NAMUR PS2-11P-N/SX PS4-11P-N/SX
( DIN - 19234 )
Picture 1 1
Nominal distance 2 mm 4 mm
Operating sensor distance 0 … 1.62 mm 0 … 3.24 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 11 x 11 mm 11 x 11 mm
Supply voltage 7 to 12 Vdc 7 to 12 Vdc
Nominal voltage 8 Vdc ± 5 % 8 Vdc ± 5 %
Ripple 5 % 5 %
Voltage with the sensor activated £ 1 mA £ 1 mA
Voltage with the sensor disabled ³ 3 mA ³ 3 mA
Max. wiring resistance 100 W 100 W
Maximum frequency 800 Hz 400 Hz
Signalling without led without led
Operating temperature - 25 oC to + 100 oC - 25 oC to + 70 oC
Protection rate IP 67 IP 67
Connection 2-wire cable 2-wire cable
Tube length 32 mm 32 mm
Cable options PVC 6 m PVC 6 m
Casing thermoplastic (PBT/ VO) thermoplastic (PBT/ VO)
Cable Color
MR brown
AZ blue
1-4.1
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
Namur DirectCurrent
ØØ1111
3322
F11
NPN PS2-11P-A/SZ PS4-11P-A/SZ
PNP PS2-11P-A2/SZ PS4-11P-A2/SZ
Picture 1 1
Nominal distance 2 mm 4 mm
Operating sensor distance 0 … 1.62 mm 0 … 3.24 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 11 x 11 mm 11 x 11 mm
Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Ripple + 10 % + 10 %
Consumption current < 10 mA < 10 mA
Maximum switching current 200 mA ± 15 % 200 mA ± 15 %
Output protection short-circuit and inversion short-circuit and inversion
Transient Protection 1 kV / 10ms / 10kW 1 kV / 10ms / 10kW
Sensor voltage drop < 2 V < 2 V
Maximum frequency 800 Hz 400 Hz
Signalling back led back led
Operating temperature - 25 °C to + 70 oC - 25 °C to + 70 °C
Protection rate IP 67 IP 67
Connection cable 4 wires cable 4 wires
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Tube length 71 71
Casing thermoplastic (PBT/ VO) thermoplastic (PBT/ VO)
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.2
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
Direct Current4 wires
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
F11
71
NAMUR PS4-16I-N/SX NPN PS4-16I-A/SZ PS5-16P-A/SZ
( DIN - 19234 ) PNP PS4-16I-A2/SZ PS5-16P-A2/SZ
Picture 1 Picture 2 3
Nominal distance 4 mm Nominal distance 4 mm 5 mm
Operating sensor distance 0 … 3. 24 mm Operating sensor distance 0 … 3.24 mm 0 … 4.05 mm
Assembly built-in Assembly built-in built-in
Hysteresis 5 % Hysteresis 5 % 5 %
Repeatability < 0. 01 mm Repeatability < 0.01 mm < 0.01 mm
Standard target 16 x 16 mm Standard target 16 x 16 mm 16 x 16 mm
Supply voltage 7 to 12 Vdc Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Nominal voltage 8 Vdc ± 5 % Ripple ± 10 % ± 10 %
Ripple 5 % Consumption current < 10 mA < 10 mA
Voltage with the sensor activated £ 1 mA Maximum switching current 200 mA ± 15 % 200 mA ± 15 %
Voltage with the sensor disabled ³ 3 mA Output protection short-circuit and inversion short-circuit and inversion
Max. wiring resistance 100 W Transient Protection 1kV/ 10 ms / 10kW 1kV/ 10 ms / 10kW
Maximum frequency 500 Hz Sensor voltage drop £`2V £`2V
Signalling without led Maximum frequency 500 Hz 500 Hz
Operating temperature - 25 oC to + 100 oC Signalling back led back led
Protection rate IP 67 Operating temperature - 25ºC to +70ºC -25º C to + 70ºC
Connection 2-wire cable Protection rate IP 67 IP 67
Tube length 50 mm Connection cable 4 wires cable 4 wires
Cable options PVC 6 m Tube length 50 mm 61 mm
Casing nickelled brass Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing Options nickelled brass thermoplastic (PBT/VO)
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.3
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
F 16
Direct CurrentNamur
SSEEXXTT.. 2222xx44
MM1166xx11
5050
Ø
Ø
1
1
6
6
Ø
Ø
3
3
(
(
6
6
x
x
)
)
2
2
6
6
3
3
3
3
1
1
5
5
L
L
E
E
D
D
61
Direct Current4 wires
F 16
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
Alternating Current2 wires
NA PS4-16I-WA/SY PS5-16P-WA/SY
NF PS4-16I-WF/SY PS5-16P-WF/SY
