curved cc5 rf - cossiga.com · cut out s e e supplied 5mm pvc wedge strip to sides for drop-in unit...
TRANSCRIPT
Download C.A.D models or contact us on COSSIGA.COMPage 1
CURVED CC5
CC5 RF6CC5 RF9CC5 RF12CC5 RF15
CC5 HT6CC5 HT9CC5 HT12
RF
HT
Deck forced refrigerationSliding doors front and rearDouble glazedTwo adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsIntegral condensorSelf evaporatingSolid glass front - optional
Sliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optional
Download C.A.D models or contact us on COSSIGA.COMPage 2
CURVED CC5
ABSliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optionalAmbient converted from heatedAir removal fan installed in ceiling
CC5 AB6CC5 AB9CC5 AB12
BMSliding doors front and rearOverhead halogen lightsWet / dry element in baseSingle glazed glassSolid glass front - optional
CC5 BM6CC5 BM9CC5 BM12
Download C.A.D models or contact us on COSSIGA.COMPage 3
CABINET DIMENSIONS & SPECIFICATIONS
CURVED CC5 Dimensions
MODEL CABINET SHELVING SHELVING SIZES FREQUENCY REFRIGERANT TOTALFOOD
OPERATING CURRENT
CONNECTION VOLTAGE PACKED FOR SHIPPING
LENGTH [MM]
DEPTH[MM]
HEIGHT[MM]
CUTOUTS
TOP 2ND 3RD BASE 100MMUNITS
LENGTH [MM]
DEPTH[MM]
HEIGHT[MM]
WEIGHT[KG]
CUBE
CC5RF6 600 650 925 615x620 2 + BASE 490 X 325 490 X 405 545 X 415 134A 55 3.2 AMP 10AMP 3 PIN PLUG 240V 700 730 1400 126 0.71
CC5RF9 900 650 925 915x620 2 + BASE 790 X 325 790 X 405 845 X 415 134A 84 3.7 AMP 10AMP 3 PIN PLUG 240V 1000 730 1445 154 1.05
CC5RF12 1200 650 925 1215x620 2 + BASE 1090 X 325
1090 X 405 1145 X 415 134A 121 4.6 AMP 10AMP 3 PIN PLUG 240V 1300 730 1445 204 1.37
CC5RF15 1500 650 925 1515x620 2 + BASE 1390 X 325
1390 X 405 1445 X 415 134A 154 5.0 AMP 10AMP 3 PIN PLUG 240V 1600 730 1445 221 1.68
CC5HT6 600 650 925 615x620 3 + BASE 490 X 325 490 X 365 490 X 395 545 x 415 N/A 75 4.6 AMP 10AMP 3 PIN PLUG 240V 700 730 1100 83 0.56
CC5HT9 900 650 925 915x620 3 + BASE 790 x 325 790 x 365 790 x 395 845 x 415 N/A 120 6.2 AMP 10AMP 3 PIN PLUG 240V 1000 730 1100 106 0.80
CC5HT12 1200 650 925 1215x620 3 + BASE 1090 x 325 1090 x 365 1090 x 395 1145 x 415 N/A 154 7.7 AMP 10AMP 3 PIN PLUG 240V 1300 730 1100 130 1.04
CC5AB6 600 650 925 615x620 3 + BASE 490 x 325 490 x 365 490 x 395 545 x 415 N/A 55 0.2 AMP 10AMP 3 PIN PLUG 240V 700 730 1100 83 0.56
CC5AB9 900 650 925 915x620 3 + BASE 790 x 325 790 x 365 790 x 395 845 x 415 N/A 84 0.3 AMP 10AMP 3 PIN PLUG 240V 1000 730 1100 106 0.80
CC5AB12 1200 650 925 1215x620 3 + BASE 1090 x 325 1090 x 365 1090 x 395 1145 x 415 N/A 121 0.4 AMP 10AMP 3 PIN PLUG 240V 1300 730 1100 130 1.04
CC5BM9 900 650 925 915x620 4 x 1/2 - 65mm Gastro Pans LEAD ONLY N/A 154 9.9 AMP 15 AMP SUPPLY 240V 1000 730 1100 87 0.80
CC5BM12 1200 650 925 1215x620 6 x 1/2 - 65mm Gastro Pans LEAD ONLY N/A 11 AMP 15 AMP SUPPLY 240V 1300 730 1100 117 1.04
CC5BM15 1500 650 925 1515x620 8 x 1/2 - 65mm Gastro Pans LEAD ONLY N/A 15 AMP 20 AMP SUPPLY 240V 1600 730 1100 146 1.28
Download C.A.D models or contact us on COSSIGA.COMPage 4
REMOTE INSTALLATION AND SERVICES
Units are self evaporating to a receptacle in the condensor unitIn areas of high humidity units should be plumbed directly to a waste.
