Power IT Cooling Cut your data center project time from years to months. Now you can, with prefabricated data center solutions that simplify your entire project experience. Use our library of more than 100 reference designs to start your project. Faster deployment Flexibility and scalability TM Business-wise, Future-driven. Predictable performance

Upload: ngodieu

Post on 22-Mar-2018

228 views

Category:

Documents


2 download

TRANSCRIPT

Power IT Cooling

Cut your data center project time from years to months.Now you can, with prefabricated data center solutionsthat simplify your entire project experience.

Use our library of more than 100reference designs to start your project.

Faster deployment

Flexibility andscalability

TMBusiness-wise, Future-driven.

Predictableperformance

Learn how to get predictable performanceand quick, easy deployment today!

The Global Leader in Energy Managementwww.schneider-electric.com

PrefabricatedData Center ModulesStand-alone modules or 90 kW to 2 MWfully prefabricated data center solutions

NON ISO modular Data Center

IS YOUR NEXT DATACENTER

GOING TO BE MODULAR?

Containerized Data Centers Data Center Cooling Modules

PORTABLE RUGGED AND ENERGY

EFFICIENT.

DIRECT OR INDIRECT FREE

COOLING?

The Global Leader in Energy Managementwww.schneider-electric.com

Prefabricated Data Center Modules

Challenges

You need to deploy a data center that has predictable performance, fast deployment, flexibility and scalability. You need additional power, cooling or IT space but are challenged by your location, timing or financial constraints.

SolutionsSchneider Electric offers a broad range of Prefabricated Data Center Modules comprised of All-in-One configurations, Power skids and modules, Cooling and Hydronics modules, and IT modules. Prefabricated Data Center Modules allow the planning cycle to switch from an onsite construction focus to onsite integrations of these prefabricated building blocks.

Prefabricated Data Center Module benefits:

• Pre-engineered and wired with integrated hardware and software, manufactured and tested in a factory

Arrives on-site ready to deploy quickly and easily

Enables a new-generation of data centers with multiple levels of densities, criticalities and voltages

Multiple form factors and power ranges, inside or outside deployment

Building Blocks used independently or together to form a data center solution

The Global Leader in Energy Managementwww.schneider-electric.com

Concerns over power and space limitations, capital and operational expenditures can be now addressed through containerized datacenter. AST Modular manufactures rugged, portable and energy efficient containerized datacenters that provide plug & play datacenter capacity inside an ISO container in a fast and cost effective way. Vendor neutral and deployable in virtually any environment, AST Modular containers are available as all-in-one compact units providing a fully functional data center in a pod in standard models of 20’ 40’ and 53’. They are also available as standalone power, cooling and IT units and can, upon request, be combined and customized for large scale container farms deployments.

Containerized Data CentersRugged & Energy Efficient

Compact all-in-one Container Direct Free Cooling ContainerContains all required components for data centre operation DFC module uses outdoor air to cool DC when suitable outdoor temp & Thermally insulated and can withstand temperatures ranging humidity existfrom -50 to +150 C Requires support of chiller of cooling tower for when conditions are not N+1 Power and cooling suitableIdeal for deployment in remote locations In the right environment can bring massive energy savingsIdeal mobile contingency for disaster recovery Can be used to cool IT services container of brick and mortar DC.Provides additional capacity when plant and rack space is at its limits Chilled Water Block ContainerUp to 19 x 42u Server cabinets Provides and alternative to rack cooling plantUp to 750kW of power and cooling in 320sqft Used in conjunction with IT services and Stand alone container

Can be used to provide additional cooling to brick and mortar DCIT Standalone Container Requires chiller, cooling tower or dry cooler.

Up to 19 x 42u Server cabinets Used in conjunction with services support container Power ContainerUp to 750kW of power and cooling in 320sqft Power upgrades in existing data centers.N+1 Cooling and power distribution Deployable outdoors.Suitable for use with containerized cooling such as NFC & CW Future reutilization.block Ideal for mobile contingency.

Natural Free Cooling Container Containerized Vestibule

Provides an alternative to all cooling plant Entry area for IT services moduleHighly energy efficient Additional protection for IT hardware when deployed in desert or arctic Used with IT services container it can provide 400kW of environmentcooling Cab be fitted with an airlockCan be used to provide cooling to brick and mortar DC Can be fitted with work station to provide local consol access to IT

• ••

••• •• ••

• •• •

••

••• •• •• •

• •• ••

•• •

Container Farms

Range of Containers

Alternative thinking for large data centres Multiple types cooling technology can be deployed simultaneouslyMultiple containers working together Easy mixing of high and low density areasConsisting of rack modules, cooling modules, services No requirement for a buildingmodules, generator modules and vestibule modules Containers can be stacked vertically drastically reducing required areaEnables a defined building block approach to DC expansion Enables rapid deployment and expansion

•• •• •

•• •

Overview

The Global Leader in Energy Managementwww.schneider-electric.com

Data Center Cooling ModulesEnergy Efficiency at its finest.