Picture 1 2
Nominal distance 4 mm 5 mm
Operating sensor distance 0 … 3.24 mm 0 … 4.05 mm
Assembly built-in built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 16 x 16 mm 16 x 16 mm
Supply voltage 20 to 250 Vac 20 to 250 Vac
Maximum switching current 500 mA 500 mA
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Impulse Current 4 A 4 A
Load residual voltage 3 mA 3 mA
Load minimum voltage 5 mA 5 mA
Sensor voltage drop£ 5V < 5 V
Maximum frequency 10 Hz 10 Hz
Signalling back led back led
Operating temperature -25°C to + 70°C - 25 oC to + 70 oC
Protection rate IP 67 IP 67
Connection 2-wire cable 2-wire cable
Tube length 50 mm 61 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass thermoplastic (PBT/ VO)
Cable Color
MR brown
AZ blue
VD / AM grounding
1-4.4
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
2200 aa 225500VVccaa
WWFF
AAZZ((22))
MMRR((11))
WWAAMMRR((33))
AAZZ((44))
2200 aa 225500VVccaa
SSEEXXTT.. 2222xx44
MM1166xx11
LLEEDD
50
ØØ1166
ØØ33((66xx))
22663333
1155
LLEEDD
61
F 16
NA PS5-18P-WA/SY PS8-18P-WA/SY
NF PS5-18P-WF/SY PS8-18P-WF/SY
Picture 1 2
Nominal distance 5 mm 8 mm
Operating sensor distance 0 … 4.05 mm 0 … 6.48 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 18 x 18 mm 24 x 24 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60Hz)
Maximum switching current 500 mA 500 mA
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Impulse Current 4 A 4 A
Load residual voltage 3 mA 3 mA
Load minimum voltage 5 mA 5 mA
Sensor voltage drop£ 5 V £ 5 V
Maximum frequency 10 Hz 10 Hz
Signalling back led back led
Operating temperature - 25 oC to + 70 oC - 25 oC to + 70 oC
Protection rate IP 67 IP 67
Connection 2-wire cable 2-wire cable
Tube length 61 mm 61 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing thermoplastic (PBT/ VO) thermoplastic (PBT/ VO)
Cable Color
MR brown
AZ blue
1-4.5
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
Alternating Current2 wires
Ø18
WWAAMMRR((33))
AAZZ((44))
2200 aa 225500VVccaa
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
W
W
F
F
A
A
Z
Z
(
(
2
2
)
)
M
M
R
R
(
(
1
1
)
)
Ø
Ø
1
1
8
8
Ø
Ø
3
3
(
(
6
6
x
x
)
)
3
3
3
3
2
2
6
6
1
1
5
5
L
L
E
E
D
D
61
NPN PS15-32P-A/SZ NAMUR PS15-32P-N/SX
PNP PS15-32P-A2/SZ (DIN - 19234)
Picture 3 Picture 2
Nominal distance 15 mm Nominal distance 15 mm
Operating sensor distance 0 … 12.15 mm Operating sensor distance 0 … 12.15 mm
Assembly not built-in Assembly not built-in
Hysteresis 5 % Hysteresis 5 %
Repeatability < 0.01 mm Repeatability < 0.01 mm
Standard target 45 x 45 mm Standard target 45 x 45 mm
Supply voltage 10 to 30 Vdc Supply voltage 7 to 12 Vdc
Ripple ± 10 % Nominal voltage 8 Vdc ± 5%
Consumption current < 10 mA Ripple 5 %
Maximum switching current 200 mA ± 15 % Voltage with the sensor activated £ 1 mA
Output protection short-circuit and inversion Voltage with the sensor disabled ³ 3 mA
Transient Protection 1 kV / 10ms / 10kW Max. wiring resistance 100 W
Sensor voltage drop £ 2 V Maximum frequency 100 Hz
Maximum frequency 100 Hz Signalling without led
Signalling back led Operating temperature - 25º C to + 100 º C
Operating temperature - 25 oC to + 70 oC Protection rate IP 67
Protection rate IP 67 Connection 2-wire cable
Connection cable 4 wires Tube length 107 mm
Tube length 107 mm Cable options PVC 6 m
Cable options PVC 6 m or polyurethane 2 m Casing thermoplastic (PBT/VO)
Casing Options thermoplastic (PBT/ VO)
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.6
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
SSEEXXTT.. 2222xx44
MM1166xx11
50 107
89
F 32
Direct Current4 wires
F 32
Direct Current4 wires
NA PS15-32P-W3A/SY PS15-32P-W4/S2X NA PS15-32-WA/SY
NF PS15-32P-W3F/SY NF PS15-32P-WF/SY
Picture 1 2 Picture 3
Nominal distance 15 mm 15 mm Nominal distance 15 mm
Operating sensor distance 0 … 12.15 mm 0 … 12.15 mm Operating sensor distance 0 … 12.15 mm
