MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
COSMO36-IFT-B
Actual Framing Actual Framing Actual Framing Actual Framing32-1/4" x 15-1/4"
[819 x 387]41"[1041]
42"[1067]
30-3/4"[781]
42"*[1067]
33-11/16"[856]
32-3/4"[832]
17-3/4"[451]
17-3/4”[451]
16-3/4"[425]
32-3/8"[822]
2-3/16"[56]
6"[152]
17-1/4"[438]
25-7/8"[657]
43-1/2"[1105]
7-3/4"[197]
41" [1041]36" [914]
32-1/4" [819]
15-1/4"[387]
33-11/16"[856]
3-1/2"[89]
7"[178]
46-1/2"[1181]
9-13/16"[249]
17-3/4"[451]
1/2" [13]30-3/4"[781]
GAS LINE ACCESS
ELECTRICALACCESS
6-5/8" [168]
HEAT MANAGEMENT SYSTEMS ACCESS
10-3/8"[264]
7-1/2"[191] TOP VIEW
LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW
16-3/4"[425]
32-3/8"[822]
2-3/16"[56]
6"[152]
17-1/4"[438]
25-7/8"[657]
43-1/2"[1105]
7-3/4"[197]
41" [1041]36" [914]
32-1/4" [819]
15-1/4"[387]
33-11/16"[856]
3-1/2"[89]
7"[178]
46-1/2"[1181]
9-13/16"[249]
17-3/4"[451]
1/2" [13]30-3/4"[781]
GAS LINE ACCESS
ELECTRICALACCESS
6-5/8" [168]
HEAT MANAGEMENT SYSTEMS ACCESS
10-3/8"[264]
7-1/2"[191]
16-3/4"[425]
32-3/8"[822]
2-3/16"[56]
6"[152]
17-1/4"[438]
25-7/8"[657]
43-1/2"[1105]
7-3/4"[197]
41" [1041]36" [914]
32-1/4" [819]
15-1/4"[387]
33-11/16"[856]
3-1/2"[89]
7"[178]
46-1/2"[1181]
9-13/16"[249]
17-3/4"[451]
1/2" [13]30-3/4"[781]
GAS LINE ACCESS
ELECTRICALACCESS
6-5/8" [168]
HEAT MANAGEMENT SYSTEMS ACCESS
10-3/8"[264]
7-1/2"[191]
33-3/16"
14-1/8"
38-1/8"
6-7/8"9-13/16"
19-7/8"26-7/8"
(843)
(359)
(968)
(175)(249)
(505)(683)33-1/4"
14-7/8"
39-3/16"
6-5/16"9-5/16"
20-3/4"27-1/16"
(845)
(377)
(995)
(160)(237)
(527)(688)
CLEAN FACE TRIM MARTINI FRONT
16-3/4"[425]
32-3/8"[822]
2-3/16"[56]
6"[152]
17-1/4"[438]
25-7/8"[657]
43-1/2"[1105]
7-3/4"[197]
41" [1041]36" [914]
32-1/4" [819]
15-1/4"[387]
33-11/16"[856]
3-1/2"[89]
7"[178]
46-1/2"[1181]
9-13/16"[249]
17-3/4"[451]
1/2" [13]30-3/4"[781]
GAS LINE ACCESS
ELECTRICALACCESS
6-5/8" [168]
HEAT MANAGEMENT SYSTEMS ACCESS
10-3/8"[264]
7-1/2"[191]
Specifications COSMO36-IFT-B
Please consult the manufacturer’s installation manual for all details and requirements before making a final
design layout decision.
COSMO 36Direct Vent Gas Fireplace
APPLIANCE LOCATION
WALL PENETRATION
MANTEL LEG/WALL PROJECTIONS (acceptable on both sides of appliance)
47-1/2"[1207]
TOP VENTONE 900 ELBOW
SEE INSTALL MANUALFOR ALCOVE INSTALLATION
TOP VENTONE 90° ELBOW
18" [457 mm] required when Passive Heat Side Discharge Kit is installed.
1/2 IN.
47-1/2"[1207]
42" [1067]
66" [1676]
15-3/4"[400]
17-1/4" [438]
Refer to Section 10.C for mantel and wall projection information in installation manual.Consider the mantel or cabinet system to be installed and comply with the necessary requirements for elevated hearth. Refer to instructions included with cabinet system.
47-1/2"
46-1/2"
[1207]
[1181]
10"10"
DO NOT PACK WITH INSULATION OR OTHER MATERIAL
• 8/17 DRAFT COPY
8-5/8"
32-3/4"
17-3/4"
42"
[219]
[832]
[451]
[1067]
NOTE: Header MUST be installed on end as shown in the diagram.
HEADER: Two 2 X 4s or Two 2 X 6s installed on end
MINIMUM FRAMING DIMENSIONS
WALL3' MAX.
6" MIN.
APPLIANCE OPENING WALLUNLIMITED
7" MIN.
APPLIANCE OPENING
Shows center of vent framing hole for top or rear venting. The center of the hole is 1" (25mm) above the center of the horizontal vent pipe.
AREA TO COMBUSTIBLES
CLEARANCE TO CEILING
31" [787]
NON-COMBUSTIBLE FLOOR
0" [0]
COMBUSTIBLE FLOORING
0" [0]
BEHIND APPLIANCE
1/2" [13]
SIDES OF APPLIANCE
1/2" [13]
FRONT OF APPLIANCE
36" [914]
31"
0"
0" 1/2"
1/2"
36"
[787]
[13]
[13]
[914]
MEASURE FROM TOP OF APPLIANCE OPENING TO CEILING
MINIMUM FIREPLACE CLEARANCES /CLEARANCES TO COMBUSTIBLES
Combustible Mantels
9 1113
14
TO CEILING
69
12
3
6 810
11
TO CEILING
69
12
3
Combustible Mantels -Passive Heat Kit Installed
Non-combustible Mantels
12" MAX.1/2" THICK WALL SHEATHING
14" MIN. BOTTOM OF MANTEL TO TOP OF APPLIANCE OPENING
NON-COMBUSTIBLE MANTEL
6" MAX.
MANTEL PROJECTIONS (or other materials above appliance)
NON-COMBUSTIBLE MANTEL PROJECTIONS (or other materials above appliance)
COSMO36-IFT-BSpecifications
Additional information can be found online at www.heatnglo.com
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
Lakeville, MN Web: heatnglo.com 952-985-6000
PRODUCT LISTING CODES
US ANSI Z21.88-2017
CAN CSA 2.33-2017
UL307B
HNG/COSMO36-IFT-B_0220