FIBER-OPTIC SOLUTIONSOptical fibers are fitted in front of the emitter and receiver (the basic operation is identical for both glass and synthetic optical fibers). These fibers work as the extended “eye” of the photo sensor. As optical fiber conductors are very small and flexible, they provide a truly practical solution to the problem of sensing in highly inaccessible places. Furthermore, they do not carry any electrical potential, and sensing operations are therefore possible without special safety measures, even in areas where there is an explosion risk, or in the presence of strong electrical and magnetic fields (high-voltage equipment, electrical welding equipment). Even the tiniest objects can be detected by using appropriately thin fibers. Optical fibers can act as both through-beam (Fig. 1) and diffuse sensors (Fig. 2).

FIBER-OPTIC AMPLIFIERS

SERIES 3030 / 3031They combine high performance (series 3030), good performance and moderate cost (series 3031) with reduced dimensions (30 x 30 x 15 mm housing). They are intended for general use, particularly where small size is required. Despite their size, they feature all the usual protection functions, are robust and can be used for demanding industrial applications.

SERIES 3060 / 3065 / 3066These fiber-optic amplifiers for DIN-rail mounting (DIN/EN 50022) feature large sensing ranges, out-standing detection properties for both long and very short operating distances, high temperature stability and durability, thanks to stabilized light power (teach-in models only), and high switching frequency. For the teach-in versions, built-in adjustable pulse delay and stretching are standard. The exceptionally small housing (30 x 60 x 10 mm) allows for optimum stacking of even a large number of switches. In addition, the devices are optimized for simple and easily understandable operation. Presently, the series offers distance setting by means of potentiometer and teach-in; the latter with additional manual fine adjustment. According to choice, Teach 1 (only on background), Teach 2 (first on target, then on background), or Dynamic Teach may be used. The teach process can also be launched from a distance via a separate input.

Fig. 1 Fig. 2

INTRODUCTION

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 3: CONTRINEX Fiber Optic Solutions

SyNThETIC OPTICAL FIBERSThis catalog includes a comprehensive range of synthetic optical fibers for the detection of smallest objects, and for use in highly inaccessible places. The fibers can be cut on site to the length required for a specific application.

APPLICATION-SPECIFIC FIBERS− Cylindrical light beam− Background suppression− Multi-beam− Liquid level monitoring− Low and high temperatures

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 4: CONTRINEX Fiber Optic Solutions

MAIN FEATURES− Small, but robust− Glass window, therefore scratch resistant and easy to clean− Excellent resistance to environmental influences thanks to polyurethane potting of the electronic

module− High degree of protection: IP 67 (series 3030) / IP 65 (series 3031)− Convenient sensitivity adjustment by means of the built-in 12-turn potentiometer

PROTECTIONThe switches are protected against overloads, short-circuits and all possible wire reversals. Fur-thermore, protection against overvoltages caused by inductive loads on the output and against voltage spikes on the power supply lines are built in. Appropriate technology prevents malfunctions or destruction caused by electrostatic discharges, fast transients, or HF fields. Thanks to optimum sealing, the devices are resistant to environmental influences (IP 67 for series 3030 devices / IP 65 for series 3031 devices).

LEDSFor reliable operation the green LED (excess-gain indication) must light up. The yellow LED indicates the output state.

CONNECTIONSwitches with 3 m PVC cable 4 x 0.14 mm2 or 4-pole S8 connector (series 3030) and 2 m PVC cable 3 x 0.14 mm2 or 3-pole S8 connector (series 3031) are standard. Other cable types or lengths are available on request.

DOCUMENTATIONDetailed data sheets for these products can be found on the Contrinex website www.contrinex.com or ordered free of charge from our distributors.

Technical drawings can be downloaded as files from the Contrinex website and directly imported into your construction drawings.

30x30x15mm Glass-fiberrein­forcedPBTP/poly­buty­len­e-

tereph­th­alate(Crastin­) 10...36VDC 20% 200mAmax. 2.0Vmax.at200mA 1,000Hz 0.5msec

5,000Lux 10,000Lux -25...+55°C(-13...+131°F) IP67(3030)/IP65(3031)

1kV Level2(3030)/3(3031) Level3 Level3

Housin­gsize Housin­gmaterial

Supply­voltageran­geUB

Max.ripplecon­ten­t Outputcurren­t Outputvoltagedrop Max.switch­in­gfrequen­cy­ Switch­in­gtime(↑an­d↓) Max.ambien­tligh­t: h­alogen­ sun­ Ambien­ttemperatureran­ge Degreeofprotection­ EMCprotection­: IEC60947-5-2 IEC61000-4-2 IEC61000-4-3 IEC61000-4-4

TEChNICAL DATA

FIBER-OPTIC AMPLIFIERSwITh POTENTIOMETER

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 5: CONTRINEX Fiber Optic Solutions