Assembly not built-in not built-in Assembly not built-in
Hysteresis 5 % 5 % Hysteresis 5 %
Repeatability < 0.01 mm < 0.01 mm Repeatability < 0.01 mm
Standard target 45 x 45 mm 45 x 45 mm Standard target 45 x 45 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz) Supply voltage 20 to 250 Vac
Maximum switching current 500 mA 500 mA Maximum switching current 500 mA
Consumption current £ 10 mA £ 10 mA Transient Protection 1 kV / 10 ms / 10 kW
Impulse Current 4 A 4 A Impulse Current 4 A
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW Load residual voltage 3 mA
Sensor voltage drop £ 1.5 V £ 1.5 V Load minimum voltage 5 mA
Maximum frequency 10 Hz 10 Hz Sensor voltage drop £ 5 V
Signalling back led back led Maximum frequency 10 Hz
Operating temperature - 25 oC to + 70 oC - 25 oC to + 70 oC Signalling back led
Protection rate IP 67 IP 67 Operating temperature - 25º C to + 70º C
Connection cable 3 wires cable 4 wires Protection rate IP 67
Tube length 107 mm 107 mm Connection 2-wire cable
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m Tube length 107 mm
Casing thermoplastic (PBT/ VO) thermoplastic (PBT/ VO) Cable options PVC 6 m or polyurethane 2 m
Casing thermoplastic (PBT/VO)
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.7
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
Alternating Current3 wires / 4 wires
F 32
Alternating Current2 wires
WWAAMMRR((33))
AAZZ((44))
2200 aa 225500VVccaa
W
W
3
3
F
F
N
N
F
F
M
M
R
R
(
(
1
1
)
)
P
P
R
R
(
(
4
4
)
)
A
A
Z
Z
(
(
3
3
)
)
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
W
W
3
3
A
A
M
M
R
R
(
(
1
1
)
)
A
A
Z
Z
(
(
3
3
)
)
P
P
R
R
(
(
4
4
)
)
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
A
A
P
P
R
R
(
(
4
4
)
)
B
B
R
R
(
(
2
2
)
)
A
A
Z
Z
(
(
3
3
)
)
M
M
R
R
(
(
1
1
)
)
9
9
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
-
-
+
+
W
W
4
4
107
89
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
W
W
F
F
A
A
Z
Z
(
(
2
2
)
)
M
M
R
R
(
(
1
1
)
)
F 32
NAMUR PS2-14I-N/SX PS4-14I-N/SX
( DIN - 19234 )
Picture 1 2
Nominal distance 2 mm 4 mm
Operating sensor distance 0 … 1.62 mm 0 … 3.24 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 14 x 14 mm 14 x 14 mm
Supply voltage 7 to 12 Vdc 7 to 12 Vdc
Nominal voltage 8 Vdc ± 5 % 8 Vdc ± 5 %
Ripple + 5 % + 5 %
Voltage with the sensor activated £ 1 mA £ 1 mA
Voltage with the sensor disabled ³ 3 mA ³ 3 mA
Max. wiring resistance 100 W 100 W
Maximum frequency 800 Hz 400 Hz
Signalling without led without led
Operating temperature - 25 oC to + 100 oC - 25 oC to + 100 oC
Protection rate IP 67 IP 67
Connection 2-wire cable 2-wire cable
Tube length 32 mm 32 mm
Cable options PVC 6 m PVC 6 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
1-4.8
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
M14
Direct CurrentNamur
SSEEXXTT.. 1199xx44MM
1144xx11
32 32
NPN PS2-14I-A/SZ PS4-14I-A/SZ
PNP PS2-14I-A2/SZ PS4-14I-A2/SZ
Picture 1 2
Nominal distance 2 mm 4 mm
Operating sensor distance 0 … 1.62 0 … 3.24 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 14 x 14 mm 14 x 14 mm
Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Ripple ± 10 % ± 10 %
Consumption current < 10 mA < 10 mA
Maximum switching current 200 mA ± 15 % 200 mA ± 15 %
Output protection short-circuit and inversion short-circuit and inversion
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 2 V £ 2 V
Maximum frequency 800 Hz 200 Hz
Signalling back led back led
Operating temperature - 25°C to + 70°C - 25 oC to + 70 oC
Protection rate IP 67 IP 67
Connection cable 4 wires cable 4 wires
Tube length 51 mm 51 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.9
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
M14
Direct Current4 wires
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
M
M
1
1
4
4
x
x
1
1
S
S
E
E
X
X
T
T
.
