copper tubes - astm b88
TRANSCRIPT
![Page 1: Copper Tubes - ASTM B88](https://reader035.vdocument.in/reader035/viewer/2022072921/55372a1c4a79594b218b4c4e/html5/thumbnails/1.jpg)
Copper Tubes - ASTM B88Copper Water and Gas Tube according ASTM B 88 - imperial units
Sponsored Links
Dimensions of copper tubes according ASTM B88 STANDARD SPECIFICATION FOR SEAMLESS COPPER WATERTUBE can be found in the table below:
Copper tubes of type K are thick walled, much thicker than type L and M and are used for domestic water-, serviceand distribution-, fire protection-, solar-, fuel and oil-, HVAC-, compressed air-, natural gas-, oxygen-, LPG gas-, snowmelting-, steam- and vacuum-systems.
Copper tubes of type K can be used sweat, flared and compression fittings. Available in hard and soft types.
The Engineering ToolBox WebSearch
Type K
NominalSize
(inches)
Actual OutsideDiameter(inches)
Tolerance on OutsideDiameter(inches)
Wall Thickness(inches) Weight
(lb/ft)
Annealed1) Drawn2) Nominal Tolerance
1/4 3/8 0.375 0.002 0.001 0.035 0.0035 0.133
3/8 1/2 0.500 0.0025 0.001 0.049 0.005 0.269
1/2 5/8 0.625 0.0025 0.001 0.049 0.005 0.344
5/8 3/4 0.750 0.0025 0.001 0.049 0.005 0.418
3/4 7/8 0.875 0.003 0.001 0.065 0.006 0.641
1 1 1/8 1.125 0.0035 0.0015 0.065 0.006 0.837
1 1/4 1 3/8 1.375 0.004 0.0015 0.065 0.006 1.04
1 1/2 1 5/8 1.625 0.0045 0.002 0.072 0.007 1.36
2 2 1/8 2.125 0.005 0.002 0.083 0.008 2.06
2 1/2 2 5/8 2.625 0.005 0.002 0.095 0.010 2.92
3 3 1/8 3.125 0.005 0.002 0.109 0.011 4.00
3 1/2 3 5/8 3.625 0.005 0.002 0.120 0.012 5.12
4 4 1/8 4.125 0.005 0.002 0.134 0.013 6.51
5 5 1/8 5.125 0.005 0.002 0.160 0.016 9.67
6 6 1/8 6.125 0.005 0.002 0.192 0.019 13.87
Type L
NominalSize
(inches)
Actual OutsideDiameter(inches)
Tolerance on OutsideDiameter(inches)
Wall Thickness(inches) Weight
(lb/ft)
Annealed1) Drawn2) Nominal Tolerance
1/4 3/8 0.375 0.002 0.001 0.030 0.003 0.126
3/8 1/2 0.500 0.0025 0.001 0.035 0.004 0.198
1/2 5/8 0.625 0.0025 0.001 0.040 0.004 0.285
5/8 3/4 0.750 0.0025 0.001 0.042 0.004 0.362
3/4 7/8 0.875 0.003 0.001 0.045 0.004 0.455
1 1 1/8 1.125 0.0035 0.0015 0.050 0.005 0.655
1 1/4 1 3/8 1.375 0.004 0.0015 0.055 0.006 0.884
1 1/2 1 5/8 1.625 0.0045 0.002 0.060 0.006 1.14
Tube/Pipe Bender ToolingFull Service Bender Tooling MfgTube Bending, End-Forming Etc.www.EatonLeonardTooling.com
Piping Analysis SoftwarePipe Flow Network Analysis &System Modeling. Download AWorking Demo!www.AFT.com/WaterHammer
China Seamless steel pipeQuality seamless steel pipe here ,All specifications you need.Order!www.stwfgg.com
Ads by Google Copper Tube Fittings Steel Tube Bending Copper Pipe Bender Air Fittings Fitting Dimensions
Resources, Tools and Basic Information for Engineering and Design of Technical Applications!
Page 1 of 4Copper Tubes - ASTM B88
2009/10/26http://www.engineeringtoolbox.com/astm-copper-tubes-d_779.html
![Page 2: Copper Tubes - ASTM B88](https://reader035.vdocument.in/reader035/viewer/2022072921/55372a1c4a79594b218b4c4e/html5/thumbnails/2.jpg)
Standard copper tubes of type L are used for interior above ground plumbing - domestic water-, service anddistribution-, fire protection-, solar-, fuel and oil-, HVAC-, compressed air-, natural gas-, LPG gas-, snow melting- andvacuum-systems.
Copper tubes of type L can be used with sweat, compression and flare fittings. Only seat and flare fittings are legal forgas lines. Available in hard and soft types.
Copper tubes of type M are used for interior domestic water-, service and distribution-, fire protection-, solar-, fuel andoil-, HVAC-, snow melting- and vacuum-systems. Wall thickness less than type K and L.
Copper tubes type M are normally used with flare fittings. Available in soft and hard types.
1 in (inch) = 25.4 mm
1) Annealed tube is suitable for use with flared or compression fittings, and with solder-type fittings, provided roundingand sizing of the tube ends is performed where needed.
2) Drawn temper tube is suitable for use with solder-type fittings. Types A and B tube, in the drawn temper, aresuitable for use with certain types and sizes of compression fittings. The standard length for drawn tubes are 20 ft(6.096 m).
The B88 specification covers seamless copper water tube suitable for general plumbing, similar applications for theconveyance of fluids, and commonly used with solder, flared, or compression-type fittings. The type of copper watertube suitable for any particular application is determined by the internal or external fluid pressure, by the installationand service conditions, and by local requirements. Means of joining or bending are also factors that affect the selectionof the type of tube to be used.