Natural Free Cooling

Natural Free Cooling is AST Modular's propretary indirect free cooling technology that through a passive air to air heat exchanger leverages temperature differences between outside cold air and hot air coming from the servers. NFC provides multiple types of economization as it is capable to select between air-to-air, adiabatic and traditional cooling to cool the data center in the most efficient way.

Direct Free Cooling

Direct Free Cooling Modules are a cooling solutions able to leverage outdoor fresh air by driving it from the outside to the inside of the data center. Direct Free Cooling generates significant savings since in certain locations data centers operators can take full advantage of free cooling for several hours of the day without the need of expensive mechanical cooling.

Chilled Water Block

Chilled Water Block Modules are a water based datacenter cooling technology whose water coil surface is extended compared to the one of a traditional Computer Room Air Conditioning (CRAC). The extended cooling surface of the coil allows the chiller to supply water at higher temperatures thus resulting in improved energy efficiency.

Hot Corridor Exchanger

HCX Modules are a water based overhead cooling technology composed of variable-speed fans and a water coil whose surface is bigger than the one of nn row cooling technologies. The extended surface of the coil allows the chiller to supply water at higher temperatures, thus resulting in improved energy efficiency. HCX Modules are a compact solution specifically suitable for all environments where IT space is at a premium.

AST Modular has engineered 4 ultra energy efficient cooling solutions applicable to both modular and traditional datacenters to reduce energy consumption and improve datacenter footprint.

The Global Leader in Energy Managementwww.schneider-electric.com

Natural Free CoolingSecure and Ultra Energy Efficient Indirect Free Cooling

TECHNOLOGY

Natural Free Cooling, a worldwide patented AST Modular’s technology, is indirect air to air and adiabatic cooling solution that leverages temperature differences between outside cold air and hot air coming out of the servers. Thanks to its heat pipe exchanger technology and the intelligent control system NFC provides multiple types of economization. Natural Free Cooling can select between air-to-air, adiabatic and mechanical cooling to run your mission critical applications in the most efficient way.

MULTI ECONOMIZATION EXPLAINED

NFC capitalize free cooling at 100% with dry bulb temperatures below 20° C/68 F. They operate with adiabatic cooling with wet bulb temperatures below 20 ° C/68 F and are supported by a traditional datacenter chiller when ASHRAE’s temperature and humidity ranges cannot be met, specifically with wet bulb temperatures above 20° C/68 F. Unlike direct free cooling systems, NFC Modules are the first solution in the market able to prevent cross contamination and humidity within the datacenter. The exhaust air coming from the servers is cooled inside segregated chambers and no outdoor air is introduced into the IT space. As a result the datacenter remains as a sealed enclosure, unaffected by external conditions such as humidity, pollution, corrosive gases, and particles. This approach drastically reduces filter, maintenance, and fan power costs, thus resulting in added security, resiliency and much better energy efficiency than direct free cooling technologies.

MODULARITY

Natural Free Cooling is available in 50kw individual modules. This scalable approach enables the customer to purchase only the cooling capacity needed to meet current requirements. Additional NFC modules can be added as the data center load grows.

The Global Leader in Energy Managementwww.schneider-electric.com

Direct Free CoolingReduce chillers usage

TECHNOLOGY

Direct Free Cooling Modules are a cooling solutions able to leverage outdoor fresh air by driving it from the outside to the inside of the data center. Direct Free Cooling generates significant savings since in certain locations data centers operators can take full advantage of free cooling for several hours of the day without the need of expensive mechanical cooling. Indeed the back-up cooling support embedded into DFC Modules is activated only when ASHRAE recommended temperature levels cannot be met and specifically beyond 27°C/80.6F external dry bulb temperature.