.
1
1
9
9
x
x
4
4
L
L
E
E
D
D
51
32
NPN PS6-20I-A/SZ NA PS6-20I-WA/SY
PNP PS6-20I-A2/SZ NF PS6-20I-WF/SY
Picture 1 Picture 2
Nominal distance 6 mm Nominal distance 6 mm
Operating sensor distance 0 … 4.86 mm Operating sensor distance 0 … 4.86 mm
Assembly built-in Assembly built-in
Hysteresis 5 % Hysteresis 5%
Repeatability < 0.01 mm Repeatability < 0.01 mm
Standard target 20 x 20 mm Standard target 20 x 20 mm
Supply voltage 10 to 30 Vdc Supply voltage 20 to 250 Vac (50 - 60 Hz)
Ripple ± 10 % Max. switching currento 500 mA
Consumption current < 10 mA Transient Protection 1 kV / 10 ms / 10W
Maximum switching current 200 mA ±15 % Impulse Current 4 A
Output protection short-circuit and inversion Load residual voltage 3 mA
Transient Protection 1 kV / 10 ms / 10kW Load minimum voltage 5 mA
Sensor voltage drop £ 2 V Sensor voltage drop £ 5 V
Maximum frequency 200 Hz Maximum frequency 10 Hz
Signalling back led Signalling back led
Operating temperature - 25 ºC to + 70 ºC Operating temperature - 25ºC to +70ºC
Protection rate IP 67 Protection rate IP 67
Connection cable Connection cable
Tube length 50 mm Tube length 50 mm
Cable options PVC 6 m or polyurethane 2 m Cable options PVC 6 m or polyurethane 2 m
Casing nickelled brass Casing nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.10
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
Corrente Continua4 wires
M20
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
S
S
E
E
X
X
T
T
.
.
2
2
5
5
x
x
4
4
M
M
2
2
0
0
x
x
1
1
L
L
E
E
D
D
50
Alternating Current2 wires
M20
SSEEXXTT.. 2255xx44
MM2200xx11
LLEEDD
50
NPN PS8-22I-A/SZ NA PS8-22I-WA/SY
PNP PS8-22I-A2/SZ NF PS8-22I-WF/SY
Picture 1 Picture 2
Nominal distance 6 mm Nominal distance 8 mm
Operating sensor distance 0 … 6.48 mm Operating sensor distance 0 … 6.48 mm
Assembly built-in Assembly built-in
Hysteresis 5 % Hysteresis 5 %
Repeatability < 0.01 mm Repeatability < 0.01 mm
Standard target 20 x 20 mm Standard target 24 x 24 mm
Supply voltage 10 to 30 Vdc Supply voltage 20 to 250 Vac (50 - 60 Hz)
Ripple ± 10% Max. switching current 500 mA
Consumption current < 10 mA Transient Protection 1 kV / 10 ms / 10kW
Maximum switching current 200 mA ±15% Impulse Current 4 A
Output protection curto-circuto e inversão Residual voltage on load 3 mA
Protection against transient 1 kV/ 10 ms / 10 W Load minimum voltage 5 mA
Sensor voltage drop £ 2 V Sensor voltage drop £ 5 V
Maximum frequency 200 Hz Maximum frequency 10 Hz
Signalling back led Signalling back led
Operating temperature - 25ºC to + 70 ºC Operating temperature - 25 ºC to + 70 ºC
Protection rate IP 67 Grau de proteção IP 67
Connection cable Connection cable
Tube length 50 mm Tube length 50 mm
Cable options PVC 6 m or polyurethane 2 m Cable options PVC 6 m or polyurethane 2 m
Casing nickelled brass Casing nickelled brass
Cable Color
MR brown
AZ blue
VD / AM grounding
1-4.11
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
Alternating Current2 wires
M22
SSEEXXTT.. 2255xx44
MM2200xx11
LLEEDD
50
M22x1,5
M22x1,5
ØØ1199
22
SSEEXXTT.. 2299xx55
LLEEDD
50
S
S
E
E
X
X
T
T
.
