  • KDDBAPI Std 650 Storage Tank

    Data Sheet PAGE 1* For boxes marked with *, if blank, Mfr. Shall determine and submit as per Appendix L. For all lines, see Appendix L for line-by-line instructions.

    Measurement Units to be used in API Std 650: SI US Customary

    1. Manufacturer* Contract No.*

    Address*

    Mfg. Serial No.* Year Built* 12th Edition-Latest

    2. Purchaser Contract No.

    Address

    Tank Designation

    3. Owner/Operator Location Kuwait

    4. Size Limitations* Tank Diameter* 15m Shell Height*

    Capacity: Maximum* Net Working* Criteria*

    5. Products Stored:

    Liquid Crude Oil Max. S.G.: 1.02 at 15.56 C

    Blanketing Gas Vapor Pressure 13 PSIA at Max. Operating Temp.

    % Aromatic Suppl. Spec. Yes No Suppl. Spec.

    Other Special Service Conditions? Yes No Suppl. Spec.

    DESIGN AND TESTING Purchaser to Review Design Prior to Ordering Material? Yes No

    6. Applicable API Standard 650 Appendices:* A B C F G H I J L M O P S U V

    7. Max. Design. Temp. Design Metal Temp.* Design Liquid Level* 8.4 m

    Design Pressure 6.89 kPa External Pressure -3.44 kPa Maximum Fill Rate Maximum Emptying Rate

    Floatation Considerations? Yes No Flot. Suppl. Spec:* Applied Supplemental Load Spec.

    8. Seismic Design? Yes No Appendix E Alternate Seismic Criteria Seismic Use Group

    MBE Site Class D Vertical Seismic Design? Yes No

    Basis of Lateral Acceleration (Select one): Mapped Seismic Parameters? ; Site-Specific Procedures: MCE

    Design Required? Yes No ; Other (Non-ASCE) Methods Sp = 0.075

    Freeboard Required for SUG I Design Roof Tie Rods @ Outer Ring?* Yes No

    9. Wind Velocity for non-U.S. sites, 50-yr. wind speed (3-sec. Gust)* 162 km/Hr

    Top Wind Girder Style* Detail - 'I' Dimensions* Use Top Wind Girder as Walkway? Yes

    Intermediate Wind Girders?* Yes No Intermediate Wind Girder Style* Dimensions*

    Check Buckling in Corroded Cond.? Yes No

    10. Shell Design: 1-Ft Mthd?* Yes No ; Variable-Des-Pt Mthd?* Yes No Alternate ; Elastic Anal. Mthd?* Yes No

    Plate Stacking Criteria* Centerline-Stacked? Yes No Flush-Stacked? Yes No Inside Outside

    Plate Widths (Shell course heights) and Thicknesses * Numbers below Indicate Course Number.

    1. 2400 x 8 2. 2000 x 8 3. 2000 x 8 4. 2000 x 8 5.

    6. 7. 8. 9. 10.

    11. 12. 13. 14. 15.

    Joint Efficiency* % Shell-to-Bottom Weld Type* Shell-to-Bottom Weld Insp. Mthd*

    Approvals: Revisions: Title:

    By: Ck'd:

    Drawing No.: Sheet

    GENERAL Special Documentation Package Requirements:

    Edition & Addendum to API 650*

    1193 m3

    H2S Service?

    120 m3/Hr

    Vertical Ground Motion Accelerator AV:

    Ss S1 S0

  • OF 7

    12th Edition-Latest

    Kuwait

    8.4m

    W

    Maximum Emptying Rate 120 m3/Hr

    Seismic Use Group 1

    Site-Specific Procedures: MCE

    No

    Alternate

    Date:

    Sheet of

  • AMETANKAPI Std 650 Storage Tank

    Data Sheet PAGE 2* If box is blank, Manufacturer shall determine and submit as per Appendix L.

