control rod drive system (prd) overview
DESCRIPTION
Control Rod Drive System (PRD) Overview. P. J. Sebastiani University of Pittsburgh ME 2120 February 7, 2011. Control Rod Drive System (PRD) Agenda. Purpose of the System Background Required Outputs Initial Conditions Time-Dependent Boundary Conditions Required Geometry Pertinent Physics - PowerPoint PPT PresentationTRANSCRIPT
1
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD) Overview
● P. J. Sebastiani● University of Pittsburgh ME 2120● February 7, 2011
2
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Agenda
● Purpose of the System● Background● Required Outputs● Initial Conditions● Time-Dependent Boundary Conditions● Required Geometry● Pertinent Physics● Viewable Signals
3
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Purpose of the SystemReactivity Control
– The reactor core utilizes Rod Cluster Control Assemblies which provide reactivity control for:
– Rapid shutdown (i.e., reactor trip)
– Reactivity changes due to temperature changes with power (i.e., power defect)
– Reactivity changes due to coolant temperature changes in the power range (i.e., moderator temperature feedback)
– Reactivity changes due to void formation
4
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)BackgroundRod Cluster Control Assemblies (RCCAs)
– RCCAs consists of absorber rods attached to a spider connector which, in turn, is connected to a drive shaft.
– RCCA control elements consist of cylindrical neutron absorber rods (control rods).
– The control rods extend the full length of the core when fully inserted.
– The RCCAs are arranged into groups and electrically interconnected so that the entire group moves together.
– Reactivity of the core is changed by raising or lowering a group within the core.
5
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Background (continued)RCCA Diagram (within Fuel Assembly)
6
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Background (continued)RCCA Groups in the Core
NOTE: AP1000 will have a different rod pattern
7
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Background (continued)Control Rod Drive Mechanism
– The RCCAs are positioned by latch-type magnetic jack control rod drive mechanisms (CRDMs) mounted on the reactor vessel head
– Used to raise and lower the RCCAs (in/out of core)
– Instantly releases RCCAs when necessary for rapid reactor shutdown (i.e., Reactor Trip)
– Latch positions are referred to as “steps”
– Stepping distance: 5/8 inch (in)
– Total rod position indication length: ~230 steps (~144 in)
– Maximum Rods Move Speed: 45 inch/min (72 steps/min)
8
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Required OutputsRods Move Speed
– Manual Control (default setting): 48 steps/min
– Automatic Control: up to 72 steps/min (see Pertinent Physics Section)
Rods Move Direction– In or Out
9
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Initial ConditionsControl Scheme
– Automatic or Manual ControlRod Insertion Limits
– Technical Specification Limits on rod position to ensure adequate Shutdown Margin for the core
Rod Position– The current rod position at the start of the simulation
10
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Time-Dependent Boundary ConditionsCore Average Temperature (TAVG)
– Calculated using cold leg (TCOLD) and hot leg (THOT)
temperature values
– Input to the “Temperature Error” signalReactor Power (2 separate inputs)
– One input from Turbine Impulse Pressure (for Temperature Error calculation)
– Will this be available in PANTHER model?
– One input from Power Range Detector (for Power Mismatch calculation)
11
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Time-Dependent Boundary Conditions (cont.)
Trip Breaker Setting– i.e., Manual Reactor Trip
– Open or Closed
12
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Required GeometryControl Rod Pattern
– See Background Section for example
13
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Pertinent PhysicsTotal Error Calculation
14
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Pertinent PhysicsRods Move Speed
Deadband
Inward Motion
Total Error (TRef - TAvg)
Outward MotionSpeed
72 spm
40 spm
8 spm
-5.0 -3.0 -1.5 0 +1.5 +3.0 +5.0 F
LockupLockup
º
15
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
Control Rod Drive System (PRD)Viewable SignalsControl Scheme Selection
– AUTO or MANUAL
Rod Position (steps withdrawn)
Rod Speed (steps/min)
Total Error
Rods Move Indication
– Lamp for moving or not moving
– “Clicking” noise during rod movement
16
© 2011 Westinghouse Electric Company LLC. All Rights Reserved.Westinghouse Non-Proprietary Class 3
End of Presentation