.
2
2
2
2
x
x
4
4
M
M
1
1
6
6
x
x
1
1
L
L
E
E
D
D
50
Ø
Ø
M51x1,5
M51x1,5
SEXT. 64x7
SEXT. 64x7
1111
6565
8787
ØØ1313
ØØ4848
2222
Alternating Current2 wires
M22
NA PS6-20I-W3A/SY PS8-22I-W3A/SY
NF PS6-20I-W3F/SY PS8-22I-W3F/SY
Picture 1 2
Nominal distance 6 mm 8 mm
Operating sensor distance 0 … 4.86 mm 0 … 6.48 mm
Assembly built-in built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 20 x 20 mm 24 x 24 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA
Consumption current £ 10 mA £ 10 mA
Impulse Current 4 A 4 A
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 1.5 V £ 1.5 V
Maximum frequency 10Hz 10 Hz
Signalling back led back led
Operating temperature - 25 oC to + 70 oC - 25 oC to + 70 oC
Protection rate IP 67 IP 67
Connection cable 3 wires cable 3 wires
Tube length 50 mm 50 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
VD / AM grounding
1-4.12
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
Alternating Current3 wires
M20 / M22
WW33AA
VVDD//AAMM((55))
MMRR((11))
AAZZ((33))
PPRR((44))2200 aa 225500VVccaa
NNAA
S
S
E
E
X
X
T
T
.
.
2
2
5
5
x
x
4
4
M
M
2
2
0
0
x
x
1
1
L
L
E
E
D
D
50
M22x1,5
M22x1,5
ØØ1199
22
SSEEXXTT.. 2299xx55
LLEEDD
50
NPN PS10-25I-A/SZ PS12-25I-A/SZ
PNP PS10-25I-A2/SZ PS12-25I-A2/SZ
Picture 1 2
Nominal distance 10 mm 12 mm
Operating sensor distance 0 … 8.1 mm 0 … 9.72 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 25 x 25 mm 36 x 36 mm
Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Ripple £ 10 % £ 10 %
Consumption current < 10 mA < 10 mA
Max. switching current 200 mA ± 15 % 200 mA ± 15 %
Output protection short-circuit and inversion short-circuit and inversion
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 2 V £ 2V
Maximum frequency 300 Hz 100 Hz
Signalling back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 50 mm 50 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.13
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
MM2255xx11
SSEEXXTT.. 3322xx55
LLEEDD
50
1122
MM2255xx11
ØØ2244
SSEEXXTT.. 3322xx55
LLEEDD
50
Direct Current4 wires
M25
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
NA PS10-25I-WA/SY PS12-25I-WA/SY
NF PS10-25I-WF/SY PS12-25I-WF/SY
Picture 1 2
Nominal distance 10 mm 12 mm
Operating sensor distance 0 … 8.1 mm 0 … 9.72 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 25 x 25 mm 36 x 36 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Impulse Current 4 A 4 A
Residual voltage on load 3 mA 3 mA
Minimum voltage on load 5 mA 5 mA
Sensor voltage drop< 5 V < 5 V
Maximum frequency 10 Hz 10 Hz
Signalling back led back led
Operating temperature - 25 °C to + 70°C - 25°C to + 70°C
Protection rate IP 67 IP 67
Connection cable cable
Tube length 50 mm 50 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
VD / AM grounding
1-4.14
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
MM2255xx11
SSEEXXTT.. 3322xx55
LLEEDD
50
1122
MM2255xx11
ØØ2244
SSEEXXTT.. 3322xx55
LLEEDD
50
Alternating Current2 wires
M25
2200 aa 225500VVccaa
NNFF
WWFF
VVDD//AAMM((55))
AAZZ((22))
MMRR((11))
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
F
F
W
W
F
F
V
V
D
D
/
/
A
A
M
M
(
(
5
5
)
)
A
A
Z
Z
(
(
2
2
)
)
M
M
R
R
(
(
1
1
)
)
NA PS10-25I-W3A/SY PS12-25I-W3A/SY PS10-25H-W4/S2X PS12-25H-W4/S2X
NF PS10-25I-W3F/SY PS12-25I-W3F/SY
Picture 1 2 1 2
Nominal distance 10 mm 12 mm 10 mm 12 mm
Operating sensor distance 0 … 8.1 mm 0 … 9.72 mm 0 … 8.1 mm 0 … 9.72 mm
Assembly built-in not built-in built-in not built-in
Hysteresis 5 % 5 % 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm
Standard target 25 x 25 mm 36 x 36 mm 25 x 25 mm 36 x 36 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA 500 mA 500 mA
Consumption current £10 mA £10 mA £10 mA £10 mA
Impulse Current 4 A 4 A 4 A 4 A
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 1.5 V £ 1.5 V £ 1.5 V £ 1.5 V
Maximum frequency 10 Hz 10 Hz 10 Hz 10 Hz
Signalling back led back led back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67 IP 67 IP 67
Connection cable 3 wires cable 3 wires cable 4 wires cable 4 wires
Tube length 50 mm 50 mm 50 mm 50 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
VD / AM grounding
1-4.15
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
Alternating Current3 wires / 4 wires
M25
PPRR((44))
BBRR((22))
AAZZ((33))
MMRR((11))
9900 aa 225500VVccaa
--
++WW44
1
1
2
2
M
M
2
2
5
5
x
x
1
1
Ø
Ø
2
2
4
4
S
S
E
E
X
X
T
T
.
