current transducers - flex-core.comrms current transducer model mctr 1 12 output zero span model 3 4...

1
CURRENT TRANSDUCERS PHONE (614) 889-6152 TECH. ASSISTANCE (614) 876-8308 FAX # (614) 876-8538 4970 Scioto Darby Rd. Hilliard, Ohio 43026 Div. Morlan & Associates, Inc. WWW.FLEX-CORE.COM sales@flex-core.com 95 CURRENT TRANSDUCERS RMS CURRENT TRANSDUCER MODEL MCTR 1 1 2 OUTPUT ZERO SPAN MODEL 4 3 OUTPUT INPUT 0-0.333VAC LOAD LINE LOAD LINE OUTPUT OUTPUT 15-35Vdc 15-35Vdc 15-35Vdc 2 3 4 1 2 3 4 1 2 3 4 DIRECT CURRENT INPUT VOLTAGE INPUT USING EXTERNAL CTS ALL MODELS 2-WIRE LOOP POWERED, TRUE RMS Accurate RMS measurement of AC input 4-20mAdc 2-wire loop powered UL94V-0 Polyamide DIN-mount case Slim profile allows maximum use of available space Recessed terminals provide increased safety *Note: 0.333V model requires isolation through CTs. All Dimensions In Inches. Transducer output is derived from the RMS value of the input. DIN-rail lengths available: Consult Factory Designed for use with current transformers Use with any CT with 0.1A, 1A, 5A, or 0.333V output True RMS transducer for accurately sensing current in single and 3-phase installations. Ideal for non-sinusoidal applications DIMENSIONS SPECIFICATIONS CONNECTION DIAGRAMS INPUT AC CURRENT STANDARD OUTPUT MODEL MCTR- 4-20mAdc 0-0.1A 0.100E2 0-1A 001E2 0-5A 005E2 0-0.333V *0.333E2 INPUT Current or Voltage..................................................... See Table Frequency Range .... Standard ................................... 50-60Hz Burden ........ 0.1A &1A models ..................................... 0.05VA 5A models ..................................... 0.18VA 0.333V models ................................... 0.004VA Current Overload Continuous ........................................... 1.5 X F.S. Rating Transient (10s/hr)...................................... 5 X F.S. Rating OUTPUT Scaling ................................... 0-F.S. Input = 4-20mAdc Output Response ................. (to 90%) ...................................... 300ms Loading ..(@24Vdc. Instr. Pwr) .....................................0-500Ω Set Point Adjustment .........................................+5% minimum DIELECTRIC TEST Input/Output ................ Current input models ..............2220Vac NOTE: 0.333V model requires isolation through the current transformer. INSTRUMENT POWER Loop-powered............ Nominal ...................................... 24Vdc Range ................................. 15-35Vdc ACCURACY (Includes effects of linearity and setpoint) 50/60Hz ............. 10-100% F.S. ............................. +0.25% F.S. Output Ripple....................................................... <1.0% pk-pk TEMPERATURE Operating Range ............................................. -20°C to +60°C Effect ...................................................................... +1.0% F.S. PHYSICAL Termination Wire Size ........................................ 22 to 12 AWG Weight ........................................................................... 0.4 Lb. Unit can be mounted on ............... RAIL EN50035 (DIN 1) OR RAIL EN5022 (DIN 2) 3.10 3.37 3.56 3.66 1.00 FEATURES APPLICATIONS Example: 0-0.1A Input with 4-20mA Loop Powered Output. MCTR-0.100E2 ORDERING INFORMATION

Upload: others

Post on 01-Sep-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CURRENT TRANSDUCERS - flex-core.comRMS CURRENT TRANSDUCER MODEL MCTR 1 12 OUTPUT ZERO SPAN MODEL 3 4 OUTPUT INPUT LINE LOAD 0-0.333VAC LINE LOAD OUTPUT OUTPUT 15-35Vdc 15-35Vdc 15-35Vdc

CURRENT TRANSDUCERS

PHONE (614) 889-6152TECH. ASSISTANCE (614) 876-8308

FAX # (614) 876-85384970 Scioto Darby Rd. Hilliard, Ohio 43026Div. Morlan & Associates, Inc.

[email protected]

95

CU

RR

EN

T T

RA

NS

DU

CE

RS

RMS CURRENT TRANSDUCER MODEL MCTR

1

1 2

OUTPUT

ZERO

SPAN

MODEL

43

OUTPUT

INPUT0-0.333VACLOADLINE

LOADLINE

OUTPUT

OUTPUT 15-35Vdc

15-35Vdc 15-35Vdc

2 3 4 1 2 3 4

1 2 3 4

DIRECT CURRENT INPUT VOLTAGE INPUT

USING EXTERNAL CTS ALL MODELS

2-WIRE LOOP POWERED, TRUE RMS• Accurate RMS measurement of AC input• 4-20mAdc 2-wire loop powered• UL94V-0 Polyamide DIN-mount case• Slim profile allows maximum use of available space• Recessed terminals provide increased safety

*Note: 0.333V model requires isolation through CTs.

All Dimensions In Inches.

Transducer output is derived from the RMS value of the input.DIN-rail lengths available: Consult Factory

• Designed for use with current transformers• Use with any CT with 0.1A, 1A, 5A, or 0.333V output• True RMS transducer for accurately sensing current in

single and 3-phase installations.• Ideal for non-sinusoidal applications

DIMENSIONS

SPECIFICATIONS

CONNECTION DIAGRAMS

INPUT AC CURRENT

STANDARD OUTPUT MODEL MCTR-

4-20mAdc

0-0.1A 0.100E2

0-1A 001E2

0-5A 005E2

0-0.333V *0.333E2

INPUTCurrent or Voltage .....................................................See TableFrequency Range .... Standard ...................................50-60HzBurden ........ 0.1A &1A models .....................................0.05VA 5A models .....................................0.18VA 0.333V models ...................................0.004VACurrent Overload Continuous ...........................................1.5 X F.S. Rating Transient (10s/hr) ......................................5 X F.S. RatingOUTPUTScaling ................................... 0-F.S. Input = 4-20mAdc OutputResponse ................. (to 90%) ......................................300msLoading .. (@24Vdc. Instr. Pwr) .....................................0-500ΩSet Point Adjustment .........................................+5% minimumDIELECTRIC TESTInput/Output ................Current input models ..............2220VacNOTE: 0.333V model requires isolation through the current transformer.INSTRUMENT POWERLoop-powered ............ Nominal ...................................... 24Vdc Range ................................. 15-35VdcACCURACY (Includes effects of linearity and setpoint)50/60Hz .............10-100% F.S. ............................. +0.25% F.S.Output Ripple ....................................................... <1.0% pk-pkTEMPERATUREOperating Range ............................................. -20°C to +60°CEffect ...................................................................... +1.0% F.S.PHYSICALTermination Wire Size ........................................ 22 to 12 AWGWeight ...........................................................................0.4 Lb.Unit can be mounted on ............... RAIL EN50035 (DIN 1) OR RAIL EN5022 (DIN 2)

3.10

3.373.56

3.66

1.00

FEATURES

APPLICATIONSExample: 0-0.1A Input with

4-20mA Loop Powered Output.MCTR-0.100E2

ORDERING INFORMATION