ct-v900-a door hardware new version 5 · • pro-report features: a. new short time &...
TRANSCRIPT
Programmable outPuts
reader 1 reader 2out 1(Default: Green LED)
out 3(Default: Green LED)
out 2(Default: Red LED)
out 4(Default: Red LED)
out 5(Default: Buzzer)
out 6(Default: Buzzer)
Zone inPuts
Without atZ (Zone doubling) With atZ (Zone doubling)Z1Default:Contact door 1
Z2
Z3Default:REX door 1
Z4
Z5 Z6
Z7 Z8
Z9Default:Contact door 2
Z10
Z11Default:REX door 2
Z12
Z13 Z14
Z15 Z16
relaysRelay 1(Onboard)
Relay 2(Onboard)
adding one relay expansion adding a second relay expansion
Relay 3 Relay 10
Relay 4 Relay 11
Relay 5 Relay 12
Relay 6 Relay 13
Relay 7 Relay 14
Relay 8 Relay 15
Relay 9 Relay 16
c d v i . c a
CT-V900-A Door HArDwAre
manufacturing access Control since 1985
Improvements and built-in features:Centaur improvements:• Automaticallye-mailscheduledreports
• CardUsage/CardCounteroptions (useacardupto255timesonadoor)
• Alarmintegration:arming/disarmingan alarmpanelondualbadge(keyswitchinput)
Visitor ManagementCentaurVisitorManagementwillallowyoutose-curelycontrolthecomingsandgoingsofallvisitors.
Parking ManagementTheCentaurParkingManagementallowsyoutoquicklyseehowmanyparkingplacesareused,bywhichuserandhowmanyparkingspacesareavailableinrealtime.
LocatorMonitorthelocation(inside/outside)ofeachcardholderinreal-time.View/Printreportswithaclickofabutton.Obtaindetailedcardholderinformationwithadouble-clickofthemousebutton.Excellentformuster-pointapplications.
Print or e-mail reports of your activitiesTracktheaccessesofaspecificemployee,verifywhoaccessedaspecificdoorataprecisedateandtimeorcalculatehowmanyhoursofovertimeyouwillpay.Centaurreportwizardallowsyoutocreateyourownreportseasily.
Live Interactive Floor Plans • Createorimportupto512floorplans• Fulllibraryoficons(orcreateyourown)• Event-basedtrigger-actions
Centaur video module (DVR) lets you playback up to 60 seconds before and after a specific event. It also lets you capture a video image (frame) during the playback or live camera viewing in jpeg format.
In Constant Evolution
to fulfill your needs
in access control
New Version 5.1
New features in CeNTAUr Version 5.1:Guard Tour FeatureLive interactive guard tour allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. Includes live alarms for time violations and intuitive exception reports.
Asset Management FeatureWhybuysomethingthatyoualreadyhave?Keeptrackofyourassetsandsavetimeandmoney.Findquicklywhoisinpossessionofyourassets.Areportcanbegeneratedandsentautomaticallyviaemail.
Biometric IntegrationCentaurisapowerfulsolutionforareasrequiringenhancedsecuritybyauthenticatingfingerprints.Capturing,managingandtransferringbiometricdataisnoweffortlesswithworld-renownedfingerprintreaderssuchasCDVI’sDGID/W/US,L-1(model4G),Sagemandmore.
CeNTAUr 5.1 now supports the followingDVr manufacturers:
• Capture• Dahua• Dedicated Micros• Digiop• Digital WatchDog• Eneo• Everfocus• HIK Vision• Infinova• Microcom• Milestone• NUUO• Samsung• Sphere• ViewGate• Vivotek IP Camera• Vivotek
c d v i . c a c d v i . c a
Access level 1: __________________________
Schedule 1*: ___________________________
Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq
Door: 1 2 3 4 5 6 7 8 qqqqqqqq
Access level 2: __________________________
Schedule 2*: ___________________________
Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq
Door: 1 2 3 4 5 6 7 8 qqqqqqqq
Access level 3: __________________________
Schedule 3*: ___________________________
Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq
Door: 1 2 3 4 5 6 7 8 qqqqqqqq
Access level 4: __________________________
Schedule 4*: ___________________________
Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq
Door: 1 2 3 4 5 6 7 8 qqqqqqqq
aCCess leVels and sChedules deFinition
Card user name Card numberFamily : Number aCCess leVel
1: : 2: : 3: : 4: : 5: : 6: : 7: : 8: : 9: : 10: : 11: : 12: : 13: : 14: : 15: : 16: : 17: : 18: : 19: : 20: :
* HH:MM to HH:MM
Key FeATUres IN VersIoN 5.1• Guard Tour features: Allows check point validation using card readers, input points (Motion sensors, key
switches, or push buttons) or data collectors.• Asset Management, find quickly who is in possession of your assets and for how long.• Biometrics integration (CDVI’s DGID/W/US, L-1 model 4G, Sagem and more)• Alarm integration: Arm/disarm an alarm system with a double card swipe• Card Usage/Card Counter options (use a card up to 255 times on a door) • All reports including Time & Attendance reports can be sent automatically by e-mail• Unassign card on period of inactivity (up to 365 days)• New DVR support (see the list on the front page)• Import/export users, cards and all related objects• Manually control doors from event window• New controller standalone functionality a. Activate relay on access granted, extended access (Disabled person) b. Activate relay on door forced open status c. Activate relay on door open too long status d. Relay follow input (keep light open on movement) e. Maintain door locked/unlocked on valid card (classroom application)• Play waves on alarm from the administration console• Additional filters in Locator• Now support DNS in the controller properties• Added French support in WavePlayer• Parking group: Reset parking count• SAP import for users/cards• When User/Visitor status is changed, it is now reflected on the cards• Support TELACCESS• Support DGLM magnetic stripe reader• Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management dialog (Add, Delete, Modify and etc.). e. New usage billing report f. New access report type (access granted only) g. New option in Tracker Preferences (show valid users only)
INTEGRATED ACCESS CONTROL
sITe CoNFIgUrATIoN QUICK Form
imPortant --- imPortant Please note that Centaur 5.1 version is compatible with Centaur 5.0 Dongles.
