curved cc5 rf - cossiga.com · cut out s e e supplied 5mm pvc wedge strip to sides for drop-in unit...

36
Download C.A.D models or contact us on COSSIGA.COM Page 1 CURVED CC5 CC5 RF6 CC5 RF9 CC5 RF12 CC5 RF15 CC5 HT6 CC5 HT9 CC5 HT12 RF HT Deck forced refrigeration Sliding doors front and rear Double glazed Two adjustable shelves Ticket strips on shelves and deck Undershelf and canopy LED lights Integral condensor Self evaporating Solid glass front - optional Sliding doors front and rear Single glazed Three adjustable shelves Ticket strips on shelves and deck Undershelf and canopy LED lights Solid glass front - optional

Upload: lamngoc

Post on 26-Nov-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Download C.A.D models or contact us on COSSIGA.COMPage 1

CURVED CC5

CC5 RF6CC5 RF9CC5 RF12CC5 RF15

CC5 HT6CC5 HT9CC5 HT12

RF

HT

Deck forced refrigerationSliding doors front and rearDouble glazedTwo adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsIntegral condensorSelf evaporatingSolid glass front - optional

Sliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optional

Download C.A.D models or contact us on COSSIGA.COMPage 2

CURVED CC5

ABSliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optionalAmbient converted from heatedAir removal fan installed in ceiling

CC5 AB6CC5 AB9CC5 AB12

BMSliding doors front and rearOverhead halogen lightsWet / dry element in baseSingle glazed glassSolid glass front - optional

CC5 BM6CC5 BM9CC5 BM12

Download C.A.D models or contact us on COSSIGA.COMPage 3

CABINET DIMENSIONS & SPECIFICATIONS

CURVED CC5 Dimensions

MODEL CABINET SHELVING SHELVING SIZES FREQUENCY REFRIGERANT TOTALFOOD

OPERATING CURRENT

CONNECTION VOLTAGE PACKED FOR SHIPPING

LENGTH [MM]

DEPTH[MM]

HEIGHT[MM]

CUTOUTS

TOP 2ND 3RD BASE 100MMUNITS

LENGTH [MM]

DEPTH[MM]

HEIGHT[MM]

WEIGHT[KG]

CUBE

CC5RF6 600 650 925 615x620 2 + BASE 490 X 325 490 X 405 545 X 415 134A 55 3.2 AMP 10AMP 3 PIN PLUG 240V 700 730 1400 126 0.71

CC5RF9 900 650 925 915x620 2 + BASE 790 X 325 790 X 405 845 X 415 134A 84 3.7 AMP 10AMP 3 PIN PLUG 240V 1000 730 1445 154 1.05

CC5RF12 1200 650 925 1215x620 2 + BASE 1090 X 325

1090 X 405 1145 X 415 134A 121 4.6 AMP 10AMP 3 PIN PLUG 240V 1300 730 1445 204 1.37

CC5RF15 1500 650 925 1515x620 2 + BASE 1390 X 325

1390 X 405 1445 X 415 134A 154 5.0 AMP 10AMP 3 PIN PLUG 240V 1600 730 1445 221 1.68

CC5HT6 600 650 925 615x620 3 + BASE 490 X 325 490 X 365 490 X 395 545 x 415 N/A 75 4.6 AMP 10AMP 3 PIN PLUG 240V 700 730 1100 83 0.56

CC5HT9 900 650 925 915x620 3 + BASE 790 x 325 790 x 365 790 x 395 845 x 415 N/A 120 6.2 AMP 10AMP 3 PIN PLUG 240V 1000 730 1100 106 0.80

CC5HT12 1200 650 925 1215x620 3 + BASE 1090 x 325 1090 x 365 1090 x 395 1145 x 415 N/A 154 7.7 AMP 10AMP 3 PIN PLUG 240V 1300 730 1100 130 1.04

CC5AB6 600 650 925 615x620 3 + BASE 490 x 325 490 x 365 490 x 395 545 x 415 N/A 55 0.2 AMP 10AMP 3 PIN PLUG 240V 700 730 1100 83 0.56

CC5AB9 900 650 925 915x620 3 + BASE 790 x 325 790 x 365 790 x 395 845 x 415 N/A 84 0.3 AMP 10AMP 3 PIN PLUG 240V 1000 730 1100 106 0.80