20

M4 4,5 21 4,5

8 22

30

4,5

4,5

21

15

30

822

14

7

[mm]

60

50

40

30

20

10

01020 10 20[mm]

s

a

a

s20

M4 4,5 21 4,5

8 22

30

4,5

4,5

21

15

30

822

14

7

[mm]

120

100

80

60

40

20

02040 20 40[mm]

s

a

a

s

PART REFERENCESPartref.:(bold:preferredty­pes)NPNch­an­geover/cableNPNligh­t-ON+excessgain­/cableNPNch­an­geover/con­n­.S84-poleNPNligh­t-ON+excessgain­/S84-p.PNPch­an­geover/cablePNPligh­t-ON+excessgain­/cablePNPch­an­geover/con­n­.S84-polePNPligh­t-ON+excessgain­/S84-p.Wirin­g(page23)

Partref.:(bold:preferredty­pes)NPNligh­t-ON/cableNPNdark-ON/cableNPNligh­t-ON/con­n­ectorS83-poleNPNdark-ON/con­n­ectorS83-polePNPligh­t-ON/cablePNPdark-ON/cablePNPligh­t-ON/con­n­ectorS83-polePNPdark-ON/con­n­ectorS83-poleWirin­g(page23)

LFK-3030-101LFK-3030-102LFS-3030-101LFS-3030-102LFK-3030-103LFK-3030-104LFS-3030-103LFS-3030-104

Diagram2

LFK-3031-301LFK-3031-302LFS-3031-301LFS-3031-302LFK-3031-303LFK-3031-304LFS-3031-303LFS-3031-304

Diagram1

Operatin­gdistan­ce Stan­dardtarget No-loadsupply­curren­t Emitter Weigh­t(cable/con­n­ectormodel)

TyPE SPECIFIC DATA 60mm(with­LFP-1002-020) 100x100mmwh­ite 15mA(ty­pical) LEDred660n­m 78g/18g

STANDARD 120mm(with­LFP-1002-020) 100x100mmwh­ite 20mA(ty­pical) LEDred660n­m 78g/17g

hIgh PERFORMANCE TyPE SPECIFIC DATA Operatin­gdistan­ce Stan­dardtarget No-loadsupply­curren­t Emitter Weigh­t(cable/con­n­ectormodel)

Response curve:

SERIES 3031/3030 60 mm 120 mm

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 6: CONTRINEX Fiber Optic Solutions

MAIN FEATURES− Fiber-optic amplifiers for DIN-rail mounting (DIN/EN 50022)− Ideal for stacking, thanks to 10 mm housing width− Large sensing range of 0 ... 200 mm (red light) / 0 ... 100 mm (blue light) / 0 ... 140 mm (high

switching frequency)− No blind zone− Distance setting by means of 12-turn potentiometer with illuminated scale− Large setting range of 20 ... 200 mm (red light) / 20 ... 100 mm (blue light) / 20 ... 140 mm (high

switching frequency)− Switch selectable light-ON / dark-ON output, as well as excess-gain output− Fibers (∅ 2.2 mm) connected by quick-locking− Operating and display elements protected by transparent cover

PROTECTIONThe switches are protected against overloads, short-circuits and all possible wire reversals. Fur-thermore, protection against overvoltages caused by inductive loads on the output and against voltage spikes on the power supply lines are built in. Appropriate technology prevents malfunctions or destruction caused by electrostatic discharges, fast transients, or HF fields. Thanks to optimum sealing, the devices are resistant to environmental influences (IP 64).

LEDSFor reliable operation the green LED (excess-gain indication) must light up. The yellow LED indicates the output state.

CONNECTIONDevices with 2 m PVC cable 4 x 0.25 mm2 or 4-pole S8 connector are standard. Other cable types or lengths are available on request.

DOCUMENTATIONDetailed data sheets for these products can be found on the Contrinex website www.contrinex.com or ordered free of charge from our distributors.

Technical drawings can be downloaded as files from the Contrinex website and directly imported into your construction drawings.

TEChNICAL DATA

31x60x10mm Glass-fiberrein­forcedPBTP/poly­buty­len­e-

tereph­th­alate(Crastin­) 10...30VDC 20% 200mAmax. 2.0Vmax.at200mA 1,500Hz/5,000Hz(h­igh­frequen­cy­) 330µsec/100µsec(h­igh­frequen­cy­)

5,000Lux 10,000Lux -25...+55°C(-13...+131°F) IP64

5kV Level2 Level3 Level2

Housin­gsize Housin­gmaterial

Supply­voltageran­geUB

Max.ripplecon­ten­t Outputcurren­t Outputvoltagedrop Max.switch­in­gfrequen­cy­ Switch­in­gtime(↑an­d↓) Max.ambien­tligh­t: h­alogen­ sun­ Ambien­ttemperatureran­ge Degreeofprotection­ EMCprotection­: IEC60947-5-2 IEC61000-4-2 IEC61000-4-3 IEC61000-4-4

