cpko tsb indiagoodluckmkt.com/pdf/industrial_pump/cpk_o/cpko_data.pdf · standardized chemical...

8
CPKO Page | 1 Product Data 2737.1 G3 Technical Specification Standardized chemical pumps 1. Design Horizontal, radially split volute casing pump in back pull-out design, with semi open Impeller, single- entry, single-stage; to EN 22 858/ISO 2858/ISO 5199; Complemented by pumps of DN 25. 2. Application Handling aggressive, polymerizing media or media liable to form lumps as well as gas-containing liquids in the chemical and petrochemical industries. 3. Designation Type series --------------------- Open impeller ------------------ Material of wetted parts ------ Discharge nozzle DN --------- Nominal impeller dia. in mm 4. Operating data Parameters Flow, Q 100 m³/h Head, H 85 m Nom. Sizes, DN DN 25 to DN 65 Pressure, Bar 16 Bar / 25 Bar Temperature limits -70 to 300 Deg C Chemical standard pumps According to ISO 2858 / DIN 24 256 and ISO 5199 With Semi-open impeller

Upload: others

Post on 23-Jul-2020

15 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: CPKO TSB Indiagoodluckmkt.com/pdf/industrial_pump/CPK_O/CPKO_DATA.pdf · Standardized chemical pumps 1. Design Horizontal, radially split volute casing pump in back pull-out design,

    CPKO 

Page | 1  

Product Data 2737.1 G3

Technical Specification Standardized chemical pumps

1. Design

Horizontal, radially split volute casing pump in back pull-out design, with semi open Impeller, single-entry, single-stage; to EN 22 858/ISO 2858/ISO 5199; Complemented by pumps of DN 25.

2. Application

Handling aggressive, polymerizing media or media liable to form lumps as well as gas-containing liquids in the chemical and petrochemical industries.

3. Designation

Type series --------------------- Open impeller ------------------ Material of wetted parts ------ Discharge nozzle DN --------- Nominal impeller dia. in mm

4. Operating data

Parameters

Flow, Q 100 m³/h

Head, H 85 m Nom. Sizes, DN DN 25 to DN 65 Pressure, Bar 16 Bar / 25 Bar Temperature limits -70 to 300 Deg C

Chemical standard pumps According to ISO 2858 / DIN 24 256 and ISO 5199

With Semi-open impeller

Page 2: CPKO TSB Indiagoodluckmkt.com/pdf/industrial_pump/CPK_O/CPKO_DATA.pdf · Standardized chemical pumps 1. Design Horizontal, radially split volute casing pump in back pull-out design,

    CPKO 

Page | 2  

Family Curves

Below are the family curves for nominal speed at 50Hz of supply frequency. Initial selection of the pump is to be done from these curves. If the required operating speed is different from the nominal speed, then the operating parameters should be converted to the nominal speed and then the selection is to be done.

Highlighted 14 Models will be available from KSB India.

Page 3: CPKO TSB Indiagoodluckmkt.com/pdf/industrial_pump/CPK_O/CPKO_DATA.pdf · Standardized chemical pumps 1. Design Horizontal, radially split volute casing pump in back pull-out design,

    CPKO 

Page | 3  

5. Pressure and temperature limits

Refer to CPK Type series booklet for details. 6. Material of Construction

  Parts  Material GC  Material E, EC  Material C* 

1  VOLUTE CASING  CI FG260 WCB CF8M 

2  CASING COVER  CI FG260 WCB CF8M 

3  ST. BOX PK. RING (PKG)  CI FG260 CI FG260 CF8M 

4  LANTERN RING (PKG)  CI FG260 CI FG260 CF8M 5  NECK RING (PKG)  CI FG260 CI FG260 TYPE 316 

6  ST. BOX GLAND (PKG)  CI FG260 CI FG260 CF8M 

7  SHAFT PROT SLEEVE (PKG)  TYPE 316 TYPE 410 TYPE 316 8  IMPELLER  CF8M WCB, CF8M CF8M 

9  IMPELLER NUT  CF8M CF8M  CF8M 

10  WEAR PLATE  CI FG260 WCB, CF8M  CF8M 

11  SHAFT         45C8, Type 410 45C8, Type 410  45C8, 410, 1.4462 

* Models 25-160, 25-200 & 65-160 are not available in GC variant.

Notes: 1) When Vu>40 m/sec. or operating temp. 250°C to 300°C use CF8M for Impeller. 2) Fasteners of grade B7/2H should be offered if operating temperature > 250°C. 3) Shaft is given in 45C8 for operating temperature in the range -10°C to +250°C. For

temperature > 250°C; shaft material is A 276 Type 410. For temperature -10 to -40°C; shaft material is 1.4462.

4) Bearing bracket lantern is given in WCB if operating temperature > 200 °C & for hot water above 180°C. Bearing bracket lantern in CF8M if operating temperature < -30°C.

7. Flanges:

Refer CPK type series booklet for details.

8. Bearing Bracket:

The bearing bracket houses bearings as follows,

Page 4: CPKO TSB Indiagoodluckmkt.com/pdf/industrial_pump/CPK_O/CPKO_DATA.pdf · Standardized chemical pumps 1. Design Horizontal, radially split volute casing pump in back pull-out design,

    CPKO 

Page | 4  

9. General Assembly Drawings with Lists of Components

Page 5: CPKO TSB Indiagoodluckmkt.com/pdf/industrial_pump/CPK_O/CPKO_DATA.pdf · Standardized chemical pumps 1. Design Horizontal, radially split volute casing pump in back pull-out design,

    CPKO 

Page | 5  

Page 6: CPKO TSB Indiagoodluckmkt.com/pdf/industrial_pump/CPK_O/CPKO_DATA.pdf · Standardized chemical pumps 1. Design Horizontal, radially split volute casing pump in back pull-out design,

    CPKO 

Page | 6  

10. Pump Dimensions:

Page 7: CPKO TSB Indiagoodluckmkt.com/pdf/industrial_pump/CPK_O/CPKO_DATA.pdf · Standardized chemical pumps 1. Design Horizontal, radially split volute casing pump in back pull-out design,

    CPKO 

Page | 7  

11. Auxiliary connections on Pump:

* For casing drain threaded and seal welded, termination of drain piping by DN 15 ANSI flanges for P 25/62.

Page 8: CPKO TSB Indiagoodluckmkt.com/pdf/industrial_pump/CPK_O/CPKO_DATA.pdf · Standardized chemical pumps 1. Design Horizontal, radially split volute casing pump in back pull-out design,

    CPKO 

Page | 8  

12. Pump weights:

Pump Sizes CPKO GC 

, Kg CPKO C / E, EC 

, Kg 

25‐160   32  39 

25‐200   38  43 

32‐125   34  40 

32‐160   35  41 

32‐200   42  51 

40‐160   37  43 

40‐200   43  51 

50‐160   40  46 

50‐200  47  52 

32‐250   79  88 

40‐250   79  88 

50‐250   79  89 

65‐160   62  77 

65‐200  69  84 

For more details, refer Type series booklet of CPK.