Diagnostic test procedures: Output - LCD Panel test description procedure Firmware Revision Press the RESUME button five times. Most recent error code Press the RESUME button six times. Display Printhead health Press the CANCEL button and the RESUME button three times. Pages Picked: Tray 1Press the CANCEL button four times and the RESUME button three times Pages Picked: Tray 2Press the CANCEL button four times and the RESUME button four times Serial Number Press the CANCEL button four times and the RESUME button five times Diagnostic test procedures: Output - printout test description procedure Demo Page Press the RESUME button once. Demo Page - Double-sided Press the CANCEL button three times and the RESUME button one time. Pen Calibration Press the RESUME button three times. Self Diagnostic Page Press the CANCEL button one time. Paper path calibration data Press the CANCEL button one time and the RESUME button one time. Technical Diagnostic Page Press the CANCEL button one time and the RESUME button five times. Spot Sensor Check Press the CANCEL button three times and the RESUME button four times. Skew Test - Econofast mode - A size - Tray 1 Press the CANCEL button six times and the RESUME button seven times. Skew Test - Econofast mode - A size - Tray 2 Press the CANCEL button six times and the RESUME button eight times. Skew Test - Econofast mode - B size - Tray 1 Press the CANCEL button six times and the RESUME button nine times. Skew Test - Econofast mode - B size - Tray 2 Press the CANCEL button seven times. Skew Test - Normal mode - A size - Tray 1 Press the CANCEL button seven times and the RESUME button one time. Skew Test - Normal mode - A size - Tray 2 Press the CANCEL button seven times and the RESUME button two times. Nozzle Pattern Press the CANCEL button eight times and the RESUME button four times. EDD diagnostic Information Press the CANCEL button nine times and the RESUME button two times

Upload: dean-stacey

Post on 30-Apr-2017

218 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: CP1700 Diagnostic Test Procedures

Diagnostic test procedures: Output - LCD Panel test description procedure

Firmware Revision Press the RESUME button five times. Most recent error code Press the RESUME button six times. Display Printhead health

Press the CANCEL button and the RESUME button three times.

Pages Picked: Tray 1 Press the CANCEL button four times and the RESUME button three times

Pages Picked: Tray 2 Press the CANCEL button four times and the RESUME button four times

Serial Number Press the CANCEL button four times and the RESUME button five times

Diagnostic test procedures: Output - printout test description procedure

Demo Page Press the RESUME button once. Demo Page - Double-sided Press the CANCEL button three times and the RESUME

button one time. Pen Calibration Press the RESUME button three times. Self Diagnostic Page Press the CANCEL button one time. Paper path calibration data Press the CANCEL button one time and the RESUME

button one time. Technical Diagnostic Page Press the CANCEL button one time and the RESUME

button five times. Spot Sensor Check Press the CANCEL button three times and the RESUME

button four times. Skew Test - Econofast mode - A size - Tray 1

Press the CANCEL button six times and the RESUME button seven times.

Skew Test - Econofast mode - A size - Tray 2

Press the CANCEL button six times and the RESUME button eight times.

Skew Test - Econofast mode - B size - Tray 1

Press the CANCEL button six times and the RESUME button nine times.

Skew Test - Econofast mode - B size - Tray 2

Press the CANCEL button seven times.

Skew Test - Normal mode - A size - Tray 1

Press the CANCEL button seven times and the RESUME button one time.

Skew Test - Normal mode - A size - Tray 2

Press the CANCEL button seven times and the RESUME button two times.

Nozzle Pattern Press the CANCEL button eight times and the RESUME button four times.

EDD diagnostic Information Press the CANCEL button nine times and the RESUME button two times

Page 2: CP1700 Diagnostic Test Procedures

Diagnostic test procedures: No Output test description procedure

Continuous H pattern Press the RESUME button 8 times. Continuous color H pattern Press the CANCEL button one time and the RESUME button three

times. Pen recovery level 1 Press the CANCEL button two times. Pen recovery level 2 Press the CANCEL button two times and the RESUME button one

time. Pen recovery level 3 Press the CANCEL button two times and the RESUME button two

times. Purge RIDS tubes Press the CANCEL button two times and the RESUME button five

times. Disable Purge RIDS Press the CANCEL button two times and the RESUME button

eight times. Continuous Pick: Main Press the CANCEL button four times and the RESUME button six

times. Continuous Pick: 2nd Press the CANCEL button four times and the RESUME button

seven times. Continuous Pick: Main Duplex

Press the CANCEL button four times and the RESUME button eight times.

Continuous Pick: 2nd Duplex

Press the CANCEL button four times and the RESUME button nine times.

LIO test Press the CANCEL button eight times and the RESUME button eight times.