FIBER-OPTIC AMPLIFIERSwITh POTENTIOMETER

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 7: CONTRINEX Fiber Optic Solutions

60 40 20 0 40 60[mm]

50

100

150

200

20

[mm]s

a

a

s

60 40 20 0 40 60[mm]

50

100

150

200

20

[mm] s

a

a

s

PART REFERENCES

LFK-3260-101

LFS-3260-101

LFK-3260-103

LFS-3260-103

Diagram2

Partref.:(bold:preferredty­pes)NPNpoten­tiometer/cableNPNpoten­tiometer/con­n­.S84-polePNPpoten­tiometer/cablePNPpoten­tiometer/con­n­.S84-poleWirin­g(page23)

LFK-3360-101

LFS-3360-101

LFK-3360-103

LFS-3360-103

Diagram2

LFK-3060-101

LFS-3060-101

LFK-3060-103

LFS-3060-103

Diagram2

Response curve:

TyPE SPECIFIC DATA STANDARD BLUE LIghT hIgh FREqUENCy Operatin­gdistan­ce Stan­dardtarget No-loadsupply­curren­t(atUB=24V) Emitter Weigh­t(cable/con­n­ectormodel)

200mm(with­LFP-1002-020) 100x100mmwh­ite 15mA(ty­pical) LEDred680n­m 69g/18g

140mm(with­LFP-1002-020) 100x100mmwh­ite 15mA(ty­pical) LEDred680n­m 69g/18g

100mm(with­LFP-1002-020) 100x100mmwh­ite 15mA(ty­pical) LEDblue465n­m 69g/18g

200 mm 140 mm 100 mmSERIES 3060

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 8: CONTRINEX Fiber Optic Solutions

MAIN FEATURES− Fiber-optic amplifiers for DIN-rail mounting (DIN/EN 50022)− Ideal for stacking, thanks to 10 mm housing width− Excellent detection properties across a wide sensing range of 0...200 mm (red light) / 0...100 mm

(blue light) / 0...140 mm (high switching frequency)− No blind zone− Distance setting by means of teach-in with additional manual fine adjustment− Large setting range of 20 ... 200 mm (red light) / 20 ... 100 mm (blue light) / 20 ... 140 mm (high

switching frequency)− Regulated emitter light power− Adjustable output switching delay and stretching− Light-ON / dark-ON selectable− Signal-strength and excess-gain indication by means of a bargraph− Fibers (∅ 2.2 mm) connected by quick-locking− Operating and display elements protected by transparent cover

PROTECTIONThe switches are protected against overloads, short-circuits and all possible wire reversals. Fur-thermore, protection against overvoltages caused by inductive loads on the output and against voltage spikes on the power supply lines are built in. Appropriate technology prevents malfunctions or destruction caused by electrostatic discharges, fast transients, or HF fields. Thanks to optimum sealing, the devices are resistant to environmental influences (IP 64).

LEDSA yellow LED indicates the switching state. Signal-strength and excess-gain indication by means of a bargraph allow for optimum alignment of the optical fibers. The status LED shows the output state of the device during the teach process, and 8 green LEDs indicate the activated functions.

CONNECTIONDevices with 2 m PVC cable 4 x 0.25 mm2 or 4-pole S8 connector are standard. Other cable types or lengths are available on request.

DOCUMENTATIONDetailed data sheets for these products can be found on the Contrinex website www.contrinex.com or ordered free of charge from our distributors.

Technical drawings can be downloaded as files from the Contrinex website and directly imported into your construction drawings.

TEChNICAL DATA 31x60x10mm Glass-fiberrein­forcedPBTP/poly­buty­len­e-

tereph­th­alate(Crastin­) 10...30VDC 20% 200mAmax. 2.0Vmax.at200mA 1,500Hz/5,000Hz(h­igh­frequen­cy­) 330µsec/100µsec(h­igh­frequen­cy­)

5,000Lux 10,000Lux -25...+55°C(-13...+131°F) IP64

5kV Level2 Level3 Level2

Housin­gsize Housin­gmaterial

Supply­voltageran­geUB

Max.ripplecon­ten­t Outputcurren­t Outputvoltagedrop Max.switch­in­gfrequen­cy­ Switch­in­gtime(↑an­d↓) Max.ambien­tligh­t: h­alogen­ sun­ Ambien­ttemperatureran­ge Degreeofprotection­ EMCprotection­: IEC60947-5-2 IEC61000-4-2 IEC61000-4-3 IEC61000-4-4

FIBER-OPTIC AMPLIFIERSwITh TEACh-IN

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 9: CONTRINEX Fiber Optic Solutions

60 40 20 0 40 60[mm]

50

100

150

200

20

[mm]s

a

a

s

60 40 20 0 40 60[mm]

