  • 8/16/2019 Control and Management Presentation

    1/41

    Control & Management

    Solutions 

  • 8/16/2019 Control and Management Presentation

    2/41

    There are various ways to control differentequipment types and site conditions:

    • Dry controls• Measurements• Environment• Sensors / detectors•

     Communication• UPS and DC Systems

    Control & Management 

  • 8/16/2019 Control and Management Presentation

    3/41

    Equipment control

    Air Conditioners

    Older telecomequipment

    Manufacturing

    Access

    Generators

  • 8/16/2019 Control and Management Presentation

    4/41

    • Check status and control operation of air conditioners.• Control industrial or custom process, like switching

    cooling fan on when internal street cabinettemperature gets too high.

    Control older UPS and DC systems through their drycontact connection controls.• Check and operate generators using it’s control panel. • Access (barrier, gate, door) control via SMS or calls,

    with access database.

    • Remote control of all equipment by Internet or SMS.• Automatic response actions for situation changes.• Notifications on e-mail and/or SMS about all

    events.

    Equipment Control 

  • 8/16/2019 Control and Management Presentation

    5/41

     

    Electricity measurement

    Special low voltage sensors

    Current

    FrequencyKWH meters

    Voltage

  • 8/16/2019 Control and Management Presentation

    6/41

     

    Electricity measurement

    Measurement 

    Without adaptor  

    With adaptor  

     Adaptor type 

     AC voltage (V) 

    0÷40  0÷450  Transducer  

    DC voltage (V)  ± 0÷60  ± 0÷450  Transducer  

     AC current (A) 

    0÷100  Current transformer  

    DC current  60mV measurement  DC Shunt 

    DC current (A)  0÷100  Hall sensor  

    Frequency (Hz) 

    45÷65 (up to 40v) 

    45÷65 

    Transducer  

    Various electrical measurements are supported. transducersless-High voltages require external transformer

    that lower high voltages to

  • 8/16/2019 Control and Management Presentation

    7/41

     

    Environment and more

    Temperature

    Fuel level

    Humidity

    Gas

  • 8/16/2019 Control and Management Presentation

    8/41

     

    Environment & More 

    Humidity and temperature sensors can be installed andmonitored.Thresholds and hysteresis levels for alarms areconfigurable.Wide list of generic sensors can be connected andmonitored as well, operating at 0÷5Vdc or 0÷60mVdc.Generic sensors include gas, fluid level in a tank, liquidflow, lighting, process control and more.

  • 8/16/2019 Control and Management Presentation

    9/41

     

    Sensors & Detectors 

    Smoke detectors Water detectors

    Motion detectors Door/window detectors

    Process micro switch control

  • 8/16/2019 Control and Management Presentation

    10/41

     

    Sensors & Detectors 

    Security alarms can be sent based on events generated by smoke,water, flame, intruder, and motion detectors.Any detector with dry contact indication can be connected.Auxiliary operation voltage might be required by some types ofdetectors.

     

  • 8/16/2019 Control and Management Presentation

    11/41

     

    IT Control IT Control

    ServersSwitches /

    Routers

    Workstations

    Network printers

  • 8/16/2019 Control and Management Presentation

    12/41

    • Servers, workstations, routers, switches, networkprinters, hardware firewalls and spam filters, and anyother device with Ethernet connection can all becontrolled by the IT Control feature.

    • Devices supporting SNMP (Simple NetworkManagement Protocol) provide various statusinformation: CPU load, hard drive space, physical andvirtual memory, installed software, and list of runningprocesses.

    • Detailed information can be viewed remotely.• Windows servers shutdown is integrated through free

    client software.• Manual and automatic LAN wakeup function is

    implemented.

    IT Control 

  • 8/16/2019 Control and Management Presentation

    13/41

     

    UPS & DC Systems 

    Other manufacturer’s UPS

    PS1006 DC System

    Small UPS systems

    µPS-SP Industrial UPS

    Power+ Modular UPS

  • 8/16/2019 Control and Management Presentation

    14/41

     

    UPS & DC Systems 

    Gamatronic UPS and DC Systems can be monitoredthrough RS-232 serial communication port.Notifications and alarms can be sent on SMS, e-mail, drycontacts.Full information about UPS status and operation on the

    web interface.Remote control actions (shutdown, load on bypass…).Computers shutdown due to power failure or low batterycondition.Computer wake up after power failure.Some other manufacturer’s UPS and DC Systems

     are supported. 

