  • Cray XT and Cray XEy ySystem Overview

    Customer Documentation and Training

  • Overview Topics

    • System Overview– Cabinets, Chassis, and Blades– Compute and Service Nodes– Components of a Node

    Opteron ProcessorOpteron ProcessorSeaStar ASIC • Portals API DesignGemini ASIC

    • System Networks• Interconnection Topologies

    10/18/2010 2Cray Private

  • Cray XT System

    10/18/2010 3Cray Private

  • System Overview

    GigE

    X

    YZ

    10 GigE

    GigE

    Fibre

    SMW

    RAIDSubsystem

    Channels

    Compute node

    Login nodeg

    Network node

    Boot /Syslog/Database nodes

    I/O and Metadata nodes10/18/2010 4Cray Private

  • Cabinet

    – The cabinet contains three chassis, a blower for cooling, a power distribution unit (PDU), a control system (CRMS), and the compute and service blades (modules)

    – All components of the system are air cooled

    A blower in the bottom of the cabinet cools the blades within the cabinet• Other rack-mounted devices

    within the cabinet have theirwithin the cabinet have their own internal fans for cooling

    – The PDU is located behind the blower in the back of the cabinet

    10/18/2010 5Cray Private

  • Liquid Cooled CabinetsHeat exchanger(LC cabinets only)

    Heat exchanger(XT5-HE LC only)

    Cage 2Cage 248Vdc flexiblebuses

    Cage 1 Cage 1

    0 1 2 3 4 5 6 7

    Cage 0

    Cage inletair temp

    Heat exchanger(LC cabinets only)

    Cage 0backplaneassembly

    Cage VRMs

    Cage IDcontroller Interconnect

    network cableconnection

    Blower speedcontroller (VFD)

    Blower

    air tempsensor(slot 3 rail)

    Airflowconditioner

    Heat exchanger(XT5-HE LC only)

    L1 controller

    48Vdc shelf 3

    48Vdc shelf 2

    48Vdc shelf 1

    PDUo eline filter

    XDP temperature& humidity sensor(behind perforatedpanel in someXT5-HE LCcabinets)

    XDP interfaceboard (behindperforated panel,XT5-HE LC only)

    10/18/2010 6Cray Private

  • Blades

    • The system contains two types of blades:– Compute blades

    4 SeaStar or 2 Gemini ASICs4 nodes

    – Service blades– Service bladesSIO (XT systems)• 4 SeaStar ASICs• 2 nodes• One dual-slot PCI-X or PCIe riser assemblies per node XIO (XE systems)XIO (XE systems)• 2 Gemini ASICs• 4 nodes

    O i l l t PCI i d ( t th b t d )• One single slot PCIe riser per node (except on the boot node)

    10/18/2010 7Cray Private

  • PCI Cards

    • Cray supports the following types of PCIe cards:– Gigabit Ethernet– 10Gigabit Ethernet– Fibre Channel (FC2, FC4, and FC8)

    I fi iB d– InfiniBand

    10/18/2010 8Cray Private

  • Node Components

    – Opteron processorSingle-, dual-, quad-, six-, eight-, twelve-core versions

    N d– Node memory2- to 8-GB of DDR1 memory in Cray XT3 compute nodes2- to 8-GB of DDR1 memory in Cray XT service (SIO) nodes2 to 8 GB of DDR1 memory in Cray XT service (SIO) nodes4- to 16-GB of DDR2 memory in Cray XT4 compute nodes4- to 32-GB of DDR2 memory in Cray XT5 compute nodes8 t 64 GB f DDR3 i C XT6 t d8- to 64-GB of DDR3 memory in Cray XT6 compute nodes8- to 64-GB of DDR3 memory in Cray XE6 compute nodes8- to 16-GB of DDR2 memory in Cray XE6 service (XIO) nodesy y ( )

    – SeaStar or Gemini ASIC

    10/18/2010 9Cray Private

  • Cray XT4 Compute Blade

    Node memory

    Node VRMNode 1

    N d 2

    Node 0

    Node 2

    Node 3

    SeaStar

    Node 3

    L0 controller

    48Vdc to 12Vdc VRMs

    L0 controller

    10/18/2010 10Cray Private

  • XT4 Node Block Diagram

    Opteron

    M s

    lots

    processorX86-64

    4 D

    IMM

    HyperTransportLink

    SeaStarHigh-speednetwork (HSN)(interconnect)( )

