Current Transducer HASS 50..600-S For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). All Data are given with a R L = 10 k Electrical data Primary nominal Primary current Type current rms measuring range I PN (A) I PM (A) 50 ± 150 HASS 50-S 100 ± 300 HASS 100-S 200 ± 600 HASS 200-S 300 ± 900 HASS 300-S 400 ± 900 HASS 400-S 500 ± 900 HASS 500-S 600 ± 900 HASS 600-S V OUT Output voltage (Analog) @ I P V REF ±(0.625· I P / I PN )V I P = 0 V REF ± 0.025 V G Output voltage (without offset) @ I PN ± 0.625 ± 1 % V V REF Reference voltage 1) - Output voltage 2.5 ± 0.025 V V REF Output impedance typ. 200 V REF Load impedance 200 kR L Load resistance 2 k R OUT Output internal resistance < 10 C L Capacitive loading < 1 μF V C Supply voltage (± 5 %) 5 V I C Current consumption @ V C = 5 V 22 mA Accuracy - Dynamic performance data X Accuracy 2) @ I PN , T A = 25°C ± 1 % of I PN e L Linearity error 0.. I PN ± 0.5 % of I PN .. I P ± 1 % of I PN TCV OUT Temperature coefficient of V OUT @ I P = 0 ± 0.3 mV/K TCV REF Temperature coefficient of V REF ± 0.01 %/K TCV OUT /V REF Temperature coefficient of V OUT / V REF @ I P = 0 ± 0.2 mV/K TCG Temperature coefficient of G ± 0.05% of reading/K V OM Magnetic offset voltage @ I P = 0, after an overload of 3 x I PN DC < ± 0.4 % of I PN t ra Reaction time @ 10 % of I PN < 3 μs t r Response time to 90 % of I PN step < 5 μs di/dt di/dt accurately followed > 100 A/μs V no Output voltage noise(DC ..10 kHz) < 20 mVpp (DC .. 1 MHz) < 40 mVpp BW Frequency bandwidth (- 3 dB) 3) DC .. 50 kHz Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Isolation test voltage 3300V Low power consumption Single power supply +5V Fixed offset & gain Isolated plastic case recognized according to UL 94-V0 Advantages Easy installation Small size and space saving Only one design for wide current ratings range High immunity to external interference. Internal and external reference Applications AC variable speed drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Application domain Industrial I PN = 50 .. 600 A Notes : 1) It is possible to overdrive V REF with an external reference voltage between 2 - 2.8 V providing its ability to sink or source approximately 2.5 mA. 2) Excluding offset and hysteresis. 3) Small signal only to avoid excessive heatings of the magnetic core. 081007/7 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 1/3

Upload: phungquynh

Post on 12-Mar-2018

219 views

Category:

Documents


2 download

TRANSCRIPT

Current Transducer HASS 50..600-SFor the electronic measurement of currents : DC, AC, pulsed, mixed,with a galvanic isolation between the primary circuit (high power)and the secondary circuit (electronic circuit).

All Data are given with a RL = 10 kΩ

Electrical dataPrimary nominal Primary current Type

current rms measuring rangeIPN (A) IPM (A)

50 ± 150 HASS 50-S100 ± 300 HASS 100-S200 ± 600 HASS 200-S300 ± 900 HASS 300-S400 ± 900 HASS 400-S500 ± 900 HASS 500-S600 ± 900 HASS 600-S

VOUT Output voltage (Analog) @ IP VREF ± (0.625·IP/IPN) VIP = 0 VREF ± 0.025 V

G Output voltage (without offset) @ IPN ± 0.625 ± 1 % VVREF Reference voltage 1) - Output voltage 2.5 ± 0.025 V

VREF Output impedance typ. 200 ΩVREF Load impedance ≥ 200 kΩ

R L Load resistance ≥ 2 kΩROUT Output internal resistance < 10 ΩC L Capacitive loading < 1 µFVC Supply voltage (± 5 %) 5 VIC Current consumption @ VC = 5 V 22 mA

Accuracy - Dynamic performance data

X Accuracy 2) @ IPN , TA = 25°C ≤ ± 1 % of IPN

ε L Linearity error 0.. IPN ≤ ± 0.5 % of IPN

.. IP ≤ ± 1 % of IPN

TCVOUT Temperature coefficient of VOUT @ IP = 0 ≤ ± 0.3 mV/KTCVREF Temperature coefficient of VREF ≤ ± 0.01 %/KTCVOUT / VREF Temperature coefficient of VOUT / VREF @ IP = 0 ≤ ± 0.2 mV/KTCG Temperature coefficient of G ≤ ± 0.05% of reading/K

