cross section a - a1 · 2016 scale: 1/8" = 1'-0" roof 1: 274 s.f. x .08 = 22 cu ft...

5
Roof 1: 274 sf Roof 2: 290 sf 17'-0" 14'-2" 16'-2" 20'-6" O.H.L. 99 98.5 98 97 97.5 96.5 99 98 97 96.5 98.5 97.5 A A1 util pole guy wire exst. wisteria exst wisteria s i d e w a l k overflow Exst French drain below grade Proposed river cobble swale to carry surface water toward rain garden Extend buried pipes from sump pump & French drain to empty into rain garden Rain garden -- 150 sq ft -- see planting detail River cobble at overflow T H I R D S T R E E T S O U T H Berm around lower side of rain garden 26'-0" (+/-) 6'-0" (+/-) asphalt driveway Additional conservation planting area River cobble where pipe daylights into rain garden Roofs drain directly onto ground below. There is currently a French drain underground along the perimeter of the building. 0 5 10 FT Outline of previous house addition to be shown with stone band (not part of Arlington StormwaterWise project) Ball-Sellers House Museum 5620 3rd St. South Arlington, VA 22204 Plan View & Stormwater Calculations Arlington County StormwaterWise Program Edward Colahan Landscape Design 3276 Valley Dr. Alexandria, VA 22302 202.255.2585 [email protected] Date: July 26, 2016 Scale: 1/8" = 1'-0" Roof 1: 274 s.f. x .08 = 22 cu ft Roof 2: 290 s.f. x .08 = 23 cu ft Total volume for 1" storm event: 45 cu ft Infiltration Test Results: 4.7 in/hr. Stormwater calculations for 1" storm event: 6" ponding area: 150 s.f. x .5 = 75 cu ft 6" bioretention soil: 150 s.f. x .5 x .25 = 18.75 cu ft Total treatment volume: 93.75 cu ft (or roughly 2" storm event) Rain garden treatment calculations:

Upload: others

Post on 21-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cross Section A - A1 · 2016 Scale: 1/8" = 1'-0" Roof 1: 274 s.f. x .08 = 22 cu ft Roof 2: 290 s.f. x .08 = 23 cu ft ... Ls CvCv Cv Cv CvCv Cv Cv Cv Cv CvCv Ls Ls LsLs Ls Ah Ah Ah

Roof 1: 274 sf Roof 2: 290 sf

17'-0"

14'-2

"

16'-2

"

20'-6"

O.H.L.

99

98.5

9897

97.5

96.5

99

989796.5

98.597.5

A A1

util pole

guy wire

exst. wisteria

exst wisteria

s i d e w a l k

over

flow

Exst French drain below grade

Proposed river cobble swale to carry surface water toward rain garden

Extend buried pipes from sump pump & French drain to empty into rain garden

Rain garden -- 150 sq ft -- see planting detail

River cobble at overflow

T H I R D S T R E E T S O U T H

Berm around lower side of rain garden

26'-0

" (+

/-)

6'-0" (+/-)

asphaltdriveway

Additional conservation planting area

River cobble where pipe daylights into rain garden

Roofs drain directly onto ground below. There is currently a French drain underground along the perimeter of the building.

0 5 10 FT

Outline of previous house addition to be shown with stone band (not part of Arlington StormwaterWise project)

Bal

l-Sel

lers

Hou

se M

useu

m56

20 3

rd S

t. So

uth

Arli

ngto

n, V

A 2

2204

Plan

Vie

w &

Stor

mw

ater

Cal

cula

tions

Arli

ngto

n C

ount

ySt

orm

wat

erW

ise

Prog

ram

Edward ColahanLandscape Design3276 Valley Dr.Alexandria, VA 22302

[email protected]

Dat

e: J

uly

26, 2

016

Scal

e: 1

/8"

= 1'

-0"

Roof 1: 274 s.f. x .08 = 22 cu ftRoof 2: 290 s.f. x .08 = 23 cu ft

Total volume for 1" storm event: 45 cu ft

Infiltration Test Results: 4.7 in/hr.Stormwater calculations for 1" storm event:6" ponding area: 150 s.f. x .5 = 75 cu ft6" bioretention soil: 150 s.f. x .5 x .25 = 18.75 cu ft

Total treatment volume: 93.75 cu ft (or roughly 2" storm event)

Rain garden treatment calculations:

Page 2: Cross Section A - A1 · 2016 Scale: 1/8" = 1'-0" Roof 1: 274 s.f. x .08 = 22 cu ft Roof 2: 290 s.f. x .08 = 23 cu ft ... Ls CvCv Cv Cv CvCv Cv Cv Cv Cv CvCv Ls Ls LsLs Ls Ah Ah Ah

