.5 76 36 2 x 32
24 120,0 76 52 2 x 25
Size a h x M
Size a x M
16 93.5 36 2 x 25
24 120.0 56 2 x 25
Size a h
10 73.0 72
16 93.5 76
24 120.0 76
Stock items in bold type
* 10 B:housingwidth 43 mm
* 10 B:housing width 43 mm
* 10 B:housing width 43 mm
Han® Standard Hood
Technical Details Features
Identification Part-Number M Drawing Dimensionsinmm
Material Die cast aluminiumSurface Powder coated RAL 7037Locking element V2A SteelSeal NBRLimiting temperatures -40°C . . . +125°CDegree of protection accd . to DIN EN 60 529 for coupled connector IP 65
• Extended height• Big wiring space• Optimised 30° angle for cable entry• Compatible with standard housings
Hood top entry with 2 levers on the housing
Hood side entry with 2 levers on the housing
Hood side entry with 1 central lever
19 30 024 0429
19 30 024 0529
19 30 024 0589
50
50
50
M50, Size 24 B
�
11 30 016 0520
11 30 024 0520
11 30 000 9954
11 30 000 9955
11 30 000 9956
11 30 000 9957
11 30 000 9958
11 30 000 9959
Han® Easy-Hood
16 B
24 B
_
_
_
_
_
_
Identification Partnumber Size Drawing Dimensionsinmm
Advantages Technical characteristics• Optimised handling for big wires or multiple cables• Reduced wiring times• Visible wiring• Integrated cable gland• Cord grip• Captive screws• Optimised cable entry
Material Aluminium die-castSurface powder-coated RAL 7037 (grey)Seal NBRLimiting temperatures -40 / +85°CDegree of protection accd . to DIN 60 529 IP 65
Packagingcontentupper hood, lower hood, 3fixingscrews,cordgrip, 2screwsforclampfixing, 2 adaptors for guide pins and bushes
Han® Easy-Hood
Han® Easy-Hood side entry
Cable seal 17 - 19 mm
Cable seal 20 - 22 mm
Cable seal 23 - 25 mm
Cable seal 26 - 28 mm
Cable seal 29 - 31 mm
Cable seal 32 - 34 mm
Size B
Size a b c
16 B 100 mm 94 mm 112 mm
24 B 108 mm 120 .5 mm 139 mm
�
Han® Easy-Hood
0,8 Nm
AB
The Han® Easy-Hood offers a vertical split into two shells with new assembling possibilities . Assembly processes can be changed to much more modular production steps with new logistics . The wiring can be controlled . All manual movements changed from axial to vertical processes leading to automation possibilities .
Technical Description
Size B
Notewhenusingguidepins/bushes:When using guide pins / bushes the user needs to apply the adaptors „A“ on both sides of the insert „B“ . The recommended tightening torque is 0 .8 Nm . Afterwards the insert can be placed in the Han® Easy-Hood .
2 Nm
2 Nm