Plumbed Receptacle
- Maximum 150mm above finished floor level
- Drainage to building waste
- Building waste by client
- Receptacle placed under unit
- Dispose of water daily
3/8” pipe max run 1500 mm
condensate drainto four litre container
Vertical pipe runs are not recommended
Pipe runs over 150mm : - Expansion valve will need to be fitted - Correctly sized condensing unit fitted - Correct pipe size determined
Download C.A.D models or contact us on COSSIGA.COMPage 5
JOINERY AIR FLOW CONSIDERATIONS
Closed rear. Front vented
Intake and extract vents.Min 400mm x 400mm openarea.
Joinery divider panelproviding sealed air intakeplenum with cutout to meetcondenser face
200mm clearspace
200mm clearspace
350 mm
260
mm
varies
vari
es
Hole Cut to meet condenser face
Open at rear
Closed front
Joinery divider panelproviding sealed air intakeplenum with cutout to meetcondenser face
200mm clearspace
200mm clearspace
Front Vented Rear Vented
Download C.A.D models or contact us on COSSIGA.COMPage 6
EXTRACTION FAN
Extract hot air from box joinery
Fan and power cable supplied, screw fixed to joinery
Electrical power cord 2000mm 3 pin 10 amp 1 phase socket required
Fan 230v ~ 50Hz - 60Hz - 19 Watt in stainless steel case
EXTRACTION FAN
Download C.A.D models or contact us on COSSIGA.COMPage 7
DROP IN COUNTER TOP CUT OUT DETAILS
Cut out 585 mm
Cut out 525 mmmin 75 mm
min 75 mm
Condensor unit545w x 485d x 390h(C4RF6 485w x 485d x 335h)
RF6 Cut out 525 mmRF6 Cut out 525 mm
ALLO
W 4
00 m
m
Open at rear.
150 mm
Cut out see table
Supplied 5mm PVCwedge strip to sidesfor drop-in unit
Cut out 620 mmmin 20 mm
min 20 mm
Condensor unit545w x 485d x 390h(C4RF6 485w x 485d x 335h)
ALLO
W 4
00 m
m
Open at rear.
Remove feet for alldrop-in installations
Supplied 5mm PVCwedge strip to sidesfor drop-in unit.No glue or sealant required
Download C.A.D models or contact us on COSSIGA.COMPage 8
JOINERY TO REAR WALL WITH VENT
Horizontal vent in cabinet top for hot air extract
Electric biscuit fans can also be fitted to provide mechanical extract
Ambient air ducted in to compressor face through air plenum space
Joinery divider panel providing sealed air intake plenum with cut out to meet condensor face
Allow access for cleaning, servicing and waste evaporator water removal
Ambient air is drawn into front vented area Hot air must escape joinery cabinet A horizontal vent should be used behind the unit
Vent must be at least 100mm deep and as wide as unit
Download C.A.D models or contact us on COSSIGA.COMPage 9
AIRFLOW AND PLACEMENT GUIDE LINES
CORRECT AIR FLOW INCORRECT AIR FLOW
CLEAR FLOW
NO AIR FLOW
AIR FLOW BLOCKED
too much chilled airaround coil can createexcessive ice build up
Blocked air flow will retard operation on both HOT and COLD units
Ensure trays or plates are not blocking air flow at rear
Heat from other equipment and natural conditions can cause cooling failures and overheating of compressors
Locations to avoid are :
Close to shop front exterior In an outside location In direct sunlight In a high cross wind area Near any source producing excessive heat
Download C.A.D models or contact us on COSSIGA.COMPage 10
Ventilation Grill
CC5 ACCESSORIES
Top Mounted Controller Panel
Price Tabs
Base Tray - Heated Units
Tong Holder
Bag Holder
Humidity Dish