.
3
3
2
2
x
x
5
5
L
L
E
E
D
D
50
M
M
2
2
5
5
x
x
1
1
S
S
E
E
X
X
T
T
.
.
3
3
2
2
x
x
5
5
L
L
E
E
D
D
50
W
W
3
3
A
A
V
V
D
D
/
/
A
A
M
M
(
(
5
5
)
)
M
M
R
R
(
(
1
1
)
)
A
A
Z
Z
(
(
3
3
)
)
P
P
R
R
(
(
4
4
)
)
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
A
A
NAMUR PS12-36IG-N/SX PS17-36IG-N/SX
( DIN - 19234 )
Picture 1 2
Nominal distance 12 mm 17 mm
Operating sensor distance 0 … 9.72 mm 0 … 13.77 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 36 x 36 mm 51 x 51 mm
Supply voltage 7 to 12 Vdc 7 to 12 Vdc
Nominal voltage 8 Vdc ± 5 % 8 Vdc ± 5 %
Ripple 5 % 5 %
Voltage with the sensor activated £ 1 mA £ 1 mA
Voltage with the sensor disabled ³ 3 mA ³ 3 mA
Max. wiring resistance 100 W 100 W
Maximum frequency 100 Hz 100 Hz
Signalling without led without led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 50 mm 75 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
1-4.16
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
M36
Direct CurrentNamur
5050
SEXT. 42x5
SEXT. 42x5
M36x1,5
M36x1,5
M36x1,5
M36x1,5
ØØ
SEXT. 42x5
SEXT. 42x5
3232
1313
1515
5151
7575
ØØ
1111ØØ
NPN PS12-36I-A/SZ PS17-36I-A/SZ
PNP PS12-36I-A2/SZ PS17-36I-A2/SZ
Picture 1 2
Nominal distance 12 mm 17 mm
Operating sensor distance 0 … 9.72 mm 0 … 13.77 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 36 x 36 mm 51 x 51 mm
Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Ripple ± 10 % ± 10%
Consumption current < 10 mA < 10 mA
Max. switching currento 200 mA ± 15 % 200 mA ± 15 %
Output protection short-circuit and inversion short-circuit and inversion
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 2 V £ 2 V
Maximum frequency 100 Hz 100 Hz
Signalling back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 50 mm 50 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.17
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
M36
Direct Current4 wires
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
LEDLED
5050
SEXT. 42x5
SEXT. 42x5
M36x1,5
M36x1,5
Ø
Ø
3232
LEDLED
5050
SEXT. 42x5
SEXT. 42x5M
36x1,5
M36x1,5
1818
NA PS12-36I-WA/SY PS17-36I-WA/SY
NF PS12-36I-WF/SY PS17-36I-WF/SY
Picture 1 2
Nominal distance 12 mm 17 mm
Operating sensor distance 0 … 9.72 mm 0 … 13.77 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 36 x 36 mm 51 x 51 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA
Consumption current < 10 mA < 10 mA
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Impulse Current 4 A 4 A
Residual voltage on load 3 mA 3 mA
Load minimum voltage 5 mA 5 mA
Sensor voltage drop £ 5 V £ 5 V
Maximum frequency 10 Hz 10 Hz
Signalling back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
VD / AM grounding
1-4.18
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
M36
Alternating Current2 wires
WWAAMMRR((33))
AAZZ((44))
VVDD//AAMM((55))
2200 aa 225500VVccaa
NNAA
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
F
F
W
W
F
F
V
V
D
D
/
/
A
A
M
M
(
(
5
5
)
)
A
A
Z
Z
(
(
2
2
)
)
M
M
R
R
(
(
1
1
)
)
LEDLED
5050
SEXT. 42x5
SEXT. 42x5
M36x1,5
M36x1,5
Ø
Ø
3232
LEDLED
5050
SEXT. 42x5
SEXT. 42x5M
36x1,5
M36x1,5
1818
NA PS12-36I-W3A/SY PS17-36I-W3A/SY PS12-36H-W4/S2X PS17-36H-W4/S2X
NF PS12-36I-W3F/SY PS17-36I-W3F/SY
Picture 1 2 3 4
Nominal distance 12 mm 17 mm 12 mm 17 mm