CC5AB12 1200 650 925 1215x620 3 + BASE 1090 x 325 1090 x 365 1090 x 395 1145 x 415 N/A 121 0.4 AMP 10AMP 3 PIN PLUG 240V 1300 730 1100 130 1.04

CC5BM9 900 650 925 915x620 4 x 1/2 - 65mm Gastro Pans LEAD ONLY N/A 154 9.9 AMP 15 AMP SUPPLY 240V 1000 730 1100 87 0.80

CC5BM12 1200 650 925 1215x620 6 x 1/2 - 65mm Gastro Pans LEAD ONLY N/A 11 AMP 15 AMP SUPPLY 240V 1300 730 1100 117 1.04

CC5BM15 1500 650 925 1515x620 8 x 1/2 - 65mm Gastro Pans LEAD ONLY N/A 15 AMP 20 AMP SUPPLY 240V 1600 730 1100 146 1.28

Download C.A.D models or contact us on COSSIGA.COMPage 4

REMOTE INSTALLATION AND SERVICES

Units are self evaporating to a receptacle in the condensor unitIn areas of high humidity units should be plumbed directly to a waste.

Plumbed Receptacle

- Maximum 150mm above finished floor level

- Drainage to building waste

- Building waste by client

- Receptacle placed under unit

- Dispose of water daily

3/8” pipe max run 1500 mm

condensate drainto four litre container

Vertical pipe runs are not recommended

Pipe runs over 150mm : - Expansion valve will need to be fitted - Correctly sized condensing unit fitted - Correct pipe size determined

Download C.A.D models or contact us on COSSIGA.COMPage 5

JOINERY AIR FLOW CONSIDERATIONS

Closed rear. Front vented

Intake and extract vents.Min 400mm x 400mm openarea.

Joinery divider panelproviding sealed air intakeplenum with cutout to meetcondenser face

200mm clearspace

200mm clearspace

350 mm

260

mm

varies

vari

es

Hole Cut to meet condenser face

Open at rear

Closed front

Joinery divider panelproviding sealed air intakeplenum with cutout to meetcondenser face

200mm clearspace

200mm clearspace

Front Vented Rear Vented

Download C.A.D models or contact us on COSSIGA.COMPage 6

EXTRACTION FAN

Extract hot air from box joinery

Fan and power cable supplied, screw fixed to joinery

Electrical power cord 2000mm 3 pin 10 amp 1 phase socket required

Fan 230v ~ 50Hz - 60Hz - 19 Watt in stainless steel case

EXTRACTION FAN

Download C.A.D models or contact us on COSSIGA.COMPage 7

DROP IN COUNTER TOP CUT OUT DETAILS

Cut out 585 mm

Cut out 525 mmmin 75 mm

min 75 mm

Condensor unit545w x 485d x 390h(C4RF6 485w x 485d x 335h)

RF6 Cut out 525 mmRF6 Cut out 525 mm

ALLO

W 4

00 m

m

Open at rear.

150 mm

Cut out see table

Supplied 5mm PVCwedge strip to sidesfor drop-in unit

Cut out 620 mmmin 20 mm

min 20 mm

Condensor unit545w x 485d x 390h(C4RF6 485w x 485d x 335h)

ALLO

W 4

00 m

m

Open at rear.

Remove feet for alldrop-in installations

Supplied 5mm PVCwedge strip to sidesfor drop-in unit.No glue or sealant required

Download C.A.D models or contact us on COSSIGA.COMPage 8

JOINERY TO REAR WALL WITH VENT

Horizontal vent in cabinet top for hot air extract

Electric biscuit fans can also be fitted to provide mechanical extract

Ambient air ducted in to compressor face through air plenum space

Joinery divider panel providing sealed air intake plenum with cut out to meet condensor face

Allow access for cleaning, servicing and waste evaporator water removal

Ambient air is drawn into front vented area Hot air must escape joinery cabinet A horizontal vent should be used behind the unit

Vent must be at least 100mm deep and as wide as unit

Download C.A.D models or contact us on COSSIGA.COMPage 9

AIRFLOW AND PLACEMENT GUIDE LINES

CORRECT AIR FLOW INCORRECT AIR FLOW

CLEAR FLOW

NO AIR FLOW

AIR FLOW BLOCKED

too much chilled airaround coil can createexcessive ice build up

Blocked air flow will retard operation on both HOT and COLD units

Ensure trays or plates are not blocking air flow at rear

Heat from other equipment and natural conditions can cause cooling failures and overheating of compressors