For against wall installationsSold individually
Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20
Stainless SteelSold individually
Stainless SteelDrop into counter tray raceSolid individually
Stainless SteelDrop into counter tray raceSold individually
Stainless SteelFor heated unitsSold in pairs
Stainless SteelPerforated lid is removable
450
mm
450 mm
100 mm
190 mm
80 mm
180
mm
220 mm
190 mm
105 mm
75 mm
Download C.A.D models or contact us on COSSIGA.COMPage 11
TICKET STRIP
Price TabsLengths
Ticket Strip
Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20
Stainless SteelFits over front of shelves
CABINETLENGTH MM
TICKET STRIP LENGTH
600 475
900 775
1200 1075
1500 1375
End Profile
Download C.A.D models or contact us on COSSIGA.COMPage 12
MIRROR FILM
Applied to the inside glass rear doors
Suitable for heated and chilledunits
Mirror film adhered to inside of rear door glass
Mirror film adhered to inside of rear door glass
FREE STANDING UNITS BENCHTOP UNITS
Blocks work areasbehind units
Add depth toyour displays
Download C.A.D models or contact us on COSSIGA.COMPage 13
THERMAL BARRIERS
BENCHTOP DROP IN
BENCHTOP DROP IN
BENCHTOP
BENCHTOP
CC5 -TBDI
STG -TBDI
CC5 -TBC
STG -TBC
Thermal spacer barriers
Provides thermal separation between hot and cold units with minimum spacing
Provides a continuous look
20mm Clear polycarbonate with polished edges
Download C.A.D models or contact us on COSSIGA.COMPage 14
Pie Trays
PIE TRAYS PIE TRAYS
MODEL CODE QUANTITY 1ST SHELFDEPTH
2ND SHELFDEPTH
3RD SHELFDEPTH
TOTAL SHELFWIDTH
CC5HT6 AA16015 4 Per Shelf 325MM 365MM 395MM 12 Trays 120MM
CC5HT9 AA16016 6 Per Shelf 325MM 365MM 395MM 18 Trays 130MM
CC5HT12 AA16017 9 Per Shelf 325MM 365MM 395MM 27 Trays 120MM
Gastro Norm System
GASTRO NORM
MODEL CODE QUANTITY DIMENSIONS PAN DEPTH
CC5HT6 F92-315 2 Per Unit 265MM X 325MM PANS AND FRAME 65MM
CC5HT9 F92-316 3 Per Unit 265MM X 325MM PANS AND FRAME 65MM
CC5HT12 F92-317 4 Per Unit 265MM X 325MM PANS AND FRAME 65MM
HEATED UNIT ACCESSORIES
Stainless Steel ConstructionPlaced on shelves for heated food items
Stainless Steel ConstructionAngled display view
Download C.A.D models or contact us on COSSIGA.COMPage 1
CURVED CD5 REFRIGERATED
CD5 RF9CD5 RF12CD5 RF15RF
OR CD5 OR9CD5 OR12
Deck forced refrigerationSliding Doors front and rearDouble glazedArgon filled rear doorsThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsIntegral condensorSelf evaporatingSolid glass front - optional
Open frontStainless steel hinged rear doorsDeck forced refrigerationDouble glazed endsTwo adjustable glass shelvesTicket strips on shelves and baseUndershelf and canopy LED lights
Download C.A.D models or contact us on COSSIGA.COMPage 2
CURVED CD5 HEATED/AMBIENT
CD5 HT9CD5 HT12CD5 HT15HT
AB CD5 AB9CD5 AB12CD5 AB15
Deck forced heatingSingle glazedSliding rear doorsFour adjustable shelvesTicket strips on shelves and baseUndershelf and canopy LED lightsSolid front glass - optional
Sliding doors front and rearSingle glazedFour adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid front glass - optionalAmbient converted from heatedAir removal fan installed in ceiling
Download C.A.D models or contact us on COSSIGA.COMPage 3
CABINET DIMENSIONS & SPECIFICATIONS
CURVED CD5 DIMENSIONS
MODEL CABINET SHELVING SHELVING SIZES REFRIGERANT TOTALFOOD