Firmware update of CT-V900-A will be necessary to perform new 5.1 features. See details below:R2-C3-98 - Works with Centaur 5.1 and support up to 8,190 cards
R2-G3-98 - Works with Centaur 5.1 + LCD Tracker feature and support up to 4,914 cards
c d v i . c a c d v i . c a
Project: _______________________________ Door Name:_______________________
Door contact � Surface � Flush
� Electromagnet� 24V � 12V
� Door Strike � 24V � 12V� Fail Safe � Fail Secure
REQUEST-TO-EXIT (REX)� Motion Detector� Pull Station� Push Button� Push Bar/Crash Bar
READING DEVICE (ENTRY)� Reader Technology:_______________� Keypad Technology:_______________
READING DEVICE (EXIT)� Reader Technology:_______________� Keypad Technology:_______________
� Fixed Door
Electromagnet �24V � 12V �
Door contact � Surface � Flush
Fixed Door �
DOUBLE-DOOR OPTION
door typeq Access (Most common setting)q Elevatorq Entry Anti-passback (1 CT-V900-A only, 8 readers)q Exit Anti-passback (1 CT-V900-A only, 8 readers)q Global Entry Anti-passback (multiple doors)q Global Exit Anti-passback (multiple doors)q Parking Global Entry Anti-passbackq Parking Global Exit Anti-passbackq Two Card Rule
optionsq Unlock on late open (Ignore the unlock schedule until the first person arrives) q Time and attendanceq Sign-Out reader (Visitor)
unlock schedule (optional)Schedule time (HH:MM): __________________
Days: S M T W T F S qqqqqqq
interlock (man-trap)With door (input): _________________________
door Programming
CT-V900-A Door HArDwAre
liteCs-aC-lite
standardCs-aC-std
ProfessionalCs-aC-Pro*
enterpriseCs-aC-ent*
Free**
starter PaCk
sites 1 64 64 64 1
serial Ports 1 1 1 4 4
dial up connection Yes Yes Yes Yes Yes
tCP/iP connection Yes Yes Yes Yes Yes
Cards 512 2,048 per site(131,072 max.)
8,196 per site(524,544 max.)
16,384 per site(1,048,576 max.) 512
Controllers 16 32 per site(2,048 max.)
64 per site(4,096 max.)
256 per site(16,384 max.) 1
doors 16 128 per site(8,192 max.)
512 per site(32,768 max.)
2048 per site(131,072 max.) 8
elevator Control - Yes Yes Yes Yes
elevator Cabs - 64 per site(4,096 max.)
128 per site(8,192 max.)
512 per site(32,768 max.) 2
Floors per cab - 64 64 64 64
Floor groups - 128 per site(8,192 max.)
128 per site(8,192 max.)
128 per site(8,192 max.) 128
dVr module - Yes Yes Yes Yes
Visitor management - Yes Yes Yes Yes
Parking management - Yes Yes Yes Yes
guard tour - Yes Yes Yes Yes
asset management - Yes Yes Yes Yes
* Comes with a workstation license New ** Free from our web site, www.cdvi.ca Security dongle not required
INTEGRATED ACCESS CONTROL Version 5.1
Workstation license (Cs-WsliC):Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console and all software modules.
enhanced security dongle. Previous dongle not supported by Centaur V5.0 and 5.1
every Centaur edition includes a Centaur server with an administration console plusall these software modules:Pro-report with tracker: On demand, scheduled or customized reportsFrontView: Live interactive floor plansFrontguard: Display real-time visual authenticationFrontdesk: Create, modify, delete and print cards, include Photo-IDlocator: Monitor real-time location of each card holderWavePlayer: Play a sound on any system event
c d v i . c a c d v i . c a
E-bus Network Jumper settingsEOL= OFF
Bias High/Low JumpersA+= HighB-= High
START POINTof the RS-485 E-bus network. (Furthest modules can be up to 1220m (4000ft) from start point)
END POINTof the RS-485 E-bus network
CT-V900-A2-Door Controller
CT-V900-A
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
E-bus Network Jumper settingsEOL= OFF
Bias High/LowA+= HighB-= High
CA-A480-A
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
E-bus Network Jumper settingsEOL= ON
Bias High/LowA+= HighB-= High
CA-A480-A
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
E-bus Network Jumper settingsEOL= OFF
Bias High/LowA+= HighB-= High
CA-A470-A
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
E-bus Network Jumper settingsEOL= ON
Bias High/LowA+= LowB-= Low
CA-A470-A
JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE WITH THE CT-V900-A NO LONGER THE START POINT
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
This example depicts an existing RS-485 E-bus network with 1 CA-A470-A and 2 CA-A480-A to which we are adding a CA-A470-A after the initial installation.
In our example the END POINT, the CA-A480-A, is at 914m (3000ft) from the CT-V900-A and the new CA-A470-A module you would like to add is 30m (100ft) from the CT-V900-A.
The flexibility of the RS-485 E-bus network jumpers permits you to locate the new CA-A470-A close to the CT-V900-A by simply re-configuring jumper settings of the new START POINT and what was the start point before.
This permits you to have a 30m (100ft) cable run instead of914m (3000ft).