Locations to avoid are :

Close to shop front exterior In an outside location In direct sunlight In a high cross wind area Near any source producing excessive heat

Download C.A.D models or contact us on COSSIGA.COMPage 10

Ventilation Grill

CC5 ACCESSORIES

Top Mounted Controller Panel

Price Tabs

Base Tray - Heated Units

Tong Holder

Bag Holder

Humidity Dish

For against wall installationsSold individually

Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20

Stainless SteelSold individually

Stainless SteelDrop into counter tray raceSolid individually

Stainless SteelDrop into counter tray raceSold individually

Stainless SteelFor heated unitsSold in pairs

Stainless SteelPerforated lid is removable

450

mm

450 mm

100 mm

190 mm

80 mm

180

mm

220 mm

190 mm

105 mm

75 mm

Download C.A.D models or contact us on COSSIGA.COMPage 11

TICKET STRIP

Price TabsLengths

Ticket Strip

Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20

Stainless SteelFits over front of shelves

CABINETLENGTH MM

TICKET STRIP LENGTH

600 475

900 775

1200 1075

1500 1375

End Profile

Download C.A.D models or contact us on COSSIGA.COMPage 12

MIRROR FILM

Applied to the inside glass rear doors

Suitable for heated and chilledunits

Mirror film adhered to inside of rear door glass

Mirror film adhered to inside of rear door glass

FREE STANDING UNITS BENCHTOP UNITS

Blocks work areasbehind units

Add depth toyour displays

Download C.A.D models or contact us on COSSIGA.COMPage 13

THERMAL BARRIERS

BENCHTOP DROP IN

BENCHTOP DROP IN

BENCHTOP

BENCHTOP

CC5 -TBDI

STG -TBDI

CC5 -TBC

STG -TBC

Thermal spacer barriers

Provides thermal separation between hot and cold units with minimum spacing

Provides a continuous look

20mm Clear polycarbonate with polished edges

Download C.A.D models or contact us on COSSIGA.COMPage 14

Pie Trays

PIE TRAYS PIE TRAYS

MODEL CODE QUANTITY 1ST SHELFDEPTH

2ND SHELFDEPTH

3RD SHELFDEPTH

TOTAL SHELFWIDTH

CC5HT6 AA16015 4 Per Shelf 325MM 365MM 395MM 12 Trays 120MM

CC5HT9 AA16016 6 Per Shelf 325MM 365MM 395MM 18 Trays 130MM

CC5HT12 AA16017 9 Per Shelf 325MM 365MM 395MM 27 Trays 120MM

Gastro Norm System

GASTRO NORM

MODEL CODE QUANTITY DIMENSIONS PAN DEPTH

CC5HT6 F92-315 2 Per Unit 265MM X 325MM PANS AND FRAME 65MM

CC5HT9 F92-316 3 Per Unit 265MM X 325MM PANS AND FRAME 65MM

CC5HT12 F92-317 4 Per Unit 265MM X 325MM PANS AND FRAME 65MM

HEATED UNIT ACCESSORIES

Stainless Steel ConstructionPlaced on shelves for heated food items

Stainless Steel ConstructionAngled display view

Download C.A.D models or contact us on COSSIGA.COMPage 1

CURVED CD5 REFRIGERATED

CD5 RF9CD5 RF12CD5 RF15RF

OR CD5 OR9CD5 OR12

Deck forced refrigerationSliding Doors front and rearDouble glazedArgon filled rear doorsThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsIntegral condensorSelf evaporatingSolid glass front - optional

Open frontStainless steel hinged rear doorsDeck forced refrigerationDouble glazed endsTwo adjustable glass shelvesTicket strips on shelves and baseUndershelf and canopy LED lights

Download C.A.D models or contact us on COSSIGA.COMPage 2

CURVED CD5 HEATED/AMBIENT

CD5 HT9CD5 HT12CD5 HT15HT

AB CD5 AB9CD5 AB12CD5 AB15

Deck forced heatingSingle glazedSliding rear doorsFour adjustable shelvesTicket strips on shelves and baseUndershelf and canopy LED lightsSolid front glass - optional

Sliding doors front and rearSingle glazedFour adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid front glass - optionalAmbient converted from heatedAir removal fan installed in ceiling