Operating sensor distance 0 … 9.72 mm 0 … 13.77 mm 0 … 9.72 mm 0 … 13.77 mm
Assembly built-in not built-in built-in not built-in
Hysteresis 5 % 5 % 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm
Standard target 36 x 36 mm 51 x 51 mm 36 x 36 mm 51 x 51 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA 500 mA 500 mA
Consumption current < 10 mA < 10 mA < 10 mA < 10 mA
Impulse Current 4 A 4 A 4 A 4 A
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop£ 1.5 V £ 1.5 V £ 1.5 V £ 1.5 V
Maximum frequency 10 Hz 10 Hz 10 Hz 10 Hz
Signalling back led back led back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67 IP67 IP67
Connection cable 3 wires cable 3 wires cable 4 wires cable 4 wires
Tube length 50 mm 50 mm 79 mm 79 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
VD / AM grounding
1-4.19
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
M36
Alternating Current3 wires / 4 wires
PPRR((44))
BBRR((22))
AAZZ((33))
MMRR((11))
9900 aa 225500VVccaa
--
++WW44W
W
3
3
A
A
V
V
D
D
/
/
A
A
M
M
(
(
5
5
)
)
M
M
R
R
(
(
1
1
)
)
A
A
Z
Z
(
(
3
3
)
)
P
P
R
R
(
(
4
4
)
)
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
A
A
Ø
Ø
3232
LEDLED
5050
SEXT. 42x5
SEXT. 42x5M
36x1,5
M36x1,5
1818
LEDLED
5050
SEXT. 42x5
SEXT. 42x5
M36x1,5
M36x1,5
NAMUR PS18-51G-N/SX PS25-51G-N/SX
( DIN - 19234 )
Picture 1 2
Nominal distance 18 mm 25 mm
Operating sensor distance 0 … 14.58 mm 0 … 20.25 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 51 x 51 mm 75 x 75 mm
Supply voltage 7 to 12 Vdc 7 to 12 Vdc
Nominal voltage 8 Vdc ± 5 % 8 Vdc ± 5 %
Ripple 5 % 5 %
Voltage with the sensor activated £ 1 mA £ 1 mA
Voltage with the sensor disabled ³ 3 mA ³ 3 mA
Max. wiring resistance 100 W 100 W
Maximum frequency 100 Hz 100 Hz
Signalling without led without led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 87 mm 87 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
1-4.20
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
M51
Direct Current Namur
ØØ
M51x1,5
M51x1,5 SEXT. 6
4x7
SEXT. 64x7
1111
6565
8787
ØØ1313Ø
Ø
M51x1,5
M51x1,5
SEXT. 64x7
SEXT. 64x7
1111
6565
8787
ØØ1313
ØØ4848
2222
NPN PS18-51G-A/SZ PS25-51G-A/SZ
PNP PS18-51G-A2/SZ PS25-51G-A2/SZ
Picture 1 2
Nominal distance 18 mm 25 mm
Operating sensor distance 0 … 14.58 mm 0 … 20.25 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 51 x 51 mm 75 x 75 mm
Supply voltage 10 to 30 Vdc 10 to 30 Vdc
Ripple £ 10 % £ 10 %
Consumption current < 10 mA < 10 mA
Maximum switching current 200 mA ± 15 % 200 mA ±15 %
Output protection short-circuit and inversion short-circuit and inversion
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop< 2 V < 2 V
Maximum frequency 100 Hz 100 Hz
Signalling back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 87 mm 87 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
1-4.21
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
M51
Direct Current4 wires
1100 aa 3300VVcccc
MMRR((11))NNPPNN
NA+NFNA+NF
-- AA
BBRR((22))
PPRR((44))
AAZZ((33)) --
++
Ø
Ø
M51x1,5
M51x1,5 SEXT. 6
4x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
Ø
Ø
M51x1,5
M51x1,5
SEXT. 64x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
ØØ4848
2222
NA PS18-51G-WA/SY PS25-51G-WA/SY
NF PS18-51G-WF/SY PS25-51G-WF/SY
Picture 1 2