50

100

150

200

20

[mm] s

a

a

s

Response curve:

PART REFERENCES

LFK-3265-101

LFS-3265-101

LFK-3265-103

LFS-3265-103

Diagram4

Partref.:(bold:preferredty­pes)NPNteach­-in­/cableNPNteach­-in­/con­n­ectorS84-polePNPteach­-in­/cablePNPteach­-in­/con­n­ectorS84-poleWirin­g(page23)

LFK-3365-101

LFS-3365-101

LFK-3365-103

LFS-3365-103

Diagram3

LFK-3065-101

LFS-3065-101

LFK-3065-103

LFS-3065-103

Diagram3

TyPE SPECIFIC DATA STANDARD BLUE LIghT hIgh FREqUENCy Operatin­gdistan­ce Stan­dardtarget No-loadsupply­curren­t(atUB=24V) Emitter Weigh­t(cable/con­n­ectormodel)

200mm(with­LFP-1002-020) 100x100mmwh­ite 25mA(ty­pical) LEDred680n­m 68g/17g

100mm(with­LFP-1002-020) 100x100mmwh­ite 25mA(ty­pical) LEDblue465n­m 68g/17g

140mm(with­LFP-1002-020) 100x100mmwh­ite 25mA(ty­pical) LEDred680n­m 68g/17g

200 mm 140 mm 100 mmSERIES 3065

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 10: CONTRINEX Fiber Optic Solutions

MAIN FEATURES− Fiber-optic amplifiers for DIN-rail mounting (DIN/EN 50022)− Ideal for stacking, thanks to 10 mm housing width− Setting range of 20 ... 200 mm− Distance setting by means of teach-in with additional manual fine adjustment− Teach 1 (background), Teach 2 (target and background), or Dynamic Teach− Signal-strength and treshold indication by means of a LC display− Adjustable output switching delay and stretching− High switching frequency up to 4 kHz− Light-ON / dark-ON selectable− IO-link (PNP version)− Fibers (∅ 2.2 mm) connected by quick-locking− Operating and display elements protected by transparent cover

PROTECTIONThe switches are protected against overloads, short-circuits and all possible wire reversals. Fur-thermore, protection against overvoltages caused by inductive loads on the output and against voltage spikes on the power supply lines are built in. Appropriate technology prevents malfunctions or destruction caused by electrostatic discharges, fast transients, or HF fields. Thanks to optimum sealing, the devices are resistant to environmental influences (IP 64).

LED / LC DISPLAyA yellow LED indicates the switching state. The 8-digit, 14 segment digital LCD indicates the signal strength as well as the switching threshold.

CONNECTIONDevices with 2 m PVC cable 4 x 0.25 mm2 or 4-pole S8 connector are standard. Other cable types or lengths are available on request.

DOCUMENTATIONDetailed data sheets for these products can be found on the Contrinex website www.contrinex.com or ordered free of charge from our distributors.

Technical drawings can be downloaded as files from the Contrinex website and directly imported into your construction drawings.

TEChNICAL DATA Housin­gsize Housin­gmaterial

Supply­voltageran­geUB

Max.ripplecon­ten­t Outputcurren­t Outputvoltagedrop Max.switch­in­gfrequen­cy­ Switch­in­gtime(↑an­d↓) Max.ambien­tligh­t: h­alogen­ sun­ Ambien­ttemperatureran­ge Degreeofprotection­ EMCprotection­: IEC60947-5-2 IEC61000-4-2 IEC61000-4-3 IEC61000-4-4 IEC61000-4-6

31x60x10mm Glass-fiberrein­forcedPBTP/poly­buty­len­e-

tereph­th­alate(Crastin­) 10...30VDC 20% 200mAmax. 2.0Vmax.at200mA 4,000Hz ≥80µsec

5,000Lux 10,000Lux -5...+55°C(+23...+131°F) IP64

5kV Level2 Level3 Level2 Level2

FIBER-OPTIC AMPLIFIERSwITh DIgITAL DISPLAy

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 11: CONTRINEX Fiber Optic Solutions

Display value as a function of the distance Response curve:

PART REFERENCESPartref.:(bold:preferredty­pes)

NPNteach­-in­/cableNPNteach­-in­/con­n­ectorS84-polePNPteach­-in­&IO-lin­k/cablePNPteach­-in­&IO-lin­k/S84-poleWirin­g(page23)

LFK-3066-101

LFS-3066-101

LFK-3066-403

LFS-3066-403

Diagram3

TyPE SPECIFIC DATA DIgITAL DISPLAy Operatin­gdistan­ce Stan­dardtarget No-loadsupply­curren­t(atUB=24V) Emitter Weigh­t(cable/con­n­ectormodel)

200mm(with­LFP-1002-020) 100x100mmwh­ite 30mA(ty­pical) LEDred680n­m 68g/17g

SERIES 3066 200 mm

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 12: CONTRINEX Fiber Optic Solutions

MAIN FEATURES− Very small dimensions− Long operating distances− Low bending radii− Can be cut on site− Wide range of types− High degree of protection of the sensing head

DOCUMENTATIONDetailed data sheets for these products can be found on the Contrinex website www.contrinex.com or ordered free of charge from our distributors.Technical drawings can be downloaded as files from the Contrinex website and directly imported into your construction drawings.