Addressable dipswitch
Addressable dipswitch Addressable dipswitch Addressable dipswitch
Centaur System Architecture
LCD DisplayCK-TRAK-L
(Max. 8 per CT-V900-A)
Elevator ControllerCA-A480-A
(Max. 8 per CT-V900-A)
Relay Expansion ModuleCA-A460-P
(Max. 2 per CT-V900-A)
2-Door Expansion ModuleCA-A470-A
(Max. 3 per CT-V900-A)
to other Ct-V900-a controllers
E-bus NEtwork ModulE CapaCity
to PC Centaur serverSee diagram above Furthest modules
can be up to 1220m (4000ft) away from the
CT-V900-A
Digital Video Recorder (DVR)
IP Camera
OptionalWorkstation(s)
Printer(Also direct connection can be use)
TCP/IPConnection(LAN/WAN)
CentaurDoor Controller
Director
dial-up (modem)connections
also supported
Burglar AlarmIntegration
Centaur built-in modules:Pro-report: Print detailed reportFrontView: Live interactive floor plansFrontguard: Display real-time visual authenticationFrontdesk: Create, modify, delete and print cardslocator: Monitor card holder location in real-timeWavePlayer: Play a sound on any system event
c d v i . c a c d v i . c a
sITe CoNFIgUrATIoN QUICK FormCompany name: ___________________________
Address: _________________________________
City: _____________________________________
State: ____________________________________
Zip Code: _________________________________
Contact 1: ________________________________
Tel: ______________________________________
Contact 2: ________________________________
Tel: ______________________________________
Contact 3: ________________________________
Tel: ______________________________________
qDirect serial port qRS-232 NULL modem cable qConverter (25’ and more)
qDial Up (modem) Modem number: ____________________________________
qTCP/IP IP Address: ________________________________________
PC (Centaur server) to controller communication type
doors name reader door Contact
requestto exit
door strike maglock Pull
station
1: q Entry q Exit q q q q q
2: q Entry q Exit q q q q q
3: q Entry q Exit q q q q q
4: q Entry q Exit q q q q q
5: q Entry q Exit q q q q q
6: q Entry q Exit q q q q q
7: q Entry q Exit q q q q q
8: q Entry q Exit q q q q q
Dealer: ________________________________
Tel: ___________________________________
installation diagram2 Reader/Keypads per CT-V900-A or CA-A470-A
Ct-V900-a (1)
Door: ____________
Door: ____________
Ct-a470-a (1)
Door: ____________
Door: ____________
Ct-a470-a (2)
Door: ____________
Door: ____________
Ct-a470-a (3)
Door: ____________
Door: ____________
CT-V900-A2-Door Controller
RS-232 7.6m (25ft) max.
Controller Network Jumper settingsEOL= ON
Bias High/Low JumpersA+= LowB-= Low
Controller Network Jumper settingsEOL= OFF
Bias High/Low JumpersA+= HighB-= High
Controller Network Jumper settingsEOL= ON
Bias High/Low JumpersA+= HighB-= High
START POINTof the RS-485 controller network. (Furthest module can be up to 1220m(4000ft) from start point)
END POINTof the RS-485 controller network
CT-V900-A
CT-V900-A
CT-V900-A2-Door Controller
CT-V900-A
CT-V900-A2-Door Controller
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 CONTROLLER NETWORK USING
DIRECT CONNECT CONFIGURATION
Example of Jumper Settings
HIGH
HIGH
EOL
EOL
LOW
LOW
Jumper set to LOW
Jumper set to HIGH
Jumper set to EOL ON
Jumper set to EOL OFF
CONTROLLER NETWORK JUMPERS
ADDRESSABLE DIPSWITCH
E-BUSNETWORK JUMPERS
CT-V900-A CUT VIEW
At the START POINT and the END POINT of the RS-485 controller network, the controllers’ EOL jumpers= ON. All controllers in between EOL= OFF
At the START POINT of the RS-485 controller network, the controllers’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH
Addressable dipswitch
Addressable dipswitch
Addressable dipswitch
c d v i . c a c d v i . c a
ProduCts Quantity 26-bits Wiegand keyPads
galeo/W: 26-bit Wiegand keypad, integrated Piezo/Buzzer, 12Vdc, potted electronics, polished heavy-duty ZAMAK cast alloy (Zinc, Aluminium, Magnesium and Copper)
Proximity Card and badges qBP: leather key ring badge qCS: Clamshell card qISO: Printable card
qBTAG: Blue polycarbonate key ring badge
qPP: Stylish black polycarbonate tear drop badge
rs-485 to rs-232 ConVerter - Ca-a360-a rs-485 to usb/rs-232 ConVerter - Ca-a360-usb rs-232 tCP/iP ConVerter - Ca-ethr-a modem door strike Strike ANSI fail secure: qAR (12VAC/CC) qAR24 (24VCC) Strike ANSI fail safe: qARI (12VCC) qARI24 (24VCC) Strike ANSI continous fail secure: qARCC (12VCC) Strike EFF-EFF fail secure: qAG (12VAC/CC) qAG24 (24VCC) Strike EFF-EFF fail safe: qAGI (12VCC) qAGI24 (24VCC) Strike EFF-EFF continous fail secure: qAGCC (12VCC)
eleCtromagnets V5S: 1100lbs (500kg) holding force, surface mount, 12/24Vdc
V5EI: 1100lbs (500kg) holding force, sliding door applications, flush mount, 12/24Vdc
VSI5R: 1100lbs (500kg) holding force, exterior applications & High-traffic areas, 12/24Vdc
CZ3000: 3000lbs (1500kg) holding force, self-Aligning, 12/24Vdc
Pull station loCk Control module - Ca-a110-P door ContaCt qFlush mount qSurface mount
reQuest to exit Motion detector
BPEST: Touch-to-Exit button
BEI: Stainless steel touch-sensitive handle
POI: Touch-sensitive electronics built-in in the handle, 14” x 2” (39.5cm x 5cm)
EST: Transforms any metallic surface into a request-to-exit device
rs-485 netWork hub - Ca-a370-P qPieZo: q sirene: biometriC Finger Print reader (dgid/W) other:
CT-V900-A2-Door Controller
PO
SIT
ION
GNDTX
B-
+12V
RXGND
A+GND
RE
CE
IVE
TRA
NS
MIT
PO
WE
R
CA
-A36
0-A
Controller Network Jumper settingsEOL= ON
Bias High/Low JumpersA+= LowB-= Low
Controller Network Jumper settingsEOL= OFF
Bias High/Low JumpersA+= HighB-= High
Controller Network Jumper settingsEOL= OFF
Bias High/Low JumpersA+= HighB-= High
Controller Network Jumper settingsEOL= ON
Bias High/Low JumpersA+= HighB-= High
START POINTof the RS-485 controller network.(Furthest modules can be up to 1220m (4000ft) from start point)
END POINTof the RS-485 controller network
CT-V900-A
CT-V900-A
CT-V900-A2-Door Controller
CT-V900-A
CT-V900-A2-Door Controller
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 CONTROLLER NETWORK USING A
CA-A360-A CONVERTER
RS-2327.6m (25ft) max.
Since the converter is now the closest to the server, it is the START POINT.
The converter’s EOL jumper is ON by default and its HIGH/LOW bias jumpers are LOW by default.
Addressable dipswitch
Addressable dipswitch
Addressable dipswitch
7.6m (25ft) max.
HArDwAre LIsT
c d v i . c a c d v i . c a
HArDwAre LIsT
Company Name: ________________________
Address: ______________________________
City: __________________________________
State: _________________________________
Zip Code: ______________________________
Name: ________________________________
Title: __________________________________
Tel: ___________________________________
Cell: __________________________________
E-mail: ________________________________
door tyPe
Controlled entry with Free exit Controlled entry and exit
FrontDoor
Employees Door
To next controller
Requestto exit
Requestto exit
To access control server
Entryreader
Doorstrike*
Entryreader
CT-V900Controller
#1
AC
Doorstrike*
* Can be replace by electromagnet
To access control server To next controller
AC
CT-V900-AController
#1
Door contact
Protected Door
Entry reader
Exit readerDoorstrike*
RS-485 Communication bus
* Can be replace by electromagnet
ProduCts Qty
2-door Controller - Ct-V900-a 2-door exPansion module - Ca-a470-a (3 max. per CT-V900-A controller) 12V-7Ah battery (You need 2 per CT-V900-A and 1 per CA-A470-A or CA-A480-A) CdVi150 transformer: 16VAC and 24VAC,150VA (One CDVI150 transformer can supply one CT-V900-A and tree CA-A470-A)
Proximity reader With multiPle ProtoColes built-in
DGLP FN WLC: Multi-Technology Polycarbonate proximity reader
DGLP WLC: Multi-Technology Polycarbonate proximity reader
DGLI F WLC: Multi-Technology Stainless steel proximity reader
DGLI WLC: Multi-Technology Stainless steel proximity reader
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
+S
P+1
2VR
1/K
PD
R1/
KP
CR
1/K
PB
R1/
KPA
OU
T2O
UT1
R1/
D1
R1/
D0
R1/
0VR
1/+5
V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
E-bus Network Jumper settingsEOL= OFF
Bias High/LowA+= HighB-= High
E-bus Network Jumper settingsEOL= OFF
Bias High/LowA+= HighB-= High
E-bus Network Jumper settingsEOL= OFF
Bias High/LowA+= HighB-= High
E-bus Network Jumper settingsEOL= ON
Bias High/LowA+= HighB-= High
E-bus Network Jumper settingsEOL= ON
Bias High/Low JumpersA+= LowB-= Low
START POINTof the RS-485 E-bus network(Furthest module can be up to1220m (4000ft) from start point)
END POINTof the RS-485E-bus network
CT-V900-A2-Door Controller
CT-V900-A
CA-A480-A CA-A480-A
CA-A470-A CA-A470-A
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 E-BUS NETWORK
At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF
At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH
Addressabledipswitch
Addressabledipswitch
Addressabledipswitch
Addressabledipswitch
c d v i . c a c d v i . c a
E-bus Network Jumper settingsEOL= OFF
Bias High/Low JumpersA+= HighB-= High
START POINTof the RS-485 E-bus network. (Furthest modules can be up to 1220m (4000ft) from start point)
END POINTof the RS-485 E-bus network
CT-V900-A2-Door Controller
CT-V900-A
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
E-bus Network Jumper settingsEOL= OFF
Bias High/LowA+= HighB-= High
CA-A480-A
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
E-bus Network Jumper settingsEOL= ON
Bias High/LowA+= HighB-= High
CA-A480-A
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
E-bus Network Jumper settingsEOL= OFF
Bias High/LowA+= HighB-= High
CA-A470-A
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
E-bus Network Jumper settingsEOL= ON
Bias High/LowA+= LowB-= Low
CA-A470-A
JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE WITH THE CT-V900-A NO LONGER THE START POINT
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
This example depicts an existing RS-485 E-bus network with 1 CA-A470-A and 2 CA-A480-A to which we are adding a CA-A470-A after the initial installation.
In our example the END POINT, the CA-A480-A, is at 914m (3000ft) from the CT-V900-A and the new CA-A470-A module you would like to add is 30m (100ft) from the CT-V900-A.
The flexibility of the RS-485 E-bus network jumpers permits you to locate the new CA-A470-A close to the CT-V900-A by simply re-configuring jumper settings of the new START POINT and what was the start point before.
This permits you to have a 30m (100ft) cable run instead of914m (3000ft).
Addressable dipswitch
Addressable dipswitch Addressable dipswitch Addressable dipswitch
Centaur System Architecture
LCD DisplayCK-TRAK-L
(Max. 8 per CT-V900-A)
Elevator ControllerCA-A480-A
(Max. 8 per CT-V900-A)
Relay Expansion ModuleCA-A460-P
(Max. 2 per CT-V900-A)
2-Door Expansion ModuleCA-A470-A
(Max. 3 per CT-V900-A)
to other Ct-V900-a controllers
E-bus NEtwork ModulE CapaCity
to PC Centaur serverSee diagram above Furthest modules
can be up to 1220m (4000ft) away from the
CT-V900-A
Digital Video Recorder (DVR)
IP Camera
OptionalWorkstation(s)
Printer(Also direct connection can be use)
TCP/IPConnection(LAN/WAN)
CentaurDoor Controller
Director
dial-up (modem)connections
also supported
Burglar AlarmIntegration
Centaur built-in modules:Pro-report: Print detailed reportFrontView: Live interactive floor plansFrontguard: Display real-time visual authenticationFrontdesk: Create, modify, delete and print cardslocator: Monitor card holder location in real-timeWavePlayer: Play a sound on any system event
c d v i . c a c d v i . c a
sITe CoNFIgUrATIoN QUICK FormCompany name: ___________________________
Address: _________________________________
City: _____________________________________
State: ____________________________________
Zip Code: _________________________________
Contact 1: ________________________________
Tel: ______________________________________
Contact 2: ________________________________
Tel: ______________________________________
Contact 3: ________________________________
Tel: ______________________________________
qDirect serial port qRS-232 NULL modem cable qConverter (25’ and more)
qDial Up (modem) Modem number: ____________________________________
qTCP/IP IP Address: ________________________________________
PC (Centaur server) to controller communication type
doors name reader door Contact
requestto exit
door strike maglock Pull
station
1: q Entry q Exit q q q q q
2: q Entry q Exit q q q q q
3: q Entry q Exit q q q q q
4: q Entry q Exit q q q q q
5: q Entry q Exit q q q q q
6: q Entry q Exit q q q q q
7: q Entry q Exit q q q q q
8: q Entry q Exit q q q q q
Dealer: ________________________________
Tel: ___________________________________
installation diagram2 Reader/Keypads per CT-V900-A or CA-A470-A
Ct-V900-a (1)
Door: ____________
Door: ____________
Ct-a470-a (1)
Door: ____________
Door: ____________
Ct-a470-a (2)
Door: ____________
Door: ____________
Ct-a470-a (3)
Door: ____________
Door: ____________
CT-V900-A2-Door Controller
RS-232 7.6m (25ft) max.
Controller Network Jumper settingsEOL= ON
Bias High/Low JumpersA+= LowB-= Low
Controller Network Jumper settingsEOL= OFF
Bias High/Low JumpersA+= HighB-= High
Controller Network Jumper settingsEOL= ON
Bias High/Low JumpersA+= HighB-= High
START POINTof the RS-485 controller network. (Furthest module can be up to 1220m(4000ft) from start point)
END POINTof the RS-485 controller network
CT-V900-A
CT-V900-A
CT-V900-A2-Door Controller
CT-V900-A
CT-V900-A2-Door Controller
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 CONTROLLER NETWORK USING
DIRECT CONNECT CONFIGURATION
Example of Jumper Settings
HIGH
HIGH
EOL
EOL
LOW
LOW
Jumper set to LOW
Jumper set to HIGH
Jumper set to EOL ON
Jumper set to EOL OFF
CONTROLLER NETWORK JUMPERS
ADDRESSABLE DIPSWITCH
E-BUSNETWORK JUMPERS
CT-V900-A CUT VIEW
At the START POINT and the END POINT of the RS-485 controller network, the controllers’ EOL jumpers= ON. All controllers in between EOL= OFF
At the START POINT of the RS-485 controller network, the controllers’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH
Addressable dipswitch
Addressable dipswitch
Addressable dipswitch
c d v i . c a c d v i . c a
Access level 1: __________________________
Schedule 1*: ___________________________
Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq
Door: 1 2 3 4 5 6 7 8 qqqqqqqq
Access level 2: __________________________
Schedule 2*: ___________________________
Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq
Door: 1 2 3 4 5 6 7 8 qqqqqqqq
Access level 3: __________________________
Schedule 3*: ___________________________
Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq
Door: 1 2 3 4 5 6 7 8 qqqqqqqq
Access level 4: __________________________
Schedule 4*: ___________________________
Period: S M T W T F S H1 H2 H3 H4 qqqqqqq qqqq
Door: 1 2 3 4 5 6 7 8 qqqqqqqq
aCCess leVels and sChedules deFinition
Card user name Card numberFamily : Number aCCess leVel
1: : 2: : 3: : 4: : 5: : 6: : 7: : 8: : 9: : 10: : 11: : 12: : 13: : 14: : 15: : 16: : 17: : 18: : 19: : 20: :
* HH:MM to HH:MM
Key FeATUres IN VersIoN 5.1• Guard Tour features: Allows check point validation using card readers, input points (Motion sensors, key
switches, or push buttons) or data collectors.• Asset Management, find quickly who is in possession of your assets and for how long.• Biometrics integration (CDVI’s DGID/W/US, L-1 model 4G, Sagem and more)• Alarm integration: Arm/disarm an alarm system with a double card swipe• Card Usage/Card Counter options (use a card up to 255 times on a door) • All reports including Time & Attendance reports can be sent automatically by e-mail• Unassign card on period of inactivity (up to 365 days)• New DVR support (see the list on the front page)• Import/export users, cards and all related objects• Manually control doors from event window• New controller standalone functionality a. Activate relay on access granted, extended access (Disabled person) b. Activate relay on door forced open status c. Activate relay on door open too long status d. Relay follow input (keep light open on movement) e. Maintain door locked/unlocked on valid card (classroom application)• Play waves on alarm from the administration console• Additional filters in Locator• Now support DNS in the controller properties• Added French support in WavePlayer• Parking group: Reset parking count• SAP import for users/cards• When User/Visitor status is changed, it is now reflected on the cards• Support TELACCESS• Support DGLM magnetic stripe reader• Pro-Report features: a. New short Time & Attendance report. b. Paid Break option c. Manual punch option d. New buttons in the punch management dialog (Add, Delete, Modify and etc.). e. New usage billing report f. New access report type (access granted only) g. New option in Tracker Preferences (show valid users only)
INTEGRATED ACCESS CONTROL
sITe CoNFIgUrATIoN QUICK Form
imPortant --- imPortant Please note that Centaur 5.1 version is compatible with Centaur 5.0 Dongles.
Firmware update of CT-V900-A will be necessary to perform new 5.1 features. See details below:R2-C3-98 - Works with Centaur 5.1 and support up to 8,190 cards
R2-G3-98 - Works with Centaur 5.1 + LCD Tracker feature and support up to 4,914 cards
c d v i . c a c d v i . c a
HArDwAre LIsT
Company Name: ________________________
Address: ______________________________
City: __________________________________
State: _________________________________
Zip Code: ______________________________
Name: ________________________________
Title: __________________________________
Tel: ___________________________________
Cell: __________________________________
E-mail: ________________________________
door tyPe
Controlled entry with Free exit Controlled entry and exit
FrontDoor
Employees Door
To next controller
Requestto exit
Requestto exit
To access control server
Entryreader
Doorstrike*
Entryreader
CT-V900Controller
#1
AC
Doorstrike*
* Can be replace by electromagnet
To access control server To next controller
AC
CT-V900-AController
#1
Door contact
Protected Door
Entry reader
Exit readerDoorstrike*
RS-485 Communication bus
* Can be replace by electromagnet
ProduCts Qty
2-door Controller - Ct-V900-a 2-door exPansion module - Ca-a470-a (3 max. per CT-V900-A controller) 12V-7Ah battery (You need 2 per CT-V900-A and 1 per CA-A470-A or CA-A480-A) CdVi150 transformer: 16VAC and 24VAC,150VA (One CDVI150 transformer can supply one CT-V900-A and tree CA-A470-A)
Proximity reader With multiPle ProtoColes built-in
DGLP FN WLC: Multi-Technology Polycarbonate proximity reader
DGLP WLC: Multi-Technology Polycarbonate proximity reader
DGLI F WLC: Multi-Technology Stainless steel proximity reader
DGLI WLC: Multi-Technology Stainless steel proximity reader
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
E-bus Network Jumper settingsEOL= OFF
Bias High/LowA+= HighB-= High
E-bus Network Jumper settingsEOL= OFF
Bias High/LowA+= HighB-= High
E-bus Network Jumper settingsEOL= OFF
Bias High/LowA+= HighB-= High
E-bus Network Jumper settingsEOL= ON
Bias High/LowA+= HighB-= High
E-bus Network Jumper settingsEOL= ON
Bias High/Low JumpersA+= LowB-= Low
START POINTof the RS-485 E-bus network(Furthest module can be up to1220m (4000ft) from start point)
END POINTof the RS-485E-bus network
CT-V900-A2-Door Controller
CT-V900-A
CA-A480-A CA-A480-A
CA-A470-A CA-A470-A
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 E-BUS NETWORK
At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF
At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH
Addressabledipswitch
Addressabledipswitch
Addressabledipswitch
Addressabledipswitch
c d v i . c a c d v i . c a
ProduCts Quantity 26-bits Wiegand keyPads
galeo/W: 26-bit Wiegand keypad, integrated Piezo/Buzzer, 12Vdc, potted electronics, polished heavy-duty ZAMAK cast alloy (Zinc, Aluminium, Magnesium and Copper)
Proximity Card and badges qBP: leather key ring badge qCS: Clamshell card qISO: Printable card
qBTAG: Blue polycarbonate key ring badge
qPP: Stylish black polycarbonate tear drop badge
rs-485 to rs-232 ConVerter - Ca-a360-a rs-485 to usb/rs-232 ConVerter - Ca-a360-usb rs-232 tCP/iP ConVerter - Ca-ethr-a modem door strike Strike ANSI fail secure: qAR (12VAC/CC) qAR24 (24VCC) Strike ANSI fail safe: qARI (12VCC) qARI24 (24VCC) Strike ANSI continous fail secure: qARCC (12VCC) Strike EFF-EFF fail secure: qAG (12VAC/CC) qAG24 (24VCC) Strike EFF-EFF fail safe: qAGI (12VCC) qAGI24 (24VCC) Strike EFF-EFF continous fail secure: qAGCC (12VCC)
eleCtromagnets V5S: 1100lbs (500kg) holding force, surface mount, 12/24Vdc
V5EI: 1100lbs (500kg) holding force, sliding door applications, flush mount, 12/24Vdc
VSI5R: 1100lbs (500kg) holding force, exterior applications & High-traffic areas, 12/24Vdc
CZ3000: 3000lbs (1500kg) holding force, self-Aligning, 12/24Vdc
Pull station loCk Control module - Ca-a110-P door ContaCt qFlush mount qSurface mount
reQuest to exit Motion detector
BPEST: Touch-to-Exit button
BEI: Stainless steel touch-sensitive handle
POI: Touch-sensitive electronics built-in in the handle, 14” x 2” (39.5cm x 5cm)
EST: Transforms any metallic surface into a request-to-exit device
rs-485 netWork hub - Ca-a370-P qPieZo: q sirene: biometriC Finger Print reader (dgid/W) other:
CT-V900-A2-Door Controller
PO
SIT
ION
GNDTX
B-
+12V
RXGND
A+GND
RE
CE
IVE
TRA
NS
MIT
PO
WE
R
CA
-A36
0-A
Controller Network Jumper settingsEOL= ON
Bias High/Low JumpersA+= LowB-= Low
Controller Network Jumper settingsEOL= OFF
Bias High/Low JumpersA+= HighB-= High
Controller Network Jumper settingsEOL= OFF
Bias High/Low JumpersA+= HighB-= High
Controller Network Jumper settingsEOL= ON
Bias High/Low JumpersA+= HighB-= High
START POINTof the RS-485 controller network.(Furthest modules can be up to 1220m (4000ft) from start point)
END POINTof the RS-485 controller network
CT-V900-A
CT-V900-A
CT-V900-A2-Door Controller
CT-V900-A
CT-V900-A2-Door Controller
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
JUMPER AND ADDRESSABLE DIPSWITCH SETTINGS:EXAMPLE OF RS-485 CONTROLLER NETWORK USING A
CA-A360-A CONVERTER
RS-2327.6m (25ft) max.