Nominal distance 18 mm 25 mm
Operating sensor distance 0 … 14.58 mm 0 … 20.25 mm
Assembly built-in not built-in
Hysteresis 5 % 5 %
Repeatability < 0.01 mm < 0.01 mm
Standard target 51 x 51 mm 75 x 75 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz)
Max. consumption current 500 mA 500 mA
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Impulse Current 4 A 4 A
Load residual voltage 3 mA 3 mA
Load minimum voltage 5 mA 5 mA
Sensor voltage drop£ 5 V £ 5 V
Maximum frequency 10 Hz 10 Hz
Signalling back led back led
Operating temperature - 25 ºC to + 70 ºC - 25 ºC to + 70 ºC
Protection rate IP 67 IP 67
Connection cable cable
Tube length 87 mm 87 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
VD / AM grounding
1-4.22
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Mechanical
Inductive Proximity Sensors
M51
2200 aa 225500VVccaa
NNFF
WWFF
VVDD//AAMM((55))
AAZZ((22))
MMRR((11))
Ø
Ø
M51x1,5
M51x1,5 SEXT. 6
4x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
Ø
Ø
M51x1,5
M51x1,5
SEXT. 64x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
ØØ4848
2222
W
W
A
A
M
M
R
R
(
(
3
3
)
)
A
A
Z
Z
(
(
4
4
)
)
V
V
D
D
/
/
A
A
M
M
(
(
5
5
)
)
2
2
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
N
N
A
A
Alternating Current2 wires
NA PS18-51G-W3A/SY PS25-51G-W3A/SY PS18-51G-W4/S2X PS25-51G-W4/S2X
NF PS18-51G-W3F/SY PS25-51G-W3F/SY
Picture 1 2 3 4
Nominal distance 18 mm 25 mm 18 mm 25 mm
Operating sensor distance 0 … 14.58 mm 0 … 20.25 mm 0 … 14.58 mm 0 … 20.25mm
Assembly built-in not built-in built-in not built-in
Hysteresis 5 % 5 % 5% 5%
Repeatability < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm
Standard target 51 x 51mm 75 x 75 mm 51 x 51 mm 75 x 75 mm
Supply voltage 20 to 250 Vac (50 - 60 Hz) 20 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz) 90 to 250 Vac (50 - 60 Hz)
Maximum switching current 500 mA 500 mA 500 mA 500 mA
Consumption current < 10 mA < 10 mA < 10 mA < 10 mA
Impulse Current 4 A 4 A 4 A 4 A
Transient Protection 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW 1 kV / 10 ms / 10kW
Sensor voltage drop £ 1.5 V £ 1.5 V £ 1.5 V £ 1.5 V
Maximum frequency 10 Hz 10 Hz 10 Hz 10 Hz
Signalling back led back led back led back led
Operating temperature - 25 oC to + 70 oC - 25 oC to + 70 oC - 25 oC to + 70 oC - 25 oC to + 70 oC
Protection rate IP 67 IP 67 IP 67 IP 67
Connection cable 3 wires cable 3 wires cable 4 wires cable 4 wires
Tube length 87 mm 87 mm 87 mm 87 mm
Cable options PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m PVC 6 m or polyurethane 2 m
Casing nickelled brass nickelled brass nickelled brass nickelled brass
Cable Color
MR brown
AZ blue
PR black
BR white
VD / AM grounding
1-4.23Rev.A - 11/2013
MechanicalDimensions
COMPLEMENTARY LINE
Output ConfigurationIEC 947-5-2 / IEC 1000-4-2.3.4.5
Inductive Proximity Sensors
M51
Alternating Current 3 wires / 4 wires
WW33AA
VVDD//AAMM((55))
MMRR((11))
AAZZ((33))
PPRR((44))2200 aa 225500VVccaa
NNAA
P
P
R
R
(
(
4
4
)
)
B
B
R
R
(
(
2
2
)
)
A
A
Z
Z
(
(
3
3
)
)
M
M
R
R
(
(
1
1
)
)
9
9
0
0
a
a
2
2
5
5
0
0
V
V
c
c
a
a
-
-
+
+
W
W
4
4
Ø
Ø
M51x1,5
M51x1,5 SEXT. 6
4x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
Ø
Ø
M51x1,5
M51x1,5
SEXT. 64x7
SEXT. 64x7
1111
6565
8787
ØØ1313
LEDLED
ØØ4848
2222