*LFP-1002-020-002/LFP-2002-020-002**LFP-1108/1109/1011-020

TEChNICAL DATA Ambien­ttemperatureran­ge Protection­degreeofsen­sin­gh­ead Stan­dardlen­gth­ Fiberben­din­gradii: min­iature/multi-beam stan­dard/coaxial/h­igh­temperature liquidlevelmon­itorin­g flexible/backgroun­dsuppression­ lumin­ous Ben­din­gradiusofligh­t-outlettube Ten­sileload Fibermaterial Sleevematerial Sen­sin­gh­eadmaterial Sen­sin­gh­eadligh­t-outlettubematerial Opticalatten­uation­: stan­dard/lumin­ous min­iature flexible coaxial multi-beam An­gleofin­ciden­ce Tigh­ten­in­gtorque: M3 M4 M5 M6 M8

-25...+70°C(-13...+158°F)/-55...+105°C(-67...+221°F)* IP67(IP68forLFP-1010-020) 2m±0.1m(oth­erlen­gth­son­request)

15mm 25mm 25mm 2mm 40mm 25mm 30Nmax. PMMA Poly­eth­y­len­e Stain­lesssteelV2A/PBTP** Stain­lesssteelV2A

0.2dB/mmax.at660n­m 0.22dB/mmax.at660n­m 0.4dB/mmax.at660n­m 0.42dB/mmax.at660n­m 0.65dB/mmax.at660n­m Seedatash­eets

1Nm 2Nm 3Nm 4Nm 10Nm

Doublefiber(10m) Nosensinghead Partreference LFP-0005-100 Operatin­gdistan­ce with­series3030 120mm(2mfiber,diffusesen­sin­g) with­series3031 60mm(2mfiber,diffusesen­sin­g) with­series3060/65/66 200mm(2mfiber,diffusesen­sin­g) Outsidefiber separabledoublefiber,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics Lon­goperatin­gdistan­ce

Individualfiber(10m) Nosensinghead Partreference LFP-0004-100 Operatin­gdistan­ce with­series3030 400mm(2mfiber,th­rough­-beamsen­sin­g) with­series3031 200mm(2mfiber,th­rough­-beamsen­sin­g) with­series3060/65/66 700mm(2mfiber,th­rough­-beamsen­sin­g) Outsidefiber in­dividualfiber,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics Lon­goperatin­gdistan­ce

SyNThETIC OPTICAL FIBERS

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 13: CONTRINEX Fiber Optic Solutions

Housingsize:M� Miniature Partreference LFP-1001-020 Operatin­gdistan­ce with­series3030 40mm with­series3031 20mm with­series3060/65/66 70mm

Outsidefiber 1separabledoublefiber,∅1mm In­n­erfiber ∅0.5mm Specialch­aracteristics High­estresolution­

Part reference (bold: preferred types)

Housingsize:∅2.3 mm Miniature Partreference LFP-1012-020 Operatin­gdistan­ce with­series3030 40mm with­series3031 20mm with­series3060/65/66 70mm Outsidefiber 1separabledoublefiber,∅1mm In­n­erfiber ∅0.5mm Specialch­aracteristics High­estresolution­

Housingsize:M� Miniature Partreference LFP-1004-020 Operatin­gdistan­ce with­series3030 40mm with­series3031 20mm

with­series3060/65/66 70mmOutsidefiber 1separabledoublefiber,∅1mm

In­n­erfiber ∅0.5mm Specialch­aracteristics Sen­sin­gh­eadwith­ben­dableligh­t-outlettubeforeaseofposition­in­g High­estresolution­

Housingsize:M� Standard Partreference LFP-1002-020 Operatin­gdistan­ce with­series3030 120mm with­series3031 60mm with­series3060/65/66 200mm Outsidefiber 1separabledoublefiber,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics Lon­goperatin­gdistan­ce

Housingsize:M� Flexible Partreference LFP-1102-020 Operatin­gdistan­ce with­series3030 90mm with­series3031 45mm with­series3060/65/66 150mm Outsidefiber 1separabledoublefiber,∅2.2mm In­n­erfiber 151x∅75µm Specialch­aracteristics Very­smallben­din­gradius

SyNThETIC OPTICAL FIBERSDIFFUSE SENSORS

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 14: CONTRINEX Fiber Optic Solutions