Since the converter is now the closest to the server, it is the START POINT.
The converter’s EOL jumper is ON by default and its HIGH/LOW bias jumpers are LOW by default.
Addressable dipswitch
Addressable dipswitch
Addressable dipswitch
7.6m (25ft) max.
HArDwAre LIsT
c d v i . c a c d v i . c a
Project: _______________________________ Door Name:_______________________
Door contact � Surface � Flush
� Electromagnet� 24V � 12V
� Door Strike � 24V � 12V� Fail Safe � Fail Secure
REQUEST-TO-EXIT (REX)� Motion Detector� Pull Station� Push Button� Push Bar/Crash Bar
READING DEVICE (ENTRY)� Reader Technology:_______________� Keypad Technology:_______________
READING DEVICE (EXIT)� Reader Technology:_______________� Keypad Technology:_______________
� Fixed Door
Electromagnet �24V � 12V �
Door contact � Surface � Flush
Fixed Door �
DOUBLE-DOOR OPTION
door typeq Access (Most common setting)q Elevatorq Entry Anti-passback (1 CT-V900-A only, 8 readers)q Exit Anti-passback (1 CT-V900-A only, 8 readers)q Global Entry Anti-passback (multiple doors)q Global Exit Anti-passback (multiple doors)q Parking Global Entry Anti-passbackq Parking Global Exit Anti-passbackq Two Card Rule
optionsq Unlock on late open (Ignore the unlock schedule until the first person arrives) q Time and attendanceq Sign-Out reader (Visitor)
unlock schedule (optional)Schedule time (HH:MM): __________________
Days: S M T W T F S qqqqqqq
interlock (man-trap)With door (input): _________________________
door Programming
CT-V900-A Door HArDwAre
liteCs-aC-lite
standardCs-aC-std
ProfessionalCs-aC-Pro*
enterpriseCs-aC-ent*
Free**
starter PaCk
sites 1 64 64 64 1
serial Ports 1 1 1 4 4
dial up connection Yes Yes Yes Yes Yes
tCP/iP connection Yes Yes Yes Yes Yes
Cards 512 2,048 per site(131,072 max.)
8,196 per site(524,544 max.)
16,384 per site(1,048,576 max.) 512
Controllers 16 32 per site(2,048 max.)
64 per site(4,096 max.)
256 per site(16,384 max.) 1
doors 16 128 per site(8,192 max.)
512 per site(32,768 max.)
2048 per site(131,072 max.) 8
elevator Control - Yes Yes Yes Yes
elevator Cabs - 64 per site(4,096 max.)
128 per site(8,192 max.)
512 per site(32,768 max.) 2
Floors per cab - 64 64 64 64
Floor groups - 128 per site(8,192 max.)
128 per site(8,192 max.)
128 per site(8,192 max.) 128
dVr module - Yes Yes Yes Yes
Visitor management - Yes Yes Yes Yes
Parking management - Yes Yes Yes Yes
guard tour - Yes Yes Yes Yes
asset management - Yes Yes Yes Yes
* Comes with a workstation license New ** Free from our web site, www.cdvi.ca Security dongle not required
INTEGRATED ACCESS CONTROL Version 5.1
Workstation license (Cs-WsliC):Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console and all software modules.
enhanced security dongle. Previous dongle not supported by Centaur V5.0 and 5.1
every Centaur edition includes a Centaur server with an administration console plusall these software modules:Pro-report with tracker: On demand, scheduled or customized reportsFrontView: Live interactive floor plansFrontguard: Display real-time visual authenticationFrontdesk: Create, modify, delete and print cards, include Photo-IDlocator: Monitor real-time location of each card holderWavePlayer: Play a sound on any system event
Programmable outPuts
reader 1 reader 2out 1(Default: Green LED)
out 3(Default: Green LED)
out 2(Default: Red LED)
out 4(Default: Red LED)
out 5(Default: Buzzer)
out 6(Default: Buzzer)
Zone inPuts
Without atZ (Zone doubling) With atZ (Zone doubling)Z1Default:Contact door 1
Z2
Z3Default:REX door 1
Z4
Z5 Z6
Z7 Z8
Z9Default:Contact door 2
Z10
Z11Default:REX door 2
Z12
Z13 Z14
Z15 Z16
relaysRelay 1(Onboard)
Relay 2(Onboard)
adding one relay expansion adding a second relay expansion
Relay 3 Relay 10
Relay 4 Relay 11
Relay 5 Relay 12
Relay 6 Relay 13
Relay 7 Relay 14
Relay 8 Relay 15
Relay 9 Relay 16
c d v i . c a
CT-V900-A Door HArDwAre
manufacturing access Control since 1985
Improvements and built-in features:Centaur improvements:• Automaticallye-mailscheduledreports
• CardUsage/CardCounteroptions (useacardupto255timesonadoor)
• Alarmintegration:arming/disarmingan alarmpanelondualbadge(keyswitchinput)
Visitor ManagementCentaurVisitorManagementwillallowyoutose-curelycontrolthecomingsandgoingsofallvisitors.