    L0 controller

    10/18/2010 11Cray Private

  • SIO Service Blade

    PCI cardPCI card

    Node 3

    Node 01

    23

    PCI riser0

    PCI riser(PCI-X or PCIe)

    10/18/2010 12Cray Private

  • SeaStar ASIC

    – Direct HyperTransport connection to Opteron– The DMA engine transfers data between the host

    d th t kmemory and the networkSeparate read and write sides in the DMA engineThe Opteron does not directly load/store to network p yOn the receive side a set of content addressable memory (CAM) locations are used to route incoming messages• There are 256 CAM entries• There are 256 CAM entries

    – Designed for Sandia Portals API

    10/18/2010 13Cray Private

  • SeaStar Diagram

    MemoryDDR-

    SDRAMinterface

    Northbridge

    Core

    interface

    HyperTransportInterface

    HyperTransportInterface

    SeaStarDMA

    engineHyper

    TransportRx

    To PCI-X onService blades

    Memory

    engine TransportRou

    x

    y

    SSI PPU

    Memoryter

    y

    z

    L0 controller

    SSI PPUr

    10/18/2010 14Cray Private

  • Node Connection Bandwidths

    +Y

    Opteroncore(s)

    ory

    GB

    /s HyperTransport

    +Y

    Mem

    o

    HyperTransportCray XT3 6.4 GB/s bidirectional

    2.17 GB/s sustainedCray XT4 8.0 GB/s bidirectional

    9.6

    G +Z

    MemoryCray XT3 DDR1 6.4 GB/s (400 MHz DIMMs)

    5.7 GB/s sustained51.6 ns latency - measured

    Cray XT4 DDR2 10.4 GB/s (667 MHz DIMMs)8 5 GB/s sustained

    9.6 GB/s SeaStar 9.6 GB/s-X +X8.5 GB/s sustained

    50 ns latency - measuredCray XT4 DDR2 12.8 GB/s (800 MHz DIMMs)

    Cray XT5 DDR2 10.4 GB/s (667 MHz DIMMs)Cray XT5 DDR2 12.8 GB/s (800 MHz DIMMs)G

    B/s

    High Speed Network9.6 GB/s bidirectional6.5 GB/s sustained

    Cray XT5 DDR2 12.8 GB/s (800 MHz DIMMs)

    9.6

    -Y

    -Z

    10/18/2010 15Cray Private

  • Portals API Design

    – Designed to message among thousands of nodesPerformance is critical only in terms of scalabilityS i d b h l li ti i ll d tSuccess is measured by how large an application is allowed to scale, not by a 2-node ping-pong time

    – Designed to avoid scalability limitationsIs network independentBypasses OS – no memory copies into or out of the kernel; few interruptsinterruptsBypasses application – does not require activity by the application to ensure progressReliable ordered delivery of messages between two nodesReliable, ordered delivery of messages between two nodes

    10/18/2010 16Cray Private

  • Portals API Design

    – Receiver (target) managed – no reserved memory for thousands of potential senders

    I ti l li it ti i t bli h d ithIs connectionless; no explicit connection is established with other processes in the application• When connected, maintains a minimum amount of stateThe target process determines how to respond to the incoming message• The target node can choose to accept or ignore a message

    from any node• Destination of any message is not an address

    – Instead “Match bits” enable the receiver to place itInstead Match bits enable the receiver to place itUnexpected messages are handled by the unexpected message queueAll buffers are in user spaceAll buffers are in user space

    10/18/2010 17Cray Private

  • X6 Compute Blade with Gemini

    Node 3

    N d 2 Gemini 1Node 2 Gemini 1

    Node 1

    Gemini 0

    Node 0

    Gemini 0

    10/18/2010 18Cray Private

  • XE6 Node Block Diagram

    slot

    s

    OpteronOpteron

    slot

    s

    4 D

    IMM

    sprocessorX86-64

    processorX86-64

    4 D

    IMM

    s

    HyperTransportLinks

    SeaStar (XT)Gemini (XE)

    High-speednetwork (HSN)(interconnect)( )