    11. Open-Top and Fixed Roofs: (See Sheet 6 for Floating Roofs) Open Top?* Yes No

    Fixed Roof Type* Cone Roof Support Columns*: Pipe Or Structural Shape

    Cone Slope* 1 : 6 Dome or Umbrella Radius* Weld Joints* Lap(Lap, Butt, Other)

    Seal Weld Underside of: Lap Joints? Yes No ; Seal Weld Underside of Wind Girder Joints? Yes No

    Gas-tight? Yes No Joint Efficiency* %

    Thickness* 7 mm In. Snow Load* App. Suppl. Load Spec.* Column Lateral Load

    Normal Venting Devices* Emergency Venting Devices*

    For Non-Frangible Roofs: Seal Weld Roof Plates to Top Angle on the Inside? Yes No ; Weld Rafters to Roof Plates?

    Roof-to-Shell Detail* Detai 'I' of Annex -F - Fig F-2 Radial Projection of Horizontal Component of Top Angle* Inward Outward

    12. Bottom: Thickness* 10 Style* Cone - Up Slope* 1 : 35 Weld Joint Type* Lap

    Provide Drip Ring? Yes No Alternate Spec.

    Annular Ring? Yes No Annular Ring: Minimum Radial Width* 750 (min) Thickness* 10 mm

    13. Foundation: Furnished by* Type* Ring Wall

    Soil Allow: Bearing Pressure* Per Spec.* Anchors: Size* VTC Qty.*

    Foundation Design Loads: Base Shear Force: Wind* Seismic* Overturning Moment: Wind* VTC Seismic*

    Ring Forces: Weight of Shell + Roof New* Corroded* Roof Live Load* 1.2 kPa Internal Pressure*

    Partial Vacuum* Wind* Seismic*

    Bottom Forces: Floor Wt. New* Corroded* Product Wt.* Water Wt.* Internal Pressure*

    Partial Vacuum* Other Foundation Loads* Min. Projection of Fdn. Above Grade:

    14. Responsibility for Heating Water, if Required: Purchaser Manufacturer

    Hydro-Test Fill Height* 8.4 m Settlement Measurements Required? Yes No Extended Duration of Hydro-Test:

    Predicted Settlement Profile is Attached

    Responsibility for Setting Water Quality: Purchaser Manufacturer Supplemental Test Water Quality Spec.

    Test Water Source & Disposal Tie-In Locations Hydro-Test Appendix J Tank?

    Post-Pressure-Test Activities Required of the Manufacturer: Broom Clean Potable Water Rinse Dry Interior

    Other

    15. Inspection by in Shop;

    Supplemental NDE Responsibility Supplemental NDE Spec.(Purch., Mfg., Other)

    Positive Material Identification? Yes No PMI Requirements:

    Max. Plate Thickness for Shearing

    Yes No Yes

    Leak Test Mthd: Roof* Shell* As per API 650 Shell Noz./Manhole Reinf. Plt*

    Bottom* As per API 650 Floating Roof Components*

    Modify or Waive API Dimensional Tolerances (see 7.5)? No Yes Specify:

    Specify Additional Tolerances, if any, and Circumferential and Vertical Measurement Locations:- Allowable Plumbness: Measure and Record at a Minimum of Locations or Every m (ft) around the Tank, at

    the Following Shell Heights: (select one box): Top of Each Shell Course Other:

    - Allowable Roundness:** Measure Radius and Record at a Minimum of Locations or Everyaround the Tank, at the Following Shell Heights (select one box):

    Top of Tank, H Top of Each Shell Course Other:

    **See Data Sheet Instructions for the Maximum Allowable Additional Radial Tolerance.Approvals: Revisions: Title:

    By: Ck'd:Drawing No.: Sheet

    Must Welds not exceeding 6 mm (1/4 in.) Be Multi-Pass? Must Welds greater than 6 mm (1/4 in.) Be Multi-Pass?

    1/3 H, 2/3 H and H

    1/3 H, 2/3 H and H

  • 2 OF 7

    Lap

    Weld Rafters to Roof Plates? Yes No

    Outward

    Lap

    Ring Wall

    Qty.* VTC

    Seismic* VTC

    Internal Pressure* 6.89 kPa

    Internal Pressure*

    Min. Projection of Fdn. Above Grade:

    Extended Duration of Hydro-Test:

    Supplemental Test Water Quality Spec.