Download C.A.D models or contact us on COSSIGA.COMPage 3

CABINET DIMENSIONS & SPECIFICATIONS

CURVED CD5 DIMENSIONS

MODEL CABINET SHELVING SHELVING SIZES REFRIGERANT TOTALFOOD

DISPLAY OPERATING CURRENT

CONNECTION VOLTAGE PACKED FOR SHIPPING

LENGTH [MM]

DEPTH[MM]

HEIGHT[MM]

TOP 2ND 3RD 4TH BASE 100MMUNITS M2

LENGTH [MM]

DEPTH[MM]

HEIGHT[MM]

WEIGHT[KG]

CUBE

CD5RF9 900 750 1380 3 + BASE 790 X 365 790 X 445 790 X 465 845X510 134A 144 1.42 4.5 AMP 10AMP 3 PIN PLUG 240V 1000 830 1550 213 1.2865

CD5RF12 1200 750 1380 3 + BASE 1090X365 1090X445 1090X465 1145X510 134A 188 1.97 5.0 AMP 10AMP 3 PIN PLUG 240V 1300 830 1550 235 1.672

CD5RF15 1500 750 1380 3 + BASE 1390X365 1390X445 1390X465 1445X510 134A 252 2.50 6.0 AMP 10AMP 3 PIN PLUG 240V 1600 830 1550 282 2.058

CD5HT9 900 750 1380 4 + BASE 790x365 790x365 790x445 790x465 845x510 N/A 160 1.73 6.2 AMP 10AMP 3 PIN PLUG 240V 1000 830 1550 144

CD5HT12 1200 750 1380 4 + BASE 1090x365 1090x365 1090x445 1090x465 1145x510 N/A 205 2.51 8.3 AMP 10AMP 3 PIN PLUG 240V 1300 830 1550 144

CD5HT15 1500 750 1380 4 + BASE 1390x365 1390x365 1390x445 1390x465 1445x510 N/A 252 10.4 AMP 15AMP 3 PIN PLUG 240V 1300 830 1550 220

CD5AB9 900 750 1380 4 + BASE 790x365 790x365 790x445 790x510 790x510 N/A 144 0.3 AMP 10AMP 3 PIN PLUG 240V 1000 830 1550 106 0.80

CD5AB12 1200 750 1380 4 + BASE 1090 x 325 1090 x 365 1090 x 395 1090x445 1145x510 N/A 205 0.4 AMP 10AMP 3 PIN PLUG 240V 1300 830 1100 130 1.04

CD5AB15 1500 750 1380 4 + BASE 1090 x 325 1090 x 365 1090 x 445 1390x445 1445x510 N/A 252 0.5 AMP 10AMP 3 PIN PLUG 240V 1300 830 1100 130 1.04

CD5OR9 900 750 1380 2 + BASE 1090 x 365 1090 x 445 134A 104 4.8 AMP 10AMP 3 PIN PLUG 240V 1000 830 1100 213 1.2865

CD5OR12 1200 750 1380 2 + BASE 1090 x 365 1090 x 445 134A 125 5.8 AMP 10AMP 3 PIN PLUG 240V 1300 830 1100 235 1.672

Download C.A.D models or contact us on COSSIGA.COMPage 4

CD5 RF9 CD5 RF15CD5 RF12

1380

1380

1380

CURVED CD5 RF

Download C.A.D models or contact us on COSSIGA.COMPage 5

1380

CD5 OF12 CD5 OF9

CURVED CD5 OF

Download C.A.D models or contact us on COSSIGA.COMPage 6

CD5 HT9 / AB9 CD5 HT15 /AB15CD5 HT12 / AB12

1380

1380

1200

1380

CURVED CD5 HT CD5 AB

Download C.A.D models or contact us on COSSIGA.COMPage 7

DRAINAGE - OPTIONAL

To Waste

To Waste Water Drain

Condensate drain pipe

The condensate waste pipe may be plumbed directly to the building drainage system

Download C.A.D models or contact us on COSSIGA.COMPage 8

REAR VENTILATION

Ambient air intake throughright rear

Exhaust air extract throughleft rear internally ducted to envionment

Rear intake and extract ventilation system Side mounted compressor

Front can be fully covered with custom panel joinery to suit environment

Rear Ventilation

A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed hard up against a wall

Separation To Wall

Standard Configuration as shipped

Rear grill removed and replaced with solid panel

Standard rear grill Standard front baffle

Front baffle panel removed and discarded

Front grill detached and re-attached after configuration change

Air flow intake from left rear side and exhaust through right rear side

Optional Configuration - Front to Front

Air flow intake from left front side and exhaust through right front side

Download C.A.D models or contact us on COSSIGA.COMPage 9

CD5 OPTIONAL FRONT VENTING

Back to back with front venting

Against a wall with front venting

Download C.A.D models or contact us on COSSIGA.COMPage 10

PLACEMENT GUIDES

Blocked air flow will retard operation on both HOT and COLD units

Ensure trays or plates are not blocking air flow at rear

CORRECT AIR FLOW INCORRECT AIR FLOW

CLEAR FLOW AIR FLOW BLOCKED

too much chilled airaround coil can createexcessive ice build up

NO AIR FLOW

Mechanical air flows, such as diffusers and fans can disturb the air curtain on open fronted units causing failure

Heat from other equipment and natural conditions, such as direct sunlight straight on units, can cause cooling to fail and over compressor

Natural disruptive air flow suchas cross winds can disturb the air curtain on open frontedunits causing cooling to fail

Locations to avoid :

- Close to shop front exterior - In a high wind- In an outsdie location - Near any source producing excessive heat- In direct sunlight - Service units more frequently in dusty or polluted areas

Download C.A.D models or contact us on COSSIGA.COMPage 11

PLACED IN BENCH DETAIL

Dropped Into Benchtop

Placed Into Benchtop from rear

Parts removed

MODEL CUT OUT SIZE

CD5 6 615 X 720

CD5 9 915 X 720

CD5 12 1215 X 720

CD5 15 1515 X 720

SupportSupport

Support

Unit is dropped in to hole cut in bench top and supported by font and rear flange of unit.

Unit is slid into custom built frame from rear and supported by the sides of the unit base frame. L shaped supports shown in red in this example.Castors, front and side panels removed.

Rear panels / grill remain for personnel safety.

Download C.A.D models or contact us on COSSIGA.COMPage 12

Easy install option to eliminate a nib wallSimply roll in and clip on

Clip on panels offered in routed 18mm MDFMelteca finish in three colour options600/900/1200/100 lengths options with end panels

Affinity Maple

Bliss Shitake

Burnished Wood

COPS CLIP ON PANEL SYSTEM

Download C.A.D models or contact us on COSSIGA.COMPage 13

Bottom edge sits flush with bottom of panel

Double sided velcro

Clips screw fixed topanel

end panels

Integrated Clip System - Bracket fixing to joinery panels

COPS CLIP ON PANEL SYSTEM

Download C.A.D models or contact us on COSSIGA.COMPage 14

CD5 SELF SERVICE SYSTEM

SELF SERVICE SYSTEM

Each unit is self containedRoll-in - Roll-outInstall in minutesNo on site joinery work requiredEase of cleaning and servicingMobile and flexibleEasy to upgrade front panel designCustom branding stripRear service or against wallAll parts as optional component kitsIdeal solution for temporary events

Optional bottom shelf kit for chilled unitsEnsure chilled units are kept well ventilated