    L0 controller

    10/18/2010 19Cray Private

  • XIO Service Blades

    • Four nodes; each node contains:– One AMD Opteron processor with up to 16 GB of DDR2

    memoryProcessor is a six-core Opteron

    – A connection to a Gemini ASICA connection to a Gemini ASIC– Voltage regulating modules (VRMs)

    • L0 controllerL0 controller• Gemini mezzanine card

    – Contains two Gemini ASICsContains two Gemini ASICs• Four PCIe risers

    – One riser per nodep

    10/18/2010 20Cray Private

  • XIO Blade

    Node 3node 3 connects to the lower mezzanine

    Node 2 Gemini 1

    Node 1node 1 connects to the lower

    Node 0

    Gemini 0mezzanine

    10/18/2010 21Cray Private

  • XIO Riser Configuration

    PCIe G2Inner

    DDR2memory

    x16 HyperTransport

    Upper bay

    Opteronnode 3

    PCIe G2bridge

    Innermezzanine

    DDR2memory

    x16 HyperTransport

    Gemini

    HyperTransport

    HyperTransport

    75 Watt slot

    225 Watt slot

    Opteronnode 2

    PCIe G2bridge

    Outer mezzanine

    DDR2memory

    x16 HyperTransport

    HyperTransport

    Opteronnode 1

    PCIe G2bridge

    Innermezzanine

    memory

    x16 HyperTransport

    HyperTransportnode 1

    OpteronPCIe G2Outer

    DDR2memory

    x16 HyperTransport

    GeminiHyperTransport

    75 Watt slot

    225 Watt slot

    Opteronnode 0bridgemezzanine

    Lower bay10/18/2010 22Cray Private

  • XIO Boot Node Configuration

    PCIe G2Inner

    DDR2memory

    x16 HyperTransport

    Upper bay

    Opteronnode 3

    PCIe G2bridge

    Innermezzanine

    DDR2memory

    x16 HyperTransport

    Gemini

    HyperTransport

    HyperTransport

    Opteronnode 2

    PCIe G2bridge

    Outer mezzanine

    DDR2memory

    x16 HyperTransport

    HyperTransport

    Opteronnode 1

    PCIe G2bridge

    Innermezzanine

    memory

    x16 HyperTransport

    HyperTransportnode 1

    OpteronPCIe G2Outer boot

    DDR2memory

    x8 HyperTransport

    GeminiHyperTransport

    Opteronnode 0bridgemezzanine

    Lower bay10/18/2010 23Cray Private

  • Opteron Processors

    CPU

    L1 I cache L1 D cache

    L2 cache

    CPU

    L1 caches L1 caches

    L2 cache

    CPU CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2L2 cache

    System request queue

    CrossbarMemory

    System request queue

    CrossbarMemory

    System request queue

    Crossbar

    L3 cache

    Controller

    DDR

    Controller

    DDR

    CrossbarMemory

    Controller

    DDR

    Hyper-TransportLinks

    Hyper-TransportLinks Hyper-Transport

    Links

    AMD Opteron single-core processorCray XT3 SystemSocket 940: DDR1 buffered DIMMs

    AMD Opteron quad-core processorCray XT4 System Socket AM2: DDR2 unbuffered DIMMs

    AMD Opteron dual-core processorCray XT3 SystemSocket 940: DDR1 buffered DIMMs

    and 3 HyperTransports and one HyperTransportCray XT5 SystemSocket F: DDR2 registered (buffered)

    DIMMsand 3 HyperTransports

    and 3 HyperTransportsCray XT4 SystemSocket AM2: DDR2 unbuffered DIMMs

    and one HyperTransport

    AMD Opteron hex-coreprocessor

    10/18/2010 24Cray Private

  • Opteron Processors

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    CPU

    L1 s

    L2

    System request queue

    Crossbar

    L3 cache

    L2 L2

    System request queue

    Crossbar

    L3 cache

    System request queue

    Crossbar

    L3 cache

    CrossbarMemory

    Controller

    DDR

    Hyper-TransportLinks

    MemoryController

    DDR

    Hyper-TransportLinks

    MemoryController

    DDR

    Hyper-TransportLinks

    AMD Opteron six-core processorCray XT5 SystemSocket F: DDR2 unbuffered DIMMs

    AMD Opteron twelve-core processorDual-die socket

    (for an eight-core socket remove twoand 3 HyperTransportsL3 Cache: 6 MB

    (for an eight core socket remove twoCPUs from each side)

    Cray XT6 and Cray XE6 SystemsSocket G34: DDR3 unbuffered DIMMs

    and 4 HyperTransportsL3 cache: each die has 6 MBs, 12 MB per socket

    10/18/2010 25Cray Private

  • Gemini

    • Gemini is designed to pass data to and from the network with less control

    G i i i it d f SMP– Gemini is suited for SMP– Gemini allows for adaptive routing

    Hardware support for PGAS languages– Hardware support for PGAS languagesRemote memory address translations, as with Cray X2 systems

    – Atomic memory operationsy p• The Gemini chip uses HyperTransport version 3

    10/18/2010 26Cray Private

  • Gemini Block Diagram

    Opteron Opteron Opteron Opteron

    Node 0 Node 1

    HyperTransportand NIC 0

    HyperTransportand NIC 1

    Router

    L0 processor

    10/18/2010 27Cray Private

  • Terminology

    • BTE – Block Transfer Engine• DMAPP – Distributed Memory Application• FMA – Fast Memory Access• GHAL – Generic Hardware Abstraction Layery• GNI – Generic Network Interface• PGAS – Partitioned Global Address SpacePGAS Partitioned Global Address Space

    – Programming language extensions such as Unified Parallel C (UPC) and Co-Array Fortran (CAF)

    10/18/2010 28Cray Private

  • Performance and Resiliency Features

    • Automatic link-level and HT3 retries– HT3 supports an improved CRC

    • Congestion feedback to enable routing around network bottlenecks

    P k t d d i i b ff– Packets are reordered in receive bufferSeparate completion notification when all are stored

    • Automatic link failure handling with software help• Automatic link failure handling with software help– To route around a failed link, system traffic must be

    quiesced to prevent deadlock and preserve orderingThis feature is also used to support hot blade swap

    • Router errors are detected and reported at the point of error

    10/18/2010 29Cray Private

  • Gemini ASIC Diagram

    HT3 HT3

    NIC 0 NIC 1

    Tile 0, coordinate 0,0 Tile 7, coordinate 0,7

    Netlink block

    48-port YARC router

    Tile 47, coordinate 5,7

    10/18/2010 30Cray Private

  • Node Types

    – Compute nodesNo user loginO l f ti f ll l li tiOnly for execution of parallel applications Diskless - no permanent storageCNL operating system• Linux symmetrical multi-processing (SMP)• Supports OpenMP programming model• apinit part of ALPS (Application Level Placement Scheduler)• apinit part of ALPS (Application Level Placement Scheduler)

    – Service NodesProvide services based on hardware/software configurationgNode names: boot node, SDB, syslog, login, I/O, and network nodesRun Linux operating system - SLESRun Linux operating system SLES

    10/18/2010 31Cray Private

  • Service Nodes

    – Boot nodeFirst node bootedH it t fil tHas its own root file systemExports the “shared root” file system to the other service nodes

    – System database (SDB) nodey ( )Stores system configuration information and system stateImplemented with MySQL Pro

    – syslog nodeCollects syslog data from other service nodes

    – Login nodes– Login nodesProvide users with a familiar Linux environmentEdit, compile, submit, and monitor interactive or batch jobs• PBS Pro is the standard batch system

    10/18/2010 32Cray Private

  • Service Nodes

    – I/O nodesAttach to RAID storage devicesP f t DMA I/O th h th HSNPerform remote DMA I/O through the HSNFunction as a metadata server (MDS) and object storage servers (OSSs) for Lustre file systems

    – Network nodes10 Gigabit Ethernet (10GbE) adapterConnect to other file serversConnect to other file servers

    10/18/2010 33Cray Private

  • Service Node Software Components

    – ALPS - Application Level Placement SchedulerApplication placement, launch and management for CNLI l d l d d li tIncludes several daemons and client processes

    – RCA – Resiliency Communication AgentPart of the kernel, on all nodesPart of the kernel, on all nodesSends a heartbeat message to the SMW (CRMS/HSS/CMS)Detects and responds to failing application launchers

    10/18/2010 34Cray Private

  • System Networks

    • The High-speed Network (HSN) or interconnect network– Connects the service and compute nodes

    The preferred topology is a folded torus• A torus is a circle• Folding enables the use of the shortest cables possible toFolding enables the use of the shortest cables possible to

    connect all nodes within a dimension • Depending on the class, the topology may be a meshThe class of the system governs the configurationThe class of the system governs the configuration

    – Applications move data across the HSN• The Hardware Supervisory System (HSS) networkThe Hardware Supervisory System (HSS) network

    – Monitors and controls the system– Ethernet network with the System Management y g

    Workstation (SMW) is at the top of the network

    10/18/2010 35Cray Private

  • Interconnect Network Topology Classes

    • Configurations are based on topology classes:– Class 0 contains 1 to 9 chassis (1 to 3 cabinets)

    1 row– Class 1 contains 4 to 16 cabinets

    1 row1 row– Class 2 contains 16 to 48 cabinets

    2 equal length rows– Class 3 contains 48 to 320 cabinets

    Three rows of equal lengthA h i di i• A mesh in one or more dimensions

    Even number of 4 or more equal length rows• Torus in all dimensions

    10/18/2010 36Cray Private

  • A Single-chassis Configuration

    • The basic building block is a single chassis– A chassis is 1 x 4 x 8– A chassis is 1 x 4 x 8

    Dimensions are: X x Y x Z– Each node on a blade is

    connected in the Y dimensionconnected in the Y dimension (mezzanine)

    – Each node in a chassis is connected in the Z dimension ad

    e

    (backplane)– All X-dimension connections

    are cables

    ars

    in a

    bla

    y

    4 S

    eaS

    tax

    y

    z

    10/18/2010 37Cray Private

  • Network Connectors

    10/18/2010 38Cray Private

  • Class 0 Topology

    10/18/2010 39Cray Private

  • Class 0 Cable Drawing, 3 Cabinets

    ZY

    X

    10/18/2010 40Cray Private

  • Class 1 Topology

    10/18/2010 41Cray Private

  • Class 1 Cable Drawing, 4 Cabinets

    10/18/2010 42Cray Private

  • Class 2 Topology

    Y

    X Z

    10/18/2010 43Cray Private

  • Class 2 Cable Drawing, 16 Cabinets

    X

    Z

    Y

    10/18/2010 44Cray Private

  • Class 3 Topology

    Z

    X

    Z

    Y

    10/18/2010 45Cray Private

  • HSN Cabling Photo

    10/18/2010 46Cray Private

  • Cray XT5m

    • Cray XT5m topology• 1 to 18 chassis,1 to 6

    cabinetscabinets• All cabinets are in a single

    row • The system scales in units ofThe system scales in units of

    chassis• 2D torus topology (y and z)

    • (Y x 4) x 8 topology(Y x 4) x 8 topology • Y is the number of

    populated chassis in the systemy

    10/18/2010 47Cray Private

  • Identifying Components

    • System components are labeled according to physical ID (HSS Identification), node ID, IP address, or class

    Component Format DescriptionSystem s0, all All components attached to the SMW.Cabinet cX-Y Cabinet number and row; this is the L1 host name.;

    Cage cX-Yc# Physical cage in cabinet: 0, 1, 2. Cages are numbered from bottom to top.

    Bl d l t X Y # # Physical blade slot in cage:0 – 7, numbered fromBlade or slot cX-Yc#s# Physical blade slot in cage:0 7, numbered from left to right; this is the L0 hosts name.

    Node cX-Yc#s#n# Opteron Chip on a blade: 0 - 3 for compute blades, 0 and 3 for SIO bladesSeaStar ASIC cX-Yc#s#s# Cray SeaStar ASIC on a blade: 0 – 3Gemini ASIC cX-Yc#s#g# Cray Gemini ASIC on a blade: 0 – 1

    X Y # # #l# f S S S CLink cX-Yc#s#s#l#cX-Yc#s#g#l#Link port of a SeaStar ASIC: 0 – 5Link port of a Gemini ASIC: 0 - 57

    10/18/2010 48Cray Private

  • Node ID (NID)

    • The Node ID is a unique hexadecimal or decimal number that identifies each CLE node

    Th NID fl t th d l ti i th t k– The NID reflects the node location in the networkIn a SeaStar based system, the NIDs are assigned on 128-number boundaries for each cabinet In a Gemini based system, NIDs are sequential

