cyberknife qad3udwuy5vw6moa.cloudfront.net/literature/qa-stereochecker_br_1402-04.pdfthe qa...
TRANSCRIPT
CYBERKNIFE QAF I L M L E S S C Y B E R K N I F E ® Q A S Y S T E M
CY
BE
RK
NIF
E®
IS
A R
EG
IST
ER
ED
TR
AD
EM
AR
K
OF
AC
CU
RA
Y I
NC
OR
PO
RA
TE
D
PAT E N T P E N D I N G
QA STEREOCHECKER™
C Y B E R K N I F E Q A
O n a v e r a g e , t h e a n n u a l c o s t o f f i l m
n e c e s s a r y f o r d a i l y C y b e r K n i f e Q A
t e s t s c a n b e a s m u c h a s $ 5 , 0 0 0 U S D .
T h i s c o s t c a n b e d r a s t i c a l l y r e d u c e d
b y u s i n g t h e Q A S t e r e o C h e c k e r ,
w h i c h d o e s n o t r e q u i r e f i l m .
D I D Y O U K N O W ?
F I D U C I A L SF O R A U T O M A T I C P O S I T I O N I N G
F I L M L E S S C Y B E R K N I F E ® Q A S Y S T E MIntegrated imaging, analysis and reporting for extensive daily CyberKnife QA
The QA StereoChecker makes it easy to give daily CyberKnife QA the attention
it deserves. Designed to be used by both physicists and therapists, the QA
StereoChecker helps you complete your daily CyberKnife QA in a matter of
minutes, enabling improved frequency and depth of your QA practice.
QA STEREOCHECKER™
R E A D Y W H E N Y O U A R E
Simply place the QA StereoChecker on the couch
and position with automatic alignment features.
No film, no bulky collimator attachments, and no
manipulation of the robot required. CyberKnife
uses the same clinical mode to deliver the QA
treatment as it does the real patient treatment.
The QA StereoChecker is aligned using the
fiducials in the phantom, the same system used
to align your patients prior to treatment.
C Y B E R K N I F E Q A
SPEED AND ACCURACY: NOW YOU CAN HAVE BOTHH I G H L Y - A C C U R A T E , R E P E A T A B L E R E S U L T S
IRIS QAThe QASC delivers quantitative results regarding
the field size, flatness, and penumbra for all
clinical iris diameters. An automated analysis
software routine allows for consecutive analysis
of all Iris diameters in a matter of seconds.
Results can be exported as a report, and images
and data can be exported for further analysis.
This monthly test can now be performed on a
daily basis, providing feedback on the status of
each field size, allowing for trends to be observed
and reducing machine downtime.
MLC QAEfficiently (and again without film) perform a
garden fence or picket fence test. The QASC
software can detect leaf errors to within 0.2 mm,
prevent machine downtime and improving
throughput. Seamlessly integrate this device
with the latest offerings of the MLC dose
delivery techniques.
POSITION AND DELIVERY ANALYSIS (PANDA)Eliminate film from your daily QA routine! The
automated TLS/TDS analysis algorithm (PANDA)
verifies the performance of positioning and
delivery. The QASC can detect and report on
translational errors in three dimensions to within
0.1 mm. In less than ten minutes, perform an
analog to the manufacturer-recommended
automated quality assurance test, and save your
results as a report or export data and images.
T h e Q A S t e r e o C h e c k e r u s e s t h e s a m e
t y p e o f h i g h r e s o l u t i o n d e t e c t o r s
a s o n - b o a r d i m a g i n g s y s t e m s o f
t r a d i t i o n a l l i n a c s ( s u c h a s E P I D s ) t o
g i v e y o u h i g h l y - a c c u r a t e , r e p e a t a b l e
r e s u l t s i n r e c o r d t i m e . Yo u c a n c u t
y o u r d a i l y C y b e r K n i f e Q A t i m e f r o m
t w o h o u r s d o w n t o j u s t 1 5 m i n u t e s .
1 5 M I N U T E S
2 H O UR
S
www.standardimaging.com // +1 608 831 0025
C Y B E R K N I F E Q A
QA STEREOCHECKER SPECIFICATIONSDimensions — [ length × width × height ] 38.7 cm x 32.7 cm x 4.9 cm // Photons — 60Co to 15 MV
SensorTotal Pixel Number — 1024 x 1024 // Active Pixel Number — 1000 x 1000 // Pitch — 200 µm // Total Area — 204.8 x 204.8 mm2
DetectorDynamic Range — > 88 dB // Scintillator — Gd2O2S:Tb // Electronics — ADC 16 bit, 1 MSps
Software SpecificationsOperating System — Windows® 10 Professional, 64-bit; English version is required in all casesProcessor — Intel Core (At least dual-core recommended) // Memory — 8 GB RAM (16 GB recommended)Hard Drive — 2 GB Free (20 GB Recommended) // Screen Resolution — 1024 x 768 or higher // Ports — RJ45 (Ethernet)
Windows® is registered trademarks of Microsoft Corporation. Specifications subject to change without notice.
IRIS™ QAC O M P L E T E I N 5 M I N U T E S
• Scan quality data every morning
• Measures profiles, field width, penumbra, flatness
• Capable of detecting a 0.1 mm field size variation
PANDAC O M P L E T E I N 5 M I N U T E S
• Replaces film-based AQA with a faster and easier method, producing equivalent or better results
• Measures translational and rotational offsets in three dimensions
• Capable of detecting a 0.1 mm translational offset
MLC QAC O M P L E T E I N 5 M I N U T E S
• Replaces daily non-quantitative film-based Picket Fence Tests and monthly Garden Fence Tests
• Measures planned vs. acquired leaf patterns
• Capable of detecting leaf variation of 0.2 mm
STREAMLINED OPERATIONC Y B E R K N I F E Q A C A N N O W B E P E R F O R M E D D A I L Y B Y T H E R A P I S T S
We have been very happy with our purchase of the QA StereoChecker.
Since acquiring the QASC, CyberKnife daily and monthly MLC and
Iris QA at our clinic has been a breeze. The ease of use, coupled
with the high resolution, makes me and my therapist’s life so much
easier. We currently do a lot of patient specific SRS/SBRT QA with
film, and having to be largely filmless with machine QA is big deal.
Definitely a worthwhile investment, especially considering the
future potential of this device.”
S I D N E Y N T A Z E H M . S C . , D A B R
CyberKnife Medical PhysicistJames A. Haley VA Medical Center
P A T E N T P E N D I N G
www.standardimaging.com // +1 608 831 0025
C Y B E R K N I F E Q A
www.standardimaging.com800-261-4446 . ph 608-831-0025 . fax 608-831-2202 3120 Deming Way Middleton WI 53562-1461 USA
© 2019 Standard Imaging, Inc. 1402-04 (6.19)