Vent required through front panel

Optional bottom meltica shelf kit - BY OTHERS

Optional rear loading shelf kit 200mm deep

Optional bottom meltica shelf kit - BY OTHERS

Download C.A.D models or contact us on COSSIGA.COMPage 15

CD5 ACCESSORIES

Top Mounted Controller Panel

Price Tabs

For against wall installationsSold individually

Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20

Front and Rear Work ShelvesStainless SteelSold individually

Front

Rear

600 - 900 mm - 1200 mm - 1500 mm

600 - 900 mm - 1200 mm - 1500 mm

300 mm

250 mm

Castor Extension Kit

370

mm

280

mm

90 m

m

Increases cabinet height to 1660mm

Set of four, uses existing castors, includes fixing bolts and washers

Base Tray - Heated Units

Tong Holder

Bag Holder

Humidity Dish

100 mm

190 mm

80 mm

180

mm

220 mm

190 mm

105 mm

75 mm

Stainless SteelDrop into counter tray raceSold individually

Stainless SteelFor heated unitsSold in pairs

Stainless SteelPerforated lid is removable

Download C.A.D models or contact us on COSSIGA.COMPage 16

TICKET STRIP

Price TabsLengths

Ticket Strip

Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20

Stainless SteelFits over front of shelves

CABINETLENGTH MM

TICKET STRIP LENGTH

600 475

900 775

1200 1075

1500 1375

End Profile

Download C.A.D models or contact us on COSSIGA.COMPage 17

MERCHANDISE TRAY

Merchandise TrayClip on stainless steel tray for allfree standing units

Attached to front of unitBuilt in ticket stripAngled base for maximum display

Download C.A.D models or contact us on COSSIGA.COMPage 18

Charcuterie RackStainless steel heavy duty shelf brackets 3 x 20 dia Stanless steel tubes

190mm190mm

Replaces existing shelves to allow hanging of cured meats, cheeses etc.Available in 900 and 1200 lengths onlyMaximum of 50kgsHooks not included

Weight to be spread evenly over front, middle and rear

rods

CHARCUTERIE RACK

Download C.A.D models or contact us on COSSIGA.COMPage 19

MIRROR FILM

Applied to the inside glass rear doors

Suitable for heated and chilledunits

Mirror film adhered to inside of rear door glass

Mirror film adhered to inside of rear door glass

FREE STANDING UNITS BENCHTOP UNITS

Blocks work areasbehind units

Add depth toyour displays

Download C.A.D models or contact us on COSSIGA.COMPage 20

CD5 SHELVINGGlass Shelf Options

MODEL GLASS 1ST SHELF DIMENSIONS

2ND SHELFDIMENSIONSBOTTON SHELF MM

3RD SHELFDIMENSIONS

4TH SHELF DIMENSIONS

DEPTH[MM]

LENGTH[MM]

PANESPER SHELF

DEPTH(MM)

LENGTH (MM)

PANES PER SHELF

DEPTH (MM)

LENGTH (MM)

NO. OF PANES

DEPTH (MM)

LENGTH (MM)

NO. OF PANES

CD5RF9 6MM TOUGHENED 350 490 2 390 490 2 440 490 2

CD4RF12 6MM TOUGHENED 350 540 2 390 540 2 440 540 2

CD5RF15 6MM TOUGHENED 350 690 2 390 690 2 440 390 2

CD5HT* 6MM TOUGHENED 320 490 2 360 490 2 400 490 2 450 490 2

CC5HT12 6MM TOUGHENED 330 540 2 360 540 2 400 540 2 450 540 2

CD5HT15 6MM T(OUGHENED 320 690 2 360 690 2 400 690 2 450 690 2

Pie Trays

PIE TRAYS

MODEL NO. OF SHELF TRAYS

WIDTH MM

1ST SHELFDEPTH MM

2ND SHELFDEPTH MM

3RD SHELFDEPTHMM

4TH SHELFDEPTHMM

TOTALTRAYS

CD5HT9 6 PER SHELF 130 325 365 445 465 24

CD4RF12 9 PER SHELF 130 325 365 445 465 32

Standard wire racks are removed and replaced with 6mm toughened glass panes

Stainless Steel glass shelf support bracket

Stainless Steel Construction

1 Rack 1x 1/1 pan One rack with full size pan

1 Rack 1 RackOne rack with drop in divider

1 Rack 2 x 1/2 pan One rack 2 x half pans

1 Rack 5 x 1/9 pans 3 x 16 pansOne rack varrious size pans with divider

GASTRONORM PAN SYSTEM

MODEL PAN DEPTH RACKS NO.

CD5 6 65MM 1X 1/1

CD5 9 65MM 2 X 1/1

CD5 12 65MM 3 X 1/1

CD5 15 65MM 4 X 1/1

Download C.A.D models or contact us on COSSIGA.COMPage 21

GASTRO PAN RACK

Download C.A.D models or contact us on COSSIGA.COMPage 22

- COUNTER TOP MODEL - CURVED OR SQUARE

FREE STANDING - CURVED OR SQUARE

WRAP TRIMMINIG

FREE STANDING BEHIND NIB WALL - CURVED OR SQUARE

DROP IN COUNTER TOP MODEL - CURVED OR SQUAREall exterior visible areas covered

all exterior visible areas covered all exterior top visible areas covered

all exterior top visible areas covered

2mm gap left around rear frame

Rear of units cut around serial number plate, exhaust fan and controller

COLOUR WRAP OPTIONS