    Yes No

    in Field

    Yes No

    m (ft) around the Tank, at

    m (ft)

    Date:Sheet of

  • AMETANKAPI Std 650 Storage Tank

    Data Sheet PAGE 3

    16. Coatings:Internal Coatings by: Per Spec.* As Per Spec

    (Not Req'd., Others, Tank Mfg.)External Coating by: Per Spec.* As Per Spec

    (Not Req'd., Others, Tank Mfg.)Under-Bottom Coating by: Per Spec.* As per Spec

    (Not Req'd., Others, Tank Mfg.)

    17. Cathodic Protection System? Yes No Per Spec.*

    18. Leak Detection System? Yes No Per Spec.*

    19. Release Prevention Barrier? Yes No Per Spec.*

    20. Tank Measurement System: Required? Yes No Remote Capability Required? Yes No

    By:* Per Spec.*

    21. Weight of Tank: Full of Water* Empty* Shipping* Brace/Lift Spec.*

    22.

    23. Remarks:*1. Nozzle Elevation and Orientation to be confirmed after site visit on contract award2. the T

    Approvals: Revisions: Title:

    By: Ck'd:

    Drawing No.: Sheet

    References:* API Std 650, Appendix L

  • OF 7

    Date:

    Sheet of

  • AMETANKAPI Std 650 Storage Tank

    Data Sheet PAGE 4

    * If box is blank, Manufacturer shall determine and submit as per Appendix L.

    Table 1 MATERIALS OF CONSTRUCTION

    Component Material*/Thickness* C.A. Component Material*

    A 283 Gr C - 8 mm 1.6 Reinforcing Pads A 283 Gr C

    Shell, Course ___ to ___ Manhole/Nozzle Necks A 283 Gr C / A 106 Gr B

    Shell, Course ___ to ___ Manhole/Nozzle Flanges A 283 Gr C / A 105

    Shell, Course ___ to ___ Flange Covers A 283 Gr C

    Shell, Course ___ to ___ Anchor Attachments A 283 Gr C

    Roof A 283 Gr C 1.6 Submerged Piping A 106 Gr B

    Bottom A 283 Gr C 3.2 Wetted Structurals A 36 / S275 JR

    Annular Ring A 283 Gr C 3.2 Non-wetted Structurals A 36 / S275 JR

    + Check here if C.A. is to apply to each exposed surface

    Table 2 BOLTS and ANCHORS

    Component Head Type* Bolt or Anchor Material* Nut Material* Thread Series*

    Flange Bolting HEX A 193 Gr B7 A 194 Gr 2H UN

    Structural Bolting HEX A 327 A563 UN

    Anchor Bolts HEX A 307 / BS4190 A 563 UN

    UN

    ++ Total C.A., on the nominal diameter.

    Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

    Mark Service

    Remaks

    Shell Nozzles

    N1 Inlet 8" WNRF 150# Note-4

    N2 Outlet 8" WNRF 150# Note -5

    N3 Level 3" WNRF 150#

    N4 Level 3" WNRF 150#

    N5 Level 3" WNRF 150#

    N6 Level 3" WNRF 150#

    N7 Spare 4" WNRF 150# W/ Blind

    N8 Drain 3" WNRF 150#

    N9 Foam 4" WNRF 150# VTC

    N10 1" WNRF 150#

    N11 3" WNRF 150#

    N12 Heating Coil 3" WNRF 150#

    N13 Heating Coil 3" WNRF 150#

    N14 Spare 3" WNRF 150# W/ Blind

    N15 Spare 3" WNRF 150# W/ Blind

    N16 Spare 3" WNRF 150# W/ Blind

    M1 Clean Out 24" As per API 650 W/ Cover+Davit

    Approvals: Revisions: Title:

    Shell, Course _1__ to _4__

    Size, NPS, or Dia. (in.)

    Neck Sch or Wall Thick.

    Reinf. Plate Dimensions

    Full Pen. On Open.

    (Y/N)FlangeType

    Flange Class or Thick.

    Proj. to FF or CL or from Datum

    LinesGasket Thick.

    and Dimen.

    Sample Connection.Recirculatio

    n Line

  • By: Ckd:

    Drawing No.: Sheet

  • 4 OF 7

    Table 1 MATERIALS OF CONSTRUCTION

    Material* C.A.