PLANT LIST

TREES & SHRUBS:

Code Botanical Name Common Name Qty. Size

Mp-f Morella (Myrica) pensylvanica - female Northern bayberry 2 36"

Mp-m Morella (Myrica) pensylvanica - male Northern bayberry 1 36"

PERENNIALS & ORNAMENTAL GRASSES:

Code Botanical Name Common Name Qty. Size

Ah Amsonia hubrichtii Bluestar 3 1 gal

At Asclepias tuberosa Butterfly milkweed 8 1 gal

Cv Coreopsis verticillata 'Zagreb' Threadleaf coreopsis 18 1 qt

Ep Echinacea purpurea Purple coneflower 12 1 qt

Ls Liatris spicata Blazing star 7 1 gal

Pa Packera aurea Golden ragwort 18 1 qt

Pv Panicum virgatum'Rotstrahlbusch' Swtichgrass 4 1 gal

Rf Rudbeckia fulgida Black-eyed Susan 12 1 qt

Rh Ruellia humilis Wild petunia 7 1 qt

Ss Schyzachyrium scoparium Little bluestem 11 1 gal

Ssp Solidago sphacelata 'Golden Fleece' Golden Fleece goldenrod 12 1 qt

Sh Sporobolus heterolepis Prairie dropseed 14 1 gal

Ep

Ep

Ep

Cv CvRf

EpPv

Pv

Pv

Pv

AtAt

At At

Ls

CvCv

Cv Cv Cv

Cv Cv

CvCv

Cv

CvCv

CvCvCv

Ls

LsLs Ls Ls

AhAh

Ah

RfRf

Rf

RfRfRf

Rf

Rf

Rf

Rf

Rf

ShSh

Sh

Sh

ShSh

Sh

Sh

Sh

Sh

Sh

Sh

Sh

ShSs

Ss

Ss Ss

Ss

Ss

RhRh

Rh RhRh

Rh

Ep

Ep

Ep

Ep

Ep

Ep

Ep

Rh

AtAt At

At

Cv

Ss

Ss

Ss

Ss

Ss

Ls

Mp-fMp-m

Mp-f

(2) Mp-f - Morella pensylvanica (female)

(14) Sh - Sporobolus heterolepis

(18) Cv - Croeopsis verticillata 'Zagreb'

(8) At - Asclepias tuberosa

(4) Pv - Panicum virgatum

(7) Rh - Ruellia humilis

(7) Ls - Liatris spicata

(18) Pa - Packera aurea

(11) Ss - Schyzachyrium scoparium

(12) Ep - Echinacea purpurea

(12) Rf - Rudbeckia fulgida

(12) Ssp - Solidago sphacelata 'Golden Fleece'

(3) Ah - Amsonia hubrichtii

Planting DetailScale: 1/8" = 1'-0"1

overflow(1) Mp-m - Morella pensylvanica (male)

99989796

Existing grade

Cross Section A - A1Scale: 1/4" = 1'-0"2

Proposed grade

6"

2"

6"

Berm & overflow

car park berm rain garden

2" mulch6" bioretention soil

6" ponding

houselawnlawn

6" ponding

Bal

l-Sel

lers

Hou

se M

useu

m56

20 3

rd S

t. So

uth

Arli

ngto

n, V

A 2

2204

Plan

ting

Det

ail &

Rai

n G

arde

n C

ross

Sec

tion

Arli

ngto

n C

ount

ySt

orm

wat

erW

ise

Prog

ram

Edward ColahanLandscape Design3276 Valley Dr.Alexandria, VA 22302

[email protected]

Dat

e: J

uly

26, 2

016

Scal

e: a

s no

ted

Page 3: Cross Section A - A1 · 2016 Scale: 1/8" = 1'-0" Roof 1: 274 s.f. x .08 = 22 cu ft Roof 2: 290 s.f. x .08 = 23 cu ft ... Ls CvCv Cv Cv CvCv Cv Cv Cv Cv CvCv Ls Ls LsLs Ls Ah Ah Ah
Page 4: Cross Section A - A1 · 2016 Scale: 1/8" = 1'-0" Roof 1: 274 s.f. x .08 = 22 cu ft Roof 2: 290 s.f. x .08 = 23 cu ft ... Ls CvCv Cv Cv CvCv Cv Cv Cv Cv CvCv Ls Ls LsLs Ls Ah Ah Ah
Page 5: Cross Section A - A1 · 2016 Scale: 1/8" = 1'-0" Roof 1: 274 s.f. x .08 = 22 cu ft Roof 2: 290 s.f. x .08 = 23 cu ft ... Ls CvCv Cv Cv CvCv Cv Cv Cv Cv CvCv Ls Ls LsLs Ls Ah Ah Ah