DISPLAY OPERATING CURRENT
CONNECTION VOLTAGE PACKED FOR SHIPPING
LENGTH [MM]
DEPTH[MM]
HEIGHT[MM]
TOP 2ND 3RD 4TH BASE 100MMUNITS M2
LENGTH [MM]
DEPTH[MM]
HEIGHT[MM]
WEIGHT[KG]
CUBE
CD5RF9 900 750 1380 3 + BASE 790 X 365 790 X 445 790 X 465 845X510 134A 144 1.42 4.5 AMP 10AMP 3 PIN PLUG 240V 1000 830 1550 213 1.2865
CD5RF12 1200 750 1380 3 + BASE 1090X365 1090X445 1090X465 1145X510 134A 188 1.97 5.0 AMP 10AMP 3 PIN PLUG 240V 1300 830 1550 235 1.672
CD5RF15 1500 750 1380 3 + BASE 1390X365 1390X445 1390X465 1445X510 134A 252 2.50 6.0 AMP 10AMP 3 PIN PLUG 240V 1600 830 1550 282 2.058
CD5HT9 900 750 1380 4 + BASE 790x365 790x365 790x445 790x465 845x510 N/A 160 1.73 6.2 AMP 10AMP 3 PIN PLUG 240V 1000 830 1550 144
CD5HT12 1200 750 1380 4 + BASE 1090x365 1090x365 1090x445 1090x465 1145x510 N/A 205 2.51 8.3 AMP 10AMP 3 PIN PLUG 240V 1300 830 1550 144
CD5HT15 1500 750 1380 4 + BASE 1390x365 1390x365 1390x445 1390x465 1445x510 N/A 252 10.4 AMP 15AMP 3 PIN PLUG 240V 1300 830 1550 220
CD5AB9 900 750 1380 4 + BASE 790x365 790x365 790x445 790x510 790x510 N/A 144 0.3 AMP 10AMP 3 PIN PLUG 240V 1000 830 1550 106 0.80
CD5AB12 1200 750 1380 4 + BASE 1090 x 325 1090 x 365 1090 x 395 1090x445 1145x510 N/A 205 0.4 AMP 10AMP 3 PIN PLUG 240V 1300 830 1100 130 1.04
CD5AB15 1500 750 1380 4 + BASE 1090 x 325 1090 x 365 1090 x 445 1390x445 1445x510 N/A 252 0.5 AMP 10AMP 3 PIN PLUG 240V 1300 830 1100 130 1.04
CD5OR9 900 750 1380 2 + BASE 1090 x 365 1090 x 445 134A 104 4.8 AMP 10AMP 3 PIN PLUG 240V 1000 830 1100 213 1.2865
CD5OR12 1200 750 1380 2 + BASE 1090 x 365 1090 x 445 134A 125 5.8 AMP 10AMP 3 PIN PLUG 240V 1300 830 1100 235 1.672
Download C.A.D models or contact us on COSSIGA.COMPage 4
CD5 RF9 CD5 RF15CD5 RF12
1380
1380
1380
CURVED CD5 RF
Download C.A.D models or contact us on COSSIGA.COMPage 6
CD5 HT9 / AB9 CD5 HT15 /AB15CD5 HT12 / AB12
1380
1380
1200
1380
CURVED CD5 HT CD5 AB
Download C.A.D models or contact us on COSSIGA.COMPage 7
DRAINAGE - OPTIONAL
To Waste
To Waste Water Drain
Condensate drain pipe
The condensate waste pipe may be plumbed directly to the building drainage system
Download C.A.D models or contact us on COSSIGA.COMPage 8
REAR VENTILATION
Ambient air intake throughright rear
Exhaust air extract throughleft rear internally ducted to envionment
Rear intake and extract ventilation system Side mounted compressor
Front can be fully covered with custom panel joinery to suit environment
Rear Ventilation
A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed hard up against a wall
Separation To Wall
Standard Configuration as shipped
Rear grill removed and replaced with solid panel
Standard rear grill Standard front baffle
Front baffle panel removed and discarded
Front grill detached and re-attached after configuration change
Air flow intake from left rear side and exhaust through right rear side
Optional Configuration - Front to Front
Air flow intake from left front side and exhaust through right front side
Download C.A.D models or contact us on COSSIGA.COMPage 9
CD5 OPTIONAL FRONT VENTING
Back to back with front venting
Against a wall with front venting
Download C.A.D models or contact us on COSSIGA.COMPage 10
PLACEMENT GUIDES
Blocked air flow will retard operation on both HOT and COLD units
