cummins fault code 2012-01-23_225828_fc364

2
: Overview Circuit Description This circuit is used to communicate fueling, timing, and pump status messages between the ECM and pump controller. If this link is lost, the pump will run in a backup mode based on the idle signal (pin 4). Component Location The datalink is located within the ECM and fuel pump control module. Shop Talk The datalink is used to communicate fueling and timing commands, as well as pump status messages. If the datalink is lost, the pump will run in backup mode based on idle signal (pin 4 at VP44 connector). This fault code will be active if the VP44 power supply is inadequate. When troubleshooting for this fault, suspect that one or a combination of the following can be the cause: The ECM, fuel pump, or wiring harness/fuses/relay. FAULT CODE 364 Electronic Control Module (ECM) to Pump Communications Error CODE REASON EFFECT Fault Code: 364 PID: P1689, S233 SPN: 1077 FMI: 9 LAMP: Yellow SRT: No communications or invalid data transfer rate detected on datalink between the ECM and VP44 fuel pump control module at pins 4 and 13 of the engine harness. Engine power derate, low power, two- speed engine operation. VP44 Fuel Pump Circuit Page 1 of 2 Electronic Control Module (ECM) to Pump Communications Error 23/01/2012 22:34:01

Upload: azharcattt

Post on 11-Nov-2014

572 views

Category:

Documents


29 download

TRANSCRIPT

Page 1: cummins fault code 2012-01-23_225828_fc364

:

Overview

Circuit Description

This circuit is used to communicate fueling, timing, and pump status messages between the ECM and pump controller. If this link is lost, the pump will run in a backup mode based on the idle signal (pin 4).

Component Location

The datalink is located within the ECM and fuel pump control module.

Shop Talk

� The datalink is used to communicate fueling and timing commands, as well as pump status messages. If the datalink is lost, the pump will run in backup mode based on idle signal (pin 4 at VP44 connector).

� This fault code will be active if the VP44 power supply is inadequate. � When troubleshooting for this fault, suspect that one or a combination of the following

can be the cause: The ECM, fuel pump, or wiring harness/fuses/relay.

FAULT CODE 364 Electronic Control Module (ECM) to Pump

Communications Error

CODE REASON EFFECT

Fault Code: 364 PID: P1689, S233 SPN: 1077 FMI: 9 LAMP: Yellow SRT:

No communications or invalid data transfer rate detected on datalink between the ECM and VP44 fuel pump control module at pins 4 and 13 of the engine harness.

Engine power derate, low power, two-speed engine operation.

VP44 Fuel Pump Circuit

Page 1 of 2Electronic Control Module (ECM) to Pump Communications Error

23/01/201222:34:01

Page 2: cummins fault code 2012-01-23_225828_fc364

Refer to Troubleshooting Fault Code t05-364

Last Modified: 29-Jul-2010

Copyright © 2000-2009 Cummins Inc. All rights reserved.

Page 2 of 2Electronic Control Module (ECM) to Pump Communications Error

23/01/201222:34:01