Housingsize:M� Luminous Partreference LFP-1202-020 Operatin­gdistan­ce with­series3030 160mm with­series3031 80mm with­series3060/65/66 260mm Outsidefiber 1separabledoublefiber,∅2.2mm In­n­erfiber ∅1.5mm Specialch­aracteristics Lon­gestoperatin­gdistan­ce

Housingsize:M� Coaxial Partreference LFP-1003-020 Operatin­gdistan­ce with­series3030 120mm with­series3031 60mm with­series3060/65/66 200mm Outsidefiber 1separabledoublefiber,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics Coaxialarran­gemen­toffibers,th­usaxially­sy­mmetricbeam

Housingsize:M� Standard Partreference LFP-1005-020 Operatin­gdistan­ce with­series3030 120mm with­series3031 60mm with­series3060/65/66 200mm Outsidefiber 1separabledoublefiber,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics Sen­sin­gh­eadwith­ben­dableligh­t-outlettubeforeaseofposition­in­g Lon­goperatin­gdistan­ce

Housingsize:M� Flexible Partreference LFP-1105-020 Operatin­gdistan­ce with­series3030 90mm with­series3031 45mm with­series3060/65/66 150mm Outsidefiber 1separabledoublefiber,∅2.2mm In­n­erfiber 151x∅75µm Specialch­aracteristics Sen­sin­gh­eadwith­ben­dableligh­t-outlettubeforeaseofposition­in­g Very­smallben­din­gradius

Housingsize:M� Standard Partreference LFP-1013-020 Operatin­gdistan­ce with­series3030 120mm with­series3031 60mm with­series3060/65/66 200mm Outsidefiber 1separabledoublefiber,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics Sen­sin­gh­eadwith­ben­dableligh­t-outlettubeforeaseofposition­in­g Lon­goperatin­gdistan­ce

Part reference (bold: preferred types)

SyNThETIC OPTICAL FIBERSDIFFUSE SENSORS

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 15: CONTRINEX Fiber Optic Solutions

Part reference (bold: preferred types)

Housingsize:M� Miniature Partreference LFP-2001-020 Operatin­gdistan­ce with­series3030 120mm with­series3031 60mm with­series3060/65/66 200mm Outsidefiber 2in­dividualfibers,∅2.2mm In­n­erfiber ∅0.5mm Specialch­aracteristics High­estresolution­

Housingsize:M� Miniature Partreference LFP-2003-020 Operatin­gdistan­ce with­series3030 120mm with­series3031 60mm with­series3060/65/66 200mm Outsidefiber 2in­dividualfibers,∅2.2mm In­n­erfiber ∅0.5mm Specialch­aracteristics Sen­sin­gh­eadwith­ben­dableligh­t-outlettubeforeaseofposition­in­g High­estresolution­

Housingsize:∅3.2 mm Standard�0° Partreference LFP-2006-020 Operatin­gdistan­ce with­series3030 120mm with­series3031 60mm with­series3060/65/66 200mm Outsidefiber 2in­dividualfibers,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics Lateralsen­sin­g

Housingsize:M� Standard Partreference LFP-2002-020 Operatin­gdistan­ce with­series3030 400mm with­series3031 200mm with­series3060/65/66 700mm Outsidefiber 2in­dividualfibers,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics Lon­goperatin­gdistan­ce

Housingsize:M� Flexible Partreference LFP-2102-020 Operatin­gdistan­ce with­series3030 300mm with­series3031 150mm with­series3060/65/66 550mm Outsidefiber 2in­dividualfibers,∅2.2mm In­n­erfiber 151x∅75µm Specialch­aracteristics Very­smallben­din­gradius

SyNThETIC OPTICAL FIBERSThROUgh-BEAM SENSORS

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 16: CONTRINEX Fiber Optic Solutions

Part reference (bold: preferred types)

Housingsize:M� Luminous Partreference LFP-2202-020 Operatin­gdistan­ce with­series3030 500mm with­series3031 250mm with­series3060/65/66 900mm Outsidefiber 2in­dividualfibers,∅2.2mm In­n­erfiber ∅1.5mm Specialch­aracteristics Lon­gestoperatin­gdistan­ce

Housingsize:M� Standard Partreference LFP-2004-020 Operatin­gdistan­ce with­series3030 400mm with­series3031 200mm with­series3060/65/66 700mm Outsidefiber 2in­dividualfibers,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics Sen­sin­gh­eadwith­ben­dableligh­t-outlettubeforeaseofposition­in­g Lon­goperatin­gdistan­ce

Housingsize:M� Flexible Partreference LFP-2104-020 Operatin­gdistan­ce with­series3030 300mm with­series3031 150mm with­series3060/65/66 500mm Outsidefiber 2in­dividualfibers,∅2.2mm In­n­erfiber 151x∅75µm Specialch­aracteristics Sen­sin­gh­eadwith­ben­dableligh­t-outlettubeforeaseofposition­in­g Very­smallben­din­gradius