Parking ManagementTheCentaurParkingManagementallowsyoutoquicklyseehowmanyparkingplacesareused,bywhichuserandhowmanyparkingspacesareavailableinrealtime.
LocatorMonitorthelocation(inside/outside)ofeachcardholderinreal-time.View/Printreportswithaclickofabutton.Obtaindetailedcardholderinformationwithadouble-clickofthemousebutton.Excellentformuster-pointapplications.
Print or e-mail reports of your activitiesTracktheaccessesofaspecificemployee,verifywhoaccessedaspecificdoorataprecisedateandtimeorcalculatehowmanyhoursofovertimeyouwillpay.Centaurreportwizardallowsyoutocreateyourownreportseasily.
Live Interactive Floor Plans • Createorimportupto512floorplans• Fulllibraryoficons(orcreateyourown)• Event-basedtrigger-actions
Centaur video module (DVR) lets you playback up to 60 seconds before and after a specific event. It also lets you capture a video image (frame) during the playback or live camera viewing in jpeg format.
In Constant Evolution
to fulfill your needs
in access control
New Version 5.1
New features in CeNTAUr Version 5.1:Guard Tour FeatureLive interactive guard tour allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. Includes live alarms for time violations and intuitive exception reports.
Asset Management FeatureWhybuysomethingthatyoualreadyhave?Keeptrackofyourassetsandsavetimeandmoney.Findquicklywhoisinpossessionofyourassets.Areportcanbegeneratedandsentautomaticallyviaemail.
Biometric IntegrationCentaurisapowerfulsolutionforareasrequiringenhancedsecuritybyauthenticatingfingerprints.Capturing,managingandtransferringbiometricdataisnoweffortlesswithworld-renownedfingerprintreaderssuchasCDVI’sDGID/W/US,L-1(model4G),Sagemandmore.
CeNTAUr 5.1 now supports the followingDVr manufacturers:
• Capture• Dahua• Dedicated Micros• Digiop• Digital WatchDog• Eneo• Everfocus• HIK Vision• Infinova• Microcom• Milestone• NUUO• Samsung• Sphere• ViewGate• Vivotek IP Camera• Vivotek
c d v i . c a c d v i . c a
INTEGRATED ACCESS CONTROL
e-bus exPansion module CaPaCity 2-Door Expansion Module (CA-A470-A) 3 Relay Expansion Module (CA-A460-P) 2 Elevator Controller (CA-A480-A) 8 LCD Keypad (CK-TRAK-L) 8
eQuiPment Wire tyPe siZe max. lengthCard reader (1 LED or 1 LED & Buzzer)
and Wiegand keypad 6 conductors, stranded, shielded (foil),
drain conductor, Belden: 5304FE 18AWG 150m (500ft.)
Card reader (2 LEDs & Buzzer) 8 conductors, stranded, shielded (foil),drain conductor, Belden: 5306FE 18AWG 150m (500ft.)
Zone input 4 conductors, copper (JKT) 22AWG 600m (2000ft.)
Door strike & AC transformer for controller 2 conductors, solid copper 18AWG 150m (500ft.), AC transformer: 8m (25ft.)
RS-485 bus Ethernet CAT 5e, 4 pairs 24AWG 1220m (4000ft.)
Z1: 1K Ohm Z2: 2.2K Ohm
EOL1K Ohm
Optional Loop Supervision
MagneticDoor Contact
Request-to-Exit Button (EXIT-BLP)
+-
+-
+
-
+
-
+-
+-
+
-
!Always consult the regulatory agency in your area for existing regulations regarding doors designated as emergency exits.
!Reader wiring may differ from diagram. Please consult your documentation for details.
Lock Control Module (optional)
CA-A110-P
GND
GND
A1+
B1- GND
GND
A2+
B2-
CoNtrollEr iNputs (up to 16 pEr CoNtrollEr)
+-Power
Supply
+-Power
Supply
Connect directly to controller lock terminals
ElECtroMagNEtiC loCk or door strikE optioN
alarM souNdEr
2-door CoNtrollEr
Ct-V900-a
R1/DO
GND
R1/D112VOUT1OUT2OUT5
GREEN
BLACK
WHITEREDYELLOW (green LED)ORANGE (red LED)BROWN (buzzer)
Blue (Clock) Not applicable with Centaur System
R2/DO
GND
R2/D112VOUT3OUT4OUT6
DO
-
D1+V (green LED)R (red LED)B (buzzer)
H (Clock) Not applicable with Centaur System
Connect earth terminal toa certified earth ground
Transformater CDVI15024 Vac, 75VAAlso includes an output of16 VAC (75 VA) that can power up to 32-door expansion modules CA-A470-A
2 batteries(12V, 7AH)
connected in series for 24V backup
Tamper Switch N.C. Contact
To next controller of a site.
module netWork(e-bus rs-485)Furthest module can be installed up to 1220M (4000ft) away from the CT-V900-A controller
PolycarbonateProximityreaderdglP Fn WlC26
stainless steelProximity reader
dgli WlC26
CoNtrollEr NEtwork(rs-485)
Fire alarm contact for Lock1 & Lock2
PolycarbonateProximityreaderdgl
ISO - Thin card for printing
CS - Standard clamshell card
ISO - ISO - ISO - ISO -
CS - CS - Standard clamshell cardStandard clamshell cardCS - CS - Standard clamshell cardStandard clamshell card