This specification is the imperial companion of Specification B 88M.
Sponsored Links
Related Topics
Dimensions Sizes and dimensions of pipes and tubes, and their fittings - inside and outside diameter, weight andmore
4 4 1/8 4.125 0.005 0.002 0.114 0.011 5.38
5 5 1/8 5.125 0.005 0.002 0.125 0.012 7.61
6 6 1/8 6.125 0.005 0.002 0.140 0.014 10.20
Type M
NominalSize
(inches)
Actual OutsideDiameter(inches)
Tolerance on OutsideDiameter(inches)
Wall Thickness(inches) Weight
(lb/ft)
Annealed1) Drawn2) Nominal Tolerance
1/4 3/8 0.375 0.002 0.001 0.106
3/8 1/2 0.500 0.0025 0.001 0.025 0.002 0.144
1/2 5/8 0.625 0.0025 0.001 0.028 0.003 0.203
5/8 3/4 0.750 0.0025 0.001 0.263
3/4 7/8 0.875 0.003 0.001 0.032 0.003 0.328
1 1 1/8 1.125 0.0035 0.0015 0.035 0.004 0.464
1 1/4 1 3/8 1.375 0.004 0.0015 0.042 0.004 0.681
1 1/2 1 5/8 1.625 0.0045 0.002 0.049 0.005 0.94
2 2 1/8 2.125 0.005 0.002 0.058 0.006 1.46
2 1/2 2 5/8 2.625 0.005 0.002 0.065 0.006 2.03
3 3 1/8 3.125 0.005 0.002 0.072 0.007 2.68
3 1/2 3 5/8 3.625 0.005 0.002 0.083 0.008 3.58
4 4 1/8 4.125 0.005 0.002 0.095 0.010 4.66
5 5 1/8 5.125 0.005 0.002 0.109 0.011 6.66
6 6 1/8 6.125 0.005 0.002 0.122 0.012 8.91
F.R.W Carobronzespecialiste bronze et alliages FrenchBronze and alloys specialistwww.frwcarobronze.fr
Tube Bending and AssemblyFluid Handling Products,CNCBending Metal,Rubber,Plastic Hoseformingwww.tubemasters.co.uk
High Speed Over CopperCopper Fibre Channel TransceiversEthernet SFP, XFP, X2, CX4,Cageswww.MethodeDataMate.com
Page 2 of 4Copper Tubes - ASTM B88
2009/10/26http://www.engineeringtoolbox.com/astm-copper-tubes-d_779.html
![Page 3: Copper Tubes - ASTM B88](https://reader035.vdocument.in/reader035/viewer/2022072921/55372a1c4a79594b218b4c4e/html5/thumbnails/3.jpg)
Copper Tubes to BS (British Standard) 2871 - Dimensions and Working Pressures Metric Sizes of copper tubes toBS (British Standard) 2871:1972
Copper Tubes - Dimensions and Working Pressures Dimensions and working pressures of copper tubesaccording BS (British Standard) 2871:1972
Difference between Pipes and Tubes Pipes and tubes are not the same
Heat Carrying Capacity of Copper Tube Hot water heat carrying capacity of copper tube type L
Copper Tubes - ASTM B88M Copper Water and Gas Tube according ASTM B 88M - metric units
Comparing Friction Loss in Steel, Copper and Plastic Pipes Water flow and friction head loss (ft/100 ft) - steel,copper and PVC plastic pipes
Hot Bending - Copper and Copper Alloy Pipe Temperature range for bending copper pipe and tube
Pressure Loss of Water Due to Friction in Copper Tubes Pressure Loss (psi/ft) of Water Due to Friction in CopperTubes Types K, L and M Copper Tube - ASTM B88
Copper Pipe - Water Velocity Limits The water velocities in copper pipes should not exceed certain limits to avoiderosion
Copper Tubes DWV - Drain, Waste and Vent Dimensions of copper tube ASTM 306 DWV - Drain Waste and Vent
Sponsored Links
ToolBox Short List
Difficult to find your favorite ToolBox page? Add links to your favorite pages in your own personal Short List!
• Add this Page! • Delete the ShortList!
Engineering ToolBox - SketchUp Edition - Online 3D modeling!
Engineering ToolBox - SketchUp Edition - enabled for use with the amazing, fun and free Google SketchUp.
Search the ToolBox
Web The Engineering ToolBox
Translate the ToolBox
Arabic - Chinese (Simplified) - Chinese (Traditional) - Dutch - French - German - Italian - Japanese - Korean -Portuguese - Russian - Spanish
About the ToolBox
We appreciate any comments and tips on how to make The Engineering ToolBox a better information source. Pleasecontact us by email
if You find any faults, inaccuracies, or otherwise unacceptable information.
The content in The Engineering ToolBox is copyrighted but can be used with NO WARRANTY or LIABILITY. Important
Search
Sanxin Steel TubeHigh quality steel tubes from China,post your offer now!www.cnsteeltubes.com
Pipe polishing machineEffective solution for the removalrust and paint from a tube endwww.wortelboer.ws
Aluminium BronzeHigh Integrity Nickel-Ali BronzeEngineered to ASTM, BS, EN, AMSwww.copperalloys.net
Page 3 of 4Copper Tubes - ASTM B88
2009/10/26http://www.engineeringtoolbox.com/astm-copper-tubes-d_779.html
![Page 4: Copper Tubes - ASTM B88](https://reader035.vdocument.in/reader035/viewer/2022072921/55372a1c4a79594b218b4c4e/html5/thumbnails/4.jpg)
© The Engineering ToolBox 2005
9 10 13
Page 4 of 4Copper Tubes - ASTM B88
2009/10/26http://www.engineeringtoolbox.com/astm-copper-tubes-d_779.html