  • 8/16/2019 Control and Management Presentation

    15/41

     

    Practical Applications theDatacenter

     

    Water was detected under the raised floor in unmannedcomputer room by water leakage detector. What can beautomatically done to minimize the damage? 1.  Send SMS notification to relevant people

    2.  Send shutdown signal to all servers3.  Operate local audio alarm by means of dry contact4.  Wait for emergency service

  • 8/16/2019 Control and Management Presentation

    16/41

     

    Practical ApplicationsUnmanned Site

     

    Thousand of cellular sites consume power, need securitysystem and environmental controls. Only for knowingelectricity consumption, personnel is being sent to everysite once a month. How to minimize overall cost?

    1. Management and Control unit is installed2. All site parameters are monitored and reported3. Emergency actions are programmed4. Site access can be controlled5. KWH meters power consumption is

    accessible remotely

  • 8/16/2019 Control and Management Presentation

    17/41

     

    Practical Applications Accessto Control 

    Medium sized company has about 200 employees entering theunderground parking every day. Electronic barrier controls entry. Howto automate entry process without implementing expensive tagsecurity system?

    1. C&M unit is installed inside the barrier mechanism2. Build internal database with employee’s phone numbers 3. In front of the barrier, they just dial in from the mobile4. The gate will open by recognizing their phone number5. The phone call will not be answered

    by the unit, no cost since there wasno conversation

  • 8/16/2019 Control and Management Presentation

    18/41

     

    Gamatronic C& M Solutions:WING 

    WING is a simple cellular communication device. Itis being installed on UPS and DC systems, andprovides SMS alarms to the end user or controlcenters. On Power+ UPS, for example, the unit’snetwork board will automatically detect and startusing the newly attached cellular modem forcommunication. Recipient's phone numbers areeasily added through the user friendly web interface.

  • 8/16/2019 Control and Management Presentation

    19/41

     

    Gamatronic C&M Solutions:WING 

    12vDC operating voltage can be taken either from Power+ System Controllerauxiliary voltage connector for battery backup, or from a provided 12v AC/DCadaptor. SIM card is required for operation, quad-band GSM modem providesworldwide cell network coverage.

    Supported products: DC Power Systems: PS1006, PS2012, 1UDC+ UPS Systems: µPS-SP, MST, Power+, Power+ SA

    SIM card is required

    for GSM communication,

    such as SMS or GPRS

  • 8/16/2019 Control and Management Presentation

    20/41

     

    Gamatronic C&M Solutions:G4 

    G4 is a sophisticated control and management solution that includesembedded software with web interface and wide list of equipmentmonitoring options.

    • It can be installed as an added value for UPS or DC system, or just as a stand-alonesite controller.

    • Fully configurable and programmable interface makes this unit highly flexible to fitany site and application.

    • Available in stand-alone or 19” rack mountable versions. 

  • 8/16/2019 Control and Management Presentation

    21/41

     

    Gamatronic C&M Solutions:G4 

    Front panel includes:

    Network connection

    Extra RS-232 output (usually disabled)IndicatorsSIM card slotReset buttons

  • 8/16/2019 Control and Management Presentation

    22/41

     

    Gamatronic C&M Solutions:G4 

    Rear panel 12vDC connection includes:

    Dry input contacts

    Changeover dry output contactsTemperature sensors connector (adaptor board included)RS-232 serial communication portCellular antenna connection

    Temperature

    sensor:

  • 8/16/2019 Control and Management Presentation

    23/41

     

    Gamatronic C&M Solutions:G4 

    G4 operates with dry contacts and temperaturemeasurements for environment and equipmentcontrol. It can also communicate with a power devicethrough RS232 serial communication port, and monitor

    computer equipment via the IT Control (Ethernetconnection).

    Connection Amount Remark

    Dry inputs 8 N.O. / N.C. programmable

    Dry outputs 4 Changeover (N.O. / COM. / N.C.)Temperature 5 One sensor is included with the unit

    RS-232 1 UPS / DC system comms., several protocols

    Ethernet 1 Web / SNMP communication + IT Control

  • 8/16/2019 Control and Management Presentation

    24/41

     

    Gamatronic C&M Solutions:G4 Web Interface 

    Configuration and programming of G4 is performed through webinterface, no software is required:

  • 8/16/2019 Control and Management Presentation

    25/41

    Gamatronic C&M Solutions:G4 Web Interface 

    IT Control monitors any equipment with IP address, andshows verbose information for SNMP-enabled devices:

  • 8/16/2019 Control and Management Presentation

    26/41

     

    Gamatronic C&M Solutions:G4 Web Interface 

    Serial device configuration helps to access all supportedtypes of equipment with auto-detect feature:

  • 8/16/2019 Control and Management Presentation

    27/41

     

    Gamatronic C&M Solutions:G4 Web Interface 

    SMS notifications will be sent to specified cellularnumbers, and according to the event type:

  • 8/16/2019 Control and Management Presentation

    28/41

     

    Gamatronic C&M Solutions:G4 Web Interface 

    The G4 will also accept external control through SMSmessaging and reply to the initiator:

  • 8/16/2019 Control and Management Presentation

    29/41

     

    Gamatronic C&M Solutions 

    G-Eye is the fully featured Site Manager. Monitoring and control optionsare extended compared with the G4. It also shows great emergency  performance with it’s internal backup battery and front panel LCD. 