    – NID format is nidnnnnn (decimal) when it refers to a hostname of a node for example: nid00003hostname of a node, for example: nid00003

    10/18/2010 49Cray Private

  • Cabinet 0 NID Numbering Example6,

    67

    0, 7

    1

    4, 7

    5

    8, 7

    9

    2, 8

    3

    6, 8

    7

    0, 9

    1

    4, 9

    5

    4, 9

    5

    2, 9

    3

    0, 9

    1

    8, 8

    9

    6, 8

    7

    4, 8

    5

    2, 8

    3

    0, 8

    1

    Cray XT (SeaStar based) system Cray XE (Gemini based) system 64

    , 65,

    66

    68, 6

    9, 7

    0

    72, 7

    3, 7

    4

    76, 7

    7, 7

    8

    80, 8

    1, 8

    2

    84, 8

    5, 8

    6

    88, 8

    9, 9

    0

    92, 9

    3, 9

    4

    64, 6

    5, 9

    4

    66, 6

    7, 9

    2

    68, 6

    9, 9

    0

    70, 7

    1, 8

    8

    72, 7

    3, 8

    6

    74, 7

    5, 8

    4

    76, 7

    7, 8

    2

    78, 7

    9, 8

    0

    3, 3

    4, 3

    5

    7, 3

    8, 3

    9

    1, 4

    2, 4

    3

    5, 4

    6, 4

    7

    9, 5

    0, 5

    1

    3, 5

    4, 5

    5

    7, 5

    8, 5

    9

    1, 6

    2, 6

    3

    3, 6

    2, 6

    3

    5, 6

    0, 6

    1

    7, 5

    8, 5

    9

    9, 5

    6, 5

    7

    5, 4

    0, 4

    1

    3, 4

    2, 4

    3

    5, 5

    0, 5

    1

    7, 4

    8, 4

    9

    3 7 1 15 19 23 27 31

    32, 3

    3

    36, 3

    7

    40, 4

    1

    44, 4

    5

    48, 4

    9

    52, 5

    3

    56, 5

    7

    60, 6

    1

    31 29 27 25 23 21 19 17

    32, 3

    3

    34, 3

    5

    36, 3

    7

    38, 3

    9

    54, 5

    5

    52, 5

    3

    44, 4

    5

    46, 4

    7

    0, 1

    , 2, 3

    4, 5

    , 6, 7

    8, 9

    , 10,

    1

    2, 1

    3, 1

    4,

    6, 1

    7, 1

    8,

    0, 2

    1, 2

    2,

    4, 2

    5, 2

    6,

    8, 2

    9, 2

    0,

    0, 1

    , 30,

    3

    2, 3

    , 28,

    2

    4, 5

    , 26,

    2

    6, 7

    , 24,

    2

    8, 9

    , 22,

    2

    0, 1

    1, 2

    0,

    2, 1

    3, 1

    8,

    4, 1

    5, 1

    6,

    8 12 16 20 24 28 0 2 4 6 8 10 12 14

    10/18/2010 50Cray Private

  • Cray System

    10/18/2010 Cray Private 51

  • External Services for Cray Systems

    – Implementation of services external to the Cray XT and Cray XE systems to address customer requirements

    M fl iblMore flexible user accessMore options for data management, data protectionLeverage commodity components in customer-specific implementationsProvides faster access to new devices and technologies Repeatable solutions that remain open to custom configurationRepeatable solutions that remain open to custom configurationEach solution can be used, scaled, and configured independently

    esFS esLogin esDM

    10/18/2010 52Cray Private

  • Specifically

    – esFSProvides globally shared data between multiple systems

    C t d th• Cray systems and othersProvides access to other file systemsData Virtualization Service (DVS) is used to project Panasas or StorNext to the compute nodes

    – esLoginLess dependence on a single Cray system for data access andLess dependence on a single Cray system for data access and compilesAn enhanced user environment

    l d h• larger memory, swap space, and more horsepower• Increased availability of data and system services to users

    – esDMesDMMore options for data management and data protection

    10/18/2010 53Cray Private

  • esLogin

    Cray XE System

    Service/MOM nodeService/MOM node

    NIC

    XE | AP Clientside commands

    XE ProgrammingEnvironment

    Batch Client Software

    Modules

    NIC NIC NIC

    MS

    10/18/2010 Cray Private 54

    esMS User network Other services