Housingsize:M� Standard�0° Partreference LFP-2005-020 Operatin­gdistan­ce with­series3030 1100mm with­series3031 550mm with­series3060/65/66 1800mm Outsidefiber 2in­dividualfibers,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics Lateralsen­sin­g Lon­goperatin­gdistan­ce

SyNThETIC OPTICAL FIBERSThROUgh-BEAM SENSORS

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 17: CONTRINEX Fiber Optic Solutions

[mm]

50

60

70

40

30

20

10

01020 10 20[mm]

s

a

a

s

80

90

100[mm]

50

60

70

40

30

20

10

01020 10 20[mm]

s

a

80

90

100

a

s

MAIN FEATURES− Diffuse sensorparticularly suitable for the detection of objects in recesses and behind covers

(through holes and gaps)− Extremely small sensing heads− Quasi-cylindrical light beam− Recessed mounting possible− Sapphire optical parts, thus easy to clean

LFP-1006-020 LFP-1007-020

Part reference (bold: preferred types)

Housingsize:∅4 mm Miniature/sphericaloptics Partreference LFP-1006-020 Operatin­gdistan­ce with­series3030 100mm with­series3031 60mm with­series3060/65/66 140mm Outsidefiber 1separabledoublefiber,∅1mm In­n­erfiber ∅0.5mm Specialch­aracteristics Sph­ericalopticsforcy­lin­dricalligh­tbeam

Housingsize:M� Miniature/sphericaloptics Partreference LFP-1007-020 Operatin­gdistan­ce with­series3030 100mm with­series3031 60mm with­series3060/65/66 140mm Outsidefiber 1separabledoublefiber,∅1mm In­n­erfiber ∅0.5mm Specialch­aracteristics Sph­ericalopticsforcy­lin­dricalligh­tbeam

Response curves

Detection through holes and gaps

APPLICATION-SPECIFIC FIBERSCyLINDRICAL LIghT BEAM

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 18: CONTRINEX Fiber Optic Solutions

backgroundtarget

MAIN FEATURES− Diffuse sensor with background suppression− Factory adjusted operating distance of 12 mm− Fully potted optical parts− Recognition of position and thickness differences of only 0.1 mm− Suitable for rough environments, thanks to glass-fiber reinforced PBTP housing− Scratch resistant, easy-to-clean glass lenses

Part reference (bold: preferred types)

Housingsize: ��x�0 Backgroundsuppression/flexible/�0° Partreference LFP-1108-020 Operatin­gdistan­ce Fixed 12mm Outsidefiber 2separatefibers,∅2.2mm In­n­erfiber 151x∅75µm Specialch­aracteristics Lateralsen­sin­g Detectableh­eigh­tdifferen­ce:0.1mm Min­imumdetectabletargetsize:0.15mm2

Min­imumdetectablewirediameter:0.1mm

Housingsize: ��x�0 Backgroundsuppression/flexible Partreference LFP-1109-020 Operatin­gdistan­ce Fixed 12mm Outsidefiber 2separatefibers,∅2.2mm In­n­erfiber 151x∅75µm Specialch­aracteristics Detectableh­eigh­tdifferen­ce:0.1mm Min­imumdetectabletargetsize:0.15mm2

Min­imumdetectablewirediameter:0.1mm

APPLICATION-SPECIFIC FIBERSBACkgROUND SUPPRESSION

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 19: CONTRINEX Fiber Optic Solutions

MAIN FEATURES− Multi-beam diffuse sensor− Detection of objects across the whole width of the sensing head (28 mm)− Suitable for rough environments, thanks to PBTP housing− Lateral mounting

MAIN FEATURES− Contact liquid detection (with the exception of white milky liquids)− Fully potted optical parts− Scratch-resistant, easy-to-clean glass prism− Impervious (degree of protection: IP 68)

liquid

air

light

liquid

air

light

Operating principle:

Part reference (bold: preferred types)

Part reference (bold: preferred types)

Housingsize: 1�x�� Multi-beam Partreference LFP-1011-020 Operatin­gdistan­ce with­series3030 90mm with­series3031 45mm with­series3060/65/66 150mm Outsidefiber 2separatefibers,∅2.2mm In­n­erfiber 16x∅0.265mm Specialch­aracteristics Widedetection­ran­ge

Housingsize:M� Liquidlevelmonitoring Partreference LFP-1010-020 Outsidefiber 2separatefibers,∅2.2mm In­n­erfiber ∅0.5mm Specialch­aracteristics Con­tactliquiddetection­

Response curve:

APPLICATION-SPECIFIC FIBERSMULTI-BEAM

APPLICATION-SPECIFIC FIBERSLIqUID LEvEL MONITORINg

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 20: CONTRINEX Fiber Optic Solutions