OPERATIONS

Phase 1External Temperature < 18ºC/64.4F. The dampers of DFC Modules mix the outside fresh air with the hot air coming from the datacenter to achieve thecorrect supply conditions. The outside air is filtered before entering the IT area. Filtering is performed accordingto site conditions and the level of security required and part of the air coming from the datacenter is exhausted towards the outside with intake air pressure given by the fan. Variable speed fans together with dampers match the airflow needed to cool the datacenter to the temperature required. Phase 218ºC/64.4F < External Temperature < 27ºC/80.6F. The outdoor air is blown into the cold corridor and no outside air is mixed with the hot air coming from thedatacenter. The whole of the hot air coming from the servers is exhausted towards the outside with intake air pressure given by the fan. Variable speed fans match the airflow needed to cool the datacenter to the temperature required. The maximum external temperature allowed inside the cold corridor varies upon design conditions and compliance with ASHRAE limits. Phase 3External Temperature > 27ºC/80.6F No free cooling is available, hence the mechanical support cooling system is in use. The system recirculates the air from the hot to the cold corridor and cools down the servers to the desired temperature and upon design conditions.Two cooling systems are available: Chilled water (CW) or Direct expansion (DX). Variable speed fans match the airflow needed to cool the datacenter to the temperature required.

MODULARITY

DFC Modules are available in 50kw individual modules. This scalable approach enables the customer to purchase only the cooling capacity needed to meet current requirements. Additional DFC units can be added as the data center load grows and installed in a “live environment” without disruption to the service.

The Global Leader in Energy Managementwww.schneider-electric.com

Chilled Water BlockEnhanced Chilled Water Effiiciency

TECHNOLOGY

Chilled Water Block Modules are a water based datacenter cooling technology whose water coil surface is extended compared to the one of a traditional Computer Room Air Conditioning. The extended cooling surface of the coil allows the chiller to supply water at higher temperatures thus resulting in improved energy efficiency.

MAIN COMPONENTS

Variable Speed FansWater CoilFree cooling chiller or evaporative Cooling Tower (optional)Humidifier (optional)

MODULES

CWB Modules are available in 100 KW and 150 KW models. This scalable approach enables the customer to purchase only the cooling capacity needed to meet current requirements. Additional CWB modules can be added as the data center load grows and installed in a ‘live environment’ without disruption to the service.

The Global Leader in Energy Managementwww.schneider-electric.com

Hot Corridor Exchanger

TECHNOLOGY

HCX Modules are a water based overhead cooling technology composed of variable-speed fans and a water coil whose surface is bigger than the one of In Row Cooling units. The extended surface of the coil allows the chiller to supply water at higher temperatures, thus resulting in improved energy efficiency. Dependent upon design conditions the water can be supplied up to 17°C/62.6F. Originally engineered for containerized datacenters HCX Modules are a compact solution specifically suitable for all data center environments where valuable IT space is a critical business requirement and specifically modular datacenters.

OPERATIONS

Hot Air comes from the serversHot air is ducted through the coilHot Air is cooled down by the coilCold Air is blown back into the servers

MODULES

HCX Modules are available in the following 7,5 Kw/Rack and 20 Kw/Rack modules. This scalable and approach enables the customer to purchase only the cooling capacity needed to meet current requirements. Additional HCX Modules can be added as the data center load grows and installed in a “live environment” without disruption to the service.

The Global Leader in Energy Managementwww.schneider-electric.com

Hot Corridor Exchanger

NON ISO Modular Datacenter

NON ISO Modular Data Center is a purpose-engineered system designed to offer scalable data center capacity. Available in two standard sizes of 25’ and 45’ and with multiple power and cooling options, NON ISO MDC is suitable to green field datacenter deployments and can also be integrated into your existing data center facilities. Off site constructed, MDC can be delievered at your premises as all-in-one compact modules or in multiple configuration to achieve state of the art contiguous datacenter white space in a matter of weeks.

BENEFITS

• Reduced Capex.Thanks to its design, a modular datacenter can easily scale along with your business needs, allowing for additional data center capacity to be deployed as needed. The build as you need approach minimizes the upfront CAPEX required when building a traditional data center.Fast Deployment. MDC can now procure a modular data center in a fraction of the time required to design and build a traditional data center or retrofit an existing one.Real Estate Savings. Save valuable real estate space since MDC can be deployed anywhere - i.e. a parking lot or inside a warehouse - and only require a temporary building permit, thus simplifying complexity and risks associated to project delivery.Energy Efficient. MDC achieves very low PUE levels thanks to state of the art AST Modular cooling technologies such as Natural Free CoolingRelocatable & Fully Integrated. Unlike brick and mortar data centers, MDC can be relocated as business and IT needs evolve. Our offsite constructed plug & play modules are ready to be installed and include 100% of the datacenter critical infrastructure needed.Flexible & Customizable. MDC is highly flexible and allows for hardware from any manufacturer to be integrated. Different configurations are available and can be customized to meet your datacenter needs.Ideal for High Density Environments. AST Modular MDC is specifically designed to keep the pace with your growing power and cooling needs and changes brought by virtualization & cloud computing.