Ensure trays or plates are not blocking air flow at rear
CORRECT AIR FLOW INCORRECT AIR FLOW
CLEAR FLOW AIR FLOW BLOCKED
too much chilled airaround coil can createexcessive ice build up
NO AIR FLOW
Mechanical air flows, such as diffusers and fans can disturb the air curtain on open fronted units causing failure
Heat from other equipment and natural conditions, such as direct sunlight straight on units, can cause cooling to fail and over compressor
Natural disruptive air flow suchas cross winds can disturb the air curtain on open frontedunits causing cooling to fail
Locations to avoid :
- Close to shop front exterior - In a high wind- In an outsdie location - Near any source producing excessive heat- In direct sunlight - Service units more frequently in dusty or polluted areas
Download C.A.D models or contact us on COSSIGA.COMPage 11
PLACED IN BENCH DETAIL
Dropped Into Benchtop
Placed Into Benchtop from rear
Parts removed
MODEL CUT OUT SIZE
CD5 6 615 X 720
CD5 9 915 X 720
CD5 12 1215 X 720
CD5 15 1515 X 720
SupportSupport
Support
Unit is dropped in to hole cut in bench top and supported by font and rear flange of unit.
Unit is slid into custom built frame from rear and supported by the sides of the unit base frame. L shaped supports shown in red in this example.Castors, front and side panels removed.
Rear panels / grill remain for personnel safety.
Download C.A.D models or contact us on COSSIGA.COMPage 12
Easy install option to eliminate a nib wallSimply roll in and clip on
Clip on panels offered in routed 18mm MDFMelteca finish in three colour options600/900/1200/100 lengths options with end panels
Affinity Maple
Bliss Shitake
Burnished Wood
COPS CLIP ON PANEL SYSTEM
Download C.A.D models or contact us on COSSIGA.COMPage 13
Bottom edge sits flush with bottom of panel
Double sided velcro
Clips screw fixed topanel
end panels
Integrated Clip System - Bracket fixing to joinery panels
COPS CLIP ON PANEL SYSTEM
Download C.A.D models or contact us on COSSIGA.COMPage 14
CD5 SELF SERVICE SYSTEM
SELF SERVICE SYSTEM
Each unit is self containedRoll-in - Roll-outInstall in minutesNo on site joinery work requiredEase of cleaning and servicingMobile and flexibleEasy to upgrade front panel designCustom branding stripRear service or against wallAll parts as optional component kitsIdeal solution for temporary events
Optional bottom shelf kit for chilled unitsEnsure chilled units are kept well ventilated
Vent required through front panel
Optional bottom meltica shelf kit - BY OTHERS
Optional rear loading shelf kit 200mm deep
Optional bottom meltica shelf kit - BY OTHERS
Download C.A.D models or contact us on COSSIGA.COMPage 15
CD5 ACCESSORIES
Top Mounted Controller Panel
Price Tabs
For against wall installationsSold individually
Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20
Front and Rear Work ShelvesStainless SteelSold individually
Front
Rear
600 - 900 mm - 1200 mm - 1500 mm
600 - 900 mm - 1200 mm - 1500 mm
300 mm
250 mm
Castor Extension Kit
370
mm
280
mm
90 m
m
Increases cabinet height to 1660mm
Set of four, uses existing castors, includes fixing bolts and washers
Base Tray - Heated Units
Tong Holder
Bag Holder
Humidity Dish
100 mm
190 mm
80 mm
180
mm
220 mm
190 mm
105 mm
75 mm
Stainless SteelDrop into counter tray raceSold individually