    A 283 Gr C 1.6

    A 283 Gr C / A 106 Gr B 1.6

    A 283 Gr C / A 105

    A 283 Gr C

    A 283 Gr C 1.6

    A 106 Gr B 1.6

    A 36 / S275 JR 1.6 +

    A 36 / S275 JR 1.6 +

    + Check here if C.A. is to apply to each exposed surface

    Table 2 BOLTS and ANCHORS

    Thread Series* C.A.

    UN ++

    UN ++

    UN ++

    UN

    ++ Total C.A., on the nominal diameter.

    Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

    Remaks

    Shell Nozzles

    Note-4

    Note -5

    W/ Blind

    VTC

    W/ Blind

    W/ Blind

    W/ Blind

    W/ Cover+Davit

  • Date:

    Sheet of

  • AMETANKAPI Std 650 Storage Tank

    Data Sheet PAGE 5

    * If box is blank, Manufacturer shall determine and submit as per Appendix L.

    Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

    Mark Service

    Remaks

    ROOF Nozzles

    N17 VENT 2" WNRF 150# GAS

    N18 4" WNRF 150# Note -5

    N19 24" WNRF 150# W/ Emergency Vent

    N20 PVSV 6" WNRF 150#

    M2 Manhole 24" As per API 650 W / Cover + Davit

    N21 MTG LVL 2" WNRF 150#

    N22 Spare 2" WNRF 150# W/ Blind

    N23 Spare 2" WNRF 150# W/ Blind

    Clean Out 24" As per API 650 W/ Cover+Davit

    Approvals: Revisions: Title:

    By: Ckd:

    Drawing No.: Sheet

    Size, NPS, or Dia. (in.)

    Neck Sch or Wall Thick.

    Reinf. Plate Dimensions

    Full Pen. On Open.

    (Y/N)FlangeType

    Flange Class or Thick.

    Proj. to FF or CL or from Datum

    LinesGasket Thick.

    and Dimen.

    BLANKET GAAS

    Emergency Vent

  • OF 7

    Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

    Remaks

    ROOF Nozzles

    GAS

    Note -5

    W/ Emergency Vent

    W / Cover + Davit

    W/ Blind

    W/ Blind

    W/ Cover+Davit

    Date:

    Sheet of

  • AMETANKAPI Std 650 Storage Tank

    Data Sheet PAGE 6

    * If box is blank, Manufacturer shall determine and submit as per Appendix L.

    OTHER TANK APPURTENANCES

    24. Platform, Stairway, and Railing: Galvanizing Req'd?* Yes No Stairway Style* Spiral Walk Surf. Type*(Straight or Helical)

    Stair and Walkway Clear Width* 1000 mm National Safety Standards*

    Architectural/Structural Specification*

    Gauger's Platform Req'd? Yes No Qty. Req'd* 1 Per Spec.*

    25. Jacket Required?* Yes No Other Heaters/Coolers Required?* Yes No

    Supplemental Jacket, Heater, or Cooler Specifications*

    26. Mixer/Agitator: Quantity Size* Per Spec.*

    27. Insulation: Required? Yes No Thickness* Material*

    Per Specs* Responsibility for Insulation and Installation(Purchaser, Manufacturer, Others)

    28. Structural Attachments: Lift Lugs?* Yes No Desc.*

    Shell Anchorage?* Yes No Type* Scaffold Cable Support?

    29. Various Other Items: Welded Flush-Type: Shell Connection Cleanout Fitting Waive Application of Appendix P?

    Miscellany #1 Heating Coil Miscellany #2

    Miscellany #3 Miscellany #4

    Miscellany #5 Miscellany #6

    Table 4 OTHER TANK APPURTENANCES*

    Mark Quantity Size Orientation Height from Datum Material

    Approvals: Revisions: Title:

    By: Ck'd:

    Drawing No.: Sheet

    Service or Description

  • OF 7

    Greating

    (Purchaser, Manufacturer, Others)

    Yes No

    Yes No

    Table 4 OTHER TANK APPURTENANCES*

    Material Remarks

    Date:

    Sheet of

  • AMETANKAPI Std 650 Storage Tank

    Data Sheet PAGE 7

    * If box is blank, Manufacturer shall determine and submit as per Appendix L.

    Tank Plan and Sketches:

    Notes:

    Approvals: Revisions: Title:

    By: Ck'd:

    Drawing No.: Sheet

  • OF 7

    Date: