CUSP 4 MVP – VAPImproving Care for Mechanically Ventilated Patients
Lung Protective Tidal Volume VentilationBrad Winters, MD, PhD
ARMSTRONG INSTITUTE FOR PATIENT SAFETY AND QUALITYJohns Hopkins University
June 2, 2015
![Page 2: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/2.jpg)
2 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
CUSP 4 MVP – VAP
Comprehensive Unit-based Safety Program for Mechanically Ventilated Patients and Ventilator-Associated Pneumonia
![Page 3: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/3.jpg)
3 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Polling Question
Who is on the call? • IP – infection preventionist• RN – registered nurse• RT – respiratory therapist• PT – physical therapist• OT – occupational therapist• MD – medical doctor• Patient safety professional• Healthcare executive• Educator• National project team• Other
![Page 4: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/4.jpg)
4 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Disclosure
No relevant disclosures
![Page 5: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/5.jpg)
5 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
History Review
• Hunter (1776) developed a double bellows system that pushed and pulled air in and out of lung. Used on dogs with tubes going into trachea
• In 1837, efforts like Hunter lost favor as chest compressions became preferred method (not CPR)
• Both positive and negative pressure systems continued to be developed
• French Academy of Sciences reported that positive pressure (bellows) caused what we now know as barotrauma– Pneumothorax, rupture of alveoli, emphysema
![Page 6: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/6.jpg)
6 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Negative pressure ventilation became the preferred approach ultimately resulting in the Iron Lung.
![Page 7: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/7.jpg)
7 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
• Positive pressure vents still progressed• Draegar (1911) developed the portable Pulmomotor
![Page 8: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/8.jpg)
8 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Endotracheal Intubation
• Uncommon and considered inappropriate outside of OR
• Polio epidemics in the 1950’s outstripped the supply of iron lungs, returning attention to the use of PPV in other settings
• Early PPV used masks• Soon the transition to endotracheal tubes in
conjunction with PPV outside the OR accelerated
![Page 9: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/9.jpg)
9 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
1950’s
• Despite progress, ventilators were still crude• Difficult for precise control of volume and
pressure• 2 primary modes were used:
– Volume regulated– Pressure limited
![Page 10: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/10.jpg)
10 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Ventilator Progress
• 1960s though 1970s
– Ventilation was primarily volume controlled
– Ventilation was completely independent of patient’s pulmonary mechanics
• 1970s through 1980s
– Led to patient triggered modes such as SIMV
– Then to great variety of modes now available
![Page 11: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/11.jpg)
11 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Ventilator Modes forCUSP4MVP–VAP Project
![Page 12: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/12.jpg)
12 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Traditional Ventilation Strategies
Study showed development of hypoxia in surgical patients when lower ventilation was provided.
Perhaps the best course of action during controlled ventilation is to imitate nature quite closely in providing reasonably large tidal volumes at a respiratory rate not exceeding 14 to 16 per minute, and also in providing periodic passive hyperinflation of the lungs, thus replacing the lacking spontaneous deep breaths, or sighs. It might even be desirable if mechanical respirators were able to “sigh” automatically.
–– 1Bendixen, NEJM, 1963
“
”
![Page 13: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/13.jpg)
13 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Traditional Ventilation Strategies
• Since atelectasis is undesirable (shunt, hypoxia), a large tidal volume approach became the norm– 10–15 cc/kg – Disseminated by most Anesthesiology textbooks
• Evidence of oxygen toxicity made physicians reluctant to use high FIO2
![Page 14: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/14.jpg)
14 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Problem with Large Tidal Volume (Vt)
• In acute lung injury there is a breakdown in lung architecture and capillary leak
• Leads to stiff lungs with areas of over-inflation and under-inflation
• Large Vt results in over-distension of some areas resulting in ”volutrauma” – Considered major cause of ventilator-associated
lung injury• Leads to inflammatory responses that further
damage the lung(s)
![Page 15: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/15.jpg)
15 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Problem with Large Tidal Volume (Vt)
• Can also lead to barotrauma– Rupture of alveoli– Pneumothorax
• Some airspaces collapse, then re-open cyclically – Shear stresses as alveoli close and “pop” open
• Clear that commonly used tidal volumes were injurious to the lung
• Researchers proposed using lower tidal volumes and allowing mild to moderate respiratory acidosis to improve outcomes
![Page 16: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/16.jpg)
16 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Based on animal studies and some small clinical studies, the “ARDSNET” Trial (2000, NEJM) compared outcomes using traditional tidal volumes (>10 cc/kg) to lower volumes (4–6 cc/kg) finding significant benefit.
Probability of Survival and Discharged Home
2The Acute Respiratory Distress Syndrome Network. N Engl J Med 2000;342:1301-8.
![Page 17: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/17.jpg)
17 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Primary Findings2
VARIABLE
GROUP RECEIVING
LOWER TIDAL
VOLUMES
GROUP RECEIVING
TRADITIONAL TIDAL
VOLUMES P VALUE
Death before discharge home and breathing w/o assistance (%) 31.0 39.8 0.007
Breathing without assistance by day 28 (%) 65.7 55.0 <0.001
No. of ventilator-free days, days 1 to 28 12±11 10±11 0.007
Barotrauma, days 1 to 2810 11 0.430
No. of days w/o failure of nonpulmonary organs or systems, days 1 to 28
15±11 12±11 0.006
Plus–minus values are means ±SD. The number of ventilator-free days is the mean number of days from day 1 to day 28 on which the patient had been breathing without assistance for at least 48 consecutive hours. Barotrauma was defined as any new pneumothorax, pneumomediastinum, or subcutaneous emphysema, or a pneumatocele that was more than 2 cm in diameter. Organ and system failures were defined as described in the Methods section.
![Page 18: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/18.jpg)
18 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
LTVV in ARDS
• Large Vt and the high pressures it generates were harmful3,4
• LTVV became the mainstay of ARDS management– Ventilate with Vt of 6–8 cc/kg PBW
– Originally was as low as 4–6 cc/kg– Plateau pressures should be measured, documented and targeted
to be no more then 30 cm H20 (too difficult to measure trans-pulmonary pressures clinically).
– PEEP/FIO2 escalation/de-escalation algorithm
PBW = Predicted Body WeightIt is based on weight and gender.
3Putensen 20094Girard, Bernard 2007
![Page 19: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/19.jpg)
19 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Beyond ARDS?Emerging Evidence5
Multi-hit theory• Priming: Initial insult (PNA, sepsis, trauma, non-cardiogenic shock,
multiple transfusions, CPB) = At Risk for ARDS
• Large Vt and transpulmonary pressures amplification of SIRS + ventilator induced lung injury (iatrogenic ARDS)
5Lellouche, Intensive Care Med (2013)
![Page 20: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/20.jpg)
20 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Periop5
5Lellouche, Lipes, 2013
![Page 21: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/21.jpg)
21 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
ICU Patient Results5 (not all are perioperative)
5Lellouche and Lipes, 2013
![Page 22: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/22.jpg)
22 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Meta-analysis of LTVV in patients w/o lung injury6
6Neto et al., 2012
![Page 23: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/23.jpg)
23 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Meta-analysis of LTVV in Patients w/o Lung Injury6
6Neto et al., 2012
![Page 24: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/24.jpg)
24 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
LTVV in Patients w/o Lung Injury6
Lung InjuryNNT = 11Fixed effects model
FAVORS LOW VT FAVORS HIGH VT
![Page 25: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/25.jpg)
25 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
LTVV in Patients w/o Lung Injury6
Pulmonary InfectionNNT = 26 Random effects model
Favors low Vt Favors high Vt
FAVORS LOW VT FAVORS HIGH VT
![Page 26: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/26.jpg)
26 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
LTVV in Patients w/o Lung Injury6
Atelectasis
Favors low Vt Favors high Vt
FAVORS LOW VT FAVORS HIGH VT
![Page 27: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/27.jpg)
27 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
LTVV in Patients w/o Lung Injury6
MortalityNNT = 23Fixed effects modelAdditionally they found significantly lower mean (SD) hospital LOS (6.91 [2.36] vs. 8.87 [2.93] days, but no significant change in ICU LOS
FAVORS LOW VT FAVORS HIGH VT
![Page 28: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/28.jpg)
28 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Focusing on ICU Patients Only
• Acute Lung Injury– 3 trials with 691 patients– RR = 0.33 95% CI 0.21–0.51 p=0.001
• Mortality– 3 trials with 561 patients – RR = 0.57 95% CI 0.38–0.84 p=0.005
• Pulmonary Infection– 1 trial with 103 patients– RR = 0.20 95% CI 0.04-0.99 p=0.05
![Page 29: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/29.jpg)
29 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Quality Gap
• Large Vt still commonly used in ICUs5
– Up to 18 cc/kg PBW
• Pulmonary damage shown to occur within a few hours of MV7
• Clinicians often miss early or mild ARDS or fail to appreciate the at-risk patient quality gap8
5Lellouche et al., 20127Zupancich et al., 20058Herasevich, 2011
![Page 30: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/30.jpg)
30 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Preemption
• Why wait?• Why not initiate LTVV on
all patients to minimize risk?
• Too late once ARDS/ALI criteria is met
• A few hours of mechanical ventilation with large Vt may start the cascade
![Page 31: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/31.jpg)
31 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Low Tidal VolumeImplementation
• Patients at risk of ARDS should be ventilated with a Vt between 6–8 ml/kg PBW
• Patients without risk factors should be ventilated with a Vt <10 ml/kg PBW
![Page 32: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/32.jpg)
32 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Use PBW Rather than ABW
• PBW based on gender and height• For BMI > 25, ABW will lead to incorrect Vt and is
associated with increased organ failure5
5Lellouche et al., 2012
![Page 33: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/33.jpg)
33 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
What about PEEP?
• Bendixen was right => Low Vt does cause atelectasis
• PEEP counteracts this tendency, especially in obesity
• Prevents “volutrauma”
• Use ARDSNet protocol if ARDS is diagnosed, but many use higher values
• 8–12 cm H2O PEEP is used in many studies of pre-emptive low Vt, but many also use 5–8 cm H2O
![Page 34: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/34.jpg)
34 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
What about PEEP?
• Unclear optimal level in non-ALI patients • Clear that should not use ZEEP
– ZEEP is considered PEEP < 5– Associated with negative outcomes9,10
• Hypoxia• VAP• Increase mortality
9Metnitz PG et al., 2009; 10Manzano et al., 2008
![Page 35: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/35.jpg)
35 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Respiratory Rate
• Using Low Vt requires increased respiratory rates to prevent excessive hypercarbia
• Permissive hypercapnia (PCO2 in the 50’s)– Usually tolerated well unless there is also a
severe metabolic acidosis• Maintain minute ventilation as best possible• May need to increase to 30 cm H2O or more
• Downsides with these high rates include breath-stacking and high auto-PEEP
![Page 36: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/36.jpg)
36 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Plateau Pressure
• Need to keep <30 cm H2O
• To achieve, Vt may need to be dropped further depending on compliance
• Bronchodilators, sedation or rarely paralysis may be necessary
• Sedation and paralysis should be used very sparingly, especially paralytics
![Page 37: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/37.jpg)
37 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Barriers to Low Vt Implementation
• Translation of evidence into practice is difficult
• Only 46% of eligible patients received LTVV 8 years after ARDSNET trial11
• Application to non-ALI patients is not well known, but likely much lower nationally
11Umoh et al. (2008)
![Page 38: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/38.jpg)
38 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
Summary
• LTVV– Yes for patients with acute lung injury (ALI)
– Probably yes in non-ALI ICU patients
• Current recommendations– At least <10 mL/KG PBW; 6–8 mL/KG preferred
– PEEP ≥ 5 cm H2O
![Page 39: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/39.jpg)
39 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
![Page 40: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/40.jpg)
40 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
References
1. Bendixen HH, Hedley Whyte J, Laver MB. Impaired oxygenation in surgical patients during general anesthesia with controlled ventilation. N Engl J Med. 1963;269:991-6. PMID: 14059732.
2. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. The Acute Respiratory Distress Syndrome Network. N Engl J Med. 2000;342(18):1301-8. PMID: 10793162.
3. Putensen C, Theuerkauf N, Zinserling J, Wrigge H, Pelosi P. Meta-analysis: ventilation strategies and outcomes of the acute respiratory distress syndrome and acute lung injury. Ann Intern Med. 2009;151(8), 566-76. PMID: 19841457.
4. Girard TD, Bernard F=GR. Mechanical ventilation in ARDS: a state-of-the-art review. Chest. 2007;131(3), 921-9. PMID: 17356115.
5. Lellouche F, Lipes J. Prophylactic protective ventilation: lower tidal volumes for all critically ill patients? Intensive Care Med. 2013;39(1), 6-15. PMID: 23108608.
6. Serpa Neto A, Cardoso SO, Manetta JA, Pereira VG, Esposito DC, Pasqualucci Mde O, Damasceno MC, Schultz MJ. Association between use of lung-protective ventilation with lower tidal volumes and clinical outcomes among patients without acute respiratory distress syndrome: a meta-analysis. JAMA. 2012;308(16), 1651-9.
![Page 41: CUSP 4 MVP – VAP Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation Brad Winters, MD, PhD ARMSTRONG INSTITUTE](https://reader036.vdocument.in/reader036/viewer/2022062516/56649e4a5503460f94b3e072/html5/thumbnails/41.jpg)
41 CUSP 4 MVP – VAP: Improving Care for Mechanically Ventilated Patients Lung Protective Tidal Volume Ventilation
References
7. Zupancich E, Paparella D, Turani F, Munch C, Rossi A, Massaccesi S, Ranieri VM. Mechanical ventilation affects inflammatory mediators in patients undergoing cardiopulmonary bypass for cardiac surgery: a randomized clinical trial. J Thorac Cardiovasc Surg. 2005;130(2), 378-83. PMID: 16077402.
8. Herasevich V, Tsapenko M, Kojicic M, Ahmed A, Kashyap R, Venkata C, Shahjehan K, Thakur SJ, Pickering BW, Zhang J, Hubmayr RD, Gajic O. Limiting ventilator-induced lung injury through individual electronic medical record surveillance. Crit Care Med. 2011;39(1):34-9. PMID: 20959788.
9. Metnitz PG, Metnitz B, Moreno RP, Bauer P, Del Sorbo L, Hoermann C, de Carvalho SA, Ranieri VM; SAPS 3 Investigators. Epidemiology of mechanical ventilation: analysis of the SAPS 3 database. Intensive Care Med. 2009;35(5), 816-25. PMID: 19288079.
10. Manzano F, Fernández-Mondéjar E, Colmenero M, Poyatos ME, Rivera R, Machado J, Catalán I, Artigas A. Positive-end expiratory pressure reduces incidence of ventilator-associated pneumonia in nonhypoxemic patients. Crit Care Med, 2008; 36(8), 2225–31. PMID: 18664777.
11. Umoh NJ, Fan E, Mendez-Tellez PA, Sevransky JE, Dennison CR, Shanholtz C, Pronovost PJ, Needham DM. Patient and intensive care unit organizational factors associated with low tidal volume ventilation in acute lung injury. Crit Care Med. 2008;36(5), 1463-8. PMID: 18434907.
12. Levin MA, McCormick PJ, Lin HM, Hosseinian L, Fischer GW. Low intraoperative tidal volume ventilation with minimal PEEP is associated with increased mortality. Br J Anaesth. 2014;113(1), 97-108. PMID: 24623057.