Overview
Circuit Description
This circuit is used to communicate fueling, timing, and pump status messages between the ECM and pump controller. If this link is lost, the pump will run in a backup mode based on the idle signal (pin 4).
Component Location
The datalink is located within the ECM and fuel pump control module.
Shop Talk
� The datalink is used to communicate fueling and timing commands, as well as pump status messages. If the datalink is lost, the pump will run in backup mode based on idle signal (pin 4 at VP44 connector).
� This fault code will be active if the VP44 power supply is inadequate. � When troubleshooting for this fault, suspect that one or a combination of the following
can be the cause: The ECM, fuel pump, or wiring harness/fuses/relay.
FAULT CODE 364 Electronic Control Module (ECM) to Pump
Communications Error
CODE REASON EFFECT
Fault Code: 364 PID: P1689, S233 SPN: 1077 FMI: 9 LAMP: Yellow SRT:
No communications or invalid data transfer rate detected on datalink between the ECM and VP44 fuel pump control module at pins 4 and 13 of the engine harness.
Engine power derate, low power, two-speed engine operation.
VP44 Fuel Pump Circuit
Page 1 of 2Electronic Control Module (ECM) to Pump Communications Error
23/01/201222:34:01
Refer to Troubleshooting Fault Code t05-364