    Complete site monitoring includes more features, like KWH meters andpower measurements.

    Additional environmental control features include more options.19” design to suit standard mounting equipment.

  • 8/16/2019 Control and Management Presentation

    30/41

     

    Gamatronic C&M Solutions 

    Connection Amount Remark

    Dry inputs 32 NO/NC programmable

    Dry outputs 16 Changeover

    Temperature 4 One sensor includedRS-232 1 UPS / DC system monitoring

    Ethernet 1 Communication + IT Control

     AC or DC volts / AC or DC amps 12 Transducer required > 40v/60vDC

    Isolated DC volts / DC amps 4 Up to 60v or 60mV shunt

    Frequency 2 Transducer required > 40v

    kWH metering 2 Pulse reading only

    Humidity 2 Precise 0÷100% measurement

    Flood (with aux. voltage) 1 Special sensors available

    Liquid level 1 Various sensors exist on market

  • 8/16/2019 Control and Management Presentation

    31/41

     

    Gamatronic C&M Solutions Servers

    Telecom equipmentAir conditioners

    UPS

    DC Power

    Measurements

    Fuel level

    Diesel generators

    Safety kWH

  • 8/16/2019 Control and Management Presentation

    32/41

     

    Gamatronic C&M Solutions 

    • With the G-Eye on the site, you receive the mostcomplete data including live electricity measurements.

    • All this without unnecessary complications and costs

    involved in installation and maintenance.• All programming and fine tuning are performed

    remotely, without loosing the control even for aminute.

    • Universal input power and the backup battery features

    will ensure that appropriate procedures will beexecuted and alarms sent even during total siteblackout.

    • Security is maintained by password protection on theweb interface. No actions can be carried out withoutauthentication.

  • 8/16/2019 Control and Management Presentation

    33/41

     

    Gamatronic C&M Solutions:G-Eye Web Interface 

    G-Eye electricity measurements are highlyconfigurable, all of them include high/low alarms andhysteresis.

  • 8/16/2019 Control and Management Presentation

    34/41

     

    Gamatronic C&M Solutions:G-Eye Web Interface 

    All connected measurements must be calibrated carefully uponinstallation in order to achieve correct figures.

  • 8/16/2019 Control and Management Presentation

    35/41

     

    Gamatronic C&M Solutions:G-Eye Web Interface 

    Internal log of events can be downloaded in MS Excelformat for additional processing.

  • 8/16/2019 Control and Management Presentation

    36/41

     

    Gamatronic C&M Solutions: G-Eye Web

    Interface 

    Internal log of events can be downloaded in MS Excelformat for additional processing.

  • 8/16/2019 Control and Management Presentation

    37/41

     

    Gamatronic C&M Solutions:Management Software 

    Control centers require global centralized control overlarge amount of units and/or sites. GEMSi software isdesigned for both large control centers and compact, in-company monitoring.

    GamatronicElementManagementSystem

    innovated

    i l i

  • 8/16/2019 Control and Management Presentation

    38/41

     

    Gamatronic C&M Solutions:Management Software 

    • Secure user-controlled interface with action loggingallows direct access to regions and sites, either oncountry/county or factory/room level.

    • All Gamatronic and supported non-Gamatronic units canbe put on one screen.

    • Alarms pop up and logged for all units, with user-defined severity.• Data logging is supported for detailed tracking of

    problematic site conditions.• Unlimited event logging.•

    Powerful, fully configurable reports generation supportsexcel output format.• Database backup/restore feature.• Includes all Gamatronic communication software.

    G i C& S l i

  • 8/16/2019 Control and Management Presentation

    39/41

     

    Gamatronic C&M Solutions:Management Software 

    Easy map oriented navigation makes control simple andintuitive.

    G i C&M S l i

  • 8/16/2019 Control and Management Presentation

    40/41

     

    Gamatronic C&M Solutions:Management Software 

    Built in browser shows real-time data within GEMSi,

    without the need to open external windows.

  • 8/16/2019 Control and Management Presentation

    41/41

     Gamatronic hardware and software Control & Management solutionskeep you confident and your site safe wherever you are at all times.