VOM Magnetic offset voltage @ IP = 0,after an overload of 3 x IPN DC < ± 0.4 % of IPN

tra Reaction time @ 10 % of IPN < 3 µst r Response time to 90 % of IPN step < 5 µsdi/dt di/dt accurately followed > 100 A/µsVno Output voltage noise(DC ..10 kHz) < 20 mVpp

(DC .. 1 MHz) < 40 mVppBW Frequency bandwidth (- 3 dB) 3) DC .. 50 kHz

Features

• Hall effect measuring principle• Galvanic isolation between primary

and secondary circuit• Isolation test voltage 3300V• Low power consumption• Single power supply +5V• Fixed offset & gain• Isolated plastic case recognized

according to UL 94-V0

Advantages

• Easy installation• Small size and space saving• Only one design for wide current

ratings range• High immunity to external

interference.• Internal and external reference

Applications

• AC variable speed drives• Static converters for DC motor drives• Battery supplied applications• Uninterruptible Power Supplies (UPS)• Switched Mode Power Supplies

(SMPS)• Power supplies for welding applications.

Application domain

• Industrial

IPN = 50 .. 600 A

Notes :1) It is possible to overdrive VREF with an external reference voltage between

2 - 2.8 V providing its ability to sink or source approximately 2.5 mA.2) Excluding offset and hysteresis.3) Small signal only to avoid excessive heatings of the magnetic core.

081007/7 www.lem.comLEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.

Page 1/3

Current Transducer HASS 50..600-S

General dataTA Ambient operating temperature - 40 .. + 85 °CTS Ambient storage temperature - 40 .. + 85 °Cm Mass 55 g

Standard EN 50178: 1997

Isolation characteristics

Vb Rated isolation voltage rms 150 Vwith IEC 61010-1 standards and following conditions

- Reinforced isolation- Over voltage category III- Pollution degree 2- Heterogeneous field

Vb Rated isolation voltage rms 300 Vwith EN 50178 standards and following conditions

- Reinforced isolation- Over voltage category III- Pollution degree 2- Heterogeneous field

Vd Rms voltage for AC isolation test, 50 Hz, 1 min 3.3 kVVe Partial discharge extinction voltage rms @ 10 pC > 1 kVVw Impulse withstand voltage 1.2/50 µs 6 kVdCp Creepage distance > 5.5 m mdCl Clearance distance > 5.5 m mCTI Comparative tracking index (Group I ) > 600 V

If isolated cable is used for the primary circuit, thevoltage category could be improved with the following table :

Cable isolation (primary) CategoryHAR 03 300V CAT IIIHAR 05 400V CAT IIIHAR 07 500V CAT III

081007/7 www.lem.comLEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.

Page 2/3

Safety

This transducer must be used in electric/electronic equipment with respect toapplicable standards and safety requirements in accordance with the manufacturer'soperating instructions.

Caution! Risk of electrical shock

When operating the transducer, certain parts of the module can carry hazardousvoltage (eg. primary busbar, power supply).Ignoring this warning can lead to injury and/or cause serious damage.This transducer is a built-in device, whose conducting parts must be inaccessibleafter installation.A protective housing or additional shield could be used.Main supply must be able to be disconnected.

Dimensions HASS 50..600-S (in mm. 1 mm = 0.0394 inch)

Ip 0V

Vref.(IN/OUT)

Vout

+Vc

Operation Principle

Required Connection Circuit

+5V

0V

Output Output

0V

+5V

1

2

3

4

Vref(IN/OUT) Vref(IN/OUT)

HASS

RL=10Kohm

Mechanical characteristics

• General tolerance ± 0.5 mm• Aperture for primary conductor 20.4 x 10.4 ± 0.5 mm• Transducer fastening M4• Recommended fastening torque < 1.5 Nm• Connection of secondary Molex 5045-04A

Remarks

• Arrow indicates positive current flow direction.• Temperature of the primary conductor should not exceed

100°C

Ip

10.4

16

22.8

d4.5

R5.2

2.5

20

30 +

/-0.

5

40 +/-0.5

55

20

4.8 9.

8

3

d2.5

10.4

20.4

Molex

R0.5

14

1...Vref(IN/OUT)2...OUTPUT3...0V4...+5V

Terminal Pin

5045-04A

081007/7 www.lem.comLEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.