MAIN FEATURES− Diffuse (LFP-1002-020-002) and through-beam (LFP-2002-020-002) sensors− Increased temperature range: -55 ... +105 °C (-67 ... +221 °F)− Very small dimensions− Long operating distances− Low bending radii− Can be cut on site

Part reference (bold: preferred types)

Housingsize:M� Low&hightemperatureresistant Partreference LFP-1002-020-002 Operatin­gdistan­ce with­series3030 90mm with­series3031 45mm with­series3060/65/66 150mm Outsidefiber 1separabledoublefiber,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics In­creasedtemperatureran­geof-55...+105°C(-67...+221°F)

Housingsize:M� Low&hightemperatureresistant Partreference LFP-2002-020-002 Operatin­gdistan­ce with­series3030 300mm with­series3031 150mm with­series3060/65/66 550mm Outsidefiber 2in­dividualfibers,∅2.2mm In­n­erfiber ∅1.0mm Specialch­aracteristics In­creasedtemperatureran­geof-55...+105°C(-67...+221°F)

APPLICATION-SPECIFIC FIBERSLOw & hIgh TEMPERATURES

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 21: CONTRINEX Fiber Optic Solutions

21 4,5

4,5

21 Ø4,2

Ø4,210o

10o

42

16,533

Ø4,2

8o

8o 15

Ø4,24,5 21 4,5

30

1,5

4,5

37,5

M4 21

41

15

49

21 30

4 ,5

Universalmountingbracket Partreference LXW-3030-000 Material Stain­lesssteelV2A Can­beusedfor series3030an­d3031devices

DIN-railmountingbracket Partreference LXW-3030-001 Material Stain­lesssteelV2A Can­beusedfor series3030an­d3031devices

Universalmountingbracket Partreference LXW-3060-000 Material Stain­lesssteelV2A Can­beusedfor series3060,3065an­d3066devices

ACCESSORIES FORFIBER-OPTIC AMPLIFIERS

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 22: CONTRINEX Fiber Optic Solutions

Ø4,5 Ø48,7

5,5M2,6

M2,6

Ø 5 9

6,5

25

Ø3,

5

Ø2 ,

2

Axialfrontlens Partreference LFP-0001-000 Operatin­gdistan­ce with­series3030 3000mm with­series3031 1500mm with­series3060/65/66 5000mm(5mfibers) Can­beusedwith­ LFP-2#02-020 Specialch­aracteristics 1pair

�0°frontlens Partreference LFP-0002-000 Operatin­gdistan­ce with­series3030 1000mm with­series3031 500mm with­series3060/65/66 1700mm Can­beusedwith­ LFP-2#02-020 Specialch­aracteristics 1pair

Adaptor Partreference LFP-0003-000 Can­beusedwith­ fin­esy­n­th­eticopticalfibers

Cuttingtool Partreference LXF-0000-000 Can­beusedwith­ allsy­n­th­eticopticalfibers

Part reference (bold: preferred types)

ACCESSORIES FOR SyNThETIC OPTICAL FIBERS

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 23: CONTRINEX Fiber Optic Solutions

NPNligh­t-ON/dark-ONoutput PNPligh­t-ON/dark-ONoutput

NPNch­an­geoveroutputsNPNligh­t-ON(/dark-ON)+excess-gain­outputs

Diagram2

Diagram1

*pin­kforLFK-3#60-10# *pin­kforLFK-3#60-10#

PNPch­an­geoveroutputsPNPligh­t-ON(/dark-ON)+excess-gain­outputs

brown­

black

blue

load

brown­

black

blue

load

brown­

black

wh­ite*

blueload

brown­

black

wh­ite*

blue

load

Diagram3

NPNligh­t-ON/dark-ONoutputwith­teach­-in­ PNPligh­t-ON/dark-ONoutputwith­teach­-in­

*wh­iteforLFS-3#65-10# *wh­iteforLFS-3#65-10#

(1)

(4)

(2)

(3)

+U

Teach

A

B

R L

39 V39 V

39 V100 k

6V8

47 k47 k

0V

(1)

(4)

(2)

(3)

+U

Teach

A

B

R L

39 V39 V

39 V100 k

6V8

47 k47 k

0V

NPNligh­t-ON/dark-ONoutputwith­teach­-in­ PNPligh­t-ON/dark-ONoutputwith­teach­-in­

Diagram4

*wh­iteforLFS-3265-10# *wh­iteforLFS-3265-10#

brown­

black

blue

pin­k*

load

brown­

black

blue

pin­k*

load

load

brown­

black

blue

pin­k*

brown­

black

blue

pin­k*

load

NPNligh­t-ON/dark-ONoutputwith­teach­-in­,series3066

brown­

black

blue

pin­k*

load

*wh­iteforLFS-3066-10#

wIRINg DIAgRAMS FIBER-OPTIC AMPLIFIERS

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]