1. All dimensions are in millimetres unless otherwise noted.
2. All levels are in metres above Ordnance Datum (mAOD).
3. Do not scale from this drawing.
4. This drawing shall only be used for the design element stated in the drawing title.
5. For details of high friction surfacing refer to Pavement or General Arrangement drawing.
6. For details of Tactile paving refer to Pavement or General Arrangement drawing.
7. All tactile paving to be laid at gradient of 1 in 20 desirable to 1 in 12 maximum
8. Controller, communications equipment enclosure, electricity supply pillar and all pole locations to be agreed with the CYC
Traffic Signal Engineer before associated installation works commence.
9. Controller will normally run VA but shall be connected to UTC for fault reporting, data collection and if required (fixed time)
UTC control;
10. The Controller base shall be a NAL 'cabinet style' appropriate for the controller type.
11. The controller shall incorporate an integral UG405 OTU facility (32 control and 32 reply bits) and include an armoured
cable to the fibre termination device in the communications cabinet.
12. TrafiCams (wide angle) and ThermiCams (wide angle) cameras mounted on extension brackets shall be utilised to
detect vehicular traffic and cyclists. TrafiCams cameras are mounted on Poles 8, 9, 10 and 13 and a ThermiCam on Pole 2;
13. TrafiCams and ThermiCams shall be cabled back to the controller using externalised cable. Adequate I/O shall be
provided in the controller.
14. Communications to the site shall be provided utilising the CYC 'dark fibre' which shall be arranged (including supply of
a fibre termination device), installed and commissioned in the Communications Equipment Enclosure (CEE) by CYC.
15. The traffic signals contractor shall install an externalised CAT6a cable between the CEE and the top of the Pole 12 (6m
pole) leaving 3m spare at each end.
16. CYC shall supply and install a CCTV camera on Pole 12 (6m pole), connect to the externalised CAT6a cable, connect
the externalised CAT6a cable to the fibre termination device and commission the CCTV.
17. CCTV and communications cabling shall utilise traffic signal ducting.
18. No signal equipment shall be installed with less than 450mm clearance from the kerbface.
19. All street furniture to be black.
20. PDUs shall have combined pushbuttons and displays, standard field of view, and the alignment shall be agreed on site
with the CYC Traffic Signal Engineer. Tactile cones to be fitted to the right hand unit only.
21. Audible devices are not used.
22. Island to south is 3.0m wide and the northerly island 2.1m
23. All works shall comply with the latest edition of the City of York Council Traffic Signal Installation Requirements
(currently Version 9.2).
e-mail: [email protected]
Tel 0113 200 8904
0113 270 1199
www.metengineers.com
Southgate House
Pontefract Road
Stourton, Leeds
West Yorkshire
LS10 1SW
Met Engineers Ltd
Ch'k'dDescriptionDrawnDateRev
Client
Project
Title
Drawn
Date
Checked
Date
Scale
StatusOriginal Size
Drawing No Rev
Persimmon Homes
Fullford, York
(All Phases)
Traffic Signal Design
PH
May 2014
BJS
May 2014
1:250
A0Construction
11644/5007/S278-393 L
General
1. Do not scale dimensions from this drawing in either paper or
electronic format.
2. To be read in conjunction with all relevant Engineer's,
Architect's and Other drawings and specifications.
3. All building products to be used in strict accordance with the
manufacturer's recommendations.
4. Any discrepancies are to be reported to the Engineer
immediately.
5. Main Contractor to provide a detailed method statement for
all works prior to commencement on site.
BJS
PHLayout revised to suit York Council
A 11.06.14
comments dated 05.06.14.
Secondary RAGA (ahead) Signal Head
Primary RAG/A (ahead) Signal Head
Secondary RAG+ G/A (left) Signal Head
Primary RAG+G/A (left) Signal Head. pole twisted by 45 degrees
Primary RAG Signal Head, pole twisted by 45 degrees
Primary RAG Signal Head
BJS
PHLayout revised to suit York Council
B 18.06.14
comments dated 16.06.14.
BJSPHLayout altered to suit York Council C
30.06.14
comments.
BJSAKWhite lining adjusted.D
30.10.14
NOTE:
Drawing to be read in conjunction with
Drawing No. 11644/5007/S278-371 M
BJSSSGeneral reference note added.E
13.11.14
BJSTVFootway widened South side of F
13.01.15
Fordlands road (N)
BJSPHAmended to suit CYC comments.G 30.08.16
PHSSDrawing updated to ConstructionH
21.10.16
PHSSA19 Kerbline re-aligned, drawingJ
09.01.17
updated to suit.
Revision Cloud
Photo Electric Cell
MVD
Virtual Queue loop
Virtual loop
Push Button
Pedestrian Demand Unit (PDU) (Narrow field of vision)
Pedestrian Demand Unit (PDU) (Standard field of vision)
CCTV Camera
On crossing detector
FLIR TrafiCam (Wide Angle) mounted on extension bracket
FLIR ThermiCam (Wide Angle)
Primary RAG/A (left) Signal Head
Secondary RAG/A (left) Signal Head
4m Pole Straight
6m Pole Straight
Reduced Height pole for demand units(2.4m)
Short Pole for pushbuttons (2.2m)
Controller
Comunications Equipment Enclosure
(Ritherdon RB600 complete with root or similar approved).
Electrical Supply Pillar
Pole Numbering
KEY
SSSHAmended to suit updated signal layout.K
02.03.17
1
Secondary RAG+ G/A (right) Signal Head
SSSHAmended to suit consulatnts comments.L
03.03.17