cosmo insutruments co.,ltd. - ichgmbh.com · toto molten ryobi and others… rinnai ... korea...
TRANSCRIPT
2
PlantBuilt in December, 2006
Plant has Production, Purchasing, Service, System Management departments. Also Clean Room, Training Room, Meeting Room are available.
Head OfficeHead office has the core infrastructures such as Sales, Technical, General Affair departments
COSMO INSTRUMENTS CO.,LTD
TOKYO JAPAN
Clean Room 2FAssembly Line 1FInspection Line 1F
3
Employee
Foundation
Management Principle Make great contribution to society through customers
Always respect and prioritize customer’s opinion and offer the best solution through products and services Provide the high-quality, excellent and innovative products Always try to improve own skills and abilities to reach higher level.
25/JUN/1970
72 Million Japanese Yen
Cosmo has received the award for “Best 300 Small and Medium Enterprises of shop-floor production (MONOZUKURI) in June, 2007
Award from Ministry of Economy, Trade and Industry
140 employees
Our Value
Capital Fund
4
ISO9001 Acquired in 1999Certification No#:JQA-QM3681Certified Organization:JQAScope of Certification:Head office・Plant, Domestic Sales offices, CST (USA)
ISO14001 Acquired in 2005Certification No#:JQA-EM5044Certified Organization:JQAScope of Certification:Head office、Plant
ISO/IEC 17025 Acquired in 2009Certification No#:RCL00350Certified Organization:JABScope of Certification:Dynamic Quantity(Calibration of Pressure)Cosmo Group Calibration Laboratory
Quality
Environment
Calibration
Approach to ISO Certification
6
Water-dunk method is the easiest example of Leak Testing (Air-tightness test). A bubble comes out of a part to be tested if there are leaks when dunking it in water and pressurize.
The following picture shows the part has leaks.
Parts
LeakHot
Water
What is Leak Testing???
Parts
Leak
Air
7
[No Leaks from Part]Part
( )DPS
Diaphragm
Air
Valve
Reference
CPU
Judge as OK
000AMP
[Leaks from Part]
0
Part
(DPS)
Diaphragm
Air
Valve
Reference
Leaks
CPU
Judge as NG
+100AMP
Display
Principle of Differential Pressure Method
OK NG
Display
8
Air-operated Valve
Sensor Manifold
DPS
CHG BAL DET
Pressurize both a part to be tested and a reference part (no leak at all).
Stop pressurizing and separates the part and reference.
Detect a pressure difference between the part and reference. Full scale of DPS : 1kPa
<Measurement Procedure>
Pilot Pressure
P.S
DPSTest Pressure
AV1 AV2 Stop ValveReference
Exhaust
Part
Pneumatic Circuit of Cosmo Air Leak Tester
Intelligent ⅠPneumatic Circuit
9
Multi-linked Type
LS-1441(SH16)
LS-1822ALS-1881
Standard Type
Specialized in Sealed Parts Specialized in Ultra-high Pressure (up to 16MPa)
LZ-1550
Specialized in Small Sealed Part
LS-1441(ZS)
LS-1842
Lineup of Air Leak Tester
10
Up to 8 pneumatic circuit can be connected to a monitor
High performance CPU allows quick processing
Great in maintenance
4 displays in one monitor
LS-1881 Features
12Fuel Joint High-pressure Hose
Artificial BladderElectrical Device
Pipe Joint
Water-proof Digital Camera
Back Monitor (Car)
Leak Testing Machine (1)
13Diesel Engine ASSY
Cylinder BlockTransmission
Cylinder Head
Intake ManifoldFuel Injector Water Pump
Leak Testing Machine (2)
14
DF-2800
Digital Flow MeterAir Flow Tester AF-2220 AF-2400 DF-230BA
DP GaugeDP-330
DP-330BAPressure Controller
PC-4660Micro Pressure
ElectroPneumaticRegulatorPRV-700Micro Differential
PressureTransducerPT-105A-A
Digital ManometerDM-3501
Flow Tester
Manometer・Pressure Controlling Device
Air Flow Tester Laminar Flow Mass Flow
Pressure Controlling Device
Manometer
15
Fuel Cap Test Machine Suction Joint Test Machine
Micro Pressure Electropneumatic Regulator
PRV-700
Micro Differential Pressure Transducer
PT-105A-A
Laminar Flow Tube
Mass Flow MeterDF-230BA
Flow Test Bench
Flow Tester/Meter
Calibration Machine
Pressure / Flow Testing Machine
16
TOYOTA MOTORNISSAN MOTORHONDA MOTORMAZDA MOTORMITSUBISHI MOTORSSUZUKI MOTORFUJI HEAVY INDUSTRIESDENSOKAWASAKI HEAVY INDUSTRIESAISIN SEIKI CALSONIC KANSEIJATCO
AND OTHERS…
Major Customers (1)
Automobile
17
TOSHIBANECHITACHIFUJITSUPANASONICSMCOMRONKYOCERASANYO ELECTRICCKDSEIKO EPSONTDKMITSUBISHI ELECTRIC
AND OTHERS…
Major Customers (2)
Electronic・Electric
18
ASAHI KASEINOKTOTOMOLTEN RYOBI
AND OTHERS…
RINNAINORITZPALOMAYAZAKI
AND OTHERS…
Major Customers (3)
Gas Appliance
Medical・Others
19
Meeting for specific requirementTrial testingCoordinate with machine builder
Back up serviceRepairCalibration
AdvertisementParticipation of ExhibitionTechnical training session
What Cosmo Offers
Before Service
After Service
Sale Promotion
20
Calibration
We recommend the annual regular calibration of Cosmo’s differential pressure sensor.
This could be carried out at on-site or Cosmo office.
21
Kita Kanto Sales OfficeService Center
Tohoku Sales Office
Hamamatsu
Sales Office
Nagoya Sales OfficeService Center
Osaka Sales OfficeService Center
Hiroshima Sales Office
Tokyo Sales OfficeHead Service Center
Kyushu Sales OfficeService Center
Japan Network
8 Sales Offices and 5 Service Centers
22
CHINA Indonesia Thailand UK
USA
Canada
MexicoKorea
IndiaThailand AustraliaIndonesiaChina
Taiwan
Malaysia
Singapore
UK
(Service only)Vietnam
Brazil
Overseas Network (15 nations)