Stainless SteelFor heated unitsSold in pairs
Stainless SteelPerforated lid is removable
Download C.A.D models or contact us on COSSIGA.COMPage 16
TICKET STRIP
Price TabsLengths
Ticket Strip
Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20
Stainless SteelFits over front of shelves
CABINETLENGTH MM
TICKET STRIP LENGTH
600 475
900 775
1200 1075
1500 1375
End Profile
Download C.A.D models or contact us on COSSIGA.COMPage 17
MERCHANDISE TRAY
Merchandise TrayClip on stainless steel tray for allfree standing units
Attached to front of unitBuilt in ticket stripAngled base for maximum display
Download C.A.D models or contact us on COSSIGA.COMPage 18
Charcuterie RackStainless steel heavy duty shelf brackets 3 x 20 dia Stanless steel tubes
190mm190mm
Replaces existing shelves to allow hanging of cured meats, cheeses etc.Available in 900 and 1200 lengths onlyMaximum of 50kgsHooks not included
Weight to be spread evenly over front, middle and rear
rods
CHARCUTERIE RACK
Download C.A.D models or contact us on COSSIGA.COMPage 19
MIRROR FILM
Applied to the inside glass rear doors
Suitable for heated and chilledunits
Mirror film adhered to inside of rear door glass
Mirror film adhered to inside of rear door glass
FREE STANDING UNITS BENCHTOP UNITS
Blocks work areasbehind units
Add depth toyour displays
Download C.A.D models or contact us on COSSIGA.COMPage 20
CD5 SHELVINGGlass Shelf Options
MODEL GLASS 1ST SHELF DIMENSIONS
2ND SHELFDIMENSIONSBOTTON SHELF MM
3RD SHELFDIMENSIONS
4TH SHELF DIMENSIONS
DEPTH[MM]
LENGTH[MM]
PANESPER SHELF
DEPTH(MM)
LENGTH (MM)
PANES PER SHELF
DEPTH (MM)
LENGTH (MM)
NO. OF PANES
DEPTH (MM)
LENGTH (MM)
NO. OF PANES
CD5RF9 6MM TOUGHENED 350 490 2 390 490 2 440 490 2
CD4RF12 6MM TOUGHENED 350 540 2 390 540 2 440 540 2
CD5RF15 6MM TOUGHENED 350 690 2 390 690 2 440 390 2
CD5HT* 6MM TOUGHENED 320 490 2 360 490 2 400 490 2 450 490 2
CC5HT12 6MM TOUGHENED 330 540 2 360 540 2 400 540 2 450 540 2
CD5HT15 6MM T(OUGHENED 320 690 2 360 690 2 400 690 2 450 690 2
Pie Trays
PIE TRAYS
MODEL NO. OF SHELF TRAYS
WIDTH MM
1ST SHELFDEPTH MM
2ND SHELFDEPTH MM
3RD SHELFDEPTHMM
4TH SHELFDEPTHMM
TOTALTRAYS
CD5HT9 6 PER SHELF 130 325 365 445 465 24
CD4RF12 9 PER SHELF 130 325 365 445 465 32
Standard wire racks are removed and replaced with 6mm toughened glass panes
Stainless Steel glass shelf support bracket
Stainless Steel Construction
1 Rack 1x 1/1 pan One rack with full size pan
1 Rack 1 RackOne rack with drop in divider
1 Rack 2 x 1/2 pan One rack 2 x half pans
1 Rack 5 x 1/9 pans 3 x 16 pansOne rack varrious size pans with divider
GASTRONORM PAN SYSTEM
MODEL PAN DEPTH RACKS NO.
CD5 6 65MM 1X 1/1
CD5 9 65MM 2 X 1/1
CD5 12 65MM 3 X 1/1
CD5 15 65MM 4 X 1/1
Download C.A.D models or contact us on COSSIGA.COMPage 21
GASTRO PAN RACK
Download C.A.D models or contact us on COSSIGA.COMPage 22
- COUNTER TOP MODEL - CURVED OR SQUARE
FREE STANDING - CURVED OR SQUARE
WRAP TRIMMINIG
FREE STANDING BEHIND NIB WALL - CURVED OR SQUARE
DROP IN COUNTER TOP MODEL - CURVED OR SQUAREall exterior visible areas covered
all exterior visible areas covered all exterior top visible areas covered
all exterior top visible areas covered
2mm gap left around rear frame
Rear of units cut around serial number plate, exhaust fan and controller
COLOUR WRAP OPTIONS